Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact...

104
Clever heat storage! Product catalogue 2017 Innovative storage tank and container solutions Valid from 01 July 2017

Transcript of Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact...

Page 1: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

Clever heat storage!

Product catalogue 2017Innovative storage tank and container solutionsValid from 01 July 2017

Page 2: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

2 I www.huch.com

enamelled domestic water storage tanks until 5.000 Litresmax. height 3.200 mmmax. diameter 1.500 mm

Pressure and pressurized containers from 30 Litresmin. height 500 mmmin. diameter 300 mm

Buffer storage tanks until 25.000 Litres max. height ≈ 6.000 mmmax. diameter 2.400 mm

» Custom-made storage tanks "made in germany"

In batch and individual unit production! Our know-how enables us to respond to customer requests in a highly individual manner. Just ask us, we will look for solutions together.

Detailed information from page 82 upwards.

Page 3: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 3

Overview of our storage tanks - the right solution for every heating system 04

New in the assortment 06

Quality features 08

Certificates / Qualifications 09

General installation instructions 10

Dimensioning of buffer storage tanks and domestic water storage tanks 12

Solar storage tanks ESS-PU Solar storage tank, rigid foam 16

SSH Solar storage tank 18

SSH-Plus Solar storage tank 20

Domestic water storage tanks EBS-PU Domestic water storage tank, rigid foam 24

BS Domestic water storage tank 26

HLS-Plus High-performance storage tank 28

PSB Buffer storage tank 30

HSO Domestic water storage tank, rigid foam 32

WWS-TS Domestic water storage tank, vertical, rigid foam 34

Buffer storage tanks SPSX / SPSX-F Stratified buffer storage tank with stratification system 38

SPSX-G / SPSX-2G Stratified buffer storage tank with bare-tube heat exchangers 40

PSX / PSX-F Buffer storage tank 42

PSX-GWT Buffer storage tank with bare-tube heat exchangers 44

Systems for Huch storage tanks

FRIWA Fresh water stations 48

EZ Energy control centre 50

VARIO S / VARIO W Heat pumps 52

Combined storage tanks SKSE / SKSV Combined storage tank with internal tank 58

SKSW Combined storage tank with corrugated stainless steel pipe (5 / 8 m²) 60

SKSP Buffer storage tank 62

WKS Combined storage tank with corrugated stainless steel pipe (5 m²) 64

Stainless steel storage tank HSS Strainless steel solar storage tank, 8 bar 68

HBS Strainless steel domestic water storage tank, 8 bar 70

HPS Strainless steel buffer storage tank, 8 bar 72

Pressure vessel DWK Pressurised water storage, vertical / horizontal design 76

DLB Compressed ait tank, vertical / horizontal design 78

Other tanks AG Expansion vessels 80

FK Filter boiler 81

Custom-made tanks Buffer storage tanks, domestic water storage tanks, cold water buffer storage tanks (KWP) 82

Calculation assist / dimension table 84

Accessories 90

Fire bowls & accessories 98

Important notes regarding this catalogue / abbreviations 102

General terms and conditions 103

Contact persons 104

All prices are non-binding end customer prices and do not include value-added tax.

Table of Contents

Page 4: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

4 I www.huch.com

Solar storage tank Domestic water storage tank Buffer storage tank Combined storage tank(Domestic water storage tank + Buffer storage tank) Stainless steel storage tank Other tanks Custom-made tanks

ESS-PU SSH SSH-Plus EBS-PU BS HLS-Plus PSB HSO WWS-TS SPSX / SPSX-F

SPSX-G/SPSX-2G

PSX / PSX-F PSX-GWT SKSE / SKSV /

SKSW / SKSP WKS HSS HBS HPS DWK DLB Custom-made tanks

We produce your customised tank with individual dimensions:

» Buffer storage tank from 200 to 25.000 Litres

» Cold water buffer storage tank from 300 to 25.000 Litres

» enamelled storage tanks to 5.000 Litres

» Filter boiler

» Expansion vessel

» Mobile mixed tank

» Baking oven tank

» Tanks for combined heat & power plants

» Pressure tanks for braking systems

» Tanks for compressors

» Oil collecting vessels

» Tanks for railway engineering

... and much more!

Send us your enquiry.

More information from p. 82 upwards.

Bare-tube heat exchanger Bare-tube heat exchanger Bare-tube heat exchanger Bare-tube heat exchanger Bare-tube heat exchanger

2 2 3 1 1 1 - 2 0 1 1 0 1 - 2 0 1 0 - 2 0 - 2 2 1 0 - -

Compressive strenght Compressive strenght Compressive strenght Compressive strenght Compressive strenght

10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 3 bar 3 bar 3 bar 3 bar 3 bar 3 bar 8 bar 8 bar 8 bar 4/6/10 bar 11/16 bar

Insulation HS = PU rigid foam Insulation HS = PU rigid foam Insulation Insulation Insulation HS = PU rigid foam

HS Fleece Fleece HS Fleece Fleece Fleece HS HS Fleece Fleece Fleece Fleece Fleece Fleece HS / Fleece HS / Fleece HS / Fleece - -

Contents Contents Contents Contents Contents

200 lto

500 l

300 lto

2000 l

350 lto

800 l

120 lto

500 l

120 lto

2000 l

150 lto

800 l

200 lto

2000 l

120 lto

150 l

120 lto

200 l

200 l to

3000 l

500 lto

2000 l

200 l to

3000 l

500 lto

2000 l

600 lto

1500 l

600 lto

1500 l

200 lto

2000 l

150 lto

2000 l

150 lto

2000 l

60 l to

3000 l

40 lto

1000 l

Standard energy efficiency class for storage tanks up to and including 500 litres

The suitable storage tank for your complete system Note: Special solutions such as the combination of various heat sources also allow for other applications.

■ ■ ■ ■ ■ ■ ■ ■ ■ Biogas plant / Biomass plant

■ ■ ■ ■ ■ ■ ■ ■ ■ Combined heat and power plant

■ ■ ■ ■ ■ ■ ■ ■ ■ Wood chip- / Wood burning plant

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Condensing power plant

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Gas plant

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Oil heating plant

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Pellet heating

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Solar heating plant

■ ■ ■ (except for SKSP) Heating pump system

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Direct heating system

Detailed product information and technical data are provided on the following pages:

page 16 page 18 page 20 page 24 page 26 page 28 page 30 page 32 page 34 page 38 page 40 page 42 page 44 page 58 page 64 page 68 page 70 page 72 page 76 p. 78

Overview of our storage tanks - the right solution for every heating system

Page 5: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 5

Solar storage tank Domestic water storage tank Buffer storage tank Combined storage tank(Domestic water storage tank + Buffer storage tank) Stainless steel storage tank Other tanks Custom-made tanks

ESS-PU SSH SSH-Plus EBS-PU BS HLS-Plus PSB HSO WWS-TS SPSX / SPSX-F

SPSX-G/SPSX-2G

PSX / PSX-F PSX-GWT SKSE / SKSV /

SKSW / SKSP WKS HSS HBS HPS DWK DLB Custom-made tanks

We produce your customised tank with individual dimensions:

» Buffer storage tank from 200 to 25.000 Litres

» Cold water buffer storage tank from 300 to 25.000 Litres

» enamelled storage tanks to 5.000 Litres

» Filter boiler

» Expansion vessel

» Mobile mixed tank

» Baking oven tank

» Tanks for combined heat & power plants

» Pressure tanks for braking systems

» Tanks for compressors

» Oil collecting vessels

» Tanks for railway engineering

... and much more!

Send us your enquiry.

More information from p. 82 upwards.

Bare-tube heat exchanger Bare-tube heat exchanger Bare-tube heat exchanger Bare-tube heat exchanger Bare-tube heat exchanger

2 2 3 1 1 1 - 2 0 1 1 0 1 - 2 0 1 0 - 2 0 - 2 2 1 0 - -

Compressive strenght Compressive strenght Compressive strenght Compressive strenght Compressive strenght

10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 3 bar 3 bar 3 bar 3 bar 3 bar 3 bar 8 bar 8 bar 8 bar 4/6/10 bar 11/16 bar

Insulation HS = PU rigid foam Insulation HS = PU rigid foam Insulation Insulation Insulation HS = PU rigid foam

HS Fleece Fleece HS Fleece Fleece Fleece HS HS Fleece Fleece Fleece Fleece Fleece Fleece HS / Fleece HS / Fleece HS / Fleece - -

Contents Contents Contents Contents Contents

200 lto

500 l

300 lto

2000 l

350 lto

800 l

120 lto

500 l

120 lto

2000 l

150 lto

800 l

200 lto

2000 l

120 lto

150 l

120 lto

200 l

200 l to

3000 l

500 lto

2000 l

200 l to

3000 l

500 lto

2000 l

600 lto

1500 l

600 lto

1500 l

200 lto

2000 l

150 lto

2000 l

150 lto

2000 l

60 l to

3000 l

40 lto

1000 l

Standard energy efficiency class for storage tanks up to and including 500 litres

The suitable storage tank for your complete system Note: Special solutions such as the combination of various heat sources also allow for other applications.

■ ■ ■ ■ ■ ■ ■ ■ ■ Biogas plant / Biomass plant

■ ■ ■ ■ ■ ■ ■ ■ ■ Combined heat and power plant

■ ■ ■ ■ ■ ■ ■ ■ ■ Wood chip- / Wood burning plant

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Condensing power plant

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Gas plant

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Oil heating plant

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Pellet heating

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Solar heating plant

■ ■ ■ (except for SKSP) Heating pump system

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Direct heating system

Detailed product information and technical data are provided on the following pages:

page 16 page 18 page 20 page 24 page 26 page 28 page 30 page 32 page 34 page 38 page 40 page 42 page 44 page 58 page 64 page 68 page 70 page 72 page 76 p. 78

Overview of our storage tanks - the right solution for every heating system

Fig. SKSE /SKSVFig. SKSW

HLV

nur bei 1000 L nur bei 1000 L

Lasche

NEW

NEW

NEW

Page 6: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

6 I www.huch.com

New at the assortment

Optimized stainless steel storage tank HSS / HBS / HPSTop quality at a minimum price

Polyline© fleece insulation - now with zip

Heat pump VARIO S & VARIO W with electr. control

» Optimum value for money

» Energy efficiency class B up to 500 litres

» Up to 500 litres PU rigid foam + Sky-coating

» Upwards of 800 litres Polyline© fleece insulation

» As a solar, domestic water & buffer storage tank

» Easy-to-get-at zip

» Stable double seam

» Incl. base and lid insulation

» Fire protection class B2

» Easy to install

» Slotted fleece

More information as of Page 68.

More information as of Page 52.

» Low investment costs compared to brine/water and water/water systems

» Easy and quick to install

» Can be set up in the smallest of spaces

» Can also be installed with hot water tanks already in place

Convincing advantages

Convincing advantages

B

Did you know that......even cool air has a lot of energy. This is made use of by the compact hot water heat pump and represents an optimum energetic support for many heating systems - whether in newer or older housing. It generates the hot water (domestic water) without the assistance of the boiler. The pump extracts the heat energy needed to heat the warm water up to 55°C from the surrounding air (upwards of a +7° ambient temperature).

Page 7: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 7

Fresh water station Tacotherm Fresh Mega Connect and Fresh Mega2 X

Custom-made storage tanks - for even more scope

» Easy and quick installation at the buffer storage tank

» For domestic water heating based on the flow-through principle

» Hygienically correct

» Available with or without circulation

» Various filling rates

» For both new building construction and existing building revamping

More information as of Page 48.

More information as of Page 82.

» NEW: up to a 2.400 mm diameter

» NEU: up to a 25.000 litre vessel capacity

» Up to a max. 16 bar operating pressure (conditional upon capacity)

» Storage tank: 0°C - 95°C / heat exchanger: 0°C - 160°C (25 bar)

» High-grade S235JR+N quality steel

» NEW: Enamel storage tank up to 5.000 litres and Ø 1.500 mm

» Various heat and low-temperature insulations

» TÜV-tested on request

New

at t

he a

ssor

tmen

t

Convincing advantages

Convincing advantages

» Buffer storage tank » Cold water storage tank (KWP)

» Domestic water storage tank » and many more...

Stay up to date! The first place to view all information on our innovations is on our website www.huch.com.

NEWNEW

NEW

Page 8: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

8 I www.huch.com

High-grade bare-tube heat exchangerThanks to a special heat exchanger design and arrangement a high extraction grade of up to 96% is attained.

Flexible sensor positioningSensor clamping strips allow the temperature sensor to be positioned at will. As a result, the Huch storage tanks are suitable for many application fields. (barring storage tanks with PU rigid foam; here firmly positi-oned sensor/controller connections).

Innovative storage tank insulationPolyline® fleece insulation - High-grade fleece insulation incl. 100 mm cap and 50 mm base insulation; this reduces the heat loss by 10-15 %.

PU rigid foam insulation - Vessels are firmly foamed with high-grade polyurethane foam No chimney effect arises. The insulation is 50 mm thick and has excellent insulating properties.

Our quality features

Connection stubsOur connection stubs are a standard 50 mm in length. The fleece insulation thus insulates any non-used connections. This cuts radiation losses and an improved energy efficiency is achieved by the storage tank.All enamelled storage tank types have flat-sealing male threads. This stops the enamel peeling off at the installation stage.

Manifold connection scopeOur combined and buffer storage tanks have a host of connections. This makes possible an optimum system attachment for the most varied of applications.

Optimum temperature stratificationStratification guiding channels and baffle plates ensure that temperature swirls in the storage tank are reduced.

Use of the entire storage tank capacityAn optimum hot water connection at the top of the storage tank means that the storage tank capacity is fully utilised.

Quality featuresGood reasons for Huch quality products

1

2

3

4

5

6

1 2 3

4 5 6

Page 9: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 9

Cert

ifica

tes

/ Qua

lifica

tions

/ W

arra

nty

* A warranty claim can only be made on condition that all stipulations of the sales and delivery terms of Huch GmbH Behälterbau are met. Substantiation is on hand that commissioning and installation was carried out by a specialist tradesman or an authorized specialist company in keeping with the installation and maintenance information attached to the storage tank or vessel. It is assumed that the components were fitted correctly. It can be proved across the entire service life of the vessel and anode that they were regularly serviced. (completely filled-in pass card, proof on hand from invoice copies of the maintenance work). ** possible for an extra charge / special arrangement

Certificates / Qualifications / Warranty

Our warranty pledge Huch GmbH Behälterbau grants the following on:

We are certificated and qualified on the basis of:

Standard storage tank range: A 5-year warranty*

Stainless steel storage tank and Stainless steel currugarted tube: A 2-year warranty*

Galvanised tanks: A 2-year warranty*

Polyline© fleece insulation: A 2-year warranty*

Domestic water-, solar-, buffer- and combined storage tank: A 10-year warranty (optional)**

TÜV certificate:

» Quality management system as per Iso 9001:2015

» Manufacturer and welding undertaking in keeping with AD 2000 HP 0 / DIN EN ISO 3834

» RL 2014/68/EU Pressure equipment (CE 0035)

» RL 2014/29/EU Non-complex pressure equipment, EN 286 Parts 1 + 3

DNV GL tanks according to GL rules

Page 10: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

10 I www.huch.com

General installation instructions

These general installation instructions do not replace the assembly and installation instructions attached to the storage tank. They contain additional instructions pertaining to the appliance!

Requirements placed on where installation takes place» Only install storage tank where there is no risk of frost» Firm, level base that can absorb loads» Short piping lengths to the user

Transfer to where the installation takes place» Clear the path to the installation site of any obstacles and items that could cause you to trip» Note the dimensions of the storage tank

Gap to the walls and solid fuel boilers» Keep to the minimum spacing as specified in the installation and assembly instruction attached to the storage tank» In keeping with the fire system ordinance, a minimum spacing of 1.000 mm is to be kept to the boiler (sparks could fly)

Commissioning» An authorized specialist firm is to undertake assembly, installation and commissioning» Seal tightness is to be checked at the commissioning stage » Before filling the system, check and, if necessary, re-tighten the tightening torques of the flange connection. This is also to be done after each start-up and after the initial heat-up» Tightening torque of the flanges: 20 - 30 Nm» Seals represent wear parts and are only to be used once» Flat-sealing R-threaded joints must not be used for any other purposes (R-thread with thread sealant, e.g. hemp or sealing tape, are not permitted)» Cold water access line to be fitted with an appropriate water filter» Handle heating water in line with VDI 2035n» The specified operating temperatures and pressure must not be exceeded

The installation of heating and domestic water storage tanks is subject to DIN, DVGW and VDI regulations and recommendations. They include the instruction on avoiding mixed installations and corrosion damage.

Note the following when undertaking installation:

Maintenance instructionsParticular attention is to be given to the following rules and recommendations:» Internal inspection / cleaning is recommended 1x a year» Sealstobereplacedduringmaintenanceormodificationwork,butafter2yearsattheverylatest» Only use genuine parts when undertaking maintenance

Page 11: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 11

Gen

eral

inst

alla

tion

inst

ruct

ions

Domestic water must not react corrosively on enamel or stainless steel

Domestic water is to be within the TWVO determining limits (electrical conductivity ≥ 200 μS/cm)

Domestic water PH figure: <8 / ideally 6.5 - 7

Water hardness: min. 7° dH

Stainless steel: A chloride content above 120 mg/l at temperatures of ≥ 60°C is considered to the critical

galvanized tanks and boilers: up to a max. 50°C

Our enamelled domestic water storage tanks comply with the strict domestic water ordinance as per §17 of the German Environmental Office and are deemed hygienically unproblematic. The same holds good for all those deployed components in contact with domestic water during operations. The smooth enamel surface reduces limescale and coating formation down to a minimum.

Installation - Domestic water storage tankWater is a precious item that keeps us alive

Water properties:

Domestic water conformity - pro-duction in acc. with UBA guidelinesWhat counts is the quality of the materials used

Domestic water storage tanks at the installation stage are subject to specific, tighter specifications. This is to rule out contamination of whatever kind. Acting as a form of corrosion protection enamelling has a vital role to pay given that water is a corrosive medium. Our domestic water storage tanks are designed in an enamel-compliant manner. This means there are no sharp edges inside the vessel where the enamel does not adhere properly, the enamel layer is uneven or major imperfections could develop. Even so, it is not possible to produce a 100% fault-free enamel surface. That is why magnesium or impressed-current anodes are additionally used to protect the minimum flaws.

Note the following when installing a domestic water storage tank:

» Installation in acc. with DIN and DVGW specifications (including DIN EN 806, DIN 1988, DIN 4753, DIN EN 1717)» Pay attention to the regulations of the local water supplier

» Avoid any pressure blows in the domestic water mains grid e.g. from an expansion tank or delay-closing valves etc.

Page 12: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

12 I www.huch.com

Dimensioning of buffer storage tanks

Buffer storage tanks are used in the most varied of heating systems. They store hot water from when heated until its extraction when required and, in this way, bridge operating interruptions of the heat generators. Only correct dimensioning saves you from unnecessary energy consumption and costs.

As-needed design calculation acc. to heat generator:

Note: If it is a matter of the size of the buffer storage tank (tank capacity), then preference should preferably be given to the larger appropriate model. It must be appreciated here that the capacity of the buffer storage tanks increases four-squared to the diameter. This means that a larger buffer storage tank will always be higher than thicker. Please refer on this to our size chart as from Page 84.

