VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash...

75
AN ISO 9001 & 14001 COMPANY TENDER DOCUMENT TENDER No: DLI/CON/748/733 FOR CONSTRUCTION OF MEGA URBAN EDUCATIONAL COMPLEX AT PALLUR HILLS, KANISI, BERHAMPUR, DIST: GANJAM, ODHISA VOLUME – III Price Bid/ BOQ

Transcript of VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash...

Page 1: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

         

AN ISO 9001 & 14001 COMPANY

TENDER DOCUMENT

TENDER No: DLI/CON/748/733

FOR

CONSTRUCTION OF MEGA URBAN EDUCATIONAL COMPLEX AT PALLUR HILLS, KANISI, BERHAMPUR, DIST: GANJAM, ODHISA

VOLUME – III

Price Bid/ BOQ            

 

Page 2: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

ESTIMATED COST (Rs.)

1 2 3 4 5

In figures In words In figures In words

1 CIVIL WORKS 29,70,25,723.85

2 ELECTRICAL WORKS 2,61,65,853.68

3 AIR CONDITIONING SYSTEM 20,49,561.79

4 SANITARY & PLUMBING WORKS 2,93,26,035.59

5 FIRE FIGHTING WORKS 4,77,843.80

35,50,45,018.71

BIDDERS FINANCIAL OFFER:

(In Figures)

(In Words)

Total Tender Cost

Seal & Signature of Bidder

ENGINEERING PROJECTS (INDIA) LTD.(A GOVERNMENT OF INDIA ENTERPRISE)

QUOTING SHEET FOR BIDDERS

NIT No. DLI/CON/748/733

6= (3 x 4 )

Name of work: Construction of Mega Urban Educational Complex at Pallur Hills, Kanisi, Berhampur, Dist: Ganjam, Odhisa

SI. No. DESCRIPTION TO BE QUOTED BY TENDERER

% (-) BELOW/ AT PAR/ (+) ABOVE AMOUNT IN Rs. AFTER ADDING % (-) BELOW / (+) ABOVE/ AT PAR

Page 3: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl. no. Description Estimated Cost(Rs.)

Add Service Tax @ 5.8%(Rs.)

Total Estimated Cost (Rs.)

1 CIVIL WORKS 28,07,42,650.14 1,62,83,073.71 29,70,25,723.85

2 ELECTRICAL WORKS 2,47,31,430.70 14,34,422.98 2,61,65,853.68

3 AIR CONDITIONING SYSTEM 19,37,203.96 1,12,357.83 20,49,561.79

4 SANITARY & PLUMBING WORKS 2,77,18,370.12 16,07,665.47 2,93,26,035.59

5 FIRE FIGHTING WORKS 4,51,648.20 26,195.60 4,77,843.80

Grand Total 35,50,45,018.71

ABSTRACT

Name of work: Construction of Mega Urban Educational Complex at Pallur Hills, Kanisi, Berhampur, Dist: Ganjam, Odhisa

NIT No. DLI/CON/748/733

Page 4: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

EARTH WORKSl no

BOQ Description Qty Unit Rate Amount

1

Earth work in excavation in Hard rock by mechanical means (Hydraullic excavator)/ manual means overareas (exceeding 30 cm in depth, 1.5 m in width as well as 10sqm on plan) inculding disposal of excavated earth up to 50 m and lift upto 1.5m with all lead and lift including shoring, shuttering & dewatering (if required) with cost of all Labour, Labour cess ,Hire & Running charges of the water pumps, T & P required for the work complete as directed by the Engineer- in- charge.

6466.81 cum 119.87 775155.31

2Disposal of surplus excavted materials by mechanical means from the work side etc. complete. upto 5km. Lead

5580.0 cum 162.90 908981.95

3

Supplying & Filling foundation trenches , plinth & ditches with clean course river sand well watered and rammed in layers not exceeding 23 c.m. in depth with all lead and lift including cost, conveyance, loading, unloading, stacking,royalties and all taxes of sand,cost & conveyance of water, cost of all Labour,labour cess,T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge.

36990.7 cum 549.70 20333771.51

4

Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.

9144.66 cum 87.13 796773.87

Tender for Construction of Mega Urban Educational Complex at Pallur Hills, Kanisi, Berhampur, Dist: Ganjam, Odhisa

(SECTION - 1) CIVIL WORKS

1

Page 5: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

5

Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth

2194.25 sqm 275.42 604341.44

6

Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor :

With Chlorpyriphos/Lindane E.C. 20% with 1% concentration

5477.32 sqm 70.70 387246.52

Total Earth Work : 23806270.6

PLAIN & REINFORCED CEMENT CONCRETE

7

Providing and laying Plain cement concrete of proportion (1:4:8) using 4cm size metal etc. in foundation and floors using cement, 40mm. Size crusher broken H.G.Metal and screened and washed sharp river sand for mortar of approved quality and from approved quarry inclduign hoisting, lowering and laying concrete to the required level, ramming,watering and curing etc. complete to required levels, laid in layers not exceeding 15cm thick in each layer including cost, conveyance, loading, unloading, royalities and taxes of all materials, cost of all labour,T&P required for the work including shoring, shuttering and dewatering(if required) including hire and running charges of water pump required for the work etc. complete in all respect as directed by the Engineer-in-charge.

1254.28 cum 3517.70 4412193.17

2

Page 6: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

8

Providing and laying in position ready mixed M-25 grade concrete having compressive strength at 28 days test not less than 250 kg/ sq.cm for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, and hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,Labour cess and T&P required for the work improve workability without impairing strength and durability as per direction of the Engineer - in - charge.

Foundation & Ground floor 4690.92 cum 4896.92 22971088.97

First floor 1389.43 cum 4949.80 6877410.43

Second floor 1371.6403 cum 5010.50 6872603.56

Third floor 191.63 cum 5080.40 973548.52

Terrace floor 27.25 cum 5160.80 140625.37

9

Rigid & smooth centering & shuttering for R.C.C. works including false works with all necessary bracing and tiles and supports with leveling centering covered with plastic sheet with provisions for necessary holes and pockets for electrical conduits, pipes, P.H. pipes, for hooks or boxes, switch and board insert plates, clamps and extension bars etc., including dismantling the same after the required interval from the date of casting including cost of all materials, labour,Labour cess , conveyance, loading and unloading, taxes, royalties, scaffolding, watering, curing, sundries, tools and plants, etc., complete as per the direction of the Engineer-in-charge.

(i) In floor & roof slab,landings,balconies, projections,sunshades and chajjas upto 4.3m. Height.Ground floor 6708.70 sqm 364.60 2445992.28

First floor 5189.0 sqm 437.60 2270701.24

Second floor 5505.8002 sqm 525.10 2891095.69

Third floor 543.82 sqm 630.10 342660.64

3

Page 7: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

Terrace floor 96.66 sqm 756.10 73083.11

(ii) In R.C.C. stairs excluding landing but including railing.

Ground floor 312.78 sqm 440.30 137718.62

First floor 274.07 sqm 528.30 144792.03

Second floor 112.28 sqm 634.00 71188.56

Third floor 20.69 sqm 760.80 15737.91

Terrace floor 17.29 sqm 913.00 15789.79

(iii) R.C.C. foundation & plinth band, footing,base of column mass concrete.

Foundation 16014.728 sqm 99.30 1590262.50

(iv) R.C.C. beam & column girders etc.

Ground floor 7627.9689 sqm 546.20 4166396.61

First floor 5468.5807 sqm 655.50 3584654.65

Second floor 5116.6591 sqm 786.60 4024764.05

Third floor 1055.1667 sqm 943.90 995971.85

Terrace floor 111.02 sqm 1132.70 125755.75

(v) R.C.C. Lintel & Sill

Ground floor 1441.74 sqm 240.30 346450.12

First floor 1162.0 sqm 288.30 335003.16

Second floor 1152.105 sqm 346.00 398628.33

Third floor 165.65 sqm 415.20 68777.88

Terrace floor 22.14 sqm 498.20 11030.15

(vi) R.C.C. walls & fins including attached pillasters

Ground floor 124.58 sqm 479.90 59785.99

First floor 92.27 sqm 575.90 53138.01

Second floor 25.33 sqm 691.10 17502.80

4

Page 8: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

10

Cutting,straightening coiled or bent up HYSD/TMT Reinfocement Bars welding or jointing if necessary ,bending, binding,tying the grills as required for R.C.C. works,providing Fan Hooks where necessary and hoising,lowering and placing the same tin proper position according to the approved eesigns and drawings in all floors including cost, conveyance, loading, unloading and taxes or HYSD/TMT Reinforcement Bars and Binding wieres of 18 to 20 gauge required for the work cost of all labour,T&P and scaffolding complete in all respect as directed by the Engineer-in-charge(Payment will be made according to the actual/proper weight of HYSD/TMT Reinforcement Bars and Binding wires consumed in the particular work only)

Foundation & Ground floor 5976.98 Qntl 5441.00 32520766.15

First floor 1840.0853 Qntl 5455.40 10038401.50

Second floor 1796.6571 Qntl 5470.50 9828612.93

Third floor 282.33 Qntl 5486.40 1548994.67

Terrace floor 38.53 Qntl 5503.00 212008.74

11

2.5cm. Damp proof course with C.C (1:2:4) using 12mm. Size hard broken granite chips including cost of all labour,material T & P taxes etc complete in all respect in floors as per the direction of EIC.Ground floor 581.53 sqm 208.60 121307.99

12

Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 6 mm nominal size), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits.

218.27 sqm 729.95 159324.73

Total Plain & Reinforced cement concrete work 120863768.42

BRICK WORK

5

Page 9: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

13

Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12 c.m x 8 c.m in Foundation & Plinth having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge.

Foundation & Plinth 552.11 cum 3538.3 1953532.23

14

Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12 c.m x 8 c.m in superstructure having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge.

Ground floor 1716.0 cum 3571.6 6128872.78

First floor 990.61 cum 3734.55 3699489.00

Second floor 955.45 cum 3921.88 3747154.38

Third floor 439.15 cum 4137.3 1816894.47

Terrace floor 34.08 cum 4385.1 149435.00

6

Page 10: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

15

Brick Masonary using Fly ash bricks of size 25x12x8cm. Having crushing strength not less than 75kg. Per square cm. in cement mortar of mix(1:4) with cement and screened and washed sharp sand for mortar after immersing the Fly ash bricks for 6(six) hours in water before use in the works in Superstructure and similar such type of works with all necessary projections, splays cutting,circular moulding,corbelling, chamfering,watering and curing etc. including cost,conveyance, loading,unloading, royalities and taxes of all materials,cost of all labour, scaffolding, sundires and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. (Half brick work)

Ground floor 179.79 cum 3779.20 679473.97

First floor 165.29 cum 3942.10 651597.28

Second floor 165.06 cum 4129.40 681596.37

Third floor 3.31 cum 4344.80 14360.87

Total Brick work 19522406.34

PLASTERING & PAINTING

16

Providing 12mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary) including watering and curing,rounding of corners etc. complete with cost,conveyance, loading, unloading, royalities and taxes of all materials,cost of all labour,T&P,sundries and scaffolding required for the work etc. as directed by the Engineer-in-charge.

Ground floor 16813.568 sqm 97.50 1639322.86

First floor 10206.862 sqm 100.90 1029872.37

Second floor 9884.7435 sqm 104.40 1031967.22

Third floor 2483.68 sqm 108.10 268485.97

Terrace floor 223.64 sqm 112.00 25047.12

7

Page 11: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

17

Providing 16mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary)including watering and curing,rounding of corners etc. complete with cost,conveyance,loading, unloading,royalities and taxes of all materials,cost of all labour,T&P,sundries and scaffolding required for the work etc. as directed by the Engineer-in-charge.

Ground floor 13134.6 sqm 137.20 1802063.56

First floor 9675.7485 sqm 140.20 1356539.93

Second floor 9305.2886 sqm 143.30 1333447.85

Third floor 2243.90 sqm 146.50 328731.04

Terrace floor 188.94 sqm 149.70 28284.39

18

Providing 6 mm thick cement plaster in cement mortar of mix (1:4) at all height using screened & washed sharp river sand for mortar with approved quality of cement to the ceiling of the Roof Slab, Staircase, Beams, Columns,Landings, Railings,Chajja ,Fins ,Walls ,Jally and Shelves etc. including roughening, scraping, chiseling, cleaning, closed deep chipping with slurry treatment and finished smooth to all R.C.C. Surface including cost, conveyance, loading, unloading, royalties ,stacking and all taxes , cost of all Labour,Labour cess ,Sundries, T&P, Scaffolding, Watering, Curing etc. complete in all respect as directed by the Engineer- in- charge

Ground floor 6903.0 sqm 106.00 731718.28

First floor 5293.7627 sqm 108.40 573843.88

Second floor 4871.8816 sqm 110.80 539804.48

Third floor 515.03 sqm 113.30 58353.18

Terrace floor 78.98 sqm 115.90 9153.78

8

Page 12: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

19

Priming one coat with water bound wall cement primer of approved make including cost, conveyance ,taxes of all materials , cost of all Labour , Labour cess, scaffoldings, staging, sundries,T&P etc. required for the work complete as directed by the Engineer-in-charge.

Ground floor 7787.30 sqm 42.38 330060.72

First floor 7269.13 sqm 43.25 314362.83

Second floor 6788.75 sqm 44.13 299613.88

Third floor 1906.31 sqm 45.05 85875.50

Terrace floor 491.56 sqm 45.99 22606.53

20

Finishing wall surface of walls with cement based wall putty ( water based) of approved make and finished smooth and even surface to receive painting including cost, conveyance ,taxes of all materials , cost of all Labour , Labour cess,scaffoldings, staging, sundries,T&P etc. required for the work complete as directed by the Engineer-in-charge.

