Venting Installation Diagrams & Examples for OnDemand Water Heaters: NovaVent Line JUNE 2012 324192000

Transcript of Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency...

Page 1: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Venting Installation Diagrams & Examples for On‐Demand Water Heaters: 

NovaVent Line 

 

 JUNE 2012  324192‐000 

Page 2: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

TABLE OF CONTENTS 

 3” Intake & 4” Exhaust  

Standard Sidewall Termination – Noncombustible Wall (Example 1) .................................................................. 1A 

Standard Sidewall Termination – Noncombustible Wall (Example 2) .................................................................. 2A 

Standard Sidewall Termination – Noncombustible Wall (Example 3) .................................................................. 3A 

Standard Sidewall Termination – Combustible Wall (Example 1) ......................................................................... 4A 

Standard Sidewall Termination – Combustible Wall (Example 2) ......................................................................... 5A 

Standard Sidewall Termination – Combustible Wall (Example 3) ......................................................................... 6A 

Direct‐Vent Sidewall Termination – Combustible Wall (Example 1)  .................................................................... 7A Direct‐Vent Sidewall Termination – Combustible Wall (Example 2)  .................................................................... 8A Direct‐Vent Sidewall Termination – Combustible Wall (Example 3)  .................................................................... 9A Concentric Direct‐Vent Sidewall Termination (Example 1)  ................................................................................ 10A Concentric Direct‐Vent Sidewall Termination (Example 2)  ................................................................................ 11A Standard Roof Termination (Flat Roof)  .............................................................................................................. 12A Standard Roof Termination (Angled Roof)  ......................................................................................................... 13A Direct‐Vent Roof Termination (Flat Roof)  .......................................................................................................... 14A Direct‐Vent Roof Termination (Angled Roof)  ......................................................................................................15A 

 

4” Intake & 4” Exhaust 

Direct‐Vent Sidewall Termination – Combustible Wall (Example 1)  .................................................................... 7B Direct‐Vent Sidewall Termination – Combustible Wall (Example 2)  .................................................................... 8B Direct‐Vent Sidewall Termination – Combustible Wall (Example 3)  .................................................................... 9B Concentric Direct‐Vent Sidewall Termination (Example 1)  ................................................................................ 10B Concentric Direct‐Vent Sidewall Termination (Example 2)  ................................................................................ 11B Direct‐Vent Roof Termination (Flat Roof)  .......................................................................................................... 14B Direct‐Vent Roof Termination (Angled Roof)  ..................................................................................................... 15B   

5” Intake & 5” Exhaust  

Standard Sidewall Termination – Noncombustible Wall (Example 1) .................................................................. 1C 

Standard Sidewall Termination – Noncombustible Wall (Example 2) .................................................................. 2C 

Standard Sidewall Termination – Noncombustible Wall (Example 3) .................................................................. 3C 

Standard Sidewall Termination – Combustible Wall (Example 1) ......................................................................... 4C 

Standard Sidewall Termination – Combustible Wall (Example 2) ......................................................................... 5C 

Standard Sidewall Termination – Combustible Wall (Example 3) ......................................................................... 6C 

Direct‐Vent Sidewall Termination – Combustible Wall (Example 1)  .................................................................... 7C Direct‐Vent Sidewall Termination – Combustible Wall (Example 2)  .................................................................... 8C Direct‐Vent Sidewall Termination – Combustible Wall (Example 3)  .................................................................... 9C Concentric Direct‐Vent Sidewall Termination (Example 1)  ..................................................................................10C  

Page 3: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

Concentric Direct-Vent Sidewall Termination (Example 2) ................................................................................ 11C Standard Roof Termination (Flat Roof) .............................................................................................................. 12C Standard Roof Termination (Angled Roof) ......................................................................................................... 13C Direct-Vent Roof Termination (Flat Roof) .......................................................................................................... 14C Direct-Vent Roof Termination (Angled Roof) ..................................................................................................... 15C

NOTES: For longer horizontal vent runs, please use support straps every 4 ft., and pitch the run so that any

condensate formed will roll back toward the condensate trap.

Please locate the intake and exhaust sidewall terminations on the same side wall (same pressure zone). The intake and exhaust sidewall terminations should be at least 3 feet apart.

Please follow all local codes when draining condensate.