Hot water storage tank dimensioningEstablishing what is needed for efficient operation of the heating system

Buffer storage tanks are selected and designed in line with the following parameters:

» Type of heat generation, e.g. CHP, solid fuels, solar

» Receiving system types, e.g. under-floor heating, domestic water, radiators

» Loading and unloading capacities

» Individual heat demand

» Properties of the heat transferring fluid

» Hydraulic components and aspects (pressure ratios)

» Characteristics of the heat-transferring components

» Utilization degree

» Effective heat flow volume in kWh

» Additional heating system

VPS = 15 * QK * TB * (1 - 0,3 * QH / QKmin )

VPS = Capacity of the buffer storage tank in l

QK = Boiler rated output in kW

TB = min. boiler output in kW

QH = Nominal burn-off period in h

QKmin = Heating load of the building in kW

VPS = Capacity of the buffer storage tank in l

PWP = Heat output of the heat pump in kW

t = Bridging time given an interruption to operations

c = Specific water heat capacity

∆T = Temperature difference Supply flow / Return flow in K

VPS = Capacity of the buffer storage tank in l

AWF = Living space to be heated in m3

VSP = Specific storage tank flow per m2 of collector surface in l/m2

aWF = Specific living space per m2 of collector surface in l/m2

Solid fuels - in keeping with DIN EN 303-5:

Heating pumps:

Solar installations:

VPS = AWF * VSP

aWF

VPS = PWP * t

(c * ∆T)

Page 13: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 13

Dimensioning of domestic water storage tanks

The size of the domestic water storage tank should be optimally dimensioned and designed to cater for needs to ensure that the heating system is run in an energy and cost-efficient manner. The number of people in the household and their hot water consumption determine the hot water requirements. The 6023 VDI directive proceeds on the assumption of a daily per head consumption of 30-50 litres of domestic hot water. This is in addition to a minimum 100 litres capacity which planning should also consider.

Dim

ensi

onin

g of

sto

rage

tank

s

» Number of those in the household

» Number of dwelling units (detached house or apartment block)

» Type of heat generation

» Boiler output

» Loading and unloading capacities

» Individual hot water demand

» Hydraulic components and aspects (pressure ratios)

Hot water demand - centrally supplied apartmentsDetermining the requirement figure N to establish the size of the hot water storage heater

1 2 3 4 5 6 7 8 9 10

Apar

tmen

t gro

ups

num

ber o

f roo

ms

num

ber o

f ap

artm

ents

num

ber o

f oc

cupa

nts

per f

lat

tapp

ing

poin

t nu

mb

brie

f des

crip

tion

(see

bel

ow)

tapp

ing

poin

t re

quire

men

t in

Wh

tapp

ing

poin

t num

ber

x ta

ppin

g po

int

requ

irem

ent i

n W

h

Wh

r n p n*p z wV z*wV n*p*ΣwV

1 4 1 3,5 3,5 1 NB1 5.820 5.820 20.370

Domestic water storage tanks are designed in line with the following parameters:

As-needed design calculation in keeping with form DIN 4708-2 (example here of a detached house with bath-equipped bathroom):

Note: This is an extract from DIN 4708-2. The extensive design calculation of domestic water storage tanks is subject to additional calculations. They can be taken from the DIN.

Σ(n*p*ΣwV) = 20.370 Wh N = 1

Procedure - Enter particulars in the following columns of the form:1] Consecutive number of the same apartments in acc. with number of rooms and extent of the sanitary equipment2] Number of rooms according to the structural drawings3] Number of apartments and/or residential units4] No. of occupants per flat acc. the owner5] Outcome of the multiplication Column 3 with Column 46] Number of tapping points to be considered (e.g. bath, washstand, sink)7] Brief description of the tapping points entered in Column 68] Tapping point requirement based on particulars from9] Outcome of the multiplication Column 6 with Column 810] Outcome of the multiplication Column 5 with Column 9Enter the outcome in the equation of the supply pressure and calculate the N requirement figure.

Calculate the storage tank on the basis of the N requirement figure and the NL capacity figure, NL ≥ N applies here!

tapping point briefdescription WV in Wh VE in L

Bath NB1 5820 140

Bath NB2 6510 160

Small bathroom-sized bath KB 4890 120

Bath for a large-area bathroom GB 8720 200

Shower set with mixer tap BRS 1630 40

Standard shower set BRN 3660 90

Luxury shower set RRL 7320 180

Washstand WT 700 17

Bidet BD 810 20

Wash basin HAT 350 9

Sink SP 1160 30

Σ(n*p*ΣwV) 20.370 Wh

3,5 * 5.820 20.370 WhN = = = 1

Page 14: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

14 I Solar storage tanks

© iStock / Ilya Bushuev

Huch solar storage tankHot water convenience even when the sun doesn't shine.Our solar storage tanks are especially oriented to solar thermal installations. They have at least two large bare-tube heat exchangers and ensure that heat is rapidly transferred. The solar storage tanks can be easily combined with other heat generators, such as condenser boilers or a pellet heating system. Become part of the future and use regenerative energies. This goes easy on both the environment and your wallet/purse.

Page 15: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 15

Quality features

Connection scheme

High-grade bare-tube heat exchangersThanks to a special heat exchanger design and arrangement a high extraction grade of up to 96% is achieved.

Domestic water-suitedHygienically correct domestic water heating thanks to high-grade enamelling. An anode supplied as standard also provides protection from corrosion.

Connection stubsOur connection stubs are a standard 50 mm in length. The fleece insulation thus insulates any non-used connections. This cuts radiation losses and an improved energy efficiency is achieved by the storage tank.

Use of the entire storage tank capacityAn optimum hot water connection at the top of the storage tank means that the storage tank capacity is fully utilised.

Flexible positioning of the temperature sensorsSensor clamping strips allow the temperature sensor to be positioned at will. As a result, the Huch storage tanks are suitable for many application fields. (barring storage tanks with PU rigid foam; here firmly positioned sensor/controller connections).

Innovative highly efficient storage tank insulationThe high-grade Polyline© fleece insulation incl. a 100 mm lid and a 50 mm base insulation reduces heat loss by 10-15 % over soft foam.

PU rigid foam insulation - 50 mm high-grade polyurethane foam firmly wraps up the vessels in foam. No chimney effect develops and the insulation has excellent insulating properties.

1

2

3

4

5

5

6

The SSH solar storage tank is shown in the illustration.

1

4

3

6

2

Schematic diagram – relevant standards and regulations must be observed!

Cold water

Wall-hung heater

Sola

r sto

rage

tank

s

Page 16: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

16 I Solar storage tanks

» Material: S235JR+N steel, internal enamelled, external primer coat » Compressive strenght: 10 bar» Technical features: two large bare-tube heat exchanger, Magnesium protection anode 1¼“, Sensor sleeve, Thermometer, Inspection flange 180 x 110 x LK 150» Connections: Standard 1½“ sleeve for retrofitting an electric heating, flat-sealing external threads» Insulation: 50 mm PU rigid foam insulation with Sky-coating» SVGW certified: ESS-PU 200 - 500 l (No. 1103-5831)» Levelling feet see list of accessories» the storage tanks ESS-PU 200 and 300 l are suited for our heating pump VARIO S» Energy efficiency class "B" until 500 Litres on request» Accessories: are on the pages 90 to 97

Note: Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water. See Pages 10/11, Installation instructions!

Suitable for1:

Storage type ESS-PU 200 300 400 500

Price

Storage tank with insulation [€/item] 1037,- 1199,- 1466,- 1663,-

Order number

Storage tank with insulation RAL 9006 16593 14598 13813 14971

Product description

Price / order number

Solar storage tank ESS-PU

Pellet heating

Condensing power plant

Oil heating plant

Gas plant

Solar heating plant

Direct heating system

Circulation (Z)

Return flow (RL1)

Sensor/controller connections

Sensor/controller connectionsInlet flow (VL2)

Hot water (WW)

Inlet flow (VL1)

Return flow (RL2)

Cold water (KW)

Inspection flange with optional connection for additional heat sources (RFL)

Levelling feet (optional)

M8 thermometer option

Electric heating

Suited for VARIO S

SVGW certified

1) Special solutions such as the combination of various heat sources also allow for other applications.

Drinking water

Heater

Page 17: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 17

Technical data

Storage type ESS-PU 200 300 400 500

Contents [Litres] 200 300 400 500

Energy efficiency class

Heat retaining loss (with insulation) [Watt] 84 90 95 99

Diameter without insulation [mm] 500* 500* 600* 650*

Diameter with insulation [mm] 600 600 700 750

Insulation [mm] 50* 50* 50* 50*

Height with insulation [mm] 1232 1697 1660 1783

Tilted height [mm] 1370 1800 1800 1970

Heating surface top/bottom [m2] 0,6 / 0,8 0,8 / 1,2 1,0 / 1,5 1,2 / 1,8

Water content WT top/bottom [Litres] 3,8 / 5,0 5,0 / 7,5 6,3 / 9,4 7,5 / 11,3

Flow rate WT top/bottom [m3/h] 0,7 / 1,2 1,0 / 1,6 1,2 / 2,0 1,4 / 2,4

Pressure WT top/bottom [mbar] 30 / 70 35 / 90 45 / 120 55 / 250

NL number** top/bottom according to DIN 4708

1,23 / 3,6 1,8 / 8 2,1 / 11 2,5 / 14

Continuous output top/bottom according to DIN 4708 (10°/80°/45°)

[l/h] (kW) 410 (16,7) / 710 (28,9)

605 (24,6) / 970 (39,5)

720 (29,3) / 1180 (48,0)

830 (33,8) / 1400 (57,0)

max. T/ max. P - TW [°C/bar] 95 / 10 95 / 10 95 / 10 95 / 10

max. T/ max. P - GWT-HZG*** [°C/bar] 160 / 25 160 / 25 160 / 25 160 / 25

Cold water / hot water AG (KW/WW) [Inch] G 1 G 1 G 1 G 1

Circulation AG (Z) [Inch] G ¾ G ¾ G ¾ G ¾

Heat exchanger all AG (VL/RL) [Inch] G ¾ G ¾ G ¾ G ¾

Electric heating IG (E-HZG) [Inch] G 1 ½ G 1 ½ G 1 ½ G 1 ½

Nominal width of control flange (RFL) DN 110 DN 110 DN 110 DN 110

Sensor/controller connections (F1, F2) Sensor sleeve, internal diameter = 9 mm

Thermometer connections M8 thermometer option

Dimensions ESS-PU 200 300 400 500

KW [mm] 110 110 127 128

RL 1 [mm] 180 180 205 205

VL 1 [mm] 630 580 635 685

RL 2 [mm] 780 945 965 1020

Z [mm] 880 1045 1065 1125

VL 2 [mm] 990 1215 1261 1325

WW [mm] top top top top

E-HZG [mm] 705 770 770 920

Weight [kg] 85 114 166 215

* Insulation not removable ** In order to achieve the specified NL number, the boiler output must be higher than the specified continuous output. *** Operating media for heat exchanger: water in liquid state only.

Sola

r sto

rage

tank

s

Page 18: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

18 I Solar storage tanks

Solar storage tank SSH

Product description

Price / order number

Storage type SSH 301 301 401 501 751 1001 1500 2000

Price Ø=600 Ø=550

Storage tank without insulation [€/item] - - - - 2958,- 3423,- 5021,- 5892,-

Storage tank with insulation [€/item] 1615,- 1605,- 1869,- 2092,- - - - -

Fleece insulation [€/item] - - - - 638,- 828,- 1058,- 1184,-

Order number

Storage tank without insulation - - - - 17230 17236 23756 23553

Storage tank with insulation RAL 9006 (only to 500 l)

36641 36642 36643 36644 - - - -

Fleece insulation RAL 9006 - - - - 28439 28440 28441 28442

» Material: S235JR+N steel, internal enamelled, external primer coat» Compressive strenght: 10 bar» Technical features: two large bare-tube heat exchanger, Magnesium protection anode 1¼“ (from 750 Litres is a impressed current anode a standard), Sensor clamping strip, Inspection flange 180 x 110 x LK 150 (over 750 Litres 280 x 200 x LK245), up to 1001 Litres is the thermometer enclosed in the scope of delivery» Connections: Standard 1½“ sleeve for retrofitting an electric heating, flat-sealing external threads» Insulation: 100 mm polyline fleece insulation including base and lid insulation» on request up to 5.000 liters possible» Energy efficiency class "B" until 500 Litres on request» Accessories: are on the pages 90 to 97

Note: Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water. See Pages 10/11, Installation instructions!

Hot water (WW)

Return flow (RL1)

Inlet flow(VL2)

Magnesium anode

Inlet flow (VL1)

Return flow (RL2)

Circulation (Z)

Cold water (KW)

Inspection flange with optional connection for additional heat sources (RFL)

Foot ring

Electric heating

M8 thermometer option

Suitable for1:

1) Special solutions such as the combination of various heat sources also allow for other applications.

Pellet heating

Condensing power plant

Oil heating plant

Gas plant

Solar heating plant

Direct heating system

Drinking water

Heater

Page 19: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 19

Technical data

Storage type SSH 301 301 401 501 751 1001 1500 2000 Ø=600 Ø=550

Contents [Litres] 300 300 400 500 750 1000 1500 2000

Energy efficiency class

Heat retaining loss (with insulation)

[Watt] 92 92 102 112 131 146 168 186

Diameter without insulation [mm] 600 550 600 650 750 850 1000 1100

Diameter with insulation [mm] 800 750 800 850 950 1050 1200 1300

Insulation [mm] 100 100 100 100 100 100 100 100

Height with insulation [mm] 1353 1645 1725 1835 2082 2015 2250 2410

Tilted height [mm] 1320 1620 1690 1800 2050 2030 2260 2440

Heating surface top/bottom [m2] 1,0 / 1,3 1,0 / 1,4 1,2 / 1,7 1,5 / 2,1 1,9 / 2,7 1,9 / 2,9 2,0 / 4,0 2,0 / 4,0

Water content WT top/bottom [Litres] 6,3 / 8,2 6,3 / 8,8 7,6 / 10,7 9,4 / 13,2 16,0 / 22,8 16,0 / 24,5 17,0 /34,0 17,0 /34,0

Flow rate WT top/bottom [m³/h] 1,1 / 1,7 1,1 / 1,9 1,4 / 2,1 1,5 / 2,8 2,1 / 4,2 2,1 / 4,6 2,2 / 5,1 2,2 / 5,1

Pressure WT top/bottom [mbar] 40 / 60 40 / 80 50 / 130 60 / 280 40 / 180 40 / 200 42 / 265 42 / 265

NL number top/bottom** according to DIN 4708

2 / 9 2 / 11 2,2 / 13 2,8 / 18 13 / 35 13 / 41 17 / 46 21 / 55

Continuous output top/bot-tom according to DIN 4708 (10°/80°/45°)

[l/h](kW)

660 (26,9) / 1005 (41,0)

660 (26,9) / 1130 (46,0)

790 (32,2) / 1270 (51,7)

905 (36,8) / 1620 (65,9)

1220 (49,7) / 2470 (100,5)

1220 (49,7) / 2690 (109,5)

1280 (52,1) /2990 (121,7)

1280 (52,1) /2990 (121,7)

max. T/ max. P - TW [°C/bar] 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10

max. T/ max. P - GWT-HZG*** [°C/bar] 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25

Cold water / hot water AG (KW/WW)

[Inch] G 1 G 1 G 1 G 1 G 1½ G 1½ G 2 G 2

Circulation AG (Z) [Inch] G¾ G¾ G¾ G¾ G¾ G¾ G 1 G 1

Heat exchanger all AG (VL/RL)

[Inch] G 1 G 1 G 1 G 1 G 1¼ G 1¼ G 1½ G 1½

Electric heating IG (E-HZG) [Inch] G 1 1/2 G 1 1/2 G 1 1/2 G 1 1/2 G 1 1/2 G 1 1/2 G 1½ G 1½

Nominal width of control flange (RFL) DN 110 DN 110 DN 110 DN 110 DN 200 DN 200 DN 200 DN 200

Sensor/controller connections Sensor clamping strip

Thermometer connections M8 thermometer option No No

Dimensions

KW [mm] 120 110 120 130 157 190 230 255

RL 1 [mm] 220 205 220 225 280 350 375 400

VL 1 [mm] 570 675 690 875 967 920 1125 1150

RL 2 [mm] 773 950 1015 1020 1127 1140 1275 1300

Z [mm] 873 1050 1115 1120 1227 1240 1425 1450

VL 2 [mm] 1033 1290 1355 1490 1567 1525 1650 1675

WW [mm] 1156 1460 1528 1630 1855 1800 1860 2005

E-HZG [mm] 673 850 915 920 1032 1016 1200 1225

Weight [kg] 164 156 178 234 344* 400* 495* 590*

* Weight without Insulation** In order to achieve the specified NL number, the boiler output must be higher than the specified continuous output.*** Operating media for heat exchanger: water in liquid state only.

Sola

r sto

rage

tank

s

Page 20: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

20 I Solar storage tanks

Solar storage tank SSH-Plus

Product description

Price / order number

Hot water (WW)

Return flow (RL1)

Internal Inlet flow (VL i)

External Inlet flow (VL a)

Magnesium anode

Internal Return flow (RL i)

Inlet flow (VL1)

External Return flow (RL a)

Circulation (Z)

Cold water (KW)

Inspection flange with optional connection for additional heat sources (RFL)

Foot ring

Electric heating

Storage type SSH-Plus 351 501 801

Price

Storage tank without insulation [€/item] - - 3508,-

Storage tank with insulation [€/item] 2065,- 2550,- -

Fleece insulation [€/item] - - 618,-

Order number

Storage tank without insulation - - 25310

Storage tank with insulation RAL 9006 38095 28422 -

Fleece insulation RAL 9006 - - 28426

» Material: S235JR+N steel, internal enamelled, external primer coat» Compressive strenght: 10 bar» Technical features: overhead double bare-tube heat exchanger (equal tube length inside / outside, operating modes of heat exchanger pair: parallel mode / single mode / series mode), solar heat exchanger positioned at the bottom, Magnesium protection anode 1¼“ (from 800 Litres impressed current anode), Sensor clamping strip, Inspection flange 180 x 110 x LK 150» Connections: Standard 1½“ sleeve for retrofitting an electric heating, flat-sealing external threads» Insulation: 100 mm polyline fleece insulation including base and lid insulation» Energy efficiency class "B" until 500 Litres on request» Accessories: are on the pages 90 to 97

Note: Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water. See Pages 10/11, Installation instructions!

Suitable for1:

Pellet heating

Condensing power plant

Oil heating plant

Gas plant

Solar heating plant

Direct heating system

Drinking water

Heater

1) Special solutions such as the combination of various heat sources also allow for other applications.

Heating pump system

Page 21: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 21

Technical data

Storage type SSH-Plus 351 501 801

Contents [Litres] 350 500 800

Energy efficiency class

Heat retaining loss (with insulation) [Watt] 98 112 135

Diameter without insulation [mm] 600 650 800

Diameter with insulation [mm] 800 850 1000

Insulation [mm] 100 100 100

Height with insulation [mm] 1678 1909 1970

Tilted height [mm] 1620 1860 1950

Heating surface top/bottom [m²] 3,3(2x1,65) / 1,3 4,95(2x2,43) / 1,8 6,0(2x3,0) / 2,0

Water content WT top/bottom [Litres] 21 / 8,2 31 / 11 38 / 13

Flow rate WT top/bottom [m³/h] 3,6 / 1,7 4,0 / 2,1 4,0 / 2,7

Pressure loss WT oben Series/Parallel/Single mode

[mbar] 410 / 60 / 200 750 / 110 / 350 830 / 120 / 420

Pressure loss WT unten [mbar] 60 130 170

NL number* according to DIN 4708 top(parallel)/bottom

18 / 9 35 / 13 35 / 20

Continuous output top/bottom according to DIN 4708 (10°/80°/45°)

[l/h](kW)

2100 (85,5) / 1000 (40,7)

2500 (101,8) / 1270 (51,7)

2500 (101,8) / 1650 (67,2)

max. T/ max. P - TW [°C/bar] 95 / 10 95 / 10 95 / 10

max. T/ max. P - GWT-HZG*** [°C/bar] 160 / 25 160 / 25 160 / 25

Cold water / hot water AG (KW/WW) [Inch] G 1 G 1 G 1 ½

Circulation AG (Z) [Inch] G¾ G¾ G¾

Heat exchanger all AG (VL/RL) [Inch] G 1 G 1 G 1

Electric heating IG (E-HZG) [Inch] G 1 ½ G 1 ½ über RFL

Nominal width of control flange (RFL) DN 110 DN 110 DN 110

Sensor/controller connections Sensor clamping strip

Thermometer connections No No No

Dimensions

KW [mm] 120 130 160

RL1 [mm] 218 217 245

VL1 [mm] 568 637 645

RL (i) [mm] 668 737 745

RL (a) [mm] 751 820 845

Z [mm] 1063 1218 1045

VL (a) [mm] 1123 1430 1415

VL (i) [mm] 1323 1567 1535

WW [mm] 1461 1704 1740

E-HZG [mm] 618 687 -

Weight [kg] 172 255 400

* In order to achieve the specified NL number, the boiler output must be higher than the specified continuous output.** Operating media for heat exchanger: water in liquid state only.