Ground floor 7787.30 sqm 74.27 578369.92

First floor 7269.13 sqm 75.09 545812.45

Second floor 6788.75 sqm 75.93 515443.78

Third floor 1906.31 sqm 76.79 146387.51

Terrace floor 491.56 sqm 77.68 38185.10

21 Cement washing one coatGround floor 29033.113 sqm 11.60 336784.12

First floor 17907.241 sqm 11.70 209514.72

Second floor 17273.163 sqm 11.80 203823.32

Third floor 3336.3059 sqm 12.00 40035.67

9

Page 13: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

22

Painting 2 (Two) or more coats with Weather Coat Paint of premium brand Such as Asian/ Berger/ ICI paints or equivalent of approved quality & colour, using required quantities of paint as specified by the manufacturer to give an even shade over a coat of wall priming(water based) on the finished external plastered surface at all height , watering the surface before applying the Weather Coat Paint and curing for the required period including cost, coveyance, loading , unloading ,stacking and all taxes , cost of all Labour, Labour cess, Sundries ,Scafffolding ,Staging and T&P etc. required for the work complete in all respect as directed by the Engineer-in-charge.

Ground floor 11495.085 sqm 69.83 802694.64

First floor 7582.4673 sqm 74.10 561860.82

Second floor 7290.1557 sqm 78.40 571548.20

Third floor 1623.6805 sqm 82.70 134278.38

23

Wall painting two coats with plastic emulsion paint of approved quality colour at all heights to the interior surface of the wall to make an even finished surface including sand papering, applying putty wherever necessary including cost, conveyance, loading, unloading, stacking, all taxes , cost of all Labour , Labour cess,scaffoldings, staging, sundries,T&P etc. required for the work complete as directed by the Engineer-in-charge.

Ground floor 4608.99 sqm 62.6 288523.02

First floor 4644.74 sqm 63.5 294940.83

Second floor 4194.16 sqm 64.5 270523.49

Third floor 1046.31 sqm 65.5 68532.98

Terrace floor 267.92 sqm 66.5 17816.71

24

Wall painting with two coats Distemper of approved quality etc. complete including cost, conveyance ,taxes of all materials , cost of all Labour , Labour cess,scaffoldings, staging, sundries,T&P etc. required for the work complete as directed by the Engineer-in-charge.

Ground floor 13370.89 sqm 46.80 625757.66

First floor 10324.774 sqm 48.20 497654.09

10

Page 14: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

Second floor 9983.0075 sqm 49.60 495157.17

Third floor 1712.6254 sqm 51.10 87515.16

25

French polishing two coats with any approved polish or with prepared polishing materials like spirit,lac of required quantities to give the best polished surfacek to wood work after cleaning the surface smooth including cost, conveyance,loading, unloading, taxes of all materials, cost of all labour, scafolding, sundires, T&P etc. complete as directed by the Engineer-in-charge.

Ground floor 466.64 sqm 80.30 37471.39

First floor 307.49 sqm 83.30 25613.50

Second floor 297.36 sqm 86.40 25691.90

Third floor 8.64 sqm 89.70 775.01

26

Painting with synthetic enamel paint over a coat of primer of approved colour, shade and brand on New wood work /steel work in two or more coats as required to give an even shade including an under coat of suitable primer of approved brand and manufacturer including cost of all materials with taxes and transportation, loading, unloading, scaffolding, all labour, Labour cess, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge including filling gaps with putties, scrapping, sand papering and cleaning the surface to make free from rusts, dusts and oily substances before applying primer etc. complete.

Ground floor 1209.07 sqm 130.90 158267.01

First floor 625.31 sqm 133.80 83667.05

Second floor 613.21 sqm 136.80 83887.02

Third floor 41.85 sqm 139.90 5854.82

Terrace floor 4.32 sqm 143.10 618.19

27Finishing walls with water proofing cement paint of approved shade on new work Two coat to give an even shade

4197.87 sqm 25.48 106972.53

Total Plastering & Painting work 19669133.55

FLOORING

11

Page 15: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

28

2.5cm. thick artificial stone flooring with punning with cement concrete (1:2:4) laid to proper slope in two layers bottom layer being 3/4” (20mm) thick with 1/4” to 3/4” size down graded hard black broken granite stone chips of top layer being 1/4”(6mm) thick with 1/4”(6mm) down graded hard black broken granite stone chips of approved quality and from approved quarry including watering, curing for 7 days with cost, conveyance, royality of all materials and labour with T&P required for the work with royalities, taxes etc.complete in all floors as per direction of Engineer-in-charge.

Ground floor 1917.7264 sqm 223.30 428228.31

First floor 1875.0666 sqm 229.40 430140.28

Second floor 1960.6236 sqm 235.90 462511.11

Third floor 153.76 sqm 242.70 37316.34

29

12mm thick cement plaster in CM(1:4) with cement punning for skirting & Dados including all cost.complete with cost, conveyance, royality of all materials and labour with T&P required for the work with royalities, taxes etc.complete in all floors as per direction of Engineer-in-charge.

Ground floor 225.12 sqm 122.8 27645.29

First floor 196.20 sqm 124.8 24485.95

Second floor 175.29 sqm 126.9 22244.68

Third floor 11.20 sqm 129.02 1444.87

30

Providing 16mm. thick Kota stone flooring of approved quality and colour using in floors over 25mm. Thick cement mortar of (1:1) including cement grouted and slurry for joints cil mixed with required quantity of pigment of approved make to match the shades of kota stone if required including rubbing mechanically and wax polishing watering, curing, cost,conveyance, loading, unloading royalities,taxes of all materials T&P required for the work etc. complete as per direction of Engineer-in-charge.

Ground floor 3083.9292 sqm 904.80 2790339.14

First floor 1820.8982 sqm 917.60 1670856.19

Second floor 1741.1502 sqm 931.00 1621010.84

12

Page 16: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

Third floor 114.40 sqm 945.10 108115.66

Terrace floor 10.35 sqm 960.00 9936.00

31

Providing 16mm. thick Kota stone flooring of approved quality and colour using in Dado over 25mm. Thick cement mortar of (1:1) including cement grouted and slurry for joints cil mixed with required quantity of pigment of approved make to match the shades of kota stone if required including rubbing mechanically and wax polishing watering, curing, cost,conveyance, loading,unloading royalities,taxes of all materials T&P required for the work etc. complete as per direction of Engineer-in-charge.

Ground floor 395.44 sqm 999.80 395361.71

First floor 288.45 sqm 1018.20 293699.79

Second floor 287.98 sqm 1037.50 298775.10

Third floor 9.10 sqm 1057.70 9620.84

32

Supplying,fitting, fixing vitrified tile in floors of size 600x600mm. of premium approved make with application of polymer modified cement based water resistant adhesive bed of required thickness of 10mm. And filling joints with epoxy graout of approved quality including all cost,materials,T&P etc. complete.

Ground floor 528.73 sqm 1144.4 605081.82

First floor 430.61 sqm 1150.2 495290.84

Second floor 410.71 sqm 1156.2 474866.14

33

Supplying,fitting, fixing vitrified tile in skirting of size 600x600mm. of premium approved make over 12mm C.M.(1:3) including all cost,materials,T&P etc. complete.

Ground floor 84.73 sqm 1015.00 85998.41

First floor 72.74 sqm 1023.60 74456.15

Second floor 68.62 sqm 1032.70 70865.94

13

Page 17: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

34

Providing Granite stone prepolished 18mm thick of area above 0.40 Sqm in flooring of approved quality, colour and size in floors, treads on steps and landings in all floors at all height on 25mm thick bed of cement mortar of mix (1:1) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, Labour cess ,sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge.

Ground floor 211.12 sqm 2192.5 462888.27

Third floor 15.83 sqm 2232.9 35345.91

35

Providing Granite stone prepolished 10mm thick of area above 0.40 Sqm in dado/skirting,riser of steps of approved quality, colour and size in dado/ skirting,riser of steps,wall on 12mm thick bed of cement mortar of mix (1:3) laid in proper plumb and line with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, Labour cess ,sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge.

Ground floor 4.76 sqm 1847.70 8799.67

Third floor 2.40 sqm 1905.60 4573.44

14

Page 18: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

36

Supplying, fitting and fixing of Antiskid Ceramic Floor Tiles in flooring using special plain / printed series Ceramic Floor Tile of premium grade ( having minimum thickness 7 mm to 8 mm & size 300 mm x 300 mm OR 400 mm x400 mm, confirming to I.S 13755 of approved quality and shade in floors, treads on steps and landings on 25 m.m thick bed of cement mortar of mix (1:1) laid in proper slope and gradient with screened & washed sharp river sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments (Tiles are to be immersed in the water for required time before use) of approved make to match the shades of the Ceramic Floor Tiles if required including cost, conveyance, loading, unloading, stacking, royalties , all taxes, cost of all Labour, Labour cess ,Sundries, T&P required for the work , Watering , Curing for required days , cleaning the flooring space manually etc. complete in all respect as directed by the Engineer-in-charge.

Ground floor 741.50 sqm 793.50 588377.08

First floor 713.39 sqm 806.30 575203.13

Second floor 710.09 sqm 819.80 582128.50

Third floor 14.76 sqm 833.90 12308.36

37

Supplying, fitting and fixing of ceramic glazed wall Tiles in skirting dado,risers of step and wall using special plain / printed series Ceramic wall Tile of premium grade ( having minimum thickness 6.5 mm to 6.7 mm & size 200 mm x 200 mm OR 200mm x300 mm, confirming to I.S 13753 of approved quality and shade in dado/ skirting,riser of steps,wall on 12mm thick bed of cement mortar of mix (1:3) laid in proper plumb and line with screened & washed sharp river sand for mortar aand fixing with neat white cement slurry, grouting the joints with neat white cement slurry mixed with required quantities of pigments (Tiles are to be immersed in the water for required time before use) including cost, conveyance, loading, unloading, stacking, royalties , all taxes, cost of all Labour,Labour cess , T&P required for the work , Watering , Curing for required days , cleaning the flooring space manually etc. complete in all respect as directed by the Engineer-in-charge.

Ground floor 2402.76 sqm 875.7 2104094.30

First floor 1905.18 sqm 894.1 1703418.76

Second floor 1891.21 sqm 913.4 1727433.04

Third floor 84.21 sqm 933.7 78626.88

15

Page 19: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

38

Providing, laying, commissioning homogeneous vinyle anti static seam less flooring of 2.00 mm thick having net wet of 3 Kg / sqmt, static electrical charges < 2KV , under floor heating (max 27 degree centigrade , thermal resistance approx. 0.01sqm K/W , Light fastness >= level 6 with good resistance ,all complete as per direction of EIC

Ground floor 264.72 sqm 2638.0 698328.19

39 Providing,fixing & laying Cadappa tile of 10 mm thick of approved make Ground floor 45.33 sqm 803.23 36410.60

First floor 40.05 sqm 816.00 32680.80

Second floor 40.05 sqm 829.50 33221.48

40 Paver block Flooring Ground floor 18.68 sqm 602.20 11249.10

41

Providing,fixing of Industrial tile(chequred tile) of approved size and quality over 25mm. Bed cement CM(1:1) and filling the joints with slurry etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, Labour cess ,sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. complete in all respect.

Ground floor 12.06 sqm 666.60 8039.20

Total flooring work 19141418.10

WOOD & PVC WORK

42

Dressed seasoned sal wood work framed and fixed(wrought and put up) in truses, purlins, frames of doors, windows, ventilator and beams, including cost, conveyance, loading, unloading, stacking, royalties , all taxes, cost of all Labour, Labour cess , T&P required for the work , Watering , Curing for required days , cleaning the flooring space manually etc. complete in all respect as directed by the Engineer-in-charge.

18.71 cum 50562.2 946253.24

16

Page 20: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

43

32 mm Thick BWR flush Door Shutter from approved make , vision panel,teak wood lipping,SS Butt Hings(125x85x5.5)(0.07 kg), SS. T. Bolt(250x10) , SS. Handle (250x175 x 40), Mortice lock seven lever (MR), Door stopper, Door closer and as per drawing including cost of all labour,material T & P taxes etc complete in all respect in all floors all height as per the direction of EIC.

1043.61 sqm 5488.0 5727331.68

44

Providing and fixing of Sliding windows of approved make to be fabricated from roll formed sections made of pre-painted steel (base steel as per IS-513 of 0.6 mm thick “D” quality, galvanized as per IS-277with zinc of 120 Gm/Sq.mtr) with total coated thickness of 0.55 mm. Slide guide section should be made of 0.5 mm stainless steel of 430 grade. with paint specification being with primer of 5-7 microns thick and finished paint with polyster paint (Black /Pearl white/ Chocolate Brown) of 12-16 microns alongwith the alkyd backer at the back of 5-7 microns and the Sections for external frame bottom and top should be of 79 x 45 mm. external frame sides should be of 69 x 24 mm, guide for top and bottom should be of 69 x 26mm (Stainless Steel). Section for shutter should be of 26 x 30 mm, Sash bar should be of 23 x 57mm.Accessories / gaskets are to be used as per the manufacturer’s supply and specification like gasket will be made of EPDM. All corner brackets for internal and external are to be made of glass filled nylon. The sections are to be cut to length, joined and assembled by means of corner bracket and frames are fixed to the concrete/masonry walls by means of self expanding screws and glass to be used of 5 mm reflective with all taxes complete.

340.04 sqm 5058.90 1720241.00

45

Providing and fixing factory made uPVC window frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame with Providing and fixing double glazed hermetically sealed glazing in windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant(Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.Extruded section profile size 48x40 mm

1083.195 sqm 6400.00 6932448.00

17

Page 21: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

46

Providing and fixing of Fixed Ventilators of approved make to be fabricated from roll formed sections made of pre-painted steel (base steel as per IS-513 of 0.6 mm thick “D” quality, galvanized as per IS-277 with zinc of 120 Gm/Sq.mtr) with paint specification being with primer of 5-7 microns and finished paint with polyster paint (Black /Pearl white/ Chocolate Brown) of 12-16 microns alongwith the alkyd backer at the back of 5-7 microns and the sizes of outer frame being of 46x52 mm and with all vertical and horizontal mullions are of 46x70 mm and fixed beadings are of 18x25 mm. Accessories / gaskets are to be used as per the manufacturer’s supply and specification like handle being made of high grade aluminium powder coated and with nylon receiver and gasket will be made of EPDM. All corner brackets are to be made of CRCA with zinc phosphating. The mullion caps and louvered-clips should be of glass filled nylon. The sections are to be cut to length ,mitre joined with corner bracket and frames are fixed to the concrete/masonry walls by means of self expanding screws and glass to be used of 4 mm frosted glass

185.76 sqm 4921.50 914217.84

47Sal wood pannel shutter (32mm style & 18mm pannel)

13.84 sqm 3909.80 54101.86

48

Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat . Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

4100.4 Rmt 482.20 1977212.88

49 Providing and fixing to existing door frames.

18

Page 22: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.

