TENDER DOCUMENT TENDER No.: NRO/CON/ 662/ 527 FOR CONSTRUCTION OF MAIN ENTRANCE GATE, BOUNDARY WALL & LANDSCAPING, ARCHITECTURE BUILDING AND CANTEEN BUILDING AT NIT, RAIPIR (CHATTISGARH) FOR NATIONAL INSTITUTE OF TECHNOLOGY, RAIPUR (CHATTISGARH) VOLUME – III PRICE BID (REVISED) EXECUTING AGENCY ENGINEERING PROJECTS (INDIA) LIMITED (A GOVT. OF INDIA ENTERPRISE) Core-3, Scope Complex, 7, Lodhi Road, New Delhi-110003 TEL NO: 011-24361666, FAX NO. 011- 24363426

Transcript of VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate...

Page 1: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

TENDER DOCUMENT TENDER No.: NRO/CON/ 662/ 527

FOR

CONSTRUCTION OF MAIN ENTRANCE GATE, BOUNDARY WALL & LANDSCAPING,

ARCHITECTURE BUILDING AND CANTEEN BUILDING AT NIT, RAIPIR (CHATTISGARH)

FOR

NATIONAL INSTITUTE OF TECHNOLOGY, RAIPUR (CHATTISGARH)

VOLUME – III

PRICE BID (REVISED)

EXECUTING AGENCY

ENGINEERING PROJECTS (INDIA) LIMITED (A GOVT. OF INDIA ENTERPRISE)

Core-3, Scope Complex, 7, Lodhi Road, New Delhi-110003 TEL NO: 011-24361666, FAX NO. 011- 24363426

Page 2: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Total Amount( Rs.)

1 2 3 4 5= (3 x 4 ) 3 + 5In figures In words In figures In words

1 CIVIL WORKS1.1 As per DSR 2007

a) Excluding subhead steel items 86311996.31b) Subhead steel items (DSR Works) 2779603.57

1.2 Non DSR Itemsa) Excluding subhead steel items 2240960.00b) Subhead steel items (NON DSR Works) 44000.00

2 SANITARY & PLUMBING WORKS2.1 As per DSR 2007 4529313.872.2 Non DSR Items 869893.68

3 ELECTRICAL WORKS3.1 As per DSR 2007 3512611.853.2 Non DSR Items 3740343.00

4 FIRE FIGHTING & FIRE ALARM WORKS4.1 As per DSR 2007 0.004.2 Non DSR Items 1361850.00

5 ACCOUSTICAL CEILING WORKS IN AUDITORIUM

5.1 As per DSR 2007 0.005.2 Non DSR Items 1346469.50

6 PUBLIC ADDRESS SYSTEM WORKS6.1 As per DSR 2007 0.006.2 Non DSR Items 1231864.00

7 LIFT IN ARCHITECTURE BUILDING7.7 As per DSR 2007 0.007.2 Non DSR Items 2391550.00

8 HVAC (VRV/VRF) WORKS8.1 As per DSR 2007 0.008.2 Non DSR Items 7473650.00

Total 117834105.77 TENDER VALUE

TOTAL TENDER VALUE ( IN WORDS) : Rupees

Seal & Signature of Tenderer

SI. No.

CONSTRUCTION OF MAIN ENTRANCE GATE, BONNDARY WALL & LANDSCAPING, ARCHITECTURE BUILDING AND CANTEEN BUILDING AT NIT, RAIPUR

PRICE SCHEDULE

TO BE QUOTED BY TENDERERAmount ( - ) Below / At Par Estimated Cost

ESTIMATED COST

(Rs.) % ( - ) Below / At ParDESCRIPTION

Page 3: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

CIVIL WORKS

( PAGE : 1 TO 30 )

Page 4: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

DSR AMOUNT (Rs.)NON SCHEDULE AMOUNT (Rs.)

A TOTAL OF SUB HEAD -1 ( EARTH WORK IN EXCAVATION 848699.75 0.00

B TOTAL OF SUB HEAD -2 ( CONCRETE WORK ) 2903379.36 0.00

C TOTAL OF SUB HEAD -3 ( R.C.C WORK ) 29024453.53 0.00

D TOTAL OF SUB HEAD -4 ( BRICK WORKS ) 4775452.12 0.00

E TOTAL OF SUB HEAD - 5 ( WOOD WORKS ) 900139.74 0.00

F TOTAL OF SUB HEAD - 6 ( FLOORING WORKS ) 3972394.16 0.00

G TOTAL OF SUB HEAD - 7 ( MARBLE WORKS ) 9468949.62 0.00

H TOTAL OF SUB HEAD - 8 STONE (CLADDING) WORKS 2867136.87 0.00

I TOTAL OF SUB HEAD - 9 ( STEEL WORKS ) 2779603.57 44000.00

J TOTAL OF SUB HEAD - 10 ( ALUMINIUM WORKS ) 6468251.62 1975000.00

K TOTAL OF SUB HEAD - 11 ( ROOFING WORKS ) 284278.31 0.00

L TOTAL OF SUB HEAD - 12 ( FINISHING WORKS ) 3843036.47 265960.00

M TOTAL OF SUB HEAD - 13 ( WATER PROOFING WORKS 1875426.18 0.00

N TOTAL OF SUB HEAD - 14 (ROAD WORKS ) 18509945.54 0.00

O TOTAL OF SUB HEAD - 15 (DISMENTALLING WORKS ) 546401.52 0.00

P TOTAL OF SUB HEAD - 16 ( DRAINAGE -SOAK PIT 24051.53 0.00

Total 89,091,599.88 2,284,960.00

SL.NO. SUB-HEAD TOTAL AMOUNT (Rs.)

NATIONAL INSTITUTE OF TECHNOLOGY - RAIPURABSTRACTCIVIL WORKS

1

Page 5: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

A SUB-HEAD: I: EARTH WORK:-

1 2.31 Clearing jungle incuding uprooting of rank vegetation , grass, brush wood , trees and

saplings of girth up to 30cm measured at a height of 1m above ground level and

removal of rubbish up to a disance of 50m outside the periphery 100 Sqm 110 263.90 290.290

Earth Work in excavation by mechanical means (Hydraulic excavator) / manualmeans in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm inplan) including dressing of sides and ramming of bottoms , lift upto 1.5 m includinggetting out the excavated soil and disposal of surplus excavated soil as directedwithin a lead of 50 m. 0

02 2.8.1 all kinds of soil cum. 2191 103.40 226551

0Earth Work in excavation by mechanical means (Hydraulic excavator) / manualmeans over areas (exceeding 30 cm inn depth, 1.5 m in width as well as 10 sqm onplan) including disposal of excavated earth. Lead up to 50m and lift up to 1.5 m,disposed earth to be levelled and neatly dressed. 0

03 2.6 all kinds of soil cum. 811 101.85 82600

04 2.26 Extra for every additional lift of 1.5 m or part thereof in. 0

02.26.1 All kind of soil. cum. 150 18.90 2835

5 2.1 Excavation trenches of required width for pipes, cables, etc. includign excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m includinggetting out the exceeding soil, and then returning the soil as required, in layers notexceeding 20cm indepth including consolidating each deposited layer by ramming,watering, etc. and disposing of surplus excavated soil as directed, within a lead of50m.

2.10.1 All kinds of soil2.10.1.2 pipes, cable etc. exceedign 80mm dia. But not exceedign 300mm dia. mtr 500.00 115.05 57525

6 2.25 Filling available excavated earth (excluding hard rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20cm in depth: consolidating eachdeposited layer by ramming and watering, lead upto 50m and lift upto 1.5m. Cum. 2397.48 45.70 109565

0

BILL OF QUANTITIES

(ARCHITECTURE BUILDING + CANTEEN BLOCK + ROAD AND BOUNDARY WALL)

2

Page 6: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

7 2.27 Supplying and filling in plinth with fine sand under floors including, watering, rammingconsolidating and dressing complete. Cum. 382.94 301.50 115456

8 1.1.2 Carriage of materials including loading, unloading and stacking, upto 5 km. Cum. 754.53 76.48 577060

9 2.34 Supplying chemical emulsion in sealed containers including delivery as speciffied

Chlorpyriphos / Lindane emulsifiable concentrate of 20% ltr 169.14 174.3 29481

10 2.35 Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti termitetreatment (excluding the cost of chemical emulsion)

2.35.1 Along external wall where the apron is not provided using chemical emulsion @ 7.5 ltr/ sqm of the vertical including excavation channel along the wall and rodding etc.complete

2.35.1.1 with chlorpyriphos/ lindane E.C 20% with 1% concentration sqm 1128 6.75 7611

11 2.35.2 Along the external wall below concrete or masonry apron using chemical emulsion@ 2.25 litres per linear metre including drilling and plugging holes etc. 0

2.35.2.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. sqm 1128 10.45 117830

Total 701404.75 0.00Cost After Index 848699.75 0.00

3

Page 7: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

B SUB HEAD -2 CONCRETE WORK:-12 Providing and laying in position cement concrete of specified grade excluding the

cost of centering and shuttering - All work upto plinth level.

4.1.3 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).Cum. 18 3257 58634

04.1.8 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).

cum 824.78 2449.00 20198950

13 Centering and shuttering including strutting , propping etc. and removal of formwork for 0

04.3.3 Columns, piers, abutments, pillars, posts and struts. sqm 241.00 238.40 57454

14 Centering and shuttering including strutting , propping etc. and removal of formwork for 0

04.3.1 Foundation , footing , bases of column sqm 1410 119.25 168143

4.3.2 Retaining walls, return walls, walls (any thickness) including attached pilasters,buttresses plinth and string courses fillets etc. sqm 100 180 18040

015 Providing and fixing upto floor five level precast cement concrete string or lacing

courses, coping , bed plates , anchor blocks , plain wndow cill , shelves , louvers ,steps , staircases etc including hoisting and setting in position with cement mortar 1:3( 1 cement : 3 coarse sand ) , cost of required centering , shuttering and finishingsmooth with 6 mm thick cement paster 1 : 3 ( 1 cement : 3 fine sand ) on exposedsurfaces complete 0

04.5.1 1 :2 : 4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size )

cum 5 4814.35 240720

16 4.11 Providing and laying damp proof course 40 mm thick with cement concrete 1:2:4 ( 1

cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) sqm 30 178.05 53420

17 4.12 Extra for providing and mixing waterproofing material in cement concrete work @1kg/50kg of cement.

per 50kg cement 6 27.45 165

0

4

Page 8: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

18 4.13 Applying a coat of residual petroleum bitumen of pentration 80/100 of approved

quality using 1.7kg per square metre on damp proof course after cleaning the

surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. sqm 30 58.60 1758

19 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed by dry brickballast 40mm nominal size well rammed and consolidated and grouted with finesand including finishing the top smooth. sqm 206.54 222.65 45986

Total 2399487.07 0.00Cost After Index 2903379.36 0.00

5

Page 9: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

C SUB HEAD - 3 R.C.C WORK:-

20 5.33 Providing and laying in position machine batched, machine, mixed and machinevibrated design mix concrete of specified grade for reinforced cement concretestructural elements, excluding the cost of centring, shuttering, finishing andreinforcement, including admixture in recommended proportions (as per IS 9103) toaccelerate, retard setting of concrete improve workability without impairing strengthand durability as per direction of Engineer-In-Charge. M25 grade reinforced cementconcrete by using 410kg of cement per cum of concrete . All work upto floor V level. cum 1875 4147.40 7776325

021 Add or deduct for providing richer or leaner mixes respectively at all floor level

00

5.34.1 Providing M30 grade concrete by using 420 kg of cement per cum of concreteinstead of M25 garde B.M.C. / R.M.C cum 1 54.55 55

22 5.9 Centring and shuttering including strutting, propping etc. and removal of form for:-00

5.9.1 Foundations, footings, bases of columns, etc. for mass concrete. sqm 660.10 119.25 78717

5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth and stringcourses etc. Sqm 1006 180.40 181518

05.9.3 Suspended floors, roofs, landings, balconies and access platform. Sqm 3412 187.35 639215

05.9.4 Shelves (Cast in situ) Sqm 22 187.35 4122

05.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers. Sqm 3792 162.65 616694

05.9.6 Columns, Pillar, Piers, Abutments, Posts and Struts. Sqm 3915 238.40 933264

05.9.7 Stairs, (excluding landings) except spiral-staircases. Sqm 96 204.00 19584

05.9.13 Vertical and horizontal fins individually or forming box louvers band, facias and

eaves boards. Sqm 300 285.55 856650

23 5.22 Reinforcement for R.C.C. work including straightening, cutting, bending, placing inposition and binding all complete. 0

0

6

Page 10: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

5.22.6 Thermo-mechanically treated bars. Kg. 310514 42.70 132589470

24 5.11 Extra for additional height in centring , shuttering where ever required with adequatebracing , propping etc including cost of de shuttering and decentring at all levels ,over a height of 3.5 m for every additional height of 1 metre or part thereof ( planarea to be measured ) 0

5.11.1 Suspended floors , roofs , landings, beams and balconies ( plan area to be measured) Sqm 3701 106.20 393046

Total 23987151.68 0.00Cost After Index 29024453.53 0.00

7

Page 11: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

D SUB HEAD - 4 BRICK WORK :-

25 Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in:-

6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum. 666 2121.75 14128990

26 6.4.2 Brick work with F.P.S brick of class designation 75 in superstructure above plinth levelupto floor V level in all shapes and sizes in cement mortar 1:6 (1 cement : 6 coarsesand). Cum. 710 2357.40 1674257

027 Half brick masonary with F.P.S bricks of class designation 75 in foundation and plinth

in : 00

6.12.1 Cement mortor 1:3 (1 cement : 3 coarse sand) sqm 1480 289.60 428608

6.12.2 Cement mortor 1:4 (1 cement : 4 coarse sand) Sqm 1132 270.35 3060360

28 6.15 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every thirdcoarse of half brick masonary (with F.P.S. bricks) Sqm 2612 47.80 124854

Total 3946654.65 0.00Cost After Index 4775452.12 0.00

8

Page 12: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

E SUB HEAD -5 WOOD & PVC WORKS :-

299.1 Providing wood work in frames of doors, windows, clerestory windows and other

frames, wrought framed and fixed in position :

9.1.1 Second class teak wood cum 6 52090.00 312540

30 9.20 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I)decorative type, core of block board construction with frame of 1st class hard woodand well matched teak 3 ply veneering with vertical grains or cross bands and faceveneers on both faces of shutters.

9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.Sqm 118 1473.50 173351

031 9.23 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth

on all edges of shutters (over all area of door shutter to be measured) Over item no.9.20 and 9.21. Sqm 118 284.55 33476

032 9.24 Extra for providing vision panel not exceeding 0.1 sum in all type of flush doors (cost

of glass excluded) (overall area of door shutter to be measured) : 00

9.24.1 Rectangular or square. Sqm 12 99.90 11990

33 9.70 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steelscrews etc. complete : 0

9.70.1 125x64x1.90 mm each 180 47.05 84690

34 9.70 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steelscrews etc. complete : 0

9.70.1 125x64x1.90 mm each 50 47.05 23530

35

9.83 Providing and fixing IS : 3564 marked Aluminium die cast body tubular type universalhydraulic door closer with necessary accessories and screws etc. complete.

each 22 610.60 134330

36

9.97 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating notless than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour orshade with necessary screws etc. complete : 0

09.97.3 200x10 mm each 71.00 52.00 3692

0

9

Page 13: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

9.97.4 150x10 mm each 26 42.75 11120

37

9.100 Providing and fixing aluminium handles ISI marked anodised (anodic coating not lessthan grade AC 10 as per IS : 1868) transparent or dyed to required colour or shadewith necessary screws etc. complete : 0

09.100.1 125 mm each 66 48.80 3221

09.100.2 100 mm each 18 35.30 635

038 9.101 Providing and fixing aluminium hanging floor door stopper ISI marked anodised

(anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed torequired colour and shade with necessary screws etc. complete. 0

09.101.1 Single rubber stopper each 50.00 19.05 953

039 9.117 Providing and fixing factory made UPVC door frame made of UPVC profile section

having an overall dimension as below (tolerance ± 1mm) with wall thickness 2.0mm± 0.2mm, corners of the door frame to be jointed with galvanized brackets andstainless steel screws, joints mitred and plastic welded. The hinge side vertical of theframes reinforced by galvanized M.S. tube of size 19 X 19mm and 1mm ± 0.1mm wallthickness and 3 nos. stainless steel hinges fixed to the frame complete as permanufacturers specification and direction of Engineer-in-charge. 0

09.117.1 Extruded section Profile size 48x40 mm. Rmt. 84 141.00 11844

9.117.2 Extruded section Profile size 42x50 mm. Rmt. 1 146.80 147

10

Page 14: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

40 9.118 Providing and fixing to existing door frames. 09.118.1 24 mm thick factory made PVC door shutters made of styles and rails of a UPVC

hollow section of size 59x24 mm and wall thickness 2 mm ± 0.2 mm with inbuilt edgingon both sides. The styles and rails mitred and joined at the corners by means of M.S.galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm andstainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S.tube of size 20x20 mm and 1 mm ± 0.1 mm wall thickness. The lock rail made up of 'H'section, a UPVC hollow section of size 100x24 mm and 2 mm ± 0.2 mm wall thicknessfixed to the shutter styles by means of plastic/ galvanised M.S. 'U' cleats. The shutterframe filled with a UPVC multi-chambered single panel of size not less than 620 mm,having over all thickness of 20 mm and 1 mm ± 0.1 mm wall thickness . The panelsfilled vertically and tie bar at two places by inserting horizontally 6 mm galvanisedM.S. rod and fastened with nuts and washers, complete as per manufacturer'sspecification and direction of Engineer-in-charge. (For W.C. and bathroom doorshutter).

