VCFlex10SA2008-stuB.pptx
Transcript of VCFlex10SA2008-stuB.pptx
© 2008 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice
Chris ScarvellAndy LenStu Bernstein
Solutions Academy 2008Virtual Connect
Agenda• Virtual Connect overview (10 minutes)• Virtual Connect new features with 1.3x
firmware−Lab – Multi Enclosure Support (20 minutes)−Lab – Mapped and Tunnelled VLANs (15 minutes)−Lab – Private Networks (15 minutes)
• Virtual Connect Myths and Objections (1 hour)
• BL495c G5 and Virtual Connect FLEX10 (1 hour incl DEMO)
Introducing theHP ProLiant BL495cvirtualization blade
2x more memory thanDell M605 or IBM LS2116 slots, 128 Gb memory
2 solid state drives1st for an HP server bladeOne Watt of power; Ultra fast
2 AMD Quad-CoreDual Dynamic Power ManagementEnhanced AMD-V™ acceleration for virtual environments
Introducing the HP ProLiant BL495c virtualization blade
8 network connections Built-in LOM and 2 expansion slots; 2 more Ethernet NICs than Dell and IBM
Built from the ground up to eliminate bottlenecks to virtual server performance
HP ProLiant 400 series server blades Versatile, concentrated compute power
Model BL460c BL465c BL480c BL495c G5
Processors Dual- or Quad-Core Intel Xeon 5000
Dual- or Quad-Core AMD Opteron 2000
Dual- or Quad-Core Intel Xeon 5000
Quad-Core AMD Opteron 2000
Memory 32GB / 8 DIMMsFB DDR2 667MHz
64GB / 8 DIMMsReg DDR2 667MHz
48GB / 12 DIMMsFB DDR2667MHz
64GB / 16 DIMMsReg DDR2 667MHz
Management iLO 2 Standard Blade Edition
iLO 2 Standard Blade Edition
iLO 2 Standard Blade Edition
iLO 2 Standard Blade Edition
Internal HP Storage
(2) SFF SAS/SATA bays
(2) SFF SAS/SATA bays
(4) SFF SAS/SATA bays (2) SSD bays
RAID RAID 0/1 controller w/ BBWC option
RAID 0/1 controller w/ BBWC option
RAID 0/1/5 controller w/ BBWC option Software RAID
Network Adapters (2) MFN 1GbE (2) MFN 1GbE
(2) MFN 1GbE
(2) Standard 1GbE(2) MFN 10GbE
Mezzanine slots 2 2 3 2
HP ProLiant BL495c G5BL495c G5
Processor Up to two Quad-Core AMD Opteron™ 2300 Series processors
Memory• PC2-5300 Registered DDR2 (667
MHz)• 16 DIMM Sockets• 128GB max (with 8GB DIMMs)
Internal Storage
• 2 NHP SATA SSD• No spinning media
Networking 2 integrated Multifunction 10Gb NICsAdditional NICs via mezzanine card
Mezzanine Slots 2 PCIe mezzanine expansion slots
Management Integrated Lights Out 2 Standard Blade Edition
Density 16 server blades in 10U enclosure8 server blades in 6U enclosure
2 CPUsDDR2 667MHz
HP ProLiant BL495c G5
16 DIMM SlotsDDR2 667MHz
Internal View
Optional SATA SSDs Two Mezzanine Slots• One x4• One x8
Embedded 10Gb EthernetMulti-Function Dual Port NICs
© 2008 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice
In November, BL495c leaps forward with HP Virtual ConnectFlex-10 technology
9 Oct 2008 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential
10Gb Ethernet should be more than a single fat pipe.
10
Oct 2008 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential
• How many NICs would you like on your server today? What speed? Would you like iSCSI with that?
How many NICs would you like on
your Server today?
11
Oct 2008 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential
• How many NICs would you like on your server today? What speed? Would you like iSCSI with that?
…and at whatspeed would you like them to run?
