VCFlex10SA2008-stuB.pptx

40
© 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice Chris Scarvell Andy Len Stu Bernstein Solutions Academy 2008 Virtual Connect

Transcript of VCFlex10SA2008-stuB.pptx

Page 1: VCFlex10SA2008-stuB.pptx

© 2008 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice

Chris ScarvellAndy LenStu Bernstein

Solutions Academy 2008Virtual Connect

Page 2: VCFlex10SA2008-stuB.pptx

Agenda• Virtual Connect overview (10 minutes)• Virtual Connect new features with 1.3x

firmware−Lab – Multi Enclosure Support (20 minutes)−Lab – Mapped and Tunnelled VLANs (15 minutes)−Lab – Private Networks (15 minutes)

• Virtual Connect Myths and Objections (1 hour)

• BL495c G5 and Virtual Connect FLEX10 (1 hour incl DEMO)

Page 3: VCFlex10SA2008-stuB.pptx

Introducing theHP ProLiant BL495cvirtualization blade

Page 4: VCFlex10SA2008-stuB.pptx

2x more memory thanDell M605 or IBM LS2116 slots, 128 Gb memory

2 solid state drives1st for an HP server bladeOne Watt of power; Ultra fast

2 AMD Quad-CoreDual Dynamic Power ManagementEnhanced AMD-V™ acceleration for virtual environments

Introducing the HP ProLiant BL495c virtualization blade

8 network connections Built-in LOM and 2 expansion slots; 2 more Ethernet NICs than Dell and IBM

Built from the ground up to eliminate bottlenecks to virtual server performance

Page 5: VCFlex10SA2008-stuB.pptx

HP ProLiant 400 series server blades Versatile, concentrated compute power

Model BL460c BL465c BL480c BL495c G5

Processors Dual- or Quad-Core Intel Xeon 5000

Dual- or Quad-Core AMD Opteron 2000

Dual- or Quad-Core Intel Xeon 5000

Quad-Core AMD Opteron 2000

Memory 32GB / 8 DIMMsFB DDR2 667MHz

64GB / 8 DIMMsReg DDR2 667MHz

48GB / 12 DIMMsFB DDR2667MHz

64GB / 16 DIMMsReg DDR2 667MHz

Management iLO 2 Standard Blade Edition

iLO 2 Standard Blade Edition

iLO 2 Standard Blade Edition

iLO 2 Standard Blade Edition

Internal HP Storage

(2) SFF SAS/SATA bays

(2) SFF SAS/SATA bays

(4) SFF SAS/SATA bays (2) SSD bays

RAID RAID 0/1 controller w/ BBWC option

RAID 0/1 controller w/ BBWC option

RAID 0/1/5 controller w/ BBWC option Software RAID

Network Adapters (2) MFN 1GbE (2) MFN 1GbE

(2) MFN 1GbE

(2) Standard 1GbE(2) MFN 10GbE

Mezzanine slots 2 2 3 2

Page 6: VCFlex10SA2008-stuB.pptx

HP ProLiant BL495c G5BL495c G5

Processor Up to two Quad-Core AMD Opteron™ 2300 Series processors

Memory• PC2-5300 Registered DDR2 (667

MHz)• 16 DIMM Sockets• 128GB max (with 8GB DIMMs)

Internal Storage

• 2 NHP SATA SSD• No spinning media

Networking 2 integrated Multifunction 10Gb NICsAdditional NICs via mezzanine card

Mezzanine Slots 2 PCIe mezzanine expansion slots

Management Integrated Lights Out 2 Standard Blade Edition

Density 16 server blades in 10U enclosure8 server blades in 6U enclosure

Page 7: VCFlex10SA2008-stuB.pptx

2 CPUsDDR2 667MHz

HP ProLiant BL495c G5

16 DIMM SlotsDDR2 667MHz

Internal View

Optional SATA SSDs Two Mezzanine Slots• One x4• One x8

Embedded 10Gb EthernetMulti-Function Dual Port NICs

Page 8: VCFlex10SA2008-stuB.pptx

© 2008 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice

In November, BL495c leaps forward with HP Virtual ConnectFlex-10 technology

Page 9: VCFlex10SA2008-stuB.pptx

9 Oct 2008 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential

10Gb Ethernet should be more than a single fat pipe.

