Vision Experiment II on White Light Chromaticity for Lighting
Transcript of Vision Experiment II on White Light Chromaticity for Lighting
![Page 1: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/1.jpg)
1 CIE/USA-CNC/CIE 2015
CNC/CIE-CIE/USA Biennial Joint Meeting
Toronto, Canada, Oct. 19-20, 2015
Yoshi Ohno*1 and Semin Oh*2
1 National Institute of Standards and Technology, Gaithersburg, Maryland, USA
Ph. D., President of CIE, NIST Fellow, IESNA Fellow
2 Ulsan National Institute of Science and Technology, South Korea NIST Foreign Guest Researcher
Vision Experiment II on White Light Chromaticity for Lighting
– Duv range perceived most natural
![Page 2: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/2.jpg)
2 CIE/USA-CNC/CIE 2015
Traditional White Light Chromaticity for Lighting
CIE 1931 (x, y) Diagram
ANSI C78.376-2001 for fluorescent lamps IEC 60081 for Fluorescent Lamps
![Page 3: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/3.jpg)
3 CIE/USA-CNC/CIE 2015
ANSI C78.377 (for Solid State Lighting Products)
2011 version 2015 version
Used in Energy Star for SSL products.
Originally published 2008.
![Page 4: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/4.jpg)
4 CIE/USA-CNC/CIE 2015
Chromaticity shift across Planckian Locus
Lights below Planckian
locus look better.
Anecdotes say …
An example in neodymium lamp
Study by LRC on white perception
![Page 5: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/5.jpg)
5 CIE/USA-CNC/CIE 2015
NIST Spectrally Tunable Lighting Facility
![Page 6: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/6.jpg)
6 CIE/USA-CNC/CIE 2015
NIST Spectrally Tunable Lighting Facility
![Page 7: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/7.jpg)
7 CIE/USA-CNC/CIE 2015
![Page 8: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/8.jpg)
8 CIE/USA-CNC/CIE 2015
Experiments conducted at
4 CCTs, at 6 Duv points at
each CCT, at total 23 points.
Total 50 spectra used.
• 18 subjects participated.
• Subject was fully adapted to the
illumination (chromatic adaptation).
• Subjects viewed fruits, vegetables,
his/her skin tone and the whole room.
• Selected lights that looked “more
natural”.
2013 Vision Experiment at NIST
on Preferred and Acceptable level of Duv
![Page 9: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/9.jpg)
9 CIE/USA-CNC/CIE 2015
Percentage of “Not acceptable”
Y. Ohno and M. Fein, Vision Experiment on Acceptable and Preferred White
Light Chromaticity for Lighting, CIE x029:2014, pp. 192 – 199 (2014)
Duv ≈
-0.015
Results of 2013 Experiment Average crossover points of Duv
![Page 10: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/10.jpg)
10 CIE/USA-CNC/CIE 2015
Discussion by M Wei & Kevin Houser
Leukos, April 2015 http://dx.doi.org/10.1080/15502724.2015.1029131
“We infer that the preference expressed by participants in the studies by Dikel and others [2014] and Ohno and Fein [2014] may not be solely related to chromaticity.” “aspects of color rendition (that is, color fidelity and relative gamut) may also influence preference.”
![Page 11: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/11.jpg)
11 CIE/USA-CNC/CIE 2015
![Page 12: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/12.jpg)
12 CIE/USA-CNC/CIE 2015
Color rendering characteristics at different Duv levels
Duv=0 Duv= - 0.03 Duv=0.02
![Page 13: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/13.jpg)
13 CIE/USA-CNC/CIE 2015
Light spectra
![Page 14: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/14.jpg)
14 CIE/USA-CNC/CIE 2015
2015 Experiment at NIST
The same conditions as 2013: • 4 CCTs: 2700 K, 3500 K, 4500 K,
6500 K Duv range: -0.03 to 0.02
• Spectra were similar broadband but adjusted to remove the effects of gamut and chroma saturation.
• 21 subjects (19 to 68 years old) participated.
![Page 15: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/15.jpg)
15 CIE/USA-CNC/CIE 2015
Experimental Setting
• Room was set with neutral white walls. • Illuminance ~300 lx on the table (variations within ±1 %). • Subjects viewed fruits/vegetables on the table, his/her face skin
tone in mirror and the whole room.