This illustration is intended as a basic guide only. There is a wide variety Designers must add all necessary safety and auxiliary equipment to conform

to code requirem

These illustrations are intended as basic guides only. There is a wide variety of

situations that will require different parts and/or modifications to these basic

designs. Designers must add all necessary safety and auxiliary equipment to

conform to code requirements and design practices.

Page 4: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

Improper venting of this appliance can result in excessive levels of carbon monoxide which can result in severe personal injury or death.

Improper installation can cause nausea or asphyxiation, severe injury or death from carbon monoxide and flue gases poisoning. Improper installation will void product warranty.

When installing the vent system, all applicable national and local codes must be

followed. If you install thimbles, fire stops or other protective devices and they

penetrate any combustible or noncombustible construction, be sure to follow all

applicable national and local codes.

VENTING INSTRUCTIONS

The water heater must be vented in accordance with the section “Venting of Equipment" of the latest edition of the National Fuel Gas Code: ANSI Z223.1/NFPA 54 in the United States and/or Section 7 of the CAN/CSA B149.1 Natural Gas and Propane Installation Code in Canada, as well as applicable local building codes.

CAUTION

WARNING

Qualified Installer or Service Agency Installation and service of this water heater requires ability equivalent to that of a Qualified Agency (as defined by ANSI below) in the field involved. Installation skills such as plumbing, air supply, venting, gas supply and electrical supply are required in addition to electrical testing skills when performing service. ANSI Z223.1 2006 Sec. 3.3.83: “Qualified Agency” - “Any individual, firm, corporation or company that either in person or through a representative is engaged in and is responsible for (a) the installation, testing or replacement of gas piping or (b) the connection, installation, testing, repair or servicing of appliances and equipment; that is experienced in such work; that is familiar with all precautions required; and that has complied with all the requirements of the authority having jurisdiction.” If you are not qualified (as defined by ANSI above) and licensed or certified as required by the authority having jurisdiction to perform a given task do not attempt to perform any of the procedures described in this manual. If you do not understand the instructions given in this manual do not attempt to perform any procedures outlined in this manual.

Page 5: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

General rules for venting water heaters are:

Place the water heater as close as possible to the vent terminator.

The vent collar of the water heater must be fastened directly to an unobstructed vent pipe.

Do not weld the vent pipe to the water heater’s vent collar.

Do not cut the vent collar of the unit.

The vent must be easily removable from the top of the water heater for normal service and inspection of the unit.

The water heater vent must not be connected to any other gas appliance or vent stack.

Avoid using an oversized vent pipe or using extremely long runs of the pipe.

For rooftop venting, a rain cap or other form of termination that prevents rain water from entering into the water heater must be installed.

Do not common vent or connect any vent from other appliances to the water heater vent.

General rules for vent terminations:

Avoid locating the water heater vent terminator near any air intake devices. These fans can pick up the exhaust flue products from the water heater and return them to the building. This can create a health hazard.

Locate the vent terminator so that it cannot be blocked by any debris, at any time. Most codes require that the terminator be at least 12 inches above grade or anticipated snow level, but the installer may determine if it should be higher depending on the job site condition and applicable codes.

A proper sidewall terminator is recommended when the water heater is vented through a sidewall.

Regarding the clearances from the exhaust terminator to the air inlet or opening, refer to the unit installation manual and venting manufacturer installation manual.

tice.

Page 6: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

Ø5"  DESCRIPTION

9007998005 9008189005 Wall Thimble (4”‐7”)

9007997005  9008190005 Wall Thimble (5”‐10”)

Support

9007989005 9008204005 Support Strap (1")

9007987005 9008181005 6” Straight Vent Pipe

9007986005 9008182005 12” Straight Vent Pipe

9007984005 9008183005 24” Straight Vent Pipe

9007983005 9008184005 36” Straight Vent Pipe

9007982005 9008185005 48” Straight Vent Pipe

Adjustable

9007985005 9008186005Adjustable Vent Pipe          (7.0”‐

9.9”)

9007981005 9008187005 45 Degree Elbow

NovaVentWall Thim

ble

Straight

Elbow

Ø4" 

9007980005 9008188005 90 Degree Elbow

9008146005 9008201005

Universal Adaptor‐3‐in‐1        

(F‐F Adaptor, condensate drain, 

& back‐flow preventer)