Page 10: VCFlex10SA2008-stuB.pptx

10

Oct 2008 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential

• How many NICs would you like on your server today? What speed? Would you like iSCSI with that?

How many NICs would you like on

your Server today?

Page 11: VCFlex10SA2008-stuB.pptx

11

Oct 2008 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential

• How many NICs would you like on your server today? What speed? Would you like iSCSI with that?

…and at whatspeed would you like them to run?

Page 12: VCFlex10SA2008-stuB.pptx

HP Product Announcement – HP Restricted12

What is announcing1 2 3 4 5 6

789101. Module locator UUID2. Module status indicator3. 10Gb X4 backlit port

number and status indicator

4. 10Gb CX4 link indicator5. Link indicator6. Link indicator7. Active multiplexed port

indicator8. Backlit port number and

status indicator LED9. Backlit port number and

status indicator LED10.Active multiplexed port

indicator

HP Product Announcement – HP Restricted12

HP VC Flex-10 10Gb Ethernet Module on HP.com: http://h18004.www1.hp.com/products/blades/components/c-class-interconnects.html

HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem• Single-wide 10Gb Ethernet module

enabling the use of up to four FlexNICs per 10Gb server connection and control of bandwidth by setting NIC speeds from 100Mb to 10Gb

Key new features or capabilities• Single-wide blade 10:10Gb Ethernet

module• Supports Flex-10 enabled 10Gb NICs

− Enables division of single network port into four connections with full hardware performance

− Allows fine tuning of connection bandwidth

• Reduces Mezz & Modules needed by 75%

• Supports up to 24 network connections on a single server blade (with mezz cards)

More info on consolidating networks 4 to 1

Page 13: VCFlex10SA2008-stuB.pptx

HP Product Announcement – HP Restricted13

Faceplate View

Item Description1 1x 10GBASE CX4 Ethernet or 1x SFP+ module (X1)2 Part number and status indicators3 5x SFP+ modules (X2-6) (1GbE or 10 GbE)4 2x crosslinks (midplane) or 2X SFP+ module (X7-8)5 Recessed module reset button

1 2 3 4 5

Midplane: 16x 10GBASE-KR Ethernet - connects to one (1Gb or 10Gb) NIC in each half-height blade bay2x 10Gb Ethernet - Crosslink between adjacent Virtual Connect Ethernet modulesManagement interfaces to Onboard Administrator

Page 14: VCFlex10SA2008-stuB.pptx

HP Product Announcement – HP Restricted14

Introducing the next Virtual Connect breakthroughVirtual Connect Flex-10 technology• 4X more I/O connections per server

− Dual-channel 10Gb Flex-10 NIC onboard delivers 8 FlexNICs on the motherboard

− 24 FlexNIC connections per server via expansion slots− 100% hardware-level performance− User-adjustable bandwidth from 100Mb to 10Gb

for each FlexNIC• Virtual Connect Flex-10 technology

− Delivered in the Virtual Connect Flex-10 module− VC Flex-10 reduces cables and simplifies NIC creation, allocation and management

• Save money at every turn− Lowest cost solution for 4 or more NICs− Lowest power consumption for 6 or more NIC – up to

270w savings per enclosureHP Virtual Connect Flex-10Ethernet module

Page 15: VCFlex10SA2008-stuB.pptx

Traditional blade servers need too many modules & mezz cards!

DualLOM

QuadNIC

8Interconnect Modules

Net 2 Net 3 Net 4Net 1

4Redundant networks

8NICs requireQuadNIC

DualNIC 2Mezz cards

Page 16: VCFlex10SA2008-stuB.pptx

VC Flex-10 drops Mezz & Modules by 75%!