Sola

r sto

rage

tank

s

Page 22: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

22 I Domestic water storage tanks

© panthermedia.net /kurhan

Huch domestic water storage tankWater - the elixir of lifeOur domestic water storage tanks find their place in a hygienically trouble-free preparation of domestic water owing to quality-tested enamelling. We guarantee maximum quality on the basis of German standards and technical norms. The domestic water storage tanks can be combined with various heat generators.

Page 23: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 23

1

2

3

4

5

The HLS-Plus domestic water storage tank is shown in the illustration.

1

4

3

6

2

Quality features

Connection scheme

Schematic diagram – relevant standards and regulations must be observed!

Cold water

Heating pump

High-grade bare-tube heat exchangersThanks to a special heat exchanger design and arrangement a high extraction grade of up to 96% is achieved.

Domestic water-suitedHygienically correct domestic water heating thanks to high-grade enamelling. An anode supplied as standard also provides protection from corrosion.

Connection stubsOur connection stubs are a standard 50 mm in length. The fleece insulation thus insulates any non-used connections. This cuts radiation losses and an improved energy efficiency is achieved by the storage tank.

Use of the entire storage tank capacityAn optimum hot water connection at the top of the storage tank means that the storage tank capacity is fully utilised.

Flexible positioning of the temperature sensorsSensor clamping strips allow the temperature sensor to be positioned at will. As a result, the Huch storage tanks are suitable for many application fields. (barring storage tanks with PU rigid foam; here firmly positioned sensor/controller connections).

Innovative highly efficient storage tank insulationThe high-grade Polyline© fleece insulation incl. a 100 mm lid and a 50 mm base insulation reduces heat loss by 10-15 % over soft foam.

PU rigid foam insulation - 50 mm high-grade polyurethane foam firmly wraps up the vessels in foam. No chimney effect develops and the insulation has excellent insulating properties.

5

6

Dom

estic

wat

er s

tora

ge ta

nks

Page 24: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

24 I Domestic water storage tanks

Domestic water storage tank EBS-PU

Price / order number

Storage type EBS-PU 120 150 200 300 400 500

Price

Storage tank with insulation [€/item] 782,- 838,- 913,- 1108,- 1339,- 1557,-

Order number

Storage tank with insulation RAL 9006 14300 15280 14597 14596 15186 14599

Hot water (WW)

Sensor/controller connections (F1)

Inlet flow (VL)

Return flow (RL)

Circulation (Z)

Cold water (KW)

Inspection flange with optional connection for additional heat sources (RFL)

Levelling feet (optional)

Electric heating

M8 thermometer option

Product description» Material: S235JR+N steel, internal enamelled, external primer coat » Compressive strenght: 10 bar» Technical features: large bare-tube heat exchanger, Magnesium protection anode 1¼“, Sensor sleeve, Thermometer, Inspection flange 180 x 110 x LK 150» Connections: Standard 1½“ sleeve for retrofitting an electric heating, flat-sealing external threads» Insulation: 50 mm PU rigid foam insulation with Sky-coating» SVGW certified: EBS-PU 120 - 500 l (No. 1103-5831)» Levelling feet see list of accessories» the storage tanks EBS-PU 200 and 300 l are suited for our heating pump VARIO S» Energy efficiency class "B" until 500 Litres on request» Accessories: are on the pages 90 to 97

Note: Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water. See Pages 10/11, Installation instructions!

Suited for VARIO S

SVGW certified

Suitable for1:

Pellet heating

Condensing power plant

Oil heating plant

Gas plant

Direct heating system

Drinking water

Heater

1) Special solutions such as the combination of various heat sources also allow for other applications.

Page 25: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 25

Storage type EBS-PU 120 150 200 300 400 500

Contents [Litres] 120 150 200 300 400 500

Energy efficiency class

Heat retaining loss (with insulation) [Watt] 69 73 84 90 95 99

Diameter without insulation [mm] 500* 500* 500* 500* 600* 650*

Diameter with insulation [mm] 600 600 600 600 700 750

Insulation [mm] 50* 50* 50* 50* 50* 50*

Height with insulation [mm] 814 969 1232 1697 1660 1783

Tilted height [mm] 1011 1140 1370 1800 1750 1970

Heating surface [m²] 0,6 0,7 0,9 1,2 1,5 1,8

Water Content WT [Litres] 3,8 4,4 5,7 7,5 9,4 11,3

Flow rate WT [m³/h] 0,8 1,0 1,2 1,6 2,0 2,4

Pressure loss WT [mbar] 30 50 70 60 120 250

NL number** according to DIN 4708 1,7 2,1 3,6 8 11 14

Continuous output according to DIN 4708 (10°/80°/45°)

[l/h](kW)

460 (18,7) 580 (23,6) 710 (28,9) 970 (39,5) 1180 (48,0) 1400 (57,0)

max. T/ max. P - TW [°C/bar] 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10

max. T/ max. P - GWT-HZG*** [°C/bar] 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25

Cold water / hot water AG (KW/WW) [Inch] G 1 G 1 G 1 G 1 G 1 G 1

Circulation AG (Z) [Inch] G ¾ G ¾ G ¾ G ¾ G ¾ G ¾

Heat exchanger AG (VL/RL) [Inch] G ¾ G ¾ G ¾ G ¾ G ¾ G ¾

Electric heating IG (E-HZG) [Inch] G 1 ½ G 1 ½ G 1 ½ G 1 ½ G 1 ½ G 1 ½

Nominal width of control flange (RFL) DN 110 DN 110 DN 110 DN 110 DN 110 DN 110

Sensor/controller connections (F1) Sensor sleeve, internal diameter = 9 mm

Thermometer connections M8 thermometer option

Dimensions

KW [mm] 110 110 110 110 127 128

RL [mm] 180 180 180 180 205 205

VL [mm] 450 520 630 580 635 685

Z [mm] 520 660 780 1045 1065 1125

WW [mm] top top top top top top

E-HZG [mm] 520 600 800 770 770 920

Weight [kg] 59 66 73 94 151 195

* Insulation not removable ** In order to achieve the specified NL number, the boiler out*** Operating media for heat exchanger: water in liquid state only

Technical data

Dom

estic

wat

er s

tora

ge ta

nks

Page 26: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

26 I Domestic water storage tanks

Domestic water storage tank BS

Price / order number

Hot water (WW)

Return flow (RL)

Magnesium anode

Inlet flow (VL)

Circulation (Z)

Cold water (KW)

Inspection flange with optional connection for additional heat sources (RFL)

Foot ring

Electric heating

M8 thermometer option

Storage type BS 122 152 202 301 401 501 751 1001 1500 2000

Price

Storage tank without insulation [€/item] - - - - - - 2637,- 3090,- 4671,- 5470,-

Storage tank with insulation [€/item] 1044,- 1096,- 1216,- 1442,- 1689,- 1886,- - - - -

Fleece insulation [€/item] - - - - - - 638,- 828,- 1058,- 1184,-

Order number

Storage tank without insulation - - - - - - 17227 17233 24464 24471

Storage tank with insulation RAL 9006 (only to 500 l)

36659 36634 36635 36637 36638 36639 - - - -

Fleece insulation RAL 9006 - - - - - - 28439 28440 28441 28442

Product description» Material: S235JR+N steel, internal enamelled, external primer coat » Compressive strenght: 10 bar» Technical features: large bare-tube heat exchanger, Magnesium protection anode 1¼“ (from 750 Litres impressed current anode), Sensor clamping strips, Inspection flange 180 x 110 x LK 150 (ab 750 Litres 280 x 200 x LK245), up to 1001 Litres is the thermometer enclosed in the scope of delivery Note: for BS 1500 & 2000 Litres the insertion of an electric heating only possible via the E-HZG sleeve, do not overlie the flange!» Connections: Standard 1½“ sleeve for retrofitting an electric heating, flat-sealing external threads» Insulation: 100 mm polyline fleece insulation including base and lid insulation» on request up to 5.000 liters possible» Energy efficiency class "B" until 500 Litres on request» Accessories: are on the pages 90 to 97

Note: Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water. See Pages 10/11, Installation instructions!

Suitable for1:

Pellet heating

Condensing power plant

Oil heating plant

Gas plant

Direct heating system

Drinking water

Heater

1) Special solutions such as the combination of various heat sources also allow for other applications.

Page 27: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 27

Technical data

Storage type BS 122 152 202 301 401 501 751 1001 1500 2000

Contents [Litres] 120 150 200 300 400 500 750 1000 1500 2000

Energy efficiency class

Heat retaining loss (with insulation)

[Watt] 65 74 83 92 102 112 131 145 168 186

Diameter without Insulation [mm] 500 500 500 550 600 650 750 850 1000 1100

Diameter with insulation [mm] 700 700 700 750 800 850 950 1050 1200 1300

Insulation [mm] 100 100 100 100 100 100 100 100 100 100

Height with insulation [mm] 864 1022 1282 1645 1725 1835 2082 2015 2250 2410

Tilted height [mm] 850 1000 1250 1620 1690 1800 2050 2030 2260 2440

Heating surface [m²] 0,7 1,0 1,4 1,4 1,7 2,1 2,7 2,9 4,0 4,0

Water Contents WT [Litres] 4,5 6,3 8,8 8,8 10,7 13,2 22,8 24,5 34,0 34,0

Flow rate WT [m³/h] 1,0 1,3 1,6 1,9 2,1 2,7 4,2 4,6 5,1 5,1

Pressure loss WT [mbar] 30 50 70 80 130 280 180 200 265 265

NL number** according to DIN 4708 1,9 2,5 4,8 11 13 18 35 41 46 55

Continuous output according toDIN 4708 (10°/80°/45°)

[l/h](kW)

580 (23,6)

750 (30,5)

940 (38,3)

1130 (46,0)

1270 (51,7)

1620 (65,9)

2470(100,5)

2690 (109,5)

2990 (121,7)

2990 (121,7)

max. T/ max. P - TW [°C/bar] 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10

max. T/ max. P - GWT-HZG*** [°C/bar] 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25

Cold water / hot water AG (KW/WW) [Inch] G 1 G 1 G 1 G 1 G 1 G 1 G 1½ G 1 ½ G 2 G 2

Circulation AG (Z) [Inch] G ¾ G ¾ G ¾ G ¾ G ¾ G ¾ G ¾ G ¾ G 1 G 1

Heat exchanger AG (VL/RL) [Inch] G 1 G 1 G 1 G 1 G 1 G 1 G 1¼ G 1¼ G 1½ G 1½

Electric heating IG (E-HZG) [Inch] G 1½ G 1½ G 1½ G 1½ G 1½ G 1½ G 1½ G 1½ G 1½ G 1½

Nominal width of control flange (RFL) DN 110 DN 110 DN 110 DN 110 DN 110 DN 110 DN 200 DN 200 DN 200 DN 200

Sensor/controller connections Sensor clamping strip

Thermometer connections M8 thermometer option No No

Dimensions

KW [mm] 110 110 110 110 120 130 157 190 230 255

RL [mm] 180 180 180 205 220 225 280 350 375 400

VL [mm] 591 749 1009 675 690 875 967 920 1125 1150

Z [mm] 498 522 632 1050 1115 1120 1227 1240 1425 1450

WW [mm] 681 839 1099 1460 1528 1630 1855 1800 1860 2005

E-HZG [mm] 520 600 800 850 915 920 1032 1016 1200 1225

Weight [kg] 59 74 89 136 162 189 280* 373* 460* 560*

* Weight without insulation** In order to achieve the specified NL number, the boiler output must be higher than the specified continuous output.*** Operating media for heat exchanger: water in liquid state only.

Dom

estic

wat

er s

tora

ge ta

nks

Page 28: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

28 I Domestic water storage tanks

Domestic water storage tank HLS-Plus

Price / order number

Hot water (WW)

Internal Return flow (RL i)

External Return flow (RL a)

Internal Inlet flow (VL i)

Magnesium anode

Circulation (Z)

External Inlet flow (VL a)

Cold water (KW)

Inspection flange with optional connection for additional heat sources (RFL)

Foot ring

Storage type HLS-Plus 150 200 301 401 501 801

Price

Storage tank without insulation [€/item] - - - - - 2853,-

Storage tank with insulation [€/item] 983,- 1095,- 1542,- 1904,- 2022,- -

Fleece insulation [€/item] - - - - - 651,-

Order number

Storage tank without insulation - - - - - 26549

Storage tank with insulation RAL 9006 (only up to 500 l)

38090 38091 38092 38093 38094 -

Fleece insulation RAL 9006 - - - - - 28588

Product description» Material: S235JR+N steel, internal enamelled, external primer coat» Compressive strenght: 10 bar» Technical features: double bare-tube heat exchanger from 300 Litres (equal tube length inside / outside, operating modes of heat exchanger pair: parallel mode / single mode / series mode), Magnesium protection anode 1¼“ (from 800 Litres impessed current anode), Sensor clamping strip, Inspection flange 180 x 110 x LK 150 » Connections: Standard 1½“ sleeve for retrofitting an electric heating, flat-sealing external threads» Insulation: 100 mm polyline fleece insulation including base and lid insulation» SVGW certified: HLS-Plus 150 - 501 l (No. 1103-5831)» Energy efficiency class "B" until 500 Litres on request» Accessories: are on the pages 90 to 97

Note: Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water. See Pages 10/11, Installation instructions!

SVGW certified

Suitable for1:

Pellet heating

Condensing power plant

Oil heating plant

Gas plant

Direct heating system

Drinking water

Heater

1) Special solutions such as the combination of various heat sources also allow for other applications.

Heating pump system

Page 29: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 29

Technical data

* In order to achieve the specified NL number, the boiler output must be higher than the specified continuous output.** Operating media for heat exchanger: water in liquid state only.

Storage type HLS-Plus 150 200 301 401 501 801

Contents [Litres] 150 200 300 400 500 800

Energy efficiency class

Heat retaining loss (with insulation)

[Watt] 74 83 92 102 112 135

Diameter without insulation [mm] 500 500 600 650 650 800

Diameter with insulation [mm] 700 700 800 850 850 1000

Insulation [mm] 100 100 100 100 100 100

Height with insulation [mm] 1022 1285 1340 1610 1835 1872

Tilted height [mm] 1000 1250 1380 1580 1800 1850

Heating surface [m²] 1,5 2,0 3,8 (2 x 1,9) 5 (2 x 2,5) 5 (2 x 2,5) 6,0 (2 x 3,0)

Water Contents WT [Litres] 9,4 12,6 25 (2 x 12,5) 32 (2 x 16) 32 (2 x 16) 38 (2x19)

Flow rate WT [m³/h] 1,7 2,3 3,6 3,8 4,0 4,0

Pressure loss WT Series / Parallel / Single

[mbar] 60 130 680/85/200 720/100/320 750/110/350 830/120/420

NL number* according to DIN 4708 2,8 5,1 19,2 27,3 35 37

Continuous output according to DIN 4708 (10°/80°/45°)

[l/h](kW)

980 (39,9)

1350(55,0)

2200(89,6)

2500(101,8)

2500(101,8)

2500(101,8)

max. T/ max. P - TW [°C/bar] 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10

max. T/ max. P - GWT-HZG** [°C/bar] 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25

Cold water / hot water AG (KW/WW)

[Inch] G 1 G 1 G 1 G 1 G 1 G 1

Circulation AG (Z) [Inch] G¾ G¾ G¾ G¾ G¾ G¾

Heat exchanger AG (Vl i,a) [Inch] G 1 G 1 G 1 G 1 G 1 G 1

Heat exchanger AG (RL i,a) [Inch] G 1 G 1 G 1 G 1 G 1 G 1

Electric heating for all storage tanks: possible via inspection flange

Nominal width of control flange (RFL) DN 110 DN 110 DN 110 DN 110 DN 110 DN 110

Sensor/controller connections for all storage tanks: Sensor clamping strip variable positioning

Thermometer connections No No No No No No

Dimensions

KW [mm] 110 110 120 130 130 164

RL (i) [mm] 180 180 218 227 227 261

RL (a) [mm] - - 301 310 310 344

Z [mm] 522 522 706 802 802 776

VL (a) [mm] - - 829 940 940 914

VL (i) [mm] 700 875 966 1151 1151 1051

WW [mm] 836 1099 1196 1404 1630 1638

Weight [kg] 78 97 158 212 227 370

Did you know that......The extra large bare-tube heat exchangers are responsible for a high transferring capacity. This enables the storage tank to be quickly loaded and for the heat transfer from the heat pumps to be optimized. A marked lowering of the return flow temperature also considerably raises the condensing effect of condensing boilers.

Dom

estic

wat

er s

tora

ge ta

nks

Page 30: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

30 I Domestic water storage tanks

Domestic water storage tank PSB

Price / order number

Storage type PSB 200 300 400 500 500 750 1000 1500 2000

Price Ø=600 Ø=650

Storage tank without insulation [€/item] - - - - - 1737,- 2168,- 3286,- 4025,-

Storage tank with insulation [€/item] 1117,- 1280,- 1484,- 1643,- 1705,- - - - -

Fleece insulation [€/item] - - - - - 638,- 748,- 913,- 1191,-

Order number

Storage tank without insulation - - - - - 17160 17161 21812 21823

Storage tank with insulation RAL 9006 (only up to 500 l)

39086 39087 39001 39009 39015 - - - -

Fleece insulation RAL 9006 - - - - - 28469 28470 28471 28472

Connection (A2)

Sensor/controller connections (F1)

Connection (A1)

Foot ring

Inspection flange with optional connection for additional heat sources (RFL)

Product description» Material: S235JR+N steel, internal enamelled, external primer coat » Compressive strenght: 10 bar» Technical features: Magnesium protection anode 1¼“ , inspection opening 280 x 200 x LK 245» Connections: flat-sealing external threads» Insulation: 100 mm polyline fleece insulation including base and lid insulation» on request up to 5.000 liters possible» Energy efficiency class "B" until 500 Litres on request» Accessories: are on the pages 90 to 97

Note: Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water. See Pages 10/11, Installation instructions!

Suitable for1:

Pellet heating

Condensing power plant

Oil heating plant

Gas plant

Direct heating system

Drinking water

Heater

1) Special solutions such as the combination of various heat sources also allow for other applications.

