Varixx Temperatura

52
Z Y G G O T MANUAL Manual_Zyggot_Temp_Tube_V6P Versão para redes cabeadas e relés VZX / VZT versão 6P ZYGGOT TEMPERATURA SISTEMA DE MONITORAMENTO E PROTEÇÃO DE TEMPERATURA SEM CONTATO MODELO: SENSOR TUBULAR Zyggot é Marca Registrada da Varixx Varixx e seu logo são marcas registradas Outras marcas são registradas por seus respectivos proprietários

description

Varixx Temperatura

Transcript of Varixx Temperatura

  • Z Y G G O T

    MANUAL

    Manual_Zyggot_Temp_Tube_V6P

    Verso para redes cabeadase rels VZX / VZT

    verso 6P

    ZYGGOT TEMPERATURASISTEMA DE MONITORAMENTO E PROTEO DE TEMPERATURA SEM CONTATO

    MODELO: SENSOR TUBULAR

    Zyggot Marca Registrada da VarixxVarixx e seu logo so marcas registradasOutras marcas so registradas por seus respectivos proprietrios

  • BLANK

  • DESCRIO ..................................................................................................................................................................4CAPTAO DA MEDIDA DE TEMPERATURA E INFLUNCIA DA EMISSIVIDADE NA MEDIO .........................5 FITA UNIDEX .........................................................................................................................................................................5 POSICIONAMENTO DOS SENSORES E LEITURA DA TEMPERATURA ............................................................................6 NGULO DE VISADA ............................................................................................................................................................6 FIXAO DOS SENSORES .................................................................................................................................................6 SUPORTE...............................................................................................................................................................................6 REL .....................................................................................................................................................................................6COMPOSIO DO PRODUTO .....................................................................................................................................7 FONTE DE ALIMENTAO ............................................................................................................................7 DERIVADOR ZTA ............................................................................................................................................7 CABO MINI USB .............................................................................................................................................7 MALETA DE INSTALAO E MANUTENO ..............................................................................................7 MIRA LASER ...................................................................................................................................................7 CABO CONFIGURADOR USB .......................................................................................................................7DIAGRAMA UNIFILAR E CARACTERSTICAS PRINCIPAIS ......................................................................................8ESQUEMA DE LIGAO ..............................................................................................................................................9INSTALAO DO REL E CIRCUITOS DE BAIXA TENSO ...................................................................................12TABELA DE FUNES ...............................................................................................................................................13TESTE DE INTEGRIDADE ..........................................................................................................................................13OVERLAY .....................................................................................................................................................................13ESPECIFICAES TCNICAS ..................................................................................................................................14 Especificaes Gerais .................................................................................................................................14 Caixa de Derivao Traseira .......................................................................................................................14 Especificao Profibus-DP ..........................................................................................................................14 Entradas Digitais ..........................................................................................................................................15 Sadas Digitais ..............................................................................................................................................15 Especificaes Sensores ............................................................................................................................15 Fonte de Alimentao ..................................................................................................................................15ESPECIFICAES TCNICAS MODELO VZX ..........................................................................................................16ESPECIFICAES TCNICAS MODELO VZT ..........................................................................................................17MECNICA MODELOS VZX E VZT ............................................................................................................................18RESUMO DE TELAS ...................................................................................................................................................19RESUMO DE PROGRAMAO E OPERAO ........................................................................................................21FLUXO DE TELAS REL MODELO VZX ...................................................................................................................22FLUXO DE TELAS REL MODELO VZT ...................................................................................................................28PARAMETRIZAO PELO REL ..............................................................................................................................34 SUBMENU CONFIG RELE ..................................................................................................................................................34 SUBMENU CONFIG. PARAM. ............................................................................................................................................34 SUBMENU SENSORES ......................................................................................................................................................34 SUBMENU PROG. BLOCOS ..............................................................................................................................................34 SUBMENU ENTRADAS ANALOGICAS ..............................................................................................................................34 SUBMENU MODBUS ..........................................................................................................................................................34 SUBMENU SENSOR COMMUNICATION ...........................................................................................................................34 SUBMENU NVEIS ALARME PONTOS ..............................................................................................................................34 SUBMENU NVEIS TRIP PONTOS .....................................................................................................................................34 SUBMENU CONFIG TRENDING ........................................................................................................................................34 SUBMENU LIMPA DADOS ..................................................................................................................................................35 SUBMENU PROTEES ...................................................................................................................................................35 SUBMENU PROTEES 1/3 .............................................................................................................................................35 SUBMENU PROTEES 2/3 .............................................................................................................................................36 SUBMENU PROTEES 3/3 .............................................................................................................................................36PARAMETRIZAO PELO COMPUTADOR ..............................................................................................................37CONFIGURAO DO SENSOR .................................................................................................................................38SOFTWARE SUPERVISRIO .....................................................................................................................................40OPERAO .................................................................................................................................................................41COMO FAZER ..............................................................................................................................................................45MAPA DE REGISTROS MODBUS ..............................................................................................................................47MAPA DE REGISTROS PROFIBUS ............................................................................................................................49

    NDICE

    3

    Z Y G G O T

  • 4

    Z Y G G O Tsistema de termografia online sem contato

    DESCRIO

    O ZYGGOT TEMPERATURA um sistema elaborado para monitoramento online de temperatura de componentes e conexes internas de painis de baixa e mdia tenso, transformadores, m o t o r e s , g e r a d o r e s e o u t r o s dispositivos.O sistema introduz uma inovao no mercado: as novas normas de segurana inibem a abertura de painis eltricos energizados para qualquer tipo de medio, inclusive medies de temperatura com pistolas manuais de m e d i o p o n t u a l o u c m e r a s termogrficas. O Sistema ZYGGOT monitora temperaturas sem contato de barramentos e componentes de painis de baixa e mdia tenso sem risco para o operador ou painel.O Sistema composto por pelo menos um rel e um sensor. As informaes das temperaturas medidas por cada sensor so enviadas atravs de uma rede de comunicao ao rel. H a possibilidade de mon i to ra r a t 125 pon tos selecionados (alvos) de temperatura. Para cada alvo, deve-se utilizar um sensor.Os sensores possuem ngulo de abertura de 7, possibilitando monitorar desde reas pontuais at reas de alguns centmetros quadrados. A distncia entre o sensor e o alvo define o tamanho da rea de medio. Uma caracterstica importante do sensor a medio simultnea da temperatura do alvo e do corpo do sensor (que igual a temperatura do ar circundante). Isto permite detectar e levaes de temperatura interna do painel , identificando obstrues, falhas de ventilao ou mesmo elevao de temperatura de pontos no monitorados diretamente.

    O rel tem a funo de realizar a leitura dos valores de temperatura dos sensores e informar ao usurio a temperatura de cada alvo. Seis sadas digitais esto disponveis: uma delas atua quando algum alvo estiver com temperatura superior ao nvel de alarme (alarme 1) e a outra atua quando a temperatura estiver superior ao nvel de trip (alarme 2). As demais sadas so configurveis.Dois mtodos de transmisso de dados entre sensores e rel esto disponveis. Um mtodo utiliza fibras pticas polimricas (conectando um sensor em srie com outro e por ltimo ao rel e do rel ao primeiro sensor formando um anel). Este sistema denominado Zyggot Temperatura Fibra ptica. Para maiores informaes consulte o catlogo do Sistema Zyggot ou o manual do Zyggot Temperatura Fibra pticas. O outro mtodo utiliza comunicao em camada fsica RS-485, com todos os sensores conectados em paralelo uti l izando cabos blindados com conectores mini-USB que permitem rpida instalao e operao. Os sistemas Zyggot Temperatura BT e Zyggot Temperatura Tubular utilizam este mtodo de comunicao. Este manual aborda o sistema Zyggot Temperatura Tubular.O rel do sistema Zyggot Temperatura pode ser conectado a uma rede de comunicao para intercomunicao c o m s i s t e m a s u p e r v i s r i o o u m o n i t o r a m e n t o r e m o t o . E s t o disponveis duas verses de rel: uma com protocolo Modbus RTU e outra com protocolo PROFIBUS-DP.

    SUPERV

    ISRIO

    ZYGGO

    VERSO

    1.O / 2

    008

    Zyggo M

    arca Reg

    istrada d

    a Varixx

    Varixx e

    seu logo

    so mar

    cas regi

    stradas

    Z Y G G O

    T

    INTELL

    IGENT T

    EMPERA

    TURE M

    ONITOR

    ING SYS

    TEM

    SUPERV

    ISRIO

    APLICAO

    Monitoramento de temperatura e proteo online de conexes internas e componentes para painis eltricos de baixa e mdia tenso, transformadores, motores, geradores e outros processos industriais.

    BENEFCIOS

    Medio sem contato.

    Evita abertura do painel energizado.

    Dispensa termografia peridica.

    Fornece leituras de alvo e sensor.

    Indica eventual sensor em falha.

    Histrico de falhas.

    CARACTERSTICAS

    Aplicvel em baixa e mdia tenso.

    Rede com cabos blindados e conexes mini USB

    Sensores alimentados em 24 VCC.

    ngulos de medio de 7.

    Leitura online.

    2 tipos de rels com display grfico e comunicao sendo um tipo com display touch screen.

    Histrico de falhas com Time Stamp das 120 ltimas falhas.

    L e i t u r a e p r o t e o d e sobretemperatura de at 125 alvos pontuais ou de reas.

    L e i t u r a e p r o t e o d e sobretemperatura de at 125 pontos de temperatura de ar (corpo do sensor).

    Leituras e protees relativas a 4 entradas analgicas.

    Monitorao de 8 falhas externas.

    6 sadas digitais configurveis.

    Comunicao Modbus RTU ou PROFIBUS-DP.

    LED integrado ao sensor que pisca para detectar falhas ou localizao.

  • Z Y G G O T

    5

    Captao da medida de temperatura eInfluncia da emissividade na medio

    a + r + t = 1

    a r

    t

    Todo objeto com temperatura acima do zero absolutoirradia energia eletromagntica. Esta radiao na faixa do infravermelho no visvel, conforme pode ser visto na figura abaixo.

    Quando a radiao de um objeto alcana outro objeto, uma parte da energia absorvida, uma parte refletida e se o corpo no for opaco uma poro transmitida. A soma das partes dever ser sempre igual ao valor total que incidiu no objeto .

    Diante destes fatos, para se captar a temperatura de alvos desejados, deve-se ter sensores que captam tal energia eletromagntica.

    Superfciedo Corpo

    60%

    40%

    Ao se aquecer um material, sua superfcie no absorve toda a energia e acaba emitindo energia em infravermelho. Na prtica no existe nenhum material que seja um emissor ideal de radiao infravermelho. O emissor ideal recebe o nome de corpo negro. Os objetos tendem a irradiar menos energia que os corpos negros embora estejam na mesma temperatura.

    A tabela abaixo mostra a variao da emissividade de material para material.

    MATERIALEMISSIVIDADE

    (1m) Ferro e ao 0,35 Ferro e ao oxidado 0,85

    Aumnio 0,13

    Alumnio Oxidado 0,40 Cobre 0,06 Cobre oxidado 0,80 Tijolo 0,80 Asfalto 0,85 Amianto 0,90

    A emissividade de um objeto definida por: = t/b

    = Emissividade;t = radiao emitida a uma determinada temperatura;b = radiao emitida por um corpo negro a mesma temperatura

    FITA UNIDEXSoluo para as variaes de emissividade

    A maioria dos metais tm alterao da emissividade devido a oxidao. Um exemplo o cobre que em condio normal possui emissividade de 0,06 e quando oxidado 0,80.Para evitar reajustes de calibrao de emissividade dos sensores o Sistema Zyggot inclui o fornecimento de uma fita especial, colante, para temperaturas de at 250C, cujo valor de emissividade de 0,95 conhecido e garantido pela Varixx.Com a fita Unidex colada sobre a rea de medio de um alvo a ser medido obteremos sempre a leitura real de temperatura, no sendo necessrio se preocupar com a emissividade do material.Utilizando a fita, no necessrio calibrar ndices diferentes para cada material.A fita fornecida em dimenses de 50mmx50mm ou em rolo de 30m. Para cada sensor adquirido pelo cliente enviado uma unidade de fita.

    ROLO DE FITA UNIDEX 30m (ref. ZU3000)

    unidades deFITA UNIDEX 50m x 50m (ref. ZU50)

    Existem alguns medidores portteis que no possuem a possibilidade de se variar o ndice de emissividade, o que leva a medies errneas j que este ndice fixo em 0,95.Os sensores Zyggot permitem configurao do ndice de emissividade, garantindo medies precisas em qualquer material.