9007979005 9008203005 Female‐Female Adaptor

Backflow 

Preventer

9007996005 90082020054” Backflow Preventer & F‐F 

Adaptor

Firestop

9007988005 9008194005 Vertical Firestop

Adaptor

Page 7: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

Ø 5"  DESCRIPTION

9007999005 9008197005 Terminator Hood

9008004005 N/ASidewall Vent Terminator (Hood) 

and Wall Thimble (4”‐7”)

9008005005 N/ASidewall Vent Terminator (Hood) 

and Wall Thimble  (5”‐10”)

9008144005 9008198005  Terminator  Tee

9007995005 N/A Rain Cap

9008145005 9008200005 Extreme Weather Rain Cap

9007994005 9008191005 Drain Tee (Horizontal)

9007993005 9008192005 Drain Tee (Vertical) M‐F

Term

ination

Conden

sation Drain

Ø 4" 

9007992005 9008195005 Flat Roof Flashing

9007991005 9008196005 Angled Roof Flashing

Storm

 Collar

9007990005 9008193005 Storm Collar

Roof Flashing

Page 8: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

Direct Vent Conversion Kit For

T-KJr2(110)/T-K4 (310)/

T-D2 (510)

Direct Vent Conversion Kit For

T-M32 (710/710A)

Direct Vent Conversion Kit For

T-M50 (910/910A)

3" Intake, 4" Exhaust 4" Intake & 4" Exhaust 5" Intake & 5" Exhaust

5.0" to 10.0" 9008147005 9008149005 9008208005

12.0" to 18.0" 9008148005 9008150005 9008209005

3" Intake, 4" Exhaust 4" Intake & 4" Exhaust 5" Intake & 5" Exhaust

5.0" to 10.0" 9008001005 9008206005 9008210005

12.0" to 18.0" 9008000005 9008207005 9008205005

Intake Hood (Galvanized)

Ø3" Ø4" Ø5"

9008142005 9008143005 9008180005

Includes : DV Conversion Kit, Concentric Termination, Universal Adaptor 3-in-1, Aluminum Flex and Gear Clamp

Concentric Direct-Vent Terminaton

9007667005

9007668005

9007669005

Concentric Direct-Vent Termination Kit

Water Heaters DV Conversion Kit

Page 9: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

1A9007999005Sidewall Hood Terminator

900798000590° Elbow

Standard Sidewall Termination - Noncombustible Wall

(Example 1)

90081460054" Universal Appliance Adaptor Kit

1A

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Page 10: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

9007999005Sidewall Hood Terminator

900798000590° Elbow

90081460054" Universal Appliance Adaptor Kit

2A2A

Standard Sidewall Termination - Noncombustible Wall

(Example 2)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

900798300536" Straight Pipe

Page 11: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

9007999005Sidewall Hood Terminator

90081460054" Universal Appliance Adaptor Kit

900798300536" Straight Pipe

900798000590° Elbow

3A

Standard Sidewall Termination - Noncombustible Wall

(Example 3)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

900798300536" Straight Pipe

Page 12: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

4A9008004005Sidewall Hood Terminator and Wall Thimble (4"-7")

9008005005Sidewall Hood Terminator and Wall Thimble (5"-10")

(Please check the wall thickness for proper installation)

90081460054" Universal Appliance Adaptor Kit

900798000590° Elbow

Standard Sidewall Termination - Combustible Wall

(Example 1)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Page 13: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

5A

900798000590° Elbow

900798300536" Straight Pipe

90081460054" Universal Appliance Adaptor Kit

9008004005Sidewall Hood Terminator and Wall Thimble (4"-7")

9008005005Sidewall Hood Terminator and Wall Thimble (5"-10")

(Please check the wall thickness for proper installation)

Standard Sidewall Termination - Combustible Wall

(Example 2)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Page 14: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

6A

900798000590° Elbow

900798300536" Straight Pipe

900798300536" Straight Pipe

90081460054" Universal Appliance Adaptor Kit

9008004005Sidewall Hood Terminator and Wall Thimble (4"-7")

9008005005Sidewall Hood Terminator and Wall Thimble (5"-10")

(Please check the wall thickness for proper installation)

Standard Sidewall Termination - Combustible Wall

(Example 3)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Page 15: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

7A9008004005Sidewall Hood Terminator and Wall Thimble (4"-7")

9008005005Sidewall Hood Terminator and Wall Thimble (5"-10")

(Please check the wall thickness for proper installation)

90081460054" Universal Appliance Adaptor Kit

3" Air Intake Pipe(Not offered)

900798000590° Elbow

90081420053" Air Intake Hood

Direct-Vent Sidewall Termination - Combustible Wall

(Example 1)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Note: For direct-vent sidewall terminations that use two separate penetrations for the intake and exhaust, distance the intake and exhaust terminations at least 3 ft. away from each other, no matter the orientation.