8 2Interconnect Modules

Net 2 Net 3 Net 4Net 1

4Redundant networks

8NICs require2 0Mezz cardsDual Flex-10

Controller

Page 17: VCFlex10SA2008-stuB.pptx

HP Product Announcement – HP Restricted17

Expandable to 4x more NIC connections than any other server blade

NICconnections

Up toVirtualConnectFlex-10

VirtualConnectFlex-10

VirtualConnectFlex-10

Built-in LOM

Optional Mezz Card

Optional Mezz Card

Easy and cost effective to add more NICs to support more virtual servers ( )

Page 18: VCFlex10SA2008-stuB.pptx

HP Product Announcement – HP Restricted18

First ever to provide precise control over bandwidth per NIC connection

Fine-tune the speed of each network connection

So you can set and prioritize performance for each VM channel

In 100Mb increments from 100Mb to 10Gb( )

VirtualConnectFlex-10

VirtualConnectFlex-10

Page 19: VCFlex10SA2008-stuB.pptx

Flex-10 delivers the most flexibility to configure VM channel performance

ProductionNIC #1

VmotionNIC #2

ConsoleNIC #3

BackupNIC #4

Traditional 1Gb

technology1Gb 1Gb 1Gb 1Gb

Virtual Connect Flex-10

2Gb 2.9Gb 100Mb 5Gb

Optimize & prioritize performance per channel based on your business priorities

NDA

Page 20: VCFlex10SA2008-stuB.pptx

HP Product Announcement – HP Restricted20

One network configuration consolidates your network regardless of the number NICs/server

2 NICs

4 NICs

6 NICs

8 NICs

Simplify

the number of network configurations

Page 21: VCFlex10SA2008-stuB.pptx

Flex-10 for Virtual ConnectEach Flex-10 LOM has two 10Gb physical ports

21 Oct 2008 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential

Port 1

FlexNIC

10Gb VC-EnetModule (Odd)

ServerBlade

Single lane of 10Gb/s Ethernet

for each Port

FlexNIC FlexNIC FlexNIC

Port 2

FlexNIC FlexNIC FlexNIC FlexNIC

Flex-10 LOM or Mezz Card

10Gb VC-EnetModule (Even)

Goes to separateinterconnect bays(Odd, Even)

HP Restricted

Page 22: VCFlex10SA2008-stuB.pptx

10Gb-XAUI versus 10Gb-KRNumber of lanes enables first 10Gb single-wide interconnect

Single-wide Interconnect

2 TX pairs, 2 RX pairs

Double-wide Interconnect

2 TX pairs, 2 RX pairs

1 TX pair, 1 RX pair

HP Restricted

Oct 200822 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential

Page 23: VCFlex10SA2008-stuB.pptx

Flex-10 for Virtual ConnectEach Flex-10 port has 4 PCI functions

23 Oct 2008 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential

Port 1

PF 1

10Gb VC-EnetModule (Odd)

ServerBlade

OS discovers 4 PCI functions per Flex-10 physical port

PF 2 PF 3 PF 4

Port 2

PF 1 PF 2 PF 3 PF 4

Flex-10 LOM or Mezz Card

HP Restricted

Page 24: VCFlex10SA2008-stuB.pptx

Flex-10 in Windows Server 2008

24 Oct 2008

HP Restricted

Page 25: VCFlex10SA2008-stuB.pptx

Flex-10 in ESX 3.5 U3

25 Oct 2008

HP Restricted

Page 26: VCFlex10SA2008-stuB.pptx

Flex-10 for Virtual ConnectVirtual Connect configures Flex-10 prior to boot

26 Oct 2008 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential

Port 1

PF 1

10Gb VC-EnetModule (Odd)

ServerBlade

VC configures 4 FlexNICs per port

PF 2 PF 3 PF 4

Port 2

PF 1 PF 2 PF 3 PF 4

Flex-10 LOM or Mezz Card

For each NIC (FlexNIC), VC sets: -- bandwidth (0.1 to 10Gb/s) -- link state -- MAC address