Sqm 26 2190.50 56953

41

9.127 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain ingloss / matt / suede finish with high density protective surface layer and reverse sideof adhesive bonding quality conforming to IS : 2046 Type S including cost ofadhesive of approved quality.

9.127.2 1.0 mm thick. sqm 235 512.30 120540

Total 743917.14 0.00Cost After Index 900139.74 0.00

11

Page 15: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

F SUB HEAD - 6 FLOORING WORKS

42 11.23 Marble stone flooring with 18mm thick marble stone (sample of marble shall beapproved by Engineer-in-charge) over 20 mm (average) thick base of cementmortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurryincluding rubbing and polishing complete with :

11.23.3 Agaria White Sqm 175 1673.55 2928710

11.23.5 Udaipur green marble Sqm 10 1112.55 111260

11.24 Extra for prefinished nosing to treads of steps of marble stone. metre 270 105.20 284040

11.25 Extra for marble stone flooring in treads of steps and risers using single length upto2.00 metre . Sqm 41 122.35 5016

043 Kota stone slab flooring over 20mm (average) thick base laid over and jointed with

grey cement slurry mixed with pigment to match the shade of the slab includingrubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4coarse sand) 0

011.26 25mm thick. Sqm 2196 694.40 1524678

044 Kota stone stone slabs in risers of steps, skirting, dado and pillars laid on 12mm

(average) thick cement mortar 1:3 (1 cement : 3 coarse sand and jointed with greycement slurry mixed with pigment to match the shade of the slabs, including rubbingand polishing complete. 0

011.27 Kota Stone - 25mm thick Sqm 311 676.75 210469

045 11.36 Providing and fixing 1st quality ceramic glazed tiles conforming to IS: 13753 of

minimum thickness 5mm of approved make in all colours, shades, design and printsexcept begundy, bottle green, black, of any size as approved by Engineer-In-Charge in skirting, risers of steps and dados over 12mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg. per sqm.including pointing in white cement mixed with pigment of matching shadecomplete. Sqm 307 556.60 170876

046 11.37 Providing and laying Ceramic glazed floor tiles 300 x 300mm (thickness to be

specified by the manufacturer) of 1st quality conforming to IS:13755 of approvedmake in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20mm thickcement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with whitecement and matching pigment etc. complete. Sqm 93 598.65 55674

12

Page 16: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount 0

47 11.41.2 Providing and laying polished Vitrified tiles in different sizes (thickness to be spcifiedby manufacturers) with water absorption's less than .08% and confirming to IS : 15622pf approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4)1 cement : 4 coarse sand) including grouting the joints with white cement andmatching pigments etc, complete. 0

011.41.1 Size of tile 50x50 cm Sqm 14 966.35 13529

011.41.2 Size of tile 60x60 cm Sqm 875 1031.85 902869

48 11.20 Chequerred precast cement concrete tiles 22mm thick in basement floor & rampfloor jointed with neat cement slurry mixed with pigment to match the shade of tilesincluding rubbing and cleaning etc. complete on 20mm thick bed of cement mortar1:4 (1 cement : 4 coarse sand) 0

11.20.2 Medium shade using 50% white cement 50% grey cement. Sqm 110 613.25 67458

Total 3282970.38 0.00Cost After Index 3972394.16 0.00

13

Page 17: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

G SUB HEAD -7 MARBLE WORK:-

49 8.2 Providing and fixing 18 mm thick mirror polished (PREMOULDED AND PREPOLISHED),machine cut, granite stone for kitchen platforms , vanity counters, window sills, faciasand similar location of required size of approved shade, laid over 20mm thick basecement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement ,mixed with matching pigment, epoxy touch-ups including rubbing, curing , mouldingand polishing to edge to give high gloss finish etc complete at all levels.

8.2.1 Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble.

8.2.1.1 Area of slab upto 0.50 sqm. Sqm 378 1309.40 4949530

50 8.2.2 Granite of any colour and shade 0

8.2.2.1 Area of slab upto 0.50 sqm sqm 30 2480.20 744060

8.2.2.2 Area of slab over 0.50 sqm. Sqm 718 2543.65 18263410

51 8.3 Extra for providing edge moulding to 18-20mm thick marble stone counters, vanitiesetc. including machine polishing to edge to give high gloss finish etc. complete asper design approved by Engineer-In-Charge. 0

08.3.1 Marble Work metre 1 57.90 58

08.3.2 Granite Work metre 10 97.60 976

52 8.4 Extra for fixing marble/ granite stone over and above corresponding basic items, infacia and drops of width upto 150mm with epoxy resin based adhesive includingsleaning etc complete. metre 21 106.80 2243

053 8.5 Extra for providing opening of required size & shape for wash basins / kitchen sink in

kitchen platform, vanity counters and similar location in marble / Granite / stonework including necessary holes for pillar taps etc. including rubbing and polishing ofcut edges etc. complete.

Each opening 18 151.00 2718

054 8.6 Mirror polishing on marble work / granite work / stone work where ever required to

give high gloss finish complete. Sqm 57358 94.20 54031240

14

Page 18: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

55 8.10 Providing and fixing stone slab table rubbed, edges rounded and polished of size75x50 cm deep and 1.8 cm thick fixed in urinal partitions by cutting a chase ofappropriate width with chase cutter and embedding the stone in the chase withepoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate 6 mm nominal size) as per direction of Engineer-in-charge andfinished smooth. 0

08.10.2 Granite Stone of approved shade. Sqm 8 2595.00 20760

0Total 7825578.20 0.00Cost After Index 9468949.62 0.00

15

Page 19: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

H SUB HEAD - 8 STONE (CLADDING) WORK:-

56 7.40 Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang sawcut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed tostructural steel frame work and/ or with the help of cramps, pins etc. and sealing thejoints with approved weather sealant as per Architectural drawing and direction ofEngineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shallbe paid for separately.)

7.40.1 Red sand stone. sqm 179 1323.40 236889

7.40.2 White sand stone sqm 360 1382.35 497646

57 7.42 Providing and fixing adjustable stainless steel cramps of approved quality and ofrequired shape and size adjustable with stainless steel nuts bolts and washer (totalweight not less than 260 gms) for dry stone cladding fixed on frame work at suitablelocation including making necessary recesses in stone slab, drilling required holes etccomplete as per direction of the Engineer-in-charge. each 6000 272.50 1635000

Total 2369534.60 0.00Cost After Index 2867136.87 0.00

16

Page 20: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

I SUB HEAD - 9 STEEL WORK:-

58 10.10 Fixing standard steel glazed doors, windows and ventilators in walls with 15x3mm lugs10 cm long embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugsand screws or rawl plugs and screws or with fixing clips or with bolts and nuts asrequired, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws (only steel windows withlugs, glass panes cut to size and glazing clips or metal beading with screws, shallbe supplied by department free of cost.)

kg 110 23.20 2552

59 10.14 Providing and fixing pressed steel door frames confirming to IS: 4351 manufacturedfrom commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lockjamb, bead and if required angle threshold of mild steel angle of section 50x25mm,or base ties of 1.25mm pressed mild steel welded or rigidly fixed together bymechanical means, adjustable lugs with split end tail to each jamb including steelbutt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers asspecified and applying a coat of approved steel primer after pre-treatment of thesurface as directed by Engineer-in-charge:

10.14.3 Profile E metre 176 303.00 53240

60 Steel work welded in built-up sections / framed work including cutting hoisting, fixingin position and applying a priming coat of approved steel primer using structural steel etc. as required.

10.25.2 In gratings, frames, guard bar, ladders, railings, brackets, gates & similar works. kg. 30610 51.20 15672320

61 Providing and fixing hand rail by welding etc. to steel ladder railing, balcony railing &

staircase railing including applying a priming coat of approved steel primer. 00

10.26.1 MS Tube Kg 10622 62.35 6622820

17

Page 21: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

62 10.1 Structural work in single section fixed with or without connecting plate includingcutting , hoisting , fixing in position and applying a priming coat of approved steelprimer all complete. kg 110 42.15 4637

063 10.6 Supplying and fixing rolling shutters of approved make, made of required size M.S.

laths interlocked together through their entire length and jointed together at the endby end locks mounted on specially designed pipe shaft with brackets, side guidesand arrangements for inside and outside locking with push and pull operationcomplete including the cost of providing and fixing necessary 27.5cm long wiresprings grade No.2 and M.S. top cover of required thickness for rolling shutters.

010.6.1 80x1.25mm M.S. laths with 1.25 mm thick top cover. sqm 6 1208.45 7251

64 NS Item same as 9.04 but for using stainless steel instead of mild steel for stair case railing,handrail kg. 80 550.00 44000

Total TOTAL 2297193.03 44000.00Cost After Index 2779603.57 44000.00

18

Page 22: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

J SUB HEAD - 10 ALUMINUM WORKS

65 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugsand screws or with fixing clips, or with expansion hold fasteners including necessaryfilling up of gaps at junctions, at top, bottom and sides with required PVC/neoprenefelt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminium snap beading forglazing / panelling, C.P. brass / stainless steel screws, all complete as perarchitectural drawings and the directions of Engineer-in-charge. (Glazing andpanelling to be paid for separately) :

21.1.1 For fixed portion.

21.1.1.3 Polyester powder coated aluminium (minimum thickness of polyester powdercoating 50 micron) kg 1908.16 312.40 596109

066 21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/

pivots and making provision for fixing of fittings wherever required including the costof PVC / neoprene gasket required (Fittings shall be paid for separately).

00

21.1.2.3 Polyester powder coated aluminium (minimum thickness of polyester powdercoating 50 micron) kg 3584.12 332.85 1192974

067 21.2 Providing and fixing 12mm thick Pre-laminated particle board flat pressed three layer

or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panellingfixed in aluminium doors, windows shutters and partition frames with C.P. brass /stainless steel screws etc. complete as per architectural drawings and directions ofengineer-in-charge. 0

021.2.2 Pre-laminated particle board with decorative lamination on both sides. sqm 5 812.60 4063

068 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and

partitions etc. with PVC/ neoprene gasket etc. complete as per the architecturaldrawings and the directions of engineer-in-charge . (Cost of aluminium snapbeading shall be paid in basic item) : 0

21.3.2 With float glass panes of 5.50 mm thickness sqm 3597.02 673.55 24227760

19

Page 23: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

69 21.4 Providing and fixing double action hydraulic floor spring of approved brand andmanufacture IS : 6315 marked, for doors including cost of cutting floors as required,embedding in floors and cover plates with brass pivot and single piece M.S. sheetouter box with slide plate etc. complete as per the direction of Engineer-in-charge.

0

21.4.1 With stainless steel cover plate each 10 1733.50 173350

70 21.8 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work byproviding weather silicon sealant over backer rod of approved quality as perarchitectural drawings and direction of Engineer-in-charge complete. 0

21.8.1 Upto 5mm depth and 5 mm width metre 882 58.85 519060

71 21.13 Providing and fixing 100mm brass locks (best make of approved quality) foraluminium doors including necessary cutting and making good etc. complete. each 8 208.35 1667

072 21.16 Providing and fixing aluminium round shape handle of outer dia 100mm with SS

screws etc. Complete as per direction of Engineer-in-charge 0

21.16.3 Polyester powder coated minimum thickness 50 micron aluminium . each 166 52.30 8682

73 9.51 Providing and fixing fly proof galvanised MS wire gauge to windows and clerestorywindows using galvanised MS wire gage with average width of aperture 1.4mm inboth directions with wire of dia 0.63mm

9.51.2 With 12mm mild steel U beading sqm 3597.02 291.95 1050151

20

Page 24: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

74 NS Aluminium Composite Panel

Providing and fixing 4mm thick Aluminium composite panel (0.5mm PVDF coatedAluminium skin on top & bottom plus 3mm thick polyethylene core) cladding ofapproved shade of required profile to Brick/ Concrete wall/ MS frame, canopy,parapet, coping, bends, pergola or any type architectural feature whereverrequired as shown in drawing, either segmental curved or straight in plan whereverspecified with extruded aluminium sections, angle cleats, weather sealants, stainlesssteel screws, rivets, fasteners, Galvanised brackets (Galvanising to be doneconforming to IS:4759-1996 upto 610 gms. per sqm, 80-90 micron thickness), drillingand fixing the cladding to either masonry/ reinforced cement concrete/ MSstructural frame work including making grooves of required size applying non staining weather selant, backer rod, all necessary accessories etc. complete in all respectsas per drawing.Note: The contractor shall submit fabrication drawings for approval of the ProjectManager. (MS frame work for this work shall be measured and paid separately)The fabrication work shall start only after approval of the fabrication drawings. Anychange required in the fabrication drawings shall be carried out at no extra cost.

Sqm 395 5000.00 1975000

Total TOTAL 5345662.50 1975000.00Cost After Index 6468251.62 1975000.00

21

Page 25: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

K SUB HEAD - 11 ROOFING:-

75 12.21 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4stone aggregate 10mm and down gauge) including finishing with cement mortar1:3 (1 cement : 3 fine sand) as per standard design :

12.21.1 In 75x75mm deep chase metre 683 67.35 460000

76 12.22 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size)over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1cement : 3 coarse sand) and a coat of neat cement rounding the edge sandmaking and finishing the outlet complete. each 16 108.00 1728

077 12.43 Providing and fixing Unplasticised -PVC pipe clips of approved design to

Unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs,screwed with M.S. screws of required length including cutting brick work and fixing incement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc.complete. 0

012.43.1 75 mm each 10 79.50 795

012.43.2 110 mm each 26 96.90 2519

078 12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm

diameter and weighing not less than 440 grams. each 27 23.40 6320

22

Page 26: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

79 12.45 Providing and fixing at all height false ceiling including providing and fixing of framework made of special sections power pressed from M.S. sheet and galvanised inaccordance with zinc coating of grade 350 as per IS : 277 and consisting of anglecleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mmcentre to centre one flange fixed to the ceiling with dash fastener 12.5mmdiax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm ofrequired length, and other end of angle hanger being fixed with nut and bolts to G.I.channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which theceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mmeach having clips of 10.5mm at 450mm centre to centre shall be fixed in a directionperpendicular 0to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire

at every junction including fixing the gypsum board with ceiling section andperimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mmlong, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at450mm centre to centre with 25mm long drive-all screws @ 230mm interval includingjointing and fixing to a flush finish of tapered and square edges of the board withrecommended filler, jointing tapes, finisher and two coats of primer suitable forboard as per manufactures specification and also including the cost of makingopenings for light fittings, grills, diffusers, cutouts made with frame of perimeterchannels suitably fixed all complete as per drawing and specification and directionof the Engineer in Charge but excluding the cost of painting with :

12.45.1 12.5 mm thick tapered edge gypsum board conforming to IS: 2095- Part I, Sqm 365 502.10 183267

Total TOTAL 234940.75 0.00Cost After Index 284278.31 0.00

23

Page 27: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

L SUB HEAD - 12 FINISHING:-

80 13.1 12mm cement plaster of mix :-

13.1.2 a) 1:6 ( 1 cement : 6 fine sand) Sqm 7457 67.65 5044680

81 13.2 15mm cement plaster on the rough side of single or half brick wall of mix 013.2.2 a) 1:6 (1 cement : 6 fine sand) Sqm 7457 78.55 585750

082 13.16 6mm cement plaster to ceiling to mix :- 0

013.16.1 a) 1:3 (1 cement : 3 fine sand) Sqm 3276 62.15 203597

083 13.11 18mm thick cement plaster in two coats under layer 12mm thick cement plaster 1:5

(1cement :5 coarse sand) finish with top layer 6mm thick cement plaster 1:6 (1cement : 6 fine sand). Sqm 4222 111.15 469254

084 White washing with lime to give an even shade:- 0

13.37 a) New Work (three or more coats) Sqm 193 6.75 13030

85 Distempering with Oil Bound washable distemper of approved brand andmanufacture to give an even shade 0

13.41 a) New work (Two or more coats ) over and including priming coat with cementprimer Sqm 7666 41.55 318506

086 Finishing walls with water proofing cement paint of required shade : 0

13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sum). Sqm 8698 30.80 2678980

87 Painting with synthetic enamel paint of approved brand and manufacture to givean even shade:- 0

013.61 a) Two or more coats on new work Sqm 1220 35.35 43127

088 13.72 Washed stone grit plaster on exterior walls of height upto 10 M. above level in two

layers,under layer 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) furrowingthe under layer with scratching tool,applying cement slurry on the under layer @ 2 Kgof cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement : 1/2coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all aroundas per approved pattern including scrubbing and washing, the top layer withbrushes and water to expose the stone chippings ,complete as per specification anddirection of Engineer-in - charge (Payment for providing grooves shall be madeseparately) Sqm 30 262.20 7866

24

Page 28: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

89 14.72 Providing and fixing double scaffolding system (cup lock type) on the exterior side,upto seven story height made with 40mm dia. M.S. tube 1.5 m centre to centrehorizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tubechallies, M.S. clamps and M.S. staircase system in the scaffolding for working platformetc. and maintaining it in a serviceable condition for the required duration asapproved and removing it there after .The scaffolding system shall be stiffened withbracings, runners, connection with the building etc wherever required for inspectionof work at required locations with essential safety features for the workmen etc.complete as per directions and approval of Engineer-in-charge .The elevationalarea of the scaffolding shall be measured for payment purpose .The payment will bemade once irrespective of duration of scaffolding. (To be used for maintenancework judicially . necessary deduction for scaffolding in the existing item to be done.)

sqm 250 82.70 20675

90 13.45 Finishing walls with textured exterior paint of required shape13.45.1 New work ( two or more coats applied @ 3.28 ltr / 10sqm ) over and including base

coat of water proofing cement paint applied @ 2.20kg/ 10sqmsqm 7830 96.25 753619

91 NS Acrylic Emulsion Paint

Providing and applying three or more coats of acrylic emulsion paint of approvedbrand, manufacturer and shade to give a smooth finish on new plastered surfacesover a coat of approved primer including the cost of preparing the surfaces withfilling materials (putty), along with sand papering wherever required, scaffoldingetc. complete.

