VOLTEX® & VOLTEX DS®

BENTONITE GEOTEXTILE WATERPROOFING SYSTEM

For Cast-in-place Concrete Applications

PRODUCT MANUAL

www.cetco.com

Page 2: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

VOLTEX® & VOLTEX DS® BENTONITE GEOTEXTILE WATERPROOFING

PRODUCT MANUAL

- 2 -

CONTENTSWHAT IS SODIUM BENTONITE?PRODUCT DESCRIPTIONASSOCIATED SYSTEM PRODUCTSACCESSORIESLIMITATIONS

INSTALLATION GUIDELINESSECTION 1: UNDERSLAB INSTALLATION 1.1 Substrate Preparation 1.2 Installation 1.3 Pile Caps & Ground Beams 1.4 Slab Penetrations 1.5 Elevator Pits 1.6EdgeofSlab,BackfilledWalls 1.7EdgeofSlab,PropertyLineWalls SECTION 2: PROPERTY LINE CONSTRUCTION 2.1 Property Line Installation Guidelines 2.2 Soldier Pile & Lagging 2.3SteelSheetPilingRetainingWall 2.4 Earth Formed Shotcrete Retention 2.5Secant/ContiguousPiledRetentionWall SECTION 3: BACKFILLED WALLS 3.1 Surface Preparation 3.2 Installation 3.3BackfilledWallPenetrations 3.4 Terminations 3.5MasonryBlockWalls SECTION 4: SPECIAL CONDITIONS 4.1 Precast Concrete Construction 4.2 Contaminated Conditions

THIS MANUAL CONTAINS THE INSTALLATION GUIDE-LINES FOR THE VOLTEX® AND VOLTEX DS® WATER-PROOFING SYSTEM FOR CAST-IN-PLACE CONCRETE APPLICATIONS, INCLUDING UNDERSLAB, PROP-ERTY LINE WALLS, AND BACKFILLED WALLS. THIS MANUAL DOES NOT COVER SHOTCRETE, MASONRY BLOCK, OR PRECAST CONCRETE APPLICATIONS. FOR APPLICATIONS NOT COVERED IN THIS MANU-AL, CONTACT CETCO FOR SPECIFIC INSTALLATION GUIDELINES. BEFORE INSTALLATION, READ THIS MANUAL TO GAIN FAMILIARITY WITH SPECIFIC PRO-CEDURES AND APPLICATIONS. IN THIS MANUAL THE PRODUCT NAME “VOLTEX” IS USED GENERICALLY FOR ALL VOLTEX® PRODUCT TYPES.

WHAT IS SODIUM BENTONITE?

Sodium bentonite is a non-toxic material of volcanic origin which can be found in various geographical locations. Bentonite is specially processed by CETCO to achieve the highest possible performance for all of our waterproofing products. CETCO also manufacturers a contaminant resistant bentonite to assure optimum performance in moderate saline or contaminated water. Bentonite prevents wa-ter intrusion by forming a dense monolithic membrane upon contact with water. The specially processed bentonite expands under con-finement,forminganimperviousmembranethatwillbemaintainedfor the life of the structure.

PRODUCT DESCRIPTIONVOLTEX®isahighlyeffectivewaterproofingcompositecomprisedoftwopolypropylene geotextiles and sodium bentonite. The two geotextiles are interlocked by a patented needlepunching process which encapsulates andconfinesthebentonite.VOLTEXDS® integrates a polymer liner bond-ed to the outside surface of the nonwoven geotextile. The polymer liner provides extremely low permeabilities for water vapour transmission.

Figure 1 – Cross section illustration of VOLTEX®waterproofingmembranemechanicallybondedtoconcrete

Concrete

Needlepunched geotextilefibres

Granular sodium bentonite

Nonwoven geotextile

VOLTEX® forms a continuous mechanical bond to concrete. This bond is created when VOLTEX®’s strong geotextilefibresareencapsulated by poured concrete as shown in the illustration

Wovengeotextile

Page 3: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

www.cetco.com

Installation of VOLTEX® is fast and easy. Simply position the product into place and fasten. VOLTEX® can be installed on green concrete, in virtually any weather, without the need for primers or adhesives. VOLTEX® can be easily cut on site to form around corners and pene-trations. The result is always a consistent self-sealing membrane.

DURABILITYThe VOLCLAY® sodium bentonite in VOLTEX® is uniformly encapsu-lated between two high-strength woven and non-woven geotextiles. CETCO’s state-of-the-art needlepunching process interlocks the geotextiles, preventing the displacement of bentonite prior to, dur-ing, and after installation. The geotextiles provide superior protection from inclement weather and construction-related damage, without requiring to use a protection course.

SUPERIOR ADHESIONWhenconcreteispouredagainstVOLTEX®, a tenacious mechanical bond is created with VOLTEX®’s high strength geotextile. Independent laboratorytestingconductedinaccordancewithASTMD903(mod.)(Peel Adhesion to Concrete), yields an average adhesion value of2.6 kN/m. The mechanical bond will hold VOLTEX® in intimate contact with the concrete should any ground settlement occur, thereby pre-ventingwatermigrationbetweenthewaterproofingandtheconcrete.

COST EFFECTIVE AND TIME EFFICIENTVOLTEX® is designed to be installed on a properly prepared subgrade, withouttheneedtopouraworkingslab.Theproduct’sinherentflex-ibility allows for easy installation on irregular surfaces and rough property line forming. VOLTEX® can be installed as soon as the forms are stripped; there is no waiting for the concrete to cure.

ASSOCIATED SYSTEM PRODUCTSWATERSTOP-RX® – expanding concrete joint waterstop used around penetrations and applicable concrete joints. Swells upon hy-dration.AQUADRAIN – foundation drainage composite consisting of amouldedprofilecoreandafilterfabric.Includessheetdrainageandbase drain collection.

ACCESSORIESBENTOSEAL® – trowel grade mastic used to detail around penetra-tions, corner transitions and terminations. CETSEAL – single-component polyether general sealant and adhesive.VOLCLAY GRANULES® – active granular material used at detail areas that require additional protection.SEAMTAPE® – premium tape used to seal overlapped membrane edg-esofVOLTEXDS®. AKWASWELL – caulk grade hydrophilic waterstop.

TERMINATION BAR – Min. 25 mm wide aluminum or stainless steel barwithpre-punchedholeson300mmcentringforfastening.CEMENTITIOUS BOARD – 12 mm thick cementitious wall board forprotectionofwaterproofingduringtheremovalofsteelsoldierpilecap and top lagging boards. CETBIT 300 – self-adhering flashingmembraneused for ground levelflashing.TB-BOOT – pre-formed, single piece cover for tie-back heads and soilnails.Threesizesavailable:TB-6SN,TB-8&TB-10.

LIMITATIONSVOLTEX® should only be installed after substrate preparation has been properly completed and is suitable to receive the waterproof-ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placeconcrete forming; use removeable forming products only.

VOLTEX® is designed for below-ground waterproofing applica-tionswhere the product is properly confined. VOLTEX® products should not be installed in standing water or over ice. If ground water contains strong acids, alkalies, or is of a conductivity of 2,500μmhos/cmorgreater,watersamplesshouldbesubmittedto the manufacturer for compatibility testing. ULTRASEAL may be required if contaminated ground water or saltwater conditions exist.