9007667005Direct VentCoversion Kit

Page 16: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

8A9008004005Sidewall Hood Terminator and Wall Thimble (4"-7")

9008005005Sidewall Hood Terminator and Wall Thimble (5"-10")

(Please check the wall thickness for proper installation)

90081460054" Universal Appliance Adaptor Kit

900798200536" Straight Pipe

900798000590° Elbow

90081420053" Air Intake Hood

Direct-Vent Sidewall Termination - Combustible Wall

(Example 2)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Note: For direct-vent sidewall terminations that use two separate penetrations for the intake and exhaust, distance the intake and exhaust terminations at least 3 ft. away from each other, no matter the orientation.

3" Air Intake Pipe(Not offered)

9007667005Direct VentCoversion Kit

Page 17: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

9A

9008004005Sidewall Hood Terminator and Wall Thimble (4"-7")

9008005005Sidewall Hood Terminator and Wall Thimble (5"-10")

(Please check the wall thickness for proper installation)

900798200536" Straight Pipe

90081460054" Universal Appliance Adaptor Kit

900798000590° Elbow

900798200536" Straight Pipe

90081420053" Air Intake Hood

Direct-Vent Sidewall Termination - Combustible Wall

(Example 3)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Note: For direct-vent sidewall terminations that use two separate penetrations for the intake and exhaust, distance the intake and exhaust terminations at least 3 ft. away from each other, no matter the orientation.Note: For direct-vent sidewall terminations that use two separate penetrations for the intake and exhaust, distance the intake and exhaust terminations at least 3 ft. away from each other, no matter the orientation.

3" Air Intake Pipe(Not offered)

9007667005Direct VentCoversion Kit

Page 18: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

10A

90081460054" Universal Appliance Adaptor Kit

90081470054" X 3" Concentric TerminationAdjustable (5"-10")

90081480054" X 3" Concentric TerminationAdjustable (12"-18")3" Flex Pipe

9007667005Direct VentCoversion Kit

Concentric Direct-Vent Sidewall Termination -

(Example 1)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Note:9008001005 Concentric DV Termination Kit (5.0" to 10.0")9008000005 Concentric DV Termination Kit (12.0" to 18.0")Includes:- Direct Vent Conversion Kit- 3X4 Concentric Termination- Universal Adaptor 3-in-1- Aluminum Flex- Gear Clamp

Page 19: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

90081470054" X 3" Concentric TerminationAdjustable (5"-10")

90081480054" X 3" Concentric TerminationAdjustable (12"-18")3" Flex Pipe

90081460054" Universal Appliance Adaptor Kit

11A

Concentric Direct-Vent Sidewall Termination -

(Example 2)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Note:9008001005 Concentric DV Termination Kit (5.0" to 10.0")9008000005 Concentric DV Termination Kit (12.0" to 18.0")Includes:- Direct Vent Conversion Kit- 3X4 Concentric Termination- Universal Adaptor 3-in-1- Aluminum Flex- Gear Clamp

9007667005Direct VentCoversion Kit

900798300536" Straight Pipe

Page 20: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

9007990005Storm Collar

9007995005Extreme Weather Rain Cap or9008145005Rain Cap

9007992005Flat Roof Flashing

9007988005Vertical Firestop

900798300536" Straight Pipe

900798000590° Elbow9008146005

4" Universal Appliance Adaptor Kit

900798300536" Straight Pipe

Standard Roof Termination(Flat Roof)

90079890051" Support Strap

12A

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Page 21: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

900798300536" Straight Pipe

900798000590° Elbow

9007991005Angled Roof Flashing

9007990005Storm Collar

9007988005Vertical Firestop

900798300536" Straight Pipe

90079890051" Support Strap

90081460054" Universal Appliance Adaptor Kit

13A

Standard Roof Termination(Angeled Roof)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

9007995005Extreme Weather Rain Cap or9008145005Rain Cap

Page 22: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

900798600512" Straight Pipe

9007990005Storm Collar

9007992005Flat Roof Flash

900798400524" Straight Pipe

900798300536" Straight Pipe

recommended minimum distance of 4 ft. air intake

(not offered)