Two or more coats on new work Sqm 1168 110.00 128480

92 NS POP punning

Providing and applying plaster of paris (super fine quality) punning with minimumthickness of 6mm and finish the surface smooth in line and level including scrapingand hacking the existing finished surfaces, scaffolding etc. complete as per drawing.

Sqm 1168 100.00 116800

25

Page 29: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

93 NS POP cornice

Providing and making decorative plaster of paris (super fine quality) cornice (cast insitu), moulding, flutings etc in the required profile and smooth in line and level to theentire satisfaction of Project Manager complete as per design and drawing.

Width above 75 mm to 100 mm rmt 188 110.00 20680

Total 3176063.20 265960.00Cost After Index 3843036.47 265960.00

26

Page 30: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

M SUB HEAD - 13 WATER PROOFING WORKS

94 22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroometc., by applying cement slurry mixed with water proofing cement compoundconsisting of applying : a) First layer of slurry of cement @ 0.488 kg/sum mixed with water proofing cementcompound @ 0.253 kg/sum. This layer will be allowed to air cure for 4 hours.b) Second layer of slurry of cement @ 0.242 kg/sum mixed with water proofingcement compound @ 0.126 kg/sum. This layer will be allowed to air cure for 4 hoursfollowed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners,junctions of pipes and masonry with polymer mixed slurry.

Sqm 168 143.85 24167

95 22.7 Providing and laying integral cement based water proofing treatment includingpreparation of surface as required for treatment of roofs, balconies, terraces etcconsisting of following operations:a) Applying a slurry coat of neat cement using 2.75 kg/sum. of cement admixed withwater proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height includingcleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm sizewith 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with waterproofing compound conforming to IS : 2645 and approved by Engineer-in-chargeover 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand )admixed with water proofing compound conforming to IS : 2645 and approved byEngineer-in-charge to required slope and treating similarly the adjoining walls upto300 mm height including rounding of junctions of walls and slabs.

c) After two days of proper curing applying a second coat of cement slurry using2.75kg/ sum of cement admixed with water proofing compound conforming to IS :2645 and approved by Engineer-in-charge.d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1cement :4 coarse sand) admixed with water proofing compound conforming to IS :2645 and approved by Engineer-in-charge including laying glass fibre cloth ofapproved quality in top layer of plaster and finally finishing the surface with trowelwith neat cement slurry and making pattern of 300x300 mm square 3mm deep.

22.7.1 e) The whole terrace so finished shall be flooded with water for a minimum period oftwo weeks for curing and for final test. All above operations to be done in order andas directed and specified by the Engineer-in-Charge : Sqm 2818 541.50 1525772Total 1549938.99 0.00Cost After Index 1875426.18 0.00

27

Page 31: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

N SUB HEAD - 14 ROAD WORKS:-

96 16.1 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne

capacity after excavation earth to an average of 22.5 cm depth dressing to camber

and consolidating with roller including making good the undulations etc. and re-

rolling the sub grade and disposal of surplus earth upto 50 metres. Sqm 17325 33.90 5873180

97 Supplying and stacking of graded stone aggregate at site of size range 00

16.3.1 90mm to 45mm cum 3465 742.30 25720700

16.3.2 63mm to 45mm cum 1733 768.45 13317240

16.3.3 53mm to 23.4mm cum 1733 810.55 14046830

98 16.4 laying spreading and compacting stone aggregate of specified sizes to WBMspecifications including spreading in uniform thickness , hand picking, rolling with 3wheeled road / vibrator roller 8-10 tonne in stages to proper grade and camber,applying and brooming requisite type of screening /binding material to fill upintertices of coarse aggregate watering and compacting to the required density. cum 6931 192.55 1334564

099 16.30 Providing and applying tack coat using hot straight run bitumen of grade 80/ 100

including heating the bitumen, spraying the bitumen with mechanically operatedspray unit fitted on bitumen boiler, cleaning and preparing the existing road surfaceas per specifications : 0

16.30.1 On W.B.M. @ 0.75 Kg / sum. Sqm 17325 23.90 4140680

100 16.33 2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone chippings of13.2mm and 11.2mm size respectively per 100 sum. and 52 kg. and 56 kg. of hotbitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectivelyincluding a tack coat with hot straight run bitumen including consolidation with roadroller of 6 to 9 tonne capacity etc. complete. (tack coat to be paid for separately) : 0

16.33.1 With paving Asphalt 80/100 heated and then mixed with solvent at the rate of 70grams per kg of asphalt. Sqm 34650 100.35 3477128

0

28

Page 32: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

101 16.41 Providing and laying seal coat over prepared surface of road with bitumen heatedin bitumen boiler fitted with the spray set spraying using 98 kg of bitumen of grade80/100 and blinding surface with 0.90cum of stone aggregate of 6.7 mm size(Passing 11.2mm sieve and retained on 2.36mm sieve) per 100 sum of road surfaceincluding rolling and finishing with power road roller all complete. sqm 17325 50.00 866250

0102 16.68 Providing and laying 60mm thick factory made cement concrete interlocking paver

block of M -30 grade made by block making machine with strong vibratorycompaction and of approved size and design/ shape laid in required colour andpattern over and including 50mm thick compacted bed of course sand, filling thejoints with coarse sand etc. all complete as per the direction of Engineer-in-charge. sqm 4920 346.35 1704042

0103 16.69 Providing and laying at or near ground level factory made kerb stone of M-25 grade

cement in position to the required line, level and curvature jointed with cementmortar 1:3 (1 cement : 3 coarse sand ) including making joints with or withoutgrooves (thickness of joints except at sharp curve shall not to more than 5mm)including making drainage opening wherever required complete etc. as perdirection of Engineer-in-charge ( length of finished kerb edging shall be measuredfor payment ). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). cum 378 4247.70 1605631

Total TOTAL 15297475.65 0.00Cost After Index 18509945.54 0.00

29

Page 33: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. DSR Item 2007 Description. Unit. Qty. DSR Rate

(Rs.)Non DSR Rate (Rs.) DSR Amount Non DSR

Amount

O SUB HEAD - 15 DISMENTLING WORKS:-

104 15.3 Demolishing R.C.C. work manually/ by mechanical means including stacking of steelbars and disposal of unserviceable material within 50 metres lead as per direction ofEngineer-in-charge. cum 200 537.55 107510

0105 15.7 Demolishing brick work manually/ by mechanical means including stacking of

serviceable material and disposal of unserviceable material within 50 metres lead asper direction of Engineer-in-charge. 0

015.7.4 In cement mortar cum 350 310.75 108763

0106 15.18 Dismantling steel work in built up sections in angles, tees, flats and channels including

all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering andstacking within 50metres lead. kg 1100 0.85 935

0107 15.31 Dismantling tiled roofing with battens boarding etc. complete including stacking of

serviceable material and disposal of unserviceable material within 50 metres lead.Sqm 6000 32.05 192300

108 1.1.2 Disposed off material (carriage) including loading, unloading and stacking upto 5km cum 550 76.48 42064

0Total TOTAL 451571.50 0.00Cost After Index 546401.52 0.00

P SUB HEAD - 16 DRAINAGE - SOAK PIT WORKS:-

109 19.32 Making soak pit 2.5 m diameter 3.0mtr deep with 45x45 cm dry brick honey combshaft with bricks of class designation 75 and SW drain pipe 100mm diameter 1.8mlong complete as per standard design.

19.32.1 with FPS bricks each 2 9938.65 19877

Total TOTAL 19877.30 0.00Cost After Index 24051.53 0.00

30

Page 34: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SANITARY & PLUMBING WORKS

( PAGE : 1 TO 18 )

Page 35: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No. Description DSR Amount Non DSR Amount

A SANITARY FIXTURE & FITTINGS 243384.91 128238.68

B SOIL, WASTE, VENT & RAIN WATER PIPES 826536.42 734075.00

C INTERNAL / EXTERNAL WATER SUPPLY 634135.47 7580.00

D SEWERAGE & DRAINAGE SYSTEM 2825257.07 0.00

TOTAL 4529313.87 869893.68

SUMMARY OF COST

SANITARY & PLUMBING WORKS

1

Page 36: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. DSR Item 2007 Details of Works Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

A SANITARY FIXTURE & FITTINGS

1 17.3 Providing and fixing white viterous china pedestal type watercloset (European type) with seat and lid, 10 litre low level whitevitreous china flushing cistern & CP flush bend with fittings & CIbrackets, 40 mm flush bend, overflow arrangement with specialsof standard make and mosquito proof coupling of approvedmunicipal design complete including painting of fittings andbrackets, cutting and making good the walls and floors whereverrequired:

17.3.1 W.C. pan with ISI marked white solid plastic seat and lid. Each 8 3282.95 26263.60

2 NS Providing, fixing, testing & commissioning of ABS Rinsing spray withregulator of approved quality with plastic flexible pipe 1.5 m long,wall hook complete as required of approved make Cera/Jaquar/Parryware or equivalent and per Engineer in Charge

Each 8 1230.00 9840.00

3 17.1 Providing and fixing water closet water closet squatting pan(Indian Type W.C Pan) with 100mm sand cast iron 'P' or 'S' trap, 10ltrs low level, PVC flushing cistern with manually controlled device(handle lever)conforming to IS : 7231, with all fittings and fixturescomplete including cutting and making good the walls and floorswherever requiredand as per direction of Engineer -In-charge:

17.1.1 White Vitreous China Orissa pattern W.C pan of size 580 x 440 mmwith integral type foot rests. Each 12 2304.65 27655.80

4 18.49 Providing and fixing C.P. brass short body bib cock with flange ofapproved quality confirming to IS: 8931

18.49.1 15mm nomonal bore Each 24 313.10 7514.40

5 17.7 Providing and fixing wash basin with CI/MS brackets, 15mm CPbrass pillar taps, 32mm CP brass waste of standard pattern,including painting of fitting and brackets, cutting and makinggood the walls wherever required.

SCHIDULE OF QUANTITIES

2

Page 37: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. DSR Item 2007 Details of Works Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

17.7.3 White Vitreous China wash basin (oval) size550 x 400 mm withsingle 15mm CP brass pillar tap Each 16 1176.10 18817.60

17.7.4 White Vitreous China flat back wash basin size550 x 400 mm withsingle 15mm CP brass pillar tap Each 6 1044.90 6269.40

6 NS Providing and fixing of 15mm dia brass single lever mixer set forbash basin including wall flange and cutting & making good thewall as required, of approved make Cera/ Jaquar/ parrywarediamond range or equivalent as per direction of Engineer inCharge. Each 5 2582.00 12910.00

7 17.70 Providing & fixing PTMT Bottle trap for wash basin and sink

17.70.2 Bottle trap 38mm single piece moulded with height of 270mm,effective length of tail pipe 260mm from centre of the wastecoupling 77mm breadth with 25mm minimum water seal,weighing not less than 263gms. Each 24 395.25 9486.00

8 17.10 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink asper IS 13983 with CI brackets and stainless steel plug 40 mmincluding painting of fitting and brackets, cutting and makinggood the walls wherever required: Kitchen sink with drain board

17.10.1.1 510 x 1040 mm bowl depth 250mm Each 5 6154.35 30771.75

9 NS Providing, fixing, testing and commissioning of C.P. brass wall /counter mounted sink mixer with C.P. wall flange, overheadswinging spout complete as required and making good the wallas required, of approved make Cera/ Jaquar/ parryware orequivalent as per direction of Engineer in Charge. Each 5 3000.00 15000.00

3

Page 38: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. DSR Item 2007 Details of Works Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

10 17.4 Providing and fixing white vitreous china flat back or wall cornertype lipped front urinal basin of 430x260x350mmand340x410x265mm sizes respectively with automatic flushingcistern with standard flush pipe and C.P. brass spreaders with brassunion and G.I clamps complete, including painting and brakets,cutting and making good the walls and floor wherever required

17.4.1 One urinal basin with 5 litre white PVC automatic flushing cisternEach 2 2018.70 4037.40

17.4.2 Rangeof two urinal basin with 5 litre white PVC automatic flushingcistern Each 1 3393.60 3393.60

17.4.3 Range of three urinal basin with 10 litre white PVC automaticflushing cistern Each 5 4491.60 22458.00

11 NS Providing and fixing overhead shower rose with revolving joint and190 mm long heavy casted body with wall flange and pressureadjustable shower of make Jaquar Continental, parryware orequivalent as per direction of Engineer in Charge.

Each 1 740.46 740.46

12 NS Providing and fixing C.P brass 4 way divertor for concealed fittingwith built in non-returned valve with diverter handle mixer withspout and wall flange and cutting and making good the wall asrequired of make Jaquar Continental, Perryware or equivalent asper direction of Engineer in Charge. Each 1 2648.22 2648.22

4

Page 39: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. DSR Item 2007 Details of Works Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

13 18.53 Providing and fixing C.P. brass quality angle valve15 mm dia. Forbasin mixer and gyser points of approved quality, confirming to IS :8931

18.53.1 15mm nomonal bore Each 68 347.65 23640.20

14 18.52 Providing and fixing C.P. brass stop cock (concealed) of standarddesign and of approved make confirming to IS : 8931.

18.52.1 15mm nomonal bore Each 10 313.10 3131.00

15 17.71 Providing & fixing PTMT liquid soap container109mm wide,125mmhigh and 112mm distance from wall of standard shape andbrackets of the same materials with snap fittings of approvedquality and colour weighing not less than 105 gms. Each 12 164.65 1975.80

16 17.72 Providing & fixing PTMT towel ring trapezoidal shape 215 mmlong,200mm wide with a minimum distance of 37mm from wallface with concealed fitting arrangement of approved quality andcolour weighing not less than 88 gms. Each 12 149.00 1788.00

17 17.31 Providing & fixing 600x450mm beveled edge mirror of superiorglass ( of approved quality) complete with 6mm thick hard boardground fixed to wooden cleats with C.P. brass screws and washercomplete. Each 20 493.65 9873.00

18 17.34 Providing and fixing toilet paper holder

17.34.1 C.P. brass Each 8 147.10 1176.80

19 NS Providing and fixing stainless steel twin coat hook fixed to woodencleats with CP brass screws. (Make-euronics, model No. EC02) orequivalent as per direction of Engineer in Charge. Each 20 355.00 7100.00

20 NS Providing and fixing raised toilet seat with cover for handicaptoilet (Make : Presalit – Commander) Each 4 7000.00 28000.00

21 NS Providing and fixing 35 mm dia powder coated steel grab bar. Each 4 3000.00 12000.00

5

Page 40: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. DSR Item 2007 Details of Works Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

22 NS Providing and fixing solid state, no touch operting, fully hygienichand drier of approved shade with single blower, with time delay,summer & winter control, music while drying, volume ON/OFFcontrols including providing necessary brackets, cable from drierto Plug, Plug top key and lock etc, complete as required ofapproved Make-euronics/hindware/cera or equivalent as perdirection of Engineer in Charge.

Each 4 10000.00 40000.00

23 17.11 Providing and fixing white vitreous china laboratory sink withrubber plug 40mm C.P brass waste and 40mm C.P brass trap withnecessary C.P brass unions complete including painting of fittingand brackets, cutting and making good the walls whereverrequired:

24 17.11.1 Size 450x300x150mm Each 2 1446.10 2892.20

TOTAL 201144.55 128238.68Cost After Index 243384.91 128238.68

6

Page 41: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. DSR Item 2007 Details of Works Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

B SOIL, WASTE, VENT & RAIN WATER PIPES

25 17.35 Providing and fixing soil, waste and vent pipes:

17.35.1 100 mm dia

17.35.1.2 Centrifugally cast (spun) iron socketed pipe as per IS 3989. Metre 500 730.40 365200.00

26 17.35.2 75 mm

17.35.2.2 Centrifugally cast (spun) iron socketed pipe as per IS 3989 Metre 100 629.85 62985.00

27 17.37 Providing and fixing M.S holder-bat clamps of approved design tosand cast iron/sand cast iron (spun) pipe embedded in andincluding cement concrete blocks 10x10x10cm of 1:2:4 mix (1cement:2coarse sand: 4 graded stone aggregate 20mmnominal size) including cost of cutting holes and making good thewalls etc

17.37.1 For 100 mm dia pipe Each 20 65.35 1307.00

17.37.2 For 75 mm dia pipe Each 10 63.00 630.00

28 17.38 Providing and fixing bend of required degre with access door,insertion rubber washer 3 mm thick, bolts and nuts complete.

17.38.1 100 mm

17.38.1.2 Centrifugally Cast (Spun)Iron S & S pipe as per IS : 3989 Each 100 291.00 29100.00

29 17.39 Providing and fixing plain bend of required degree

17.39.1 100 mm

17.39.1.2 Centrifugally Cast (Spun)Iron S & S pipe as per IS : 3989 Each 85 236.40 20094.00

30 17.39.2 75 mm

17.39.2.2 Centrifugally Cast (Spun)Iron S & S pipe as per IS : 3989 Each 20 178.65 3573.00

7

Page 42: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. DSR Item 2007 Details of Works Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

31 17.43 Providing and fixing single equal plain junction of required degreewith access door, insersion rubber washer 3 mm thick, bolts andnuts complete.

17.43.1 100x100x100 mm

17.43.1.2 Sand cast iron S & S as per IS 3989 Each 100 489.60 48960.00

32 17.43.2 75x75x75 mm

17.43.2.2 Sand cast iron S & S as per IS 3989 Each 30 364.45 10933.50

33 17.48 Providing and fixing single unequal plain junction of requireddegree.

17.48.1.1 100x100x75 mm

17.48.1.2 Sand cast iron S & S as per IS 3989 Each 55 551.15 30313.2534 17.49 Providing and fixing double equal plain inverted branch of

required degree

17.49.1 100x100x100x100 mm

17.49.1.2 Sand cast iron S & S as per IS 3989 Each 16 496.55 7944.80

35 17.56 Providing and fixing terminal guard.