VOLTEX® is designed for use under reinforced concrete slabs 100mmthickorgreateronacompactedearth/gravelsubstrate.VOLTEX® requiresaminimum150mmthickreinforcedconcreteslab if installed over concrete blinding. VOLTEX® is not designed for split-slab plaza deck construction.

VOLTEX® is not designed to waterproof expansion joints. Do not use VOLTEX® on masonry block foundation walls. Consult CETCO for special installation guidelines that ap-ply to shotcrete and precast concrete construction.

In this manual, the product name “VOLTEX” is used generi-cally in the installation and application guidelines for the applicable products: VOLTEX®, VOLTEX CR®, VOLTEX DS® and VOLTEX DSCR®. Refer to the table on the back page for product descriptions and roll sizes. Illustrations are not shown to scale.

Page 4: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

VOLTEX® & VOLTEX DS® BENTONITE GEOTEXTILE WATERPROOFING

PRODUCT MANUAL

- 4 -

INSTALLATION GUIDELINES

Before installing VOLTEX® read this installation manual to gain fa-miliaritywithspecificproceduresandapplications.Forapplicationsnotcovered in thismanual, contactCETCO forspecific installationguidelines.

VOLTEX® is engineered for use under reinforced concrete slabs 100mm thick or greater on a compacted earth/gravel substrate.VOLTEX®requiresaminimum150mmthickreinforcedconcreteslabif installed over concrete blinding. VOLTEX CR®orVOLTEXDSCR® is used in contaminated conditions as determined by a CETCO water sample test.

For hydrostatic conditions, VOLTEX® should be installed under footings and ground beams as shown in Figures 1.6, 1.7 and 1.8. For non-hydrostatic conditions, VOLTEX® should be installed around footingsandgroundbeamsasshowninFigures1.9,1.10and1.11.

Prior to installing VOLTEX® the substrate must be properly prepared. Complete all required elevator pit, sump pit, ground beam and pil-ing work prior to installing VOLTEX® under main slab area. These ar-easmustbecorrectlytiedintotheunderslabwaterproofingtoforma monolithic seal.

1.1 SUBSTRATE PREPARATIONSubstrate may be concrete, earth, sand, or crushed stone. Earth and sandsubstratesshouldbecompactedtoaminimum85%ModifiedProctordensity.Crushedstoneshouldbenolargerthan19mminsize.Substrateshouldbesmoothandwithoutsharpdeflectionsorpockets.

1.2 INSTALLATIONInstall VOLTEX®orVOLTEXDS® over the properly prepared substrate with thedarkgray (woven)geotextilesideup.Overlapalladjoiningedgesaminimumof100mmandstaggersheetendsaminimumof300mm(Figure1.1).Nailorstapleedges togetheras requiredto prevent any displacement before and during concrete placement (Figure1.2).

Whentheslabispouredinsections,VOLTEX® should extend a mini-mum 300 mm beyond the slab edge (Figure 1.3). This enables VOLTEX® to be properly overlapped for subsequent slab section pours. WATERSTOP-RX® should be installed in all applicable slab con-structionjoints(Figure1.3).

SECTION 1 UNDERSLAB INSTALLATION

Figure 1.2 – Secure overlaps together with fasteners

Figure 1.1 – Overlap edges 100mmwith seams staggered 300mm

VOLTEX®

Overlap 100mm Min.

Stagger300mm

DARK GRAY (WOVEN) GEOTEXTILE SIDE UP

Overlap 100mmmin.

Reinforced concrete slab

300mmmin VOLTEX®

WATERSTOP-RX® min. 75 mm coverage

Figure 1.3 – Extend VOLTEX® a minimum 300mm beyond slab edge. Install WATERSTOP-RX® in joint

Page 5: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

www.cetco.com

WATERSTOP-RX® 75 mm min. coverage

Reinforced concrete slab aminimum100mmthick

VOLTEX®

Compacted Substrate

DARK GRAY (WOVEN) GEOTEXTILE SIDE UP

Figure 1.4 – VOLTEX®installeddirectlyovercompactedearth/gravelsubstraterequiresaminimum100mmslab

Reinforced concrete slab aminimum150mmthick

VOLTEX®

Compacted Substrate

Concrete blinding

Figure 1.5 – VOLTEX®installedoverconcreteblindingrequiresaminimum150mmthickreinforcedslab

WATERSTOP-RX® 75 mm min. coverage

DARK GRAY (WOVEN) GEOTEXTILE SIDE UP

Page 6: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

VOLTEX® & VOLTEX DS® BENTONITE GEOTEXTILE WATERPROOFING

PRODUCT MANUAL

- 6 -

HYDROSTATIC CONDITIONS NON-HYDROSTATIC CONDITIONS

VOLTEX®

VOLTEX®

BENTOSEAL® FILLET (min38mmx38mm)

Figure1.6–Slabonfootingdetail(hydrostatic)

WATERSTOP-RX® 75 mm min. coverage

VOLTEX®

BENTOSEAL®

BENTOSEAL® FILLET (min38mmx38mm)

VOLTEX®

Concrete Blinding

Figure1.7–Raisedslabdetailwithconcreteblinding(hydrostatic)

WATERSTOP-RX® 75 mm min. coverage

VOLTEX®

BENTOSEAL®

VOLTEX®

Concrete Blinding

Figure1.10–Raisedslabdetailwithconcreteblinding(non-hydrostatic)

WATERSTOP-RX® 75 mm min. coverage

VOLTEX®

VOLTEX®

Figure1.8–Flushslabdetailpropertylinewall(hydrostatic)

WATERSTOP-RX® 75 mm min. coverage

VOLTEX®

Term Bar & BENTOSEAL®

300mm

Figure1.11–Flushslabdetailbackfilledwall(non-hydrostatic)

WATERSTOP-RX® 75 mm min. coverage

VOLTEX®

BENTOSEAL® FILLET (min38mmx38mm)

Figure1.9–Slabonfootingdetail(non-hydrostatic)

WATERSTOP-RX® 75 mm min. coverage

Term bar and BENTOSEAL®

Page 7: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

www.cetco.com

1.3 PILE CAPS AND GROUND BEAMS

VOLTEX® is typicallynot installedoverpilecapsbutcut tofit tight-ly around pile caps. Then apply a minimum 19mm thick fillet of BENTOSEAL® at intersection of VOLTEX® and the piling (Figure1.12)withVOLCLAY GRANULES under VOLTEX® at the piling edge. BENTOSEAL® should extend onto VOLTEX® and piling a minimum of 50mmat19mmthickness.WATERSTOP-RX® should be installed on topsurfaceofpilecaparoundreinforcingsteel(Figure1.12).

Detailgroundbeamsthesameaspilecaps(Figure1.14)withanon-hydrostatic condition. For hydrostatic conditions, VOLTEX® should be installedundertheentiregroundbeam(Figure1.15).Linethegroundbeam formwork with VOLTEX® prior to placement of reinforcing steel. Leaveaminimum300mmofVOLTEX® at the top of the form to tie intobelowslabwaterproofing.