1164.15 sqm 2401.15 2795298.77

Total wood & PVC work 21067105.28

STEEL WORK

50Providing and fixing ISI marked oxidised M.S. fan hook conforming to IS:4992 with necessary screws etc. complete : 125 mm

677.0 Nos 110.47 74789.78

51

Supplying, fitting and fixing of M.S grills, grill gates with top and bottom rails, ( as per I.S. specification and as per approved drawings ) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damaged walls/ structures with cement concrete (1:2:4) with black hard crusher broken granite stone chips of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and curing including cost, conveyance, loading, unloading, stacking, royalties and taxes of all materials, cost of all Labour, Labour cess ,Sundries, T&P required for the work etc.complete as per the direction of Engineer in charge ( W.I. / M.S. windows grills, grill gates, collapsible gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows, staircase and parapet railings square bar along with required nos. of nails and screws and other required materials of approved quality and approved size shall be supplied by the contractor at his own cost.)

47847.66 kg 72.53 3470390.78

52

Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mmx32mmx2mm @ 0.90mtr.C/C and stainless square pipe bracing of size 32mmx32mmx2mm in 3 rows in stair case as per approved design and specification ,buffing, polishing etc with cost,conveyance,taxes of all materials, labour, T & P etc. requird for the complete in all respect.

19

Page 23: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

5273.1583 kg 323.70 1706921.34

53

Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.

Using M.S. angels 40x40x6 mm for diagonal braces

141.93 sqm 3073.85 436271.53

Total steel work 5688373.43

WATER PROOFING

54

2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size HG chips including all cost, conveyance, royalty & taxes etc.comp.to work site for new work as per the specification approved by the department & direction of E.I.C

Ground floor 166.22 sqm 223.96 37227.00

First floor 1310.5 sqm 241.00 315830.50

Second floor 3300.41 sqm 260.70 860416.89

Third floor 1590.87 sqm 283.30 450692.05

Terrace floor 42.00 sqm 309.20 12986.40

55

Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of :Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.

IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).

2420.512 sqm 522.90 1265685.72

Total Water proofing work 2942838.57

20

Page 24: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

MISCELLANEOUS WORK

56

Providing and laying in situ five course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm, 2nd & 4th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd layer of roofing membrane APP modified Polymeric membrane 2.0 mm thick of 3.00 Kg/ sqm weight consisting of five layers prefabricated with centre core as 100 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film.5th,the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat

6410.00 sqm 356.9 2287727.22

57

Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.

6410.00 sqm 74.85 479788.13

58

Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.

6410.00 sqm 1133.85 7267972.83

21

Page 25: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

59

Providing and laying roof insulation with 40 mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulation conforming to IS - 12432 Pt. III (density of foam being 40-45 kg/ cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providing a wearing course of 40 mm thick cement screed 1: 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) in chequered rough finish, in panels of 2.5 m x 2.5 m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, all complete as per direction of Engineer-in-Charge.

6410.0 sqm 1167.2 7481746.16

60

Providing & fixing Expandable Polystyrene (EPS), Self Extinguishing (SE) grade sheets of density 18 kg/m3 to 20Kg/m3 and size 1000X500X50 mm on exterior wall on smooth surface with adhesive and dowel nails fixed on it. Application of 2-3mm of base coat of polymerized cementitious coating over insulation layer reinforced fiber mesh. Application of 2-3 mm of skin coat of polymerized cementitious coating over embedded fiber mesh.

13450.656 sqm 1183.6 15920196.44

61Providing and fixing sheet covering over expansion joints with iron screws as per design.

Aluminium fluted strips 3.15 mm thick.318.56 Rmt 330.05 105140.73

62

Providing and placing the baker rod of the required dimension in the expansion joint so as to maintain the required depth to receive the polysulphide sealant. Application of primer on the concrete surface followed by poly sulphide sealant to seal the gap up to 50 mm width to depth ratio of 2:1. The rate is inclusive of all materials, labour, transportation , taxes etc complete

318.56 Rmt 2300.00 732688.00

63Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete

6176.60 sqm 422.80 2611464.87

Total Miscellaneous work 36886724.38

SITE DEVELOPMENT

22

Page 26: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

64

Supplying and filling good quality moorum along road alignment including watering, and consolidating with Vibratory Roller etc complete.

886.81 cum 676.27 599719.10

65

Providing, laying, spreading, and compacting stone agreegate of specific size to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 8 10 tones PRR to proper grade and camber, applying and brooming requisite type of screening / binding materials to fill up\the interstices of course agreegate, watering and compacting to the required density as per Clause 404 of MoSRT&H Specification for road and Bridge work

886.81 cum 2391.81 2121067.11

66

Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).

909.00 cum 24.62 22379.58

67

Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge measured in stacks will be reduced by 8% for payment).

227.25 cum 239.20 54358.20

68

Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) :

Screened through sieve of I.S. designation 20 mm 227.25 cum 167.60 38087.10

69Rough dressing the trenched ground including breaking clods.

3030.00 sqm 0.46 1407.74

70Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.

3030.00 sqm 1.53 4645.60

23

Page 27: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

71

Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Officer-in-charge (Cost of sludge, dump manure and / or good earth to be paid separately).

909.00 cum 16.26 14780.34

72

Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately).

3030.00 sqm 5.58 16892.86

73

Earth work in stoney earth and gravels mixed with stone and boulder not exceeding 0.014 cum in volume within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3m in depth and as per specification approved by the dept.

22314.60 cum 186.94 4171412.35

74

Cutting in disintegrated rock not requiring blasting to be removed by pick axes and crow bars and depositing materials within 50m initial lead and 1.5m initial lift including rough dressing as per direction and specification of the department including stacking the useful materials separately as ordered.

6375.60 cum 303.85 1937215.91

75

Blasting hard and compacted sheet rock excluding sand stone measured in solid including jumping holes cost of explosive fuse, detonator, etc. and stacking the blasted debris clear of work within 50m lead.

3187.80 cum 681.55 2172645.60

Total Site development work 11154611.46

Total Civil & site development amount 28,07,42,650.14

INTERNAL ELECTRICAL WORKS

A Sub-Head I (modular Wiring Items)

24

Page 28: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

1

Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, socket, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.

a) Single light point controlled by one 6A switch or first light point or group control.modular 587 Nos 839.00 492493.00

b) Single light point controlled by one 6A switch for fan/Ex. fan point

488 Nos 1184.00 577792.00

c) subsequent point of group control 344 Nos 633.00 217752.00 c) call bell point 21 Nos 839.00 17619.00 d) 6A Plug on the same board 144 Nos 569.00 81936.00 e) 6A Plug on the separate board 211 Nos 1190.00 251090.00 f) 2x6A Plug on the separate board For computer

point & other use211 Nos 1570.00 331270.00

2

Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with flush switch, socket, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.

a) Single light point controlled by one 6A switch or first light point or group control.modular

1131 Nos 695.00 786045.00

b) Single light point controlled by one 6A switch for fan/Ex. Fan/wall fan point

1078 Nos 1041.00 1122198.00

c) call bell point 61 Nos 695.00 42395.00 d) 6A Plug on the same board 331 Nos 340.00 112540.00 e) 6A Plug on the separate board 467 Nos 866.00 404422.00 f) 2x6A Plug on the separate board For computer

point & other use78 Nos 932.00 72696.00

g) 1x15A Plug on the separate board For power point & other use by 2x2.5 sq. mm wire

74 Nos 1211.00 89614.00

3

Wiring for circuit/submain wiring with the following mentioned size PVC insulated, copper conductor, single core cable ISI marked as approved, in surface/recessed PVC conduit medium ISI marked as approved as required.

a) 2 nos single core 2.5 sq. mm copper wire for phaseand neutral and 01 no of single core 1.5 sq. mmcopper wire for earth continuty conductor.(LDB toLSB/LIGHT CKT)

1411 Mtr 178.00 251158.00

b) 4 nos single core 2.5 sq. mm copper wire for phase andneutral and 02 nos of single core 1.5 sq. mmcopper wire for earth continuty conductor.(LDB toLSB/5A SOCKET)

625 Mtr 281.00 175625.00

c) 2 nos single core 4 sq. mm copper wire for phase andneutral and 01 no of single core 2.5 sq. mm copperwire for earth continuty conductor.(PDB toPSB/COMP. POINT/AC POINT)

776 Mtr 216.00 167616.00

25

Page 29: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

d) 4 nos single core 4 sq. mm copper wire for phase andneutral and 02 nos of single core 2.5 sq. mmcopper wire for earth continuty conductor.(PDB toPSB/COMP. POINT/AC POINT)

553 Mtr 326.00 180278.00

e) 2 nos single core 6 sq. mm copper wire for phase andneutral and 01 no of single core 4 sq. mm copperwire for earth continuty conductor.(LFDB TO LBDB)

205 Mtr 266.00 54530.00

f) 4 nos single core 6 sq. mm copper wire for phase andneutral and 02 nos of single core 4 sq. mm copperwire for earth continuty conductor.(LFDB TOLBDB/power unit/point)

233 Mtr 542.00 126286.00

g) 4 nos single core 10 sq. mm copper wire for phase andneutral and 02 nos of single core 6 sq. mm copperwire for earth continuty conductor.(LFDB TOLBDB/PBDB/ LAB. Power point)

288 Mtr 716.00 206208.00

h) 4 nos single core 16 sq. mm copper wire for phase and neutral and 02 nos of single core 10 sq. mm copper wire for earth continuty conductor.(PFDB TO PBDB/AC/UPS IN.OUT/ LAB. Power point)

246 Mtr 1242.00 305532.00

4

Supplying and fixing 5/6A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

54 Nos 103.00 5562.00

5

Supplying and fixing 3 pin 5/6A modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

54 Nos 135.00 7290.00

6

Supplying and fixing 15/16A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

77 Nos 140.00 10780.00

7

Supplying and fixing 15/16A modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

77 Nos 183.00 14091.00

8

Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole and earth metal enclosed plug top alongwith 32 amps. C-series, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required.

68 Nos 1378.00 93704.00

26

Page 30: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

9Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.

a) 4 moudle(125mmx75m) 61 Nos 229.00 13969.00 b) 1 moudle(75mmx75m) 79 Nos 198.00 15642.00 c) 12 moudle(200mmx150m) 56 Nos 510.00 28560.00

10

Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

a) 40 MM 471 mtrs 76.00 35796.00 b) 50 MM 250 mtrs 87.00 21750.00

11 Supply and fixing modular type indicator on the existing switch box/cover

242 Nos 99.00 23958.00

12

Supplying and installation of AC starter Modular type,L&T make or any other equivalent reputed make as approved coil voltage-415 Volt A.C. & O/L range of 9-14A range on mod Box of suitable size including moudlar cover.

44 Nos 546.00 24024.00 Total 6362221.00

B Sub-Head II (Light fitting Fixture & Fan)

13

Supplying, installation, of exhaust fan of heavy duty 380 mm sweep with louvers of exhaust fan in the existing wall, including fixing & conntection.

341 Nos 4177.00 1424357.00

14

Supplying, installation, of exhaust fan of heavy duty 300 mm sweep with louvers of exhaust fan in the existing wall, including fixing & conntection.

170 Nos 3036.00 516120.00

15

Supplying, installation, testing and commssioning of 1400 mm sweep white/milky colour ceiling fan including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required.

445 Nos 2158.00 960310.00

16

Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour ceiling fan including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required.

27

Page 31: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

190 Nos 1771.00 336490.00

17

Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour ceiling fan including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required.

99 Nos 1761.00 174339.00

18

Supplying, installation, testing and commssioning of 900 mm sweep white/milky colour ceiling fan including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required.

88 Nos 1564.00 137632.00

19Supplying & installation of modular rotary step electronics type fan regulator

822 Nos 568.00 466896.00

20

Supplying and fixing of LED fitting with glass cover, in existing false ceiling/Surface wire guard etc. of 16W LED Lamp of approved quality including supply and fixing of FTL with connection etc. as required.

12 Nos 3961.00 47532.00

21

Supplying and fixing of Surface type LED fitting with glass cover, wire guard etc. of 15W of approved quality including supply and fixing of LED with connection etc. as required.

233 Nos 2551.00 594383.00

22

Supplying and fixing of CONCEALED type LED fitting with glass cover, wire guard etc. of 15W approved quality including supply and fixing of LED with connection etc. as required.

44 Nos 2510.00 110440.00

23

Supplying & installation, testing and commissioning of prewired, LED TUBE fittings with one No 1x22 watt,6K LED tube, reputed make ISI marked as approved with all accessories and tubes etc. directly on ceiling/wall on two wooden round block, including connections with 1.5 sq mm PVC insulated, copper conductor, single core cable etc.as required.

1107 Nos 2654.00 2937978.00

28

Page 32: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

24

Supplying & installation, testing and commissioning of 144 watt LED flood light luminaries with 144watt LED lamp, of reputed make ISI marked as approved with all accessories incluiding connection with 2.5sq mm cable etc. as required.

4 Nos 31651.00 126604.00

25

Supplying & installation, testing and commissioning of 26 watt GATE LIGHT luminaries with 26 watt lamp, of reputed make ISI marked as approved with all accessories and p/f 1 no 26 watt CFL lamp (1 x 26W) incluiding connection with 2.5sq mm cable etc. as required.

4 Nos 3804.00 15216.00

26

Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required.(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

759 Nos 45.00 34155.00

27

Supplying, installation, testing and commssioning of high speed wall fan of reputed make star rated as approved including wiring with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required.

290 Nos 2338.00 678020.00

28Supplying and fixing of CFL LAMP of reputed make ISI marked as approved in existing angle holder including connection etc. as required.

142 Nos 238.00 33796.00

29

Supplying and fixing of BULK HEAD FITTING with CFL LAMP of reputed make ISI marked as approved in existing angle holder including connection etc. as required.

41 Nos 956.00 39196.00

Total 8633464.00

TELEPHONE & LAN WIRRING

TELEPHONE

30

Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required

29

Page 33: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

348 Mtr 33.00 11484.00

31Supply & drawing of the 4 pair,0.5 sqmm telephone cables in existing surface/ recessed conduit etc. as required.

