VSW-MC-CTRL MEDIACENTO CONTROLLER · switching is done as well as setting up presets, if desired....
Transcript of VSW-MC-CTRL MEDIACENTO CONTROLLER · switching is done as well as setting up presets, if desired....
STEP X - Name of Step
24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM
VSW-MC-CTRL
MEDIACENTO CONTROLLER
QUICK START GUIDE
STEP 1 - Package Contents
OPTIONAL: DOWNLOAD USER MANUALFor product specifications and regulatory information, refer to the User Manual. You can download this document from our web site.
1. Go to www.blackbox.com
2. Enter the part number (VSW-MC-CTRL) in the search box.
3. Click on the product in the “Product Results” page.
4. Click on the “Support” tab on the product page, and select the document you wish to download.
If you have any trouble accessing the Black Box site to download the manual, you can contact our Technical Support at 877-877-2269 or [email protected]
VSW-MC-CTRL PACKAGE CONTENTS
• (1) MEDIACENTO IPX CONTROLLER
• (1) POWER SUPPLY WITH POWER CORD
• THIS QUICK START GUIDE
ADDITIONAL ITEMS YOU WILL NEED
• MEDIACENTO IPX TRANSMITTERS AND RECEIVERS
STEP 2A - Front Panel of the MediaCento Controller
1
FRONT PANEL
TABLE 1. VSW-MC-CTRL FRONT PANEL COMPONENTS
NUMBER IN DIAGRAM ABOVE DESCRIPTION DESCRIPTION
1 (1) DB9 male connector RS-232 console port
STEP 2B - Back Panel of the MediaCento Controller
2 3 4 5 6 7 8
BACK PANEL
TABLE 2. VSW-MC-CTRL REAR PANEL COMPONENTS
NUMBER IN DIAGRAM ABOVE DESCRIPTION DESCRIPTION
2 (2) USB Type A connectors Links to USB devices
3 (1) RJ-45 connector Links to AV network
4 (1) RJ-45 connector Links to control network
5 (1) HDMI connector HDMI
6 (1) HD15 connector VGA
7 (1) Power LED Lights when power is ON
8 (1) Power connector Connect to 12-VDC power supply
STEP 3 - Log In to the MediaCento IPX Controller
LOGIN STEPSConnect through your preferred Web browser to access the Controller's Web interface in the following ways:
1. If the same Ethernet interface is used for both the MediaCento IPX endpoints and your control PC, you should be connected to Eth1 and you will have access to the default IP address: 169.254.1.1
2. If you are using the optional Control port to control the system from a secondary network, your PC should be connected to Eth0 and you will have to access the default IP address: 192.168.10.10
3. When first connecting to the MediaCento IPX Controller, enter the default username (admin) and password (BBNSMediaCento).
DEFAULT USER NAME AND PASSWORD
• user name: admin
• password: BBNSMediaCento
LOGIN SCREEN
DEFAULT API CREDENTIALS
• user name: apiuser
• password: apipass2015
DEFAULT IP ADDRESS
• default IP address for eth1: 169.254.1.1
• default IP address for eth0: 192.168.10.10
STEP 4 - User Interface Pages
DASHBOARD
VIEW STATUS AND CHANGE PRESETSFrom the Dashboard, you can::
1. Check the status of the controller.
2. See which receiver is currently connected to which transmitter.
3. To change a preset, select the preset in the drop-down menu and confirm the switch.
CUSTOM DISPLAY
CUSTOM DISPLAY
The custom display page is where specific switching is done as well as setting up presets, if desired. The matrix in the middle is easy to use with receivers/groups/and video walls along the left of the matrix and transmitters (sources) along the top.
1. To switch, simply select the box that matches the desired receivers to the correct transmitters and confirm the switch.
2. To set up presets, switch the units to the desired layout, confirm the switch and save the preset. When saving a preset, a name and note can be linked to it for ease of use for all users.
STEP 4 (CONTINUED) - User Interface Pages
GROUPS SCREEN
GROUPS
The groups page is where groups and video walls are created from a number of receivers. 1. To create a group, select the desired receivers and put them into the right column. The group can be named and saved now or turned into a video wall.
2. To create a video wall out of the group, check the video wall checkbox. This will open up an additional window below where you can enter the number of rows and columns, as well as bezel information. You can drag and drop receivers in the group from the list to the left of the video wall diagram. Bezel information is a ratio and units does not matter as long as the same units are used for all bezel information.
VIDEO WALL SCREEN
STEP 4 (CONTINUED) - User Interface Pages
SETTINGS PAGE
SETTINGS
The settings page is where the controller specific settings can be changed. This currently includes the IP addresses of both the control and video networks.
HARDWARE SCREEN
HARDWARE
The hardware page is where new MediaCento IPX units are detected and configuration on them is done. Detecting new units can take up to 30 seconds, but it will find and display every MediaCento IPX unit seen on the network. Receivers are listed on the left and transmitters on the right.
1. Each unit can be given a specific name which is connected to the IP address. This makes it easier to switch correct units.
2. To correctly identify each unit, OSD (On Screen Display) can be triggered. This will display the IP address as well as any name currently given to a receiver on the display it is connected to.
NOTE: For advanced commands, refer to the user manual.
STEP 5 - Application Program Interface (API)
1. To enable API functionality, navigate to the “Settings” tab and check the box under “Enable/Disable API User.” Enabling this setting will allow the default API user of your MediaCento Controller the ability to receive API commands. API commands are sent via http.
2. To send a command, type the API command into a web browser using values specific to your MediaCento Setup.
All variables in API commands are based on the predefined information from the MediaCento Controller Web Interface. Groups and Presets have to be defined before calling an API command. If a transmitter or receiver are not named, then their IP address (Periods Included) will be used in the API calls.
DEFAULT API CREDENTIALS
• user name: apiuser
• password: apipass2015
SWITCH ONE RX TO TX
http://bbox.local.net/bbapi/v1/apiuser/switchrx?u=apiuser&p=apipass2015&t=tx1&r=rx1
**Replace bbox.local.net with hostname or IP address of MediaCento Controller box
Parameters:
u = API Username
p = API Password
t = Transmitter Name
r = Receiver Name
SWITCH GROUP TO TX
http://bbox.local.net/bbapi/v1/apiuser/switchgroup?u=apiuser&p=apipass2015&t=tx1&g=g1
**Replace bbox.local.net with hostname or IP address of MediaCento Controller box
Parameters:
u = API Username
p = API Password
t = Transmitter Name
g = Group Name
STEP 5 (CONTINUED) - API
ACTIVATE A PRESET
http://bbox.local.net/bbapi/v1/apiuser/switchpreset?u=apiuser&p=apipass2015&preset=p1
**Replace bbox.local.net with hostname or IP address of MediaCento Controller box parameters:
u = API Username
p = API Password
preset = Preset Name
EXAMPLES
hhttp://10.8.10.1/bbapi/v1/apiuser/switchpreset?u=apiuser&p=apipass2015&preset=preset1
http://10.8.10.1/bbapi/v1/apiuser/switchrx?u=apiuser&p=apipass2015&t=169.254.3.68&r=169.254.2.3
NOTES
STEP X - Name of Step
COPYRIGHT 2018 BLACK BOX CORPORATION. ALL RIGHTS RESERVED.
VSW-MC-CTRL_QSG_REV3.PDF