View SpringConduit InstallationGuide Rev 01d1qmdf3vop2l07.cloudfront.net/snug-woodpecker...P/N...

7
090-101002 Rev 01 ©2015 View, Inc. 1 of 7 Spring Conduit P/N 390-000074-XX Description The Spring Conduit solution provides power and control to operable window units containing View Dynamic Glass. With this solution, an IGU cable can securely traverse between a window frame and the window unit while accommodating various types of hinge movements. Examples of applications include casement, tilt and turn, awning and hopper-style windows. The Spring Conduit installs on the hinged side of the window installation. Spring Conduit Awning Installation Spring Conduit Casement Installation INSTALLATION GUIDE Dynamic Glass

Transcript of View SpringConduit InstallationGuide Rev 01d1qmdf3vop2l07.cloudfront.net/snug-woodpecker...P/N...

Page 1: View SpringConduit InstallationGuide Rev 01d1qmdf3vop2l07.cloudfront.net/snug-woodpecker...P/N 390-000074-XX Specifi cations Installed Length 6 1/4 ± 1/8 in. Installed Depth 3/8

090-101002 Rev 01 ©2015 View, Inc. 1 of 7

Spring ConduitP/N 390-000074-XX

Description

The Spring Conduit solution provides power and control to operable window units containing View Dynamic Glass. With this solution, an IGU cable can securely traverse between a window frame and the window unit while accommodating various types of hinge movements. Examples of applications include casement, tilt and turn, awning and hopper-style windows. The Spring Conduit installs on the hinged side of the window installation.

Spring ConduitAwning Installation

Spring ConduitCasement Installation

INSTALLATION GUIDEDynamic Glass

Page 2: View SpringConduit InstallationGuide Rev 01d1qmdf3vop2l07.cloudfront.net/snug-woodpecker...P/N 390-000074-XX Specifi cations Installed Length 6 1/4 ± 1/8 in. Installed Depth 3/8

090-101002 Rev 01 ©2015 View, Inc. 2 of 7

Spring ConduitP/N 390-000074-XX

Parts Diagram

B

A

C

D

E

Item Qty Part Number Description

A 1 390-000074 Spring Conduit

B 8 500-101116 Screw, Flat Head Phillips, Self-Tapping, 6-32 X 1.000*

*Minimum of 2 screws per conduit base required

Installation Kit Parts

C 1 050-101221 Drill Bit, #52 (1/16")

D 1 050-101500 Step Drill Bit, 3/16"-1/2"

E 1 050-101220 Transfer Punch, #29 (0.136")

INSTALLATION GUIDEDynamic Glass

Page 3: View SpringConduit InstallationGuide Rev 01d1qmdf3vop2l07.cloudfront.net/snug-woodpecker...P/N 390-000074-XX Specifi cations Installed Length 6 1/4 ± 1/8 in. Installed Depth 3/8

090-101002 Rev 01 ©2015 View, Inc. 3 of 7

Spring ConduitP/N 390-000074-XX

Dimensions

MINIMUMOFFSET

1" 25.4mm158.75mm ± 3.175mm

MAXIMUMOFFSET

9.525mmTYPICAL

TO IGU

TO WINDOWCONTROLLER

3/8"

3.175mmTYPICAL1/8"

6 1/4" ± 1/8"

19.05 mmTYPICAL3/4"

19.05 mmTYPICAL3/4"

12.7mmTYPICAL

1/2"

3" 76.2mm

INITIAL LENGTH 6 1/4" ± 1/8" (as shipped, between pilot holes)

INSTALLED LENGTH 6 1/4" ± 1/8" (between pilot holes)

MAXIMUM OFFSET 3" (for parallel off set installations)

INSTALLATION GUIDEDynamic Glass

Page 4: View SpringConduit InstallationGuide Rev 01d1qmdf3vop2l07.cloudfront.net/snug-woodpecker...P/N 390-000074-XX Specifi cations Installed Length 6 1/4 ± 1/8 in. Installed Depth 3/8

090-101002 Rev 01 ©2015 View, Inc. 4 of 7

Spring ConduitP/N 390-000074-XX

Specifi cations

Installed Length 6 1/4 ± 1/8 in.

Installed Depth 3/8 in.

Window Off set Minimum gap space of 3/8 in. between window jamb and window frame

Warranty 5 year warranty

Electrical The Spring Conduit is a low voltage product and is only for use with View IGU cables and controllers manufactured by View Dynamic Glass.This product has IP rated connectors to transfer power and communication to and from the IGU.

Ordering Information

System Part Number Description

390-000074-01 Spring Conduit Assembly* – Clear Anodized

390-000074-02 Spring Conduit Assembly* – Black Anodized

* Includes integrated IGU cable and mounting screws for metal window frames.