624 Mtr 18.00 11232.00

32

Supplying and telephone socket socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required

193 Nos 140.00 27020.00

33

Supply, Delivery, Installation & Testing of Information Outlet with SMB I/O boards containing a clip-in-type modular Data socket with top fixed on metallic concealed box including connections and making good the damages caused complete as per direction of Engr.-in-charge.

126 Nos 152.00 19152.00

34Supplying and Commissioning of suitable Line Digital EPABX with maintenance free Battery Back up.4 TNX ANALOG

1 Nos 99000.00 99000.00

35Supplying and Commissioning of suitable Line Digital EPABX with maintenance free Battery Back up.3 TXN,ANALOG TYPE

2 No 51000.00 102000.00

36 Supplying & Commissioning of Telephone Hand Set.

100 Nos 500.00 50000.00

37

Supplying & installation of 100 pair , moudles with locking & key arrangements fabricated with MS sheet & powder coated to be fixed on concealed manner incl. good the damages. (For common purpose)

13 Nos 1500.00 19500.00

38

Supplying & installation of 100 pair , moudles with locking & key arrangements fabricated with MS sheet & powder coated to be fixed on concealed manner incl. good the damages.

10 No 2000.00 20000.00

39

Supplying & installation of 10pair , moudles with locking & key arrangements fabricated with MS sheet & powder coated to be fixed on concealed manner incl. good the damages.

1 No 500.00 500.00

30

Page 34: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

LAN

40 Supplying and Commissioning of 6 U Rack with all accessories.

10 Set 6000.00 60,000.00

41 Supplying & Commissioning of Managed Cat 6 24 Port Switch.

3 Set 38000.00 1,14,000.00

42Supplying & Commissioning of Managed Cat 6 24 Port Switch.

2 Set 21000.00 42,000.00

43Supplying & Commissioning Cat 6 24 Port Patch Panel.

6 Set 8000.00 48,000.00

44

a) Patch Chord CAT 6 One meter long. 157 Set 180.00 28,260.00

b) Patch Chord CAT 6 Two meter long. 157 Set 200.00 31,400.00 Total 683548.00

BDBS,DB,AC DB,FLOOR PANELS,MCBS

45

Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts, on surface/recess, complete with terminal blocks, duly prewired with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar OF reputed make ISI marked as approved

a) 4 (8+12)way, Double Door TPN DB(comp., light, power, UPS) 26 Nos 3618.00 94068.00

b) 12 way SPN DB (Double door) (comp., light,power,UPS)

39 Nos 2236.00 87204.00

c) 8 way SPN DB (double door)(for each room) 12 Nos 1235.00 14820.00 d) 6 way SPN DB (SINGLE door)(for each room) 24 Nos 712.00 17088.00

46

Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of approved make ISI marked in the existing MCB DB complete with connections.

974 Nos 295.00 287330.00

47

Supplying and fixing 63 Amps rating, TPN, 415 volts, RCCB,300mA of approved make & ISI marked in the existing MCB DB complete with connections, testing and commissioning etc. as required.

32 Nos 4502.00 144064.00

Supplying and fixing:

31

Page 35: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

48

Supplying and fixing 40Amps DP 240 volts, RCCB,300mA of approved make & ISI marked as approved in the existing MCB DB complete with connections.

69 Nos 3428.00 236532.00

FDB POWER/AC DB

49

S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR EACH FLOOR POWER,AC load power,GF,1F,2F)

In commer- 01 number of 125Amps TP MCCB. (Of reputed make ISI marked)

Busbar- 04 numbers of 150Amps Electrolytic copper busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. Out going- (i) 02 numbers 63Amps TPN MCB Of reputed make ISI marked)(FOR UPS,POWER DB ,EACH FLOOR)(ii) 02 numbers 32Amps TPN MCB (Of reputed make ISI marked)( For both light and power supply DB).

(iii) 02 numbers 40Amps DP MCB (Of reputed make ISI marked) (For both light and power supply, SPARE).Instrument- (i) 03 numbers phase indicating lampwith toggle switch & HRC fuse.(ii) 01 set of 0-100Amps Ameter with selecter switch &CTS.(iii) 01 set of 0-500 voltmeter with selecter switch. 5 Set 59896.00 299480.00

FDB UPS/LIGHT

50

S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR FLOOR/UPS,light load in Ground floor,1st floor,2nd floor,3rd floor)

In commer- 01 number of 63Amps TPN MCB. (Of reputed make ISI marked)Busbar- 04 numbers of 100Amps Electrolytic copperbusbar duly sleeved by color coaded PVC sleeve &supported by suitable size DMC insulator.

Out going-02 numbers 32Amps TPN MCB (Ofreputed make ISI marked) ( For both light and powersupply DB).02 numbers 40Amps DP MCB (Of reputed make ISImarked) (For both light and power supply,SPARE).

32

Page 36: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

Instrument- (i) 03 numbers phase indicating lampwith toggle switch & HRC fuse.(ii) 01 set of 0-60Amps Ameter with selecter switch &CTS.(iii) 01 set of 0-500 voltmeter with selecter switch.NB- This panel should have proper earth bysuitable rated copper flat. 6 Set 42326.00 253956.00

UPS SYSTEM

51Supplying & fixing of ON-Line UPS 10 KVA 2 hour Backup time with Battery and Battery Rack.

4 Set 287500.00 1150000.00

52

S/I/T&Commissioning of LT indoor WALL mounted cubical type UPS in commer ENCLOSURE made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR UPS) with 125A TPN MCCB 01 NO.

4 Set 6500.00 26000.00 Total 2610542.00

EARTHING

53

Earthing with Copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonary enclousure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt complete as required.

2 Nos 10889.00 21778.00

54

Supply of materials and installation of pipe earth electrode made out of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ termination of G.I. flat / wire with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.

17 Nos 4000.00 68000.00

55Excavation of all kinds of soil up to 3 meters depth incluiding refilling (Except rocky soil )

21 Cum 213.00 4473.00

56Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required.

286 Mtr 100.00 28600.00

33

Page 37: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

57Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections etc. as required.

43 Mtr 917.00 39431.00

58Refilling/Back filling soft soil with borrowed within a lead of 5 K.M. etc. as required.

11 Cum 650.00 7150.00

59

Excavation of hard-rock up to 3 meters depth including getting out the excavated soil disposal of the excavated soil as directed with lead of 50 meters.

11.5 Cum 1100.00 12650.00

60Supplying and making brick massonary pedastal with extra super structure including cement plastering etc as required.

5.15 Mtr 2600.00 13390.00 Total 195472.00

LIGHTENING CONDUCTOR

61

Providing and fixing of lightning conductor finial, made of 25 mm dia 300mm long, copper tube, having single prong at top, with 85 mm dia 3mm thick copper base plate including holes etc. complete as required

112 Nos 1918.00 214816.00

62Fixing of lightning conductor finial with base plate including holes etc. complete as required.

112 Nos 142.00 15904.00

63

Jointing copper (with another copper base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required

112 Nos 68.00 7616.00

64

Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)

928 mtrs 356.00 330368.00

65

Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)

758 mtrs 367.00 278186.00

34

Page 38: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

66

Providing and fixing testing joint, made of 20 mm X 3 mm thick copper strip, 125 mm long, with 4 nos. of tinned brass bolts, nuts, chuck nuts and spring washers etc. complete as required.

128 Nos 218.00 27904.00

67Providing and laying copper tape 32 mm X 6 mm from earth electrode directly in ground as required.

404 mtrs 1206.00 487224.00 Total 1362018.00

CABLING AND END TERMINATION

68

Supplying and laying of one number PVC insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade of approved make of following size cables with in different types laying.

a) 3.5 core x 300 sq mm (surface)(s/s to MDB double RUN,SINGLE RUN FOR DG SET,APFC PANEL)

22.0 Mtr 2082.00 45804.00 b) 3.5core x 35 sq mm (surface)(POWER PANEL TO

UPS I/C,light PANEL) 20.0 Mtr 338.00 6760.00 c) 3.5core x 35 sq mm (surface)(MDB TO LIGHT

PANEL) 56.0 Mtr 338.00 18928.00 d) 3.5core x 70 sq mm (surface)(Light POWER supply to

FLOOR PANEL NOT LOADED HEAVILY)50.0 Mtr 625.00 31250.00

e) 2 core x 4 sq mm (surface)(for BUILDING FOCUS LIGHT) 45.0 Mtr 200.00 9000.00

f) 3.5 core x 240 sq mm (surface)(s/s to MDB singleRUN,SINGLE RUN FOR DG SET,APFC PANEL)

16.0 Mtr 1718.00 27488.00 f-1) 3.5 core x 240 sq mm (under ground including

excavation & refilling) 138.0 Mtr 1826.00 251988.00 a-1) 3.5 core x 300 sq mm (under ground including

excavation & refilling) 67.0 Mtr 2190.00 146730.00 b-1) 3.5core x 35 sq mm (under ground including

excavation & refilling) 104.0 Mtr 486.00 50544.00 a-3) 3.5 core x 300sq mm (in pipe, including supply of

pipe) 8.0 Mtr 2028.00 16224.00 b-3) 3.5core x 35 sq mm (in pipe,including supply of pipe)

27.0 Mtr 331.00 8937.00 a-4) 3.5 core x 300 sq mm (open duct) 22.0 Mtr 2019.00 44418.00 d-4) 3.5core x 70 sq mm (OPEN DUCT)(To FLOOR

PANEL) 104.0 Mtr 576.00 59904.00 b-4) 3.5core x 35 sq mm (open duct) 103.0 Mtr 328.00 33784.00 f-2) 3.5 core x 240sq mm (in pipe, including supply of

pipe) 16.0 Mtr 1664.00 26624.00 f-3) 3.5 core x 240 sq mm (open duct) 28.0 Mtr 1656.00 46368.00

3.5core x 70sq mm (under ground includingexcavation & refilling) 99.0 Mtr 746.00 73854.00

3.5core x 70 sq mm (in pipe,including supply ofpipe) 28.0 Mtr 581.00 16268.00

3.5core x 35 sq mm (surface)(MAIN INCOMMER) 4.0 Mtr 338.00 1352.00

35

Page 39: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

69Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.

a) 3.5 core x300 sq mm 4.0 Nos 950.00 3800.00 b) 3.5 core x35sq mm 20.0 Nos 245.00 4900.00 c) 3.5 core x70 sq mm 10.0 Nos 324.00 3240.00 d) 3.5 core x240 sq mm 8.0 Nos 850.00 6800.00 e) 3.5 core x70 sq mm 6.0 Nos 500.00 3000.00

70

Providing,fixing and laying of fallowing dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling.

50 mm dia 45.0 mtrs 453.00 20385.00 80 mm dia 16.0 mtrs 604.00 9664.00

Total 968014.00

PANELS

MDB

71

S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing.

In commer- 01 number of 630 Amps TPN MCCB(of approved make & ISI marked)Busbar- 04 numbers of 700Amps Electrolytic copperbusbar duly sleeved by color coaded PVC sleeve &supported by suitable size DMC insulator. Out going- (i) 01 number of 250A C/O. (of approvedmake & ISI marked)

(ii) 3 No. 125 amp TP MCCB(of approved make & ISImarked)(FOR POWER FLOOR PANEL/AC PANEL)

(iii) 6 numbers 63Amps TPN MCB (of approved make& ISI marked)(FOR UPS,LIGHT PANEL ,EACHFLOOR)(iv) 06 numbers 32Amps TPN MCB (of approvedmake & ISI marked)( For both light and power supplyDB).

Instrument- (i) 06 numbers phase indicating lampwith toggle switch & HRC fuse.(ii) 01 set of 0-600Amps Ameter with selecter switch &CTS.(iii) 02 set of 0-500 voltmeter with selecter switch. 1.0 Set 211777.00 211777.00 NB- This panel should have proper earth bysuitable rated copper flat.

36

Page 40: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

72

S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing.

In commer- 01 number of 250 Amps TPN MCCB(of approved make & ISI marked)Busbar- 04 numbers of 300Amps Electrolytic copperbusbar duly sleeved by color coaded PVC sleeve &supported by suitable size DMC insulator.

Out going- (i) 01 number of 125A C/O. (of approvedmake & ISI marked)(ii) 1 No. 125 amp TP MCCB with 100A 3P KWHMETER(of approved make & ISI marked)

(iii) 4 numbers 63Amps TPN MCB with 10-60A KWHMETER ((make- L&T/LEGRAND or equivalentreputed make ISI marked)(FOR MESS/HOSTELPANEL)(iv) 02 numbers 32Amps TPN MCB (of approvedmake & ISI marked) ( For SPARE).Instrument- (i) 06 numbers phase indicating lampwith toggle switch & HRC fuse.(ii) 01 set of 0-200Amps Ameter with selecter switch &CTS.(iii) 02 set of 0-500 voltmeter with selecter switch. 2.0 Set 162372.00 324744.00 NB- This panel should have proper earth bysuitable rated copper flat.

73 METER PANELS/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuittotal) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing.

In commer- 1 numbers 125A TP MCCB (ofapproved make & ISI marked)01 no BUSBAR chamber with 150A E.C BAR dulysleeved by colour coaded sleeve ,supported by DMCbus bar insulator.Outgoing-13 numbers 63Amps DP MCB with 10-60AKWH METER,SINGLE PHASE TYPE (of approvedmake & ISI marked)

Instrument- (i) 06 numbers phase indicating lampwith toggle switch & HRC fuse.(ii) 01 set of 0-100Amps Ameter with selecter switch &CTS.(iii) 01 set of 0-500 voltmeter with selecter switch. 2.0 Set 96561.00 193122.00 NB- This panel should have proper earth bysuitable rated copper flat.

74 METER PANEL

37

Page 41: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuittotal) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing.

In commer- 1 numbers 32Amps TPN MCB with 10-60A KWH METER (of approved make & ISI marked)

02 nos of 32A DP MCB for AC.,inverter.Instrument- (i) 03 numbers phase indicating lampwith toggle switch & HRC fuse. 1.0 Set 15637.00 15637.00 NB- This panel should have proper earth bysuitable rated copper flat.