9007988005Vertical Firestop

900798000590° Elbow

90081460054" Universal Appliance Adaptor Kit

90079890051" Support Strap

3" air intake pipe(not offered)

14A

Direct-Vent Roof Termination(Flat Roof)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

9007995005Extreme Weather Rain Cap or9008145005Rain Cap

9007667005Direct VentConversion Kit

Page 23: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

900798600512" Straight Pipe

9007988005Vertical Firestop

900798300536" Straight Pipe

900798400524" Straight Pipe

9007991005 Angled Roof Flash

9007990005Storm Collar

90081460054" Universal Appliance Adaptor Kit

90079890051" Support Strap

900798000590° Elbow

recommended minimum

distance of 4 ft. 15A

Direct-Vent Roof Termination(Angled Roof)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

9007995005Extreme Weather Rain Cap or9008145005Rain Cap

9007667005Direct Vent Kit

air intake (not offered)

3" air intake pipe(not offered)

Page 24: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

Direct-Vent Sidewall TerminationCombustible Wall

(Example 1)

7B9008004005Sidewall Hood Terminator and Wall Thimble (4"-7")

9008005005Sidewall Hood Terminator and Wall Thimble (5"-10")

(Please check the wall thickness for proper installation)

90081460054" Universal Appliance Adaptor Kit

900798000590° Elbow

90081430054" Air Intake Hood

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Note: For direct-vent sidewall terminations that use two separate penetrations for the intake and exhaust, distance the intake and exhaust terminations at least 3 ft. away from each other, no matter the orientation.

9007668005Direct Vent Conversion Kit

4" Air intake(Not offered)

Page 25: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

8B9008004005Sidewall Hood Terminator and Wall Thimble (4"-7")

9008005005Sidewall Hood Terminator and Wall Thimble (5"-10")

(Please check the wall thickness for proper installation)

90081460054" Universal Appliance Adaptor Kit

900798000590° Elbow

90081430054" Air Intake Hood

Direct-Vent Sidewall TerminationCombustible Wall

(Example 2)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Note: For direct-vent sidewall terminations that use two separate penetrations for the intake and exhaust, distance the intake and exhaust terminations at least 3 ft. away from each other, no matter the orientation.

4" Air intake(Not offered)

9007668005Direct Vent Conversion Kit

900798300536" Straight Pipe

Page 26: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

9B9008004005Sidewall Hood Terminator and Wall Thimble (4"-7")

9008005005Sidewall Hood Terminator and Wall Thimble (5"-10")

(Please check the wall thickness for proper installation)

900798300536" Straight Pipe

900798300536" Straight Pipe

90081460054" Universal Appliance Adaptor Kit

900798000590° Elbow

90081430054" Air Intake Hood

Direct-Vent Sidewall TerminationCombustible Wall

(Example 3)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Note: For direct-vent sidewall terminations that use two separate penetrations for the intake and exhaust, distance the intake and exhaust terminations at least 3 ft. away from each other, no matter the orientation.

4" Air intake(Not offered)

9007668005Direct Vent Conversion Kit

Page 27: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

Concentric Direct-Vent Sidewall Termination

(Example 1)

10B

90081460054" Universal Appliance Adaptor Kit

90081490054" X 4" Concentric TerminationAdjustable (5"-10")

90081500054" X 4" Concentric TerminationAdjustable (12"-18")

4" Flex Pipe

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Note:9008206005 Concentric DV Termination Kit (5.0" to 10.0")9008207005 Concentric DV Termination Kit (12.0" to 18.0")Includes:- Direct Vent Conversion Kit- 4X4 Concentric Termination- Universal Adaptor 3-in-1- Aluminum Flex- Gear Clamp

9007668005Direct Vent Conversion Kit

Page 28: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

11B90081490054" X 4" Concentric TerminationAdjustable (5"-10")

90081500054" X 4" Concentric TerminationAdjustable (12"-18")

4" Flex Pipe

9007668005Direct Vent Conversion Kit

90081460054" Universal Appliance Adaptor Kit

Concentric Direct-Vent Sidewall Termination

(Example 2)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Note:9008206005Concentric DV Termination Kit (5.0" to 10.0")

9008207005Concentric DV Termination Kit(12.0" to 18.0")