17.56.1 100 mm

17.56.1.2 Sand cast iron S & S as per IS 3989 Each 20 194.60 3892.00

36 17.56.2 75 mm

17.56.2.2 Sand cast iron S & S as per IS 3989 Each 16 177.45 2839.20

37 17.57 Providing and fixing collar

17.57.1 100 mm

17.57.1.2 Sand cast iron S & S as per IS 3989 Each 16 202.70 3243.20

38 17.57.2 75 mm

17.57.2.2 Sand cast iron S & S as per IS 3989 Each 10 146.10 1461.00

8

Page 43: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. DSR Item 2007 Details of Works Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

39 17.58 Providing lead caulked joints to sand cast iron/centrifugally cast(spun) iron pipes and fittings of diameter:

17.58.1 100 mm Each 200 126.50 25300.00

17.58.2 75 mm Each 75 107.80 8085.00

40 17.59 Providing and fixing M.S stays and clamps for sand cast iron /Centrifugally Cast (Spun) Iron Pipes iron pipes of diameter.

17.59.1 100 mm Each 30 48.25 1447.50

17.59.2 75 mm Each 15 41.55 623.25

41 17.60 Providing and fixing trap of self cleaning design with screweddown or hinged grating with or without vent arm completeincluding cost of cutting and making good the walls and floors:

17.60.1 100 mm inlet 100 mm outlet

17.60.1.1 Sand cast iron S & S as per IS 3989Each 75 544.30 40822.50

42 17.60.2 100 mm inlet 75 mm outletSand cast iron S & S as per IS 3989 Each 25 573.35 14333.75

43 NS Providing and fixing G. I. floor drain consisting of 100x50 mm G. I.elbow (grating and G. I. pipe to be paid separately), complete asper instruction as per direction of Engineer in Charge.

Each 25 570.00 14250.00

44 NS Providing and fixing Heavy class SS grating with Cockroach proofSS strainer of approved design including setting in floor withcement motor to match with floor finish as per architectrequirement suitable for waster and FT.

Size 100 mm x 100 mm Each 75 629.00 47175.00Size 150 mm x 150 mm Each 50 993.00 49650.00

9

Page 44: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. DSR Item 2007 Details of Works Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

45 NS Providing and fixing Brass floor clean out plug comprising of GIpipe, socket, elbow, extension piece caulked to pipe and castbrass plug with suitable inlet key for opening male threaded jointwith GI class C pipe & socket. Including lead / drip seal caulkedto CI pipes or CI class LA pipes complete as required.

100 mm dia Each 30 900.00 27000.00

150 mm dia Each 12 1200.00 14400.00

46 NS Providing and fixing on wall face unplasticised-Rigid PVC rainwater pipes conforming to IS:13592 Type A including jointing withleaving 10 mm gap for thermal expansion (i) single socketed pipesalong with all required fittings like tees, bends, crosses with orwithout access doors jointed with approved solvent cement asper manufacturer's recommendations, fixed to walls and ceilingswith clamps complete including cutting and making good thefloors and walls where required complete of outer diameteras perdirection of Engineer in Charge.

110 mm OD Metre 500 450.00 225000.00

160 mm OD Metre 200 650.00 130000.00

10

Page 45: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. DSR Item 2007 Details of Works Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

47 NS Providing and fixing in position G.I. pipe and fittings of heavyclass (c) conforming to IS:1239 (for waste pipe from individualfixtures to floor trap / floor drain & vent pipe) Including fixing atwall / ceiling level supported by galvanized clamps andhangers providing two coats of synthetic enamel paint ofapproved shade as per pipe colour code over a coat of primer or cutting & chasing in wall & floors, providing protection toembedded GI pipes & fittings by wrapping of 400 micronepolythene sheet over two coats of bitumen including properoverlaps in joints complete as required and making good thechase by using 1:1 cement mortar as per direction of Engineer inCharge32 mm dia. Metre 80 300.00 24000.00

40 mm dia. Metre 90 390.00 35100.00

50 mm dia. Metre 65 500.00 32500.00

48 NS Providing and fixing uPVC sloted pipe 6 kg/sqcm working presureconforming to IS:13592 including fitting and clamps complete asper direction of Engineer in Charge.

200 mm dia. Metre 150 900.00 135000.00

TOTAL 683087.95 734075.00Cost After Index 826536.42 734075.00

11

Page 46: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. DSR Item 2007 Details of Works Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

C INTERNAL / EXTERNAL WATER SUPPLY

49 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply including allCPVC plain and brass threaded fittings including fixing the pipewith clamps at 1.00 M spacing. This include jointing of pipes &fitting with one step CPVC solvent cement and the cost of cuttingchases and making good the same including testing of jointscomplete as per direction of Engineer in charge.

Internal Work - Exposed on wall

18.7.1 15 mm nominal outer dia Pipes Metre 90 97.95 8815.50

18.7.2 20 mm nominal outer dia Pipes Metre 105 115.65 12143.25

18.7.3 25 mm nominal outer dia Pipes Metre 110 150.40 16544.00

18.7.4 32 mm nominal outer dia Pipes Metre 120 196.35 23562.00

18.7.5 40 mm nominal outer dia Pipes Metre 75 275.05 20628.75

18.7.6 50 mm nominal outer dia Pipes Metre 35 418.50 14647.50

50 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply including allCPVC plain and brass threaded fittings including fixing the pipewith clamps at 1.00 M spacing. This include jointing of pipes &fitting with one step CPVC solvent cement and the cost of cuttingchases and making good the same including testing of jointscomplete as per direction of Engineer in charge.

Concealed work including cutting chases and making good thewalls etc.

18.8.1 15 mm nominal outer dia Pipes Metre 185 155.15 28702.75

18.8.2 20 mm nominal outer dia Pipes Metre 200 175.50 35100.00

18.8.3 25 mm nominal outer dia Pipes Metre 145 222.25 32226.25

18.8.4 32 mm nominal outer dia Pipes Metre 120 277.10 33252.00

12

Page 47: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. DSR Item 2007 Details of Works Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

51 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply including allCPVC plain and brass threaded fittings. This include jointing ofpipes & fitting with one step CPVC solvent cement, trenching,refilling & testing of joints complete as per direction of Engineer incharge.

External Works

18.9.4 32 mm nominal outer dia Pipes Metre 135 185.30 25015.50

18.9.5 40 mm nominal outer dia Pipes Metre 145 255.25 37011.25

18.9.6 50 mm nominal outer dia Pipes Metre 35 398.65 13952.75

18.9.7 62.50 mm nominal outer dia Pipes Metre 45 1217.80 54801.00

52 18.18 Providing & fixing ball valve (brass) of approved quality, High orlow pressure with plastic floats complete

18.18.1 15 mm nominal bore Each 35 228.35 7992.25

18.18.2 20 mm nominal bore Each 25 333.25 8331.25

18.18.3 25 mm nominal bore Each 16 385.90 6174.40

53 18.17 Providing & fixing gun metal gate valve with C.I wheel ofapproved quality, (Screwd end)

18.17.2 32 mm nominal bore Each 16 358.00 5728.00

18.17.3 40 mm nominal bore Each 18 399.00 7182.00

18.17.4 50 mm nominal obore Each 10 578.00 5780.00

18.17.5 65 mm nominal bore Each 6 831.75 4990.50

54 18.48 Providing and placing on terrace (at all floor levels polyethylenewater storage tank ISI : 12701 marked water storage tank withcover and suitable locking arrangement and making necessaryholes for inlet outlet and overflow pipes but without fittings andthe base suport for tank Per ltrs 22000 5.25 115500.00

13

Page 48: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. DSR Item 2007 Details of Works Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

55 NS Providing and fixing thermal insulation over hot water pipes with 9mm thick nitrile / polyolefin or approved equivalent thermalinsulation tubing, a elastomeric flexible material having hermeticblister closed cell structure of expanded synthetic rubber having athermal conductivity not exceeding 0.040 w/mk @ 40 deg. C overpipes with aluminium cladding / protective coating of FRPfollowing sizes including all required accessories complete as permanufacture's specifications as per direction of Engineer inCharge

15 mm nominal outer dia Pipes Metre 45 35.00 1575.00

20 mm nominal outer dia Pipes Metre 35 45.00 1575.00

25 mm nominal outer dia Pipes Metre 25 50.00 1250.00

32 mm nominal outer dia Pipes Metre 15 55.00 825.00

40 mm nominal outer dia Pipes Metre 15 70.00 1050.00

50 mm nominal outer dia Pipes Metre 15 87.00 1305.00

56 18.32 Constructing masonary chamber 30x30xx50 cm, inside with 75class designation brick work in cement mortar 1:4 ( 1 cement : ffine sand) for gate valve with C. I. susface box 100x100x75 mm(inside) with hinged cover fixed in cement concrete slab 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) necessary excavation foundation concrete 1:5:10(1cement : 5 fine sand : 10 graded stone aggregate 40 mmnominal size) and inside plastering with cement mortar 1 : 3 ( 1cement : 3 coarse sand) 12 mm thick finished with a floating coatof neat cement complete as per standard design with F. P. S.bricks Each 10 599.80 5998.00

TOTAL 524078.90 7580.00Cost After Index 634135.47 7580.00

14

Page 49: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. DSR Item 2007 Details of Works Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

D SEWERAGE & DRAINAGE SYSTEM

57 19.1 Providing, laying and jointing glazed stoneware pipes grade `A'with stiff mixture of Cement Mortar in proportion of 1:1 (1 cement :1 fine sand) including testing of joints etc. Complete.

19.1.1 100 mm diameter Metre 30 105.90 3177.00

19.1.2 150 mm diameter Metre 350 151.65 53077.50

19.1.3 200 mm diameter Metre 700 247.15 173005.00

58 19.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarsesand : 10 graded stone aggregate 40 mm nomainl size) all roundstoneware / RCC pipes including in bed concrete as per standarddesign

19.2.1 100 mm diameter S.W. pipe Metre 30 331.20 9936.00

19.2.2 150 mm diameter Metre 375 405.05 151893.75

19.2.3 200 mm diameter Metre 700 472.15 330505

59 19.3 Providing and laying cement concrete 1:5:10 (1 cement :5 coarsesand: 10 graded stone aggregate 40 mm nominal size) uptohaunches of S.W/ RCC. pipes including bed concrete as perstandard design :

19.3.5 250 mm diameter Metre 700 349.1 244370

19.3.6 300 mm diameter Metre 600 402.8 241680

60 19.6 Providing and laying non pressure NP2 class (light duty) R.C.C.pipes with collars jointed with stiff mixture of cement mortar in theproportion of 1:2 (1 cement :2 fine sand) including testing of jointsetc. complete :

19.6.2 150 mm dia RCC pipe Metre 25 202.85 5071.25

19.6.3 250 mm dia R.C.C. pipe metre 700 258.20 180740.00

19.6.4 300 mm dia R.C.C. pipe metre 600 338.75 203250.00

19.6.5 450 mm dia R.C.C. pipe metre 150 499.55 74932.50

15

Page 50: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. DSR Item 2007 Details of Works Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

61 19.4 Providing and fixing square mouth S.W. gully trap grade 'A'complete with CI Grating brick masonry chamber with bricks ofclass designation 75 and water tight C. I. cover with frame of300X300 mm size(inside) the weight of cover to be not less than4.50 kg and frame to be not less than 2.70 kg as per standarddesign

19.4.3 180x150 mm size P type

19.4.3.1 With FPS bricks class designation 75 Each 12 1036.75 12441

62 19.7 Constructing brick masonry manhole with 75 class designationF.P.S. bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) R. C.C. top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1ciment : 4 coarse sand: 8 graded stone aggregate 40 mmnominal size) inside plastering 12 mm thick with cement mortar 1:3(1 cement : 3 coarse sand) finished with floating coat of neatcement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) finished with a floating coat of neat cementcomplete as per standard design.

63 19.7.1 Inside size 90x80cm and 45 cm deep including CI Cover withframe (light duty) 455 x 610 mm internal dimensions total weight ofcover and frame to be not less than 38kg (weight of cover 23 Kgand weight of frame 15 kg)

19.7.1.2 with sewer bricks confirming to IS: 4885 Each 27 5640.5 152293.5

64 19.7.3 Inside size 120x90 cm and 90 cm deep including C.I cover withframe (heavy duty) 560 mm internal diameter, total weight ofcover and frame to be not less than 208 kg (weight of cover 108kg and weight of frame 100 kg.)

19.7.3.2 With Sewer bricks conforming to IS : 4885 Each 17 16278.1 276727.7

65 19.8 Extra for depth for manholes19.8.1 Size 90x80 cm

19.8.1.2 With Sewer bricks conforming to IS : 4885 metre 3 3401.8 10205.4

16

Page 51: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. DSR Item 2007 Details of Works Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

66 19.8.2 Size 120x90 cm19.8.2.2 With Sewer bricks conforming to IS : 4885 metre 3 4071.3 12213.9

67 19.9 Constructing brick masonry circular type manhole 0.91m innternaldia at bottom and 0.56 m dia at top in cement mortar 1:4 (1cement :4 coarse sand), in side cement plaster 12 mm thick withcement mortar 1:3 (1 cement : 3 coarse sand) finished with afloating coat of neat cement, foundation concrete 1:3:6 mix (1cement : 3 coarse sand : 6 graded stone aggregate 40 mmnominal size), making necessary channel in cement concrete 1:2:4(1 cement : 2 coarse sand: 4 graded stone aggregate 20 mmnominal size) finished with a floating coat at neat cement allcomplete as per standard design :

19.9.1 0.91 m deep with S.F.R.C cover and frame (heavy duty, HD-20grade designation) 560 mm internal diameter conforming to IS.12592, total weight of cover and frame to be not less than 182 kg.,fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand :4graded stone aggregate 20 mm nominal size) including centeringshuttering all complete. (Excavation, foot rests and 12 mm thickcement plaster at the external surface shall be paid forseparately)

19.9.1.2 With Sewer bricks conforming to IS : 4885 each 15 5347.9 80218.5

68 19.10 Extra depth for circular type manhole 0.9 m internal dia (atbottom) with beyond 0.91m to 1.67m

19.10.2 With Sewer bricks conforming to IS : 4885 metre 3 2915.9 8747.7

19.16 Providing orange colour safety foot rest of minimum 6mm thickplastic encapsulated as per IS: 10910 on 12 mm dia steel barconforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165 mmwith minimum 112 mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besidesnecessary and adequate anchoring protections on tail lenght on138 mm as per standard drawing and suitable to with stand thebend test and chemical resistance test as per specification &having manufacture's permanent identification mark to be visibleeven after fixing, including fixing in manhole with 30x20x15 cmcement concrete block 1:3:6 (1 cement: 3 coarse sand : 6 gradedstone aggregate 20 mm nominal size) complete as per design.

Each 45 182.4 8208

17

Page 52: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. DSR Item 2007 Details of Works Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

69 19.21 Making connection of drain or sewer line with existing manholeincluding breaking into and making good the walls, floors withcement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 gradedstone aggregate 20 mm nominal size) cement plastered on bothsides with cement mortar 1:3 (1 cement : 3 coarse sand) finishedwith a floating coat of neat cement and making necessarychannels for the drain etc. complete: distribution branch with G. I.main of following sizes by providing and fixing tee, includingcutting and threading the pipe etc. complete

19.21.1 For pipes 100 to 230 mm diameter each 3 164.30 492.9019.21.2 For pipes 250 to 300 mm diameter each 3 205.40 616.20

70 19.27 Constructing brick masonary road gully chamber 50x45x60 cmwith bricks of class designation 75 in cement morter 1:4 (1 cement: 4 coarse sand) including 500x450 mm precast RCC horizontalgrating complete as per standard design.

19.27.1 With F.P.S bricks Each 24 2248.35 53960.40

71 19.28 Constructing brick masonary road gully chamber 45x45x77.5 cmwith bricks of class designation 75 in cement morter 1:4 (1 cement: 4 coarse sand) including 500x450 mm precast RCC horizontalgrating complete as per standard design.

19.28.1 With F.P.S bricks Each 20 2358.00 47160.00

TOTAL 2334923.20Cost After Index 2825257.07

18

Page 53: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

ELECTRICAL WORKS

( PAGE : 1 TO 18 )

Page 54: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL. No. DESCRIPTION SCHD. AMOUNT NON SCHD. AMOUNT

INTERNAL ELECTRICAL WORKS

A MAIN DISTRIBUTION BOARD 0.00 553,000.00

B DISTRIBUTION BOARDS,MCBs & MCCBs 49,554.34 138,815.00

C MAIN & SUB MAIN CABLES 28,551.16 255,000.00

D WIRING & ACCESSORIES 3,348,084.52 0.00

E GI RACEWAY & JUNCTION BOXES (IP 44) 0.00 238,744.00

F LIGHTING FIXTURES SUPPLY & INSTALLATION 66,224.51 2,064,997.00

G EARTHING 20,197.32 0.00

EXTERNAL LIGHTING 0.00 489,787.00

TOTAL AMOUNT 3,512,611.85 3,740,343.00

ELECTRICAL WORKSSUMMARY OF COSTS

1

Page 55: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

A

1 NS

- 1 No. 400 Amp four pole Moulded Case Circuit Breaker (Icsvalue 35 KA) with built in thermal based release unit withadjustable setting .

- 500Amp TPN busbars of high conductivity electrolyticquality copper alloy.

- 1 No. digital multifunction meter (Ammeter + Voltmeter) for3 phase, 4 wire operation as per specification.

- 1 Set of RYB phase indicating lamps controlled by 2 ampMCB.