HP Product Announcement – HP Restricted12
What is announcing1 2 3 4 5 6
789101. Module locator UUID2. Module status indicator3. 10Gb X4 backlit port
number and status indicator
4. 10Gb CX4 link indicator5. Link indicator6. Link indicator7. Active multiplexed port
indicator8. Backlit port number and
status indicator LED9. Backlit port number and
status indicator LED10.Active multiplexed port
indicator
HP Product Announcement – HP Restricted12
HP VC Flex-10 10Gb Ethernet Module on HP.com: http://h18004.www1.hp.com/products/blades/components/c-class-interconnects.html
HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem• Single-wide 10Gb Ethernet module
enabling the use of up to four FlexNICs per 10Gb server connection and control of bandwidth by setting NIC speeds from 100Mb to 10Gb
Key new features or capabilities• Single-wide blade 10:10Gb Ethernet
module• Supports Flex-10 enabled 10Gb NICs
− Enables division of single network port into four connections with full hardware performance
− Allows fine tuning of connection bandwidth
• Reduces Mezz & Modules needed by 75%
• Supports up to 24 network connections on a single server blade (with mezz cards)
More info on consolidating networks 4 to 1
HP Product Announcement – HP Restricted13
Faceplate View
Item Description1 1x 10GBASE CX4 Ethernet or 1x SFP+ module (X1)2 Part number and status indicators3 5x SFP+ modules (X2-6) (1GbE or 10 GbE)4 2x crosslinks (midplane) or 2X SFP+ module (X7-8)5 Recessed module reset button
1 2 3 4 5
Midplane: 16x 10GBASE-KR Ethernet - connects to one (1Gb or 10Gb) NIC in each half-height blade bay2x 10Gb Ethernet - Crosslink between adjacent Virtual Connect Ethernet modulesManagement interfaces to Onboard Administrator
HP Product Announcement – HP Restricted14
Introducing the next Virtual Connect breakthroughVirtual Connect Flex-10 technology• 4X more I/O connections per server
− Dual-channel 10Gb Flex-10 NIC onboard delivers 8 FlexNICs on the motherboard
− 24 FlexNIC connections per server via expansion slots− 100% hardware-level performance− User-adjustable bandwidth from 100Mb to 10Gb
for each FlexNIC• Virtual Connect Flex-10 technology
− Delivered in the Virtual Connect Flex-10 module− VC Flex-10 reduces cables and simplifies NIC creation, allocation and management
• Save money at every turn− Lowest cost solution for 4 or more NICs− Lowest power consumption for 6 or more NIC – up to
270w savings per enclosureHP Virtual Connect Flex-10Ethernet module
Traditional blade servers need too many modules & mezz cards!
DualLOM
QuadNIC
8Interconnect Modules
Net 2 Net 3 Net 4Net 1
4Redundant networks
8NICs requireQuadNIC
DualNIC 2Mezz cards
VC Flex-10 drops Mezz & Modules by 75%!
8 2Interconnect Modules
Net 2 Net 3 Net 4Net 1
4Redundant networks
8NICs require2 0Mezz cardsDual Flex-10
Controller
HP Product Announcement – HP Restricted17
Expandable to 4x more NIC connections than any other server blade
NICconnections
Up toVirtualConnectFlex-10
VirtualConnectFlex-10
VirtualConnectFlex-10
Built-in LOM
Optional Mezz Card
Optional Mezz Card
Easy and cost effective to add more NICs to support more virtual servers ( )
HP Product Announcement – HP Restricted18
First ever to provide precise control over bandwidth per NIC connection
Fine-tune the speed of each network connection
So you can set and prioritize performance for each VM channel
In 100Mb increments from 100Mb to 10Gb( )
VirtualConnectFlex-10
VirtualConnectFlex-10
Flex-10 delivers the most flexibility to configure VM channel performance
ProductionNIC #1
VmotionNIC #2
ConsoleNIC #3
BackupNIC #4
Traditional 1Gb
technology1Gb 1Gb 1Gb 1Gb
Virtual Connect Flex-10
2Gb 2.9Gb 100Mb 5Gb
Optimize & prioritize performance per channel based on your business priorities
NDA
HP Product Announcement – HP Restricted20
One network configuration consolidates your network regardless of the number NICs/server