HP Restricted

Page 27: VCFlex10SA2008-stuB.pptx

Flex-10 for Virtual ConnectConfigure network connectivity anytime

27 Oct 2008 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential

10Gb VC-EnetModule (Odd)

ServerBlade

For each NIC (FlexNIC), VC sets: -- bandwidth (0.1 to 10Gb/s) -- link state -- MAC address -- vNet connection

Port 1

FlexNIC FlexNIC FlexNIC FlexNIC

Port 2

FlexNIC FlexNIC FlexNIC FlexNIC

Flex-10 LOM or Mezz Card

HP Restricted

Page 28: VCFlex10SA2008-stuB.pptx

Flex-10 for Virtual ConnectMap Flex-10 NICs to any vNet

28 Oct 2008 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential

Port 2ServerBlade

For each NIC (PF), VC sets: -- bandwidth (0.1 to 10 Gb/s) -- MAC address -- vNet connection

Port 1Flex-10 LOM or Mezz Card

vNet 2 vNet 3 vNet 4vNet 1

10Gb VC-Enet Module

FlexNIC FlexNIC FlexNIC FlexNIC FlexNIC FlexNIC FlexNIC FlexNIC

HP Restricted

Page 29: VCFlex10SA2008-stuB.pptx

Flex-10 for Virtual ConnectFlex-10 and 10Gb VC-Enet keep traffic separated

29 Oct 2008 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential

ServerBlade

Flex-10 and VC-Enet module keep the traffic separated and on the correct network.

Flex-10 LOM or Mezz CardPort 1

vNet 2 vNet 3 vNet 4vNet 1

Flex-10 limits traffic per flexNIC (physical function)

10Gb VC-Enet Module

FlexNIC FlexNIC FlexNIC FlexNIC

HP Restricted

Page 30: VCFlex10SA2008-stuB.pptx

Why buy Flex-10?

Let’s look at a real world example …

Page 31: VCFlex10SA2008-stuB.pptx

Blade InterconnectsHypervisor HostTe

amTe

amTe

amTe

am

Why do customers want Flex-10?Anatomy of a typical hypervisor host

31 Oct 2008

PROD-A

PROD-B

CONSOLE

MOTION

HP Restricted

LOM

MEZ1

MEZ2

© 2008 Hewlett-Packard Development Company, L.P. HP Confidential

Page 32: VCFlex10SA2008-stuB.pptx

c7000 Half-height servers to interconnect baysc-Class Server Blades c-Class Interconnect Bays

Blade9

Blade1 NIC1

Mezz1

Mezz2

Mezz2

1/2

3/4

5/6

7/8

1/2

3/4

5/6

7/8

1

2

NIC1NIC2

Mezz1

1234

1

2

NIC2

1234

3 4

7

1

5

8

6

2

Oct 200832 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential

Page 33: VCFlex10SA2008-stuB.pptx

Blade InterconnectsHypervisor HostTe

amTe

amTe

amTe

am

Why do customers want Flex-10? Anatomy of a typical hypervisor host

33 Oct 2008

PROD-A

PROD-B

CONSOLE

HP Restricted

7 8

1 2

3 4

5 6MOTION

LOM

MEZ1

MEZ2

© 2008 Hewlett-Packard Development Company, L.P. HP Confidential

Page 34: VCFlex10SA2008-stuB.pptx

Blade InterconnectsHypervisor HostTe

amTe

amTe

amTe

am

Why do customers want Flex-10?Flex-10 saves you money!

