VANISHPOINT Catalog Number Description Safety by design ... · 511 Lobo Lane Little Elm, Texas...
Transcript of VANISHPOINT Catalog Number Description Safety by design ... · 511 Lobo Lane Little Elm, Texas...
![Page 1: VANISHPOINT Catalog Number Description Safety by design ... · 511 Lobo Lane Little Elm, Texas 75068-5295 USA Tel.: (972) 294-1770 Fax: (972) 294-4400 Toll Free: 1-888-703-1010 rtisales@vanishpoint.com](https://reader034.fdocuments.us/reader034/viewer/2022043011/5fa76125af54f00abc748b68/html5/thumbnails/1.jpg)
Other Available Safety Products
Patient Safe® Syringe
VanishPoint® Syringe
VanishPoint® Blood Collection Set
VanishPoint® IV Catheter
BLOOD COLLECTION TUBE HOLDER
VANISHPOINT®
Safety by design
* CDC (1997). Evaluation of safety devices for preventing percutaneous injuries among health-care workers during phlebotomy procedures_Minneapolis-St. Paul, New York City, and San Francisco, 1993-1995. MMWR 46(2):21-25.
Catalog Number Description
VanishPoint® blood collection products22701 VanishPoint blood collection tube holder 250 units per case22711 VanishPoint small diameter tube adapter 25 units per box
Safety mechanism is built into the tube holder
Studies show that most needlestick injuries occur within
seconds after needles are removed from patients*
Safety mechanism is activated BEFORE needle is removed, effectively reducing exposure
to contaminated sharps
Needle retracts directly from patient into tube holder,
protecting users from both ends of contaminated needle
Prevents recapping and needle removal
Single-use holder complies with safety regulations and
prevents cross contamination
Safe for you and your patients
© 2008, 2016 Retractable Technologies, Inc. All rights reserved.M006 REV.8 EN, JUL 2016© 2008, 2016 Retractable Technologies, Inc. All rights reserved.M006 REV.8 EN, JUL 2016
511 Lobo LaneLittle Elm, Texas 75068-5295 USA
Tel.: (972) 294-1770Fax: (972) 294-4400
Toll Free: [email protected]
511 Lobo LaneLittle Elm, Texas 75068-5295 USA
Tel.: (972) 294-1770Fax: (972) 294-4400
Toll Free: [email protected]
The New Standard for Safety®
UNCOMPROMISINGSAFETY FOR CLINICIANS AND PATIENTS
© 2008, 2016 Retractable Technologies, Inc.All rights reserved. M006 REV.8 EN, JUL 2016
![Page 2: VANISHPOINT Catalog Number Description Safety by design ... · 511 Lobo Lane Little Elm, Texas 75068-5295 USA Tel.: (972) 294-1770 Fax: (972) 294-4400 Toll Free: 1-888-703-1010 rtisales@vanishpoint.com](https://reader034.fdocuments.us/reader034/viewer/2022043011/5fa76125af54f00abc748b68/html5/thumbnails/2.jpg)
1234
the VANISHPOINT®
ADVANTAGEDesigned for Clinicianand Patient Safety
Securely thread multiplesample blood collectionneedle into tube holder.
Perform venipuncture perprotocol of institution.
Once last tube has beenremoved and needle is stillin patient's vein, close endcap. Needle automaticallyretracts out of patient's veininto tube holder.
Dispose of VanishPoint® tube holder in an appropriate sharps container.
End cap is flexible and can beeasily closed from any position
Clear, blue tube holder allows easyvisualization of tube and blood return
Compatible with standard, multiplesample blood collection needles
Needle is retracted directly frompatient, virtually eliminatingexposure to contaminated needle
Protects users from both endsof contaminated needle
Allows users to keep both handsbehind needle when activating
safety mechanism
flexible and can bed from any position
Clear, blue tube holder allows easyvisualization of tube and blood return
Compatible with standasample blood collectio