UNIT

BUSBARS

DETAILED ESTIMATENAME OF WORK : FACULITY OF ARCHITECTURE & CANTEEN BUILDING AT NIT RAIPUR

SL.No. CPWD CODE NO. SCHD. RATE NON

SCHD.RATEQTYDESCRIPTION OF ITEM

Supply, Installation, Testing & Commissioning , cubicle type bodymade out of 2mm thick CRCA sheet,totally enclosed, IP 42,floor/wall mounted with channel base frame, dust and verminproof, indoor, compartmentalised, suitable for operation on 3phase and neutral, 415 V, 50Hz AC system with extensible busbarson both sides, making interlocking arrangement betweenincomers & buscoupler breakers, including control wiring with 2.5sq mm size wires/cable, interconnection, duly powder coatedpainting etc. including supply & installation of followingswitchgears,metering instruments and accessories as perspecifications.

INTERNAL ELECTRICAL WORKS

MAIN DISTRIBUTION BOARD

Main Distribution Board - First Floor

INSTRUMENTS

INCOMER

SCHD. AMOUNT NON SCHD. AMOUNT

2

Page 56: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

UNIT

DETAILED ESTIMATENAME OF WORK : FACULITY OF ARCHITECTURE & CANTEEN BUILDING AT NIT RAIPUR

SL.No. CPWD CODE NO. SCHD. RATE NON

SCHD.RATEQTYDESCRIPTION OF ITEM SCHD. AMOUNT NON SCHD. AMOUNT

- 1 No. 250 Amp triple pole with neutral Moulded Casecircuit breaker (Ics value 25 KA) with built in thermal basedrelease unit with adjustable setting.

1 No. 125 Amp triple pole with neutral Moulded Casecircuit breaker (Ics value 25 KA) with built in thermal basedrelease unit with adjustable setting.

7 Nos. 63 Amp triple pole Moulded Case circuit breaker(Ics value 25 KA) with built in thermal based release unitwith adjustable setting.

- 3 Nos. 40 Amp triple pole Miniature circuit breaker (Icsvalue 10 KA).

- 1 No. 32 Amp double pole Miniature circuit breaker (Icsvalue 10 KA).

Set 1 195,700.00 - 195,700.00

2 NS

- 1 No. 125 Amp four pole Moulded Case Circuit Breaker (Icsvalue 25 KA) with built in thermal based release unit withadjustable setting .

INCOMER

OUTGOING

Note:

Sub Distribution Board - Auditorium

All breakers breaking capacities shall be ICU=ICS

Supply, Installation, Testing & Commissioning , cubicle type bodymade out of 2mm thick CRCA sheet,totally enclosed, IP 42,floor/wall mounted with channel base frame, dust and verminproof, indoor, compartmentalised, suitable for operation on 3phase and neutral, 415 V, 50Hz AC system with extensible busbarson both sides, making interlocking arrangement betweenincomers & buscoupler breakers, including control wiring with 2.5sq mm size wires/cable, interconnection, duly powder coatedpainting etc. including supply & installation of followingswitchgears,metering instruments and accessories as perspecifications.

3

Page 57: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

UNIT

DETAILED ESTIMATENAME OF WORK : FACULITY OF ARCHITECTURE & CANTEEN BUILDING AT NIT RAIPUR

SL.No. CPWD CODE NO. SCHD. RATE NON

SCHD.RATEQTYDESCRIPTION OF ITEM SCHD. AMOUNT NON SCHD. AMOUNT

- 150Amp 4 Pole busbars of high conductivity electrolyticquality copper alloy.

- 1 No. digital multifunction meter (Ammeter + Voltmeter) for3 phase, 4 wire operation as per specification.

- 1 Set of RYB phase indicating lamps controlled by 2 ampMCB.

- 3 Nos. 63 Amp triple pole Moulded Case circuit breaker(Ics value 25 KA) with built in thermal based release unitwith adjustable setting.

- 3 Nos. 40 Amp triple pole Miniature circuit breaker (Icsvalue 10 KA).

Set 1 116,700.00 - 116,700.00

3 NS

OUTGOING

Note:

All breakers breaking capacities shall be ICU=ICS

BUSBARS

INSTRUMENTS

Sub Distribution Board - CanteenSupply, Installation, Testing & Commissioning , cubicle type bodymade out of 2mm thick CRCA sheet,totally enclosed, IP 42,floor/wall mounted with channel base frame, dust and verminproof, indoor, compartmentalised, suitable for operation on 3phase and neutral, 415 V, 50Hz AC system with extensible busbarson both sides, making interlocking arrangement betweenincomers & buscoupler breakers, including control wiring with 2.5sq mm size wires/cable, interconnection, duly powder coatedpainting etc. including supply & installation of followingswitchgears,metering instruments and accessories as perspecifications.

4

Page 58: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

UNIT

DETAILED ESTIMATENAME OF WORK : FACULITY OF ARCHITECTURE & CANTEEN BUILDING AT NIT RAIPUR

SL.No. CPWD CODE NO. SCHD. RATE NON

SCHD.RATEQTYDESCRIPTION OF ITEM SCHD. AMOUNT NON SCHD. AMOUNT

- 1 No. 125 Amp four pole Moulded Case Circuit Breaker (Icsvalue 25 KA) with built in thermal based release unit withadjustable setting .

- 150Amp 4 Pole busbars of high conductivity electrolyticquality copper alloy.

- 1 No. digital multifunction meter (Ammeter + Voltmeter) for3 phase, 4 wire operation as per specification.

- 1 Set of RYB phase indicating lamps controlled by 2 ampMCB.

- 3 Nos. 63 Amp triple pole Moulded Case circuit breaker(Ics value 25 KA) with built in thermal based release unitwith adjustable setting.

- 2 Nos. 40 Amp triple pole Miniature circuit breaker (Icsvalue 10 KA).

Set 1 115,600.00 - 115,600.00

4 NS

Set 1 125,000.00 - 125,000.00

- 553,000.00 - 553,000.00

Supply, Installation, Testing & Commissioning , of wall mounted with6 Scene, 3 phase , 415 V, 50Hz AC system dimmer panel, includingsupply & installation of switchgears, instruments and controlingsoftware with internal wiring as per requirement.

Note:

INCOMER

BUSBARS

Cost After IndexTOTAL

INSTRUMENTS

OUTGOING

All breakers breaking capacities shall be ICU=ICS

5

Page 59: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

UNIT

DETAILED ESTIMATENAME OF WORK : FACULITY OF ARCHITECTURE & CANTEEN BUILDING AT NIT RAIPUR

SL.No. CPWD CODE NO. SCHD. RATE NON

SCHD.RATEQTYDESCRIPTION OF ITEM SCHD. AMOUNT NON SCHD. AMOUNT

B DISTRIBUTION BOARDS,MCBs & MCCBs

5 2.41 PWSPMCBDB

2.41.5 No. 1 3,659.00 3,659.00

6 NS

No. 4 4,448.00 - 17,792.00

No. 6 5,013.00 - 30,078.00

No. 2 5,928.00 - 11,856.00

7 2.52 MCBC

2.52.1 No. 314 94.00 29,516.00

8 2.53 MCBBPNo. 14 2.00 28.00

Supply and fixing 6 amps to 32 amps rating, 240volts,'c' series, MCBsuitable for lighting and other load of following pole in existing MCBDB complete with testing commissioning etc. as required.

Supply and fixing following way, single pole and neutral, prewirred,sheet steel,MCB distribution board,240 volt, on surface/resses,complete with loose wire box ,double door, terminalblock,duly prewired with suitable size FRLS PVC insulated copperconductor upto terminal block, tinned copper busbar, din bar,detachable gland plate, interconnectios, phosphatized andpowder painted including earthing etc. as required.(but withoutMCB/RCCB/ISOLATOR)

6+2way (8+ 6+18) , double door

12+2way (8+ 6+36) , double door

8+2way (8+ 6+24) , double door

Supply and fixing following way, three pole and neutral, prewirred,sheet steel,MCB distribution board,415 volt, on surface/resses,complete with loose wire box ,terminal block,duly prewiredwith suitable size FRLS PVC insulated copper conductor uptoterminal block, tinned copper busbar, din bar, detachable glandplate, interconnectios, phosphatized and powder paintedincluding earthing etc. as required.(but withoutMCB/RCCB/ISOLATOR)

2+ 8 way, double door

Single Pole

Supply and fixing Single pole blanking plate in existing MCB DBcomplete as required.

6

Page 60: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

UNIT

DETAILED ESTIMATENAME OF WORK : FACULITY OF ARCHITECTURE & CANTEEN BUILDING AT NIT RAIPUR

SL.No. CPWD CODE NO. SCHD. RATE NON

SCHD.RATEQTYDESCRIPTION OF ITEM SCHD. AMOUNT NON SCHD. AMOUNT

9 2.55 MCBTPIS

2.54.1 No. 5 345.00 1,725.00

2.54.2 No. 7 362.00 2,534.00

10

2.56 RCCBSPN

2.56.3 No. 3 1,164.00 3,492.00

11 NS

No. 15 2,191.00 - 32,865.00

No. 18 2,568.00 - 46,224.00

40,954.0 138,815.0 49,554.34 138,815.00

TOTAL

63 amps

Supply and fixing following rating, double pole(phase and neutral) ,240 volts RCCB UPTO 30mA sensitivity in existing MCB DB completewith connections testing and commissioning etc. as required.

Cost After Index

Supply and fixing following rating, double pole(phase and neutral) ,240 volts RCCB UPTO 300mA sensitivity in existing MCB DB complete with connections testing and commissioning etc. as required.

63 amps

63 amps

40 amps

40 amps

Supply and fixing following rating, four pole , 415volts, isolator inexisting MCB DB complete with connections testing andcommissioning etc. as required.

7

Page 61: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

UNIT

DETAILED ESTIMATENAME OF WORK : FACULITY OF ARCHITECTURE & CANTEEN BUILDING AT NIT RAIPUR

SL.No. CPWD CODE NO. SCHD. RATE NON

SCHD.RATEQTYDESCRIPTION OF ITEM SCHD. AMOUNT NON SCHD. AMOUNT

C

12 NS

Mtr 150 747.00 - 112,050.00

Mtr 140 415.00 - 58,100.00

Mtr 50 165.00 8,250.00

13

1.11 MVCBSUR25 Mtr 120 31.00 3,720.00

1.12 MVCBSUR120 Mtr 100 59.00 5,900.00

14

1.2 MVCBGR120

Mtr 70 91.00 6,370.00

15

1.3 MVCBGR400

Mtr 70 59.00 4,130.00

161.8 MVCBPIP400

Mtr 50 26.00 1,300.00

Laying and fixing of following sizes of one number PVC insulatedand PVC sheathed/XLPE Power cable of 1.1kv grade on surfaceor existing cable tray etc. as required.

Laying of one number PVC insulated & PVC sheathed power cableof 1.1kv grade of size exceeding 25sqmm but not exceeding120sq.mm direct in ground including excavation, sand cushioning,protective covering & refilling the trench etc. as required.

Laying of one number PVC insulated & PVC sheathed power cableof 1.1kv grade of size exceeding 25sqmm but not exceeding400sq.mm in the existing RCC Hume/ Stoneware/ GI / HDP pipe asrequired.

3.5 core, 70 Sq.mm.

Size exceeding 25 Sq.mm. but not exceeding 120 Sq.mm

MAIN & SUB MAIN CABLES

3.5 core, 150 Sq.mm.

Supply of following size of 1.1kv grade multicore aluminiumconductor XLPE insulated and PVC sheathed armoured cable asper IS : 7098:1988 with upto date amendments.

Size not exceeding 25 Sq.mm.

4 core, 16Sq.mm.

Laying of one number PVC insulated & PVC sheathed power cableof 1.1kv grade of size exceeding 120sqmm but not exceeding400sq.mm direct in ground including excavation, sand cushioning,protective covering & refilling the trench etc. as required.

8

Page 62: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

UNIT

DETAILED ESTIMATENAME OF WORK : FACULITY OF ARCHITECTURE & CANTEEN BUILDING AT NIT RAIPUR

SL.No. CPWD CODE NO. SCHD. RATE NON

SCHD.RATEQTYDESCRIPTION OF ITEM SCHD. AMOUNT NON SCHD. AMOUNT

17 NS

Mtr 60 463.00 - 27,780.00

Mtr 20 238.00 - 4,760.00

18 NS

Mtr 60 22.00 - 1,320.00

Mtr 20 17.00 - 340.00

19 4.1 MVET

4.1.26 Sets 4 278.00 1,112.00

4.1.23 Sets 4 168.00 672.00

4.1.33 Sets 2 196.00 392.00

20 NS

RM 50 848.00 - 42,400.00

23,596.0 255,000.0 28,551.16 255,000.00 Cost After Index

Fabricating and installing following size of galvanised ironperforated cable trays including horizontal and verticalbends,reducers,tees,cross members and other accessories asrequired and duly suspended from the ceiling with MS suspendersand including painting with powder coating etc as required.

TOTAL

Supply HDPE pipe for electrical and communication installationwith normal duty resistance to impact, Resistance to bending -pliable with bending radius of 2 meter,non metallic,resistance tochemical attack- without protection,protection against ingress ofsolid object and resistance against corrosion-withoutprotection,resistance to flame propogation with accessories asrequired.

Supply and making end termination with brass compression glandand aluminium lugs for XLPE insulated and PVC sheathedaluminium conductor cable of 1.1kv grade of the following sizes asrequired.

50x150 mm width x 50mm depth x 1.6 mm thickness.

100 mm inner dia

Laying of HDPE pipe for electrical and communication installationwith accessories as required including excavation,back filling andremoving the surplus earth complete as required

100 mm inner dia

3.5 core, 150 Sq.mm. AL Cable

3.5 core, 70 Sq.mm. AL Cable

4 core, 16 Sq.mm. AL Cable

150 mm inner dia

150 mm inner dia

Cable Tray

9

Page 63: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

UNIT

DETAILED ESTIMATENAME OF WORK : FACULITY OF ARCHITECTURE & CANTEEN BUILDING AT NIT RAIPUR

SL.No. CPWD CODE NO. SCHD. RATE NON

SCHD.RATEQTYDESCRIPTION OF ITEM SCHD. AMOUNT NON SCHD. AMOUNT

D

21 1.10 WGPVCMOD

1.10.3 No. 250 426.00 106,500.00

22

1.12 WGPVCPP2

RM 14750 97.00 1,430,750.00

23

1.14 WGPVCSB

1.14.2 RM 5500 81.00 445,500.00

1.14.3 RM 1750 97.00 169,750.00

1.14.4 RM 50 127.00 6,350.00

1.14.11 RM 260 294.00 76,440.00

1.14.12 RM 330 487.00 160,710.00

Wiring for light plug with 2 x 4 sqmm FRLS PVC insulated copperconductor, single core cable in surface / recessed PVC conduitwiring along with 1 No. 4 sqmm FR PVC insulated copperconductor single core cable etc as required.

4 x 16 + 2 X 16 sq. mm earth wire

4 x 10 + 2 X 10 sq. mm earth wire

POINT WIRING

Wiring for circuit/sub main wiring with the following sizes of FRLSPVC insulated copper conductor single core cable in surface /recessed PVC conduit alongwith accessories as required

2 x 2.5 + 1 X 2.5 sq. mm earth wire

Wiring for light point / fan point / exhaust fan point / call bell pointwith 1.5 sqmm FRLS PVC insulated, copper conductor cable insurface / recessed PVC conduit,with modular type switch, modularplate, suitable size GI box along and earthing the point with 1.5sqmm FR PVC insulated copper conductor single core cable etc asrequired.

Group C

2 x 6 + 1 X 6 sq. mm earth wire

WIRING & ACCESSORIES

2 x 4 + 1X 4 sq. mm earth wire

10

Page 64: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

UNIT

DETAILED ESTIMATENAME OF WORK : FACULITY OF ARCHITECTURE & CANTEEN BUILDING AT NIT RAIPUR

SL.No. CPWD CODE NO. SCHD. RATE NON

SCHD.RATEQTYDESCRIPTION OF ITEM SCHD. AMOUNT NON SCHD. AMOUNT

24 1.21 PVCCON

1.21.1 RM 1050 41.00 43,050.00

1.21.2 RM 900 47.00 42,300.00

1.21.3 RM 480 56.00 26,880.00

25 1.24 MODSWEB

1.24.1 No 497 46.00 22,862.00

1.24.3 No 115 67.00 7,705.00

1.24.4 No 230 64.00 14,720.00

1.24.5 No 110 101.00 11,110.00

1.24.6 No 36 27.00 972.00

1.24.7 No. 4 27.00 108.00

1.25 MODFREB No 121 247.00 29,887.00

261.28 MODCP

1.28.1 No 117 51.00 5,967.00

1.28.2 No 69 71.00 4,899.00

1.28.6 No 14 113.00 1,582.00

Ceiling fan regulator

Telephone Socket Outlet

TV antenna socket outlet

Four module plate

5/6 amps 3 pin socket

Supply and fixing of of following sizes of modular base and coverplates of approved colour with Metal boxes complete as required

6/16 amps 6 pin socket

Six/ Eight module plate

One to three module plate

Supply and fixing of following sizes of modular type switches /sockets outlets on the existing modular plate and switch boxincluding connection but excluding modular plate etc.ofapproved colour as required

32mm

Switch 5/ 6 amps one way

Switch 15/16 amps one way

25mm

Supplying and fixing of following sizes of PVC conduit along theaccessories in surface / recess including surface conduit or cuttingthe wall and making good the same in case of recessed conduit asrequired for FAS, Telephone,Data Networking & PA system.

