Variable-speed drives · 2015. 5. 18. · Variable speed drives for a broad range of applications...
Transcript of Variable-speed drives · 2015. 5. 18. · Variable speed drives for a broad range of applications...
-
IE2 motors for use on a
frequency converter
www.vem-group.com
Variable-speed drives
www.vem-group.com
-
IE2
mot
ors
for
use
on a
freq
uenc
y co
nver
ter
IE2 motors for use on a frequency converterVariable speed drives for a broad range of applications
Standard insulation For motors with standard insulation, the permissible peak voltages at the connecting terminals must not exceed the limit curve shown in Fig. 7 of DIN VDE 0530-17:2007-12 (IEC/TS 60034-17:2006). If the permissible peak voltage is not observed, it is either necessary to provide a filter at the converter output or use a motor with enhanced insulation.
Enhanced winding insulation Operation on a frequency converterup to 500 V without filter
Motors of the design series IE2-WU.. possess enhanc-ed winding insulation to permit operation of the motor on frequency converters for mains voltages up to 500 V without filter. From IEC size 315, insulated bearings are used on the non-drive side as standard, and the insu-lation of the PTC thermistors is adapted to the higher withstand voltage of the winding.
Subject to limitation of the impulse voltages to the cor-responding maximum permissible values, motors of the design series IE2-WU.. are also well suited for operation on 690 V converters.
Sizes 80 to 400Power range 0.75 – 355 kW (Outputs for size 400 by request)Efficiency class IE2 acc. to IEC/EN 60034-30, valid for mains operation and continuous duty S1 Type of protection IP 55 acc. to IEC/EN 60034-5, higher types of protection as optionType of construction IM B3, IM B35, IM B5, IM B14, IM B34 and derived types acc. to IEC/EN 60034-7Duty type S1/S8, S1/S9 acc. to IEC/EN 60034-1Type of cooling IC 411 (K..R) or IC 416 (K..F) acc. to IEC/EN 60034-6
Series IE2-WU.. for operation on a 500 V converter without filter
-
Please refer to our catalogues for technical details. The catalogues are available in printed or in digital version on DVD. They are also available in the internet.
IE2
mot
ors
for
use
on a
freq
uenc
y co
nver
ter
Size Rated output P (kW) Series IE2-WU.. Types of cooling IC 411 and IC 416, without filter up to 500 V 2-pole 4-pole 6-pole 8-pole* 3000 1500 1000 750 rpm80 K 0.75 - - -80 G 1.1 0.75 - -90 S 1.5 1.1 0.75 -90 L 2.2 1.5 1.1 -100 L 3 2.2 - 0.75100 LX - 3 1.5 1.1112 M. 4 4 2.2 1.5132 S.T 5.5 - - -132 S 5.5 5.5 3 2.2132 SX 7.5 - - -132 M - 7.5 4 3132 MX - - 5.5 -160 M 11 11 7.5 4160 MX 15 - 5.5160 L 18.5 15 11 7.5180 M 22 18.5 - -180 L - 22 15 11200 L 25 30 18.5 15200 LX 37 - 22 -225 S - 37 - 18.5225 M 45 45 30 22250 M 55 55 37 30280 S 74 75 45 37280 M 87 90 55 45315 S 110 110 75 55315 M 132 132 90 75315 MX 160 160 110 90315 MY 192 200 132 110315 L 220 250 160 132315 LX 270 285 185 145355 MY 315 315 200 160355 M 330 355 250 200355 MX - - 300 215355 LY - - 315 230
Outputs for size 400 by request
* without IE-marking
IE2 motors are suitable for the most varied applications also in converter-fed operation.
-
www.vem-group.com
© 2015 KOMMUNIKATION SCHNELL GmbH
VEM/05-015.2 E/0315 Printed in Germany. Subject to change.
For detailed information please visit our website.
VEM Holding GmbH
Pirnaer Landstraße 176 D-01257 Dresden
Phone: +49 351 208-0 Fax: +49 351 208-1028
VEM Sales
Low voltage
Phone: +49 3943 68-0 E-Mail: [email protected]
High voltage
Phone: +49 351 208-0 E-Mail: [email protected]
Drive systems