VERGER et DELPORTE - Verger Delporte UAE · PDF fileC E R T I F I E D Energy Industry...

12
C E R T I F I E D Energy Industry Residential Infrastructure VERGER et DELPORTE U.A.E. Ltd. Q U A L I T Y , S I M P L I C I T Y , R O B U S T N E S S A N D R E L I A B I L I T Y final DISTRIBUTION BOARDS final DISTRIBUTION BOARDS final DISTRIBUTION BOARDS final DISTRIBUTION BOARDS CAMGRO SYSTEM CAMGRO SYSTEM CAMGRO SYSTEM CAMGRO SYSTEM

Transcript of VERGER et DELPORTE - Verger Delporte UAE · PDF fileC E R T I F I E D Energy Industry...

C E R T I F I E D

Energy

Industry

Residential

Infrastructure

VERGER et DELPORTE U.A.E. Ltd.

Q U A L I T Y , S I M P L I C I T Y ,

R O B U S T N E S S A N D R E L I A B I L I T Y

final DISTRIBUTION BOARDSfinal DISTRIBUTION BOARDSfinal DISTRIBUTION BOARDSfinal DISTRIBUTION BOARDS

CAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEM

CAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEM

Durable

Enclosures are fabricated from 1.2mm thick

electro galvanized steel sheets.

Fully tested and certified high performance

tin plated bus bar system.

Guaranteed Safety

CAMGRO System is designed and built to

the latest international standards

IEC 61439- 1&2.

Safety is enhanced by thermoplastic barriers

to maintain alignment and isolation between

phases.

Fully shrouded live busbars with dead front

cover and door.

Salient Features

Busbar system is designed for ratings of

125A and 250A.

Wide range of outgoings starting from

12 ways up to 54 ways with a maximum

rating of 63A.

Modular construction.

Electrostatic polyester powder coating in

RAL-7032 shade for corrosion resistance.

Adequate cabling space.

Optimized Maintenance and Operation.

Approved by ADDC and inline with the

requirements of all U.A.E authorities, as well

as inline with the specifications of authorities

in the Gulf countries

Camgro System Final Distribution Boards, delivered

complete with M/s.Schneider Electric components and

integrated within enclosures for high performances up

to 250A for residential, commercial, infrastructure,

industrial and Oil & Gas installations.

Product Features

Wide range of Robust, Reliable and Safe Final Distribution Boards

VERGER et DELPORTE U.A.E. Ltd.

2

Busbar Systems for split type and straight type distribution boards

Technical Specifications

CAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEM

Outgoing connections up to 63A

Busbar types:

Fully type tested encapsulated busbar system

Tin plated copper Busbars

Main Busbar is suitable for MCCBs/Isolators up to 250A and

RCCBs up to 125A

Rating: 125A Split type and 250A straight Busbar type

Short time Withstand currents(Icw) : 17kA for 0.25Sec (125A),

25kA for 0.2Sec. (250A).

RCCB / ISOLATOR

125A

125A

250A

250AIncoming Rating

MCCBType of Incomer

Busbar Rating

Constructional Characteristics

Complies with IEC 61439-1 & 2.

Totally Type Tested, KEMA / DEKRA certified.

Degree of protection conforms to IP 41 as per IEC 60529.

Enclosure with pan assembly and comb busbar.

Multiple knockout holes at top & bottom gland plate.

Suitable for Surface & Flush mounting

Neutral strip is fixed at left side of the distribution boards.

Earth strip is fixed at Right side of the distribution boards.

Suitable for Wall mounting.

Busbar Systems for din rail type Distribution boards

Outgoing connections up to 63A

Busbar types:

Fully insulated comb busbar system

Busbar is suitable for RCCBs / Isolators up to 125A

Rating: 63A and 125A Comb Busbar

ECONOMY

RCCB / ISOLATOR

63A

63A

125A

125AIncoming Rating

RCCB / ISOLATORType of Incomer

Busbar Rating

VERGER et DELPORTE U.A.E. Ltd.

Electrical Characteristics

Rated Operational Voltage (Ue) : 415V.

Rated Insulation Voltage (Ui) : 415V.

Rated Frequency : 50/60Hz.

Rated Current (In) : up to 250A.

Rated Short Time Withstand Current(Icw) : up to 25KA/0.2sec.

Rated Peak Withstand Current (Ipk) : up to 52KA.

Clearance : > 5.5 mm.

Creepage : > 6.3 mm.