38

Page 42: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

75

S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuittotal) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing.In commer- 1 numbers 63A TPN MCB (of approvedmake & ISI marked)01 no BUSBAR chamber with 150A E.C BAR dulysleeved by colour coaded sleeve ,supported by DMCbus bar insulator.Outgoing-13 numbers 40Amps DP MCB with 10-40AKWH METER,SINGLE PHASE TYPE (of approvedmake & ISI marked)Instrument- (i) 03 numbers phase indicating lampwith toggle switch & HRC fuse.(ii) 01 set of 0-100Amps Ameter with selecter switch &CTS.(iii) 01 set of 0-500 voltmeter with selecter switch. 1.0 Set 85751.00 85751.00 NB- This panel should have proper earth bysuitable rated copper flat.

METER PANEL

76

S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuittotal) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing.

In commer- 1 numbers 32Amps TPN MCB with 10-60A KWH METER (of approved make & ISImarked)WITH 40A E.C BUSBAR.Instrument- (i) 03 numbers phase indicating lampwith toggle switch & HRC fuse.NB- This panel should have proper earth bysuitable rated copper flat. 2.0 Set 14101.00 28202.00

Total 859233.00

77 Supply of A,C with indoor and outdoor unit1.5 TR high wall split A.C 5.0 Each 41542.00 207710.002 TR high wall split A.C 25.0 Each 51484.00 1287100.00

78

Supply,installation of hard/soft copper refregrant piping,complete with fitting of bends and other nesessary material to complete the job.

1.5 TR to3 TR high wall split A.C 243.0 mtr 702.00 170586.00

79Supply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job.

1.5 TR to 3 TR high wall split A.C 167.0 no 1043.00 174181.00

SPLIT TYPE AIR CONDITIONER WITH ALL ACCESSORIES

39

Page 43: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

80

Supply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job.

25mm nom. Dia pipe,B1 88.0 mtr 141.42 12444.96

81 SHEET METAL WORKSCONTROL CABLESupply,laying of control cable and other nesessary material to complete the job.For 1.5 TR to 2 TR high wall split A.C 78.0 mtr 112.00 8736.00

82TESTING AND COMMISSIONING OF AIR CONDITION1.5 TR high wall split A.C 6.0 Each 2466.00 14796.002 TR high wall split A.C 25.0 Each 2466.00 61650.00

Total 1937203.96Total Internal Electrification work 21674512.00

EXTERNAL ELECTRIFICATION

500 Kva TRANSFORMER

83Supplying & installation of 100x116 mm RS Joist, 9 mtr long x 2 nosx23 Kg=414 Kg

445.0 kg 81.00 36,045.00

84Supplying & installation of Pressure Channel 100 x 50 x 6mm MS channel each 2.8 mtr. Long( 9.2 K.g. per mtr.)x2 Nos

75.0 kg 89.00 6,675.00

85Supplying & installation of S/S DP bressing chhanel 75 x 40 x 6mm MS channel each 2.8 mtr. Long( 6.8 K.g. per mtr.)x2 Nos

55.0 kg 89.00 4,895.00

86Supplying & installation of AB Swith & HG Fuse, Mounting Channel 75x40x6 -2.8 mtr.long, 4 nos.(6.8K.g. per mtr.)

82.3 kg 89.00 7,324.70

87Supplying & installation of Cantilever chhanel for supporting AB Switch arm, 75x40x6-1 mtr. Long, 2 nos.(6.8 K.g. per mtr.)

27.0 kg 89.00 2,403.00

88Cantilever chhanel for supporting HG Fuse 50 x 50 x 6 mm MS Angel (1.0 mtrs. Long 2 nos.)4.5K.g. per mtr.

17.0 kg 89.00 1,513.00

40

Page 44: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

89

Supplying & installation of Angle for Cantilever arrrangement for AB Switch & HG Fuse 50 x 50 x 6 -2 mtr .each 2 nos.(4.5 K.g. per mtr.)

26.0 kg 89.00 2,314.00

90Supplying & installation of S/S DP bressing Angle 50 x 50 x 6 mm - 2.8 mtr. Long 2 nos.(4.5 K.g. per mtr.) with side angel ( Total 9 mtr.)

51.0 kg 89.00 4,539.00

91Supplying & installation of Angle for mounting LT distribution Box 50 x 50 x 6 mm MS Angel -2.5 mtrs.each Long 2 nos.( 4.5 K.g. per mtr.)

26.0 kg 89.00 2,314.00

92 Supplying & installation of 11KV AB Switch 3 Pole (200 Amp.)

1.0 set 13304.00 13,304.00

93Supplying & installation of 11KV HG Fuse 3 Pole (400 Amp.)

1.0 No 10348.00 10,348.00

94Supplying & installation of11 KV L.A. 12KV-10KA

3.0 No 2217.00 6,651.00

95Supplying & installation of+B7 H.T.stay set ( Complete )

2.0 set 1035.00 2,070.00

96 Supplying & installation of H.T. Stay Insulator2.0 No 59.00 118.00

97Supplying & installation of H.T. Stay clamp (1.95 K.g./ Pair )

2.0 Pair 216.00 432.00

98 Supplying & installation of 7/10 SWG Stay Wire

21.0 kg 111.00 2,331.00

99

Supplying & installation of of materials and installation of pipe earth electrode made out of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ termination of G.I. flat / wire with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.

5.0 No 2217.00 11,085.00

41

Page 45: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

100 Supplying & installation of No.6 GI Wire20.0 kg 89.00 1,780.00

10120 K.g. 89.00 1,780.00

102

Fixing of stay set with 0.5Cum cement concret foundation 1:3:6 size ( 900mmx 600mm x900mm) using 40mm BHG metal with all labour and material except stay set , stay wire , stay insulator .

2.0 No 2593.00 5,186.00

103

Supplying & installation of Concreting of support C.C - 1:4:8 using 40mm BHG metal size - 5'x2'x2' = 20CFT = 0.570CumPadding 900x600x150mm = 0.081 0.651Cum @ 3071.25= 1999.38 each

2.0 No 2956.00 5,912.00

104

Couping of support section 15''x15'' ( 3.9Cft) height 2'-6' ( 1' - 6'' above G.L & 1' - 0' below G.L ) in C.C 1:2:4 using 12mm BHG metal & curing for 5 days

2.0 No 757.00 1,514.00

105

Supplying & installation of Materials for Machinery work for Earth Pit,Charcoal, Salt etc including construction of earthing chamber (Size: 2"x2") and RCC slab cover

5.0 No 2542.00 12,710.00

106 Supplying and Laying of HT cable on existing pole

3cx120 sq. mm XLPE cable.,11kv , Double run for 500KVA Transformer. 35.0 Mtrs. 2452.00 85,820.00

107

Supplying and making out door end termination with cast resin compound aluminium lugs and other jointing materials for 3cx120 sq.mm size of PVC insulated armoured and PVC sheathed aluminium conductor cable of 1.1 KV grade as required.

2.0 set 25475.00 50,950.00

108Supplying & installation of 50x6mm copper Z clamp for TFR LT 4nos x0.8kg each for connection of LT cable

9.0 kg 1242.00 11,178.00

109 Supplying & installation of Red Oxide paint3.0 ltr 126.00 378.00

110 All. Paint for painting of pole & transformer.4.0 ltr 140.00 560.00

Supplying & installation of 40x6mm GI Flat for nutral

42

Page 46: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

111 Black Paint for painting of angle & channel.1.0 ltr 126.00 126.00

112Supplying & installation ,fixing of Ms Nut , Bolt & Washer

36.0 kg 111.00 3,996.00

113

Supply & Installation of Out Door type Transformer ONAN type with Copper winding having 500KVA rating, 11 KV / 415 Volts 3 Phase 50 Hz Vector Group DY-11, Transformer shall operate without injurious heating at the rated KVA at any voltage within +/- 10% of the rated voltage of that particular tap.Transformer shall be provided with ON Load Tap Changer arrangement in steps of 1.25% with range from + 5% to – 15%. Oil Conservator, Silica jail breather having connecting terminals on HV side suitable for bare condcutor conenction, Cable End Box on medium voltage side suitable for 1.1 KV 3.5 Core UG Cable, on Double Pole Strucutre or Brick / CC / RCC Platforms with all fittings, accessories, fill with flitered Transformer Oil including testing & commissioning etc. complete as required.

500 KVA 1.0 No 555754.00 5,55,754.00

114Supplying & installation of 100x116mm RS Joist 4mtr longx23kg for resting of LT cable

92.0 kg 81.00 7,452.00

115Construction of Plinth for TFR 6ft hight (below GL2ft)x5ftx5ft

1.0 No 17739.00 17,739.00

116

Barbed Fencing (size 15'x15' )with constn. of retaining wall ,erection of RCC fencing post, Sand filling and metal spreading, Fixing of Iron gril gate etc as per CESU specification

1.0 No 54326.00 54,326.00

117Providing and fixing 25mm x 5 mm G.I strip on surface or in recess for connections etc. as required.

15.0 Mtr 130.00 1,950.00

118Sundries for survey , PVC tape, Ampire tape,Danger Board, small size nut & Bolt preparation of drawing cable socket etc

1.0 LS 6209.00 6,209.00

Total 939681.70

CABLING AND END TERMINATION FROM SUBSTATION TO OFP

43

Page 47: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

119

Supplying and laying of one number PVC insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade of approved make of following size cables with in different types laying.

a) 3.5 core x 400 sq mm (surface)(s/s to OFP double RUNFOR transformer) 5.0 Mtr 2618.00 13090.00

b) 2 core x 4 sq mm (surface)(for S.S FOCUS LIGHT)21.0 Mtr 200.00 4200.00

a-1) 3.5 core x 400 sq mm (under ground includingexcavation & refilling) 28.0 Mtr 2726.00 76328.00

a-3) 3.5 core x 400sq mm (in pipe, including supply of pipe)

4.0 Mtr 2564.00 10256.00

a-4) 3.5 core x 400 sq mm (open duct) 8.0 Mtr 2556.00 20448.00

120Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.3.5 core x400 sq mm 4.0 Nos 1200.00 4800.00

121

Providing,fixing and laying of fallowing dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling.

50 mm dia 5.0 mtrs 453.00 2265.00 80 mm dia 5.0 mtrs 604.00 3020.00

134407.00

PANELS FEEDER PILLER FOR EACH TRANSFORMER

OFP FOR 500KVA SUBSTATION

122

S/I/T&Commissioning of LT OUTDOOR floor mounted cubical type electrical main panel (DOUBLE FRONT WITH DOOR) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR 01 NO OF 500 KVA TRANSFORMER)

In commer- 01 number of 800Amps 4P MCCB, (Of approved make & ISI marked)Busbar- 04 numbers of 1000Amps Electrolytic copperbusbar duly sleeved by color coaded PVC sleeve &supported by suitable size DMC insulator.

Out going- (i) 01 No of 630A TP MCCB. (Ofapproved make & ISI marked)(FOR MAINCONNTROL OF ADMN)(ii) 4 No. 125 amp TP MCCB(Of approved make & ISImarked)(FOR main controller

44

Page 48: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

(iii) 6 numbers 63Amps TPN MCB (Of approved make& ISI marked)(iV) 02 No. 250 amp TP MCCB(Of approved make &ISI marked)Instrument- (i) 03 numbers phase indicating lampwith toggle switch & HRC fuse.(ii) 01 set of 0-800Amps Ameter with selecter switch &CTS.(iii) 01 set of 0-500 voltmeter with selecter switch.iv)04 nos 40 Ka SP VSD with 32A SP MCB. 1.0 set 467413.00 467413.00 NB- This panel should have proper earth bysuitable rated copper flat.

Total 467413.00

123

Supplying, Erection, Fixing, connection & testing of LED Street Light of reputed make & ISI marked as approved LED Luminarie 25 Watt with 9 meter maintenance freeG.I POLE with braket including MCB box for inspection as required.(SINGLE ARM)

41.0 Sets 21347.00 875227.00

124

Supplying, Erection, Fixing, connection & testing of LED Street Light of reputed make & ISI marked as approved LED Luminarie 25 Watt with 9 meter maintenance freeG.I POLE with braket including MCB box for inspection as required.(DOUBLE ARM)

12.0 Sets 27401.00 328812.00

125

Supply of materials and installation of pipe earth electrode made out of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ termination of G.I. flat / wire with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.

4.0 Nos 4000.00 16000.00

126Excavation of all kinds of soil up to 3 meters depth incluiding refilling (Except rocky soil )

2.0 cum 213.00 426.00

127Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required.

45.0 Mtr 100.00 4500.00

STREET LIGHT SYSTEM WITH TIMER CONTROL

45

Page 49: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

128Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections etc. as required.

12.0 Mtr 917.00 11004.00

129Refilling/Back filling soft soil with borrowed within a lead of 5 K.M. etc. as required.

3.0 Cum 650.00 1950.00

CABLING

130

Supplying and laying of one number PVC insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade of approved make & of following size cables with in different types laying.

a) 3.5core x 35 sq mm (surface)(OFP TO IND. TIMERPANEL) 35.0 Mtr 338.00 11830.00

b) 4core x 10 sq mm (surface)(timer panel to pole loop)75.0 Mtr 207.00 15525.00

a-1) 3.5core x 35 sq mm (under ground includingexcavation & refilling) 65.0 Mtr 486.00 31590.00

b-1) 4 core x 10 sq mm (under ground includingexcavation & refilling) 40.0 Mtr 366.00 14640.00

a-2) 3.5core x 35 sq mm (in pipe,including supply of pipe)12.0 Mtr 331.00 3972.00

a-3) 3.5core x 35 sq mm (open duct) 35.0 Mtr 328.00 11480.00 b-3) 4core x 10 sq mm (open duct) 41.0 Mtr 203.00 8323.00 c-3) 3core x 4sq mm (open duct) 45.0 Mtr 230.00 10350.00

131Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.

3.5 core x35sq mm 12.0 Nos 245.00 2940.00

132

Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials.

62.0 mtrs 120.00 7440.00

133

Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling.

50 mm dia 18.0 mtrs 453.00 8154.00

PANELS

134

S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type MCB ENCLOSURE made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR UPS) with 20A TPN MCB 01 NO.

2.0 sets 3252.00 6504.00

46

Page 50: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

AREA LIGHT,TIMER PANEL FOR STREET LIGHT

135

S/I/T&Commissioning of LT OUTdoor WALL/FLOOR mounted double door type cubical type electrical main panel ( light ) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing.