2 NICs
4 NICs
6 NICs
8 NICs
Simplify
the number of network configurations
Flex-10 for Virtual ConnectEach Flex-10 LOM has two 10Gb physical ports
21 Oct 2008 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential
Port 1
FlexNIC
10Gb VC-EnetModule (Odd)
ServerBlade
Single lane of 10Gb/s Ethernet
for each Port
FlexNIC FlexNIC FlexNIC
Port 2
FlexNIC FlexNIC FlexNIC FlexNIC
Flex-10 LOM or Mezz Card
10Gb VC-EnetModule (Even)
Goes to separateinterconnect bays(Odd, Even)
HP Restricted
10Gb-XAUI versus 10Gb-KRNumber of lanes enables first 10Gb single-wide interconnect
Single-wide Interconnect
2 TX pairs, 2 RX pairs
Double-wide Interconnect
2 TX pairs, 2 RX pairs
1 TX pair, 1 RX pair
HP Restricted
Oct 200822 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential
Flex-10 for Virtual ConnectEach Flex-10 port has 4 PCI functions
23 Oct 2008 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential
Port 1
PF 1
10Gb VC-EnetModule (Odd)
ServerBlade
OS discovers 4 PCI functions per Flex-10 physical port
PF 2 PF 3 PF 4
Port 2
PF 1 PF 2 PF 3 PF 4
Flex-10 LOM or Mezz Card
HP Restricted
Flex-10 in Windows Server 2008
24 Oct 2008
HP Restricted
Flex-10 in ESX 3.5 U3
25 Oct 2008
HP Restricted
Flex-10 for Virtual ConnectVirtual Connect configures Flex-10 prior to boot
26 Oct 2008 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential
Port 1
PF 1
10Gb VC-EnetModule (Odd)
ServerBlade
VC configures 4 FlexNICs per port
PF 2 PF 3 PF 4
Port 2
PF 1 PF 2 PF 3 PF 4
Flex-10 LOM or Mezz Card
For each NIC (FlexNIC), VC sets: -- bandwidth (0.1 to 10Gb/s) -- link state -- MAC address
HP Restricted
Flex-10 for Virtual ConnectConfigure network connectivity anytime
27 Oct 2008 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential
10Gb VC-EnetModule (Odd)
ServerBlade
For each NIC (FlexNIC), VC sets: -- bandwidth (0.1 to 10Gb/s) -- link state -- MAC address -- vNet connection
Port 1
FlexNIC FlexNIC FlexNIC FlexNIC
Port 2
FlexNIC FlexNIC FlexNIC FlexNIC
Flex-10 LOM or Mezz Card
HP Restricted
Flex-10 for Virtual ConnectMap Flex-10 NICs to any vNet
28 Oct 2008 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential
Port 2ServerBlade
For each NIC (PF), VC sets: -- bandwidth (0.1 to 10 Gb/s) -- MAC address -- vNet connection
Port 1Flex-10 LOM or Mezz Card
vNet 2 vNet 3 vNet 4vNet 1
10Gb VC-Enet Module
FlexNIC FlexNIC FlexNIC FlexNIC FlexNIC FlexNIC FlexNIC FlexNIC
HP Restricted
Flex-10 for Virtual ConnectFlex-10 and 10Gb VC-Enet keep traffic separated
29 Oct 2008 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential
ServerBlade
Flex-10 and VC-Enet module keep the traffic separated and on the correct network.
Flex-10 LOM or Mezz CardPort 1
vNet 2 vNet 3 vNet 4vNet 1
Flex-10 limits traffic per flexNIC (physical function)
10Gb VC-Enet Module
FlexNIC FlexNIC FlexNIC FlexNIC
HP Restricted
Why buy Flex-10?
Let’s look at a real world example …
Blade InterconnectsHypervisor HostTe
amTe
amTe
amTe
am
Why do customers want Flex-10?Anatomy of a typical hypervisor host
31 Oct 2008
PROD-A
PROD-B
CONSOLE
MOTION
HP Restricted
LOM
MEZ1
MEZ2
© 2008 Hewlett-Packard Development Company, L.P. HP Confidential
c7000 Half-height servers to interconnect baysc-Class Server Blades c-Class Interconnect Bays
Blade9
Blade1 NIC1
Mezz1
Mezz2
Mezz2
1/2
3/4
5/6
7/8
1/2
3/4
5/6
7/8
1
2
NIC1NIC2
Mezz1
1234
1
2
NIC2
1234
3 4
7
1
5
8
6
2
Oct 200832 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential
Blade InterconnectsHypervisor HostTe
amTe
amTe
amTe
am
Why do customers want Flex-10? Anatomy of a typical hypervisor host
33 Oct 2008
PROD-A
PROD-B
CONSOLE
HP Restricted
7 8
1 2
3 4
5 6MOTION
LOM
MEZ1
MEZ2
© 2008 Hewlett-Packard Development Company, L.P. HP Confidential
Blade InterconnectsHypervisor HostTe
amTe
amTe
amTe
am
Why do customers want Flex-10?Flex-10 saves you money!