  • Z Y G G O T

    6

    Captao da medida de temperatura eComposio do produto

    POSICIONAMENTO DOS SENSORES E LEITURA DA TEMPERATURA

    Cada sensor mede, ao mesmo tempo, a temperatura do alvo e a temperatura do seu corpo (que equivale temperatura do ar circundante). Para o correto posicionamento dos sensores na rea de medio pr-definidada, acopla-se uma mira laser na parte frontal do sensor e efetua-se o direcionamento da luz laser para o centro da rea de medio, conforme figura abaixo.Deve-se definir a rea de medio no alvo desejado e, tendo o dimetro da rea de medio, define-se a distncia de posicionamento do sensor. A distncia entre a rea de medio e o sensor de no mximo 8 vezes o valor do dimetro da rea de medio para sensores de 7. A distncia mxima at o alvo deve ser menor que 10 metros.

    NGULO DE VISADA

    ngulo de visada o ngulo entre a perpendicular da rea alvo e o eixo que atravessa o sensor longitudinalmente.A curva abaixo mostra que somente comearia a haver diminuio da emissividade aps 55 de ngulo em relao a perpendicular do objeto medido. recomendado utilizar um ngulo mximo de visada de 45.

    rea demedio

    Sensor

    Alvo

    T alvo = T lida / E

    T lida corpo / ar

    Sensor - Duas Conexes mini-usb

    FIXAO DOS SENSORESFixe o sensor no local adequado utilizando as porcas rosqueaveis no seu corpo.

    SUPORTE - Suporte de fixao ajustvel

    Suporte mecnico que pode ser utilizado para o correto direcionamento do sensor em relao ao alvo facilitando a instalao.

    suporte de fixao(ref. ZSF1)

    rel Os rels esto disponveis em dois modelos diferentes.Comunicao Modbus RTU (VZX/B1/U)Comunicao Modbus RTU e tela Touch Screen (VZT/B1/U)

    Para utilizar comunicao PROFIBUS-DP acrescente /P ao final do cdigo. Exemplo.: VZX/B1/U/P

    Rel Modbus RTU(ref. VZX/B1/U)

    Rel Modbus RTU Touch Screen)(ref. VZT/B1/U)

    sensor tubular(ref. ZST/M/7/300/24)

  • Z Y G G O T

    7

    Composio do produto

    MALETA DE INSTALAO E MANUTENO

    A Maleta de Instalao e Manuteno Zyggot Temperatura (ref. VLP5) contm ferramentas essenciais para a instalao e manuteno dos sensores e rel. Tais ferramentas so: mira laser (ref. VLP2) e cabo configurador USB. importante que esta maleta esteja em posse do usurio do Sistema Zyggot Temperatura, a fim de executar eventuais manutenes de maneira adequada.

    fonte de alimentao

    O sistema Zyggot de Temperatura Tubular deve ser alimentado por uma fonte externa. A fonte VPS12024 possui capacidade de fornecer os 24 V necessrios para alimentar o CCrel e os sensores.

    Input: 90~132 / 180~264 VCA 120~375 VCCOutput: 24VDC/5A - 120W

    derivador ZTA

    O derivador ZTA (conector T) permite que seja possvel viabilizar vrios tipos de topologias e layouts, facilitando a instalao do sistema.Mais informaes vide pagina 9, 10 e 11.

    cabo mini usb

    O cabo mini USB realiza a comunicao entre sensores e sensores/rel. Os cabos esto disponveis nos seguintes tamanhos: 0,3m - ZCB/4/2U/030 0,5m - ZCB/4/2U/0501,0m - ZCB/4/2U/100 2,0m - ZCB/4/2U/2004,0m - ZCB/4/2U/400 6,0m - ZCB/4/2U/6008,0m - ZCB/4/2U/800

    mira laser

    A mira laser uma ferramenta essencial para direcionar o sensor ao alvo desejado. A mira facilita a instalao. O sistema alimentado por bateria de longa durao.

    cabo configurador USB

    O cabo configurador USB (ref. ZCC180) utilizado para conectar o sensor tubular ao PC. Possibilita a configurao de cada sensor pelo software gerenciador Zyggot.

    Fonte VPS 12024ref: VPS12024

    Derivador ZTAref: ZTA

    Mira Laser

    cabo mini USB

    maleta de instalao

    cabo configurador

  • Z Y G G O T

    8

    DisplayOs 2 tipos de rels disponveis possuem display grfico, com capacidade de trending. O trending mostra em tempo real grficos (mx. 3 variveis por grfico) o registro de comportamento de qualquer temperatura ou entrada analgica. Um dos rels apresentam tela Touch Screen em duas cores e 3,5.

    MedioO Rel Zyggot prov medio precisa de: At 125 temperaturas de alvos ou reas. At 125 temperaturas do corpo dos sensores. 4 Entradas analgicas de 10 bits para medio e proteo de variveis externas, como outras temperaturas adquiridas por termopares e outros; Horas de Operao.

    Memria de eventosO rel permite, memorizao e indicao das 120 ltimas falhas com data e hora da ocorrncia. Estas indicaes no so perdidas mesmo que o rel seja desligado.

    TopologiaOs Sensores tubulares permitem rpida e fcil instalao e parametrizao, com insero da emissividade do alvo na memria interna de cada sensor.

    Ferramenta de miraUm apontador laser que se rosqueia na parte frontal do corpo do sensor somente durante a instalao, permite rpida e segura fixao dos sensores, sendo retirado em seguida. Um nico apontador necessrio e suficiente.

    Ferramentas de programaoUm programa desenvolvido pela Varixx fornecido gratuitamente para facilitar ainda mais a parametrizao do rel. Mesmo sem o programa no h complexidade em parametrizar o rel pelo IHM que possui menus interativos e amigveis. Outro programa testa e parametriza cada sensor (emissividade e endereo).

    Portas de comunicaoO rel possui 2 portas de comunicao, sendo uma programvel (RS-232 / RS-485) para comunicao com supervisrio ou CLP atravs de protocolo Modbus RTU*. A outra porta de comunicao para a rede de sensores.

    *Opcionalmente pode-se adquir o rel com protocolo de comunicao PROFIBUS-DP.

    Entradas AnalgicasEsto disponveis 4 entradas analgicas de 10 bits que podem ser usadas para medio e proteo, ligadas a transdutores externos de temperatura e outros.

    Entradas DigitaisExistem 12 entradas digitais, sendo 8 configuradas para falhas externas, as quais podem por exemplo serem ligadas a micro-interruptores de porta de painel ou sensores de fluxo de ar de ventilao.

    Sadas digitaisEsto disponveis 6 sadas digitais sendo uma de alarme, uma de trip e 4 configurveis.

    diagrama unifilar e carastersticas principais

    TRIP

    TRIP

    ALARM

    ASSIGN

    RS232

    RS485

    ZYGGOT RELAY

    Metering

    C = 1 to 250 TargetC = 1 to 250 Case

    Analog 1 to 4

    12DIGITALINPUTS

    4ANALOGINPUTS

    6DIGITAL

    OUTPUTS

    REMOTE RESET

    EXTERNAL FAIL

    EXTERNAL FAIL

    MJ2PORT

    1 TO 125SENSORS

    Suporte de fixaoUm suporte mecnico ao qual o sensor se encaixa permite facilidade de ajuste do ponto de medio.

  • Z Y G G O T

    9

    esquema de ligao

    ENTRADAALIMENTAO

    Conversor

    SENSOR #1TUBULAR

    RJ-45CONECTOR

    MJ2

    (atrs do rel)

    RJ-45CONECTOR

    SENSOR #2TUBULAR

    SENSOR #3TUBULAR

    SENSOR #NTUBULAR

    MXIMO 125 SENSORES

    DE REDE ZFR

    RESISTOR DE TERMINAO

    FONTE DEALIMENTAO

    L N

    5A120-375VDC

    + +-- NC24 VDC

    Vout ADJ.

    DC ON

    90-132/180-264VAC

    NOTA: A SOMATORIA DA DISTNCIA DOS CABOS DEVE SER INFERIOR A 80m.

    MXIMO 80m DE CABO

    DE REDE ZFR

    RESISTOR DE TERMINAO

    O sistema Zyggot Temperatura Tubular possui 03 topologias diferentes de ligao da rede de sensores. Sero apresentados exemplos de ligao com os devidos limites a serem respeitados para garantir o correto funcionamento do sistema.

  • Z Y G G O T

    10

    ENTRADAALIMENTAO

    CONVERSOR

    RJ-45CONECTOR

    MJ2

    (atrs do rel)

    RJ-45CONECTOR

    SENSOR B.1TUBULAR

    SENSOR B.2TUBULAR

    SENSOR B.NTUBULAR

    SENSOR A.NTUBULAR

    SENSOR A.2TUBULARSENSOR A.1

    TUBULAR

    MXIMO 125 SENSORES

    RESISTOR DE TERMINAODE REDE ZFR

    +-

    ALIMENTAOFONTE DE

    L N

    5A120-375VDC

    + +-- NC24 VDC

    Vout ADJ.

    DC ON

    90-132/180-264VAC

    NOTA: PARA CADA UM DOS RAMOSA SOMATORIA DA DISTNCIA DOSCABOS DEVE SER INFERIOR A 80m.

    MXIM

    O 80m

    DE CA

    BOMXIMO 80m DE CABO

    RESISTOR DE TERMINAO

    DE REDE ZFR

    esquema de ligao

  • Z Y G G O T

    11

    ENTRADAALIMENTAO

    CONVERSOR

    RJ-45CONECTOR

    MJ2

    (atrs do rel)

    RJ-45CONECTOR

    MXIMO 125 SENSORES

    SENSOR #1

    TUBULAR

    SENSOR #2

    TUBULAR

    SENSOR #3

    TUBULAR

    SENSOR #4

    TUBULAR

    SENSOR #5

    TUBULAR

    SENSOR #6

    TUBULAR

    ALIMENTAOFONTE DE

    L N

    5A120-375VDC

    + +-- NC24 VDC

    Vout ADJ.

    DC ON

    90-132/180-264VAC

    +-

    SENSOR #7

    TUBULAR

    SENSOR #8

    TUBULAR

    SENSOR #9

    TUBULAR

    SENSOR #10

    TUBULAR

    SENSOR #11

    TUBULAR

    SENSOR #12

    TUBULAR

    SENSOR #13

    TUBULAR

    SENSOR #14

    TUBULAR

    SENSOR #15

    TUBULAR

    SENSOR #16

    TUBULAR

    SENSOR #17

    TUBULAR

    SENSOR #18

    TUBULAR

    SENSOR #119

    TUBULAR

    SENSOR #120

    TUBULAR

    SENSOR #121

    TUBULAR

    SENSOR #122

    TUBULAR

    SENSOR #123

    TUBULAR

    SENSOR #124

    TUBULAR

    NOTA: A SOMATORIA DA DISTNCIA DOS CABOS DEVE SER INFERIOR A 80m.

    RESISTOR DE TERMINAODE REDE ZFR

    RESISTOR DE TERMINAODE REDE ZFR

    esquema de ligao

  • Z Y G G O T

    CONEXO DE ALIMENTAO E COMANDO

    Uma vez instalado mecanicamente todo o sistema, faa as conexes eltricas de baixa tenso.

    Para o rel de monitorao, siga as conexes, de acordo com o esquema abaixo.

    Esto disponveis 8 entradas digitais de falha externa, uma entrada Reset e uma entrada de operao, que so usadas para informar que o equipamento entrou em operao, iniciando a contagem de tempo de Warm-up.

    Esto disponveis 4 sadas auxiliares digitais programveis, uma sada de Alarme/Alarme 1 e uma sada de Trip/Alarme 2.

    Esto disponveis ainda 4 entradas analgicas de 4 - 20 mA para monitorar grandezas externas.

    Os reles Zyggot possuem 2 portas de comunicao senso uma configurvel (RS232 / RS 485). Esta para comunicao com sistemas supervisrios ou CLPs atravs de protocolo de comunicao Modbus RTU e a outra para a rede dos sensores.