3

Standard range of Moulded Case Circuit Breakers conforming to IEC 60947-2

Technical Specifications

505050Breaking Capacity (Icu)

(kA rms) at 415V

Thermal magnetic or Electronic

100%100%

363636

50/60 Hz

Up to 690V

40A….250ARated current (In)

Rated operational voltage(Ue)

Rated frequency

Protection trip unit

200/250

100%

40….100A 125/160ABreaker Rating

Service Breaking Capacity

Ics…………% Icu

Incoming Devices

CAMGROCAMGROCAMGROCAMGRO SYSTEMSYSTEMSYSTEMSYSTEM

Economy range of Moulded Case Circuit Breakers conforming to IEC 60947-2

3625301510

50%

18

125....250A

Up to 550VRated operational voltage(Ue)

40A…. 250ARated current (In)

50/60 HzRated frequency

Thermal magnetic

50%

7.5

40….100ABreaker Rating

Protection trip unit

Service Breaking Capacity

Ics…………% Icu

Breaking Capacity (Icu)

(kA rms) at 415V

Onload Isolators conforming to IEC 60947-1 / IEC 60947-3

154

100A

154

160A

50/60HzRated frequency

Up to 690VRated Operational Voltage(Ue)

154

125A

40A….250A

75 75

80A

330

250A

75

40A 63A

Rated current (In)

Short-circuit making

capacity Icm (kA peak) with

upstream protection circuit

breaker

Isolator rating

VERGER et DELPORTE U.A.E. Ltd.

4

Boards with 250A incomer can be used as SMDB in certain applications( Approved by ADDC)

Boards with 250A incomer can be used as SMDB in certain applications( Approved by ADDC)*

*

RCCBs conforming to IEC 61008,60947-1 & 60947-3

Technical Specifications

63A40A125A100A80A63A40A

ECONOMY

50/60 HzRated frequency

RCCB Sensitivity (mA) 30….30030…50030…300

NORMAL

Up to 415V

25A….125ARated current (In)

Rated operational voltage(Ue)

Type Of RCCB

25A25A 100ARCCB Rating in Amps

Incoming Devices

CAMGROCAMGROCAMGROCAMGRO SYSTEMSYSTEMSYSTEMSYSTEM

MODULAR ISOLATORS conforming to IEC 60669-1 & IEC 60947-3

125A100A63A40A

50/60 HzRated frequency

Up to 400V

40A….125A Rated current (In)

Rated operational voltage(Ue)

32AIsolator Rating

VERGER et DELPORTE U.A.E. Ltd.

5

Accessories / Auxiliaries

Standard range of Miniature Circuit Breakers conforming to IEC 60947-2

CAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEM

Technical SpecificationsOutgoing Devices

15kA10kABreaking capacity (Icu)

3P3P

MCB Rating

50/60 HzRated frequency

Up to 415VRated operational voltage(Ue)

6A….63ARated current (In).

6A….63A

1P

6A….63A

1PNo. of pole

Economy range of Miniature Circuit Breakers conforming to IEC 60898

6kABreaking capacity (Icu)

MCB Rating

50/60 HzRated frequency

Up to 400VRated operational voltage(Ue)

6A….40ARated current (In).

6A…40A

3P

6A...40A

1PNo. of pole

Residual Circuit Breaker with Overload. (RCBO) conforming to IEC 61009 )

10kABreaking capacity (Icu)

50/60 HzRated frequency

30 100

6A….45A6A….45A6A….45ARCBO Rating

10RCBO Sensitivity (mA)

1PNo. of pole

Up to 250VRated operational voltage(Ue)

6A….45ARated current (In).

RCCB ‘ OF ’

contact

Padlocking device Blanking

Plate

‘ MX’ for MCB ‘ OF’ for MCB ‘ MN’ for MCB

VERGER et DELPORTE U.A.E. Ltd.

OF : Display contact MX : Shunt opening release MN : Under voltage release

6

Selection Process

CGF N 12 N FD CAMGRO System

No. of Outgoing ways

12 : 12 ways

18 : 18 ways

24 : 24 ways

30 : 30 ways

CAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEM

Selection of straight Busbar type Final Distribution Boards

N : Standard Range of MCBs

E : Economy range of MCBs

NR : Combination of Standard MCBs and RCBOs

ER : Combination of Economy MCBs and RCBOs

Incoming breaker type

Door Type

FD : Flush Door

SD : Surface Door

Outgoing breaker type

36 : 36 ways

42 : 42 ways

48 : 48 ways

54 : 54 ways

Economy Range of MCCB

E : MCCB

Standard Range of MCCB

N : MCCB

Isolator( 160A….250A )

IS : Isolator

RCCB / Isolator

R : RCCB

I : Isolator ( 32A….125A )

Dimensions

145

145

145

145

118

118

118

D

145

145

145

145

118

118

118

D

1000

850

690

530

850

690

530

H1

1032

882

722

562

882

722

562

H

4571017472100042W, 48W

54W

45786747285024W30W,

36W

45770747269018w

45754747253012w,

45770747269030W, 36W

42W

867

547

H

SURFACE

457

457

W

472

472

W

850

530

H1

FLUSH

12W

18W, 24W

48W,54W

NO. OF

WAYS

MCCB or

160….250A isolator

Incomer

RCCB or

32A…125A

isolator Incomer

VERGER et DELPORTE U.A.E. Ltd.