Installation KitPart Number

015-101376 See Installation Kit Parts List, Page 3

INSTALLATION GUIDEDynamic Glass

Page 5: View SpringConduit InstallationGuide Rev 01d1qmdf3vop2l07.cloudfront.net/snug-woodpecker...P/N 390-000074-XX Specifi cations Installed Length 6 1/4 ± 1/8 in. Installed Depth 3/8

090-101002 Rev 01 ©2015 View, Inc. 5 of 7

Spring ConduitP/N 390-000074-XX

WINDOW 0FFSET (3/8" MIN.)

WINDOWCONTROLLERDROP CABLE

IGUCABLE

SPRINGCONDUIT

COIL

IGU

DRILL FRAME13mm1/2"

DRILL SASH

FACINGFRAMESURFACE

EXTERIORSASHSURFACE

SPRINGCONDUIT

FRAME-ENDBASE

SPRINGCONDUIT

SASH-ENDBASE

13mm1/2"

6 1/4"159mm

INSTALLATION GUIDEDynamic Glass

Step 1: Determine Locations of Sash and Frame Cable Transfer Holes

1. Prior to glazing or installation of the frame, determine locations for mounting the Spring Conduit to the window sash and frame based on the window type:

• Casement window • Awning window • Hopper window • Tilt and Turn window

2. For windows 18 1/4 inches hinged length, select a location 12 inches from the interior corner of the hinged sash stile or rail nearest the IGU Cable connection, and transfer this measurement to the exterior sash surface. For windows < 18 1/4 inches hinged length, select a location 6 1/4 inches from the interior corner of the hinged sash stile or rail opposite the IGU Cable connection, and transfer this location to the exterior sash surface. Next, determine a center point equal to 1/2 of the sash depth for drilling the sash cable transfer hole to access the IGU cable.

3 Transfer the sash transfer hole center point to the facing surface of the hinged frame jamb, extend the measurement 6 1/4 inches, and determine a center point equal to 1/2 of the jamb depth for drilling tahe frame cable transfer hole to access the Window Controller drop cable.

Page 6: View SpringConduit InstallationGuide Rev 01d1qmdf3vop2l07.cloudfront.net/snug-woodpecker...P/N 390-000074-XX Specifi cations Installed Length 6 1/4 ± 1/8 in. Installed Depth 3/8

090-101002 Rev 01 ©2015 View, Inc. 6 of 7

Spring ConduitP/N 390-000074-XX

Step 2: Drill Cable Transfer Holes in Sash and Frame

1. Drill 1/2" cable transfer holes in the the sash and frame using STEP DRILL BIT (D).

Step 3: Mark Locations of Spring Conduit Sash and Frame Screw Mount Holes

1. Insert Spring Conduit cable and sash-end base into the sash cable transfer hole, and position the unit parallel to the rail or stile as per the fi nal assembly.

• Mark drilling center points for screw mount holes using TRANSFER PUNCH (E) and mallet.

• Remove Spring Conduit from sash.

2. Insert Spring Conduit cable and frame-end base into the frame cable transfer hole, and position the unit parallel to the jamb as per the fi nal assembly.

• Mark drilling center points for screw mount holes using TRANSFER PUNCH (E) and mallet.

• Remove Spring Conduit from frame.

Step 4: Drill Spring Conduit Sash and Frame Screw Mount Holes (Metal Sash/Frame Only)

1. Drill 1/16" screw mount holes in sash and frame using DRILL BIT (C).

Step 5: Mount IGU Sash to Frame and Complete Spring Conduit Installation

1. Pass approximately 2" of the IGU cable and connector through the sash cable transfer hole.

2. Complete assembly of the IGU sash.

3. Position sash relative to frame and secure hinge connections.

4. Connect Spring Conduit sash-end cable to IGU cable.

5. Pass the connected cables through the cable transfer hole, and insert Spring Conduit sash-end base into the hole.

6. Secure Spring Conduit to sash using SCREWS (B).

IGU Cable,Connector2" Extended

INSTALLATION GUIDEDynamic Glass

Page 7: View SpringConduit InstallationGuide Rev 01d1qmdf3vop2l07.cloudfront.net/snug-woodpecker...P/N 390-000074-XX Specifi cations Installed Length 6 1/4 ± 1/8 in. Installed Depth 3/8

090-101002 Rev 01 ©2015 View, Inc. 7 of 7

Spring ConduitP/N 390-000074-XX

Step 6: Mount Spring Conduit to Frame

1. Pass approximately 2" of the Window Controller drop cable and connector through the frame cable transfer hole.

2. Connect Spring Conduit frame-end cable to Window Controller drop cable.

3. Pass the connected cables through the cable transfer hole, and insert Spring Conduit frame-end base into the hole.

4. Secure Spring Conduit to frame using SCREWS (B).

WindowController

Drop Cable,Connector

2" Extended

Step 7: Test Spring Conduit Installation

1. Open and close window to test operation and check for full range of motion.

• Spring Conduit should not stretch beyond the 3" maximum off set length in any position (see page 3).

2. Confi rm minimum 3/8 inch window off set (see page 5).

• Spring Conduit should not fully compress or coil bind in any position.

• Spring Conduit coil should not contact sash or frame in any position.

INSTALLATION GUIDEDynamic Glass