20mm

11

Page 65: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

UNIT

DETAILED ESTIMATENAME OF WORK : FACULITY OF ARCHITECTURE & CANTEEN BUILDING AT NIT RAIPUR

SL.No. CPWD CODE NO. SCHD. RATE NON

SCHD.RATEQTYDESCRIPTION OF ITEM SCHD. AMOUNT NON SCHD. AMOUNT

27 1.26 MODBPEB

No 60 20.00 1,200.00

28 1.15 RW

1.15.3 No. 140 401.00 56,140.00

29 1.17 WGEC

1.17.2 mtr 1300 25.00 32,500.00

1.17.12 mtr 400 43.00 17,200.00

1.17.21 mtr 350 58.00 20,300.00

30 1.18 TLWGEC

1.18.3 mtr 1050 21.00 22,050.00

31 1.19 TVWGEC

mtr

100 23.00 2,300.00

32 2.62 MCBDPSOC20

No

14 520.00 7,280.00

2,767,012.0 0.0 3,348,084.52 -

Supplying and fixing 20amos, 240volts, SPN industrial type socketoutlet, with 2 pole and earth metak enclosed plug top along with20 amps 'C' series, 'SP MCB' in sheet steel enclosure, on surface or inrecess with chained metal cover for the socket outlet andcomplete with connections,testing and commissioning etc asrequired.

Supplying and drawing following pair, 0.5sqmm FR PVC insulatedcopper conductor, unarmoured telephone cable in the existingsurface/recessed steel/PVC conduit as required

TOTAL

3 x 4 sq. mm

Supply and fixing blanking modular plate on existing modular plateswitch box including connection but excluding modular plate etc.as required.

3 x 2.5 sq.mm

Supplying and drawing Coaxial TV cable RG-6 grade, 0.7mm solidcopper conductor PE insulated,shielded with fine tinned copperbraid and protected with PVC sheath in the existingsurface/recessed steel/PVC conduit as required

Group C

Rewiring for light point / fan point / exhaust fan point / call bellpoint with 2.5 sqmm FRLS PVC insulated, copper conductor cableand earthing the point with 2.5 sqmm FR PVC insulated copperconductor single core cable in EXISTING surface / recessed PVC/steel conduit including dismantling as required

Supplying and drawing following sizes of FR PVC insulated copperconductor, single core cable in the existing surface/ recessed steel/PVC conduit as required.2 x 1.5 sq,mm for FAS

4 pair

Cost After Index

12

Page 66: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

UNIT

DETAILED ESTIMATENAME OF WORK : FACULITY OF ARCHITECTURE & CANTEEN BUILDING AT NIT RAIPUR

SL.No. CPWD CODE NO. SCHD. RATE NON

SCHD.RATEQTYDESCRIPTION OF ITEM SCHD. AMOUNT NON SCHD. AMOUNT

E33 NS

RM 60 1,520.00 - 91,200.00

RM 80 652.00 - 52,160.00

34 NS

No 8 6,544.00 - 52,352.00

35 NS

No 24 1,793.00 - 43,032.00

0.0 238,744.0 - 238,744.00

GI RACEWAY & JUNCTION BOXES (IP 44)

300 mm wide x 38 mm deep raceway (3 compartment)

Providing and fixing 400 x 400 x 60 mm deep GI (hot dipgalvanized) raceways made out of 1.6 mm thick sheet steeljunction Box as per specification.

Supply and installing following size of under floor GI (hot dipgalvanized) raceways made out of 1.6 mm thick sheet steel,withinternal compartments complete with jointing sleeves and otheraccessories under floor installation including cutting and chasingthe floor, making good the same ,placing in position and cleaningfrom inside complete of following sizes etc. as required.

100 mm wide x 38 mm deep raceway (3 compartment)

Providing and fixing 150 x 150 x 60 mm deep GI (hot dipgalvanized) raceways made out of 1.6 mm thick sheet steeljunction box as per specification.

TOTAL Cost After Index

13

Page 67: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

UNIT

DETAILED ESTIMATENAME OF WORK : FACULITY OF ARCHITECTURE & CANTEEN BUILDING AT NIT RAIPUR

SL.No. CPWD CODE NO. SCHD. RATE NON

SCHD.RATEQTYDESCRIPTION OF ITEM SCHD. AMOUNT NON SCHD. AMOUNT

F36 NS

Type 1:

No. 160 3,610.00 - 577,600.00

37 NS Type 2:

No. 226 2,795.00 - 631,670.00

38 NS Type 3:

46 2,387.00 - 109,802.00

39 NS Type 4:

No 28 1,013.00 - 28,364.00

40 NS Type 5

No. 10 12,156.00 - 121,560.00

41 NS Type 6

No. 10 10,689.00 - 106,890.00

42 NS Type 7

No. 30 5,344.00 - 160,320.00

Recess mounted downlighter, with decorative PBT housing. Option with glass reflector (chrome plate) complete with 2 x 42W PL lamp and both housing and attachment of glass Philips Cat No. FBH 225/242 HF ALR ar equivalent.

Surface mounted mirror optic lumianire suitable for linear fluoresent2X28 W TL5 lamp with standard darklite optics. PHILIPS make, CatNo: TCS 350/228 MI HF

Surface mounted downlighter with 1X18W PL-C lamp completewith vertical lamp and specular finished patterned reflector. PHILIPS make, Cat No: FCS 100/118.

Track mounted high efficiency projector downlighter, suitable for CDM lamps 1 x CDMTC 70W. Philips Cat No. MRS 502 1 x CDM-TC 70W EB 24 3CWH

LIGHTING FIXTURES SUPPLY & INSTALLATIONSupply, receiving, storing, handling of the following light fixturescomplete with all fixing accessories, control gear as requiredINCLUDING LAMPS at site. of following type. Fitting shall be of catno. and make as specified or similar.

Surface mounted mirror optic lumianire suitable for linear fluoresent1X28 W TL5 lamp with standard darklite optics. PHILIPS make, CatNo: TCS 350/128 MI HF

Surface mounted high efficiency projector downlighter, suitable for CDM lamps 1 x CDMTC 70W. Philips Cat No. MCS 502 1 x CDM-TC 70W EB 24 3CWH

Reccessed mounted lumianire with mirror optics designed formetric false ceiling type suitable for 2X28 W TL5 lamp. PHILIPS make, Cat No: TBS 008/228 C5 HF-P

14

Page 68: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

UNIT

DETAILED ESTIMATENAME OF WORK : FACULITY OF ARCHITECTURE & CANTEEN BUILDING AT NIT RAIPUR

SL.No. CPWD CODE NO. SCHD. RATE NON

SCHD.RATEQTYDESCRIPTION OF ITEM SCHD. AMOUNT NON SCHD. AMOUNT

43 NS

No 155 1,941.00 - 300,855.00

44 NSNo 24 1,164.00 - 27,936.00

45 1.41 ITCFFSUR

No 220 43.00 9,460.00

46

205 105.00 21,525.00

47 1.44 ITCCF

No. 155 86.00 13,330.00

48 1.52 ITCEF450

No. 24 434.00 10,416.00

54,731.0 2,064,997.0 66,224.51 2,064,997.00

Installation, testing and commissioning of 1200mm ceiling fan,including connection with 1.5 sq.mm FRLS PVC insulated copperconductor three core cable etc. as required.

1200mm size ceiling fan including suitable size hanging rod (max.1.0 mtr) with all acesseries GEC/ CROMPTON/ HAVELS/ USHA/KHETAN MAKE

Installation, testing and commissioning of prewired flourescentfitting / compact flourescent fittings of all types complete with allaccessories and tubes etc. in false ceiling including hangingingarrangement and connection with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.

Installation, testing and commissioning of prewired flourescentfitting/ compact flourescent fittings of all types complete with allaccessories and tubes etc. directly on ceiling/wall/ Surfaceincluding connection with 1.5 sq.mm FRLS PVC insulated copperconductor single core cable etc. as required.

TOTAL

300mm size Exhaust fan including with all acesseries GEC/ CROMPTON/ HAVELS/ USHA /KHETAN MAKE

Installation of exhaust fan fan upto 450mm sweep in the existingopening, including making the hole to suit the size of the abovefan, making good the damage, connection, testing,commissioning etc as required.

Cost After Index

LIGHTING FIXTURES (ITC)

15

Page 69: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

UNIT

DETAILED ESTIMATENAME OF WORK : FACULITY OF ARCHITECTURE & CANTEEN BUILDING AT NIT RAIPUR

SL.No. CPWD CODE NO. SCHD. RATE NON

SCHD.RATEQTYDESCRIPTION OF ITEM SCHD. AMOUNT NON SCHD. AMOUNT

G49 3.2

EARPIPCHAR

Set 2 1,771.00 3,542.00

50 3.11 EARGI25X5

Mtr 50 45.00 2,250.00

51 3.14 EARGISTPIP Mtr 50 218.00 10,900.00

16,692.0 0.0 20,197.32 -

TOTAL

Earthing with G.I. pipe 4.5 mtr long, 40mm dia includingaccessories, and providing masonary enclosure with cover platehaving locking arrangement and watering pipe etc. with charcoaland salt as required.

Supplying and laying of 25mm X 5mm G.I. strip at 0.5 metre belowground as strip earth electrode, including soldering etc as required.

Supplying and laying of 25mm X 5mm G.I. strip in 40mm dia G.I.pipe from earth electrode, as required.

EARTHING

Cost After Index

16

Page 70: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

UNIT

DETAILED ESTIMATENAME OF WORK : FACULITY OF ARCHITECTURE & CANTEEN BUILDING AT NIT RAIPUR

SL.No. CPWD CODE NO. SCHD. RATE NON

SCHD.RATEQTYDESCRIPTION OF ITEM SCHD. AMOUNT NON SCHD. AMOUNT

52 NS

- 1 No. 63Amp four pole Moulded Case Circuit Breaker (Icsvalue 25 KA).

- 100Amp TPN busbars of high conductivity electrolyticquality aluminium alloy.

- 1 No. 96x96 analogue type Voltmeter suitable range for 3phase, 4 wire operation with LED display and selectorswitch withcontrolled by 3 sets of 2Amp MCB .

- 1 No.96x96 analogue typeAmmeter of suitable range ( 0to 80Amp), for 3 phase 4 wire operation with LED displayand selector switch

- 3 Nos of LED type phase indicating lamps (RYB) withcontrolled by 2Amp MCB .

- 1 No.6A, 2 pole Auto/OFF/Manual (2 way with OFF) selector switch.

- 2 Nos. of push button actuator

FEEDER PILLAR-1

BUSBARS

EXTERNAL LIGHTING

Supply, installation, testing and commissioning of cubicle typetotally enclosed free standing, dust free, damp and vermin proofand water proof outdoor (IP 65) Feeder pillar fabricated out of2mm thick CRCA sheet duly powder coated and including supply& fixing the following items and interconnections, wiring withsuitable size wires/cables and including all civil works likeexcavation, PCC, brick work pedestal, plastering, refilling etc. andas per specifications as required.

INCOMER

INSTRUMENTS & ACCESSORIES

17

Page 71: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

UNIT

DETAILED ESTIMATENAME OF WORK : FACULITY OF ARCHITECTURE & CANTEEN BUILDING AT NIT RAIPUR

SL.No. CPWD CODE NO. SCHD. RATE NON

SCHD.RATEQTYDESCRIPTION OF ITEM SCHD. AMOUNT NON SCHD. AMOUNT

- 1 set of 40 Amps 4 pole MCB with 40 Amps four polecontactor 0-24 hours timer auto / manual by pass selectorswitches including 18 Nos. 16/10 Amps SP MCB with 3 Nos.40 Amps DP RCCB’s of 100 mA leakage current withseparate neutral link of each phase.

Set 1 95,000.0 - 95,000.00

53 NS Type 4 a

No. 16 15,097.0 - 241,552.00

54 NS

No. 16 2,575.0 - 41,200.00

55 NS Type 5

No. 15 7,469.0 - 112,035.00

0.0 489,787.0 - 489,787.00

TOTAL

Supply, Installation, Testing & commissioning of 2 X 36 watt TLDfluorescent street light luminaire with sheet aluminium housing andUV stablized acrylic cover, Complete with Mounting bracket MakePhilips TRC 33/236 HPF. or Equivalent

Type 4 b

Supply, Installation, Testing & commissioning of 18W PL Bollarddecorative light fixture IP 65 with color as per Architect Make Philips HCS 370 1 XPL-L 18

OUTGOING

Supply, Installation, Testing & commissioning of standard 7 metre(above ground) high,single arm complete with mounting bracketmade out of GI tubular pole,primered and PU painted factoryfinish. The pipe should be of 114 mm dia with base plate dimension300x300x20 mm. The pipe should be medium grade and shall havecrossection thickness of 4.2 mm with tolerance +/- 5%. The cementconcreate column height 750mm above ground and 450mm diashall be provided along with with flush door at the bottom withproper strengthening to the cutout of the door opening including ajunction/ looping box with Heavy duty 3 phase, 32 Amp connectorwith 32A DP MCB be fixed including necessary cement concretefoundation 1:2:4 exvaution and refilling complete as required .

Cost After Index

18

Page 72: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

FIRE FIGHTING & FIRE ALARM WORKS

( PAGE : 1 TO 8 )

Page 73: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sr.No DESCRIPTION DSR AMOUNT (Rs) NON DSR AMOUNT (Rs)

FIRE FIGHTING WORKS

A FIRE PROTECTION SYSTEM 0.00 645250.00

B MCC-1 for fire fighting equipments for terrace pump 0.00 100000.00

FIRE ALARM WORKS

C INTELLIGENT ANALOGUE ADDRESSABLE FIRE DETECTIONAND ALARM SYSTEM CONTROL PANELS, MODULES,SENSORS & ALARM INITIATING DEVICES

0.00 616600.00

TOTAL COST 0.00 1361850.00

FIRE FIGHTING & FIRE ALARM WORKS

SUMMARY OF COST

1

Page 74: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No DSR Item Description Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

A.

1 NS Supply, installation, testing and commissioning of multistage Terrace pump(pressurisation pump) comprising of the following:

a. Horizontal Multistage centrifugal pump, suitable for operation on 415 volts ± 6%, 3phase, 50 HZ AC supply. The installation shall be complete with Flexible coupling andcoupling guard, complete as required.

The pump casing shall be CI, shaft shall be SS & impeller / shaft sleeve / casing wearingring shall be bronze. The pump shall be provided with mechanical seal The system shallbe complete with necessary pressure gauge gun metal shut off cock on delivery side.(The pump should meet the condition and shall have approval of Local fire Authority).

b. Squirrel cage induction motor TEFC type for operation on 415 V, 3 phase 50 Hz ACsupply for the above pump with a synchronous speed of 2900 R.P.M. with flexiblecoupling and coupling guard etc. as required.

c. Common base plate for (a) and (b) from M.S. channel as required size.

d. Suitable cement concrete foundation with plaster, (design and drawing to beprovided by the Contractor while the foundation will be done by others) complete withAntivibration arrangement of cushy foot mounting.

For Pump defined above & of duty as follows :

Flow : 450 LPMHead : 35 mts Set 1 60000 60000

2 NS Providing, fixing, testing & commissioning of MS air cushion tank on top of each riserfabricated from 12mm thick MS plate, 200 mm in diameter and 1.2 m in height withdished ends fabricated from 8mm thick MS plate with Air release valve with stop cock,flanged inlet connection and drain arrangement with 25mm dia valve, pressure gaugewith gun metal stop cock complete with all accessories as required and conforming to IS4736-1968. (The cushion tank should be suitable for rated working pressure.

Set 1 15000 15000

FIRE FIGHTING WORKS

FIRE PROTECTION SYSTEM

Fire Equipment

2

Page 75: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No DSR Item Description Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

3 NS Providing & fixing dial type (100 mm) pressure gauge with isolation ball valve suitable forworking pressure of 250 PSI. Cost shall be inclusive of providing any short pieces, nipples,elbows etc as required. Nos 1 1500 1500

Note: Contractor shall include in his rates for providing pressure switches, wiring, cabling frompressure switch to panel etc. complete as required to operate the systemautomatic/manual. Pump shall be protected against running dry.

4 NS

Providing, laying, jointing, testing and commissioning of following sizes of pipesconforming to IS-1239 with all accessories like all fittings (standard MS fitting with weldedjoint shall be used on the pipes) including tees, elbows, reducers, union, flanges, rubbergaskets, GI nuts bolts, washer including supporting/fixing the pipe on floor / wall /ceilingwith clamps, hangers (using anchor fastners) as per specification. suitable protection tosafe gard corrosion shall be provided wherever the pipes are crossing the walls/floorsand sealing the oppenings as per Project Manager’s / Consultants requirementsincluding cutting holes and chases in brick, R.C.C work and making good the same tooriginal conditions complete in all respects. All hangers, clamps, brackets etc. shall be ofgalvanized iron unless specified otherwire and then supply of the same shall also beincluded for rates under this head.

Welding of any kind on the galvanized support / hanger shall not be permitted includingsynthetic enamel paint of approved shade over a coat of zinc primer.

For wet riser System - MS `C' Heavy class pipe

25 mm dia RM 15 350 525080 mm dia RM 10 1000 10000100 mm dia RM 150 1400 210000150 mm dia RM 10 1800 18000

5 NS Providing two coats of synthetic enamel paint of approved shade over a coat of primer.Prior to application of primer the surface should be cleaned for any dirt, rusts, roughsubstance etc. Including painting of legends both direction arrow as per the approvalof the Project Manager.

25 mm dia RM 15 10 15080 mm dia RM 10 25 250100 mm dia RM 150 25 3750150 mm dia RM 10 30 300

6 NS Providing and fixing forged brass ball valve with forged brass ball suitable for testpressure of not less than PN16 of the following size :

(Cost shall be inclusive of providing necessary union / flange connection etc).

Hydrants, Piping & Accessories

3

Page 76: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No DSR Item Description Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

25 mm dia No. 5 850 4250

7 NS Providing & fixing of butterfly valve (suitable for test pressure of PN16) with flanges, nutbolts, gaskets and necessary pad locking arrangement complete required.

100 mm dia No. 4 5500 22000150 mm dia No. 1 9000 9000

8 NS Providing and fixing of CI wafer type dual plate check valve (suitable for test pressure ofPN16) with flanges, Nut, bolts & washers, painting etc. complete as required.