7

Selection Process

CGF N 66 1RI2R FD CAMGRO System

66 : 6 + 6 way

612 : 6 + 12 way

618 : 6 + 18 way

1212 : 12 + 12, way

CAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEM

Selection of Split Busbar Type Final Distribution Boards

N : Standard Range of MCBs

E : Economy range of MCBs

NR : Combination of Standard MCBs and RCBOs

ER : Combination of Economy MCBs and RCBOs

Incoming breaker type

Door Type

FD : Flush Door

SD : Surface Door

Outgoing breaker type

1218 : 12 + 18 way

1224 : 12 + 24 way

1230 : 12 + 30 way

1236 : 12 + 36 way

Main Incomer

I : Isolator

Dimensions

1000

850

690

530

H1

1000

850

690

530

H1

457

457

457

457

W

1017

867

707

547

H

SURFACE

47210322430, 1836

472

472

472

W

882

722

562

H

FLUSH

1224, 1230,

1236, 1818,

1824, 1830,

2424

66

612, 1212,

618, 1218

NO. OF WAYS

No.of Outgoing Ways ( Single pole ways)

1818 : 18 + 18 way

1824 : 18 + 24 way

1830 : 18 + 30 way

1836 : 18 + 36 way

Section – 1 RCCB

1R : RCCB

Section – 2 RCCB

2R : RCCB

VERGER et DELPORTE U.A.E. Ltd.

8

2424 : 24 + 24 way

2430 : 24 + 30 way

Selection Process

CGF N 6 R FD CAMGRO System

No. of Outgoing ways (Single pole ways)

6 : 6 ways

8 : 8 ways

12 : 12 ways

16 : 16 ways

CAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEM

Selection of Single Phase Final Distribution Boards

N : Standard Range of MCBs

E : Economy range of MCBs

Incoming breaker type

Door Type

FD : Flush Door

SD : Surface Door

Outgoing breaker type

R : RCCB - 2P

I : Isolator – 2P

Dimensions

2972412243122562246 WAYS

457

385

313

W

440

368

296

W1

SURFACE

297

297

297

H

472

400

328

W

31244016 WAYS

312

312

H

368

296

W1

FLUSH

12 WAYS

8 WAYS

NO. OF

WAYS

RCCB or isolator

Incomer

VERGER et DELPORTE U.A.E. Ltd.

9

Selection Process

CGR N 1R R FD CAMGRO System

No. of Rows

1R : 1 Row

2R : 2 Row

3R : 3 Row

CAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEM

Selection of Din rail Type Final Distribution Boards

N : Standard Range of MCBs

E : Economy range of MCBs

Door Type

FD : Flush Door

SD : Surface Door

Outgoing breaker type

4R : 4 Row

5R : 5 Row

6R : 6 Row

457

457

457

457

457

457

457

457

W

472

472

472

472

472

472

472

472

W

SURFACE

HH1

13471330136213308 ROW

11971180121211807 ROW

10471030106210306 ROW

8978809128805 ROW

7477307627304 ROW

597

447

297

580

430

280

H1

612

462

312

H

580

430

280

FLUSH

3 ROW

1 ROW

2 ROW

NO. OF ROWS

Dimensions

7R : 7 Row

8R : 8 Row

Incoming breaker type

R : RCCB

I : Isolator

VERGER et DELPORTE U.A.E. Ltd.

10

Certificates

CAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEM

125A Split Type & 250A Distribution Boards Type Tested Certificates

CAMGRO F1 SYSTEM

125A Split type Final Distribution BoardCAMGRO F2 SYSTEM

250A Distribution Board

CAMGRO F1 SYSTEM

125A Split type Final Distribution Board

Short Circuit Test

CAMGRO F2 SYSTEM

250A Distribution Board

Short Circuit Test

VERGER et DELPORTE U.A.E. Ltd.

11

CAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEM

Contact us

Website : www.verger-delporte.ae Email - [email protected]

Head Office - Sharjah Dubai & Northern EmiratesAbu Dhabi & Al Ain

M. Ramakrishna,

Manager,

P O Box : 5629,

Sharjah, UAE.

Mobile : 00971 50 6314057,

Tel : 00971 6 5432436,

Fax : 00971 6 5434139,

Email : [email protected]

Madhu Murthy Arza

Sales Manager,

P O Box : 5629,

Sharjah, UAE.

Mobile : 00971 50 4620874,

Tel : 00971 6 5432436,

Fax : 00971 6 5434139,

Email : [email protected]

Krishnaraj,

Assistant Manager,

P O Box : 47010,

Abu Dhabi, UAE.

Mobile : 00971 50 7971556,

Tel : 00971 2 6727317,

Fax : 00971 2 6729699,

Email : [email protected]

VDS201107/002, 09-08-2011, REV - 0 12

VERGER et DELPORTE U.A.E. Ltd.