Page 31: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 31

Technical data

* Weight without Insulation

Storage type PSB 200 300 400 500 500 750 1000 1500 2000Ø=600 Ø=650

Contents [Litres] 200 300 400 500 500 750 1000 1500 2000

Energy efficiency class

Heat retaining loss (with insulation)

[Watt] 83 92 102 112 112 131 145 168 186

Diameter without insulation [mm] 550 550 600 600 650 750 850 1000 1100

Diameter with insulation [mm] 750 750 800 800 850 950 1050 1200 1300

Insulation [mm] 100 100 100 100 100 100 100 100 100

Height with insulation [mm] 1070 1550 1630 1980 1790 1970 2010 2250 2410

Tilted height [mm] 1080 1550 1590 1920 1750 1945 2090 2260 2440

max. T/ max. P - TW [°C/bar] 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10

Loading/unloading connections AG (A1, A2)

[Inch] G1 G1 G1 G1 ¼ G1 ½ G1 ¼ G1 ¼ G2 G2

Electric heating for all storage tanks: possible via inspection flange

Nominal width of control flange (RFL)

DN 200 DN 200 DN 200 DN 200 DN 200 DN 200 DN 200 DN 200 DN 200

Sensor/controller connections (F1-F3)

[Inch] Rp ¾ Rp ¾ Rp ¾ Rp ¾ Rp ¾ Rp ¾ Rp ¾ Rp ¾ Rp ¾

Thermometer connections (F1-F3)

[Inch] Rp ¾ Rp ¾ Rp ¾ Rp ¾ Rp ¾ Rp ¾ Rp ¾ Rp ¾ Rp 3/4“

Ventilation [Inch] Rp ¾ Rp ¾ Rp ¾ Rp ¾ Rp ¾ Rp ¾ Rp ¾ Rp ¾ Rp 3/4“

Anode optionally (ANO 1) [Inch] - 1 ¼ 1 ¼ 1 ¼ 1 ¼ 1 ¼ 1 ¼ 1 ¼ 1 ¼

Anode optionally (ANO 2) [Inch] 1 ¼ 1 ¼ 1 ¼ 1 ¼ 1 ¼ 1 ¼ 1 ¼ 1 ¼ 1 ¼

Dimensions

A1 [mm] 215 215 245 245 245 265 285 340 365

RFL, F1 [mm] 320 320 350 350 350 370 390 445 470

ANO 1 [mm] - 570 600 600 600 620 640 645 670

F 2 [mm] 550 820 850 980 850 950 920 1100 1185

ANO 2 [mm] 690 1170 1200 1530 1365 1500 1470 1760 1905

A2, F3 [mm] 790 1270 1300 1630 1465 1600 1570 1860 2005

Weight [kg] 90 118 129 160 160 225* 305* 390* 485*

Dom

estic

wat

er s

tora

ge ta

nks

Page 32: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

32 I Domestic water storage tanks

Domestic water storage tank HSO

Price / order number

Storage type HSO 120 150

Price

Storage tank with insulation [€/item] 950,- 1030,-

Order number

Storage tank with insulation RAL 9006 37387 38328

Cold water (KW)

Return flow (RL)

Inlet flow (VL)

Circulation (Z)Hot water (WW)

Draining

Product description» Material: S235JR+N steel, internal enamelled, external primer coat » Compressive strenght: 10 bar» Technical features: Bar-tube heat exchanger, Magnesium protection anode M8, Sensor sleeve, Levelling feets, Inspection flange 210 x 150 x LK 180 (top)» Connections: at the top of the storage tank, flat-sealing external threads» Insulation: 50 mm PU rigid foam insulation with Sky-coating» HSO 120 Litres in Energy efficiency class "B" on request» Accessories: are on the pages 90 to 97

Note: Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water. See Pages 10/11, Installation instructions!

Suitable for1:

Pellet heating

Condensing power plant

Oil heating plant

Gas plant

Direct heating system

Drinking water

Heater

1) Special solutions such as the combination of various heat sources also allow for other applications.

Page 33: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 33

Technical data

* Insulation not removable** In order to achieve the specified NL number, the boiler output must be higher than the specified continuous output.*** Operating media for heat exchanger: water in liquid state only.

Storage type HSO 120 150

Contents [Litres] 120 150

Energy efficiency class

Heat retaining loss (with insulation) [Watt] 69 73

Diameter without insulation [mm] 500* 500*

Diameter with insulation [mm] 600 600

Insulation [mm] 50* 50*

Height with insulation [mm] 835 1010

Tilted height [mm] 1045 1160

Heating surface [m²] 1,0 1,3

Water Contents WT [Litres] 7,5 8,2

Flow rate WT [m³/h] 1,7 1,9

Pressure loss WT [mbar] 100 120

NL number** according to DIN 4708 1,8 2,1

Continuous output according to DIN 4708(10°/80°/45°)

[l/h](kW)

800 (33) 920 (38)

max. T/ max. P - TW [°C/bar] 95 / 10 95 / 10

max. T/ max. P - GWT-HZG*** [°C/bar] 160 / 25 160 / 25

Cold water / hot water AG (KW/WW) [Inch] G ¾ G ¾

Circulation AG (Z) [Inch] G ¾ G ¾

Heat exchanger AG (VL/RL) [Inch] G ¾ G ¾

Electric heating for all storage tanks: not possible

Nominal width of control flange (RFL) DN 110 DN 110

Sensor/controller connections(F) for all storage tanks: immersion sleeve, Di = 9 mm

Thermometer connections for all storage tanks: not available

Draining (EL) Rp ½ Rp ½

Weight [kg] 88 93

Did you know that...... The compact design of low-height storage tanks is often a reason for them being installed when flats are modernized. The floor-standing system storage tank is eminently suited for combination with all wall-suspended gas condensing devices.

Dom

estic

wat

er s

tora

ge ta

nks

Page 34: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

34 I Domestic water storage tanks

Domestic water storage tank WWS-TS

Price / order number

Storage type WWS-TS 120 150 200

Price

Storage tank with insulation [€/item] 1274,- 1325,- 1631,-

Order number

Storage tank with insulation RAL 9006 16818 16822 16826

Hot water (WW) Thermometer

Anode (M8)Sensor/controller

connections

Inlet flow (VL) / Return flow (RL)

Circulation (Z)

Cold water (KW)

Levelling feet

Product description» Material: S235JR+N steel, internal enamelled, external primer coat » Compressive strenght: 10 bar» Technical features: large bare-tube heat exchanger, Magnesium protection anode M8, Immersion sleeve, Levelling feet, Inspection flange 180 x 110 x LK 150, Capillary remote-reading thermometer» Connections: flat-sealing external threads» Insulation: PU rigid foam insulation with coating made of paint- coated steel plate» loadable with 280 kg within the load area***» WWS-TS 120 Litres in Energy efficiency class "B" on request» Accessories: are on the pages 90 to 97

Note: Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water. See Pages 10/11, Installation instructions!

Suitable for1:

Pellet heating

Condensing power plant

Oil heating plant

Gas plant

Direct heating system

Drinking water

Heater

1) Special solutions such as the combination of various heat sources also allow for other applications.

Page 35: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 35

Technical data

Storage type WWS-TS 120 150 200

Contents [Litres] 120 150 200

Energy efficiency class

Heat retaining loss (with insulation) [Watt] 69 73 84

Height x width x length with Insulation [mm] 570 x 610 x 820* 570 x 610 x 965* 660 x 700 x 990*

Insulation [mm] - - -

Heating surface [m²] 0,76 0,76 0,9

Water Contents WT [Litres] 5,0 5,0 5,7

Flow rate WT [m³/h] 1,0 1,0 1,1

Pressure loss WT [mbar] 80 80 90

NL number** according to DIN 4708 1,5 2 2,3

Continuous output according to DIN 4708 (10°/80°/45°)

[l/h](kW)

610 (24,8) 610 (24,8) 640 (26,0)

max. T/ max. P - TW [°C/bar] 95 / 10 95 / 10 95 / 10

max. T/ max. P - GWT-HZG [°C/bar] 110 / 16 110 / 16 110 / 16

Cold water / hot water (KW/WW) [Inch] R ¾ R ¾ R ¾

Circulation (Z) [Inch] R ¾ R ¾ R ¾

Heat exchanger (VL/RL) [Inch] R ¾ R ¾ R ¾

Electric heating for all storage tanks: not possible

Nominal width of control flange (RFL) for all storage tanks: DN 110

Sensor/controller connections(F) for all storage tanks: immersion sleeve, Di = 9 mm

Thermometer connections for all storage tanks: Capillary remote-read thermometer

Weight [kg] 84 96 113

* Insulation not removable** In order to achieve the specified NL number, the boiler output must be higher than the specified continuous output.*** min. 4 supporting points within the load area: longitudinal on a 150-200 mm strip from the centre axis, transverse 100 mm from the outer edge

Dom

estic

wat

er s

tora

ge ta

nks

Page 36: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

36 I Buffer storage tanks

© panthermedia.net / Igor Yaruta

Huch buffer storage tankThe all-rounder among the storage tanksOur buffer storage tanks are used as the central unit in modern heating systems. It stores excess heat and offsets any temperature variations. It makes older retrofitted heating systems efficient again and saves you money. It can be used for domestic water preparation in combination with a fresh water station.

Page 37: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 37

High-grade bare-tube heat exchangersThanks to a special heat exchanger design and arrange-ment a high extraction grade of up to 96% is achieved.

Optimum temperature stratificationStratification guiding channels and baffle plates ensure that temperature swirls in the storage tank are reduced.

Connection stubsOur connection stubs are a standard 50 mm in length. The fleece insulation thus insulates any non-used connections. This cuts radiation losses and an improved energy efficiency is achieved by the storage tank.

Manifold connection scopeOur buffer storage tanks have a host of connections. This makes possible an optimum system attachment for the most varied of applications.

Use of the entire storage tank capacityAn optimum hot water connection at the top of the sto-rage tank means that the storage tank capacity is fully utilised.

Flexible positioning of the temperature sensorsSensor clamping strips allow the temperature sensor to be positioned at will. As a result, the Huch storage tanks are suitable for many application fields.

Innovative highly efficient storage tank insulationThe high-grade Polyline© fleece insulation incl. a 100 mm lid and a 50 mm base insulation reduces heat loss by 10-15 % over soft foam.

Universally deployableFor system applications in association with regenerative heat generators and fresh water stations.

1

2

3

4

5

6

The SPSX-2G buffer storage tank is shown in the illustration.

1

4

3

2

7

8

7

5

Quality features

Connection scheme

Schematic diagram – relevant standards and regulations must be observed!

Cold water

FRIWA

Wood heating

Buff

er s

tora

ge ta

nks

Page 38: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

38 I Buffer storage tanks

Buffer storage tank SPSX / SPSX-F

Price / order number

Connection (A4)

Connection (A3)

Connection (A2)

Connection (A1)

only SPSX-F:Inspection flange with optional connection for additional heat sources (RFL)

Foot ring

Electric heating

stratified guide channels

Storage type SPSX/SPSX-F 200 300 400 500 600 800 850 1000 1000 1100 1500 1650 2000 2200 3000

Price Ø=790 Ø=850

SPSX without insulation [€/item] - - - - 699,- 726,- 741,- 792,- 805,- 860,- 1106,- 1410,- 1480,- 1630,- 4005,-

SPSX-F without insulation [€/item] - - - - 894,- 944,- 954,- 987,- 1000,- 1080,- 1307,- 1547,- 1650,- 1805,- 4328,-

SPSX with insulation RAL 9006

[€/item] 814,- 924,- 1038,- 1057,- - - - - - - - - - - -

SPSX-F with insulation RAL 9006

[€/item] 1009,- 1119,- 1260,- 1299,- - - - - - - - - - - -

Fleece insulation [€/item] - - - - 554,- 568,- 607,- 619,- 713,- 729,- 995,- 1038,- 1111,- 1170,- 1226,-

Order number

SPSX without insulation - - - - 22455 22473 22486 22501 23886 22512 22522 22532 22541 22550 22559

SPSX-F without insulation - - - - 23630 23634 23638 23642 23906 23646 23653 23658 23662 23666 23670

SPSX with insulation RAL 9006

38124 38125 38126 38127 - - - - - - - - - - -

SPSX-F with insulation RAL 9006

38128 38129 38130 38131 - - - - - - - - - - -

Fleece insulation RAL 9006

- - - - 28529 28530 28531 28532 28533 28534 28535 28536 28537 28538 28539

Note: Illustration shows SPSX-F. SPSX is supplied without flange. Flanges are optionally available at extra charge; they stand for the "F" in SPSX-F.

E-HZG

B2

B2

Product description» Material: S235JR+N steel, internal uncoated, external primer coat » Compressive strenght: 3 bar» Technical features: 2 stratified guide channels, Sensor clamping strip, Electric heating sleeve 1 ½“» SPSX 800 and 1000 (Ø 790 / Ø 850 mm) with attachment points B1/B2 (B1 to support our freshwater module or modules from other manufacturers by the universal assembly plate, B2 optionally for other modules (freshwater or solar station))» optionally for extra charge: Flange 280 x 200 x LK 245 for inpection or for the installation of a finned tube heat exchanger» Insulation: 100 mm polyline fleece insulation including base and lid insulation» SVGW certified: SPSX 600 - 1500 l (No. 1110-5928)» Accessories: are on the pages 90 to 97

Note: Planning and setting up the heating system on the basis of the technical guidelines to avoid oxygen-induced corrosion in keeping with VDI and DIN specifications. See Pages 10/11, Installation instructions!

for freshwater modules

SVGW certified

Suitable for1:

Heater

Wood burning plant /Wood chip heating

Pellet heating

Solar heating plant

Biomass plant /Biogas plant

Combined heat and power plant

1) Special solutions such as the combination of various heat sources also allow for other applications.

Page 39: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 39

Technical data

* Weight (kg) = installation weight (for version SPSX-F +13 Kg)

Storage type SPSX/SPSX-F 200 300 400 500 600 800 850 1000 1000 1100 1500 1650 2000 2200 3000Ø=790 Ø=850

Contents [Litres] 200 300 400 500 600 800 850 1000 1000 1100 1500 1650 2000 2200 3000

Energy efficiency class - -

Heat retaining loss (with insulation)

[Watt] 83 92 102 112 121 134 138 145 145 151 168 174 186 - -

Diameter without insulation

[mm] 550 550 600 650 700 790 790 790 850 850 1000 1100 1100 1150 1150

Diameter with insulation [mm] 750 750 800 850 900 990 990 990 1050 1050 1200 1300 1300 1350 1350

Insulation [mm] 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100

Height with insulation [mm] 1070 1550 1610 1720 1831 1802 1970 2202 2000 2160 2130 1980 2380 2360 3130

Tilted height [mm] 1050 1530 1570 1690 1800 1780 1950 2180 2000 2165 2150 2050 2420 2420 3140

max. T/ max. P [°C/bar] 95/3 95/3 95/3 95/3 95/3 95/3 95/3 95/3 95/3 95/3 95/3 95/3 95/3 95/3 95/3

Loading/unloading connections (A1 to A4)

[Inch] for all storage tanks: Rp 1½

Electric heating height A3 [Inch] for all storage tanks: Rp 1½

Electric heating (only SPSX-F) for all storage tanks: possible via inspection flange

Inspection flange (RFL) (only SPSX-F)

for all storage tanks: DN 200

Sensor/controller connections for all storage tanks: Sensor clamping strip

Ventilation [Inch] for all storage tanks: Rp 1¼

Dimensions

A1 [mm] 215 215 225 245 246 246 263 246 280 285 320 335 335 345 345

RFL [mm] 320 320 330 350 351 351 368 351 385 390 425 440 440 450 450

A2 [mm] 405 560 585 645 646 646 718 786 735 790 786 748 875 875 1135

A3 [mm] 595 905 945 1045 1046 1046 1173 1326 1195 1295 1253 1161 1415 1405 1925

A4 [mm] 785 1245 1315 1405 1496 1446 1633 1866 1650 1805 1720 1575 1975 1945 2715

Weight * [kg] 48 66 74 87 102 114 122 137 136 144 193 229 263 288 355

Did you know that...... Now and again the space involved is such that a large-capacity buffer storage tank fails to fit into the boiler room and the capacity needs to be split between two buffer storage tanks. Buffer storage tank connectors permit two evenly-sized storage tanks of the SPSX and PSX buffer storage tank types to be easily, rapidly and securely attached.

Buffer storage tank connectionstainless steel corrugated pipe DN32 / length: 300 mm mit 1x 1½" ÜWM, DN 1x 1½" AG

Order-No.: 46771 Price [€/item]: 57,-

Buff

er s

tora

ge ta

nks

Page 40: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

40 I Buffer storage tanks

Buffer storage tank SPSX-G / SPSX-2G

Price / order number

Inlet flow (VL2)

Return flow (RL2)

Inlet flow (VL1)

Return flow (RL1)Connection (A1)

Connection (A2)

Connection (A3) / E-HZG

Connection (A4)

Foot ring

Storage type SPSX-G / SPSX-2G 500 600 800 850 1000 1000 1100 1500 2000

Price Ø=790 Ø=850

SPSX-G without insulation [€/item] - 975,- 1020,- 1055,- 1110,- 1150,- 1185,- 1520,- 1830,-

SPSX-2G without Insulation [€/item] - 1131,- 1176,- 1211,- 1298,- 1338,- 1373,- 1708,- 2018,-

SPSX-G with insulation [€/item] 1350,- - - - - - - - -

SPSX-2G with insulation [€/item] 1490,- - - - - - - - -

Fleece insulation [€/item] - 554,- 568,- 607,- 619,- 713,- 729,- 995,- 1111,-

Order number

SPSX-G without Insulation - 22577 22582 22587 22592 23901 22597 22602 27955

SPSX-2G without Insulation - 25995 26000 26005 26010 26015 26021 26026 28313

SPSX-G with insulation RAL 9006 38132 - - - - - - - -

SPSX-2G with insulation RAL 9006 38133 - - - - - - - -

Fleece insulation RAL 9006 - 28529 28530 28531 28532 28533 28534 28535 28537

Stratified guide channels

Product description» Material: S235JR+N steel, internal uncoated, external primer coat » Compressive strenght: 3 bar» Technical features: optionally with one or two bare-tube heat exchanger, Stratified guide channels, Sensor clamping strip, Electric heating sleeve 1 ½“» SPSX 800 and 1000 (Ø 790 / Ø 850 mm) with attachment points B1/B2 (B1 to support our freshwater module or modules from other manufacturers by the universal assembly plate, B2 optionally for other modules (freshwater or solar station))» Insulation: 100 mm polyline fleece insulation including base and lid insulation» Accessories: are on the pages 90 to 97

Note: Planning and setting up the heating system on the basis of the technical guidelines to avoid oxygen-induced corrosion in keeping with VDI and DIN specifications. See Pages 10/11, Installation instructions!

for freshwater modules

Suitable for1:

Heater

Wood burning plant /Wood chip heating

Pellet heating

Solar heating plant

Biomass plant /Biogas plant

Combined heat and power plant

1) Special solutions such as the combination of various heat sources also allow for other applications.

Note: Illustration shows SPSX-2G.