100 mm dia No. 1 5000 5000

9 NS Providing & fixing gun metal fire hydrant single landing valve with 80 mm NB flangedinlet, brass spindle controlled 63 mm dia female instantaneous outlet type. G.M.coupling, blank cap, chain, twist release type lug & all accessories Conforming toIS:5290. Including fixing with anchor fastner and flanged tapping from wet riser andproviding pressure gauge with gun metal ball valve complete as required.

No. 4 7500 30000

10 NS Providing & fixing swinging type First Aid hose reel in red colour drum with 36 mts longand 20 mm dia heavy duty rubber water hose, 20 mm dia ball valve stop cock ofsuitable rating, terminating with G.M coupling & nozzle of 6mm outlet with shut off valveconfirming to IS 8090 - 1976 complete with MS socket for tap-off, drum and brackets(including painting) for fixing on wall with anchor fastner, bolts & nuts conforming toIS:884-1969 complete as required. No. 4 8000 32000

11 NS Providing & fixing controlled percolation fire hose pipe (as per IS:8423) of 63 mm dia and15 meter length rated for brust pressure of 35.7 Kg/sqcm. The hose shall be tested forflame resistance test in accordance to IS:8423. Hose shall be complete with ISI markedbrass male & female coupling (IS:903) bound & riveted to hose pipe with copper rivets &1.5 mm copper wire (Location : fire hydrant). Nos. 8 4500 36000

12 NS Providing and Fixing 63 mm dia instantaneous pattern branch short gunmetal pipe, 20mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe couplingcomplete as required. Nos. 4 1200 4800

13 NS Providing and fixing standard firemans axe with heavy rubber handle. Nos. 4 750 3000

4

Page 77: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No DSR Item Description Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

14 NS Providing & fixing indoor type hose lockable cabinet frames fabricated from 40 x 40 x 5angle iron sections and 16 gauge MS sheet with full front glass door and lockingarrangement, suitable to accommodate landing valves, 15 m long hoses, first-aid hosereel and branch pipe nozzle & fire mans’ axe. The cabinet frame shall be painted withone coat of primer and two or more coats of synthetic enamel paint of approved makeand shade of as required (Approx 2.1 m (high) x 0.9 m (wide) x 0.6 m (deep) ). The itemshall be complete of MS housing with front door.

(Cost shall be inclusive of providing break glass box containing key for the cabinet alongwith hammer). Nos. 4 20000 80000

Portable Chemical Fire Extinguishers

Supply, installation, testing and commissioning of following types of extinguisher withprovision of wall bracket (fixed with anchor fastner).

15 NS ISI marked (IS:940) portable chemical fire extinguisher, water (gas pressure) typecapacity 9 litres with gun metal cap and nozzle and complete in all respects includinginitial fill and wall suspension brackets Each 6 2000 12000

16 NS ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat baseincluding valve, discharge hose of not less than 10 mm dia, 1M long and complete in allrespects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rateof not more than 0.667 and wall suspension bracket. Each 6 6000 36000

17 NS ABC (Powder Type) Fire Extinguisher. In HP Mild Steel Cylinders ISI marked TAC approvedfitted with pressure indicating gauge, internal tube, squeeze lever type valve fullycharged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogencomplete in all respects including wall suspension bracket and confoming to IS:1349-1993

10 Kg Each 6 6500 39000

18 NS Supplying and installing at approved location approved make fire buckets of 20 gaugegalvanized steel sheet, standard 9 litre capacity and of round bottom shape, paintedwhite inside and red outside and black on the bottom, inscribed with letters “FIRE” inblack and gold. Cost shall be inclusive of providing MS stand duly painted over a coatof primer. (One stand shall be suitable for hanging 5 buckets).

No. 4 2000 8000

TOTAL 0.00 645250.00Cost After Index 0.00 645250.00

5

Page 78: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No DSR Item Description Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

B MCC-1 for fire fighting equipments for terrace pump

19 NS Incominga. 2 Nos. 63 amps TPN mechanical incoming MCCB complete with the following

i. 0-500 volts 96 x 96mm square voltmeter with selector switch shall be protected by 2amps TP MCB 1 Setii. 0-63 amps 96 x 96 mm square ammeter with 63/5 amps 15 VA CL:1 CT's and selectorswitch 1 Setiii. Phase indicating lamps shall be protected by 2 amps SP MCB1 Sets

Bus Bar

500 amps TPN aluminium bus bar with heat shrinkable insulation sleeves.

Outgoing:a. 1 Nos. Star Delta starters out going feeders Terrace pump motor. Auto / manualselector switch and indicating lamp with MCBs for `ON'/OFF`TRIP' status of motor.

d. Necessary cable alleys space for spare switches, internal wiring and copper earthingof all equipment shall also be included. All switch gears/control gears shall be motorduty rating.

Note:All MCCB's to be suitable for motor duty and shall be of 25 KA breaking capacity.

Set 1 100000 100000Provision shall be made for providing potential free contacts to all pumps starters forconnection to fire alarm system.

MCC-1 as described above

TOTAL 0.00 100000.00Cost After Index 0.00 100000.00

6

Page 79: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No DSR Item Description Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

C INTELLIGENT ANALOGUE ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM CONTROL PANELS, MODULES, SENSORS & ALARM INITIATING DEVICES

20 NS Supply, installation, testing and commissioning of following as per specifications :

Microprocessor based intelligent analogue addressable, modular, expandablenetworkable, 2 loop ( each loop consist of 125 detector & 125 devices )fire alarmcontrol panel with minimum 640 character LCD display, multiple access levels, eventhistory file in non-volatile memory (EEPROM). The panel shall have a built-in intergradedvoice command center with suitable rating amplifier for 30 speaker zones. The panelshall support programmable relay for controlling lifts, staircase pressurizations fans, liftshaft & lift lobby pressurization fans, toilets exhaust fans, ventilation fans at fire pumproom, monitoring of fire sprinkler and fire hydrant pump controlled by powerful Booleanlogic equation.

The panel shall have minimum five independent hazard release circuit built-in the panel.The panel shall have 240 volts AC power supply, automatic battery charger, 24 volts,sealed lead acid maintenance free batteries sufficient for 24 hours normal working andthen be capable of operating the system for 60 minutes during emergency condition.The panel shall be UL/EN listed. Tenderer to provide interfacing connectivity (BAC Netgateway) for building management sysem complete as per specification.

No. 1 350000 350000

21 NS Repeater panel with 640 character back lit LCD display with complete system functionkeys for programming and control like system reset, Alarm Acknowledge, Alarm Silence,Trouble Acknowledge etc. as per specification . No. 2 60000 120000

22 NS Fault isolator module for isolating shorted, dewired and loose circuits between twosuccessive fault with automatic resetting arrangement. No. 4 2500 10000

23 NS Intelligent Analogue addressable photoelectric smoke detector including mountingbase with LED etc. complete as per specification. No. 30 3500 105000

FIRE ALARM WORKS

7

Page 80: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No DSR Item Description Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

24 NS Intelligent analogue intelligent rate of rise cum fixed temperature thermistor type heatdetector with mounting base, LED, fixed temperature setting as per specification.

No. 3 3200 9600

25 NS Addressable manual call point as per specification No. 5 1000 5000

26 NS Sounder with signaling strobe light with 110 cd intensity as per specification No. 5 1000 5000

27 NS Round speaker ceiling / wall mounting arrangement (0-2 watts) with multiple tapingcomplete as per specification No. 15 800 12000

Total 0.00 616600.00Cost After Index 0.00 616600.00

8

Page 81: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

ACCOUSTICAL CEILING WORKS

( PAGE : 1 TO 8 )

Page 82: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sr.No Description DSR AMOUNT (Rs.) NON DSR AMOUNT (Rs.)

A Audi Wall Paneling 0.00 306620.74

B DADO Paneling 0.00 84079.84

C Audi Rare Wall Paneling 0.00 164374.00

D Audi Ceiling 0.00 230044.92

E Stage Ceiling 0.00 46552.69

F Stage Wall Paneling 0.00 286057.89

G Stage Flooring 0.00 228739.42

TOTAL COST 0.00 1346469.50

ACCOUSTICAL CEILING WORKS IN AUDITORIUM

SUMMARY OF COST

1

Page 83: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

A NS Audi Wall Paneling:Providing and fixing Anutone Smooth primer sound Absorbing onpanel of size 1200x600x25 mm ND4. Which will comprise of basepanel with humidity resistance of 95% RH, and thermalconductivity K=0.082 W/Mk with sag resistance with normal edgeprofile. Anutone Smooth sound Absorbing panel is to be installedon Anutone Strut framework and meet the stringent fire testrequired having Class ‘P’ rating for ignitability test as per BS 476part 5 and Class ‘1’ rating as per BS 476 part 7 for surface spreadof flame test. Class ‘P’ and Class ‘1’ are the highest rating. BS 476part 6 fire propagation index and flaming ISO 1182 and smokedensity as per ASTM E 662 besides base panel conforms to EN13168 2000 with complete framework of Anutone Strut as per theInstallation details given.

Anutone Smooth primer sound Absorbing panel of size1200x1600x25 mm ND4. is to be fixed on ASP Anutone Strutchannel of G I section of prime quality cold rolled steel as per IS513 hot dipped galvanized 120 gsm as per BS 2989 and zinccoating as per IS 277 on CC-50 main channel and FC-52 on floorand ceiling channel is to be fixed with plastic sleeves andwooden screws to form the proper framwork .The Anutone SynthAW 10x50 of density should be inserted in cavity of G I frameworkfor better insulation & comfort conditions. The channel will comeat every 600 centre to centre. Anutone Smooth primer is to befixed on channels with the help of steel screws at every 230 mmdistance interval and 10 mm away from the edges of panel forproper holding with the GI framework then finally Spun Cordfabric of approved colour should be pasted on the panel in line& level. As per the specification and direction of the Engineerincharge.

97 3161.04 306620.74

Total 0.00 306620.74Cost After Index 0.00 306620.74

DSR Amounrt

Non DSR AmounrtSl.No

ACCOUSTICAL CEILING WORKS IN AUDITORIUM

DescriptionDSR Item Unit Qty DSR Rate Non DSR Rate

2

Page 84: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

DSR Amounrt

Non DSR AmounrtSl.No DescriptionDSR Item Unit Qty DSR Rate Non DSR

Rate

B NS DADO Paneling:Providing and Fixing Anutone Sonator 8mm thick for LFAbsorption with Z-clip or head less nails depand upon theapplication with complete framework of Anutone SoundStrutalong with Synth AW 10X50 to be filled in cavity of GI frameworkfor Sound insulation and comfort condition as per drawing andInstallation details givenThe Anutone Sonator is to be fixed upto 1200mm height fromground level, on Anutone Strut ASP floor and ceiling channel &stud of G I section of prime quality cold rolled steel as per IS 513hot dipped galvanized 120 gsm as per BS 2989 and zinc coatingas per IS 277on CC-50 main channel and FC-52 on floor andceiling channel is to be fixed with plastic sleeves and woodenscrews to form the proper framwork .The extra channel must beused at openings and junctions as required. The Synth AW 10x50of surface density should be installed in cavity of GI frame betterinsulation & comfort conditions. The channel will come at every600 centre to centre. Sonator of 8mm thickness is to be installedwith 20x20 mm Teakwood section with Z-clip on the board intothe GI frame for proper holding and LF Absorption as shown indrawing As per the specification and direction of the Engineerincharge

29 2899.30 84079.84

Total 0.00 84079.84Cost After Index 0.00 84079.84

3

Page 85: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

DSR Amounrt

Non DSR AmounrtSl.No DescriptionDSR Item Unit Qty DSR Rate Non DSR

Rate

C NS Audi Rare Wall Paneling:Providing and fixing Anutone Smooth primer sound Absorbing on

panel of size 1200x600x25 mm ND4. Which will comprise of basepanel with humidity resistance of 95% RH, and thermalconductivity K=0.082 W/Mk with sag resistance with normal edgeprofile. Anutone Smooth sound Absorbing panel is to be installedon Anutone Strut framework and meet the stringent fire testrequired having Class ‘P’ rating for ignitability test as per BS 476part 5 and Class ‘1’ rating as per BS 476 part 7 for surface spreadof flame test. Class ‘P’ and Class ‘1’ are the highest rating. BS 476part 6 fire propagation index and flaming ISO 1182 and smokedensity as per ASTM E 662 besides base panel conforms to EN13168 2000 with complete framework of Anutone Strut as per theInstallation details given.

Anutone Smooth primer sound Absorbing panel of size1200x1600x25 mm ND4. is to be fixed on ASP Anutone Strutchannel of G I section of prime quality cold rolled steel as per IS513 hot dipped galvanized 120 gsm as per BS 2989 and zinccoating as per IS 277 on CC-50 main channel and FC-52 on floorand ceiling channel is to be fixed with plastic sleeves andwooden screws to form the proper framwork .The Synth AW 10x50of density should be inserted in cavity of G I framework for betterinsulation & comfort conditions. The channel will come at every600 centre to centre. Anutone Smooth primer is to be fixed onchannels with the help of steel screws at every 230 mm distanceinterval and 10 mm away from the edges of panel for properholding with the GI framework then finally Spun Cord fabric ofapproved colour should be pasted on the panel in line & level.As per the specification and direction of the Engineer incharge.

52 3161.04 164374.00

Total 0.00 164374.00Cost After Index 0.00 164374.00

4

Page 86: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

DSR Amounrt

Non DSR AmounrtSl.No DescriptionDSR Item Unit Qty DSR Rate Non DSR

Rate

D NS Audi Ceiling:Anutone Subtex Texture Square edge 15mm for Ceiling of size595x595x15 mm is to be installed on framework of AnutoneSkelet. Which will comprise of NRC 0.94 base panel with humidityresistance of 90% RH as per ISO-4611,ASTM C-165 ,ASTM C-303 ,ASTM C-1104 and light reflectance upto 85% with Leed pointsGreen Performance certified, and Thermal conductivity K=0.082W/Mk with sag resistance with normal edge profile. AnutoneSubtex Texture 15mm for Ceiling tile meet the stringent fire testrequired having Class ‘A’ rating for Flame Ignitability test as perASTM-E-84, with complete framework of Anutone Skelet as perInstallation details givenAnutone Subtex Texture Square edge 15mm for Ceiling Tile is tobe layed on frame work of ASP Anutone Skelet accessories pre-coated GI angle size 24x24x0.4 mm thick fixed to the brick wall /partition at the perimeter of ceiling with Nylon Sleeves and APSwafer head drywall screws, Then suspended main GI ‘T’ section(bottom precoated-White) with polyester coating of 25 micronsdry film thickness. Main T-section size 24x38x0.3 mm thick and3600 mm long from soffit in one direction with the help of ASPmetal rawl plug, cleat, leveler, perimeter & wall spring clip & G IRod 4 mm diameter with galvanized spring steel level clip 1200mm centres from soffit. GI cross T section (bottom precoated-White) size 24x25x0.3 mmand 1200mm & 600mm long is insert fixed into the slots providedas interlock in main ‘T’ at 600 mm centres to form 600x600mmgrid size for a tile size of 595x595 mm. All accessories such as ASPAnutone Skelet accessories cleat, suspenders, levelers, clips etc,shall be supplied and installed in accordance with manufacturerrecommendation and ASTM C 636 as per Anutone Skeletaccessories from Selec portal. The ASP T-System shall satisfy a 1hour fire rating as per BS 476 Part 23. Anutone Subtex Texture15mm for Ceiling can be installed with plumb, line & level of theframe work in all respect as per the specification and directionof the Engineer incharge

130 1769.58 230044.92

Total 0.00 230044.92Cost After Index 0.00 230044.92

5

Page 87: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

DSR Amounrt

Non DSR AmounrtSl.No DescriptionDSR Item Unit Qty DSR Rate Non DSR

Rate

E NS Stage Ceiling:Providing and fixing Anutone Subtex Ebony Square edge 15mmfor Ceiling of size 595x595x15 mm is to be installed on frameworkof Anutone Skelet T24 black. Which will comprise of NRC 0.94base panel with water waper absorption of 95% RH as per ASTMC-165 ,ASTM C-303 , ASTM C-1104, ASTM C-1338 and low lightreflectance with Leed points Green Performance certified, withnormal edge profile. Anutone Subtex Ebony 15mm for Ceilingtile meet the stringent fire test required having Class ‘A’ ratingfor Flame Ignitability test as per ASTM-E-84, with completeframework of Anutone SoundSkelet as per Installation detailsgivenProviding and fixing of Anutone Subtex Ebony Square edge ofsize 595X595X15mm on Skelet T24 black in Ceiling laid on framework of ASP Anutone Skelet T24 black Frame Accessories pre-coated GI angle size 24X24X0.40 mm thick fixed to the brick wall/ partition at the perimeter of ceiling with Nylon Sleeves and ASPwafer head drywall screws, Then Suspended main GI’T’ section(bottom precoated-Black) with polyester coating of 25 micronsdry film thickness. Main T-section size 24X38X0.30 mm thick and3600 mm long from soffit in one direction with the help of ASPmetal rawl plug, cleat, leveler, perimeter, wall spring clip & GIRod 4 mm diameter with galvanized spring steel level clip 1200mm centres from soffit . GI cross T section (bottom precoated-Black) size 24X25X0.30 mm and 1200 & 600 mm long is insert fixedinto the slots provided as interlock in main ‘T’ at 600 mm centresto form 600X600 mm grid size for a tile size of 595X595 mm. Whichwill comprise of NRC 0.94 base panel with humidity resistance of90% with Leed points Green Performance certified, and Thermal

conductivity K=0.082 W/MK with sag resistance with normal edge 27 1724.17 46552.69