    Opcionalmente pode ser fornecido com porta PROFIBUS-DP. Nesta configurao o rel possui duplo canal de comunicao (Modbus RTU e PROFIBUS-DP).

    instalao do rel e circuitosde baixa tenso

    S1 S2 S3 S1 S2 S3

    24 VCC+-

    FONTE24 VCC

    (VPS12024)

    SERIALMODBUS

    SENSORESREDEREL ZYGGOT

    MJ1

    MJ2

    IN1 - J1/1-I1

    IN2 - J1/2-I2

    IN3 - J1/3-I3

    IN4 - J1/4-I4

    IN5 - J1/5-I5

    IN6 - J1/6-I6

    IN7 - J1/7-I7

    IN8 - J1/8-I8

    IN9 - J1/9/H1

    COMUM - J1/10-0V

    IN10 - J2/1-I10/H2

    IN11 - J2/2-I11/H3Operao

    ResetIn12 - J2/3-I12/H4

    OUT1-ALARMEJ2/4-R1

    J2/5-C1

    OUT2-TRIP J2/6-R2J2/7-C2

    OUT3-AUX1J2/8-R3J2/9-C3

    OUT4-AUX2J2/10-R4J2/11-C4

    OUT5-AUX3J2/12-R5J2/13-C5

    OUT6-AUX4J2/14-R6J2/15-C6

    V+V-

    Ai1 - J1/11-A1

    Ai2 - J1/12-A2

    Ai3 - J1/13-A3

    Ai4 - J1/14-A4

    AI - J1/15-0VLoop decorrente

    -

    -

    +

    +

    -+

    +-

    90 a 132 / 180 a 264 VCA120 a 375 VCC

    Profibus(opcional)

    -+-+

    COMUM

    12

  • Z Y G G O T

    Readings 4 External Analog Signal

    Readings - 125 Target C

    Readings - 125 Case / Air C

    Event Recorder - 120 Tags

    Trendings - Real time curves

    30 Anunciator w/ Time Stamp

    48 Trip / Incomplete Sequence

    94 8 x Assignable External

    49

    49 125 Target Overtemperature

    125 Case / Air Overtemp.

    TR

    IP

    AL

    AR

    M

    ANSI DESCRIPTION Mo

    nito

    rPROTECES E FUNES

    tabela de funesteste de integridade overlays

    OVERLAY REL VZX OVERLAY REL VZT

    TESTE DE INTEGRIDADE DO SISTEMA

    Uma vez instalado o sistema pode-se checar a integridade do mesmo, comandando a funo de piscar o LED traseiro de cada sensor. Entre na tela de comando de Piscar led dos sensores. No Rel VZX. Pressione a tecla K9; no Rel VZT. Pressione a tecla K4. Insira Sensor = 0 (todos os LEDs dos sensores devem piscar ao comando ON e parar de piscar ao comando OFF. Insira o nmero de cada sensor, de 1 a 125 e ao comando On s ele piscar.

    13

  • Z Y G G O T

    14

    especificaes tcnicas modelos vzx e vzt

    * Nota: Para reles com comunicao em PROFIBUS-DP utilizar os cdigos: VZX/B1/U/P ou VZT/B1/U/P

    opo profibus dp

    ZYGGOT Specifications

    Relay General Specifications (for all models)

    Models VZX

    Required Supply Voltage

    24 VDC

    Required Power

    130 mA @ 24 VDC

    Required Power (Inrush)

    30 A for 1 ms @ 24 VDC

    Primary Power Range

    10 30 VDC

    Relative Humidity

    5 to 95% Non-condensing

    Operating Temperature

    0 to 50 Celsius

    Terminal Type

    Screw Type, 5 mm Removable

    Weight

    12 oz. (340.19 g) 12 oz. (340.19 g)Dimensions (mm)

    96H x 96W x 57,5D

    Display

    2 color graphical LCD

    User Keys

    20

    Protocols Supported

    Modbus RTU, PROFIBUS-DP*

    Serial Ports

    2 RS232 / RS485

    CE

    Compliant

    Models VZT

    24 VDC

    130 mA @ 24 VDC

    30 A for 1 mS @ 24 VDC

    5 to 95% Non-condensing

    0 to 50 Celsius

    Screw Type, 5 mm Removable

    96H x 96W x 57,5D

    3.5 LCD Graphical 2 Color Touch Screen

    5

    Modbus RTU, PROFIBUS-DP*

    2 RS232 / RS485

    Compliant

    10 30 VDC

    Dimensions PROFIBUS (mm) 96H x 96W x 68D

    96H x 96W x 68D

    caixa de derivao traseira (zxt-2)ZYGGOT Specifications

    Model ZXT-2

    Required Supply Voltage

    24 VDC

    Max. Power

    General Specifications

    Dimensions (mm) 86,8H x 86,8W x 41,5D

    2,5 A @ 24 VDC / 60W

  • Z Y G G O T

    15

    ZYGGOT Relays Specifications (Models VZX and VZT)

    Digital DC Inputs

    Inputs per Module

    12

    Commons per Module

    1

    Input Voltage Range

    10 VDC to 30 VDC

    Absolute Max. Voltage

    35 VDC Max.

    Nominal Input Impedance

    10 k

    Upper Threshold Current

    0.8 / -1.6 mA

    Lower Threshold Current

    0.3 / -2.1 mA

    Max Upper Threshold

    8 VDC

    Min Lower Threshold

    3 VDC

    OFF to ON Response

    1 ms

    ON to OFF Response

    1 ms

    Isolation

    1000 VAC

    ZYGGOT Relays Specifications (Models VZX and VZT)Digital Relay Outputs

    Type Relay - Dry contactOutputs per Module 6 NO RelaysCommons per Module 6Max. Output

    3A at 250 VAC, resistive

    Max. Total Current

    5 A continuous

    Max. Output Voltage

    275 VAC , 30 VDC

    Min. Output Voltage

    -

    Max. Switched Power

    1250 VA, 150W

    Contact Isolation to ground

    1000 VAC

    Max. Voltage Drop at Rated Current

    0.5 V

    Max. Inrush Current

    -

    Expected Life

    No load: 5,000,000

    Rated load: 100,000

    Max. Switching Rate

    300 CPM at no load

    20 CPM at rated load

    ZYGGOT SpecificationsTemperature Sensors (No Contact)

    Tightening 2 ScrewsPower Supply Range 12 - 24 VDC

    Sensor Measurement Angles 7Temperature Ranges 0 - 300 C

    Sensor Transmission types Shielded CableTemperature accuracy +/- 2.5%

    Temperature Resolution 1 C

    Maximum measurement range (distance from sensor to target)

    10 m

    Pointing

    Removable Laser Pointing DeviceMax. Sensors per Relay

    125

    CE

    Compliant

    Required Power 4,5 mA @ 24 VDC

    Power Supply (VPS12024)

    Rates Input Voltage

    Input Voltage Max.Range

    90-132 / 180-264 VAC

    120-375 VDC

    115/230 (auto select)

    Output Power 120W

    Output Voltage 24 VDCOutput Current 5 AEfficiency 84% (min)

    86% (typical) Dimensions (mm)

    124,5H x 64W x 116,6D

    especificaes tcnicas modelos vzx e vzt

  • POWER SUPPLYSignal Pin DescriptionV+ Input power supply voltageV- Input power supply groundGnd Frame Ground

    CharacteristicsDisplay Type (LCD with backlight): MonocromeDisplay Size: 3.78W x 3.78H (96x96mm)Display Screen Dimensions: 1.97W x 1.14H (50x29mm)Functions Keys: 20Number of Colors: 2Power Steady State Current: 130mA @ 24VDCInrush Current: 30A @ 24VDC for 1ms.Height: 3.78 (96.0 mm)Width: 3.78 (96.0 mm)Mounting Depth: 2.264 (57.5 mm)Weight 12 oz (340.19 g)Keypad Material: Lexan HP92 by GE Plastics.Protocols supported Serial Ports: Modbus Slave, and ASCII Read and WriteSerial Ports: 2 RS-232 / RS-485 Ports.Temperature & Humidity: 32 - 122F (0 - 50C),5 to 95% Non-condensingUL / CE Compliant

    GENERAL CHARACTERISTICS Graphical LCD Screen w/ Backlight. 24 VDC RS-232 / RS-485 Serial Ports. Integrated Bezel. Real-Time Clock. Flash Memory for easy field upgrades. 20 Function Keys.

    1 2 3 4 5 6 7 8

    MJ 1 (PORT 1) MODULAR JACK

    MJ 1 (PORT 1)PIN

    1 RX+ / TX+RX- / TX -2

    3 CTS4 RTS5 +5V / 60 mA max6 0 V7 RXD8 TXD

    Output Power Supply Max 150 mA

    SIGNAL

    especificaes tcnicas modelos vzx de 96 x 96mm com display LCD Z Y G G O T

    16

  • CharacteristicsDisplay Type (LCD with backlight): Monocrome Touch ScreenDisplay Size: 3.78W x 3.78H (96x96mm)Display Screen Dimensions: 2.82W x 2.03H (71,6 x 51,4mm)Functions Keys: 5Number of Colors: 2Power Steady State Current: 130mA @ 24VDCInrush Current: 30A @ 24VDC for 1ms.Height: 3.78 (96.0 mm)Width: 3.78 (96.0 mm)Mounting Depth: 2.264 (57.5 mm)Weight 12 oz (340.19 g)Keypad Material: Lexan HP92 by GE Plastics.Protocols supported Serial Ports: Modbus Slave, and ASCII Read and WriteSerial Ports: 2 RS-232 / RS-485 Ports.Temperature & Humidity: 32 - 122F (0 - 50C),5 to 95% Non-condensingUL / CE Compliant

    especificaes tcnicas modelos vzt de 96 x 96mm com display LCD Touch Screen Z Y G G O T

    17

    GENERAL CHARACTERISTICS Graphical LCD Screen w/ Backlight. 24 VDC RS-232 / RS-485 Serial Ports. Integrated Bezel. Real-Time Clock. Flash Memory for easy field upgrades. 20 Function Keys.

    POWER SUPPLYSignal Pin DescriptionV+ Input power supply voltageV- Input power supply groundGnd Frame Ground

    1 2 3 4 5 6 7 8

    MJ 1 (PORT 1) MODULAR JACK

    MJ 1 (PORT 1)PIN

    1 RX+ / TX+RX- / TX -2

    3 CTS4 RTS5 +5V / 60 mA max6 0 V7 RXD8 TXD

    Output Power Supply Max 150 mA

    SIGNAL

  • Modelo VZX

    mecnica modelos vzx e vzt de 96x96mmcom display LCD Z Y G G O T

    18

    Modelo VZT

    Modelo PROFIBUS-DP (VZX e VZT)

    MemorySlot

    J2

    Power

    MJ2

    MJ1

    J1

    Modelo Padro (VZX e VZT)

    3.74 [95 mm]

    4.016 [102 mm]

    2.264 [57.5 mm]

    2.704 [68.68 mm]

    4.18 [106.18 mm]

    4.456 [113.18 mm]

  • Z Y G G O T

    19

    TELAS PRINCIPAISSo 12 telas selecionadas pelas teclas de navegao (,) que mostram dezenas de informaes como Mxima temperatura de alvo e ar, Nmero de sensores respondendo, Total de alarmes, Total de trips, Resumo de falhas ativas, Status Modbus, Status Profibus, Status Rede dos sensores, Status entradas e sadas, digitais, e Status dos grupos de sensores.

    TELAS DE SENSORES SELECIONADOS

    So 20 telas que mostram 20 temperaturas de alvo e 20 temperaturas de ar selecionveis. Os ndices dos sensores so livremente inseridos pelo teclado frontal, mudando a indicao. O usurio pode portanto programar os principais sensores para indicao nestas telas de fcil leitura. Netas telas as condies de alarme e trip so indicadas para cada ponto selecionado, piscando o ndice e a leitura respectivamente.

    TELAS de INDICAES DE ALARME E TRIP PARA OS ALVOSSo telas que mostram todas as indicaes de alarme e trip para os alvos existentes. Quando o nvel foi atingido o quadrado da direita se torna preto. TELAS DE ALARME E TRIP PARA os

    CORPOS DE SENSOR / ARSo telas que mostram todas as indicaes de alarme e trip para os corpos dos sensores existentes, que na realidade a temperatura do ar circundante. Quando o nvel foi atingido o quadrado da direita se torna preto.