Page 41: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 41

Technical data

Storage type SPSX-G / SPSX-2G 500 600 800 850 1000 1000 1100 1500 2000Ø=790 Ø=850

Contents [Litres] 500 600 800 850 1000 1000 1100 1500 2000

Energy efficiency class

Heat retaining loss (with insulation)

[Watt] 112 121 134 138 145 145 151 168 186

Diameter without insulation [mm] 650 700 790 790 790 850 850 1000 1100

Diameter with insulation [mm] 850 900 990 990 990 1050 1050 1200 1300

Insulation [mm] 100 100 100 100 100 100 100 100 100

Height with insulation [mm] 1720 1831 1802 1970 2202 2000 2160 2130 2380

Tilted height [mm] 1690 1800 1780 1950 2180 2000 2165 2150 2420

Heating surface top/bottom [m²] 1,1 / 2,15 1,3 / 2,5 1,4 / 2,5 1,4 / 2,5 2,0 / 3,2 2,1 / 3,2 2,1 / 3,2 2,15 / 4,25 2,15 / 4,25

Water content WT top/bottom [Litres] 7,0 / 13,5 8,2 / 15,7 8,8 / 15,7 8,8 / 15,7 12,6 / 20,1 13,2 / 20,1 13,2 / 20,1 13,5 / 26,7 13,5 / 26,7

max. T/ max. P - Storage tank [°C/bar] 95 / 3 95 / 3 95 / 3 95 / 3 95 / 3 95 / 3 95 / 3 95 / 3 95 / 3

max. T/ max. P - GWT-HZG [°C/bar] 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25

Heat exchanger (VL/RL) [Inch] G 1 A G 1 A G 1 A G 1 A G 1 A G 1 A G 1 A G 1 A G 1 A

Loading/unloading connections (A1 to A4)

[Inch] Rp 1½ Rp 1½ Rp 1½ Rp 1½ Rp 1½ Rp 1½ Rp 1½ Rp 1½ Rp 1½

Electric heating height A3 [Inch] Rp 1½ Rp 1½ Rp 1½ Rp 1½ Rp 1½ Rp 1½ Rp 1½ Rp 1½ Rp 1½

Sensor/controller connections for all storage tanks: Sensor clamping strip

Thermometer connections for all storage tanks: M8 thermometer option

Ventilation [Inch] Rp 1¼ Rp 1¼ Rp 1¼ Rp 1¼ Rp 1¼ Rp 1¼ Rp 1¼ Rp 1¼ Rp 1¼

Dimensions

A1, RL1 [mm] 245 246 246 263 246 280 285 320 335

A2 [mm] 645 646 646 718 786 735 790 786 875

VL1 [mm] 870 896 816 833 946 980 985 1020 1035

A3, E-HZG [mm] 1045 1046 1046 1173 1326 1195 1295 1253 1415

RL2 only SPSX-2G [mm] 1095 1096 1096 1223 1376 1245 1345 1303 1515

VL2 only SPSX-2G [mm] 1385 1436 1386 1513 1806 1615 1715 1653 1865

A4 [mm] 1405 1496 1446 1633 1866 1650 1805 1720 1975

Weight* [kg] 120/137 140/160 152/173 160/181 186/216 185/217 193/225 257/290 328/361

* Weight (kg) = installation weight** B1 to support our freshwater module, or modules of other manufacturers by means of our universal assembly plate, B2 optionally for other modules (freshwater or solar)

Buff

er s

tora

ge ta

nks

Page 42: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

42 I Buffer storage tanks

Buffer storage tank PSX / PSX-F

Price / order number

Connection (A4)

Connection (A3)

Connection (A2)

Connection (A1)

only PSX-F:Inspection flange with optional connection for additional heat sources (RFL)

Foot ring

Storage type PSX/PSX-F 200 300 400 500 600 800 850 1000 1000 1100 1500 1650 2000 2200 3000

Price Ø=790 Ø=850

PSX without Insulation [€/item] - - - - 679,- 717,- 739,- 782,- 797,- 828,- 1067,- 1358,- 1420,- 1580,- 3950,-

PSX-F without Insulation [€/item] - - - - 874,- 912,- 934,- 954,- 970,- 1050,- 1262,- 1518,- 1601,- 1775,- 4145,-

PSX with insulation [€/item] 776,- 889,- 1009,- 1039,- - - - - - - - - - - -

PSX-F with insulation [€/item] 971,- 1084,- 1240,- 1280,- - - - - - - - - - - -

Fleece insulation [€/item] - - - - 554,- 568,- 607,- 619,- 713,- 729,- 995,- 1038,- 1111,- 1170,- 1226,-

Order number

PSX without Insulation - - - - 19886 15433 17569 13305 23932 17572 13484 17364 14417 17370 17317

PSX-F without Insulation - - - - 31824 13884 17812 15434 25386 17971 14433 19140 16429 19305 19435

PSX with insulation RAL 9006 38114 38116 38117 38118 - - - - - - - - - - -

PSX-F with insulation RAL 9006 38119 38120 38121 38122 - - - - - - - - - - -

Fleece insulation RAL 9006 - - - - 28529 28530 28531 28532 28533 28534 28535 28536 28506 28507 28508

Product description

Note: Illustration shows PSX-F. PSX is supplied without flange. Flanges are optionally available at extra charge; they stand for the "F" in PSX-F.

Suitable for1:

Heater

Wood burning plant /Wood chip heating

Pellet heating

Solar heating plant

Biomass plant /Biogas plant

Combined heat and power plant

1) Special solutions such as the combination of various heat sources also allow for other applications.

» Material: S235JR+N steel, internal uncoated, external primer coat » Compressive strenght: 3 bar» Technical features: Sensor clamping strip» optionally for extra charge: Flange 280 x 200 x LK 245 for inpection or for the installation of a finned tube heat exchanger» Insulation: 100 mm polyline fleece insulation including base and lid insulation» Accessories: are on the pages 90 to 97

Note: Planning and setting up the heating system on the basis of the technical guidelines to avoid oxygen-induced corrosion in keeping with VDI and DIN specifications. See Pages 10/11, Installation instructions!

Page 43: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 43

Technical data

Storage type PSX/PSX-F 200 300 400 500 600 800 850 1000 1000 1100 1500 1650 2000 2200 3000Ø=790 Ø=850

Contents [Litres] 200 300 400 500 600 800 850 1000 1000 1100 1500 1650 2000 2200 3000

Energy efficiency class - -

Heat retaining loss (with insulation)

[Watt] 83 92 102 112 121 134 138 145 145 151 168 174 186 - -

Diameter without insulation [mm] 550 550 600 650 700 790 790 790 850 850 1000 1100 1100 1150 1150

Diameter with insulation [mm] 750 750 800 850 900 990 990 990 1050 1050 1200 1300 1300 1350 1350

Insulation [mm] 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100

Height with insulation [mm] 1070 1550 1610 1720 1811 1802 1970 2202 2000 2160 2130 1980 2410 2360 3160

Tilted height [mm] 1050 1530 1570 1710 1810 1780 1990 2180 2000 2165 2150 2080 2450 2430 3170

max. T/ max. P - HZG [°C/bar] 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3

Loading/unloading connections (A1 to A4)

[Inch] for all storage tanks: Rp 1½

Electric heating (only PSX-F) for all storage tanks: possible via inspection flange

Inspection flange (RFL) (only PSX-F)

for all storage tanks: DN 200

Sensor/controller connections for all storage tanks: Sensor clamping strip

Thermometer connections for all storage tanks: M8 thermometer option

Ventilation IG [Inch] for all storage tanks: Rp 1¼

Dimensions

A1 [mm] 215 215 225 245 246 246 263 246 280 285 320 335 365 345 375

RFL [mm] 320 320 330 350 351 351 368 351 385 390 425 440 470 450 480

A2 [mm] 405 560 585 645 646 646 718 786 735 790 786 748 905 875 1165

A3 [mm] 595 905 945 1045 1046 1046 1173 1326 1195 1295 1253 1161 1445 1405 1955

A4 [mm] 785 1245 1315 1405 1496 1446 1633 1866 1650 1805 1720 1575 1985 1945 2745

Weight* [kg] 46 63 71 83 98 110 118 132 132 139 189 225 258 283 349

* Weight (kg) = installation weight (for version PSX-F +13 Kg)

Buff

er s

tora

ge ta

nks

Page 44: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

44 I Buffer storage tanks

Buffer storage tank PSX-GWT

Price / order number

Connection (A4)

Connection (A3)

Connection (A2)

Connection (A1)Return flow (RL)

Inlet flow (VL)

Foot ring

Storage type PSX-GWT 500 600 800 850 1000 1100 1500 2000

Price

Storage tank without insulation [€/item] - 933,- 990,- 1020,- 1084,- 1165,- 1470,- 1790,-

Storage tank with insulation [€/item] 1303,- - - - - - - -

Fleece insulation [€/item] - 554,- 568,- 607,- 619,- 729,- 995,- 1111,-

Order number

Storage tank without insulation - 19893 16435 17713 16440 17717 16445 18334

Storage tank with insulation RAL 9006 (only500 l)

38123 - - - - - - -

Fleece insulation RAL 9006 - 34674 28511 28512 28513 28514 28517 28518

Product description» Material: S235JR+N steel, internal uncoated, external primer coat » Compressive strenght: 3 bar» Technical features: large bare-tube heat exchanger, Sensor clamping strip» Insulation: 100 mm polyline fleece insulation including base and lid insulation» Accessories: are on the pages 90 to 97

Note: Planning and setting up the heating system on the basis of the technical guidelines to avoid oxygen-induced corrosion in keeping with VDI and DIN specifications. See Pages 10/11, Installation instructions!

Suitable for1:

Heater

Wood burning plant /Wood chip heating

Pellet heating

Solar heating plant

Biomass plant /Biogas plant

Combined heat and power plant

1) Special solutions such as the combination of various heat sources also allow for other applications.

Page 45: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 45

Technical data

* Weight (kg) = installation weight

Storage type PSX-GWT 500 600 800 850 1000 1100 1500 2000

Contents [Litres] 500 600 800 850 1000 1100 1500 2000

Energy efficiency class

Heat retaining loss (with insulation)

[Watt] 112 121 134 138 145 151 168 186

Diameter without insulation

[mm] 650 700 790 790 790 850 1000 1100

Diameter with Insulation

[mm] 850 900 990 990 990 1050 1200 1300

Insulation [mm] 100 100 100 100 100 100 100 100

Height with insulation [mm] 1720 1811 1802 1970 2202 2160 2130 2410

Tilted height [mm] 1710 1810 1780 1990 2180 2165 2150 2450

Heating surface [m²] 2,5 2,5 2,5 2,5 3,2 3,2 4,25 4,25

Water Content WT [Litres] 15,7 15,7 15,7 15,7 20,1 20,1 26,7 26,7

max. T/ max. P - Storage [°C/bar] 95 / 3 95 / 3 95 / 3 95 / 3 95 / 3 95 / 3 95 / 3 95 / 3

max. T/ max. P - GWT-HZG [°C/bar] 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25

Heat exchanger (VL/RL) [Inch] AG 1 AG 1 AG 1 AG 1 AG 1 AG 1 AG 1 AG 1

Loading/unloading connections (A1 to A4)

[Inch] Rp 1½ Rp 1½ Rp 1½ Rp 1½ Rp 1½ Rp 1½ Rp 1½ Rp 1½

Electric heating for all storage tanks: not possible

Sensor/controller connections for all storage tanks: Sensor clamping strip

Thermometer connections for all storage tanks: M8 thermometer option

Ventilation [Inch] Rp 1¼ Rp 1¼ Rp 1¼ Rp 1¼ Rp 1¼ Rp 1¼ Rp 1¼ Rp 1¼

Dimensions

A1, RL [mm] 245 246 246 263 246 285 320 365

A2 [mm] 645 646 646 718 786 790 786 905

VL [mm] 870 896 816 833 946 985 1020 1065

A3 [mm] 1045 1046 1046 1173 1326 1295 1253 1445

A4 [mm] 1405 1496 1446 1633 1866 1805 1720 1985

Weight* [kg] 116 136 148 156 181 189 262 323

Buff

er s

tora

ge ta

nks

Page 46: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

46 I System products

© panthermedia.net / Ingrid Balabanova

Page 47: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 47

Almost 90 % of the energy in private households is needed for hot water generation and heating. Thanks to individual components adapted to each other, we can provide you with an all-round, care-free package for an up-to-date and energy-efficient heating system. For you, this means the best-possible energy utilization and maximum fail-safe operations from the start.

System products for our Huch storage tanksGet fit for the future.

Fresh water stations for our buffer storage tank

Small heating pumps for our domestic water storage tanks

Energy control center compact system solution for a high degree of convenience

Flexible installation - can be fitted directly at the storage tank or on the wall

Domestic water / drinking water

Solar station

Heating circuit groups

Space-saving and assembly-friendly compact unit

Assembly-friendlyCompact unit with fitted solar station, heating circuit assembly and installed fresh water station

Hygienically correctDomestic water preparation based on the throughput principle with a high degree of convenience

Energy-efficientFrom optimally adjusted connections for stratification of the return flows

» Domestic water based on the flow-through principle» Hygienic and efficient » Economical & long-lasting» No development of legionella» Compact dimensions» Easy and quick to install

Syst

em p

rodu

cts

Page 48: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

48 I System products

FRIWA TacoTherm Fresh Mega Connect

Product description

Price / order number

» Compact and ready-to-connect group of taps» Deployment in combination with our buffer storage tank (SPSX / SPSX-G / SPSX-2G 800 / 1000 litres)» Filling rate 40 l/min» Integrated safety group and soft-close taps» Optionally with or without circulation pump» Manifold possibilities for deployment detached houses and apartment blocks» For both new building construction and existing building revamping» Incl. assembly plate » Tubing set for storage tank assembly separately available

Note: Please refer to the buffer storage tank column for the specification on our buffer storage tanks.

800 1000 1000Price Ø=790 Ø=850

FRIWA TacoTherm Fresh Mega Connect [€/item] 1743,- 1743,- 1743,-FRIWA TacoTherm Fresh Mega Connect C (with Circulation) [€/item] 2259,- 2259,- 2259,-SPSX without insulation [€/item] 726,- 792,- 805,-SPSX-G without insulation [€/item] 1020,- 1110,- 1150,-SPSX-2G without insulation [€/item] 1176,- 1298,- 1338,-Fleece insulation RAL 9006 [€/item] 568,- 619,- 713,-Piping kit for storage tank [€/item] 360,- 360,- 360,-

Order numberFRIWA TacoTherm Fresh Mega Connect 46780 46780 46780FRIWA TacoTherm Fresh Mega Connect C (with Circulation) 46781 46781 46781SPSX without insulation 22473 22501 23886SPSX-G without insulation 22582 22592 23901SPSX-2G without insulation 26000 26010 26015Fleece insulation RAL 9006 28530 28532 28533Piping kit for storage tank 46785 46785 46785

Technical dataFRIWA TacoTherm Fresh Mega ConnectConnections primary /secondary (IG) [Inch] Rp 1Circulation (AG) [Inch] Rp 1max. T / max. P (TW) [°C/bar] 85 / 9WW output (KW 10° and WW 45°) - inlet flow temperature 75°C [l/min] 40Medium primary /secondary Heater water / Drinking waterHeat exchanger 26 plates / stainless steel 1.4401; copper-solderedDimensionsDimensions W x H x D (incl. insulation) [mm] 470 x 685 x 191

Page 49: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 49

Product description

FRIWA TacoTherm Fresh Mega2 X

Price / order number

» Compact and ready-to-connect group of taps» Deployment in combination with our buffer storage tank (SPSX / SPSX-G / SPSX-2G 800 / 1000 litres)» Filling rate 60 l/min» Integrated safety group and soft-close taps» Optionally with or without circulation pump» Manifold possibilities for deployment detached houses and apartment blocks» For both new building construction and existing building revamping» Incl. assembly plate » Tubing set for storage tank assembly separately available

Note: Please refer to the buffer storage tank column for the specification on our buffer storage tanks.

800 1000 1000Price Ø=790 Ø=850

FRIWA TacoTherm Fresh Mega2 X [€/item] 2652,- 2652,- 2652,-FRIWA TacoTherm Fresh Mega2 XC (with Circulation) [€/item] 3027,- 3027,- 3027,-SPSX without insulation [€/item] 726,- 792,- 805,-SPSX-G without insulation [€/item] 1020,- 1110,- 1150,-SPSX-2G without insulation [€/item] 1176,- 1298,- 1338,-Fleece insulation RAL 9006 [€/item] 568,- 619,- 713,-Piping kit for storage tank [€/item] 360,- 360,- 360,-

Order numberFRIWA TacoTherm Fresh Mega2 X 46782 46782 46782FRIWA TacoTherm Fresh Mega2 XC (with Circulation) 46783 46783 46783SPSX without insulation 22473 22501 23886SPSX-G without insulation 22582 22592 23901SPSX-2G without insulation 26000 26010 26015Fleece insulation RAL 9006 28530 28532 28533Piping kit for storage tank 46785 46785 46785

Technical dataFRIWA TacoTherm Fresh Mega2 XConnections primary /secondary (IG) [Inch] Rp 1Circulation (AG) [Inch] Rp 1max. T / max. P (TW) [°C/bar] 85 / 9WW output (KW 10° and WW 45°) - inlet flow temperature 75°C [l/min] 60Medium primary /secondary Heater water / Drinking waterHeat exchanger 40 plates / stainless steel 1.4401; copper-solderedDimensionsDimensions W x H x D (incl. insulation) [mm] 470 x 685 x 193

Syst

em p

rodu

cts

Page 50: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

50 I System products

Energy control centre EZ

Price / order number

Product descriptionThe Huch power station is a compact heating station for centralised and efficient energy storage and optimal heat distri-bution. This is the intelligent and future-oriented combination of hygienic drinking water heating (by means of a freshwater station), the storage of regenerative energies (via a solar station) and efficient heating (via highly-efficient pumps). Short and heat-insulated connecting lines minimise the pressure and cooling losses of the heating station. By means of a central control unit, by using high-efficiency pumps, a freshwater station with circulation for drinking water heating and the integ-ration of regenerative solar heating, costs for current and heating energy are saved during operation.

Storage type PS-HZ 800 1050

Price

EZ + Storage tank, with Circulation, 2 heating circuits [€/item] 10700,- 11031,-

EZ + Storage tank, with Circulation, 1 heating circuits [€/item] 9432,- 9582,-

EZ + Storage tank, without Circulation, 2 heating circuits [€/item] 10595,- 10729,-

EZ + Storage tank, without Circulation, 1 heating circuits [€/item] 9150,- 9283,-

Order number

EZ + Storage tank, with Circulation, 2 heating circuits, with Fleece insulation RAL 9006

33090 33094

EZ + Storage tank, with Circulation, 1 heating circuitswith Fleece insulation RAL 9006

33091 33095

EZ + Storage tank, without Circulation, 2 heating circuitswith Fleece insulation RAL 9006

33093 33097

EZ + Storage tank, without Circulation, 1 heating circuitswith Fleece insulation RAL 9006

33092 33096

Note: The power station is available in various designs, with and without circulation as well as with one or two heating circuits with different types of control units (external control or room thermostat control).

Domestic / drinking water By means of an installed fresh water station (FRIWA)

A4

A3

A2

A1

Solar thermal system Buffer storage tank with an extensive area bare-tube heat

exchanger and fitted solar station (max. collector surface 12 m2) for ease in combining with a solar system

Heating circuit groupsAvailable with one or two heating circuit groups (max. output 20 kW/heating circuit). Integration and additional attachment

scope for more heat exchangers (e.g. solid fuel, oil, gas).

Page 51: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 51

Power FRIWA 35 l/min (10 - 45°C)

Primary inlet flow [°C] 50 55 60 65 70 75

Primary return flow [°C] 26 22 20 19 18 17

Drinking water tap volume [l/min] 15 20 24 28 32 35

Drinking water output [KW] 37 49 59 69 77 86

Technical data

Storage tank type PS-HZ 800 1050

Contents [Litres] 800 1050

Diameter without insulation [mm] 790 850

Diameter with insulation [mm] 990 1050

Insulation [mm] 100 100

Height with insulation [mm] 1970 2160

Tilted height [mm] 1990 2165

Heating surface top/bottom [m2] 2,5 2,9

Water contents WT (Litres) bottom [Litres] 15,7 19

max. T/ max. P - Storange tank [°C/bar] 95 / 3 95 / 3

max. T/ max. P - GWT [°C/bar] 110 / 16 110 / 16

Heat exchanger (VL/RL) AG [Inch] G 1 G 1

Loading/unloading connections (A1 to A4) [Inch] Rp 1 1/2 Rp 1 1/2

Electric heating (height A3) [Inch] Rp 1 1/2 Rp 1 1/2

Inspection flange for all storage tanks: not available

Sensor/controller connections for all storage tanks: Sensor clamping strip

Ventilation [Inch] Rp 1 1/4 Rp 1 1/4

Dimensions storange tank

A1 [mm] 148 170

A2 [mm] 718 790

A3, E-HZG [mm] 1173 1295

A4 [mm] 1748 1920

Weight * [kg] 170 200

Dimensions energy control center

Dimensions H x W x D [mm] 1630 x 570 x 365 1630 x 570 x 365

Weight [kg] 60 60

* Weight (kg) = installation weight

Syst

em p

rodu

cts

Page 52: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

52 I System products

Heating pump VARIO S

Product description

Price / order numberType heating pump VARIO S2-E* VARIO S3

Price

Heating pump without storage tank [€/item] 1813,- 2055,-

Heating pump with storage tank EBS-PU 300 [€/item] 3035,- —

Flange kit [€/item] 160,- —

Order number

Heating pump without storage tank 31403 31404

Heating pump with storage tank EBS-PU 300 31418 —

Flange kit 31527 —

* with Electric heating ** with PV-signal

The Huch small-capacity heat pump uses renewable energies in highly efficient manner. It is a cost-effective and ecologically sound solution for detached environmentally-compatible detached and semi-detached hou-ses. The heat pumps come as an all-in system with the EBS-PU 300 as well as individually for subsequent storage tank installation by way of the flange for storage tanks over 200 litres (see Page 24/25). Enjoy the best possible comfort in hot water and heat.

VARIO S2-E with integrated electric heating You need an extra flange set - which is separately available - for assembly. Flange set: Flange adapter, sealing rings, insulation sleeve.

Note: The electric heating connection at the storage tank cannot be used in association with VARIO S. Non-standard solutions possible on request!