34 Oct 2008
PROD-A
PROD-B
CONSOLE
HP Restricted
LOM
7 8
1 2
3 4
5 6
FlexNICFlexNIC
FlexNICFlexNIC
FlexNICFlexNIC
FlexNICFlexNIC
1 2
MOTION
4Gb
4Gb
100Mb
1.8Gb
© 2008 Hewlett-Packard Development Company, L.P. HP Confidential
HP Product Announcement – HP Restricted35
HP VC Flex-10 10Gb Ethernet module innovations−First extension of the award-
winning HP Virtual Connect architecture
−First to divide a single NIC port into four separate FlexNIC connections at full hardware performance
−First to tune each FlexNIC connection bandwidth to the needs of virtual server workloads from 100Mb to 10Gb
−First to provide 8 FlexNIC connections standard on a blade server without needing two more NIC mezz cards and 6 more switch modules
−First to support up to 24 network connections on a single server blade – 4x the competition
Removes I/O bottlenecks to host more VMs per blade at lower cost while consolidating the network
HP Product Announcement – HP Restricted36
Why Virtual Connect is vital to you!Virtual Connect is foundational•Foundation for:•HP’s (and your) future data center transformation business and HP virtualization strategy – no VC means no AI•Insight Dynamics – VSE, managing physical and logical servers (no VC and ID doesn’t work and you don’t sell it)•HP BTO software•Stopping Cisco from taking your sales and margin
Losing the Virtual Connect business puts all the above at risk
HP Product Announcement – HP Restricted37
Virtual Connect Flex-10
Virtual Connect 1/10Gb-F
Virtual Connect 1/10Gb
Best for Virtual Servers and network consolidation
Mainstream high performance BladeSystem interconnect
Lowest cost, entry level Virtual Connect module
Network Connections
• 16 x 10Gb downlinks midplane
• 2 x 10Gb cross connect• 1 x 10Gb copper uplinks
CX-4• 8 x 10Gb SR, LR, or LRM
fiber uplinks SFP+• 1 management USB port• 1 internal interface to c-
Class Onboard Administrator Module
• 16 x 1Gb downlinks midplane
• 1 x 10Gb cross connect• 1 x 10Gb copper uplinks
CX-4• 2 x 10Gb SR or LR fiber
uplinks XFP• 2 x 1Gb SX or RJ-45 fiber
uplinks SFP• 4 x 1Gb 1000/100/10Gb
copper uplinks RJ-45• 1 management USB port• 1 internal interface to c-
Class Onboard Administrator Module
• 16 x 1Gb downlinks midplane
• 1 x 10Gb cross connect• 2 x 10Gb copper uplinks
CX-4• 8 x 1Gb 1000/100/10Gb
copper uplinks RJ-45 • 1 management USB port• 1 internal interface to c-
Class Onboard Administrator Module
Performance
• Line rate, full-duplex 240Gbps bridging fabric
• Less than 1ms latency
• Line rate, full-duplex 62 Gbp/s bridging fabric
• Less than 4ms latency
• Line rate, full-duplex 54 Gbp/s bridging fabric
• Less than 4ms latencyProtocols 802.1AB, 802.1D, 802.1Q, IEEE 802.2, 802.3adManagement
• Intuitive graphical user interface and setup wizards • Embedded SNMP v1, v2 • Command Line Interface • Any uplink port can be used as a dedicated mirrored port from the server port(s)
Security • LDAP, SSL, Role-based management
VC 1.xx VC 2.xxSupported modules 1/10Gb VC-Enet (1Gb down)
1/10Gb-F VC-Enet (1Gb down)1/10Gb VC-Enet (1Gb down)1/10Gb-F VC-Enet (1Gb down)Flex-10 10Gb VC-Enet
Flex-10 capability FlexNICs enumerated when connected to VC-Enet with 1Gb down
2 2
FlexNICs enumerated when connected to VC-Enet with 10Gb down
Not Supported 8
Virtual Connect capability matrix
38 Oct 2008 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential
Linked at 1Gb
Some PFs might not be linked
HP Restricted
© 2008 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice
DEMO
© 2008 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice
Thanks