    C83,5

    C25,4

    T 101:

    T120:

    SELECT TARGET ST 5

    Resumo de telas(modelos vzx e vzt)

    C83,5 C25,4

    > TARG:

    > AIR:

    FA AIR TA NR AL TR1

    OK S: 50 NR S: 0

  • Z Y G G O T

    20

    48 C

    32

    64

    128

    57

    T001:

    T002:

    T003:

    T004:

    T005:

    TARGET T01

    48 C

    32

    64

    128

    57

    A001:

    A002:

    A003:

    A004:

    A005:

    AIR T01

    TELAS DE TEMPERATURASSo telas que mostram todas as temperaturas do sistema em graus centgrados ou Fahrenheit.

    TELAS DE STATUS DE SENSORESSo telas mostram todas os sensores. Se o sensor no estiver respondendo o quadrado da direita se torna preto.

    TELAS DE ALARMES/FALHAS ATIVASSo dezenas de telas que mostram todas as possibilidades de falhas monitoradas pelo sistema.

    Resumo de telas(modelos vzx e vzt)

    TELAS DE RESUMO E HISTRICOSo vrias telas que apresentam informaes como a vida total do rel, informaes sobre a planta e local de montagem, histrico de Alarmes/Falhas e Alarmes/Falhas ativas.

  • Z Y G G O T

    21

    PROGRAMAO

    Para entrar no menu de programao pressione a tecla 0 com o smbolo de um menu no rel VZX ou a tecla F4 com o smbolo de um menu no rel VZT. Se a senha inserida anteriormente for 0 o menu aparecer imediatamente, caso contrrio insira a senha correta para ter acesso ao menu.

    OPERAO

    As teclas dos rels podem ter mais de uma funo. Pressione uma vez para se ter acesso a primeira funo ou srie de telas e mais uma vez para a Segunda funo e mais uma terceira vez caso a tecla tenha 3 funes. Isto intuitivo e poder se observar a mudana das telas relativas a cada funo. Uma vez estando em um grupo de telas (por exemplo Telas Principais pode-se

    navegar por todas as telas deste grupo pelas teclas de navegao (,) a esquerda e direita. H teclas especiais para se chamar a tela de alarmes e a tela de eventos (at 120 eventos na lista).

    Nas prximas pginas sero apresentados os fluxos de telas do programa para reles VZX e VZT.

    FINALIZANDO O STARTUP

    Uma vez checada a integridade do sistema, termine a programao total do sistema, pelo prprio rel de proteo ou pelo programa de configurao pelo PC (consulte o manual). Efetue vrias leituras e verifique a consistncia das mesmas em relao a temperaturas de alvos conhecidas e temperatura ambiente. Simule atuaes de alarmes e trips, reduzindo os nveis de algum dos pontos provisoriamente para valores abaixo da temperatura atual e analise a atuao dos contatos de sada, de acordo com a configurao efetuada. Verifique tambm (se forem utilizadas), as indicaes das entradas analgicas e indicaes das entradas digitais externas.

    Resumo de telas(modelos vzx e vzt)

    TELAS DADOS E PARAMETROS

    DATA TA1

    WARN / FAILS

    ACTIVE FAILS 1/2

    ACTIVE FAILS 2/2

    COMMUNICATION

    DIG INPUTSDIG OUTPUTSSTATISTICSINFO

    TELAS DE TRENDINGSo vrias telas que mostram curvas em tempo real das variveis monitoradas como temperaturas e entradas analgicas.

    0 1000TIME (s)

    TC

    200

    Resumo de programao e operao

  • Z Y G G O T

    22

    fluxo de telas rel modelo VZXteclas de funes

    Tecla K1 - Telas Principais

    K1QZ1

    68

    131

    C83,5 C25,4

    > TARG:

    > AIR:

    FA AIR TA NR AL TR1

    OK S: 50 NR S: 0

    F1 F2F1 F2

    Teclas F1/F2 - Resumo e Histrico

  • 23

    Tecla K2 - Alvos Selecionados

    C83,5

    C25,4

    T 21:

    T32:

    SELECT TARGET ST1

    C83,5

    C26,7

    T 50:

    T52:

    SELECT TARGET ST2

    C83,5

    C27,2

    T 32:

    T33:

    SELECT TARGET ST3

    C83,5

    C32,4

    T 101:

    T120:

    SELECT TARGET ST10

    K2ABC2

    S125: 68

    S089: 131

    SELECT TARG ST01

    K2

    C23,5

    C25,4

    A 31:

    A 42:

    SELECT AIR SA1

    C24,2

    C33,9

    A 51:

    A 52:

    SELECT AIR SA2

    C26,5

    C26,2

    A 71:

    A 73:

    SELECT AIR SA3

    C28,8

    C30,4

    A 101:

    A 120:

    SELECT AIR SA10

    ABC2

    S125: 68

    S089: 131

    SELECT TARG ST01

    Tecla K3 - Todos Alvos e Corpos

    K3

    25 C

    26

    24

    28

    28

    A001:

    A002:

    A003:

    A004:

    A005:

    AIR A01 28 C

    32

    33

    34

    42

    A006:

    A007:

    A008:

    A009:

    A010:

    AIR A02 44 C

    43

    38

    38

    37

    A011:

    A012:

    A013:

    A014:

    A015:

    AIR A03 36 C

    37

    54

    54

    55

    A121:

    A122:

    A123:

    A124:

    A125:

    AIR A25

    K3

    48 C

    47

    49

    128

    57

    T001:

    T002:

    T003:

    T004:

    T005:

    TARGET T01 53 C

    64

    65

    63

    58

    T006:

    T007:

    T008:

    T009:

    T010:

    TARGET T02 59 C

    57

    64

    64

    65

    T011:

    T012:

    T013:

    T014:

    T015:

    TARGET T03 97 C

    99

    121

    120

    118

    T121:

    T122:

    T123:

    T124:

    T125:

    TARGET T25

    DEF3

    T003 70 T005 92

    T002 45 T004 88

    T001 68TARG

    CCT01

    DEF3

    T003 70 T005 92

    T002 45 T004 88

    T001 68TARG

    CCT01

    Z Y G G O Tfluxo de telas rel modelo VZXteclas de funes

  • 24

    Z Y G G O T

    K5

    AIR ALARM AA1

    A001

    A002

    A003

    A004

    A005

    A006

    A007

    A008

    A009

    A010

    A011

    A012

    A013

    A014

    A015

    AIR ALARM AA2

    A016

    A017

    A018

    A019

    A020

    A021

    A022

    A023

    A024

    A025

    A026

    A027

    A028

    A029

    A030

    AIR ALARM AA9

    A121

    A122

    A123

    A124

    A125

    K5

    AIR TRIP AT1

    A001

    A002

    A003

    A004

    A005

    A006

    A007

    A008

    A009

    A010

    A011

    A012

    A013

    A014

    A015

    AIR TRIP AT2

    A016

    A017

    A018

    A019

    A020

    A021

    A022

    A023

    A024

    A025

    A026

    A027

    A028

    A029

    A030

    AIR TRIP AT9

    A121

    A122

    A123

    A124

    A125

    JKL5

    VVNFTTFH

    HFGHFGHFGH

    FGHFGHFH

    Addfdddh

    Hfhfhfghfhfggh

    Fghfghfghfgh

    FghfghfghhHfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfgh fghfghfgh fgghfg

    JKL5

    VVNFTTFH

    HFGHFGHFGH

    FGHFGHFH

    Addfdddh

    Hfhfhfghfhfggh

    Fghfghfghfgh

    FghfghfghhHfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfgh fghfghfgh fgghfg

    K4

    TARGET ALARM TA1

    T001

    T002

    T003

    T004

    T005

    T006

    T007

    T008

    T009

    T010

    T011

    T012

    T013

    T014

    T015

    TARGET ALARM TA2

    T016

    T017

    T018

    T019

    T020

    T021

    T022

    T023

    T024

    T025

    T026

    T027

    T028

    T029

    T030

    TARGET ALARM TA9

    T121

    T122

    T123

    T124

    T125

    K4

    TARGET TRIP TT1

    T001

    T002

    T003

    T004

    T005

    T006

    T007

    T008

    T009

    T010

    T011

    T012

    T013

    T014

    T015

    TARGET TRIP TT2

    T016

    T017

    T018

    T019

    T020

    T021

    T022

    T023

    T024

    T025

    T026

    T027

    T028

    T029

    T030

    TARGET TRIP TT9

    T121

    T122

    T123

    T124

    T125

    GHI4

    VVNFTTFH

    HFGHFGHFGH

    FGHFGHFH

    Addfdddh

    Hfhfhfghfhfggh

    Fghfghfghfgh

    FghfghfghhHfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfgh fghfghfgh fgghfg

    GHI4

    VVNFTTFH

    HFGHFGHFGH

    FGHFGHFH

    Addfdddh

    Hfhfhfghfhfggh

    Fghfghfghfgh

    FghfghfghhHfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfgh fghfghfgh fgghfg

    Tecla K4 - Alarmes e Trips de Alvos

    Tecla K5 - Alarmes e Trips de Corpos

    fluxo de telas rel modelo VZXteclas de funes

  • 25

    Z Y G G O Tfluxo de telas rel modelo VZXteclas de funes

    K6MNO6

    AFGHT

    MTDGI

    CVFYD

    ADSCR

    HT

    GIYDo Tecla K6 - Falhas Ativas e Dados

    K6

    DATA TA1

    WARN / FAILS

    ACTIVE FAILS 1/2

    ACTIVE FAILS 2/2

    COMMUNICATION

    DIG INPUTSDIG OUTPUTSSTATISTICSINFO

    WARN / FAIL TA1

    ALARM ONTRIP ONFAIL ACTIVE

    ACTIVE FAILS 2/2 TA1

    EXT FAIL 1EXT FAIL 2EXT FAIL 3EXT FAIL 4EXT FAIL 5EXT FAIL 6EXT FAIL 7EXT FAIL 8ALRM ANALOG 1FAIL ANALOG 1ALRM ANALOG 2FAIL ANALOG 2ALRM ANALOG 3FAIL ANALOG 3ALRM ANALOG 4FAIL ANALOG 4

    DIG INPUTS TA1

    DIG INPUT 1DIG INPUT 2DIG INPUT 3DIG INPUT 4DIG INPUT 5DIG INPUT 6DIG INPUT 7DIG INPUT 8DIG INPUT 9DIG INPUT 10DIG INPUT 11DIG INPUT 12

    ACTIVE FAILS 1/2 TA1

    SENSOR COMM FAILPROFIBUS FAILSENSOR NRTARGET HOTAIR HOTOPERATING HOUR

    COMMUNICATION TA1

    SENSOR COMM OKMODBUS ACTIVEMODBUS OKMODBUS ERROR

    DIG OUTPUTS TA1

    DIG OUTPUT 1DIG OUTPUT 2DIG OUTPUT 3DIG OUTPUT 4DIG OUTPUT 5DIG OUTPUT 6

    STATISTICS TA1

    OPER.:N ALARMSN TRIPS

    MNO6AFGHT

    MTDGI

    CVFYD

    ADSCR

    HT

    GIYDo Tecla K6 - Dados e Parmetros

    INFO TA1

    SOFTWARE VERSION:

    AIR GAGE:

    PLANT:

    LOCATION:

    PANEL:

    INIT DATE:

  • 26

    Z Y G G O T

    K7

    0 5,70TIME (s)

    ALL TARGETS

    TC

    200

    1

    ALL AIR

    0 5,70TIME (s)

    TC

    200

    2

    S001 S034 S120

    0 114TIME (h)

    TC

    200

    12

    K7

    48 C

    47

    49

    128

    120

    D001:

    D002:

    D003:

    D004:

    D005:

    LAST M01 113 C

    62

    68

    70

    84

    D006:

    D007:

    D008:

    D009:

    D010:

    LAST M02 55 C

    60

    73

    78

    74

    D121:

    D122:

    D123:

    D124:

    D125:

    LAST M25

    K7

    12 VALID

    10

    11

    21

    20

    D001:

    D002:

    D003:

    D004:

    D005:

    DT% M01 20 VALID

    6

    11

    8

    15

    D006:

    D007:

    D008:

    D009:

    D010:

    DT% M02 17 VALID

    7

    0

    2

    1

    D121:

    D122:

    D123:

    D124:

    D125:

    DT% M25

    7 PRS

    7 PRS

    7 PRS

    K88 TUV

    + -

    Tecla K7 - Trendings e Diferencial

    Tecla K8 - No Respondendo

    fluxo de telas rel modelo VZXteclas de funes

    K99 WXY

    Tecla K9 - Comando de Flash

  • 27

    Z Y G G O T

    K10

    SENSORS

    N SENSORS:BLINK SENSORS:GAGE AIR TEMP:

    BLOCK PROGRAMINGBLOCK 1BLOCK 2BLOCK 3BLOCK 4BLOCK 5DO BLOCK PROGRAMM

    BLOCK 1START:END:

    TARGET ALRM:TARGET TRIP:

    ANALOG INPUTSAI1 / NAME:AI2 / NAME:AI3 / NAMEAI4 / NAME:READ MODE:SCALE:

    TARGET ALRM LVS 01-10A1:A2:A3:A4:A5:A6:A7:A8:A9:A10:

    TARGET ALRM LVS 121-125A121:A122:A123:A124:A125:

    TARGET TRIP LVS 01-10T1:T2:T3:T4:T5:T6:T7:T8:T9:T10:

    TARGET TRIP LVS 121-125T121:T122:T123:T124:T125:

    TRENDING CONFIGSCALE:INDEX MODE:HMI RESET:INDEX 3A-7A:INDEX 3B-3B:INDEX 3C-3C:INDEX 8A-12A:INDEX 8B-12B:INDEX 8C-12C:

    CLEAR DATACLEAR HISTORYCLEAR STATISTICS

    TARGET ALARM LEVELSTARGET 01-10TARGET 11-20TARGET 21-30TARGET 31-40TARGET 41-50TARGET 51-60TARGET 61-70TARGET 71-80TARGET 81-90TARGET 91-100TARGET 101-120TARGET 121-125

    TARGET TRIP LEVELSTARGET 01-10TARGET 11-20TARGET 21-30TARGET 31-40TARGET 41-50TARGET 51-60TARGET 61-70TARGET 71-80TARGET 81-90TARGET 91-100TARGET 101-120TARGET 121-125

    PROTECTIONS 1/3NOT RESPONDINGTARGET ALARMTARGET TRIPAIR ALARMAIR TRIPOPERATING HOURSENSOR COMM FAILPROFIBUS FAILDIFFERENTIALGROUP

    NOT RESPONDINGACTION:AUX OUTPUT:

    AIR TRIPACTION:AUX OUTPUT:

    OPERATING HOURACTION:HOUR:AUX OUTPUT:

    DIFFERENTIALACTION:HI LEVEL:PERIOD:WARM UP:AUX OUTPUT:

    PROTECTIONS 2/3ANALOG 1 ALARMANALOG 1 TRIPANALOG 2 ALARMANALOG 2 TRIPANALOG 3 ALARMANALOG 3 TRIPANALOG 4 ALARMANALOG 4 TRIP

    ANALOG 1 ALARMACTION:LEVEL HIGH:AUX OUTPUT:

    ANALOG 4 TRIPACTION:LEVEL HIGH:AUX OUTPUT:

    PROTECTIONS 3/3EXTERNAL FAIL 1EXTERNAL FAIL 2EXTERNAL FAIL 3EXTERNAL FAIL 4EXTERNAL FAIL 5EXTERNAL FAIL 6EXTERNAL FAIL 7EXTERNAL FAIL 8

    EXTERNAL FAIL 1ACTION:TRIP DELAY:AUX OUTPUT:ASSIGN NAME:

    EXTERNAL FAIL 8ACTION:TRIP DELAY:AUX OUTPUT:ASSIGN NAME:

    0

    Tecla K10 - Menu de Programao

    fluxo de telas rel modelo VZXteclas de funes

    MAIN MENURELAY CONFIGPARAMETERS CONFIGSENSORSBLOCK PROGRAMINGANALOG INPUTSMODBUS CONFIGSENSOR COMMUNICATION

    TARGET ALRM LVLSTARGET TRIP LVLSTRENDING CONFIGCLEAR DATA

    PROTECTIONS

    RELAY CONFIGLANGUAGE:SET R. TIME CLOCK:PROF. USE:PROF. NODE:PLANT:LOCATION:PANEL:INIT DATE:

    MODBUS CONFIGBAUD RATE:ADDRESS:PARITY:HANDSHAKE:TIMEOUT:STOP BITS:PORT MODE:MODBUS:

    SENSOR COMMUNICATION

    BAUD RATE:

    TIMEOUT:

    BLOCK 5START:END:

    TARGET ALRM:TARGET TRIP:

    PROTECTIONSPROTECTIONS 1

    PROTECTIONS 2

    PROTECTIONS 3

    SENSOR COMM FAILACTION:AUX OUTPUT:

    PROFIBUS FAILACTION:FAULT RESET:D.O. AUX:

    PARAMETERS CONFIGCENTIG/FAHRENHEIT:RESET ON FAIL:

    AIR ALRM LVL:AIR TRIP LVL:CALL SCR ON FAIL:CALL SCR ON ALM:RTN TO MAIN:MENU PASS:

    W/ FLASH ON:

    GROUP 1TRG ALRM ACT:TRG TRIP ACT:AIR ALRM ACT:AIR TRIP ACT:TRG ALRM AUX:TRG TRIP AUX:AIR ALRM AUX:AIR TRIP AUX:

    GROUP 5TRG ALRM ACT:TRG TRIP ACT:AIR ALRM ACT:AIR TRIP ACT:TRG ALRM AUX:TRG TRIP AUX:AIR ALRM AUX:AIR TRIP AUX:

    GROUPGROUP 1GROUP 2

    GROUP 4GROUP 3

    GROUP 5

  • 28

    Z Y G G O Tfluxo de telas rel modelo VZTteclas de funes

    C83,5 C25,4

    > TARG:

    > AIR:

    FA AIR TA NR AL TR1

    OK S: 50 NR S: 0

    K0F0SYS

    AFGHT

    MTDGI

    CVFYD

    ADSCR

    HT

    GIYDo Tecla K0 - Telas Principais

    K0F0SYS

    AFGHT

    MTDGI

    CVFYD

    ADSCR

    HT

    GIYDo Tecla K0 - Falhas Ativas e Dados

    K0F0SYS

    AFGHT

    MTDGI

    CVFYD

    ADSCR

    HT

    GIYDoTecla K0 - Resumo e Histrico

  • 29

    Z Y G G O Tfluxo de telas rel modelo VZTteclas de funes

    C83,5

    C25,4

    T 21:

    T32:

    SELECT TARGET St01

    C83,5

    C26,7

    T 50:

    T52:

    SELECT TARGET St02

    C83,5

    C27,2

    T 32:

    T33:

    SELECT TARGET St03

    C83,5

    C32,4

    T 101:

    T120:

    SELECT TARGET ST10

    F1

    S125: 68

    S089: 131

    SELECT TARG ST01

    K1

    C23,5

    C25,4

    C 31:

    C42:

    SELECT CASE SC01

    C24,2

    C33,9

    C 51:

    C52:

    SELECT CASE SC02

    C26,5

    C26,2

    T 71:

    C73:

    SELECT CASE SC03

    C28,8

    C30,4

    C 101:

    C120:

    SELECT CASE SC10

    F1

    S125: 68

    S089: 131

    SELECT TARG ST01

    K1

    48 C

    47

    49

    128

    57

    T001:

    T002:

    T003:

    T004:

    T005:

    TARGET T01 53 C

    64

    65

    63

    58

    T006:

    T007:

    T008:

    T009:

    T010:

    TARGET T02 59 C

    57

    64

    64

    65

    T011:

    T012:

    T013:

    T014:

    T015:

    TARGET T03 97 C

    99

    121

    120

    118

    T121:

    T122:

    T123:

    T124:

    T125:

    TARGET T25

    F1

    S125: 68

    S089: 131

    SELECT TARG ST01

    K1

    Tecla K1 - Alvos Selecionados

    Tecla K1 - Corpos Selecionados

    Tecla K1 - Todos Alvos

    F1

    S125: 68

    S089: 131

    SELECT TARG ST01

    K1 Tecla K1 - Todos Corpos

    25 C

    26

    24

    28

    28

    A001:

    A002:

    A003:

    A004:

    A005:

    AIR A01 28 C

    32

    33

    34

    42

    A006:

    A007:

    A008:

    A009:

    A010:

    AIR A02 44 C

    43

    38

    38

    37

    A011:

    A012:

    A013:

    A014:

    A015:

    AIR A03 36 C

    37

    54

    54

    55

    A121:

    A122:

    A123:

    A124:

    A125:

    AIR A25

  • 30

    Z Y G G O T

    TARGET ALARM TA1

    T001

    T002

    T003

    T004

    T005

    T006

    T007

    T008

    T009

    T010

    T011

    T012

    T013

    T014

    T015

    TARGET ALARM TA2

    T016

    T017

    T018

    T019

    T020

    T021

    T022

    T023

    T024

    T025

    T026

    T027

    T028

    T029

    T030

    TARGET ALARM TA9

    T121

    T122

    T123

    T124

    T125

    Tecla K2 - Alarmes de Alvos

    F2

    VVNFTTFH

    HFGHFGHFGH

    FGHFGHFH

    Addfdddh

    Hfhfhfghfhfggh

    Fghfghfghfgh

    FghfghfghhHfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfgh fghfghfgh fgghfg

    K2

    TARGET TRIP TF1

    T001

    T002

    T003

    T004

    T005

    T006

    T007

    T008

    T009

    T010

    T011

    T012

    T013

    T014

    T015

    TARGET TRIP TF2

    T016

    T017

    T018

    T019

    T020

    T021

    T022

    T023

    T024

    T025

    T026

    T027

    T028

    T029

    T030

    TARGET TRIP TF9

    T121

    T122

    T123

    T124

    T125

    F2

    VVNFTTFH

    HFGHFGHFGH

    FGHFGHFH

    Addfdddh

    Hfhfhfghfhfggh

    Fghfghfghfgh

    FghfghfghhHfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfgh fghfghfgh fgghfg

    K2Tecla K2 - Trips de Alvos

    fluxo de telas rel modelo VZTteclas de funes

    Tecla K2 - Alarmes de Corpos

    F2

    VVNFTTFH

    HFGHFGHFGH

    FGHFGHFH

    Addfdddh

    Hfhfhfghfhfggh

    Fghfghfghfgh

    FghfghfghhHfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfgh fghfghfgh fgghfg

    K2

    AIR ALARM AA1

    A001

    A002

    A003

    A004

    A005

    A006

    A007

    A008

    A009

    A010

    A011

    A012

    A013

    A014

    A015

    AIR ALARM AA2

    A016

    A017

    A018

    A019

    A020

    A021

    A022

    A023

    A024

    A025

    A026

    A027

    A028

    A029

    A030

    AIR ALARM AA9

    A121

    A122

    A123

    A124

    A125

    F2

    VVNFTTFH

    HFGHFGHFGH

    FGHFGHFH

    Addfdddh

    Hfhfhfghfhfggh

    Fghfghfghfgh

    FghfghfghhHfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfghfghfghfghfgghfghfgghfgghrtgthfgghfghfh

    Hfgghfghfgh fghfghfgh fgghfg

    K2Tecla K2 - Trips de Corpos

    AIR TRIP AT1

    A001

    A002

    A003

    A004

    A005

    A006

    A007

    A008

    A009

    A010

    A011

    A012

    A013

    A014

    A015

    AIR TRIP AT2

    A016

    A017

    A018

    A019

    A020

    A021

    A022

    A023

    A024

    A025

    A026

    A027

    A028

    A029

    A030

    AIR TRIP AT9

    A121

    A122

    A123

    A124

    A125

  • 31

    Z Y G G O T

    0 5,70TIME (s)

    ALL TARGETS

    TC

    200

    1

    ALL CASES

    0 5,70TIME (s)

    TC

    200

    2

    S001 S034 S120

    0 114TIME (h)

    TC

    200

    12

    F3

    K3

    F3

    K3

    F3

    K3

    48 C

    47

    49

    128

    120

    D001:

    D002:

    D003:

    D004:

    D005:

    LAST M01 113 C

    62

    68

    70

    84

    D006:

    D007:

    D008:

    D009:

    D010:

    LAST M02 55 C

    60

    73

    78

    74

    D121:

    D122:

    D123:

    D124:

    D125:

    LAST M25

    12 VALID

    10

    11

    21

    20

    D001:

    D002:

    D003:

    D004:

    D005:

    DT% M01 20 VALID

    6

    11

    8

    15

    D006:

    D007:

    D008:

    D009:

    D010:

    DT% M02 17 VALID

    7

    0

    2

    1

    D121:

    D122:

    D123:

    D124:

    D125:

    DT% M25

    Tecla K3 - No Respondendo Canal 1

    Tecla K3 - Diferencial e Entradas Analgicas

    Tecla K3 - Trendings

    fluxo de telas rel modelo VZTteclas de funes

  • 32

    Z Y G G O T

    118

    Tecla K4 - Comando de FlashK4MENU F4

    K4MENU F4

    Tecla K4 - Dados e Parmetros

    K4MENU F4

    Tecla K4 - Menu de Programao

    Para Menu (Prxima Pagina)

    fluxo de telas rel modelo VZTteclas de funes

    DIG INPUTS TA1

    DIG INPUT 1DIG INPUT 2DIG INPUT 3DIG INPUT 4DIG INPUT 5DIG INPUT 6DIG INPUT 7DIG INPUT 8DIG INPUT 9DIG INPUT 10DIG INPUT 11DIG INPUT 12

    DATA TA1

    WARN / FAILS

    ACTIVE FAILS 1/2

    ACTIVE FAILS 2/2

    COMMUNICATION

    DIG INPUTSDIG OUTPUTSSTATISTICSINFO

    WARN / FAIL TA1

    ALARM ONTRIP ONFAIL ACTIVE

    ACTIVE FAILS 2/2 TA1

    EXT FAIL 1EXT FAIL 2EXT FAIL 3EXT FAIL 4EXT FAIL 5EXT FAIL 6EXT FAIL 7EXT FAIL 8ALRM ANALOG 1FAIL ANALOG 1ALRM ANALOG 2FAIL ANALOG 2ALRM ANALOG 3FAIL ANALOG 3ALRM ANALOG 4FAIL ANALOG 4

    ACTIVE FAILS 1/2 TA1

    SENSOR COMM FAILPROFIBUS FAILSENSOR NRTARGET HOTAIR HOTOPERATING HOUR

    COMMUNICATION TA1

    SENSOR COMM OKMODBUS ACTIVEMODBUS OKMODBUS ERROR

    DIG OUTPUTS TA1

    DIG OUTPUT 1DIG OUTPUT 2DIG OUTPUT 3DIG OUTPUT 4DIG OUTPUT 5DIG OUTPUT 6

    STATISTICS TA1

    OPER.:N ALARMSN TRIPS

    INFO TA1

    SOFTWARE VERSION:

    AIR GAGE:

    PLANT:

    LOCATION:

    PANEL:

    INIT DATE:

  • 33

    Z Y G G O T

    K4MENU F4

    Tecla K4 - Menu de Programao

    fluxo de telas rel modelo VZTteclas de funes

    SENSORS

    N SENSORS:BLINK SENSORS:GAGE AIR TEMP:

    BLOCK PROGRAMINGBLOCK 1BLOCK 2BLOCK 3BLOCK 4BLOCK 5DO BLOCK PROGRAMM

    BLOCK 1START:END:

    TARGET ALRM:TARGET TRIP:

    ANALOG INPUTSAI1 / NAME:AI2 / NAME:AI3 / NAMEAI4 / NAME:READ MODE:SCALE:

    TARGET ALRM LVS 01-10A1:A2:A3:A4:A5:A6:A7:A8:A9:A10:

    TARGET ALRM LVS 121-125A121:A122:A123:A124:A125:

    TARGET TRIP LVS 01-10T1:T2:T3:T4:T5:T6:T7:T8:T9:T10:

    TARGET TRIP LVS 121-125T121:T122:T123:T124:T125:

    TRENDING CONFIGSCALE:INDEX MODE:HMI RESET:INDEX 3A-7A:INDEX 3B-3B:INDEX 3C-3C:INDEX 8A-12A:INDEX 8B-12B:INDEX 8C-12C:

    CLEAR DATACLEAR HISTORYCLEAR STATISTICS

    TARGET ALARM LEVELSTARGET 01-10TARGET 11-20TARGET 21-30TARGET 31-40TARGET 41-50TARGET 51-60TARGET 61-70TARGET 71-80TARGET 81-90TARGET 91-100TARGET 101-120TARGET 121-125

    TARGET TRIP LEVELSTARGET 01-10TARGET 11-20TARGET 21-30TARGET 31-40TARGET 41-50TARGET 51-60TARGET 61-70TARGET 71-80TARGET 81-90TARGET 91-100TARGET 101-120TARGET 121-125

    PROTECTIONS 1/3NOT RESPONDINGTARGET ALARMTARGET TRIPAIR ALARMAIR TRIPOPERATING HOURSENSOR COMM FAILPROFIBUS FAILDIFFERENTIALGROUP

    NOT RESPONDINGACTION:AUX OUTPUT:

    AIR TRIPACTION:AUX OUTPUT:

    OPERATING HOURACTION:HOUR:AUX OUTPUT:

    DIFFERENTIALACTION:HI LEVEL:PERIOD:WARM UP:AUX OUTPUT:

    PROTECTIONS 2/3ANALOG 1 ALARMANALOG 1 TRIPANALOG 2 ALARMANALOG 2 TRIPANALOG 3 ALARMANALOG 3 TRIPANALOG 4 ALARMANALOG 4 TRIP

    ANALOG 1 ALARMACTION:LEVEL HIGH:AUX OUTPUT:

    ANALOG 4 TRIPACTION:LEVEL HIGH:AUX OUTPUT:

    PROTECTIONS 3/3EXTERNAL FAIL 1EXTERNAL FAIL 2EXTERNAL FAIL 3EXTERNAL FAIL 4EXTERNAL FAIL 5EXTERNAL FAIL 6EXTERNAL FAIL 7EXTERNAL FAIL 8

    EXTERNAL FAIL 1ACTION:TRIP DELAY:AUX OUTPUT:ASSIGN NAME:

    EXTERNAL FAIL 8ACTION:TRIP DELAY:AUX OUTPUT:ASSIGN NAME:

    MAIN MENURELAY CONFIGPARAMETERS CONFIGSENSORSBLOCK PROGRAMINGANALOG INPUTSMODBUS CONFIGSENSOR COMMUNICATION

    TARGET ALRM LVLSTARGET TRIP LVLSTRENDING CONFIGCLEAR DATA

    PROTECTIONS

    RELAY CONFIGLANGUAGE:SET R. TIME CLOCK:PROF. USE:PROF. NODE:PLANT:LOCATION:PANEL:INIT DATE:

    MODBUS CONFIGBAUD RATE:ADDRESS:PARITY:HANDSHAKE:TIMEOUT:STOP BITS:PORT MODE:MODBUS:

    SENSOR COMMUNICATION

    BAUD RATE:

    TIMEOUT:

    BLOCK 5START:END:

    TARGET ALRM:TARGET TRIP:

    PROTECTIONSPROTECTIONS 1

    PROTECTIONS 2

    PROTECTIONS 3

    SENSOR COMM FAILACTION:AUX OUTPUT:

    PROFIBUS FAILACTION:FAULT RESET:D.O. AUX:

    PARAMETERS CONFIGCENTIG/FAHRENHEIT:RESET ON FAIL:

    AIR ALRM LVL:AIR TRIP LVL:CALL SCR ON FAIL:CALL SCR ON ALM:RTN TO MAIN:MENU PASS:

    W/ FLASH ON:

    GROUP 1TRG ALRM ACT:TRG TRIP ACT:AIR ALRM ACT:AIR TRIP ACT:TRG ALRM AUX:TRG TRIP AUX:AIR ALRM AUX:AIR TRIP AUX:

    GROUP 5TRG ALRM ACT:TRG TRIP ACT:AIR ALRM ACT:AIR TRIP ACT:TRG ALRM AUX:TRG TRIP AUX:AIR ALRM AUX:AIR TRIP AUX:

    GROUPGROUP 1GROUP 2

    GROUP 4GROUP 3

    GROUP 5

  • Z Y G G O T

    34

    SUBMENU CONFIG RELENeste menu deve-se programar os parmetros relativos ao rel a saber: Linguagem: Pode-se escolher um entre 3 idiomas (ingls, portugus e espanhol). Set Relgio: Introduza a hora atual. Prof. Use: Escolha entre utilizar ou no a rede Profibus. Prof. Node: Defina o endereo do rel na rede Profibus. Para que a alterao de endereo Profibus seja vlida necessrio reiniciar o rel. Planta: Nome da planta onde o sistema est instalado. Local: rea da planta onde o sistema est instalado. Painel: Identificao do painel. Data In.: Data de inicio de operao.

    SUBMENU CONFIG. PARAM.Neste menu deve-se definir os parmetros relativos ao sistema a saber: Centig/Fahrenheit: Escolha o sistema de indicao de temperatura. Reset em falha: Se escolhido sim o rel aceita Reset de falhas mesmo com falha ativa, voltando a indicar a falha na prxima leitura. Nvel Alarme Ar: O nvel de alarme para temperatura do ar circundante o mesmo para todos os sensores do sistema. Caso ultrapassado a sada de alarme atuada. Nvel Trip Ar: O nvel de trip para temperaturas do ar circundante o mesmo para todos os sensores do sistema. Caso ultrapassado a sada de trip atuada. Chama Tela Falha: Se escolhido Sim, caso ocorra uma falha o rel chamar a tela de alarme. Caso escolhido no, ocorrer a indicao no LED FA da tela principal. O operador pode chamar as telas de alarme e histrico pela tecla F1. Chama Tela Alarme: Mesmas aes do item anterior mas para o caso de ocorrer um alarme. Retorna a Principal: Tempo para retorno automtico para as telas principais (chamadas tambm com K1). Programvel entre 0 e 999 s. se p r o g r a m a d o 0 n o r e t o r n a automaticamente para a tela principal. Menu senha: Insira a senha desejada. Caso seja 0000 o menu ser aberto sem pedido de senha.

    SUBMENU SENSORESNeste menu deve-se programar os parmetros relativos rede de sensores do sistema: N Sensores: Programe o nmero de sensores instalados (3 a 125). Flash Sensores: Nesta tela pode-se comandar que um sensor individual pisque o LED do seu corpo para ve r i f i cao de in teg r idade ou endereamento. Insira o nmero do sensor e confirme. Se inserido 0 todos os sensores piscaro o LED. Aps 4 segundos o LED deixar de piscar automaticamente. Seta temperatura de ar: Ajusta a leitura de temperatura de ar dos sensores. Esta operao opcional e deve ser executada com todos os sensores a mesma temperatura ambiente. Utilizar este comando sem conhecimento pode prejudicar as leituras. Os sensores j saem de fbrica calibrados adequadamente, portanto esta operao no necessria.

    SUBMENU PROG. BLOCOSNeste menu possvel definir e realizar a programao de blocos de sensores sequenciais. So permitidos at 5 blocos de sensores. Para cada bloco deve-se preencher os seguintes parmetros: Incio: Primeiro sensor do bloco. Fim: ltimo sensor do bloco. Ponto Alarme: Nvel de alarme. Ponto Trip: Nvel de Trip.Ao trmino da definio de blocos deve-se acessar Programa Blocos e confirmar a operao. Somente aps este ato os parmetros e blocos esto definidos.

    S U B M E N U E N T R A D A S ANALOGICASNeste menu deve-se programar os parmetros relativos as entradas analgicas 1 a 4: EA1/Nome: Nome da entrada 1. EA2/Nome: Nome da entrada 2. EA3/Nome: Nome da entrada 3. EA4/Nome: Nome da entrada 4. Modo leitura: % ou Temperatura. Caso escolhido % a indicao ser em percentagem do fundo de escala. Escala: Valor do fundo de escala.

    SUBMENU MODBUSNeste menu deve-se programar os parmetros relativos a comunicao Modbus, caso seja utilizada. Os parmetros disponveis so:

    Baud Rate: 9600, 19200 ou 38400 Endereo: 1 a 247 Paridade: None, Odd, Even Handshake : None, Xon/Xoff, CTS/RTS, MD/Half Duplex. Timeout: Tempo para indicao de erro de timeout (mx. 1000 s). Stop Bits: 1 ou 2 Modo Porta: RS232 ou Rs485. Modbus: Ativo ou Inativo. Se no for utilizar selecione Inativo.

    S U B M E N U S E N S O R COMMUNICATIONNeste menu deve-se programar os parmetros relativos a comunicao com os sensores: Baud Rate: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600 ou 115200 Timeout: 0,1 a 5,0 s

    SUBMENU NVEIS ALARME PONTOSNeste menu pode-se programar individualmente os nveis de alarme para cada ponto de medio: T1 a T125: Entre diretamente com o valor de temperatura.

    SUBMENU NVEIS TRIP PONTOSNeste menu pode-se programar individualmente os nveis de trip para cada ponto de medio: T1 a T125: Entre diretamente com o valor de temperatura.

