VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous...
Transcript of VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous...
![Page 1: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/1.jpg)
VCSO Mechanical
Shock Compensation
![Page 2: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/2.jpg)
Who are we?
Team members: Max Madore Joseph Hiltz-Maher Shaun Hew Shalin Shah Advisor: Helena Silva Phonon contact: Scott Kraft
![Page 3: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/3.jpg)
Original Goals
•Measure Instantaneous Frequency shifts and compare with accelerometer voltage output •Design Compensation circuit based on frequency/voltage characteristics •Test in and implement in 3 axis to determine the unique responses of each
![Page 4: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/4.jpg)
Previous Work
Last Year: •Creation of Shock Tower for repeatable tests •Comparison of two identical VCSOs •Measurement Using Oscilloscope Problems: •Unreliable Data •Mismatched VCSO frequencies
![Page 5: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/5.jpg)
A New Outlook
•Frequency Generator allows for precise matching of generator and test VCSO •MATLAB code allows us to control Shock tower impulse, view multiple trials, filter results digitally •Better understanding of VCSO components and their reaction to shock
![Page 6: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/6.jpg)
• VCSO and mechanical vibration
• Analog filter for compensation of 20dB
• Expand compensation to three axes
Project Overview
![Page 7: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/7.jpg)
Shock Tower
• Uses 24V solenoid to drive a rod against a metal plate
• VCSO and accelerometer sit on the plate and experience shock
• Important to eliminate all erroneous vibration • Resonance • Loose parts
![Page 8: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/8.jpg)
Signal Generator
• Giga-tronics 6060B • 10kHz-1.05GHz • Provides a stable reference that can match
the VCSO’s normal output
![Page 9: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/9.jpg)
Phase Frequency Detector
• Hittite HMC439QS16G • Mixes the signals from the Signal Generator and
VCSO • Outputs a triangular waveform whose frequency is
the difference in frequency of its inputs
![Page 10: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/10.jpg)
Data Acquisition
• National Instruments X series USB-6353 Data Acquisition Card
• MATLAB 2009 on lab computer
• Filtration may be desired to remove high frequency noise • Looking for changes in the hundreds of Hertz or less
• Sample Rate is not fast enough to collect data directly from the VCSO or signal generator
• Also used to fire the solenoid in the shock tower
![Page 11: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/11.jpg)
Last Semester’s Results Phase frequency detector output of uncompensated shock response
![Page 12: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/12.jpg)
Start of Spring Semester
![Page 13: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/13.jpg)
Start of Spring Semester
![Page 14: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/14.jpg)
Current Data
![Page 15: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/15.jpg)
Current Data
![Page 16: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/16.jpg)
Repeatability
![Page 17: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/17.jpg)
Remaining Tasks
![Page 18: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/18.jpg)
Accurately Determine
Acceleration Sensitivity • Most important task to achieving compensation • Data processing and noise filtering have paid off • New accelerometers to move forward • Test each axis and superimpose compensations • Accelerometer Output Attenuation Equation:
• Γ = Acceleration Sensitivity • Fo = Oscillator Frequency • m = Frequency Control Curve Slope • S = Accelerometer Sensitivity
![Page 19: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/19.jpg)
Investigate Magnitude
of EM interference • Solenoid produces large EM field while shocking the VCSO • Has obvious effect on accelerometer • May also affect VCSO output
![Page 20: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/20.jpg)
Investigate Magnitude
of EM interference • Solution: Shock the VCSO manually
![Page 21: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/21.jpg)
Secure Oscillator
Firmly to Shock Tower
• To remove all acceleration other than shock pulse • Currently using hand to hold oscillator
• Inconsistent • Temperature
• Future options: • Clamps • Cloth/Leather Strap
• Introduce as little resonance as possible
![Page 22: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/22.jpg)
Implement New Equipment
• SMD capacitors and resistors for ADXL evaluation board filters
• New shock tower • ADXL377 3-axis Evaluation Board • 3-axis Accelerometer/Oscillator Mount
![Page 23: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/23.jpg)
Equipment to Buy
• ADXL001-500 Evaluation boards • To replace current faulty one • To test in 3 axis • $90 each
• TLC2262CP Operation Amplifiers
• For 3 axis expansion • Low noise • $2.08 per chip • 2 op amps per chip
![Page 24: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/24.jpg)
Circuits to Implement
• Compensation test circuit • Potentiometers for fine tuning attenuation level • Operates around 1V on the VCSO control input • Switches to toggle compensation
• Will be expanded to accommodate 3 axes • Overall gain determined by VCSO acceleration sensitivity
![Page 25: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/25.jpg)
Circuits to Implement • Rational for 1V Operation Point:
• Most linear point on the control input • Still not completely linear • Non-linearity limits compensation
![Page 26: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/26.jpg)
If time allows: • Study delay mismatch
• Isolate each element and estimate its delay
• Greater delay decreases compensation
• Large delay could make compensation impossible
• Study other possible acceleration sensitivity factors, requiring higher filter orders • Vibration Frequency dependence
• Resonance • Control Voltage • Temperature
Further Study
![Page 27: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/27.jpg)
Verification
and Documentation
• Verify compensation at Phonon on larger equipment • Calibrated accelerometers and vibration tables • Phase noise measurements on spectrum analyzer • Random vibration
• Record compensation levels and other data • Interpret results • Compose Final Paper • Demonstrate at Senior Design Day and Phonon
![Page 28: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/28.jpg)
Recap -
Objective and Operation of Device
- Tuning voltage used to regulate frequency output.
- VCSO requires stable frequency output.
- When VSCO is shocked the output of the device is shifted by a
certain phase.
- Phase instability causes frequency domain noise.
- Objective is to suppress this noise with appropriate low pass
filter.
![Page 29: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/29.jpg)
Why stable frequency
needed
For example, in communication system a voltage control
oscillator is used to create a stable frequency reference for
passing information to a required frequency band.
- Phase lock loop
- Computer disk
- Wireless electronics
- Timers
- Clock and data recovery
![Page 30: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/30.jpg)
What are our Goals
• Continue to improve compensation by applying digital filter in
matlab
• Apply 3 axis testing using triple axis mount provided by
Phonon to further improve compensation if single axis
compensation proves inadequate.
• Design analog filter according to digital model to provide final
compensation.
• Test analog filter to see if compensation is in the range of 20db
• Assemble conclusive thesis for final presentation.
![Page 31: VCSO Mechanical Shock Compensation•Measure Instantaneous Frequency shifts and ... erroneous vibration •Resonance •Loose parts . Signal Generator •Giga-tronics 6060B •10kHz-1.05GHz](https://reader034.fdocuments.us/reader034/viewer/2022042201/5ea1bd505ea9de4e86578800/html5/thumbnails/31.jpg)
Timeline
Budget: All Equipment Provided through Phonon