Total 0.00 46552.69Cost After Index 0.00 46552.69

6

Page 88: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

DSR Amounrt

Non DSR AmounrtSl.No DescriptionDSR Item Unit Qty DSR Rate Non DSR

Rate

F NS Stage Wall Paneling:Providing and fixing Anutone MAT-Ebony Tile of size 600x600x15mm ND6 is to be installed on framework of Anutone Strut. Whichwill comprise of NRC 0.9. Anutone MAT-Ebony meet the stringentfire test required having Class ‘P’ rating for ignitability test as perBS 476 part 5 and Class ‘1’ rating as per BS 476 part 7 for surfacespread of flame test. Class ‘P’ and Class ‘1’ are the highestrating. BS 476 part 6 fire propagation index and flaming ISO 1182and smoke density as per ASTM E 662 besides base panelconforms to EN 13168 2000 with complete framework of AnutoneStrut as per Installation details given

Anutone MAT-Ebony is to be fixed on ASP Anutone Strut channel& stud of G I section of prime quality cold rolled steel as per IS513 hot dipped galvanized 120 gsm as per BS 2989 and zinccoating as per IS 277 on CC-50 main channel and FC-52 on floorand ceiling channel is to be fixed with plastic sleeves andwooden screws to from the proper framework. The Synth AW10x50 of density should be filled in cavity of GI framework of Strutfor better insulation & comfort conditions. TheMain channel willcome at every 600 centre to centre to be fixed with woodenscrews ,plastic sleeves to from framework. Anutone MAT-Ebony isto be fixed on channel with the help of steel screws at every 230mm distance interval and 10 mm away from the edges of Tile forproper holding the tile with the GI framework in line & level. Asper the specification and direction of the Engineer incharge

100 2860.58 286057.89

Total 0.00 286057.89Cost After Index 0.00 286057.89

7

Page 89: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

DSR Amounrt

Non DSR AmounrtSl.No DescriptionDSR Item Unit Qty DSR Rate Non DSR

Rate

G NS Stage Flooring:Providing and fixing of Anutone Float 50T3P Excelsior 65mmwooden flooring having 50mm thick of base panel of wood fibreto control airborne noise/impact noise and structure borne noisehaving triple isolation composite panel with MB binder dimension 600X1200 tongue groove arrangement with overall thickness oftop layer wooden flooring having 10mm thickness of top layerwooden flooring / leminating flooring of teak patterns which istreated to white and & termite and properly seasoned and spiritpolished for having matt finish on grains of teak wood. (Totalshould be 75mm)The Acoustical Anutone Float floor meet the stringent fire testrequired having Class ‘P’ rating for Ignitability test as per BS 476part 5 and Class ‘1’ rating as per BS 476 part 7 for Surface Spreadof Flame test. Class ‘P’ and Class ‘1’ are the highest rating. BS 476part 6 Fire Propagation index and for Flaming ISO 1182 andSmoke density as per ASTM E 662 besides base panel conform toEN 13168 2001 with complete line and level as per installationdetails given with finish.

27 8471.83 228739.42

Total 0.00 228739.42Cost After Index 0.00 228739.42

8

Page 90: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

PUBLIC ADDRESS SYSTEM WORKS

( PAGE : 1 TO 2 )

Page 91: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.NO DESCRIPTION DSR Amount Non DSR Amount

1Supply, installation, testing and commissioning ofPublic Address System Works 0.00 1231864.00

SUMMARY OF COST

PUBLIC ADDRESS SYSTEM WORKS

1

Page 92: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.NO DESCRIPTION Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

1Supply, installation, testing and commissioning offollowing items as per specifications:-

a Bose 802 III Pro Loudspeaker Each 4

b Bittner Basic 1200 Power Amplifier Each 1

c Bose Free space Model 32 SE Each 2

d Bose Free Space® DS 16S Loudspeaker Each 1

e Bose DXA 2120 Mixer amp 230V UK Each 1

f AT 10D ATLAS SOUND ATTENUATORS Each 1

g Mackie CFX 12 Mixer Each 1

h Bose Panaray Controller II 230 V EU Each 1

i Shure DFR 22E Each 1

j Shure BETA 58 A Each 2

k Shure PGX24/SM58 Handheld Wireless System Each 1

l Shure PGX14/185 Lavalier Wireless System Each 1

m Phillips DVP3256/94 DVD Player Each 1

n Shure 18 inch 418 D/C mic Gooseneck cardioid Each 1

Total cost of work 1 1231864.38 1231864.00

Total 0.00 1,231,864.00Cost After Index 0.00 1,231,864.00

PUBLIC ADDRESS SYSTEM WORKS

2

Page 93: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

LIFT WORKS

( PAGE : 1 TO 2 )

Page 94: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No Description DSR Amount Non DSR Amount

1 LIFT IN ARCHITECTURE BUILDING 0.00 2391550.00

SUMMARY COST OF LIFT

1

Page 95: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

SL.No Description Unit Qty DSR Rate Non DSR Rate DSR Amount Non DSR Amount

1 Providing, installation, commissoning and erection of 8 passengers/544 kg lift with 5years Annual Maintenance Contract (After defect & liabality period)) with necessary spares. Each 1 2391550.00 2391550.00

Total 0.00 2,391,550.00Cost After Index 0.00 2,391,550.00

BILL OF QUANTITIES OF LIFT

2

Page 96: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

HVAC (VRV/VRF) WORKS

( PAGE : 1 TO 8 )

Page 97: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No Description DSR Amount Non DSR Amount

A Variable Refrigerant Volume System 0.00 6076650.00

B Ventilation Works 0.00 212000.00

C Electrical Works 0.00 1185000.00

Total 0.00 7,473,650.00

Estimate for VRV Airconditioning system at NIT,Raipur, Chattishgarh

SUMMARY OF COST

1

Page 98: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. Description Unit Qty. DSR Rate Non DSR Rate DSR Amount Non DSR AmountRs. Rs.

Part A Variable Refrigerant Volume SystemSupply,Installation, testing and commissioning of AIR COOLED & INVERTER/ DIGITAL SCROLL BASED VARIABLE REFRIGERANT VOLUME MODULAR TYPE AIR CONDITIONING SYSTEM with R410A suitable for 415 ± 10% , 50 Hz. The unit shall consist of indoor units and external condensing units and other accessaries as listed below complete in all respects as under:

1 Outdoor UnitSupply,Installation, testing and commissioning of Modular type outdoor condensingunits equipped with highly efficient scroll compressors, with one inverter/digital &other constant speed type compressor(s), special acryl precoated e-Pass heatexchanger,low noise condenser fan with DC motor,auto check function forconnection error, auto address setting ,with nominal capacities as mentioned below:96 HP Heat Pump type LOT 1 1,350,000.00 1,350,000.0(Preferred Size 32 HP X 3 Nos.)

2 Indoor UnitsHi-Wall TypeSupply,Installation, testing and commissioning of Air Cooled Split air-conditioners ofindoor fan coil unit(s) consisting of centrifugal fans, fan motor, DX cooling coil, outercasing, filter, control and power panel , supports etc. complete as per specificationsHi-Wall Type : 1.0TR Nos. 10 26,000.00 260,000.0Hi-Wall Type : 1.5TR Nos. 5 32,000.00 160,000.0Hi-Wall Type : 2.0TR Nos. 8 37,000.00 296,000.0

3 Ceiling Mounted Duct TypeSupply,Installation, testing and commissioning of Air Cooled VRV Ceiling mountedbuilt-in type/ductable type indoor unit(s) consisting of centrifugal fans, fan motor,DX cooling coil, outer casing, filter, control and power panel with remote controletc. both interconnected with copper refrigerant & drain pipe of required length (15M). insulation, full charge of refrigerant gas and oil, M.S. base frame duly primered &painted, supports etc. complete as per specifications and drawings. Ceiling Mounted Duct Type : 3.3 TR Nos. 2 65,000.00 130,000.0Ceiling Mounted Duct Type : 5.5 TR Nos. 3 120,000.00 360,000.0

4 Floor Mounted TypeSupply,Installation, testing and commissioning of Air Cooled VRV Floor mounted typeindoor unit(s) consisting of centrifugal fans, fan motor, DX cooling coil, outercasing, filter, control and power panel with remote control etc. both interconnectedwith copper refrigerant & drain pipe of required length (15 M). insulation, full chargeof refrigerant gas and oil, M.S. base frame duly primered & painted, supports etc.complete as per specifications and drawings.

Estimate for VRV Airconditioning system at NIT,Raipur, Chattishgarh

2

Page 99: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. Description Unit Qty. DSR Rate Non DSR Rate DSR Amount Non DSR AmountRs. Rs.

16 TR Nos. 2 270,000.00 540,000.0

5 Supply,Installation, testing and commissioning of Remote controllers (Corded) for operation of indoor units Nos. 32 3,500.00 112,000.0

6 Supply,Installation, testing and commissioning of Remote controllers (Cordless) for operation of indoor units No. 0 3,000.00 0.0

7 Supply,Installation, testing and commissioning of fittings Y-joints and headers for allIndoor units at both the floors layout as per layout drawings LOT 1 550,000.00 550,000.0

8 Supply,Installation, testing and commissioning of Centralised remote controllers foroperation & status monitoring of indoor units Nos. 3 18,000.00 54,000.0

9 Supply,Installation, testing and commissioning of centralised micoprocessor basedBMS system & controls for monitoring of equipment & metering of energyconsumption at each indoor unit for billing purpose. LOT 1 462,000.00 462,000.0

10 Refrigerant PipingSupply,installation,testing and commissioning of Interconnecting refrigerant pipe

work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation

between each set of indoor & outdoor units as per specifications, all piping

inside the room shall be properly supported with MS hanger & clamps.

41.3 mm O.D. (insulation : 19 mm) Mtrs 50 2,000.00 100,000.0

34.9 mm O.D. (insulation : 19 mm) Mtrs 100 1,500.00 150,000.0

28.6 mm O.D. (insulation : 19 mm) Mtrs 90 1,000.00 90,000.0

22.2 mm O.D. (insulation : 13 mm) Mtrs 75 850.00 63,750.0

19.1 mm O.D. (insulation : 13 mm) Mtrs 50 700.00 35,000.0

15.9 mm O.D. (insulation : 13 mm) Mtrs 150 600.00 90,000.0

12.7 mm O.D. (insulation : 13 mm) Mtrs 100 500.00 50,000.0

9.5 mm O.D. (insulation : 13 mm) Mtrs 200 400.00 80,000.0

6.4 mm O.D. (insulation : 13 mm) Mtrs 50 350.00 17,500.0

Perforated GI Tray with hangers & supports for copper piping (300 mm wide) Mtrs 100 600.00 60,000.0

3

Page 100: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. Description Unit Qty. DSR Rate Non DSR Rate DSR Amount Non DSR AmountRs. Rs.

11 Drain Piping

Supply,installation,testing and commissioning of rigid PVC piping complete withfittings, supports as per specifications and duly insulated with 6 mm thick closedcell nitrile rubber insulation.

40 mm dia Mtrs 50 450.00 22,500.0

32 mm dia Mtrs 200 350.00 70,000.0

25 mm dia Mtrs 300 250.00 75,000.0

12 DuctingSupplying, Installation, Testing and Commissioning of GSS ducting of followingthickness including necessary supports, adjustable dampers, vanes etc complete asper specifications.

13 G.I. Sheet Metal Ducting (Rectangular) 0.63 mm (24 Ga) Sqm 300 600.00 180,000.00.80 mm (22 G) Sqm. 100 700.00 70,000.01.0 mm ( 20 G) Sqm. 20 800.00 16,000.01.2 mm ( 18 G) Sqm. 10 900.00 9,000.0

14 Duct InsulationSupply,installation,testing and commissioning of Closed cell, Fire retardant, selfextinguishing type crossed linked polyethylene insulation density not less than 24Kg/sqM, 'K' value not more than 0.028 Kcal/degC with adhesive tape etc. on ductscomplete as per specification and drawings.13 mm thick Sqm 400 500.00 200,000.09 mm thick Sqm 50 650.00 32,500.0

15 Duct Acoustic LiningSupply,installation,testing and commissioning of Duct acoustic lining with glasswool insulation, coverd with perforated aluminium 26 Ga, sheet, nuts, bolts etc.complete as per specification and drawings. 25 mm Sqm 50 400.00 20,000.0

4

Page 101: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. Description Unit Qty. DSR Rate Non DSR Rate DSR Amount Non DSR AmountRs. Rs.

16 Grilles/Diffusers Supply,installation, testing and commissioning supply and return air grilles/ diffusersas per specifications and drawings including fixing frame of G.I./wooden in falseceiling/walls.

Aluminium supply air grilles with volume control Sqm 5 9,000.00 45,000.0

Aluminium Return air grilles without volume control Sqm 5 7,000.00 35,000.0Duct Volume Control dampers Sqm 10 5,000.00 50,000.0

Aluminium S/A Square diffuser with damper Sqm. 3 9,000.00 27,000.0

Aluminium R/A square diffuser without damper Sqm. 2 6,000.00 12,000.0

Fire Dampers for supply & return air duct Sqm. 10 8,000.00 80,000.0

Motorised Actuaters for fire dampers Nos. 7 10,500.00 73,500.0

Fresh air Louvers with VCD,Bird screen/wire mesh etc. Sqm 4 9,600.00 38,400.0

17 Flexible Duct Connection Supply,installation,testing and commissioning of fire retardant nonporous double

layer flexible canvass connection between each indoor unit and ducting. Nos. 7 1,500.00 10,500.0

Total 0.0 6,076,650.0Cost After Index 0.00 6,076,650.0

5

Page 102: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. Description Unit Qty. DSR Rate Non DSR Rate DSR Amount Non DSR AmountRs. Rs.

Part B:- Ventilation Works

18 Propeller Fan ( Toilet Exhust)Supplying, installation, testing & commissioning of propeller fans with motor,supporting frame with bird screen, access panel complete as per specifications anddrawings.225 mm dia at 5 mm static Nos. 3 4,000.00 12,000.0300 mm dia at 5 mm static No. 1 5,000.00 5,000.0

19 In-Line Fans(For Fresh Air)Supplying, installation, testing & commissioning of inline fans with motor, supporting

frame with bird screen, access panel complete as per specifications and drawings.300 CFM capacity Nos. 2 15,000.00 30,000.0

20 Heat Reclaim Ventillation UnitsSupply,Installation, testing and commissioning of HRV as per specification &drawings588 CFM Nos. 2 75,000.00 150,000.0

21 DuctingSupplying, Installation, Testing and Commissioning of GSS ducting of followingthickness including necessary supports, adjustable dampers, vanes etc complete asper specifications.

22 G.I. Sheet Metal Ducting (Rectangular) 0.63 mm (24 Ga) Sqm 10 600.00 6,000.0

23 Grilles/Diffusers Supply,installation, testing and commissioning supply and return air grilles/ diffusersas per specifications and drawings including fixing frame of G.I./wooden in falseceiling/walls.Aluminium Exhaust air diffuser with damper Sqm. 1 9,000.00 9,000.0

Total 0.0 212,000.0Cost After Index 0.00 212,000.0

6

Page 103: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. Description Unit Qty. DSR Rate Non DSR Rate DSR Amount Non DSR AmountRs. Rs.

Part C:- Electrical Works24 Electrical Panel

Supply, installation, testing and commissioning of panel boards made of 2.0 mmthick steel sheet duly powder coated complete with voltmeter, ammeter, indicatinglights, selector switch, incoming/ outgoing isolators, current operated single phase

preventor Rotry operated handles, CTS contactors, A/M Switch for remote controls

operation complete as per specifications and drawings and as required.Main A.C. Panel-P1Incomer1 No. 250 Amps MCCB TP+NL incoming (drawout type)1 No. 250 Amps aluminium conductor bus bar duly sleeved1 No. electronic energy meter with CTs.1 No. Ammeter with ASS & CTs.1 No. voltmeter with VSS.3 Nos. phase indicating lampsOutgoing6 Nos. 40 Amps MCB TP+NL 15 KA outgoing for each compressor of out door units.

SET 1 300,000.00 300,000.0

25 Control & Transmission WiringSupply,installation,testing and commisioning of control cum transmission wiring of 2core x 1.5 sqmm copper in suitable PVC conduits between indoor and out door unit& outdoor units to central remotes controllers. Mtrs 500 200.00 100,000.0

7

Page 104: VOLUME – IIIengineeringprojects.com/Tender/UploadFiles/1097_Vol.III...DSR Rate (Rs.) Non DSR Rate (Rs.) DSR Amount Non DSR Amount 18 4.13 Applying a coat of residual petroleum bitumen

Sl.No. Description Unit Qty. DSR Rate Non DSR Rate DSR Amount Non DSR AmountRs. Rs.

26 Power CableProviding and fixing of PVC amtrsoured copper cables from panel boards to theunits through walls/ceiling with appropriate clamps and fixing arrangements etc. asper specifications and drawings.

4 Core - 16 mm2 Mtrs 10 750.00 7,500.03 Core - 10 mm2 Mtrs 100 550.00 55,000.03 Core - 6 mm2 Mtrs 100 400.00 40,000.03 Core - 4 mm2 Mtrs 100 375.00 37,500.03 Core - 2.5 mm2 Mtrs 500 250.00 125,000.0

27 IsolatorsWeather proof box with MCB TP+NL of 40 Amps near the outdoor units for isolations

Nos. 6 10,000.00 60,000.0

28 Double earthing continuity conductors between panel boards and equipments asrequired and as per I.E. rules 1956. 6 SWG G.I. Wire. Mtrs 20 5,000.00 100,000.0

29 Underdeck InsulationClosed cell, Fire retardant, self extinguishing type crossed linked polyethylene

insulation density not less than 24 Kg/sqM, 'K' value not more than 0.028 Kcal/degC

with adhesive tape etc. on ducts complete as per specification and drawings.

Thickness 50 mm Sqm. 600 600.00 360,000.00

Total 0.0 1,185,000.0Cost After Index 0.00 1,185,000.0

8