    SUBMENU CONFIG TRENDINGNeste menu pode-se programar os parmetros correspondentes ao sistema de Trending, ou seja, a visualizao de curvas de temperatura obtidas em tempo real. Escala : L im i te super io r de temperatura para os grficos. Modo Index: Display ou Menu. No modo Display o operador escolhe os sensores que sero monitorados para as curvas na prpria tela de trending. Se escolhido Menu, os sensores utilizados nas curvas so definidos neste submenu. O modo Menu inibe o operador de limpar ou perder curvas j em aquisio. IHM Reset: Se escolhido Sim permite-se que as curvas sejam limpas ou resetadas mantendo por 3 segundos a tecla de RESET apertada.

    Menu de Programao - Tecla K10 (VZX) OU K4 (VZT)

    parametrizao pelo rel

  • Z Y G G O T

    35

    Index 3A-7A: Caso escolhido Modo Index como Menu, o nmero do sensor inserido aqui ser o utilizado para a curva A dos grficos 3 a 7. Cada grfico m o s t r a t r s t e m p e r a t u r a s simultaneamente. Index 3B-7B: Idem Index 3A-7A para curvas B. Index 3C-7C: Idem Index 3A-7A para curvas C. Index 8A-12A: Caso escolhido Modo Index como Menu, o nmero do sensor inserido aqui ser o utilizado para a curva A dos grficos 8 a 12. Cada grfico mostra trs temperaturas simultaneamente. Index 8B-12B: Idem Index 8A-12A para as curvas B. Index 8C-12C: Idem Index 8A-12A para as curvas C.

    SUBMENU LIMPA DADOSNeste menu pode-se limpar os dados de histria de defeitos e estatstica. Historia: Ser apresentada uma tela idntica a tela de histrico das telas pr incipais chamada pelo cone correspondente, porem com a opo de limpar cada item ou todos os itens. Para acessar estas opes pressione as teclas a direita do display. Estatstica: Neste menu pode-se limpar os dados de estatstica (nmero de leituras, nmero de alarmes e nmero de trips).

    SUBMENU PROTECESO menu de protees est dividido em trs partes. Protees 1 a 3.De maneira gera programa-se a ao tomada em caso de ocorrncia da falha e o rel auxiliar a ser ativado.Explicao geral das aes: Alarme: O rel de alarme atua e ocorre indicao no rel. Algumas protees no tem essa ao como opo. Trip: O rel de alarme e o rel de trip atuam e ocorre indicao no rel. Algumas protees no tem essa ao como opo. Log: O rel de alarme e de trip no atuam. Ocorre indicao no rel. Nada: Nenhuma ao tomada. A deteco da falha desativada.Em todas as falhas pode-se definir um rel auxiliar (Rels 3 a 6). Os rels de auxiliares podem estar associados a mais de uma falha. Caso a ao da falha seja NADA o rel auxiliar no atuar.

    SUBMENU PROTECES 1/3No primeiro submenu de protees esto as protees relativas a variao de temperatura, rede de comunicao dos sensores e falhas de comunicao.

    No Respondendo: Sensores no respondendo. Ao: Nada, Log, Alarme, Trip Sada Aux: nenhum, 3, 4, 5, 6

    Ponto Alarme: Ponto de medio atingiu nvel de alarme. Ao: Nada, Log, Alarme Sada Aux: nenhum, 3, 4, 5, 6

    Ponto Trip: Ponto de medio atingiu nvel de trip. Ao: Nada, Log, Trip Sada Aux: nenhum, 3, 4, 5, 6

    Ar Alarme: Temperatura do ar circundante atingiu nvel de alarme. Ao: Nada, Log, Alarme Sada Aux: nenhum, 3, 4, 5, 6

    Ar Trip: Temperatura do ar circundante atingiu nvel de trip. Ao: Nada, Log, Trip Sada Aux: nenhum, 3, 4, 5, 6

    Horas Operando: Tempo de operao do rel atingiu o limite. Ao: Nada, Log, Alarme Horas: 0.00 a 300.00 (x 1000 h) Sada Aux: nenhum, 3, 4, 5, 6

    Falha Comunicao Sensores: Erro na comunicao com rede de sensores. Ao: Nada, Log, Alarme Sada Aux: nenhum, 3, 4, 5, 6

    Profibus Falha: Falha na comunicao profibus. Ao: Nada, Log, Alarme, Trip Reset Falha: Manual/Auto. Se a

    falhar deixar de ocorrer o rel deve resetar automaticamente a indicao no rel e sada (Modo Auto) ou o operador deve pressionar o boto RESET (Modo Manual)

    Sada Aux: nenhum, 3, 4, 5, 6

    Diferencial: A falha diferencial analisa o aumento de temperatura (em %) que ocorreu no perodo. Caso o aumento de temperatura seja superior ao valor definido em Nvel Alto ser executada a ao definida. O rel possui uma entrada digital chamada Operao que indica a energizao do painel e incio da

    contagem de tempo. Para evitar variao devido ao aumento de temperatura inicial que existe ao se iniciar a operao do painel pode-se definir um tempo de Aquecimento, no qual a falha diferencial aguarda que o painel atinja sua temperatura normal de t r a b a l h o . A p s o p e r o d o d e aquecimento o valor de temperatura dos sensores armazenado e utilizado como referncia para o clculo de aumento no perodo. Ao final do perodo um novo valor de temperatura armazenado e utilizado como referncia para o prximo perodo. Ao: Nada, Log, Alarme, Trip Nvel Alto: 0 a 200% Perodo: 0 a 10000 h Aquecimento: 0 a 100 h Sada Aux: nenhum, 3, 4, 5, 6

    As indicaes de porcentagem de aumento medida para cada alvo so apresentadas com o acionamento duplo da tecla K7 (rel VZX) ou acionamento triplo da tecla K3 (rel VZT). As temperaturas de referncia para o c lcu lo percentua l podem ser verificadas atravs do acionamento triplo da tecla K7 (rel VZX); par o rel VZT os valores de referncia esto juntamente com os valores percentuais, utilize as teclas de navegao para se chegar aos valores de referncia. EXEMPLO: Perodo: 30 dias (720 h), Nivel alto: 20%. Primeira medio para um dos alvos = 50 C. Um ms aps medido para o mesmo alvo 55C. O aumento foi portanto de 10%, no ocorrendo falha. A temperatura de 55C passa a ser a nova referncia. No ms seguinte a temperatura medida = 70C deste modo o Delta T = ((70-55)/55)*100 = 27% e deste modo haver a atuao.

    Grupo: Para cada grupo esto disponveis as seguintes configuraes. Ao Alarme Ponto: Nada, Log,

    Alarme Ao Trip Ponto: Nada, Log, Trip Ao Alarme Ar: Nada, Log, Alarme Ao Trip Ar: Nada, Log, Trip Aux Alarme Ponto: Nada, 3, 4, 5, 6 Aux Trip Ponto: Nada, 3, 4, 5, 6 Aux Alarme Ar: Nada, 3, 4, 5, 6 Aux Trip Ar: Nada, 3, 4, 5, 6

    Menu de Programao - Tecla K10 (VZX) OU K4 (VZT)

    parametrizao pelo rel

  • Z Y G G O T

    36

    Menu de Programao - Tecla K10 (VZX) OU K4 (VZT)

    parametrizao pelo rel

    SUBMENU PROTECES 3/3Este submenu define as aes para as entradas digitais. Para cada uma das 8 entradas digitais de falhas pode-se definir a ao gerada, uma sada auxiliar, o tempo de retardo para deteco de acionamento da entrada e um nome para a entrada.

    Falha Externa 1 Ao: Nada, Log, Alarme, Trip Retardo Trip: 0 a 99,9 s Sada Aux: Nada, 3, 4, 5, 6. Nome: At 5 caracteres

    Falha Externa 2 Ao: Nada, Log, Alarme, Trip Retardo Trip: 0 a 99,9 s Sada Aux: Nada, 3, 4, 5, 6. Nome: At 5 caracteres

    Falha Externa 3 Ao: Nada, Log, Alarme, Trip Retardo Trip: 0 a 99,9 s Sada Aux: Nada, 3, 4, 5, 6. Nome: At 5 caracteres

    Falha Externa 4 Ao: Nada, Log, Alarme, Trip Retardo Trip: 0 a 99,9 s Sada Aux: Nada, 3, 4, 5, 6. Nome: At 5 caracteres

    Falha Externa 5 Ao: Nada, Log, Alarme, Trip Retardo Trip: 0 a 99,9 s Sada Aux: Nada, 3, 4, 5, 6. Nome: At 5 caracteres

    Falha Externa 6 Ao: Nada, Log, Alarme, Trip Retardo Trip: 0 a 99,9 s Sada Aux: Nada, 3, 4, 5, 6. Nome: At 5 caracteres

    Falha Externa 7 Ao: Nada, Log, Alarme, Trip Retardo Trip: 0 a 99,9 s Sada Aux: Nada, 3, 4, 5, 6. Nome: At 5 caracteres

    Falha Externa 8 Ao: Nada, Log, Alarme, Trip Retardo Trip: 0 a 99,9 s Sada Aux: Nada, 3, 4, 5, 6. Nome: At 5 caracteres

    SUBMENU PROTEES 2/3Este submenu trata das protees relativas as entradas analgicas. Para cada uma das entradas defini-se o nvel de alarme, nvel de trip e ao a ser tomada em cada

    Analog 1 Alarme: Definio de nvel de alarme e ao a ser tomada para entrada analgica 1. Ao: Nada, Log, Alarme Nvel Alto: 0 a 100% Sada Aux: nenhum, 3, 4, 5, 6

    Analog 1 Trip: Definio de nvel de trip e ao a ser tomada para entrada analgica 1. Ao: Nada, Log, Trip Nvel Alto: 0 a 100% Sada Aux: nenhum, 3, 4, 5, 6

    Analog 2 Alarme: Definio de nvel de alarme e ao a ser tomada para entrada analgica 2. Ao: Nada, Log, Alarme Nvel Alto: 0 a 100% Sada Aux: nenhum, 3, 4, 5, 6

    Analog 2 Trip: Definio de nvel de trip e ao a ser tomada para entrada analgica 2. Ao: Nada, Log, Trip Nvel Alto: 0 a 100% Sada Aux: nenhum, 3, 4, 5, 6

    Analog 3 Alarme: Definio de nvel de alarme e ao a ser tomada para entrada analgica 3. Ao: Nada, Log, Alarme Nvel Alto: 0 a 100% Sada Aux: nenhum, 3, 4, 5, 6

    Analog 3 Trip: Definio de nvel de trip e ao a ser tomada para entrada analgica 3. Ao: Nada, Log, Trip Nvel Alto: 0 a 100% Sada Aux: nenhum, 3, 4, 5, 6

    Analog 4 Alarme: Definio de nvel de alarme e ao a ser tomada para entrada analgica 4. Ao: Nada, Log, Alarme Nvel Alto: 0 a 100% Sada Aux: nenhum, 3, 4, 5, 6

    Analog 4 Trip: Definio de nvel de trip e ao a ser tomada para entrada analgica 4. Ao: Nada, Log, Trip Nvel Alto: 0 a 100% Sada Aux: nenhum, 3, 4, 5, 6

  • Z Y G G O T

    37

    parametrizao pelo Computador

    ZYGGOT SUPERGER

    Zyggot SuperGer um software de configurao e supervisrio para toda a famlia Zyggot. Atualmente o software realiza a parametrizao dos rels do sistema Zyggot Temperatura. Em verses futuras ele tambm ir realizar a programao dos sensores do sistema temperatura e realizar a configurao para o sistema Zyggot Arco.O software est disponvel gratuitamente no CD que acompanha o rel ou atravs do site da Varixx (http://www.varixx.com.br). Ao lado apresentada a tela principal do programa.Apesar de ser possvel realizar a parametrizao do rel diretamente no mesmo, utilizar um software possui vantagens como armazenar as configuraes do rel em um arquivo no computador e carregar configuraes pr-definidas, diminuindo o tempo de parametrizao.

    O primeiro passo no software escolher na tela de configurao do sistema o idioma e o modo de trabalho: atualmente s est disponvel o modo Configurador.Uma vez escolhido o modo Configurador escolha o rel do sistema Zyggot Tubular / BT.