Figure1.12–PileCapDetail(Hydrostaticcondition)

Figure1.13–PileCapDetail(Non-hydrostaticcondition)

Figure1.14–GroundBeam(Non-hydrostaticcondition) Figure1.15–GroundBeam(Hydrostaticcondition)

WATERSTOP-RX®

Concrete pile

BENTOSEAL®

VOLTEX®

VOLCLAY GRANULES

WATERSTOP-RX®

Steel I-beam

VOLTEX®

WATERSTOP-RX®

50mmthickfilletofBENTOSEAL®

VOLCLAY GRANULES

WATERSTOP-RX® VOLCLAY GRANULES

VOLTEX®

BENTOSEAL®

Pile cap

BENTOSEAL®

Pile

WATERSTOP-RX® Reinforcing steel BENTOSEAL®

VOLTEX®

Ground beam

50mmthick filletof VOLCLAY GRANULES

Ground beam

Reinforcing steelWATERSTOP-RX®

VOLTEX®

Page 8: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

VOLTEX® & VOLTEX DS® BENTONITE GEOTEXTILE WATERPROOFING

PRODUCT MANUAL

- 8 -

1.4 SLAB PENETRATIONS

Cut VOLTEX®tocloselyfitaroundpenetrations(Figure1.16).Trowelaminimum19mmthickfilletofBENTOSEAL® around the penetration tocompletelyfillanyvoidareabetweenVOLTEX® and the penetra-tion(Figure1.16).TheBENTOSEAL® should extend up the penetra-tion about 38 mm and extend onto VOLTEX®. In areas where multiple

penetrations are close together, it may be impractical to cut VOLTEX® to fit around each penetration. Pour VOLCLAY GRANULES a mini-mum 6 mm thick around the penetrations covering the entire sub-stratearea.Withgravelsubstrate,installminimum200mmcollarof VOLTEX® around penetration prior to placing VOLCLAY GRANULES. Then apply a thick layer of BENTOSEAL® around each penetration as detailed(Figure1.18).

Figure 1.16 – BENTOSEAL® troweled around penetrations Figure 1.17 – Slab penetration cross section detail

Figure 1.18 – Multiple pipe penetrations. Trowel BENTOSEAL® around pipes and covering area between the pipes

VOLTEX®

Pipe

BENTOSEAL®

DARK GRAY (WOVEN) GEOTEXTILE SIDE UP

VOLTEX®

VOLCLAY GRANULES

BENTOSEAL®

WATERSTOP-RX® 75 mm min. coverage Pipe

Concrete Blinding Substrate Compacted Earth or Gravel Substrate

Concrete Blinding

WATERSTOP-RX®

BENTOSEAL®

Continue VOLTEX® between pipes VOLTEX®

VOLCLAY GRANULESConcrete blinding substrate

Continue VOLTEX® between pipes

WATERSTOP-RX®

BENTOSEAL®

Gravel substrate

VOLTEX® collar VOLCLAY GRANULES

Page 9: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

www.cetco.com

1.5 ELEVATOR PITS

VOLTEX® should be placed on vertical surfaces and on the substrate below the slab to form a continuous envelope around the elevator pit (Figure1.19). If the vertical soil cut is smoothand stable, VOLTEX®

may be installed directly against the soil. Contain unstable soils with concrete backblinding. Install VOLTEX® directly against the concrete backblinding.Duetovariouselevatorpistonplungerdesigns,consultCETCOforspecific installationanddetailing forpistonplungers thatpenetrate the pit slab.

Figure1.19–VOLTEX® under elevator pit slab and on excavation cut walls

1.6 EDGE OF SLAB, BACKFILLED WALLSWhentheinstallationreachestheouteredgeoftheslab,continueVOLTEX®uptothetopedgeoftheformsinsidesurface(Figure1.20)or extend the VOLTEX® sheet out the top of the form a minimum of 300mm (Figure1.21).At theslabcorner,VOLTEX® should remain in contact with the substrate and the inside surface of the concrete form.

When the slab edge form is removed, any undamaged portion of VOLTEX® extended outside the form should be positioned and se-

curedtothetopoftheconcretefooting.Damagedmaterialoutsidethe form should be cut off and disposed of. Overlap the secured VOLTEX® edgeon topof the footingaminimum150mmwith thesucceedingwallwaterproofing.InstallBENTOSEAL®fillet(min38mmx38mm)atwall-to-footingcornerpriortoinstallingoverlappingwallwaterproofing.

WATERSTOP-RX® should be installed in the perimeter wall/slab inter-section joint as illustrated in Figure 1.22.

Figure1.20–VOLTEX® turned up and secured at top of concrete form Figure 1.21 – Extra tail of VOLTEX® extended out of form and later cut off after concrete pour

300mm min.

VOLTEX®

Compacted substrate

VOLTEX® VOLTEX® secured to top of form before concrete pour

Slab edge form

Compacted substrate

VOLTEX®

Extra tail of VOLTEX® extended out of form. Cut off damaged areas before installing VOLTEX® overlap

Slab edge form

Compacted substrate

WATERSTOP-RX® 75 mm min. coverage

Page 10: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

VOLTEX® & VOLTEX DS® BENTONITE GEOTEXTILE WATERPROOFING

PRODUCT MANUAL

- 10 -

1.7 EDGE OF SLAB, PROPERTY LINE CONSTRUCTIONWherepropertylineretainingwalls,suchassoldierpileandlagging,are used as the outside form, continue the underslab VOLTEX® instal-lationuptheretainingwallaminimum300mmabovethetopedgeoftheslaborfooting(Figure1.22).Theextra300mmsheetextensionis very important since there is no access to the outer edge of the footing after it is poured.

Slab to Wall Corner Transition: Install VOLTEX®orVOLTEXDS® sheethorizontallyoriented(darkgraywovengeotextilefacinginstall-er)withaminimum300mmofthesheetextendingoutontothehori-zontal substrate. The top edge of the sheet must extend a minimum 300mmabovethefinishedslabsurface.SecureVOLTEX® sheet to laggingwallwithwasher-headfastenermaximum600mmoncentre.Overlap edges of adjacent VOLTEX®sheetsaminimum100mm.

If theslab thickness isgreater than600mm, installasecond fullsheet or cut strip of VOLTEX®, horizontally oriented, to meet the 300mmrequirementabovetheslab.Overlaptopedgeofprevioussheetandedgesofadjacentsheetsaminimum100mm.

Base Wall Course:InstallfirstVOLTEX® sheet course on the shoring wallhorizontallyoriented(darkgreywovengeotextilefacinginstaller)over the corner transition sheet, with the bottom edge extending down to the wall/slab transition corner as shown in Figure 1.22. Se-cure VOLTEX® sheet to lagging wall with washer-head fasteners maxi-mum600mmoncentre.OverlapedgesofadjacentVOLTEX® sheets aminimum100mm.

Install underslab VOLTEX® membrane extending to corner transition, overlappingthe300mmsheettailofthecornertransitionsheetin-stalledatthewallbase.Securecorneredgewithfasteners300mmon centre.

Forsteelsheetpilingshoringwalls,first install theVOLTEX® corner transition sheet horizontally oriented with the bottom edge extending minimum300mmoutontothesubstrate.Cutthebottomedgeofthecorner transition sheet at piling transition angles to allow the bottom edgetolayflatontothesubstrate.Pour38mmcontinuousfilletofVOLCLAY GRANULES along base of shoring wall. Then install under-slab VOLTEX®sheetcuttofitcontoursofsteelsheetpiling.Finally,install the base shoring wall VOLTEX® sheet (horizontally oriented)overlapping the corner transition sheet.