Includes:- Direct Vent Conversion Kit- 4X4 Concentric Termination- Universal Adaptor 3-in-1- Aluminum Flex- Gear Clamp

4"intake air pipe(not offered)

900798300536" Straight Pipe

Page 29: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

14B

Direct-Vent Roof Termination(Flat Roof)

9007995005Extreme Weather Rain Cap or9008145005Rain Cap

900798600512" Straight Pipe

9007990005Storm Collar

9007992005Flat Roof Flash

9007988005Vertical Fire Stop

900798300536" Straight Pipe

90079890051" Support Strap

900798000590° Elbow

90081460054" Universal Appliance Adaptor Kit

air intake(not offered)

recommended min.

distance of 4ft.

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

9007668005Direct Vent Conversion Kit

4"intake air pipe(not offered)

Page 30: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

15B

4"intake air pipe(not offered)

90081460054" Universal Appliance Adaptor Kit

9007988005Vertical Fire Stop

900798300536" Straight Pipe

9007991005Angled Roof Flash

900798600512" Straight Pipe

90079890051" Support Strap

900798000590° Elbow

900798000590° Elbow

recommended min.

distance of 4ft.

9007990005Storm Collar

Direct-Vent Roof Termination(Angled Roof)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

9007995005Extreme Weather Rain Cap or9008145005Rain Cap

9007668005Direct Vent Conversion Kit

air intake(not offered)

Page 31: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

1C

Standard Sidewall Termination -Noncombustible Wall

(Example 1)

9008197005Sidewall Hood Terminator

900818800590° Elbow

90082010055" Universal Appliance Adaptor Kit

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Page 32: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

2C9008197005Sidewall Hood Terminator

90082010054" Universal Appliance Adaptor Kit

900818800590° Elbow

Standard Sidewall Termination -Noncombustible Wall

(Example 2)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

900818400536" Straight Pipe

Page 33: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

3C

9008197005Sidewall Hood Terminator

900818400536" Straight Pipe

90082010054" Universal Appliance Adaptor Kit

900818800590° Elbow

Standard Sidewall Termination -Noncombustible Wall

(Example 3)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

900818400536" Straight Pipe

Page 34: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

4C9008189005 Wall Thimble (4"-7")

9008190005 Wall Thimble (5"-10")

(Please check the wall thickness for proper installation)9008188005

90° Elbow

90082010055" Universal Appliance Adaptor Kit 9008197005

5" Termination Hood

Standard Sidewall Termination -Combustible Wall

(Example 1)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Page 35: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

5C

90082010055" Universal Appliance Adaptor Kit

900818800590° Elbow

900818400536" Straight Pipe

9008189005Wall Thimble (4"-7")

9008190005Wall Thimble (5"-10")

(Please check the wall thickness for proper installation)

90081970055" Termination Hood

Standard Sidewall Termination -Combustible Wall

(Example 2)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Page 36: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

6C

90082010055" Universal Appliance Adaptor Kit

900818400536" Straight Pipe

900818400536" Straight Pipe

900818800590° Elbow

90081970055" Termination Hood

9008189005Wall Thimble (4"-7")

9008190005Wall Thimble (5"-10")

(Please check the wall thickness for proper installation)

Standard Sidewall Termination -Combustible Wall

(Example 3)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Page 37: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

7C

900818800590° Elbow

90081970055" Termination Hood

90081800055" Air Intake Hood

9008189005Wall Thimble (4"-7")

9008190005Wall Thimble (5"-10")

(Please check the wall thickness for proper installation)

Direct-Vent Sidewall Termination -Combustible Wall

(Example 1)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Note: For direct-vent sidewall terminations that use two separate penetrations for the intake and exhaust, distance the intake and exhaust terminations at least 3 ft. away from each other, no matter the orientation.

9007669005Direct Vent Conversion Kit

5" air intake pipe(not offered)

Page 38: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

8C9008189005Wall Thimble (4"-7")

9008190005Wall Thimble (5"-10")

(Please check the wall thickness for proper installation)

90081800055" Air Intake Hood

90081970055" Termination Hood

90082010055" Universal Appliance Adaptor Kit

900818800590° Elbow

Direct-Vent Sidewall Termination -Combustible Wall

(Example 2)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Note: For direct-vent sidewall terminations that use two separate penetrations for the intake and exhaust, distance the intake and exhaust terminations at least 3 ft. away from each other, no matter the orientation.