    O prximo passo realizar a conexo com o rel. Para tanto ajuste os valores da comunicao Modbus no rel e ative o mesmo no modo RS-232. Para detalhes sobre como ativar o Modbus consulte a seo do menu de programao.Utilize um cabo RS-232 / RJ45 para fazer a conexo entre o rel e um computador. No programa Zyggot SuperGer preencha na aba de conexo as informaes de porta serial a utilizar e informaes do Modbus como endereo do rel, Baud Rate, paridade e timeout. Ao final pressione o boto Conectar.

    Quando a conexo ocorrer a lmpada de conectado se acende.Se o caixa de leitura inicial estiver marcada, logo aps a conexo com o rel todos os parmetros do rel sero transferidos para o programa. Ao trmino exibida uma mensagem de sucesso.Utilize os botes de salvar e abrir para salvar as informaes de um rel em um arquivo no computador e descarregar a mesma informao em outros rels.

    Para que os dados sejam transmitidos para o rel necessrio pressionar o boto enviar.O boto Receber fora uma leitura de todos os dados do rel.

    O programa registra em histrico todas as atividades que ocorreram.O novo boto de atualizao permite que voc tenha sempre o software mais atualizado com apenas um clique do mouse.

  • Z Y G G O T

    38

    configurao do sensor

    SOFTWARE ZYGGOT GERENCIADOR

    Zyggot Gerenciador um software configurador que realiza o endereamento e teste dos sensores. O software est disponvel gratuitamente no CD que acompanha o rel ou atravs do site da Varixx (http://www.varixx.com.br). A figura ao lado apresenta a tela principal do software.

    O programa permite verificar e definir parmetros importantes antes da utilizao do sensor na rede.Atravs dele define-se o endereo do sensor e outros parmetros de rede, a emissividade do alvo considerado pelo sensor e habilitao do resistor de terminao.

    Nota: Quando utilizando fita unidex (emissividade conhecida e constante ao longo dos anos) deve-se utilizar o valor de emissividade 0,95.

    A interface amigvel permite a visualizao da temperatura do alvo e do corpo do sensor de diversas maneiras:

    Atravs de um grfico possvel verificar a temperatura medida no tempo. Os finais de escala podem ser alterados com um clique do mouse.

    As leituras de temperatura tambm so indicadas em forma numrica.

    Atravs de um marcador analgica. O valor de fundo de escala pode ser alterado.

    Pode-se tambm enviar um comando para que o LED do sensor pisque, do mesmo modo que feito no rel para identificao de sensores na rede.

    Janela principal do software Gerenciador

    ! CAUTION

    No conectar o sensor ao PC enquanto a outra porta mini USB estiver conectada na rede

    OK!

    SEMPRE enderear um sensor por vez

    NUNCA conectar dois sensores simultaneamente ao PC

  • Z Y G G O T

    39

    ENDEREAMENTO DOS SENSORES

    Para que no haja o comprometimento do bom funcionamento do sistema, primordial que sejam seguidas todas as instrues de configurao dos sensores, que sero expostas adiante.Deve-se executar a configurao de cada sensor antes mesmo de instal-los mecanicamente.

    A) Instale o Zyggot Gerenciador no computador e execute-o na sequncia;

    B) Conecte o cabo configurador (fornecido juntamente com a Maleta de Instalao e Manuteno Zyggot Temperatura) a uma porta USB do PC e a uma das portas mini USB do sensor.

    C) O programa detecta automaticamente a porta referente ao sensor. Caso deseje tambm possvel selecionar manualmente a porta do sensor. Para tanto marque a caixa Conexo Manual, selecione a porta COM referente ao sensor e pressione Conectar. Se no houver sensor conectado a porta selecionada uma mensagem de erro ir aparecer.

    D) Ao conectar o sensor, o programa reconhecer o mesmo e indicar automaticamente o tipo de protocolo de comunicao com o sensor (Modbus, CanOpen) e indicar por um boto verde que o mesmo est conectado.

    E) Defina o endereo do sensor (1 a 125) e escolha se o resistor de terminao ser ativado ou no. Outros parmetros da comunicao serial tambm esto disponveis para configurao. Por padro todos os sensores saem de fbrica com endereo 1 e parmetros de rede para comunicao com rel Zyggot Temperatura. Ao trmino pressione o boto Enviar.

    Obs.: Cada sensor deve possuir um endereo exclusivo na rede (de 1 a 125). Quando mais de um sensor possui o mesmo endereo na rede ocorre conflito e a no-operao do sistema.

    Nota: As redes de sensores cabeados devem possuir dois resistores de terminao: um no primeiro sensor da rede e outro no ltimo. Pode-se utilizar um resistor externo ou ativar internamente o resistor de terminao dos sensores durante a configurao. Se outros resistores forem adicionados rede pode ocorrer instabilidade da rede e no funcionamento. A Varixx fornece resistores de terminao fsicos para utilizao em suas redes de sensores.

    F) Insira a emissividade do alvo e pressione o boto Enviar.

    Nota: Quando utilizando fita unidex (emissividade conhecida e constante ao longo dos anos) deve-se utilizar o valor de emissividade 0,95 (padro).

    G) Anote o endereo do sensor, para ter um mapa da localizao do mesmo no painel ou local de instalao. Este o endereo que ser mostrado na tela do rel referente a este sensor, para sua correta identificao.

    Janela principal do software Gerenciador

    configurao do sensor

  • Z Y G G O T

    40

    No programa possvel visualizar e ajustar os nveis de alarme e trip de cada sensor. Visualizar a temperatura de todos os sensores e verificar o estado individual de cada sensor.

    software supervisrio

    ZYGGOT SUPERVISRIO

    Zyggot Supervisrio um software supervisrio que realiza comunicao com o rel e apresenta as leituras dos sensores na tela do computador igual a um sistema supervisrio. O software est disponvel gratuitamente no CD que acompanha o rel ou atravs do site da Varixx (http://www.varixx.com.br). A figura abaixo apresenta algumas telas do programa.

  • Z Y G G O T

    41

    VERIFICAO DE ALARMES E HISTRICO DE FALHASAs teclas F1 e F2 (modelo VZX) ou K0 pressionada pela terceira vez (modelo VZT) chamam as telas de alarme e histrico de falhas. De qualquer das telas pode-se utilizar as teclas de navegao para verificar os alarmes a t i v o s , o s e v e n t o s / h i s t r i c o s registrados, informaes sobre a verso do rel e tempo total de operao, informaes sobre a planta, painel e data de instalao alm de verificao de data e hora do relgio de tempo real.

    Estando na tela de Alarme, indicada por um despertador e fundo preto, pressione ENTER para ver detalhes de cada alarme ocorrido e em seguida pressione qualquer das teclas de direo mostradas acima para que surja um menu com as possibilidades a seguir: Ack e Ack All para reconhecer um ou todos os alarmes e Clr e Clr All para limpar um ou todos os alarmes alem de Esc para sair do submenu de opes.Estando na tela de histrico pode-se observar at 125 memrias de eventos ocorridos, inclusive reconhecimento de falhas. Neste menu no se pode limpar os itens. A limpeza do histrico real izada atravs do menu de programao.

    F2F1 lmpadas) de erro de comunicao, sensores no respondendo, falha por diferencial de temperatura, alarme e trip ativo. Tambm indica caso todos os sensores estejam operando de forma correta.A Tela 6 mostra condies da comunicao Modbus. Indica se o Modbus est ativado, se h erro ou se est funcionando corretamente. Em uma caixa indica tambm o status de mensagem vlido ou erro. A Tela 7 mostra os estados das 12 entradas digitais.A Tela 8 mostra os estados das 6 sadas digitais.A Tela 9 mostra se foi atingido algum nvel de temperatura de Alarme ou de Trip. Na tela apresentada de forma independente as indicaes de alarme de ponto, trip de ponto, alarme de ar e trip de ar, alm de indicar ocorrncia de trip por elevao diferencial de temperatura de alvos.A Tela 10 apresenta atuao de alarme/trip por grupo. As indicaes esto separadas por grupo e se a atuao ocorreu devido a limite de temperatura de ponto ou de ar.A Tela 11 apresenta informaes detalhadas sobre a comunicao na rede de sensores.A Tela 12 apresenta informaes sobre a comunicao Profibus, apresentando o endereo do rel na rede e o status da mensagem em cdigo binrio.A Tela 13 apresenta os valores percentuais das 04 entradas analgicas.

    operao

    /F0SYS

    AFGHT

    MTDGI

    CVFYD

    ADSCR

    HT

    GIYDo

    VERIFICAO DE LEITURAS E DADOS GERAISA tecla K1 no modelo VZX ou K0 no modelo VZT, chama a tela principal 1. Usando-se as teclas de navegao pode-se navegar pelas 13 telas deste grupo.Na parte inferior de cada tela temos as seguintes informaes, indicadas em forma de lmpadas de sinalizao (ativa quando brancas e inativas quando pretas): FA: Falha ativa. AIR: Sobretemperatura no corpo do sensor/Ar. TA: Sobretemperatura no Alvo. NR: Sensores no respondendo. AL: Alarme atuado (rel de alarme) TR: Trip atuado (rel de trip)

    A Tela 1 mostra a maior temperatura de alvo e a maior temperatura de corpo do sensor (Ar) alm do nmero de sensores respondendo e no respondendo.A Tela 2 mostra indica se uma leitura est sendo realizada e o nmero do sensor que o rel est lendo.A Tela 3 mostra o nmero de sensores programados e o nmero de sensores respondendo (OK).A Tela 4 mostra o nmero total de alarmes e nmero total de trips que ocorreram. Estas informaes podem ser reiniciadas dentro do menu de programao.A Tela 5 mostra indicaes (atravs de

    QZ1

    68

    131 /F0SYS

    AFGHT

    MTDGI

    CVFYD

    ADSCR

    HT

    GIYDo

  • Z Y G G O T

    42

    VERIFICAO DE LEITURAS DE TEMPERATURA DE ALVO E CORPO (AR) DE TODOS OS SENSORES.A tecla K3 (modelo VZX) ou K1 (modelo VZT) chama as telas de leitura de todas as temperaturas de alvo e corpo dos sensores.

    Modelo VZX:A primeira vez que a tecla K3 for pressionada, tem-se as leituras dos pontos. Na segunda vez as leituras de corpo (ar) dos sensores. Utilize as teclas de navegao para visualizar em 25 telas a temperaturas dos 125 sensores.

    Modelo VZT:A terceira vez que a tecla K1 for pressionada, tem-se as leituras dos pontos. Na Quarta vez as leituras de corpo (ar) dos sensores. Utilize as teclas de navegao para visualizar em 25 telas a temperatura dos 125 sensores.

    Caso a temperatura medida seja superior ao nvel de alarme programado o ndice correspondente (A001 a A125 / T001 a T125) ir piscar e caso a temperatura medida seja superior ao nvel de trip programado a indicao de temperatura e tambm o ndice iro piscar.

    DEF3

    T003 70 T005 92

    T002 45 T004 88

    T001 68TARG

    CCT01

    operao

    VERIFICAO DE LEITURAS DE TEMPERATURA DE ALVOS E CORPOS (AR) SELECIONADOS.Alem da visualizao de temperaturas de corpo e alvo de todos os sensores pode-se programar 20 alvos e 20 corpos de sensores (ar) para visualizao rpida.A tecla K2 (modelo VZX) ou K1 (modelo VZT) chama as telas de verificao de leituras de alvo e de corpo do sensor (ar) selecionados.Na primeira pressionada sobre o boto, tem-se a tela de temperaturas de alvos selecionados e ao se pressionar uma segunda vez tem-se a tela de temperaturas de corpos selecionados. Em cada tela so exibidas as temperaturas de dois sensores. Utilize as teclas de navegao para visualizar em 10 telas as 20 temperaturas configuradas.

    PARA PROGRAMARModelo VZX:Selecione um dos dois campos com as teclas de direo para cima e para baixo. O campo selecionado fica com uma linha pontilhada em volta, pressione Enter e insira o nmero do sensor. No necessrio seguir qualquer ordem numrica.

    Modelo VZT:Clique sobre o campo desejvel e insira (atravs do teclado touch) o nmero do sensor desejado.

    Caso a temperatura medida seja superior ao nvel de alarme programado o ndice ira piscar e caso a temperatura medida seja superior ao nvel de trip programado a indicao de temperatura e tambm o ndice iro piscar.

    ABC2

    S125: 68

    S089: 131

    SELECT TARG ST01/F1

    S125: 68

    S089: 131

    SELECT TARG ST01 /F1

    S125: 68

    S089: 131

    SELECT TARG ST01

    VE