Figure1.22–SLAB-TO-WALLTRANSITION–VOLTEX® corner transition sheet should extend past the height of the top of the finishedslablevelaminimum300mmandextendunder theslab300mm

Figure 1.23 – AQUADRAIN100BDDISCHARGEPIPE–Connect AQUADRAIN100BDtowaterdischargepipesusing100BD accessory connections

VOLTEX® under slabVOLTEX® transition sheet at corner installed horizontally oriented

Cast-in-place concrete wall

VOLTEX® base course installed horizontally oriented

Woodlagging

300mm min.

VOLTEX® base course installed horizontally oriented

AQUADRAIN SheetDrain

Woodlagging

300mm min.

AQUADRAIN100BDbasedrainconnected to discharge pipes

VOLTEX® transition sheet at corner installed horizontally oriented

VOLTEX®

DischargePipe

WATERSTOP-RX® 75 mm min. coverage

WATERSTOP-RX® 75 mm min. coverage

300mmBENTOSEAL®

Page 11: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

www.cetco.com

The use of construction techniques described in this section al-low the exterior building dimensions to coincide with the prop-erty line, thereby maximizing use of available land for building. VOLTEX®/VOLTEXDS® has been proven to be one of the most effec-tiveandwidelyusedmeansforwaterproofingpropertylineconstruc-tion. Cast-in-place property line construction methods include soldier pile & lagging, steel sheet piling, earth formed shotcrete retention walls, and secant / contiguous piled walls.

For all property line construction methods, VOLTEX® is in-stalled to the shoring wall prior to concrete placement.Install VOLTEX® or VOLTEX DS® with the dark grey (woven) geotextile inward, facing the installer, away from the shoring wall. Refer to each applicable construction method in Sec-tion 2 for specific substrate preparation and detailing instal-lation guidelines.

AQUADRAINsheetand100BDbasedraincompositesystemshouldbeconnectedtoanoperativewaterdischargesystem(sumppumporgravitytodaylightdischarge).

Protectbentonitewaterproofingproductsfromhydratingbeforema-terial iscontainedwithconcreteorbackfill.Afteranyprecipitation,standingwatershouldbepumpedoffwaterproofingassoonaspos-sible.

Shoring Wall: Excavation work should provide shoring wall in good condition to receive waterproofing system. Wood lagging shoringshould extend to the lowest level of thewaterproofing installationwithanyvoidsorcavitiesexteriorofthelaggingfilledwithcompactedsoil or cementitious grout. Voids or cavities at tie-backs should be filledwithgroutorcompactedsoilprior toVOLTEX® installation. In-terior surface of lagging timbers should be monolithic and tight to-gether with gaps less than 25 mm. Gaps in excess of 25 mm should becompletelyfilledwithcementitiousgroutorothersolidmaterial.

Cut rock excavations and concrete secant / contiguous piled retain-ingwallsmustbesufficientlyplanar. Typicallya shotcreteor groutlayer is required to provide acceptable surface to install VOLTEX®.

Employ constructionmethods to stop water flowing through shor-ingwallpriortowaterproofinginstallation.Ifonlywaterseepage,in-stall polyethylene sheeting over the seepage area prior to installing VOLTEX®. Polyethylene sheeting should extend from seepage eleva-tiontobaseofwalltoprotectentirewaterproofinginstallationatthatarea.

SECTION 2 PROPERTY LINE CONSTRUCTION

Figure1.24–RAISEDSLABCONDITION– Connect AQUADRAIN100BDtowaterdischargepipesusing 100BDaccessoryconnectors

Figure 1.25 – Steel sheet piling to slab transition detail

Cast-in-place concrete wall

AQUADRAIN

VOLTEX®Wood lagging

BENTOSEAL® FILLET (min38mmx38mm)

VOLTEX®

Dischargepipe

AQUADRAIN100BDbasedrainconnected to discharge pipes

VOLTEX® underslab

300mmmin.

VOLCLAY GRANULESfilletin corner over VOLTEX® corner transition sheet

Steel sheetpiling

VOLTEX® base layer horizontally oriented

WATERSTOP-RX® 75 mm min. coverage

WATERSTOP-RX® 75 mm min. coverage

BENTOSEAL®

Retained earth

VOLTEX® corner transition sheet horizontally oriented(installfirst)

VOLTEX® corner transition sheet horizontally oriented(slicedto contour sheet piling)

VOLTEX® cut tofitcontoursof sheet pilesConcrete

blinding

INSTALL VOLTEX® OR VOLTEX DS® WITH DARK GRAY (WOVEN) GEOTEXTILE SIDE FACING INSTALLER

Page 12: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

VOLTEX® & VOLTEX DS® BENTONITE GEOTEXTILE WATERPROOFING

PRODUCT MANUAL

- 12 -

2.1 PROPERTY LINE WALL INSTALLATION GUIDELINESAfter the slab-to-wall corner transition sheet and bottom wall sheet course have been installed per Section 1.7 Page 10, VOLTEX® sheets can be installed either vertically or horizontally oriented. Fasten the VOLTEX® into position with washer-head fasteners maxi-mum600mmoncentrearoundthesheetedge.Installsucceeding VOLTEX®sheetoverlappingtheprevioussheetedge100mm.(Note:Shingle lap seams so that the bottom edge of the upper sheet is over thelowersheetstopedge).

Continue installation up wall until ground level termination detail, or asspecified,staggeringallsheetendsofadjacentrollsaminimum300mm.Donotallowsheetoverlapjointstooccuratsameelevationas concrete construction joints. Plan by chalk lining the location of construction joints.

Penetrations: Install a cut collar of VOLTEX® tightly around the pen-etration;extendingaminimum300mmradius.ApplyBENTOSEAL® over VOLTEX® collar around penetration; extending BENTOSEAL® a minimum 75 mm radius at 6mm thickness. Then install main course of VOLTEX® membrane tightly around the penetration. Finally, detail around penetrationwith 19mm thick fillet ofBENTOSEAL®. Withsleevedpipes,theconcreteworkshouldincludefillingthegapbetween the pipe and the sleeve with non-shrink cementitious grout, mechanical seal by others and install WATERSTOP-RX® to outside of sleeve.

Tie-Back Covers:SelectappropriatesizeTB-Boottofitovertie-backplate and allow proper cast-in-place concrete coverage per project re-quirements.TB-Bootshouldfitoverentiretie-backheadwithoutthetie-back plate or cables in direct contact with the TB-Boot. Prior to TB-Bootinstallation,fillvoidsinretentionwallsubstrateandtie-backheadassemblywithsprayfoam(min.1.38bar)ornon-shrinkgrout.For non-hydrostatic conditions, install and secure AQUADRAIN drain-age composite course per manufacturer’s guidelines to soil reten-tion wall prior to installing TB-Boot. For hydrostatic conditions, install TB-Boot prior to VOLTEX®membrane.Withsoldierpiles, strippileswithwaterproofingmembranepriortoTB-Bootplacement.