9007669005Direct Vent Conversion Kit

5" air intake pipe(not offered)

900818400536" Straight Pipe

Page 39: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

9C

90081800055" Air Intake Hood

900818800590° Elbow

900818400536" Straight Pipe

90082010055" Universal Appliance Adaptor Kit

90081970055" Termination Hood

9008189005Wall Thimble (4"-7")

9008190005Wall Thimble (5"-10")

(Please check the wall thickness for proper installation)

Direct-Vent Sidewall Termination -Combustible Wall

(Example 3)

Note: For direct-vent sidewall terminations that use two separate penetrations for the intake and exhaust, distance the intake and exhaust terminations at least 3 ft. away from each other, no matter the orientation.

9007669005Direct Vent Conversion Kit

5" air intake pipe(not offered)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Page 40: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

10C

90082010055" Universal Appliance Adaptor Kit

90082080055" X 5" Concentric TerminationAdjustable (5"-10")

90082090055" X 5" Concentric TerminationAdjustable (12"-18")

5" Aluminum Flex

Concentric Direct-Vent Sidewall Termination

(Example 1)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

9007669005Direct Vent Conversion Kit

Note:9008210005 Concentric DV Termination Kit (5.0" to 10.0")9008205005 Concentric DV Termination Kit (12.0" to 18.0")Includes:- Direct Vent Conversion Kit- 5X5 Concentric Termination- Universal Adaptor 3-in-1- Aluminum Flex- Gear Clamp

Page 41: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

90082010055" Universal Appliance Adaptor Kit

90082080055" X 5" Concentric TerminationAdjustable (5"-10")

90082090055" X 5" Concentric TerminationAdjustable (12"-18")

5" Aluminum Flex

9007669005Direct Vent Conversion Kit

5" air intake pipe(not offered)

11C

Concentric Direct-Vent Sidewall Termination

(Example 2)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

900818400536" Straight Pipe

Note:9008210005 Concentric DV Termination Kit (5.0" to 10.0")9008205005 Concentric DV Termination Kit (12.0" to 18.0")Includes:- Direct Vent Conversion Kit- 5X5 Concentric Termination- Universal Adaptor 3-in-1- Aluminum Flex- Gear Clamp

Page 42: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

Standard Roof Termination(Flat Roof)

900818800590° Elbow9008201005

5" Universal Appliance Adaptor Kit

900818400536" Straight Pipe

9008193005Storm Collar

9008200005Extreme Weather Rain Cap

9008195005Flat Roof Flashing

9008194005Vertical Firestop

900818400536" Straight Pipe

12C

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

Page 43: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

9008196005Angled Roof Flashing 9008193005

Storm Collar

900818400536" Straight Pipe

90082010055" Universal Appliance Adaptor Kit

900818800590° Elbow

900818400536" Straight Pipe

9008194005Vertical Firestop

Support Strap

13C

Standard Roof Termination(Angled Roof)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

9008200005Extreme Weather Rain Cap

Page 44: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

90082010055" Universal Appliance Adaptor Kit

900818800590° Elbow

Support Strap

900818400536" Straight Pipe

9008194005Vertical Firestop

900818300524" Straight Pipe

900818200512" Straight Pipe

9008193005Storm Collar

9008195005Flat Roof Flash

air intake

recommended min. distance of 4 ft. 14C9008200005Extreme Weather Rain Cap

Direct-Vent Roof Termination(Flat Roof)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

9007669005Direct Vent Conversion Kit

5" air intake pipe(not offered)

Page 45: Venting Installation Diagrams Examples for Installation Diagrams & Examples for ... Qualified Agency (as defined by ANSI below) in the field ... the unit installation manual and venting

900818200512" Straight Pipe

9008193005Storm Collar

9008196005Angled Roof Flash

9008194005Vertical Firestop

900818400536" Straight Pipe

900818300524" Straight Pipe

90082010055" Universal Appliance Adaptor Kit

Support Strap

900818800590° Elbow

air intake

recommended min. distance of 4 ft. 15C9008200005Extreme Weather Rain Cap

Direct-Vent Roof Termination(Angled Roof)

These illustrations are intended as basic guides only. There is a wide variety of situations that will require different parts and/or modifications to these basic designs. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practices.

9007669005Direct Vent Conversion Kit

5" air intake pipe(not offered)