Technical dataType heating pump VARIO S2-E VARIO S3

max. heat output 3100 W* 2900 W

max. power input 1750 W* 880 W

Electric heating 1200 W —

Electrical connection ~230 V; 50 Hz ~230 V; 50 Hz

Fusing/protection class 16 A / IPX1 16 A / IPX1

max. water temperature [°C] for all heating pumps: 55°C (anti-legionella protection = 65°C **)

Ambient temperature [°C] von +8 bis +35°C von +8 bis +35°C

Refrigerant / Mass R134a / 450 g R134a / 490 g

max. WP pressure 2,3 MPa 2,3 MPa

COP (EN 255/3) 3,7 3,6

Note for all heating pumps: the figures indicated hold good as A15/W15-W45

Required air throughput [m3] 500 (8 – 35 °C) 700 (8 – 35 °C)

Weight (nett) [kg] 31 32

Condenser length [mm] 420 420

Height x width [mm] 780 x 480 780 x 480

Depth (without Condenser) [mm] 290 290

Depth (mit Condenser) [mm] 710 710

Noise level 52 dB(a) 52 dB(a)

Page 53: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 53

Heating pump VARIO W

Product description

Price / order number

Technical data

Type heating pump VARIO W2

Price [€/item] 1965,-

Order number 31400

The VARIO W is especially designed for assembly involving a tubing set (provided by others) and in no way is it inferior to the VARIO S. It is specially suited for installation into all-in systems at a later date. No storage tank or fittings included in the delivery.

Note: The service water storage tank needs to have a minimum 200-litre capacity and a bare tube heat exchanger (GWT) in excess of 0.9 m² (VARIO W2) or 1.4 m² (VARIO W3).

Type heating pump VARIO W2

max. heat output 1830 W

max. power input 480 W

Electrical connection ~230 V; 50 Hz

Fusing/protection class 16 A / IPX1

max. water temperature [°C] for all heating pumps: 55°C (anti-legionella protection = 60°C)

Ambient temperature [°C] von +8 bis +35°C

Refrigerant / Mass R134a / 400 g

max. WP pressure 2,3 MPa

COP (EN 255/3) 3,5

Note for all heating pumps: the figures indicated hold good a bei A15/W15-W45

Required air throughput [m3] 500 (8 – 35 °C)

Weight (nett) [kg] 30

Height x width [mm] 800 x 500

Depth (without Condenser) [mm] 330

Noise level 52 dB(a)

Syst

em p

rodu

cts

Page 54: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

54 I Combined storage tanks

© iStock

Huch combined storage tankThe SKS combined storage tank series - space-saving solutions for your requirements.Combined storage tanks provide space-saving solutions for both domestic water generation and heating. Integrated stratification guide channels ensure perfect heat management and maximum efficiencies. The SKSE / SKSV combined storage tanks are equipped with a 200 litres inner tank (enamelled or stainless steel) on the basis of the tank-in-tank principle for domestic water heating. The SKSW combined storage tanks have a stainless steel corru-gated tube system (5 m² or 8 m²) for domestic water heating. The SKSP combined buffer storage tanks are suitable for assembly of a domestic water heater (inner tank or stainless steel corrugated tube) at a later date.

Page 55: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 55

High-grade bare-tube heat exchangersThanks to a special heat exchanger design and arrangement a high extraction grade of up to 96% is achieved.

Optimum temperature stratificationStratification guiding channels and baffle plates ensure that temperature swirls in the storage tank are reduced.

Connection stubsOur connection stubs are a standard 50 mm in length. The fleece insulation thus insulates any non-used connections. This cuts radiation losses and an improved energy efficiency is achieved by the storage tank.

Manifold connection scopeOur combined storage tanks have a host of connections. This makes possible an optimum system attachment for the most varied of applications.

Domestic water-suitedHygienically correct domestic water heating thanks to high-grade quality stainless steel.

Flexible positioning of the temperature sensorsSensor clamping strips allow the temperature sensor to be positioned at will. As a result, the Huch storage tanks are suitable for many application fields.

Innovative highly efficient storage tank insulationThe high-grade Polyline© fleece insulation incl. a 100 mm lid and a 50 mm base insulation reduces heat loss by 10-15 % over soft foam.

1

2

3

4

5

6

The SKSE-2G combined storgae tank is shown in the illustration.

1

4

3

2

7

7

5

Quality features

Connection scheme

Schematic diagram – relevant standards and regulations must be observed!

Cold water (KW)

Fireplace with water pocket

Wall-hung heater

Com

bine

d st

orag

e ta

nks

Page 56: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

56 I Combined storage tanks

Combined storage tank overview

SKSE-0

SKSV-0

SKSE-1

SKSV-1

SKSE-2

SKSV-2

SKSE

SKSV

Legend tank identification SKS E-2 851/200Combined storage tank

E = with enamelled internal 200 litres tankV = with stainless steel internal 200 litres tankW = with stainless steel corrugated pipe system 5 m2

W8 = with stainless steel corrugated pipe system 8 m2

P = Buffer storage tank

Number of bare-tube heat exchanger(0, 1 or 2 item)

Water content buffer / drinking water (SKSE / SKSV)or water content buffer (SKSW / SKSP)

with enamelled internal 200 litres tank for drinking water heating

with stainless steel internal 200 litres tank for drinking water heating

Page 57: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 57

SKSP-0

WKS

SKSW-0

SKSP-1

WKS-1G

SKSW-1

SKSP-2

WKS-2G

SKSW-2

SKSP

SKSW

WKS

with stainless steel corrugated pipe system for drinking water heating

with stainless steel corrugated pipe system (5 m²) for drinking water heating

can be additionally retrofitted with a drinking water heater

Com

bine

d st

orag

e ta

nks

Page 58: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

58 I Combined storage tanks

Combined storage tank SKSE/SKSV

Product description» Material: S235JR+N steel, internal uncoated, external primer coat » Compressive strenght: 3 bar» Technical features: two stratified guide channels, Sensor clamping strip, optionally with up to two additional solar heat exchangers (-0, -1, -2), from 800 litres with an electric heating sleeve (Rp 1 ½“)» integrated drinking water heater is available in the following designs: • SKSE: with enamelled internal 200 litres tank • SKSV: with internal 200 litres stainless steel tank» Insulation: 100 mm polyline fleece insulation including base and lid insulation» Accessories: are on the pages 90 to 97

Note: Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water. Planning and setting up the heating system on the basis of the technical guidelines to avoid oxygen-induced corrosion in keeping with VDI and DIN specifications. See Pages 10/11, Installation instructions!

Combined storage tank SKSE/SKSV 401/200 601/200 801/200 1051/200 1301/200PriceSKSE-2 without insulation [€/item] 2313,- 2424,- 2543,- 2880,- 2915,-SKSE-1 without insulation [€/item] 2147,- 2228,- 2335,- 2667,- 2699,-SKSE-0 without insulation [€/item] 1951,- 2015,- 2050,- 2374,- 2379,-SKSV-2 without insulation [€/item] 4644,- 4842,- 4951,- 5301,- 5390,-SKSV-1 without insulation [€/item] 4555,- 4662,- 4734,- 5080,- 5112,-SKSV-0 without insulation [€/item] 4321,- 4366,- 4402,- 4700,- 4742,-Fleece insulation [€/item] 565,- 584,- 616,- 763,- 1021,-Order numberSKSE-2 without insulation 30435 30436 30437 30438 30439SKSE-1 without insulation 30440 30441 30442 30443 30444SKSE-0 without insulation 30445 30446 30447 30448 30449SKSV-2 without insulation 30450 30451 30452 30453 30454SKSV-1 without insulation 30455 30456 30457 30458 30459SKSV-0 without insulation 30460 30461 30462 30463 30464Fleece insulation RAL 9006 28481 28482 28483 28484 28485

Price / order number

1) Special solutions such as the combination of various heat sources also allow for other applications.

Suitable for1:

Heater

Wood burning plant /Wood chip heating

Solar heating plant

Biomass plant /Biogas plantCombined heat and power plant

Heating pump system

Drinking water

Circulation (Z)

Hot water (WW)Cold water (KW)

Sensor clamping strip

VentilationVL / RL solar circuit

Page 59: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 59

* In order to achieve the specified NL number, the boiler out** Standby unit up to A3; continuous output (l/h) = 10 min. Peak consumption x 6 when boiler output > continuous output *** Storage unit loaded between connection A1 and A4; continuous output (l/h) = 10 min. peak tap volume x 6 for boiler output > continuous output**** Weight (kg) = installation weight

Combined storage tank SKSE/SKSV 401/200 601/200 801/200 1051/200 1301/200

Total content [Litres] 600 800 1000 1250 1500

Content (HZG/WW) [Litres] 400/200 600/200 800/200 1050/200 1300/200

Content of standby unit [Litres] 224 227 329 425 506

Energy efficiency class

Heat retaining loss (with insulation) [Watt] 121 134 145 154 168

Diameter without insulation [mm] 700 790 790 900 1000

Diameter with insulation [mm] 900 990 990 1100 1200

Insulation [mm] 100 100 100 100 100

Height with insulation [mm] 1870 1842 2250 2270 2180

Tilted height [mm] 1920 1900 2330 2330 2280

Heating surface top/bottom [m2] 1,3 / 2,0 1,4 / 2,5 2,0 / 3,2 2,1 / 3,2 2,15 / 4,25

NL number* according to DIN 4708 1,8 2,1 2,5 2,8 3,2

max. T/ max. P - TW [°C/bar] 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10

max. T/ max. P - WT-HZG [°C/bar] 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25

max. T/ max. P - Buffer storage tank [°C/bar] 95 / 3 95 / 3 95 / 3 95 / 3 95 / 3

max. D p storage tank / TW-corrugates pipe [bar] 6 6 6 6 6

Cold water / hot water AG (KW/WW) [Inch] G ¾ G ¾ G ¾ G ¾ G ¾

Circulation AG (Z) [Inch] G ¾ G ¾ G ¾ G ¾ G ¾

Heat exchanger all AG (VL/RL) [Inch] G 1 G 1 G 1 G 1 G 1

Loading/unloading connections IG (A1-A4) [Inch] Rp 1 ½ Rp 1 ½ Rp 1 ½ Rp 1 ½ Rp 1 ½

Electric heating IG (E-HZG) / max. immersion depth

[Zoll/mm] - Rp 1 ½ / 475 Rp 1 ½ / 475 Rp 1 ½ / 590 Rp 1 ½ / 650

Sensor/controller connections for all storage tanks: Sensor clamping strip

Inspection flange / Thermometer connections for all storage tanks: not possible

Dimensions

A1 [mm] 246 246 246 288 320

RL 1 (only version -1, -2) [mm] 246 246 246 288 320

A2 [mm] 646 646 786 812 786

VL 1 (only version -1, -2) [mm] 786 816 946 888 1020

RL 2 (only version -2) [mm] 1126 1126 1406 1426 1343

A3 [mm] 1046 1046 1326 1336 1253

A4 [mm] 1496 1466 1866 1858 1720

VL 2 (only version -2) [mm] 1466 1416 1836 1811 1393

E-HZG [mm] - 896 1176 1186 1103

Weight SKSV-0/-1/-2 **** [kg] 160/191/211 174/212/234 194/243/273 250/299/331 268/333/366

Weight SKSE-0/-1/-2 **** [kg] 204/235/255 218/256/278 238/287/317 294/343/375 312/377/410

Technical data

Com

bine

d st

orag

e ta

nks

Page 60: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

60 I Combined storage tanks

Combined storage tank SKSW

Combined storage tank SKSW/SKSW8 601 801 1001 1251 1501PriceSKSW-2 without insulation [€/item] 2347,- 2458,- 2546,- 2920,- 2955,-SKSW-1 without insulation [€/item] 2179,- 2268,- 2362,- 2700,- 2743,-SKSW-0 without insulation [€/item] 1955,- 2019,- 2055,- 2377,- 2420,-SKSW8-0/-1/-2 without insulation [€/item] on requestFleece insulation [€/item] 565,- 584,- 616,- 763,- 1021,-Order numberSKSW-2 without insulation 30416 30417 30419 30421 30422SKSW-1 without insulation 30423 30424 30425 30426 30427SKSW-0 without insulation 30428 30429 30430 30431 30432Fleece insulation RAL 9006 28481 28482 28483 28484 28485

Product description» Material: S235JR+N steel, internal uncoated, external primer coat » Compressive strenght: 3 bar» Technical features: two stratified guide channels, integated drinking water heater as 5 m2 stainless steel corrugated pipe system (8 m² Heating surface on request), Sensor clamping strip, optionally with up to two additional solar heat exchangers (-0, -1, -2), from 800 litres with an electric heating sleeve (Rp 1 ½“)» Insulation: 100 mm polyline fleece insulation including base and lid insulation» Circulation: via Circulation lance, provided by the customer (see at p. 96)» Accessories: are on the pages 90 to 97

Note: Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water. Planning and setting up the heating system on the basis of the technical guidelines to avoid oxygen-induced corrosion in keeping with VDI and DIN specifications. See Pages 10/11, Installation instructions!

Price / order number

1) Special solutions such as the combination of various heat sources also allow for other applications.

Suitable for1:

Heater

Wood burning plant /Wood chip heating

Solar heating plant

Biomass plant /Biogas plant

Combined heat and power plant

Heating pump system

Drinking water

Hot water (WW)

Cold water (KW)

Sensor clamping stripVentilation

VL / RL solar circuit

Page 61: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 61

* In order to achieve the specified NL number, the boiler out** Standby unit up to A3; continuous output (l/h) = 10 min. Peak consumption x 6 when boiler output > continuous output *** Storage unit loaded between connection A1 and A4; continuous output (l/h) = 10 min. peak tap volume x 6 for boiler output > continuous output**** for SKSW circulation via T-piece in WW outflow possible***** Weight (kg) = installation weight

Combined storage tank SKSW/SKSW8 601 801 1001 1251 1501

Content [Litres] 600 800 1000 1250 1500

Content of standby unit [Litres] 224 227 329 425 506

Energy efficiency class

Heat retaining loss (with insulation) [Watt] 121 134 145 154 168

Diameter without insulation [mm] 700 790 790 900 1000

Diameter with insulation [mm] 900 990 990 1100 1200

Insulation [mm] 100 100 100 100 100

Height with insulation [mm] 1850 1822 2230 2250 2160

Tilted height [mm] 1860 1860 2220 2250 2210

Heating surface top/bottom [m2] 1,3 / 2,0 1,4 / 2,5 2,0 / 3,2 2,1 / 3,2 2,15 / 4,25

Heating surface TW corrugate pipe SKSW / SKSW8 [m2] optinally 5 m2 or 8 m2

Water content WT top/bottom [Litres] 8,2 / 12,5 8,8 / 15,7 12,5 / 20,1 13,2 / 20,1 13,5 / 26,7

Water Content TW corrugate pipe SKSW / SKSW8 [Litres] 27 / 43 27 / 43 27 / 43 27 / 43 27 / 43

NL number* according to DIN 4708 2,2 2,5 3,2 3,5 3,8

10-min peak tap volume at standby unit temp.** 52°C [Litres] 125 160 167 181 215

10-min peak tap volume at standby unit temp.** 65°C [Litres] 170 220 258 325 360

10-min peak tap volume of SKSW / SKSW8 at storage tank temp.*** 65°C

[Litres] 230/245 324/340 370/389 403/423 460/480

theoretical continuous output 5 m² for all storage tanks: 1950 l/h heating output 80 kW

theoretical continuous output 8 m² (on request) for all storage tanks: 3100 l/h heating output 126 kW

max. T/ max. P - WT-HZG [°C/bar] 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25

max. T/ max. P - Buffer storage tank [°C/bar] 95 / 3 95 / 3 95 / 3 95 / 3 95 / 3

max. D p storage tank / TW-corrugate pipe [bar] 6 6 6 6 6

Cold wate / hot water AG (KW/WW) [Inch] G 1 G 1 G 1 G 1 G 1

Heat exchanger all AG (VL/RL) [Inch] G 1 G 1 G 1 G 1 G 1

Loading/unloading connections IG (A1-A4) [Inch] Rp 1 ½ Rp 1 ½ Rp 1 ½ Rp 1 ½ Rp 1 ½

Electric heating IG (E-HZG) / max. immersion depth [Zoll/mm] - Rp 1 ½ / 475 Rp 1 ½ / 475 Rp 1 ½ / 590 Rp 1 ½ / 650

Sensor/controller connections for all storage tanks: Sensor clamping strip

Inspection flange / Thermometer connections for all storage tanks: not possible

Dimensions

A1 [mm] 246 246 246 288 320

RL 1 (only version -1, -2) [mm] 246 246 246 288 320

A2 [mm] 646 646 786 812 786

VL 1 (only version -1, -2) [mm] 786 816 946 888 1020

RL 2 (only version -2) [mm] 1126 1126 1406 1426 1343

A3 [mm] 1046 1046 1326 1336 1253

A4 [mm] 1496 1466 1866 1858 1720

VL 2 (only version -2) [mm] 1466 1416 1836 1811 1393

E-HZG [mm] - 896 1176 1186 1103

Weight SKSW-0/-1/-2 ***** [kg] 145/181/201 164/202/224 184/233/263 240/289/321 258/323/356

Technical data

Com

bine

d st

orag

e ta

nks

Page 62: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

62 I Combined storage tanks

Kombi-Buffer storage tank SKSP

Combined buffer storage tank SKSP 601 801 1001 1251 1501PriceSKSP-2 without insulation [€/item] 1479,- 1602,- 1721,- 2059,- 2094,-SKSP-1 without insulation [€/item] 1313,- 1462,- 1496,- 1827,- 1858,-SKSP-0 without insulation [€/item] 1088,- 1172,- 1208,- 1539,- 1628,-Fleece insulation [€/item] 565,- 584,- 616,- 763,- 1021,-Order numberSKSP-2 without insulation 30465 30466 30467 30468 30469SKSP-1 without insulation 30470 30471 30472 30473 30474SKSP-0 without insulation 30475 30476 30477 30478 30479Fleece insulation RAL 9006 28481 28482 28483 28484 28485

Product description» Material: S235JR+N steel, internal uncoated, external primer coat » Compressive strenght: 3 bar» Technical features: two stratified guide channels, Sensor clamping strip, optionally with up to two additional solar heat exchangers (-0, -1, -2), from 800 litres with a electric heating sleeve (Rp 1 ½“)» Insulation: 100 mm polyline fleece insulation including base and lid insulation» Buffer storage tank (SKSP) can be additionally retrofitted with drinking water heater» Accessories: are on the pages 90 to 97

Note: Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water. Planning and setting up the heating system on the basis of the technical guidelines to avoid oxygen-induced corrosion in keeping with VDI and DIN specifica-tions. See Pages 10/11, Installation instructions!

Price / order number

Connection (A4)

Connection (A3)

Electric heating

Connection (A2)

Connection (A1)Return flow (RL1)

Return flow (RL2)

Inlet flow(VL1)

Inlet flow(VL2)

Foot ring

1) Special solutions such as the combination of various heat sources also allow for other applications.