In commer- 01 number of 63A 4P MCB. (of approved make & ISI marked)Busbar- 04 numbers of 70Amps Electrolytic copperbusbar duly sleeved by color coaded PVC sleeve &supported by suitable size DMC insulator.

Out going- (i) 01 number TIME SWITCH,01 NO OF70A TP POWER CONTACTOR FALLOWED BY, 6-32A SP MCB-15 NOS(Of approved make & ISImarked)(FOR OUT LIGHT CIRCUIT)Instrument- (i) 03 numbers phase indicating lampwith toggle switch & HRC fuse.(ii) 01 set of 0-60Amps Ameter with selecter switch &CTS.(iii) 01 set of 0-500 voltmeter with selecter switch. 3.0 Set 48250.00 144750.00

Total 1515417.00

Total External Electrification work 3056918.70

Air conditioning system 1937203.96

Total Internal Electrification work 21674512.00

Total Electrical amount 2,66,68,634.66

INTERNAL PH WORKS

136

Supplying all materials, labour and T&P for fitting and fixing white glazed vitreous china porcelain Orissa pattern water closet of size 23" of approved make confirming to IS-2556 and top inlet for sinking into floor with 100mm PVC 'P' trap etc. including supply of necessary cement concrete for fitting the closet etc. complete in all respect in all floors including cost, conveyance and taxes of all materials etc. complete and as per PH specification and direction of Engineer-in-charge.

126.00 NOS 1958.70 2,46,796.20

47

Page 51: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

137

Supplying all materials, labour and T&P for fitting and fixing white glazed vitreous china porcelain Floor mounted coupled closets of approved make confirming to IS-2556 and top inlet for sinking into floor with 100mm PVC 'P' trap etc. including supply of necessary cement concrete for fitting the closet etc. complete in all respect in all floors including cost, conveyance and taxes of all materials etc. complete and as per PH specification and direction of Engineer-in-charge.

300.00 NOS 1846.10 5,53,830.00

138

Supplying all materials, labour and T&P for fitting and fixing white glazed vitreous china porcelain flat back urinal pan of approved make confirming to IS-2556 and top inlet for sinking into floor with 100mm PVC 'P' trap etc. including supply of necessary cement concrete for fitting the closet etc. complete in all respect in all floors including cost, conveyance and taxes of all materials etc. complete and as per PH specification and direction of Engineer-in-charge including marble partition in between urinals.

24.00 NOS 2340.20 56,164.80

139

Supplying all materials, labour, T&P and fixing standard sized shower (bath shower) of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.

355.00 NOS 840.30 2,98,306.50

140

Supplying all materials, labour and T&P for fitting and fixing white glazed vitreous china porcelain wash basin of size 450mm x 300mm of approved make confirming to IS-2556 and top inlet for sinking into floor with 100mm PVC 'P' trap etc. including supply of necessary cement concrete for fitting the closet etc. complete in all respect in all floors including cost, conveyance and taxes of all materials etc. complete and as per PH specification and direction of Engineer-in-charge.

95.00 NOS 2048.70 1,94,626.50

141

Supplying all materials, labour, T&P and fixing standard sized CP Bib cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.

389.00 NOS 540.70 2,10,332.30

48

Page 52: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

142

Supplying all materials, labour, T&P and fixing standard sized push type CP Bib cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.

72.00 NOS 540.70 38,930.40

143

Supplying all materials, labour, T&P and fixing standard sized concealed stop cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.

355.00 NOS 869.30 3,08,601.50

144

Supplying all materials, labour, T&P and fixing standard sized pillar cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.

96.00 NOS 755.00 72,480.00

145

Supplying all materials, labour, T&P and fixing standard sized Long body CP Bib cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.

379.00 NOS 849.60 3,21,998.40

146

Supplying all materials, labour, T&P and fixing standard sized two way CP Bib cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.

302.00 NOS 1077.20 3,25,314.40

147

Supplying all materials, labour, T&P and fixing standard sized 8mm dia Hand shower (Health Faucet) of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.

302.00 NOS 424.50 1,28,199.00

49

Page 53: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

148

Supplying all materials, labour, T&P and fixing standard sized paper holder of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.

302.00 NOS 1392.20 4,20,444.40

149

Supplying all materials, labour, T&P and fixing standard sized 15mm dia Angular Stop cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.

177.00 NOS 468.60 82,942.20

150

Supplying all materials, labour, T&P and fixing standard sized CP soap Dish holder of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.

472.00 NOS 314.80 1,48,585.60

151

Supplying all materials, labour, T&P and fixing standard sized CP towel rail - 450x20 of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.

120.00 NOS 663.10 79,572.00

152

Supplying all material, labour T&P and fixtures for providing and fixing of stain less steel sink of size600x450x225mm of approved make with its components like 40mm CP waste of cat no ALD 709, 40mm waste pipe etc, including all requisite fixing materials complete as per the PH specification and direction of Engineer-in-charge

55.00 NOS 3210.80 1,76,594.00

153

Supplying all materials, labour, T&P and fixing standard sized sink cock of florentine single lever quaterturn of approved make complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.

55.00 NOS 1162.80 63,954.00

50

Page 54: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

154

Providing and fixing circular type stainless steel jalli (grating) with hole for floor /nahani trap etc complete as per PH specification and direction of the engineer in charge

866.00 NOS 65.80 56,982.80

155

Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer in charge

104.00 NOS 507.00 52,728.00

156

Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to woden plugs with CP screws as per specification and direction of the Engineer in charge

104.00 NOS 1847.60 1,92,150.40

157

Supply all materials, labour,T&P for fitting and fixing of dual cock flushing valve 32mm of approved make Flush Valve Concealed -or equivalent type of approved make complete with all parts and internal fittings of approved make with ISI mark and supplying of necessary brackets, screws etc 32mm dia flush bend, 40 mm dia 450mm long PVC water connecting pipe brass union nuts at each end as per PH specification all complete as per direction of Engineer-in-charge.

300.00 NOS 4375.60 13,12,680.00

158

Supply all materials, labour,T&P for fitting and fixing of Flush cock lever type 32mm having Concealed -or equivalent type of approved make complete with all parts and internal fittings of approved make with ISI mark and supplying of necessary brackets, screws etc 32mm dia flush bend, 40 mm dia 450mm long PVC water connecting pipe brass union nuts at each end as per PH specification all complete as per direction of Engineer-in-charge.

128.00 NOS 2682.10 3,43,308.80

51

Page 55: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

159

Supplying all materials, labour, T&P and fittings and fixing of Poly Propelene white double layer water storage Tank of approved make confirming to IS 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc including hoisting upto terrace level and placing the tank to the required position etc all complete as per PH specification and direction of Engineer-in-charge. (To provided with brick masonary guard walls which will be paid separately)

a 1000 Ltr 12.00 NOS 13211.60 1,58,539.20 b 2000 Ltr 12.00 NOS 24509.50 2,94,114.00 c 3000 Ltr 19.00 NOS 32239.30 6,12,546.70 d 4000 Ltr 8.00 NOS 42425.60 3,39,404.80

160

Supplying all materials, labours, T&P and fitting and fixing of the following size of CPVC pipe confirming to IS 15778 certification mark with socket and screw joints in walls and floors including supplying of required number of fittings of approved make including cutting threads to pipes and pipes to length, including wastage,etc for fitting to the walls with supply of holder ats, clamps, fixing wooden plugs in walls, including testing of pipe line for water tightness complete as per IS specification including cost, conveyance and taxes of all materials all complete as per PH specification and direction of Engineer-in-charge.

a 15 mm dia 1638.00 RM 123.00 2,01,474.00 b 20 mm dia 234.00 RM 145.20 33,976.80 c 25 mm dia 623.74 RM 185.90 1,15,953.27

d 32 mm dia 156.80 RM 238.90 37,459.52 e 40mm dia 376.00 RM 330.70 1,24,343.20 f 50 mm dia 234.00 RM 496.80 1,16,251.20

161

Supplying all materials, labours, T&P, fitting and jointing of 50mm dia GI pipe confirming to IS 1239, medium class having IS mark of approved make with socket and screw joint including supply, fitting and fixing of required number of IS certified fitting, cutting threads to pipe and pipes to length including wastage providing necessary offsets and lay screw with extra socket and jam nut including fixing to wall and floors with supply of holder bats, clamps, fixing wooden plugs in walls complete as per PH specification and direction of Engineer-in-charge.

728.00 RM 243.70 1,77,413.60

52

Page 56: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

162

Supplying all materials, labour, T&P, fitting & fixing of different size brass / GM Full way Valve of approved make including supply of all necessary jointing materials such as red lead paint, yarns etc. including cost, conveyance & taxes of all materials, T&P etc. all complete as per P.H. specification and direction of the Engineer-in-charge.

a 25mm Dia 480.00 NOS 625.40 3,00,192.00 b 32mm Dia 222.00 NOS 993.30 2,20,512.60 c 40mm dia 92.00 NOS 1295.30 1,19,167.60 d 50mm dia 46.00 NOS 1945.70 89,502.20

163

Supplying all materials,labours,T&P for cutting holes through existing brickwork including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/PVC pipes and fittings etc all complete as per PH specification and direction of Engineer-in-charge.

872.00 NOS 31.00 27,032.00

164

Supplying all materials,labours,T&P for cutting holes through existing RCC floors & roofs including making good the damages for taking GI pipes and fittings/PVC pipes and fittings etc all complete as per PH specification and direction of Engineer-in-charge.

433.00 NOS 94.60 40,961.80

165

Supplying all materials, labours, T&P for water proofing treatment of floor and side surface of the sunken slab area of approved quality as per PH specification and direction of Engineer-in-charge. (MR)

326.78 SQM 550.00 1,79,729.55

166

Supplyng all materials, labour, T&P for construction of brick masonary Gulley trap chamber of size 250mm x 250 mm with CI gulley trap, by Fly ash brick masonry in CM (1:4), CP (1:6) with 150mm x 150mm CI grating including labour and materials for fitting and fixing 100mm dia square mouth CI gully trap with supply of all jointing materials and encasing the gully trap with a block of CC (1:4:8) with 25mm size hard stone metal all complete with providing and fixing of 250mm x 250mm precast RCC cover slab including cost, conveyance, taxes of all materials to site complete as per the PH specification and direction of Engineer-in-charge.

438.00 NOS 1263.60 5,53,456.80

TOTAL 94,27,553.04

53

Page 57: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

EXTERNAL PH WORKS

GREY WATER SUPPLY & WATER SUPPLY

167

Supplying all materials, labour, T&P, fitting & fixing of 50mm dia brass / GM Full way Valve of approved make including supply of all necessary jointing materials such as red lead paint, yarns etc. including cost, conveyance & taxes of all materials, T&P etc. all complete as per P.H. specification and as per the direction of the EIC.

92.00 NOS 1945.70 1,79,004.40

168

Supplying all materials, labour, T&P, fitting and fixing GI pipe & fittings of approved make confirming to IS- both below and above ground level / floor and on walls including supply of bobbins, nains, screws, wooden cleats, pipe clips as per requirement, including earth work in excavation and fitting, including cuting walls and floor and making good the damages with cement concrete (1:4:8) with hard granite chips, incluidng scaffolding wherever necessary all complete as per the PH specification and direction of the Engineer-in-charge.

50mm dia 1456.00 RM 243.70 3,54,827.20 65mm dia 899.60 RM 359.40 3,23,316.24

169

Supplying all materials, labour, T&P, fitting and fixing CI pipe & fittings of approved make confirming to IS- both below and above ground level / floor and on walls including supply of bobbins, nains, screws, wooden cleats, pipe clips as per requirement, including earth work in excavation and fitting, including cuting walls and floor and making good the damages with cement concrete (1:4:8) with hard granite chips, incluidng scaffolding wherever necessary all complete as per the PH specification and direction of the Engineer-in-charge.

100mm dia 501.80 RM 1516.30 7,60,879.34 150mm dia 182.00 RM 1892.00 3,44,344.00

170

Supplying all materials, labour, T&P and fitting and fixing of CI water sluice valve of different Dia confirming to the relevant IS specification and dimension including fixing it in position along the pipeline with supply of all required materials such as rubber insertion, nuts & bolts including cost of all materials, taxes, and duties, transportation charges from store to site etc all complete as per the direction of Engineer-in-charge.

54

Page 58: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

100mm Dia 39.00 NOS 3760.00 1,46,640.00 150mm Dia 20.00 NOS 5658.30 1,13,166.00

171

Supplying all materials & labour, T&P and constructing brick masonary chamber for water sluice valve, single air valve & non return valve with Fly ash brick masonary in cement mortar (1:4) as per approved drawing and specification CC (1:4:8) with 4cm size hard granite metal on the bed, 12mm cement plaster (1:6) to inside and cement flush pointing (1:6) to outside surface with 100mm thick RCC M20 cover slab with 20mm hg chips using required quantity of tor steel, centring and shuttering to the slab and dismantling it after 31 days of casting, filling the outside cavity with excavated materials, watering, curing including cost, conveyance, taxes of all materials, labour charges for cutting, bending, binding and tying the grills in proper position etc all complete as per drawing, design and direction of Engineer-in-charge.

Sluice Valve Chamber (0.75x0.75x0.7mtr) 36.00 NOS 8566.40 3,08,390.40

172

Providing & fixing of CI body non return valve of approved make with high tensile bress rising stem suitable for the system pressure as per IS 780

125mm Dia 30.00 NOS 2194.30 65,829.00 150mm Dia 18.00 NOS 2700.00 48,600.00

173

Supplying all materials, labour, T&P, fitting & fixing of different size bourden type pressure gauge of reputed make (0-10 kg/sqcm) with valves, piping, fitting of approved make including supply of all necessary jointing materials such as red lead paint, yarns etc. including cost, conveyance & taxes of all materials, T&P etc. all complete as per P.H. specification and as per the direction of the Engineer-in-charge. (MR)

4.00 SET 3000.00 12,000.00

174

Supplying all materials, labour, T&P and fitting and fixing of double air valve of 50mm Dia confirming to the relevant IS specification and dimension including fixing it in position along the pipeline with supply of all required materials such as rubber insertion, nuts & bolts including cost of all materials, taxes, and duties, transportation charges from store to site etc all complete as per the direction of Engineer-in-charge.