Fill pre-formed shape of TB-Boot with 2-part urethane spray foam (min. 1.38 bar) and place over tie-back head before foam setsup. Secure TB-Boot to soil retention system using washer head fasteners along the outside edge of the flat base. Apply 6mmthick by minimum 75 mm wide continuous ring of BENTOSEAL® ontotheflatbasejustoutsideofthe12mmraisedcollar.Install1.2 m by 1.2 m piece of VOLTEX® (withprecuthole incentre tofittightaroundthe12mmraisedcollar)overtheentireflatbasewith outside edges fastened to the retaining wall. Secure inside VOLTEX® edge around raised collar with washer-head fasten-ers that pass through the BENTOSEAL® ring; typical fastener spacing 150mm. Do not install fasteners or puncture TB-Bootinside of the 12 mm raised collar. Apply counter flashing of BENTOSEAL® along VOLTEX® sheet edge around raised collar. Then install VOLTEX® field sheet overlapping outer membraneedgeminimum100mm.

Figure2.1–WALLPENETRATION–CutandsecureVOLTEX® tightly around penetrations and then apply BENTOSEAL®19mmringaroundpenetration and extend over membrane a minimum 75 mm radius at minimum 6 mm thickness

Figure2.2–SLEEVEDWALLPENETRATION–CutandsecureVOLTEX® tightly around penetrations and then apply BENTOSEAL® 19mmringaroundpenetrationandextendovermembrane a min. 75 mm

300mm min.

Woodlagging

300mmVOLTEX® collar around pipe penetration

19mmBENTOSEAL®fillet

WATERSTOP-RX®

Pipe

Cast-in-place concrete wall

VOLTEX®

AQUADRAINSheetDrain

300mm min.

Woodlagging

300mmVOLTEX® collar around pipe penetration

19mmBENTOSEAL®fillet

WATERSTOP-RX®

Pipe

VOLTEX®

AQUADRAINSheetDrain

Pipesleeve,filledwith non-shrink grout

Cast-in-place concrete wall

BENTOSEAL® ring 6 mm x 75 mm min.

BENTOSEAL® ring 6mm x 75 mm min.

Mechanical seal by others

Page 13: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

www.cetco.com

Soldier Pile Stripping: Install a strip of VOLTEX® over all soldier piles with raised lagging hanger bolts, form tie rods, or other irregular surface. VOLTEX®stripshouldextendaminimum150mmtobothsides of the piling. Apply BENTOSEAL®6mmx50mmtoVOLTEX® stripsurfacealongbothedgesofeachsoldierpile(Figure2.6).

Cementitious Board: Prior to installing VOLTEX®/VOLTEXDS® to finishedground level, install12mmthickcementitiouswallboardcentredoversteelsoldierpilefromfinishedgroundelevationtospec-ifieddepththatthetopofsteelsoldierpileandwoodlaggingwillberemoved(Figure2.10).

Ground Termination: Terminate VOLTEX®membrane300mmbe-lowfinishedgroundelevationwithwasher-headfastenersmaximum300mmoncentre.InstallCETBIT300flashingtoprimedconcretesubstrate with bottom edge overlapping top edge of VOLTEX® mem-braneminimum100mm.Overlapallrollendsaminimum100mm

toformacontinuousflashing.Heightofflashingshallbeperprojectdetailsandspecifications.InstallarigidterminationbaralongtopedgeofCETBIT300;fastenedmaximum300mmoncentre.Com-plete ground level termination detail with tooled bead of CETSEAL alongthetopedge,atallpenetrationsthroughtheflashing,andallexposed overlap seams.

Wherelaggingtimbersandthetopendofsteelsoldierpilesarere-moved, repair any waterproofing damaged by the excavation andremoval of the retention wall system. Secure all excavated VOLTEX® overlapseamswithwasher-head fastenersmaximum600mmoncentre;withVOLTEXDS® also apply Seamtape centred along over-lapseams.Backfillshallbeplacedandcompactedtominimum85%Modified Proctor density promptly after waterproofing installation.Backfill should consist of compactable soil or angular aggregate19mmorless)freeofdebris,sharpobjects,andstoneslargerthan19mm.Seeterminationdetails(Figures3.11and3.12,page22).

Figure2.3:TIE-BACKDETAIL–InstallTB-Bootcentredovertie-backthen install main course of VOLTEX® with BENTOSEAL®detailing.Donot fasten boot inside of raised collar around centre formed area

Shoring wall

VOLTEX®

AQUADRAIN sheet drain

2-part urethane expanding spray foam (min.1.38bar)

Soldier pile

Fastener

Use spray foamtofillall voids behind tie-back

Donotfasten boot inside of raised collar

Tie-back head with cables

CETCO pre-formed TB-Boot

BENTOSEAL® 6 mm X 75 mm min. VOLTEX®

Field Sheet

Concrete wall

Fastener

Raised collar

Figure2.3a:TIE-BACKDETAIL–InstallTB-Bootcentredover tie-back then install VOLTEX® with BENTOSEAL®detailing.Donot fasten boot inside of raised collar around centre formed area

Shoring wallSoldier pileFastener

VOLTEX® pile strip

VOLTEX®

Raised collar

TB-Boot

Fastener

Soldier pile

VOLTEX® fieldsheet

Use spray foamtofillall voids behind tie-back

Donotfasten boot inside of raised collar

VOLTEX® pile strip

VOLTEX® pile strip

Tie-back head with cables

CETCO pre-formed TB-Boot

2-part urethane expanding spray foam (min.1.38bar)

VOLTEX®fieldsheet

BENTOSEAL® 6 mm X 75 mm min.

NON-HYDROSTATIC CONDITIONS HYDROSTATIC CONDITIONS

BENTOSEAL®

Soldier pile

AQUADRAIN

BENTOSEAL®

BENTOSEAL®

BENTOSEAL®

Page 14: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

VOLTEX® & VOLTEX DS® BENTONITE GEOTEXTILE WATERPROOFING

PRODUCT MANUAL

- 14 -

2.2 SOLDIER PILE & LAGGING RETAINING WALL

Verify the following substrate preparation work has been completed. Then install VOLTEX® following the property line installation guide-lines in Section 2.1 on page 12 and 13.

Preparation: Gaps between the wood lagging must be no wider than 25 mm. If the gaps between lagging are in excess of 25 mm, thegapsshouldbecompletelyfilledwithcementitiousgrout,wood,extrudedpolystyrene(min.2.75bar)orcompactedsoil(Figure2.4).Ifwaterisflowingthroughthelagging,athinpolyethylenesheetingcanbe installed over the area before VOLTEX® is installed.

In areas with large gaps (up to 63 mm) between lagging, AQUADRAIN sheet drainage composite can be installed over the lag-ging to provide a uniform surface to mount VOLTEX®(Figure2.5).Se-curely fasten AQUADRAIN to the lagging surface with washerhead nails before installing VOLTEX®. Gaps larger than 63 mm between lagging shouldbecompletelyfilledwithgrout,wood,extrudedpolystyrene (min.2.75bar)orcompactedsoilevenifAQUADRAIN is installed prior to VOLTEX®.Donotuseplywoodorothersurfacetreatmentoverlargelagginggapsthatleavesthecavityvoid.Details2.7through2.9onpage 15 illustrate the installation of VOLTEX® over the different wood lagging positions relative to the soldier piling.