![Page 16: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/16.jpg)
16 CIE/USA-CNC/CIE 2015
Preparation for each subject
• Ishihara Test for normal color vision
• Explanations on experiment
• Instructions
• Trial run
![Page 17: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/17.jpg)
17 CIE/USA-CNC/CIE 2015
3500 K
Experimental Design
4500 K
6500 K
2700 K
Experiments prepared for 4 CCTs, at 6 Duv points at each CCT, at total 23 points.
Spectra prepared for the 23 points plus points in between and outside, total 50 points.
Duv defined in ANSI C78377
Adaptation points
![Page 18: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/18.jpg)
18 CIE/USA-CNC/CIE 2015
3500 K
Experimental Procedures
“Is this light acceptable or not?”
![Page 19: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/19.jpg)
19 CIE/USA-CNC/CIE 2015
3500 K
Experimental Procedures
Pair of lights presented alternately. Question: “Which light looks more natural?” Subject answers A or B.
![Page 20: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/20.jpg)
20 CIE/USA-CNC/CIE 2015
3500 K
Experimental Procedures
Pair of lights switched every 3 seconds Question: “Which light looks more natural?” Subject clicked the mouse when more natural light is presented.
“Is this light acceptable or not?”
Next point
![Page 21: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/21.jpg)
21 CIE/USA-CNC/CIE 2015
3500 K
Experimental Procedures
Pair of lights switched every 3 seconds Question: “Which light looks more natural?” Subject clicked the mouse when more natural light is presented.
Pair of lights presented alternately. Question: “Which light looks more natural?” Subject answers A or B.
![Page 22: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/22.jpg)
22 CIE/USA-CNC/CIE 2015
A Which light looks more natural?
![Page 23: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/23.jpg)
23 CIE/USA-CNC/CIE 2015
Which light looks more natural? B
![Page 24: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/24.jpg)
24 CIE/USA-CNC/CIE 2015
Chroma saturation
2013 2015
Adjustment of Spectra in each pair
Chroma saturation 3500 K 3500 K
Gamut area Qg Gamut area Qg
3500 K 3500 K
![Page 25: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/25.jpg)
25 CIE/USA-CNC/CIE 2015
3500 K
Experimental Procedures
Pair of lights switched every 3 seconds Question: “Which light looks more natural?” Subject clicked the mouse when more natural light is presented.
• 6 Duv points each run • 2 directions (runs) • 4 CCTs Total 8 runs, 48 comparisons of pairs of light per subject. Took ~ 2 h per subject. • Whole experiments
not repeated in 2015. 2200 K
• 2200 K for six subjects added. (no control of saturation)
![Page 26: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/26.jpg)
26 CIE/USA-CNC/CIE 2015
Individual Results
![Page 27: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/27.jpg)
27 CIE/USA-CNC/CIE 2015
Results for “Is this light acceptable?”
(6 subjects)
![Page 28: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/28.jpg)
28 CIE/USA-CNC/CIE 2015
Average Results of 2015 Experiment
2013 results 2015 results
No significant differences found.
[In preparation] Y. Ohno and S. Oh, Vision Experiment II on Preferred White
Light Chromaticity for Lighting, CIE 2016, Melbourne, March 2016 (abstract
submitted)
Std.dev
![Page 29: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/29.jpg)
29 CIE/USA-CNC/CIE 2015
Average Results
![Page 30: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/30.jpg)
30 CIE/USA-CNC/CIE 2015
A proposal being prepared in ANSI C78.377 WG
Current specification
Possible addition “Preference-based specification”
• DOE regulation on SSL products (mandatory) coming.
Flexible Duv spec. Center Duv (2200-3000 K) -0.003 -0.006 -0.009 -0.012
Center -0.006
Center -0.012
![Page 31: Vision Experiment II on White Light Chromaticity for Lighting](https://reader033.fdocuments.us/reader033/viewer/2022042410/625ed4e082270f4b69508978/html5/thumbnails/31.jpg)
31 CIE/USA-CNC/CIE 2015
Conclusions
• In response to Wei and Houser study, the 2015 results showed that the preference to negative Duv is caused by the effect of chromaticity shift not due to the associated gamut area change.
• However, it is considered that chroma increase in negative Duv (which occurs in general cases) may also affect (enhance) the preference in the same direction.
• It is verified that the preference for negative Duv is consistent over all CCT ranges (2200 to 6500 K).
• Further experiments or observations with real application scenes are desired.
• Additional specification is considered in ANSI C78.377.
We thank DOE for their partial support of this research.
THANK YOU FOR YOUR ATTENTION. Contact: [email protected]