50.00 NOS 4111.90 2,05,595.00

55

Page 59: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

175

Supply, installation, testing and commisioning of automatic star delta control panel suitable for 10 HP pumpset including MS box fitted with main switch ,contactor, single phasing preventer, timer, selector switch, voltmetre, ammeter etc and connection with motor inside the sump with suitable cable etc complete as per the Direction of Engineer-in-charge. (Excluding power supply)(MR)

4.00 SET 15000.00 60,000.00

176

Supplying all materials, labour, T&P laying, fitting and fixing of different dia CI specials confirming IS specification in the pipe line trenches in proper position providing lights, barriers, pegs, thread, end testing the joints etc all complete but excluding cost of lead joints as per the direction of Engineer-in-charge.

A 100mm Diai 90 Degree Bend 24.00 NOS 1966.70 47200.80ii 45 Degree Bend 8.00 NOS 1875.20 15001.60iii 250x200 Tee 12.00 NOS 2424.10 29089.20

200x150 Tee 8.00 NOS 2424.10 19392.80iv Socket tail piece 24.00 NOS 3064.40 73545.60A 1500mm Diai 90 Degree Bend 16.00 NOS 2266.00 36256.00ii 45 Degree Bend 8.00 NOS 2175.00 17400.00iii 200x200 Tee 8.00 NOS 2725.00 21800.00iv Socket tail piece 8.00 NOS 3375.00 27000.00

177

Supply, installation, testing and commisioning of horizontal centrifugal pump set of approved make having discharge 30 m3 per hour and 35-40mtr head including installation of pump set (10 HP) with suitable base plate and foundation inside the sump, delivery arrangement with suitable GI or MS pipe providing valves fittings etc and connection within 10mtr distance etc complete as per the Direction of Engineer-in-charge. (MR) @6500/ hp

4.00 SET 65000.00 260000.00

178

Supplying all materials, labour, T&P and fittings and fixing of Poly Propelene white double layer water storage Tank of approved make confirming to IS 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc including hoisting upto terrace level and placing the tank to the required position etc all complete as per PH specification and direction of Engineer-in-charge. (To provided with brick masonary guard walls which will be paid separately)

56

Page 60: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

a 1000 Ltr 8.00 NOS 13211.60 105692.80b 2000 Ltr 6.00 NOS 24509.50 147057.00c 3000 Ltr 11.00 NOS 32239.30 354632.30d 4000 Ltr 3.00 NOS 42425.60 127276.80

4203936.48

179

Earthwork in hard Soil upto 1.50 mtr depth in excavation of foundation trenches for columns, basement, tie beams, walls and steps in all kinds of soil including moorum, hard stony earth and earth mixed with boulders except sheet rocks and boulders requiring blasting with initial leads and lifts including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with all leads and lifts, T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, designing including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge.

2368.74 cum 119.87 283933.34

180

Earthwork in excavation beyond 1.50 mtr depth in excavation of foundation trenches for columns, basement, tie beams, walls and steps with all leads and lifts including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with all leads and lifts, T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, designing including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge.

254.69 cum 216.47 55132.80

181

Earthwork in excavation beyond 3.0 mtr depth in excavation of foundation trenches for columns, basement, tie beams, walls and steps with all leads and lifts including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with all leads and lifts, T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, designing including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge.

In hard rock 170.73 cum 313.07 53448.64

STP (250KLD) (Civil work),Richarge pit, Infiltration chamber,Inspection chamber,Man hole,Sewerage pipe line trench,Rain water pipe line trench,UGR, Drain

57

Page 61: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

182

Supplying and filling the Foundation & Plinth with clean coarse river sand of approved quality from approved quarry, laying in layers not exceeding 150mm thick, watering and ramming including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for the work complete as per direction of the Engineer-in-charge.

1049.04 cum 549.70 576654.65

183

Providing & laying cement concrete of prop. (1:4:8) in foundation bed and floors using 40mm nominal size down graded, screened, washed hard black crusher broken granite metal of approved quality & from approved quarry including laying in the layers not exceeding 100 mm thick, hoisting, lowering, laying, watering and curing etc. complete to the required levels including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for the work complete and as per direction of Engineer-in-charge.

211.69 cum 3517.70 744654.74

184

R.C.C. work of M-20 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using and as per specification of MORTH (4th edition) crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills.

Foundation,Wall,Beam & Column,Roof Slab, 487.13 cum 4542.70 2212893.48

58

Page 62: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

185

Rigid & smooth centering & shuttering for R.C.C. works including false works with all necessary bracing and tiles and supports with leveling centering covered with plastic sheet with provisions for necessary holes and pockets for electrical conduits, pipes, P.H. pipes, for hooks or boxes, switch and board insert plates, clamps and extension bars etc., including dismantling the same after the required interval from the date of casting including cost of all materials, labour,Labour cess , conveyance, loading and unloading, taxes, royalties, scaffolding, watering, curing, sundries, tools and plants, etc., complete as per the direction of the Engineer-in-charge.

(i) R.C.C. foundation & plinth band, footing,base of column mass concrete.

171.72 sqm 99.30 17051.796

(ii) R.C.C. walls & fins including attached pillasters

1121.46 sqm 479.90 538186.49

(iii) R.C.C. beam & column girders etc.144.38 sqm 546.20 78860.36

(iv) R.C.C. Lintel & Sill18.34 sqm 240.30 4407.70

(v) In floor & roof slab,landings,balconies, projections,sunshades and chajjas upto 4.3m. Height.

359.01 sqm 364.60 130896.77

186

Cutting,straightening coiled or bent up HYSD/TMT Reinfocement Bars welding or jointing if necessary ,bending, binding,tying the grills as required for R.C.C. works,providing Fan Hooks where necessary and hoising,lowering and placing the same tin proper position according to the approved eesigns and drawings in all floors including cost, conveyance, loading, unloading and taxes or HYSD/TMT Reinforcement Bars and Binding wieres of 18 to 20 gauge required for the work cost of all labour,T&P and scaffolding complete in all respect as directed by the Engineer-in-charge(Payment will be made according to the actual/proper weight of HYSD/TMT Reinforcement Bars and Binding wires consumed in the particular work only)

404.77 Qntl 5441.00 2202333.50

59

Page 63: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

187

Providing 12mm. thick cement plaster with cement mortar of mix (1:4) in all floors cement and with screened and washed sharp sand for mortar with neat cement punning finished smooth to brick/RCC walls after racking out the joints including watering and curing complete with cost, conveyance, loading and unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P, scaffolding required for the work etc. complete in all respect as directed by the Engineer-in-Charge.

933.82 sqm 122.80 114672.48

188

Providing 12mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary) including watering and curing,rounding of corners etc. complete with cost,conveyance, loading, unloading, royalities and taxes of all materials,cost of all labour,T&P,sundries and scaffolding required for the work etc. as directed by the Engineer-in-charge.

1476.97 sqm 97.50 144004.09

189

Supplying and fixing 900mm dia SFRC cover without frame for manhole including cost of all materials, T&P, labour etc complete as per direction of Engineer-in-charge.

13.00 nos 1100.00 14300.00

190Finishing walls with water proofing cement paint of approved shade on new work Two coat to give an even shade

457.78 sqm 25.48 11665.28

191

Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.

374.01 cum 87.13 32587.58

192Disposal of surplus excavted materials by mechanical means from the work side etc. complete. upto 5km. Lead

849.15 cum 162.90 138326.33

60

Page 64: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

193

Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12 c.m x 8 c.m in Foundation & Plinth having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge.

228.31 cum 3538.30 807814.59

194

Supplying, fitting and fixing of M.S grills, grill gates with top and bottom rails, ( as per I.S. specification and as per approved drawings ) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damaged walls/ structures with cement concrete (1:2:4) with black hard crusher broken granite stone chips of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and curing including cost, conveyance, loading, unloading, stacking, royalties and taxes of all materials, cost of all Labour, Labour cess ,Sundries, T&P required for the work etc.complete as per the direction of Engineer in charge ( W.I. / M.S. windows grills, grill gates, collapsible gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows, staircase and parapet railings square bar along with required nos. of nails and screws and other required materials of approved quality and approved size shall be supplied by the contractor at his own cost.)

1125.00 kg 72.53 81596.25

195

Providing 16mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary)including watering and curing,rounding of corners etc. complete with cost,conveyance,loading, unloading,royalities and taxes of all materials,cost of all labour,T&P,sundries and scaffolding required for the work etc. as directed by the Engineer-in-charge.

120.24 sqm 137.20 16496.93

61

Page 65: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

196

Painting with synthetic enamel paint over a coat of primer of approved colour, shade and brand on New wood work /steel work in two or more coats as required to give an even shade including an under coat of suitable primer of approved brand and manufacturer including cost of all materials with taxes and transportation, loading, unloading, scaffolding, all labour, Labour cess, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge including filling gaps with putties, scrapping, sand papering and cleaning the surface to make free from rusts, dusts and oily substances before applying primer etc. complete.

58.84 sqm 130.90 7701.83

197

Supplying all materials, labour, T&P for fitting and fixing of puddle collar of 300mm dia of approved make etc complete as per direction of Engineer-in-charge.

9.00 nos 10000.00 90000.00

198

Supplying all materials, labour, T&P for fitting and fixing of vent pipe of approved make etc complete as per direction of Engineer-in-charge.

6.00 nos 2000.00 12000.00

199

2.5cm. thick artificial stone flooring with punning with cement concrete (1:2:4) laid to proper slope in two layers bottom layer being 3/4” (20mm) thick with 1/4” to 3/4” size down graded hard black broken granite stone chips of top layer being 1/4”(6mm) thick with 1/4”(6mm) down graded hard black broken granite stone chips of approved quality and from approved quarry including watering, curing for 7 days with cost, conveyance, royality of all materials and labour with T&P required for the work with royalities, taxes etc.complete in all floors as per direction of Engineer-in-charge.

24.50 sqm 223.30 5470.85

Add dry bore well drill & pipe lowering etc with filters and casings etc

904500.00

62

Page 66: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

200

Providing 16mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary)including watering and curing,rounding of corners etc. complete with cost,conveyance,loading, unloading,royalities and taxes of all materials,cost of all labour,T&P,sundries and scaffolding required for the work etc. as directed by the Engineer-in-charge.

536.31 sqm 137.20 73581.57

201Add cost of Charcoal,Gravel , sand and MS grating(Ls) 84000.00

202 C.I. Man hole cover 60cm. Dia including frame54600.00

203 Iron foot steps of 16 mm dia. Bar36120.00

204 UPVC Pipe 110 mm of 6 kg /cm2 Pr 845.00 Mtr 396.30 334873.50UPVC Pipe 160 mm of 6 kg /cm2 Pr 445.00 Mtr 442.40 196868.00

205 100mm NP  HUME PIPE 284.00 Mtr 474.54 134768.14150mm NP  HUME PIPE 416.00 Mtr 532.18 221387.28200mm NP  HUME PIPE 186.00 Mtr 604.28 112395.20

206

Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12 c.m x 8 c.m in superstructure having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge.

16.44 cum 3571.60 58726.03

207

Supplying all labour,materials, T&P and laying to level and slope and jointing with CM (1:2) of concrete pipes (class-NP-2) reinforcement light duty non presure pipes conforming to IS-456 with concrete and ends prepared for collar joints of 300mm dia RCC Hume Pipe with all complete excluding earth work in trench.

40.00 mtr 837.26 33490.42

63

Page 67: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

10620400.60

STP (250KLD) (Mechanical work)

208

Supply, installation, testing & commissioning of 3 Nos Stainless Steel Perforated, 25mm,10mm, Course & 6 mm Fine Bar Screen with suitable lifting arrangement (size 2600 mm Long x 1000 mm width approx)

3.00 LS 20000.00 60000.00

209Supply, installation, testing & commissioning of 1 no Oil Skimmer of manual rack arm mechanism .

1.00 LS 7000.00 7000.00

210

Supply of MS hot dip galvanized puddle flanges in accordance to BS:10 table D as required to be provided (in the structural slab and wall) of various diameters. Puddle flanges shall be provided for all the structural component of the STP. The installation of the puddle flanges shall be carried out by the Civil contractor in accordance to the Civil GA drawing (to be prepared by the STP contractor) at the required levels & position; under the supervision of the STP contractor

4.00 LS 1700.00 6800.00

211

Supply of plastic encapsulated step/foot rest (@ 300 mm c/c) with polypropelene compound injection molded around 12 mm dia (Fe-415) steel reinforcing bar. Provision of the foot rest is envisaged in various tanks/ components of the STP for the purpose of accessability. The installation of the foot rest shall be done by the civil contractor as per civil GA drawing

19.00 NOS 450.00 8550.00

212

Supply, installation, testing & commissioning of CI medium duty manhole cover with frame for the feasibility of access in the tank Size : 1200 x 1000 (175 kg)

12.00 NOS 12000.00 144000.00

213

Supply of vent pipes of 100 mm dia with mosquito proof grating suitable for the ventilation purpose of the various tanks along with air vent pipe as per detailed drawings & technical specifications.

3.00 NOS 2000.00 6000.00

64

Page 68: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

214

Supply, installation, testing & commissioning of electronic type level indicator, instrumation and controller for automatic operation of the system with high/low level alarm complete with auxillary NO/NC contacts. Contractor shall ensure submission of detailed GA drawings (Plan & Section), P & I diagram, schematic diagram for the above mentioned component and additional component if so required for the complete working of the STP.