Figure 2.4 – VOLTEX® installed directly to wood lagging with gapsfilled.(Cast-in-place concretewall)

Figure 2.5 – AQUADRAIN used to cover gaps in lagging less than63mm.(Cast-in-placeconcretewall)

Woodlagging

VOLTEX®

Grout caps larger than 25 mm

WATERSTOP-RX®

Woodlagging

VOLTEX®

AQUADRAIN

WATERSTOP-RX®

Figure 2.6 – Install VOLTEX® onto soldier pile and wood lagging retaining wall prior to cast-in-place concrete wall

BENTOSEAL® troweled over surface of VOLTEX® strip at both edges of the soldier pile

VOLTEX® strip centred over soldier pile BENTOSEAL®

TB-Boot over tie-back plate

VOLTEX® corner transition sheet installed horizontally oriented

VOLTEX® base wall course installed horizontally oriented

Wood lagging

Tie-back head

Soldier pile

100mm

INSTALL VOLTEX® OR VOLTEX DS® WITH DARK GRAY (WOVEN) GEOTEXTILE SIDE FACING INSTALLER

Page 15: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

www.cetco.com

Wood lagging

Steel piling

VOLTEX® main course

VOLTEX® strip over pile prior to main course

WATERSTOP-RX® (75mmmin. coverage)

BENTOSEAL®

Cast-in-place concrete wall

Woodlagging

Steel piling

Retained earth

VOLTEX® main course

BENTOSEAL® between sheets of VOLTEX®

VOLTEX® strip over pile prior to main course

Fill gap with solid material

Cast-in-place concrete wall

Plate & bolts secure lagging

WATERSTOP-RX® (75mmmin. coverage)

Figure2.8–Laggingsecuredtoinsidesurfaceoffrontpileflange.Install VOLTEX® strip to cover mounting plates and bolts prior to maincourse(PlanView)

Figure2.7–Laggingsecuredtooutsidesurfaceoffrontpileflangeprovidingsmoothsurface(PlanView)

Figure2.9–Laggingsecuredtoinsidesurfaceofbackpileflange. Install BENTOSEAL® and VOLTEX® strip prior to main VOLTEX® course and inward BENTOSEAL®fillet.(PlanView)

Steel piling

Woodlagging

VOLTEX® main courseBENTOSEAL®,applytwofillets–onebefore VOLTEX® strip and one after main course

Cast-in-place concrete wall

WATERSTOP-RX® to exterior of cut rebar hole in steel piling

Rebar

VOLTEX® strip over pile prior to main VOLTEX® course

Anyvoidareamustbefilledwithwoodor solid material

WATERSTOP-RX® (75mmmin. coverage)

Figure2.10–WALLEXCAVATIONATGROUNDLEVEL–Cementitiousboardprotectswaterproofingduringexcavationandremovalofsteelpile top and wood lagging

VOLTEX® Cementitious board

Woodlagging

SteelH-pile,topremoved with excavation work

AQUADRAIN sheet drainCast-in-place concrete wall

Page 16: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

VOLTEX® & VOLTEX DS® BENTONITE GEOTEXTILE WATERPROOFING

PRODUCT MANUAL

- 16 -

Figure 2.11 – Sheet pile interlock detail

Figure 2.12 – Install VOLTEX® onto steel sheet piling retaining wall with washer-head fasteners

2.3 STEEL SHEET PILING RETAINING WALL

Verify the following substrate preparation work has been completed. Then install VOLTEX® following the property line installation guide-lines in Section 2.1 on page 12 and 13. Special knurled washer-head fasteners are recommended to secure VOLTEX® to the steel sheet piling.

Preparation: Trowel a 12 mm thick layer of BENTOSEAL® along all sheet piling knuckles. Fill voids or cavities at tieback plates with ce-mentitious grout or compacted soils. If excessive water is penetrating the sheet piling knuckles, BENTOGROUT® can be injected to the out-sideoftheknuckletostopwaterflow(Figure2.11).ConsultCETCOfor BENTOGROUT® applications and installation guidelines.

Alternate Plywood MethodAlternatively, 12 mm plywood may be fastened to the sheet piling to createaflatsurfaceuponwhichVOLTEX® is fastened. All void spaces betweentheplywoodandsheetpilingmustbefilledwithcompactedearth or concrete. Apply VOLTEX® to plywood following “Property Line Construction” Guidelines in Section 2, Page 11.

BENTOGROUT® injected to exterior sideofsheetpileinterlock(perprojectrequirements)

Retained earth

Sheet piling

VOLTEX®BENTOSEAL®Sheet pile interlock

Cast-in-place concrete wall

VOLTEX® vertical seams should not occur at interlocking of sheet piling

VOLTEX®

WATERSTOP-RX® (75mmmin.coverage)

Retained earth

Steel sheet piling

Completelyfillareabehind plywood with compacted soil or concrete

Optional technique: plywood fastened to sheet piling to form flatsurfacetomountVOLTEX®

INSTALL VOLTEX® OR VOLTEX DS® WITH DARK GRAY (WOVEN) GEOTEXTILE SIDE FACING INSTALLER

Page 17: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

www.cetco.com

2.4 EARTH FORMED SHOTCRETE RETAINING WALLVerify the following substrate preparation work has been completed. Then install VOLTEX® following the property line installation guide-lines in Section 2.1 on page 12 and 13.

Preparation: The surface of the earth formed diaphragm wall must besufficientlyplanartoprovideanadequatelysmoothsurfacetoap-ply VOLTEX®. VOLTEX® can be applied over large, relatively shallow indentations. The surface should not contain voids or sharp protru-sions in excess of 25 mm. Fill all voids with cementitious grout and remove protrusions prior to installing VOLTEX®(Figure2.15).

Figure 2.14 – Earth formed concrete retention wall with concretepilesupports(PlanView)

Figure 2.15 – VOLTEX® installation over an earth formed shotcrete retention wall prior to cast-in-place concrete wall

Figure 2.13 – Grout void area and remove protrusions to provide smooth surface for VOLTEX®

WATERSTOP-RX® 75 mm min. coverage)

Grout irregular areas

VOLTEX®

Cast-in-place concrete wall

Shotcrete retaining wall (non-structural)

Shotcrete retaining wall (non-structural)

VOLTEX®

WATERSTOP-RX®

Cast-in-place concrete wall

Retained earth Concrete pile

Retained earth

Shotcrete retaining wall (non-structural)

VOLTEX®

VOLTEX® corner transition sheet horizontally oriented

Grouted depressions and irregular surfaces

100mm

100mmINSTALL VOLTEX® OR VOLTEX DS® WITH DARK GRAY (WOVEN) GEOTEXTILE SIDE FACING INSTALLER

Page 18: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

VOLTEX® & VOLTEX DS® BENTONITE GEOTEXTILE WATERPROOFING

PRODUCT MANUAL

- 18 -

Figure2.16–CutRockexcavationwithshotcreteappliedtoprovideasmoothsurfaceforwaterproofinginstallation

2.5 SECANT / CONTIGUOUS PILED WALLSVerify the following substrate preparation work has been completed. Then install VOLTEX® following the property line installation guide-lines in Section 2.1 on page 12 and 13.

Preparation: The surface of secant / contiguous piled and cut rock excavationwallsmustbesufficientlyplanartoprovideanadequately

smooth surface to apply VOLTEX®. VOLTEX® can be applied over large, relatively shallow indentations where VOLTEX® can conform tight against the surface. The surface should not contain voids or sharp protrusions in excess of 25 mm. Fill all large recesses between piles with cementitious grout prior to installing VOLTEX®(Figure2.17).Cutrock excavations typically require shotcrete or grout work to provide acceptable surface to install VOLTEX®(Figure2.16).