34 Oct 2008

PROD-A

PROD-B

CONSOLE

HP Restricted

LOM

7 8

1 2

3 4

5 6

FlexNICFlexNIC

FlexNICFlexNIC

FlexNICFlexNIC

FlexNICFlexNIC

1 2

MOTION

4Gb

4Gb

100Mb

1.8Gb

© 2008 Hewlett-Packard Development Company, L.P. HP Confidential

Page 35: VCFlex10SA2008-stuB.pptx

HP Product Announcement – HP Restricted35

HP VC Flex-10 10Gb Ethernet module innovations−First extension of the award-

winning HP Virtual Connect architecture

−First to divide a single NIC port into four separate FlexNIC connections at full hardware performance

−First to tune each FlexNIC connection bandwidth to the needs of virtual server workloads from 100Mb to 10Gb

−First to provide 8 FlexNIC connections standard on a blade server without needing two more NIC mezz cards and 6 more switch modules

−First to support up to 24 network connections on a single server blade – 4x the competition

Removes I/O bottlenecks to host more VMs per blade at lower cost while consolidating the network

Page 36: VCFlex10SA2008-stuB.pptx

HP Product Announcement – HP Restricted36

Why Virtual Connect is vital to you!Virtual Connect is foundational•Foundation for:•HP’s (and your) future data center transformation business and HP virtualization strategy – no VC means no AI•Insight Dynamics – VSE, managing physical and logical servers (no VC and ID doesn’t work and you don’t sell it)•HP BTO software•Stopping Cisco from taking your sales and margin

Losing the Virtual Connect business puts all the above at risk

Page 37: VCFlex10SA2008-stuB.pptx

HP Product Announcement – HP Restricted37

Virtual Connect Flex-10

Virtual Connect 1/10Gb-F

Virtual Connect 1/10Gb

Best for Virtual Servers and network consolidation

Mainstream high performance BladeSystem interconnect

Lowest cost, entry level Virtual Connect module

Network Connections

• 16 x 10Gb downlinks midplane

• 2 x 10Gb cross connect• 1 x 10Gb copper uplinks

CX-4• 8 x 10Gb SR, LR, or LRM

fiber uplinks SFP+• 1 management USB port• 1 internal interface to c-

Class Onboard Administrator Module

• 16 x 1Gb downlinks midplane

• 1 x 10Gb cross connect• 1 x 10Gb copper uplinks

CX-4• 2 x 10Gb SR or LR fiber

uplinks XFP• 2 x 1Gb SX or RJ-45 fiber

uplinks SFP• 4 x 1Gb 1000/100/10Gb

copper uplinks RJ-45• 1 management USB port• 1 internal interface to c-

Class Onboard Administrator Module

• 16 x 1Gb downlinks midplane

• 1 x 10Gb cross connect• 2 x 10Gb copper uplinks

CX-4• 8 x 1Gb 1000/100/10Gb

copper uplinks RJ-45 • 1 management USB port• 1 internal interface to c-

Class Onboard Administrator Module

Performance

• Line rate, full-duplex 240Gbps bridging fabric

• Less than 1ms latency

• Line rate, full-duplex 62 Gbp/s bridging fabric

• Less than 4ms latency

• Line rate, full-duplex 54 Gbp/s bridging fabric

• Less than 4ms latencyProtocols 802.1AB, 802.1D, 802.1Q, IEEE 802.2, 802.3adManagement

• Intuitive graphical user interface and setup wizards • Embedded SNMP v1, v2 • Command Line Interface • Any uplink port can be used as a dedicated mirrored port from the server port(s)

Security • LDAP, SSL, Role-based management

Page 38: VCFlex10SA2008-stuB.pptx

VC 1.xx VC 2.xxSupported modules 1/10Gb VC-Enet (1Gb down)

1/10Gb-F VC-Enet (1Gb down)1/10Gb VC-Enet (1Gb down)1/10Gb-F VC-Enet (1Gb down)Flex-10 10Gb VC-Enet

Flex-10 capability FlexNICs enumerated when connected to VC-Enet with 1Gb down

2 2

FlexNICs enumerated when connected to VC-Enet with 10Gb down

Not Supported 8

Virtual Connect capability matrix

38 Oct 2008 © 2008 Hewlett-Packard Development Company, L.P. HP Confidential

Linked at 1Gb

Some PFs might not be linked

HP Restricted

Page 39: VCFlex10SA2008-stuB.pptx

© 2008 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice

DEMO

Page 40: VCFlex10SA2008-stuB.pptx

© 2008 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice

Thanks