1.00 SET 27000.00 27000.00

215

S/F horizontal end suction type centrifugal pumping (semiopen impellor) set with C.I. casing. Bronze Impeller, SS shaft with mechanical rotary shaft seal directly coupled to motor suitable for operation on 400/440 volts, 3 phase 2900 RPM. TEFC 'electric motor mounted on a common channel baseplate with coupling guard, pressure guage, G.M. isolation cock, suitable Vibration eliminator pads of approved design and cement concrete foundation complete as required. 1 set = 2 Nos.(1 working + 1 standby)

Capacity 10 M3/hr each (feed Pass / Sludge Re-circulation) 2.00 SET 47000.00 94000.00Head 12-15 MtsRPM 2900

216

Supply, installation, testing & commissioning of non clogging type pumps capable of handling solids upto 15 mm having C.I casing & C.I impeller complete with all accessories, motor of required capacity, Pressure gauge on delivery line with isolation cock, level controller (with wiring) to control the level of sump automatically. Pumps shall have following duty:

2.00 SET 47000.00 94000.00

217

Supply, installation, testing & commissioning of non clogging type pumps capable of handling solids upto 15 mm having C.I casing & C.I impeller complete with all accessories, motor of required capacity, Pressure gauge on delivery line with isolation cock, level controller (with wiring) to control the level of sump automatically. Pumps shall have following duty:

Capacity 10 M3/hr each (feed Pass / Sludge Re-circulation) 2.00 SET 47000.00 94000.00Head 12-15 MtsRPM 2900

218 Air diffusion system shall include the following:

65

Page 69: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

A

Suitable fixed type fine bubble diffused air blowers with ss floculator ,having motorized reduction gear and ss impeller of adequate capacity and size of 10 rpm max as per detailed drawing and specifications

1.00 SET 85000.00 85000.00

B

2 Nos. twin type rotary air blowers with 1450 rpm suitable motor (1W + 1Sb) capable of delivering 600 cum/hr (2 nos. ) of free air at 0.4 kg/cm2 driven through “V” belt or directly coupled through flexible coupling to a TEFCmotor of suitable HP Suitable for 415 ± 10% volts, 3 phase, 50 cycles A/C supply. (Make- usha/eqv) 1set= 2 Nos ( 1 working + 1 standby)

2.00 SET 180000.00 360000.00

C

Air piping shall comprise of pipes droppers with SS complete with all fittings such as tees, crosses, plugs, sockets, elbows, reducers, supports & clamps, puddle flanges etc cutting chases & making good. Contactor to submit detailed P & I indicating their proposal

1.00 SET 77000.00 77000.00

DSuitable air grid in SS -304 only for SAFF module with dome diffusers.

1.00 LOT 182000.00 182000.00

E

SAFF Module as per std specification and detailed drawing and technical spec, quantity required as designed (approx 22m3) with support rest etc

1.00 LOT 167000.00 167000.00

F

Hexagonal Tube settler with MSEP rack support and open able bracket /MH and support frame for clarifier unit of size 1000 mm long and with end locking arrangement ,the inclination of 51’ is required ,end lock sud have the surface locking arrangement in rack etc (min approx 14 m3)

1.00 LOT 187000.00 187000.00

219

UASB Unit having suitable Provision for 4 sampling points , Two unit drainage system, bottom collection system, and gas exhaust with top cover on outer side ,while inner side with air breaker arrangement and water collection and disposal arrangement. suitable designed as per detailed drawings and approval of site engineer /project incharge.

1.00 LOT 90000.00 90000.00

66

Page 70: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

220Providing and fixing all piping (as described below) and isolation control valves for making the system complete.

1.00 LOT 84000.00 84000.00

221Providing and fixing all piping (as described below) and isolation control valves for making the system complete.

1.00 LOT 88000.00 88000.00

222 TERTIARY TREATMENT PLANTSupplying, installing, testing and commissioning of horizontal single/multistage centrifugal filter feed pump complete in SS impeller CI casing . Each pump shall have TEFC 2900 RPM three phase electric motor. The pump shall have cast iron head, base plate SS Shaft/ Impeller/ Intermediate chamber. Pump shall be provided with mechanical seal. The pump shall be suitable for auto/ manual operation. of capacity 15 M3/hr @ 25 MWC.(1 W + 1 St by ) Suitable back washing of the system with pump for filters as required (2 W+ 1 stand by) one of the above

2.00 SET 32000.00 64000.00

223

Providing, fixing, testing & commissioning of CPA water filtration plant MMF (suitable for 3.5 Kg/Sqcm working pressure) complete with initial charge with sand /silex media , 2" MPV prahar (imported) valves with built in frontal pipe work with back wash system, pressure gauge at inlet, outlet and back wash (each with isolation cock), valves, fittings associated works.

Pr Vessel MOC – CPA Pentair 1.00 NOS 245000.00 245000.00Pr Vessel dia/hos –36"X72" TSS 100Mg/LBack Wash Period 12 Hrs.Operating Pressure 3 Kg. per sq.cmTest Pressure 7.5 Kg. Sq.cm.Capacity 12000 Lts/Hr

224

Providing, fixing, testing & commissioning of CPA water filtration plant ACF (suitable for 3.5 Kg/Sqcm working pressure) complete with initial charge with sand /silex ,Carbon media , 2" MPV prahar (imported) valves with built in frontal pipe work with back wash system, pressure gauge at inlet, outlet and back wash (each with isolation cock), valves, fittings associated works.

Pr Vessel MOC – CPA Pentair 1.00 NOS 285000.00 285000.00Pr Vessel dia/hos –36"X72" Back Wash Period 12 Hrs.Operating Pressure 3 Kg. per sq.cm

67

Page 71: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

Test Pressure 7.5 Kg. Sq.cm.Capacity 12000 Lts/Hr

225

Supply, installation, testing and commissioning of filter press mechanically operated with hydraulic press and recceeding type PP filter press type plates 610mm Sq and cloths with feed pump ( sump pump ) with 15-30 head and 10-20 m3/h 2 No.( 1W + 1s) interconnecting piping and poly dosing system.

Unit flow : 10 LPM ( 1 W + 1 St By ) 1.00 SET 287000.00 287000.00

226

Supply, installation, testing & commissioning of Hypochloride dosing system for tertiary water treatment with 500 L . HDPE/PVC tank with lid etc Unit flow : 10 LPM ( 1 W + 1 St By ) 2.00 NOS 27000.00 54000.00

227

Supply, installation, testing & commissioning of poly electro type dosing system comprising of 200 ltrs HDPE/FRP tank gravity feeding type pump and SS agitator complete with motor.

1.00 SET 17000.00 17000.00

228

Supply, installation, testing & commissioning of bacteria type dosing system comprising of 200 ltrs HDPE/FRP tank gravity feeding type pump and air agitator (pvc piping ) complete.

3.00 SET 7000.00 21000.00

229

Supply, installation, testing & commissioning of Alum type dosing system comprising of 200 ltrs HDPE/FRP tank gravity feeding type pump and SS agitator complete with motor.

1.00 SET 17000.00 17000.00

230

Approval from pollution board at initial & various other stages of works including preparation of report/drawings as per pollution board requirement, arrangement of raw sewage for testing & commissioning. Contractor shall include the cost of all chemicals (consumed during testing & commissioning and the cost of such items of works which are not explicitly mentioned above, but are mandatory to have pollution board approval.

1.00 LOT 30000.00 30000.00

231 ELECTRICAL INSTALLATION FOR STP

68

Page 72: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre shall be fabricated out of 14 gauge CRCA sheet steel in form in 3b formation with reinforcement of suitable size angle iron, channel ‘T’ sections irons and/or flats wherever necessary. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel before fabrication. Cadmium Plated hardware shall be used in fabrication of panels. Quoted rates shall inclusive of cables (in accordance to specification) with earthing from panel to each motor / equipment.

STP Motor Control CentreIncoming Distribution panel with bus bar etc as stdrequired.

A 150 amps or as suitable MCCB with the followingaccessories:

B 0-125 to amps 96 x 96 mm square electronic ammeter withselector switch and 125./5 amps 10 VA CL:1 CTs. 2 Set

Phase indicating lamps shall be protected by 2 amp SPMCB 3 Sets

C Bus Bar200 amps TPN cupper bus bar or as suitable required withheat shrinkable insulation sleeves.Outgoing

D 2 Nos TP MPCB for 5 HP direct on line starter and outgoing feeders to sewage transfer pumps (including 1 no.standby). Each compartment shall contain direct operated(0-30) A ammeter with auto/manual selector switch andindicating lamp with MCB’s for ‘ON/OFF/TRIP’ status ofmotor.status of motor.

E 2 Nos TP MPCB for 15 HP direct on line starter and outgoing feeders to Membrane suction pumps for byepass/sludge recirculation (including 1 no. standby). Eachcompartment shall contain direct operated (0-30) Aammeter with auto/manual selector switch and indicatinglamp with MCB’s for ‘ON/OFF/TRIP’ status of motor.statusof motor.

F 2 No 32 amps DB MPCB for 5 HP direct on line starter andout going feeders to chemical cleaning pump. Eachcompartment shall contain direct operated (0-30)A ammeterwith auto/manual selector switch and indicating lamp withMCB’s for ‘ON/OFF/TRIP’ status of motor.

G 2 nos. TP MPCB for 50 HP Star Delta starter and outgoingfeeder to air blowers for EQT/aeration tank (including 1 no.standby) . Each compartment shall contain CT operatedammeter of suitable amps range with auto/manual selectorswitch and indicating lamps with MCB’s for‘ON/OFF/TRIP’ status of motor

69

Page 73: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

H 2 nos. 32 amps TP MPCB for 15 HP Star Delta starter andoutgoing feeder to air blowers for MBR tank (including 1 no.standby) . Each compartment shall contain CT operatedammeter of 0-63 amps range with auto/manual selectorswitch and indicating lamps with MCB’s for‘ON/OFF/TRIP’ status of motor

I 2 Nos. 32 amps TP MPCB 7.5 HP direct on line starter andoutgoing feeder to flushing water pump for Zone-1(including 1 no. standby). Each compartment shall containdirect operated (0-32) A range ammeter with auto/manual selector switch and indicating lamps with MCB’s for ON/OFF/TRIP status of motor.

J 2 Nos. 32 amps TP MPCB 3.0HP direct on line starter and outgoing feeder to pant room drainage pumps (including 1 no. standby) . Each compartment shall contain CT operated ammeter of (0-32) amps range with auto/manual selector switch and indicating lamps with MCB’s for ‘ON/OFF/TRIP’ status of motor

K 2 Nos. 32 amps TP MPCB 3.0 HP direct on line starter andoutgoing feeders to softener feed pumps. Eachcompartment shall contain direct operated (0-32) A rangeammeter with auto/manual selector switch and indicatinglamps with MCB’s for ‘ON/OFF/TRIP’ status of motor

L 2 Nos. 40 amps TP MPCB for7.5 HP direct on line starter (including 1 No. standby) and outgoing feeders to soft water lifting pumps. Each compartment shall contain direct operated 0-40 amps range ammeter with selector switch, auto/manual selector switch and indicating lamps with MCB’s for ‘ON/OFF/TRIP’ status of motor.

Single phase supply to dosing pumps Spare MCB’s of following capacities:40 amps TPN MPCB (10kA) 2 Nos.32 amps TPN MPCB (10kA) 2 Nos. 2 Nos.16 amps TPN MPCB (10kA) 1 No.

Necessary cable alleys, internal / cabling, wiring, cabling from MCC to various pumps / equipment and interlocking, earthing for all equipment shall also included

Notes:All MCCBs shall be of suitable breaking capacity andsuitable for motor duty application.All motor starter shall be provided with Automatic levelcontroller.Provision shall be made for providing potential freecontacts to all pumps starters for connection to BAS

MCC for STP as described above 1.00 SET 85000.00 85000.00

232 CABLE & CABLE TRAYSSupplying & laying of following 1100 volt grade PVC sheathed aluminum/copper conductor armoured cables as per specification in existing trenches, cable trays, ducts over bed of sand, clamped to wall with suitable clamps, saddles fixing bolts including connecting testing and commissioning. as site suitable quantities as per site.

A 4 core 2.5 sq. mm copper cable 150.00 RM 300.00 45000.00B 4 core 4 sq. mm copper cable 50.00 RM 430.00 21500.00

70

Page 74: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

C 3 core 2.5 sq. mm copper cable 100.00 RM 240.00 24000.00D 3 core 4 sq. mm copper cable 100.00 RM 340.00 34000.00E 3 core 6 sq. mm copper cable 100.00 RM 470.00 47000.00

233Supply and fixing of perforated type GI cable trays with supports, hangers, fastners of the following sizes as per specification.

A 200 mm x 40 x 40 x 2 mm thick 30.00 RM 5000.00 1,50,000.00 B 200 mm x 40 x 40 x 2 mm thick 20.00 RM 5000.00 1,00,000.00 C 150 mm x 25 x 25 x 2 mm thick 22.00 RM 3000.00 66,000.00

234 EARTHINGSupply and fixing of following bare GI tapes / wires including all necessary fixing accessories and effecting connections as per specifications.

A 25 x 6 mm thick GI strip. 90.00 RM 107.00 9630.00B 8 SWG GI wire 100.00 RM 30.00 3000.00

Total 3466480.00

FIRE FIGHTING WORKS

235

Supplying , fixing and testing CI sluice valves conforming to IS 780 including making of necessary screwed joint/flanged joint and also including cost of jointing materials etc. complete as required as per PN 1.6 tested upto 24kg/cm2 pressure

4.00 Nos 3760.00 15040.00

236

Supplying fixing and testing CI double flanged non return valves conforming to IS :5312 ( part-1) including making necessary flanged joint etc. complete100mm dia 4.00 Nos 3913.30 15653.20

237

Supplying laying, jointing and testing of MS pipe heavy duty of 'C'class confirming to IS 1239 and necessary fittings, like bends, tees, elbow, flanges, reducers, expanders, gaskets, with nuts, bolts and washers confirming to IS, flanged/weldied joints providing "l" angle support for resting of pipes and providing MS clamps including painting red colour with over one coat of zinc oxide etc. complete

100mm Dia 285.00 RM 1212.60 345591.00

238Providing and fixing 100mm dia black flanges as per "E" with asbestos gasket, nut, bolts, washers complete.

4.00 Nos 1241.00 4964.00

239

Supplying , fixing and testing single headed gun metal hydrant valve oblique type with 100 NB flanged inlet and 63mm female oblique outlet with blank cap and chain as per IS 5290with IS mark etc. complete

71

Page 75: VOLUME – III Price Bid/ BOQengineeringprojects.com/Tender/UploadFiles/3056_Vol-III.pdfFly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12

Sl no

BOQ Description Qty Unit Rate Amount

8.00 Nos 7200.00 57600.00

240

Supplying and erectioning hose boxes made of 18 hauge, MS sheet of size 800x600x250 mm with glaze front door painted red colour outside and white inside etc, complete.(MR)

4.00 Nos 3200.00 12800.00Total 4,51,648.20

Total Internal PH works 94,27,553.04

External PH works 1,82,90,817.08

Fire fighting works 4,51,648.20

Total PH amount S.Total 2,81,70,018.32

72