Figure 2.17 – Fill in recesses between cast piles with grout toprovidesmoothsurface(PlanView)

Retained earth side Pile caisson

VOLTEX® Grout recesses

Cut rock formation from excavation

Shotcrete applied to cut rock surface(non-structural)

VOLTEX® TB-6SNVOLTEX®

WATERSTOP-RX®

BENTOSEAL® detailing

Contiguous piled wall

VOLTEX® fastened to face of piled wall

INSTALL VOLTEX® WITH DARK GREY (WOVEN) GEOTEXTILE FACING INSTALLER

Reinforced concrete wall (min150mmthick)

WATERSTOP-RX®101 (min75mmcover)

BENTOSEAL® fillet (38mmx38mm)

Concrete blinding

Figure2.18–PropertyLineContiguousPiledWallDetail

Page 19: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

www.cetco.com

Install VOLTEX®orVOLTEXDS®withthedarkgray(woven)geotextileside against the concrete wall on cast-inplace concrete foundation walls prior to backfilling. VOLTEX® may be applied as soon as the forms are removed. It is not necessary to wait for the concrete to completely cure. Use VOLTEX® with concrete cast with conventional forms that produce smooth surface.

3.1 SURFACE PREPARATIONFooting should be swept clean of silt, rocks and debris to provide VOLTEX® with direct contact to the concrete in the application area. The wall surface must be properly prepared before VOLTEX® is in-stalled.Areasofsurfacehoneycombingorvoidsshouldbefilledwithcementitious grout or BENTOSEAL®. Protrusions of over 6 mm should be knocked off smooth with the concrete surface. Concrete work should includecompletelyfilling taper-tieholeswithnon-shrinkce-mentitious grout and a piece of WATERSTOP-RX® centred in the wall (Figure3.1).ApplyBENTOSEAL® over exterior grouted surface of all formtieholes(Figure3.1).

3.2 INSTALLATIONBeforeinstallingthefirstcourseofVOLTEX®,installBENTOSEALfillet(min38mmx38mm)atthewall/footinginsidecorner(Figure3.2).

Beginning at the bottom corner of the wall, install VOLTEX® horizon-tally oriented with 1.5 m on one wall and the remainder around the cornerontheotherwallsurface(Figure3.2).CutthebottomedgeofVOLTEX®at thecorneraminimumof150mmsothatVOLTEX® can be extended onto the footing. Fasten VOLTEX® into position with washerheadfastenersmaximum600mmoncentre.Thencutandinstall a VOLTEX® section over the uncovered footing corner area. Apply BENTOSEAL® at the VOLTEX® section to VOLTEX®overlaps.(Figure3.2).

Install adjacent VOLTEX® rolls of the bottom course horizontally ori-ented.Eachrollshouldoverlaptheprecedingrollaminimum100mmandshouldextendontothefootingaminimum150mm.Atverticalinsidecornersapplyacontinuous19mmfilletofBENTOSEAL® di-rectly in the corner prior to installing VOLTEX®(Figure3.3).Staggerallverticaloverlapjointsaminimumof300mm(Figure3.4).Whenhy-drostatic conditions exist, the vertical wall VOLTEX® should cover the entire footingandoverlap theunderslabwaterproofingaminimum150mm(Figure3.6).TapeallVOLTEXDS® membrane overlap seams with CETCO Seamtape.

SECTION 3 BACKFILLED WALLS

Figure 3.2 – Start VOLTEX® at the corner horizontally. Place cut sec-tion at corner and apply BENTOSEAL® at overlaps

Figure 3.1 – Concrete form tie details

Figure3.3–ApplyfilletofBENTOSEAL® to inside corner

Snap-Tie Taper-Tie

Non-shrink groutConcrete Tile BENTOSEAL® exterior

face of form tie

Non-shrink grout

VOLTEX®

Install VOLTEX® around corner

BENTOSEAL®filletunder VOLTEX®

VOLTEX®

BENTOSEAL®

Install VOLTEX® to fitcorner

Install VOLTEX® to fitcorner

19mmfilletofBENTOSEAL®

Inside corner of cast-in-place concrete wall

WATERSTOP-RX®

Page 20: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

VOLTEX® & VOLTEX DS® BENTONITE GEOTEXTILE WATERPROOFING

PRODUCT MANUAL

- 20 -

Figure 3.4 – VOLTEX®installedoncast-in-placebackfilledwall,overlapedges100mmandstaggerverticalendlaps

Backfill: Theexcavatedareashouldbebackfilledandcompactedpromptly after VOLTEX®isinstalled.Useplacedbackfillasaplatformin applying succeeding VOLTEX®courses.Thebackfillmustbecom-pactedtoaminimum85%ModifiedProctordensity.Backfillshouldconsistofcompactiblesoilsorangularaggerate(19mmorless)freeofdebris,sharpobjects,andstonelargerthan19mm.Whenbackfillcannot be placed immediately protect membrane from precipitation and debris by sealing edges to concrete substrate with CETCO SEAMTAPE or tooled bead of CETSEAL. This temporary temination can be left in place covered by subsequent membrane overlap.

Figure3.6–Stepbystepdetailofoutsidewallbasecornerinstallation(hydrostaticcondition)

Figure3.5–MinimumVOLTEXDS®overlapdetail;tapeVOLTEXDS® seams

Min. 100mm

Cast-in-place concrete wall

Washer-headmechanicalfastener

VOLTEXDS®

CETCO Seamtape

Step 1. Step 2.

Step 3. Step 4.

VOLTEX® turned up from underslab

Trowel BENTOSEAL® at corner

CutandfoldfirstVOLTEX® section

Cut and fold second VOLTEX® section

Place third VOLTEX® piece over the previous two sections

Trowel BENTOSEAL® over grouted form-tie holes

VOLTEX®

BENTOSEAL®filletplacedunder VOLTEX® at transition at footing

Stagger end seams a minimum 300mm

Mechanically fasten VOLTEX® maximum 600 mm on centre

Install CETCO Seamtape atVOLTEXDS® membrane overlaps

100mmoverlap

WATERSTOP-RX® (min.75mmcoverage)

150mm

INSTALL VOLTEX® OR VOLTEX DS® WITH DARK GRAY (WOVEN) GEOTEXTILE SIDE AGAINST THE CONCRETE WALL

Term bar and BENTOSEAL®

Page 21: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

www.cetco.com

3.3 BACKFILLED WALL PENETRATIONS

Cut VOLTEX® to closely fit around penetrations. After installing VOLTEX®,trowelaminimum19mmthickfilletofBENTOSEAL® around thepenetrationtocompletelyfillanyspacebetweenthepenetrationand the VOLTEX® edge. The BENTOSEAL® should extend onto the penetration 38 mm and cover VOLTEX®’sedge(Figure3.7).Inareaswhere multiple penetrations are close together, it may be impracti-cal to cut VOLTEX®tofitaroundbaseofeachpenetration.Therefore,applya19mmthickfilletofBENTOSEAL® around each penetration andcovertheentiresurfacebetweenthepenetrations(Figure3.8).Extend BENTOSEAL® 38 mm onto the penetrations.