Suitable for1:

Heater

Wood burning plant /Wood chip heating

Solar heating plant

Biomass plant /Biogas plant

Combined heat and power plant

Page 63: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 63

* Weight (kg) = installation weight

Combined buffer storage tank SKSP 601 801 1001 1251 1501

Content [Litres] 600 800 1000 1250 1500

Energy efficiency class

Heat retaining loss (with insulation) [Watt] 121 134 145 154 168

Diameter without insulation [mm] 700 790 790 900 1000

Diameter with insulation [mm] 900 990 990 1100 1200

Insulation [mm] 100 100 100 100 100

Height with insulation [mm] 1850 1822 2230 2250 2160

Tilted height [mm] 1860 1860 2220 2250 2210

Heating surface top/bottom [m2] 1,3 / 2,0 1,4 / 2,5 2,0 / 3,2 2,1 / 3,2 2,15 / 4,25

Water content WT top/bottom [Litres] 8,2 / 12,5 8,8 / 15,7 12,5 / 20,1 13,2 / 20,1 13,5 / 26,7

max. T/ max. P - WT-HZG [°C/bar] 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25

max. T/ max. P - Buffer storage tank [°C/bar] 95 / 3 95 / 3 95 / 3 95 / 3 95 / 3

max. D p storage tank / TW-corrugated pipe [bar] 6 6 6 6 6

Heat exchanger all AG (VL/RL) [Inch] G 1 G 1 G 1 G 1 G 1

Loading/unloading connections IG (A1-A4) [Inch] Rp 1 ½ Rp 1 ½ Rp 1 ½ Rp 1 ½ Rp 1 ½

Electric heating IG (E-HZG) / max. immersion depth [Zoll/mm] - Rp 1 ½ / 475 Rp 1 ½ / 475 Rp 1 ½ / 590 Rp 1 ½ / 650

Sensor/controller connections for all storage tanks: Sensor clamping strip

Inspection flange / Thermometer connections for all storage tanks: not possible

Dimensions

A1 [mm] 246 246 246 288 320

RL 1 (only version -1, -2) [mm] 246 246 246 288 320

A2 [mm] 646 646 786 812 786

VL 1 (only version -1, -2) [mm] 786 816 946 888 1020

RL 2 (only version -2) [mm] 1126 1126 1406 1426 1343

A3 [mm] 1046 1046 1326 1336 1253

A4 [mm] 1496 1466 1866 1858 1720

VL 2 (only version -2) [mm] 1466 1416 1836 1811 1393

E-HZG [mm] - 896 1176 1186 1103

Weight SKSP-0/-1/-2 * [kg] 120/151/171 134/172/194 154/203/233 210/259/291 228/293/326

Technical data

Com

bine

d st

orag

e ta

nks

Page 64: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

64 I Combined storage tanks

Combined storage tank WKS / WKS-G / WKS-2G

» Material: S235JR+N steel, internal uncoated, external primer coat » Compressive strenght: 3 bar» Technical features: integated drinking water heater as 5 m2 stainless steel corrugated pipe system (firmly welded), optionally with up to two additional solar heat exchangers (-0, -1, -2), from 800 litres with a electric heating sleeve (Rp 1 ½“)» Connections: WW/KW as G¾“, buffer storage unit connections as Rp 1 ½“» Insulation: 100 mm polyline fleece insulation including base and lid insulation » Accessories: are on the pages 90 to 97

Note: Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water. Planning and setting up the heating system on the basis of the technical guidelines to avoid oxygen-induced corrosion in keeping with VDI and DIN specifications. See Pages 10/11, Installation instructions!

Type - Combined storage tank WKS 600 800 1000 1250 1500PriceWKS without insulation [€/item] 1921,- 1945,- 1967,- 2327,- 2407,-WKS-G without insulation [€/item] 2086,- 2195,- 2248,- 2612,- 2631,-WKS-2G without insulation [€/item] 2241,- 2352,- 2454,- 2824,- 2846,-Fleece insulation [€/item] 565,- 584,- 616,- 763,- 1021,-Order numberWKS without insulation 36701 36706 36711 36718 36723WKS-G without insulation 35201 35205 35210 35214 35218WKS-2G without insulation 35135 35060 35083 35093 35123Fleece insulation RAL 9006 42266 41259 41260 42268 42269

Product description

Price / order number

1) Special solutions such as the combination of various heat sources also allow for other applications.

Suitable for1:

Heater

Wood burning plant /Wood chip heating

Solar heating plant

Biomass plant /Biogas plant

Combined heat and power plant

Drinking water

Hot water (WW) Cold water (KW)

Sensor clamping strip

Ventilation

VL / RL solar circuit

Page 65: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 65

* In order to achieve the specified NL number, the boiler out** Standby unit up to A3; continuous output (l/h) = 10 min. Peak consumption x 6 when boiler output > continuous output *** Storage unit loaded between connection A1 and A4; continuous output (l/h) = 10 min. peak tap volume x 6 for boiler output > continuous output**** for SKSW circulation via T-piece in WW outflow possible***** Weight (kg) = installation weight

Type - Combined storage tank WKS 600 800 1000 1250 1500

Content [Litres] 600 800 1000 1250 1500

Energy efficiency class

Heat retaining loss (with insulation) [Watt] 121 134 145 154 168

Diameter without insulation [mm] 700 790 790 900 1000

Diameter with insulation [mm] 900 990 990 1100 1200

Insulation [mm] 100 / 100 100 / 100 100 / 100 100 / 100 100 / 100

Height with insulation [mm] 1849 1797 2225 2243 2160

Tilted height [mm] 1920 1900 2300 2310 2260

Heating surface top/bottom [m²] 1,3/2,0 1,4/2,5 2,0/3,2 2,1/3,2 2,15/4,25

Heating surface TW-corrugate pipe WKS [m²] 5 5 5 5 5

Water content WT top/bottom [Litres] 8,2/12,5 8,8/15,7 12,5/20,1 13,2/20,1 13,5/26,7

Water Content TW-corrugate pipe WKS [Litres] 27

NL number* according to DIN 4708 WKS 2,2 2,5 3,2 3,5 3,8

10-min peak tap volume WKS as standby unit temp.** 52°C

[Litres] 125 160 167 181 215

10-min peak tap volume WKS as standby unit temp.** 65°C

[Litres] 170 220 258 325 360

10-min peak tap volume WKS storage tank temp.*** 65°C

[Litres] 230 324 370 403 460

theoretical continuous output 5m² 1950 l/h heating output 80 kW

max. T/ max. P (°C/bar ) WT-HZG [°C / bar] 110° / 16 110° / 16 110° / 16 110° / 16 110° / 16

max. T/ max. P (°C/bar ) Buffer storage tank [°C / bar] 95° / 3 95° / 3 95° / 3 95° / 3 95° / 3

max. D p storage tank / TW-corrugate pipe [bar] 6 6 6 6 6

Cold water / hot water (KW/WW) stainless steel corrugate pipe 28 x 1,5 for Press fitting

Heat exchanger all AG (VL/RL) [Inch] G 1“ G 1“ G 1“ G 1“ G 1“

Loading/unloading connections IG (A1-A4) [Inch] Rp 1 1/2“ Rp 1 1/2“ Rp 1 1/2“ Rp 1 1/2“ Rp 1 1/2“

Electric heating IG (E-HZG) [Inch] - Rp 1 1/2“ Rp 1 1/2“ Rp 1 1/2“ Rp 1 1/2“

immersion depth Electric heating - 475 475 590 640

Sensor/controller connections Sensor clamping strip

Dimensions

A1 [mm] 246 246 246 288 320

RL 1 (only version -1, -2) [mm] 246 246 246 288 320

A2 [mm] 646 646 786 812 786

VL 1 (only version -1, -2) [mm] 786 816 946 888 1020

RL 2 (only version -2) [mm] 1126 1126 1406 1426 1343

A3 [mm] 1046 1046 1326 1336 1253

A4 [mm] 1496 1466 1866 1858 1720

VL 2 (only version -2) [mm] 1466 1416 1836 1811 1393

E-HZG [mm] - 896 1176 1186 1103

Weight WKS /-1/-2 **** [kg] 125/161/181 144/182/202 164/213/233 249/269/289 283/303/323

Technical data

Com

bine

d st

orag

e ta

nks

Page 66: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

66 I Stainless steel storage tanks

© iStock

Page 67: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 67

High-grade bare-tube heat exchangersThanks to a special heat exchanger design and arrangement a high extraction grade of up to 96% is achieved.

Domestic water-suitedHygienically correct domestic water heating thanks to high-grade quality stainless steel.

Innovative highly efficient storage tank insulationThe high-grade Polyline© fleece insulation incl. a 100 mm lid and a 50 mm base insulation reduces heat loss by 10-15 %.

PU rigid foam insulation - 50 mm high-grade polyurethane foam firmly wraps up the vessels in foam. No chimney effect develops and the insulation has excellent insulating properties.

1

2

3

The HSS stainles steel solar storage tank is shown in the illustration.

1

3

2

Quality features

Huch Stainless steel storage tankHigh-grade storage solutionsOur stainless steel storage tanks are designed for the hygienic hot water generation of domestic water and/or heating. Stainless steel storage tanks have long service lives and are practically maintenance-free.

Stai

nles

s st

eel s

tora

ge ta

nks

Page 68: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

68 I Stainless steel storage tanks

Inlet flow (VL2)

Return flow (RL2)Electric heating

Hot water (WW)

Feets

Return flow (RL1)

Inspection flange with optional connection for additional heat sources

(RFL)

Cold water (KW)

Inlet flow (VL1)

Circulation (Z)

Sensor/ controller Connection

Sensor/controller connections

Sensor/controller connections

Stainless steel solar storage tank HSS

Price / order number

Storage type HSS 200 300 400 500 800 1000

Price

Storage tank with insulation [€/item] 3376,- 4187,- 4754,- 4993,- - -

Storage tank without insulation [€/item] - - - - 6148,- 7047,-

Fleece insulation [€/item] - - - - 607,- 723,-

Order number

Storage tank with insulation RAL 9006 36921 36922 36923 36924 - -

Storage tank without insulation - - - - 13332 13060

Fleece insulation RAL 9006 - - - - 36890 35830

Product description» Material: Stainless steel AISI 316L (1.4404)» Compressive strenght: 8 bar» Technical features: two large bare-tube heat exchanger, Inspection flange 120 / 180» Insulation: until 500 litres 50 mm PU rigid foam insulation with Sky-coating, from 800 litres 100 mm polyline-fleece insulation including base and lid insulation » until 2.000 Litres on request» Accessories: are on the pages 90 to 97

Note: Pay attention to the applicable DIN and DVGW specifi-cations when connecting up the domestic water. See Pages 10/11, Installation instructions!

Premium quality

Optimal in price & performance

Suitable for1:

1) Special solutions such as the combination of various heat sources also allow for other applications.

Pellet heating

Condensing power plant

Oil heating plant

Gas plant

Solar heating plant

Drinking water

Heater

Wood burning plant /Wood chip heating

Biomass plant /Biogas plantCombined heat and power plant

Page 69: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 69

Technical data

* In order to achieve the specified NL number, the boiler output must be higher than the specified continuous output.

Storage type HSS 200 300 400 500 800 1000Contents [Litres] 176 269 390 470 709 884Energy efficiency classHeat retaining loss [Watt] 56,7 68,2 72 80,6 134 145Diameter without insulation [mm] 450 500 650 650 790 790Diameter with insulation [mm] 550 600 750 750 990 990Insulation [mm] 50 50 50 50 100 100Height with insulation [mm] 1305 1595 1395 1645 1750 2110Tilted height [mm] 1430 1720 1600 1820 1745 2095Heating surface top/bottom [m²] 0,5/0,9 0,85/1,3 0,9/1,6 1,1/1,95 1,5/2,7 1,9/3Water content WT top/bottom [Litres] 3,5 / 6,4 6 / 9,2 6,4 / 11,3 7,8 / 13,8 10,6 / 19,2 13,5 / 21,3Flow rate WT top/bottom [m³/h] 2 / 2 2 / 2 3 / 3 3 / 3 3 / 3 3 / 3Pressure WT top/bottom [mbar] 20/30 30/40 60/110 80/140 110/190 140/210

NL number top/bottom* according to DIN 4708

1,2 / 3,5 2 / 7,8

3,4 / 12,2 5,2 / 18,1 7,4 / 22 11,2 /2 9,1

Continuous output top/bottom according DIN 4708 (10°/80°/45°)

[l/h] 376 / 650 614 / 900 670 / 1132 802 / 1351 1072 / 1767 1316 / 1940

Continuous output top/bottom according DIN 4708 (10°/80°/45°)

[kW] 15,3 / 26,5 25 / 36,6 27,3 / 46,1 32,7 / 55 43,6 / 71,9 53,6 / 79

max. T/ max. P - TW [°C/bar] 95/8 95/8 95/8 95/8 95/8 95/8max. T/ max. P - HZG [°C/bar] 95/12 95/12 95/12 95/12 95/12 95/12Cold water / hot water (KW/WW) [Inch] 1 IG 1 IG 1 IG 1 IG 1 ½ IG 1 ½ IG Circulation (Z) [Inch] ½ ½ ½ ½ 1 1 Heat exchanger (VL/RL) [Inch] 1 1 1 1 1 1Electric heating [Inch] for all storage tanks: possible via E-HZG connection = 1 ½ IGNominal width of control flange (RFL) 200 - 1000l: 120/180Sensor/controller connections [Inch] for all storage tanks: ½ IGThermometer connections [Inch] for all storage tanks: ½DimensionsKW [mm] 110 120 145 145 170 170RL 1 [mm] 190 230 240 240 275 275VL 1 [mm] 630 790 690 840 870 1020Electric heating [mm] 690 845 745 895 940 1090RL 2 [mm] 740 900 800 950 1010 1160VL 2 [mm] 950 1200 1000 1250 1385 1635WW [mm] top top top top top topWeight [kg] 59 78 89 104 175 204

Stai

nles

s st

eel s

tora

ge ta

nks

Page 70: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

70 I Stainless steel storage tanks

Stainless steel domestic water storage tank HBS

Price / order number

Storage type HBS 150 200 300 400 500 800 1000

Price

Storage tank with insulation [€/item] 2785,- 2979,- 3481,- 4033,- 4268,- - -

Storage tank without insulation [€/item] - - - - - 5248,- 6257,-

Fleece insulation [€/item] - - - - - 607,- 723,-

Order number

Storage tank with insulation RAL 9006 36916 36917 36918 36919 36920 - -

Storage tank without insulation - - - - - 12568 12679

Fleece insulation - - - - - 36890 35830

Product description

Premium quality

Suitable for1:

1) Special solutions such as the combination of various heat sources also allow for other applications.

Pellet heating

Condensing power plant

Oil heating plant

Gas plant

Drinking water

Heater» Material: Stainless steel AISI 316L (1.4404)» Compressive strenght: 8 bar» Technical features: large bare-tube heat exchanger, Inspection flange 120 / 180» Insulation: until 500 litres 50 mm PU rigid foam insulation with Sky-coating, from 800 litres 100 mm polyline-fleece insulation including base and lid insulation » until 2.000 Litres on request» Accessories: are on the pages 90 to 97

Note: Pay attention to the applicable DIN and DVGW specifi-cations when connecting up the domestic water. See Pages 10/11, Installation instructions!

Optimal in price & performance

Wood burning plant /Wood chip heating

Biomass plant /Biogas plantCombined heat and power plant

Electric heating

Hot water (WW)

Feets

Return flow (RL1)

Inspection flange with optional connection for additional heat sources

(RFL)Cold water (KW)

Inlet flow (VL1)

Circulation (Z)

Sensor/ controller Connection

Sensor/controller connections

Page 71: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 71

Technical data

* In order to achieve the specified NL number, the boiler output must be higher than the specified continuous output.

Storage type HBS 150 200 300 400 500 800 1000

Contents [Litres] 140 181 278 399 481 723 902

Energy efficiency class

Heat retaining loss [Watt] 49,7 56,7 68,2 72,0 80,6 134 145

Diameter without insulation [mm] 450 450 500 650 650 790 790

Diameter with insulation [mm] 550 550 600 750 750 990 990

Insulation [mm] 50 50 50 50 50 100 100

Height with insulation [mm] 1050 1300 1590 1390 1640 1745 2090

Tilted height [mm] 1210 1440 1730 1610 1835 1745 2095

Heating surface [m²] 0,85 0,9 1,3 1,6 1,95 2,7 3,0

Water content WT [Litres] 6,0 6,4 9,2 11,3 13,8 19,2 21,3

Flow rate WT [m³/h] 2 2 2 3 3 3 3

Pressure loss WT [mbar] 30 30 40 110 140 190 210

NL number DIN 4708 2,2 3,5 7,8 12,2 18,1 22 29,1

Continuous outputDIN 4708 (10°/80°/45°)

[l/h](kW)

487 (19,8) 650 (26,5)

900(36,6)

1132(46,1)

1351(55)

1767(71,9)

1940(79)

max. T/ max. P - TW [°C/bar] 95/8 95/8 95/8 95/8 95/8 95/8 95/8

max. T/ max. P - HZG [°C/bar] 95/12 95/12 95/12 95/12 95/12 95/12 95/12

Cold water / hot water IG(KW/WW)

[Inch] 1 1 1 1 1 1½ 1½

Circulation (Z) [Inch] ½ ½ ½ ½ ½ 1 1

Heat exchanger IG (VL/RL) [Inch] 1 1 1 1 1 1 1

Electric heating [Inch] for all storage tanks: 1 ½ IG

Nominal width of control flange (RFL) 150 - 1000l: 120/180

Sensor/controller connections [Inch] for all storage tanks: ½ IG

Thermometer connections [Inch] for all storage tanks: ½ IG

Dimensions

KW [mm] 110 110 120 145 145 170 170

RL [mm] 190 190 230 240 240 275 275

VL [mm] 530 630 790 690 840 870 1020

Electric heating [mm] 560 690 845 745 895 940 1090

WW [mm] oben oben oben oben oben oben oben

Weight [kg] 46 54 70 80 93 160 185

Stai

nles

s st

eel s

tora

ge ta

nks

Page 72: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

72 I Stainless steel storage tanks

Optimal in price & performance

Stainless steel buffer storage tank HPS

Price / order number

Storage type HPS 150 200 300 400 500 800 1000

Price

Storage tank with insulation [€/item] 2416,- 2740,- 2984,- 3393,- 3656,- - -

Storage tank without insulation [€/item] - - - - - 4592,- 5338,-

Fleece insulation [€/item] - - - - - 607,- 723,-

Order number

Storage tank with insulation RAL 9006 36903 36904 36905 36906 36907 - -

Storage tank without insulation - - - - - 12438 12567

Fleece insulation RAL 9006 - - - - - 36915 36589

Product description

Premium quality

Suitable for1:

1) Special solutions such as the combination of various heat sources also allow for other applications.

Drinking water

Heater» Material: Stainless steel AISI 316L (1.4404)» Compressive strenght: 8 bar» Technical features: Inspection flange» Insulation: until 500 litres 50 mm PU rigid foam insulation with Sky-coating, from 800 litres 100 mm polyline-fleece insulation including base and lid insulation » until 2.000 Litres on request» Accessories: are on the pages 90 to 97

Note: Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water. See Pages 10/11, Installation instructions! Direct heating system

Wood burning plant /Wood chip heating

Biomass plant /Biogas plantCombined heat and power plant

Electric heating

Hot water (WW)

Feets

Inspection flange with optional connection for additional heat sources

(RFL)Cold water (KW)

Circulation (Z)

Sensor/ controller Connection

Sensor/controller connections

Page 73: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 73

Technical data

Storage type HPS 150 200 300 400 500 800 1000

Contents [Litres] 148 190 290 399 500 750 932

Energy efficiency class

Heat retaining loss [Watt] 49,7 56,7 68,2 72 80,6 134 145

Diameter without insulation [mm] 450 450 500 650 650 790 790

Diameter with insulation [mm] 550 550 600 750 750 990 990

Insulation [mm] 50 50 50 50 50 100 100

Height with insulation [mm] 1050 1305 1595 1410 1645 1750 2110

Tilted height [mm] 1200 1430 1720 1610 1820 1745 2095

max. T/ max. P - TW [°C/bar] 95/8 95/8 95/8 95/8 95/8 95/8 95/8

Cold water / hot water (KW/WW) [Inch] 1 1 1 1 1 1 ½ 1 ½

Circulation (Z) [Inch] ½ ½ ½ ½ ½ 1 1

Electric heating [Inch] 1 ½ 1 ½ 1 ½ 1 ½ 1 ½ 1 ½ 1 ½

Nominal width of control flange (RFL)

120 /180

120 /180

120 /180

120 /180

120 /180

120 /180

120 /180

Sensor/controller connections

[Inch] ½ ½ ½ ½ ½ ½ ½

Thermometer connections IG (F1-F3)

[Inch] ½ ½ ½ ½ ½ ½ ½

Dimensions

KW [mm] 110 110 120 145 145 170 170

Z [mm] 730 840 1050 900 1095 1200 1400

Electric heating [mm] 560 690 845 745 895 940 1090

WW [mm] top top top top top top top

Weight [kg] 38 45 57 64 74 133 155

Stai

nles

s st

eel s

tora

ge ta

nks

Page 74: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

74 I other products

© panthermedia.net / Jan Mika

Page 75: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 75

Quality features

Other Huch vesselsFor the most varied of applicationsPressurized-water boilers, compressed air tanks, filter boilers and expansion tanks for open-type heating systems round off our extensive product range.

