Vitec-8200-Antiscalant-datasheet-EN-L...Avista Technologies, Inc. Avista Technologies (UK) Ltd....

1
Avista Technologies, Inc. Avista Technologies (UK) Ltd. 7 7 6 6 9 4 4 1 3 1 4 4 + : e n o h P 6 3 5 0 4 4 7 0 6 7 1 + : e n o h P [email protected] [email protected] Visit www.avistatech.com for a list of global offices and distributors. Performance: Vitec ® 8200 anscalant offers a variety of crical performance and applicaon benets: Powerful inhibitor against a variety of carbonate and sulfate scale: CaCO 3 CCPP 900 (LSI 2.5) CaSO 4 4 x Ksp BaSO 4 105 x Ksp SrSO 4 60 x Ksp CaF 2 1000 x Ksp SiO 2 1 x Saturaon Does not contain phosphate or phosphonate. Highly effecve in a wide range of feedwater types and pH ranges. Crystal modificaon property distorts inorganic salt crystal growth, reducing system fouling. Compable with all of the membranes produced by the major manufacturers. Threshold scale inhibion at low dosage rates allows economical system operaon. Vitec ® 8200 is a proprietary anscalant/dispersant that does not contain phosphate or phosphonate. It is an all polymer blend, designed to inhibit scale and disperse colloidal parcles in applicaons where phosphate discharge is limited or restricted. This formulaon is compable with both cellulose acetate and polyamide membranes. It can be injected neat or diluted and used in a wide array of feedwater sources Vitec 8200 has been approved for use in systems producing drinking water by NSF Internaonal under NSF/ANSI Standard 60. Applicaon: Opmum Vitec ® 8200 performance is achieved when the chemical is injected downstream of mulmedia filters and upstream of cartridge filters. Dosing Guidelines: The typical dosage range is between 2 to 5 ppm. A site-specific dose can be determined using the Avista Advisor computer program. Like any injected chemical, over or underdosing may cause unnecessary membrane system fouling. Please contact the Avista customer service department for customized dosing instrucons. Diluon: This product is formulated to be injected neat. However, if a diluon is required, use demineralized or RO permeate water. If neither of these is available, soſtened water may be substuted. The diluon for Vitec 8200 should not result in a soluon strength of less than 1% and DI quality water must be used for any diluons below 10%. This guideline protects the effecveness of the internal bacteriostat which inhibits bacterial growth in the drum and feed tank. Packaging and Storage: Standard regional pack sizes are listed below and custom packaging can be provided worldwide. Informaon on drumless or bulk tanker delivery is available on request. Specificaons Packaging Formats Americas EMEA Appearance: Colorless to light amber liquid Pails 45 lbs - pH (as supplied): 10.5 –11.5 Drums 500 lbs - Specific Gravity@20 o C: 1.15 ± 0.05 IBC’s (totes) 2500 lbs - 02/13 Vitec ® 8200 Anscalant/Dispersant – Liquid Product Datasheet DRINKING WATER TREATMENT ADDITIVES CLASSIFIED BY NSF INTERNATIONAL TO NSF/ANSI 60 AS STANDARD DRINKING WATER TREATMENT CHEMICAL FOR USE IN REVERSE OSMOSIS SYSTEMS AT A MAXIMUM LEVEL OF 7 mg/l Lenntech [email protected] www.lenntech.com Tel. +31-152-610-900 Fax. +31-152-616-289

Transcript of Vitec-8200-Antiscalant-datasheet-EN-L...Avista Technologies, Inc. Avista Technologies (UK) Ltd....

Avista Technologies, Inc. Avista Technologies (UK) Ltd. 7766 944 131 44 + :enohP 6350 447 067 1 + :enohP

[email protected] [email protected]

Visit www.avistatech.com for a list of global offices and distributors.

Performance: Vitec® 8200 antiscalant offers a variety of critical performance and application benefits:

� Powerful inhibitor against a variety of carbonate and sulfate scale:

CaCO3 CCPP ≤ 900 (LSI ≤ 2.5)

CaSO4 4 x Ksp BaSO4 105 x Ksp SrSO4 60 x Ksp CaF2 1000 x Ksp SiO2 1 x Saturation

� Does not contain phosphate or phosphonate.

� Highly effective in a wide range of feedwater types and pH ranges.

� Crystal modification property distorts inorganic salt crystal growth, reducing system fouling.

� Compatible with all of the membranes produced by the major manufacturers.

� Threshold scale inhibition at low dosage rates allows economical system operation.

Vitec® 8200 is a proprietary antiscalant/dispersant that does not contain phosphate or phosphonate. It is an all polymer blend, designed to inhibit scale and disperse colloidal particles in applications where phosphate discharge is limited or restricted.

This formulation is compatible with both cellulose acetate and polyamide membranes. It can be injected neat or diluted and used in a wide array of feedwater sources Vitec 8200 has been approved for use in systems producing drinking water by NSF International under NSF/ANSI Standard 60.

Application: Optimum Vitec® 8200 performance is achieved when the chemical is injected downstream of multimedia filters and upstream of cartridge filters.

Dosing Guidelines: The typical dosage range is between 2 to 5 ppm. A site-specific dose can be determined using the Avista Advisor computer program.

Like any injected chemical, over or underdosing may cause unnecessary membrane system fouling. Please contact the Avista customer service department for customized dosing instructions. Dilution: This product is formulated to be injected neat. However, if a dilution is required, use demineralized or RO permeate water. If neither of these is available, softened water may be substituted. The dilution for Vitec 8200 should not result in a solution strength of less than 1% and DI quality water must be used for any dilutions below 10%. This guideline protects the effectiveness of the internal bacteriostat which inhibits bacterial growth in the drum and feed tank.

Packaging and Storage: Standard regional pack sizes are listed below and custom packaging can be provided worldwide. Information on drumless or bulk tanker delivery is available on request.

Specifications Packaging Formats Americas EMEA

Appearance: Colorless to light amber liquid Pails 45 lbs -

pH (as supplied): 10.5 –11.5 Drums 500 lbs - Specific Gravity@20oC: 1.15 ± 0.05 IBC’s (totes) 2500 lbs -

02/13

Vitec® 8200Antiscalant/Dispersant – Liquid

Product Datasheet

DRINKING WATER TREATMENT ADDITIVESCLASSIFIED BY NSF INTERNATIONAL TONSF/ANSI 60 AS STANDARD DRINKINGWATER TREATMENT CHEMICAL FOR USE INREVERSE OSMOSIS SYSTEMS AT AMAXIMUM LEVEL OF 7 mg/l

[email protected]. +31-152-610-900Fax. +31-152-616-289