Figure 3.7 – Single penetration cast-in-place wall detail

Figure3.10–InstallVOLTEX® between penetrations with accessibility. Trowel BENTOSEAL® around penetrations

Figure 3.8 – Cut VOLTEX®tofitaroundpenetrations

Figure3.9–Closemultiplepenetrations.TrowelBENTOSEAL® around and between penetrations

VOLTEX®

Cast-in-place concrete wall

BENTOSEAL® troweled around penetration

Pipe

WATERSTOP-RX® (min.75mmcoverage)

VOLTEX® Apply BENTOSEAL® to cut out area

VOLTEX® cut out around multiple penetrations

WATERSTOP-RX®

VOLTEX®

BENTOSEAL®

Pipe

BENTOSEAL®

Pipe

VOLTEX®

WATERSTOP-RX®

WATERSTOP-RX®

VOLTEX®

BENTOSEAL®

Pipe

BENTOSEAL®

VOLTEX®

BENTOSEAL®

Pipe

VOLTEX®

WATERSTOP-RX®

Page 22: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

VOLTEX® & VOLTEX DS® BENTONITE GEOTEXTILE WATERPROOFING

PRODUCT MANUAL

- 22 -

3.4 GROUND LEVEL TERMINATIONS

Terminate VOLTEX®membrane300mmbelow finished ground el-evationwithwasher-head fastenersmaximum300mmoncentre.InstallCETBIT300flashingtoprimedconcretesubstratewithbottom

edge overlapping top edge of VOLTEX®membraneminimum100mm.Overlapallrollendsaminimum100mmtoformacontinuousflash-ing.Heightofflashingshallbeperprojectdetailsandspecifications.InstallarigidterminationbaralongtopedgeofCETBIT300;fastenedmaximum300mmoncentre.Completegroundlevelterminationde-tail with tooled bead of CETSEAL along the top edge, at all penetra-tionsthroughtheflashing,andallexposedoverlapseams.Groundlevel terminations are illustrated in Figures 3.11 and 3.12.

3.5 MASONRY BLOCK WALLSVOLTEX®isnotrecommendedforwaterproofingmasonryblockwalls.Consult with CETCO regarding recommended products and installa-tion guidelines for masonry block walls.

4.1 PRECAST CONCRETE CONSTRUCTIONConsult CETCO regarding products and special installation guidelines for precast concrete plank decks, precast earth covered roofs, and precast wall construction.

4.2 CONTAMINATED CONDITIONSWhere contaminated ground-water conditions exist, use VOLTEX CR®/VOLTEX DSCR® with contaminant resistant sodium bentonite. VOLTEX CR®/VOLTEXDSCR® resist higher levels of the fol-lowing contaminants: nitrates, phosphates, chlorides, sulfates, lime and organic solvents. Verify suitability of product by submitting a site watersampletoCETCOforWaterCompatibilityTestingpriortoinstal-lation. Contact CETCO for further details.

Forcompatibilitytesting,providetwo(2)litresofsitegroundwaterina clean, unbreakable container. Ship water sample to: Birkenhead Road,Wallasey,UKCH447UB(OR)Szczytno12-100,Korpele13A–Strefa,Poland (OR)Cheste (Valencia)46380,Crta.CV-50,Spain,ATTN: BMG Field Services. Upon analysis, CETCO will provide a writ-ten report evaluating the water’s compatibility with VOLTEX® and rec-ommend any special product and/or installation requirements.

SECTION 4 SPECIAL CONDITIONS

IMPORTANT NOTICEFOR SHOTCRETE, PRECAST CONCRETE, EXPANSION JOINTS AND OTHER APPLICATIONS NOT COVERED IN THIS MANUAL, CONTACT CETCO FOR TECHNICAL ASSIS-TANCE AND INSTALLATION GUIDELINES.

Figure3.11–Terminationatfinishedgroundlevel

CETBIT300

CETBIT300

VOLTEX®

Compactedbackfill see CETCO technical data sheets for guidelines

CETCO approved protection course

Tooled CETSEAL bead

Fasten300mmMAXOC

INSTALL VOLTEX® WITH DARK GRAY (WOVEN) GEOTEXTILE AGAINST CONCRETE

Figure 3.12 – Termination at ground level with brick skin

Cavitytray(byothers)

BENTOSEAL®fillet (5mmx75mm)

Compactedbackfill see CETCO technical data sheets for guidelines

VOLTEX®

Termination bar fasten300mmc/c

DPC(byothers) lapped150mm over VOLTEX®

150mm

150mm

150mm

INSTALL VOLTEX® WITH DARK GRAY (WOVEN) GEOTEXTILE AGAINST CONCRETE

150mmmin

Page 23: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

www.cetco.com

The information and data contained herein is believed to be accurate and reliable.Specificationsandotherinformationcontainedhereinsupersedeall previously printed material and are subject to change without notice. Manufacturer’s warranty of installed system is available. Contact seller for terms and sample documents including all limitations. All goods sold by seller are warranted to be free from defects in material and workmanship. The foregoing warranty is in lieu of and excludes all other warranties not expressly set forth herein, whether expressed or implied by operation of law or otherwise including but not limited to any implied warranties of mer-chantabilityorfitness.Seller shall not be liable for incidental or consequential losses, damages or expenses, directly or indirectly arising from the sale, handling or use of the goods, or from any other cause relating thereto, and seller’s liability hereunderinanycaseisexpresslylimitedtothereplacement(intheform

originallyshipped)ofgoodsnotcomplyingwiththisagreementoratseller’selection, to the repayment of, or crediting buyer with, an amount equal to the purchase price of such goods, whether such claims are for breach of warranty or negligence.Any claim by buyer with reference to the goods sold hereunder for any cause shall be deemed waived by buyer unless submitted to seller in writ-ingwithinthirty(30)daysfromthedatebuyerdiscoveredorshouldofdis-covered, any claimed breach. Materials should be inspected and tested by purchaser prior to their use if productqualityissubjecttoverificationaftershipment.Performanceguar-antees are normally supplied by the applicator.

Note: VOLTEX®waterproofingsystemisnotanexpansionjointmaterial.

LIMITED WARRANTY

PRODUCT TABLEPRODUCT DESCRIPTION

VOLTEX® Bentonitegeotextilewaterproofingmembranewithstandardsodiumbentonite

VOLTEX CR® Bentonitegeotextilewaterproofingmembranewithcontaminantresistantsodiumbentonite

VOLTEXDS® Bentonitegeotextilewaterproofingmembranewithstandardsodiumbentoniteandapolyethylenelinercomponent

VOLTEXDSCR® Bentonitegeotextilewaterproofingmembranewithcontaminantresistantsodiumbentoniteandapolyethylenelinercomponent

IMPORTANT NOTICEContact CETCO for verification of specification and instal-lation requirements to comply for eligibility of HydroShield Warranty.

Page 24: VOLTEX & VOLTEX DS · 2016. 6. 13. · into below slab waterproofing. Figure 1.12 – Pile Cap Detail (Hydrostatic condition) Figure 1.13 – Pile Cap Detail (Non-hydrostatic condition)

IMPORTANT: The information contained herein supersedes all previous printed versions, and is believed to be accurate and reliable. For the most up-to-date information, please contact CETCO sales team. CETCO accepts no responsibility for the results obtained through application of this product. CETCO reserves the right to update information without notice.

FORM:PM_VOLTEX_EMEA_EN_201605_V6

www.cetco.com | [email protected]

UPDATED:MAY2016

www.cetco.com

86/1650

1488-CPR-0030/Z1035-CPD-018658

EN13491:2004+EN13491:2004/A1:2006