Virtual surgeries in patients with congenital heart disease: a multi-scale modelling test case by A....

5
Virtual surgeries in patients with congenital heart disease: a multi-scale modelling test case by A. Baretta, C. Corsini, W. Yang, I. E. Vignon-Clementel, A. L. Marsden, J. A. Feinstein, T.-Y. Hsia, G. Dubini, F. Migliavacca, G. Pennati, and Philosophical Transactions A Volume 369(1954):4316-4330 November 13, 2011 ©2011 by The Royal Society

Transcript of Virtual surgeries in patients with congenital heart disease: a multi-scale modelling test case by A....

Page 1: Virtual surgeries in patients with congenital heart disease: a multi-scale modelling test case by A. Baretta, C. Corsini, W. Yang, I. E. Vignon-Clementel,

Virtual surgeries in patients with congenital heart disease: a multi-scale modelling test case

by A. Baretta, C. Corsini, W. Yang, I. E. Vignon-Clementel, A. L. Marsden, J. A. Feinstein, T.-Y. Hsia, G. Dubini, F. Migliavacca, G. Pennati, and

Philosophical Transactions AVolume 369(1954):4316-4330

November 13, 2011

©2011 by The Royal Society

Page 2: Virtual surgeries in patients with congenital heart disease: a multi-scale modelling test case by A. Baretta, C. Corsini, W. Yang, I. E. Vignon-Clementel,

(a) Magnetic resonance flow waveforms measured in the venae cavae (left; black solid line, QSVC; grey solid line, QIVC), superior vena cava (SVC) velocity waveform measured with echo-

Doppler ultrasound (centre) and pressure tracings measured with catheteriz...

A. Baretta et al. Phil. Trans. R. Soc. A 2011;369:4316-4330

©2011 by The Royal Society

Page 3: Virtual surgeries in patients with congenital heart disease: a multi-scale modelling test case by A. Baretta, C. Corsini, W. Yang, I. E. Vignon-Clementel,

Caval (a(i)–d(i)) and pulmonary (a(ii)–d(ii)) volumetric flow rates obtained from: (a) the patient's MR data; (b) the BCPA LPM; (c) the BCPA multi-scale model and (d) the O-TCPC multi-scale

model, as a representative of the post-operative models.

A. Baretta et al. Phil. Trans. R. Soc. A 2011;369:4316-4330

©2011 by The Royal Society

Page 4: Virtual surgeries in patients with congenital heart disease: a multi-scale modelling test case by A. Baretta, C. Corsini, W. Yang, I. E. Vignon-Clementel,

Ventricular pressure–volume loops at rest conditions for the pre- and post-operative models, and under exercise conditions (TCPC EXE) for the offset model.

A. Baretta et al. Phil. Trans. R. Soc. A 2011;369:4316-4330

©2011 by The Royal Society

Page 5: Virtual surgeries in patients with congenital heart disease: a multi-scale modelling test case by A. Baretta, C. Corsini, W. Yang, I. E. Vignon-Clementel,

SVC and IVC pathlines during peak IVC flow for the TCPC models at (left) rest and under (right) exercise conditions.

A. Baretta et al. Phil. Trans. R. Soc. A 2011;369:4316-4330

©2011 by The Royal Society