Domestic water-suitedThe pressurized-water and filter boilers are hot-dip galvanized in compliance with domestic water considerations on the basis of DIN EN 1461

Qualified manufacturingDWK - manufactured as per European RL 2014/68/EU (pressure equipment) and AD 2000. DLB - manufactured as per European RL 2014/29/EU (non-complex pressure equipment, EN 268 1)

Corrosion protectionThe compressed air and expansion tanks are available in various corrosion-protection types - galvanized or with a rust protection primer.

1

2

3

Not found the right product up to now?The following products are available at your request:

Buffer storage tank from 200 to 25.000 Litres

Cold water buffer storage tank from 300 to 25.000 Litres

enamelled storage tanks to 5.000 Litres

Mobile mixed tank

Baking oven tank

Tanks for combined heat & power plants

Pressure tanks for braking systems

Tanks for compressors

Oil collecting vessels

Tanks for railway engineering

... and much more!

Our calculation aid for custom-made storage tanks and an extract from the dimensions chart is on hand from Page 84. Here you can get an idea of the dimensions. All attachment and mounting parts as well as the enquiry form can be found on the pages that follow.

NEW

NEW

NEW

othe

r pro

duct

s

Page 76: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

76 I other products

Vertical pressurised water tank DWK

Product description

Explanation of the illustration (vertical)1 Hand hole or Manhole closures max. 45° with reference to the tank axis2 Hand hole closure only for tanks with a nominal capacity of 1000 litres3 Bottom according to DIN 280114 Connection for pressure controller5 Connections for water level gauge6 Connection for pump7 Connection for drainage and/or water mains or supply line8 Connection for water mains and/or supply line9 Connection for the exhaust system10 Connection for the ventilation system11 Auxiliary connection

» Manufactured according to RL 2014 / 68 / EU, AD 2000 leaflets and DIN 4810» Produced with pressure rates of 4, 5 or 10 bar

Price / order number

Technical data

Tank type DWK 150 300 500 750 1000 1500 2000 3000

Price

4 bar [€/item] 554,- 689,- 875,- 1375,- 1711,- 3735,- 4827,- 5751,-

6 bar [€/item] 569,- 736,- 930,- 1455,- 1783,- 4265,- 5260,- 6464,-

10 bar [€/item] 1002,- 1295,- 1576,- 2022,- 2625,- 5102,- 5535,- 7305,-

Order number

4 bar 23536 23537 23538 23539 23540 23542 23543 23546

6 bar 00431 00121 00464 00467 00469 01436 00574 01434

10 bar 00116 00463 00466 00468 00470 00998 01433 01435

Tank type DWK 150 300 500 750 1000 1500 2000 3000

Contents [Litres] 150 300 500 750 1000 1500 2000 3000

Diameter D1 [mm] 450 550 650 800 800 1000 1100 1150

Coating length +25 H1 [mm] 790 1100 1310 1250 1750 1560 1770 2500

Tank height H2 [mm] 1055 1405 1655 1655 2165 2060 2315 3085

Total height H3 [mm] 1275 1625 1875 1885 2385 2280 2535 3305

Connection D2 [Inch] Rp 2 Rp 2 Rp 2 Rp 2 Rp 2 Rp 3 Rp 3 Rp 3

Inpection opening

Piece 1 1 1 1 2 1 1 1

Hand hole 100 x 150 100 x 150 100 x 150 100 x 150 100 x 150 — — —

Manhole — — — — — 320 x 420 320 x 420 320 x 420

Weight at permissible compressive strenght

4 bar 40 62 100 143 178 350 465 514

6 bar 40 62 100 143 178 350 465 514

10 bar 50 89 138 185 230 383 490 649

Page 77: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 77

Symbolic illustation!

Pump console

Horizontal pressurised water tank DWK

Explanation of the illustration (vertical)1 Hand hole2 Bottom according to DIN 280113 Connection for pressure controller4 Connection for manometer5 Connections for water level gauge6 Connection for pump inlet pipe7 Connection for water mains and/or power supply

Note: The domestic water ordinance stipulates that water must not be corrosive. A measure for revealing this is the pH-value and the calcite dissolution capacity. The latter involves examining the extent to which lime from the water can be deposited in the pipes or whe-ther water can corrode metallic pipes and thus enable metals (e.g. copper, zinc) to get into the domestic water.As a consequence, de-scaling or neutralisation units for treating the domestic water may be needed (recommended amongst others pH > 7.5; calcite dissolution capacity < 5.0 mg/l) to stop, for instance, pitting as well as pitting and surface corrosion.

» Manufactured according to RL 2014 / 68 / EU, AD 2000 leaflets & DIN 4810» Produced with pressure rates of 4 and 6 bar» The design and arrangement of the connections are based on the requirements of renowned pump manufacturers and their drawings» The illustration shows the basic types of the wide range of products of horizontal DWKs» Specific drawings of each pump manufacturer on request» Specific drawings of the pump manufacturer (e.g. ORPU / OSNA / LOEWE) on demand

Product description

Price

Tank type DWK 60 80 100 100 150 200 250 300

Contents [Litres] 60 80 100 100 150 200 250 300

D [mm] 350 350 350 400 450 500 550 550

L1 [mm] 765 960 1160 850 1070 1030 1145 1350

L2 [mm] 575 770 970 670 810 800 895 1070

Weight [kg] 28 33 37 37 44 54 62 68

Tank type DWK 60 80 100 100 150 200 250 300

Price Ø=350 Ø=400

4 bar [€/item] 572,- 587,- 592,- 608,- 630,- 680,- 757,- 796,-

6 bar [€/item] 585,- 602,- 615,- 626,- 646,- 738,- 814,- 934,-

Order number on demand!

Technical data

othe

r pro

duct

s

Page 78: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

78 I other products

Compressed air tank DLB, vertical design

Product description

Price

Tank Type DLB 40 60 90 150 250 350 500 750 1000Contents [Litres] 40 60 90 150 250 350 500 750 1000Diameter D [mm] 300 300 350 400 500 550 600 750 800Height without feet L [mm] 674 924 990 1310 1400 1610 1780 1880 2160Feet height F [mm] 200 200 200 200 200 200 200 180 180Total height H [mm] 824 1074 1140 1460 1600 1810 1980 2060 2310Coating length M [mm] 500 750 800 1110 1160 1350 1500 1500 1750N [mm] 100 300 300 560 540 530 520 490 480O [mm] 450 700 750 1010 990 980 1310 1280 1270

X [mm] — — — 250 250 250 250 250 250Sleeves A1 RP [Inch] 1 1 1 1 1 1 1 1 1A2 RP [Inch] — — — 1 1 1 1 1 1A3 RP [Inch] ¼ ¼ ¼ ½ ½ ½ ½ ½ ½A4 RP [Inch] ½ ½ ½ 1 1 1 1 1 1A5 RP [Inch] ½ ½ ½ ½ ½ ½ ½ 1 ½ 1 ½HLV [Stk] — — — 1 1 1 1 1 2Weight 11 bar [kg] 29 35 50 60 90 130 145 220 300Weight 16 bar [kg] 34 42 60 75 110 140 165 270 330

Tank Type DLB 40 60 90 150 250 350 500 750 1000Price11 bar - prime coated [€/item] 431,- 524,- 572,- 811,- 888,- 1090,- 1188,- 1800,- 1927,-11 bar - zinc-plated [€/item] 530,- 629,- 668,- 953,- 1129,- 1383,- 1564,- 2303,- 2420,-16 bar - prime coated [€/item] 524,- 621,- 784,- 991,- 1048,- 1243,- 1383,- 1801,- 2722,-16 bar - zinc-plated [€/item] 638,- 720,- 987,- 1217,- 1314,- 1509,- 1830,- 2347,- 3183,-Order number on demand!

» The compressed air tanks up to 750 litres, 11 bar are manufactured according to Directive 2014 / 29 / EU and EN 286 - 1, and from 750 litres, 16 bar according to Pressure Equipment Directive 2014 / 68 / EU and the AD 2000 leaflets.» Permissible operating temperature: -10 - 50°C / from 750 litres 16 bar 0 - 50°C» Connections: Sleeves according to DIN 2986, threads according to DIN 2999» Inspection opening: HLV hand hole closure 100 x 150 mm» Corrosion protection: outside primed / inside uncoated; inside and outside hot-dip galvanised» Compressed air tank with a capacity of more than 1000 litres on request

Technical data

Page 79: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 79

Compressed air tank DLB, horizontal design

Product description

Price

» The compressed air tanks up to 750 litres, 11 bar are manufactured according to Directive 2014 / 29 / EU and EN 286-1, and from 750 litres, 16 bar according to Pressure Equipment Directive 2014 / 68 / EU and the AD 2000 leaflets.» Connections: Sleeves according to DIN 2986, threads according to DIN 2999

» Permissible operating temperature: -10 - 50°C» Inspection opening: HLV hand hole closure 100 x 150 mm» Corrosion protection: outside primed in grey / inside uncoated; inside and outside hot-dip galvanised» Compressed air tank with a capacity of more than 1000 litres on request

Technical data

Tank Type DLB 40 60 90 150 250 350 500 750 1000Price11 bar - prime coated [€/item] 431,- 524,- 572,- 896,- 926,- 1090,- 1188,- 1607,- 1927,-11 bar - zinc-plated [€/item] 530,- 629,- 668,- 1058,- 1164,- 1383,- 1564,- 2067,- 2346,-16 bar - prime coated [€/item] 524,- 621,- 711,- 991,- 1048,- 1260,- 1383,- 1801,- 2722,-16 bar - zinc-plated [€/item] 664,- 720,- 851,- 1217,- 1314,- 1616,- 1830,- 2303,- 3183,-Order number on demand!

Tank Type DLB 40 60 90 150 250 350 500 750 1000Contents [Litres] 40 60 90 150 250 350 500 750 1000Diameter D [mm] 300 300 350 400 500 550 600 750 800Total length L [mm] 755 924 990 1310 1400 1610 1780 1860 2160Feet height F [mm] 70 70 70 70 70 70 70 100 100Total height H [mm] 370 370 420 470 570 620 670 850 900Coating length M [mm] 585 750 800 1110 1160 1350 1500 1500 1750O [mm] — — 110 130 175 200 200 200 200P [mm] 70 140 150 250 245 340 415 415 350Q [mm] 400 500 500 670 670 670 670 670 800T [mm] 45 45 45 45 45 45 45 45 50Sleeves A1 RP [Inch] ¼ ¼ ¼ ¼ ½ ½ ½ ½ ½A2 RP [Inch] ½ ½ ½ ½ ½ ½ ½ ½ ½A3 RP [Inch] — — ¼ ¼ ½ ½ ½ ½ ½A4 RP [Inch] ½ ½ ½ 1 1 1 1 1 1A5 RP [Inch] — — 3/8 3/8 3/8 3/8 3/8 3/8 3/8A6 RP [Inch] 1 1 1½ 1 1 1 1 1 1A7 RP [Inch] ¼ ¼ ¼ ¼ ½ ½ ½ ½ ½HLV [Stk] — — — 1 1 1 1 1 2Weight 11 bar [kg] 29 35 50 60 90 130 145 220 300Weight 16 bar [kg] 34 42 60 75 110 140 160 270 330

only at 1.000 litres only at 1.000 litres

Connection Rp 1 ½" at galvanised version (both sides)

fishplateat 60 litres the drill-hole is Ø11 mmup to 90 litres long hole 20 x Ø10 mm

othe

r pro

duct

s

Page 80: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

80 I other products

Expansion vessel AG

Product description

Technical data

» Expansion vessels according to DIN 4807 for open heating systems» can be used in horizontal and vertical positionThe following corrosion protection variants are available:» coated with corrosion protection primer on untreated surface» hot-dip galvanised

Price on request!

* For zinc-plated expansion vessels a weight increase of 7% must be considered.Note: General tolerances are applicable to measures of length: DIN 7168-m, for sheet size tolerances see DIN 1541

Behältertyp AG 30 50 75 100 125 150 200 250 300 400 500 600 800 1000

Contents [Litres] 30 50 75 100 125 150 200 250 300 400 500 600 800 1000

D1 [mm] 300 350 400 400 500 500 500 500 600 650 700 700 800 800

D2 [Inch] Rp 1 Rp 1 Rp 1¼ Rp 1¼ Rp 1¼ Rp 1¼ Rp 1½ Rp 1½ Rp 1½ Rp 2 Rp 2 Rp 2½ Rp 2½ Rp 2½

L1 [mm] 500 580 670 870 700 850 1110 1350 1180 1310 1420 1660 1700 2125

S [mm] 2 2 2 2 2 3 3 3 3 3 4 4 5 5

prime coated

01439 01035 01024 01021 01826 00252 02277 17410 15215 01027 14658 14667 10719 13572

zinc-plated

01442 01096 01009 01095 01824 02243 02276 03969 14451 02245 12605 19802 05404 18758

Order number

Page 81: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 81

Filter boiler FK

Product description

Technical data

Operating media: WaterOperating temperature: 0-50°CSleeves: DIN 2986 - Rp thread DIN 2999Corrosion protection: inside and outside hot-dip galvanised conform to drinking water DIN EN 1461

Behälter Typ FK 240 350 500 750 1000

Contents [Litres] 240 350 500 750 1000

Diameter D [mm] 450 550 650 800 800

Total height A [mm] 1800 1800 1800 1800 2385

Tank height B [mm] 1600 1600 1600 1600 2165

Coating length C [mm] 1400 1360 1300 1250 1750

Add. label holder E [mm] 590 570 540 515 765

Type plate F [mm] 810 790 760 735 985

G [mm] 45 45 45 45 50

Height of bottom flange H [mm] 150 175 200 200 250

I [mm] 55 55 55 55 60

J [mm] 200 200 200 200 200

Height of top flange K [mm] 150 175 200 200 250

L [mm] 45 45 45 45 50

M [mm] 18 18 20 20 22

Weight 6 bar [kg] 101 129 180 242 322

Price on request!

othe

r pro

duct

s

Page 82: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

82 I Calculation support regarding custom-made storage tanks

Flange nozzlesFor connecting the continuative tubing. Number and position of the flange nozzles can be selected at will.

Tube bendEnlarges optimum height utilization of the storage tank.

HandholeInspection openings for pressure equipment (small-size vessel).

ManholeInspection openings for pressure equipment (large-size vessel).

Inspection flange with blind flange and sealEnables a fin-tubed heat exchange or a flange electric heater to be retrofitted.

Blind flange with connection sleeve G 1 ½" and sealEnables a screw-plug electric heater to be retrofitted.

Connection sleeveFor the purpose of attaching measuring equipment such as thermometers, pressure gauges.

» Fitting & Components

Custom-made storage tanksCustomization down to the last detail

Custom-made storage tanks and vessels are an indispensable addition to our range of products. We would be more than happy to assemble the tank that you require based on your individual particulars and requirements. Just send an enquiry to us.

Features Up to a 2.400 mm diameter

Buffer storage tanks, cold water buffer sto-rage tanks and stainless steel storage tanks up to a 25.000 litre capacity (3 / 6 bar)

Enamelled domestic water and buffer storage tanks up to 5.000 litres and a 1.500 mm diameter

Operating pressure up to 16 bar (conditional upon capacity)

Operating temperature: Storage tank: 0°C - 95°C Heat exchanger: 0°C - 160°C (25 bar)

High-grade S235JR+N quality steel

Various heat and low-temperature insulations available

Various feet design structures

Stand/foot ring:

» Buffer storage tanks up to Ø 1.600 mm and a max. 5000 litres » Enamelled storage tanks up to Ø 1.100 mm and a max. 2.000 litres

Feets:

» Buffer storage tanks above Ø 1.600 mm and upwards of 5000 litres » Enamelled storage tanks above Ø 1.100 mm and upwards of 2.000 litres » All cold water buffer storage tanks (on account of the air circulation)

TÜV-tested on request

NEW

NEW

NEW

Page 83: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 83

Stratified guide channelsEnables the flow within the vessel

to be specifically stratified.

Layer perforation plateMakes possible stratification

inside the vessel.

Nozzle tubesDirect the main flow through without

generating any turbulence in the vessel. Made of steel and stainless steel.

Hoisting eyeThey allow vessels to be

transferred and positioned using crane handling equipment.

Bare-tube heat exchangerUsing an external heat source (e.g. solar thermal system) to

heat the storage tank water.

Threaded nozzleFor attaching continuative

tubing with a threaded adapter.

Sensor clamping stripFor variable positioning of

the temperature sensor.

Cust

om-m

ade

tank

s

Page 84: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

84 I Calculation support regarding custom-made storage tanks

Storage tank diameter Ø 400 mm

55 400 600 25 27

80 400 800 30 32

105 400 1000 35 37

130 400 1200 40 42

155 400 1400 45 47

180 400 1600 50 52

Storage tank diameter Ø 450 mm

70 450 600 29 31

100 450 800 34 36

130 450 1000 39 41

160 450 1200 44 46

190 450 1400 49 51

225 450 1600 54 56

Storage tank diameter Ø 500 mm

125 500 800 39 42

145 500 1000 45 48

205 500 1200 51 54

245 500 1400 57 60

285 500 1600 63 66

325 500 1800 69 72

Storage tank diameter Ø 550 mm

180 550 950 46 49

225 550 1150 53 56

270 550 1350 60 63

315 550 1550 67 70

360 550 1750 74 77

405 550 1950 81 84

Storage tank diameter Ø 600 mm

265 600 1150 60 64

320 600 1350 68 72

375 600 1550 76 80

430 600 1750 84 88

485 600 1950 92 96

540 600 2150 100 105

Contents [Litres]

Ø [mm]

Height [mm]

Weight [kg]

Weight [kg]

3 bar (95°C) 6 bar (95°C)

Contents [Litres]

Ø [mm]

Height [mm]

Weight [kg]

Weight [kg]

3 bar (95°C) 6 bar (95°C)

Storage tank diameter Ø 650 mm

345 650 1250 68 89

410 650 1450 77 99

475 650 1650 86 109

540 650 1850 95 119

605 650 2050 104 129

670 650 2250 113 139

715 650 2380 119 147

Storage tank diameter Ø 700 mm

400 700 1250 79 99

475 700 1450 88 110

550 700 1650 97 121

625 700 1850 106 132

700 700 2050 115 143

775 700 2250 124 154

835 700 2400 131 162

Storage tank diameter Ø 750 mm

490 750 1350 89 114

580 750 1550 99 127

670 750 1750 109 139

760 750 1950 119 141

850 750 2150 129 153

940 750 2350 139 165

975 750 2440 145 172

Storage tank diameter Ø 790 mm

550 790 1350 94 119

645 790 1550 105 131

740 790 1750 116 143

835 790 1950 127 155

930 790 2150 138 167

1025 790 2350 149 179

1075 790 2450 155 185

Storage tank diameter Ø 800 mm

565 800 1350 95 120

665 800 1550 107 133

Enquiry for custom-made storage tanks

Hot water storage tank (3/6 bar) & Cold water storage tank (6 bar)» 100 mm Polyline© fleece insulation for hot water storage tanks» 25 mm "Elastomer" insulation for cold water storage tanks» Other insulating variants possible on request » Vessel on stand ring or bases » Optionally in 3 / 6 / 10 & 16 bar (conditional on capacity)

» Enamelling possible up to 5.000 litres and Ø 1.500 mm» External coating possible as per AGI Worksheet Q151 for cold storage tanks for an extra charge (up to 5000 litres)We would be happy to provide you with an individual supply offer for other pressure levels and sizes up to 25.000 litres. Do use our enquiry form for this.

Calculation support regarding custom-made storage tanks

No stock items! Produced to customer requirements!

Excerpt from our size chartBasic tank for buffer-, drinking water and cold water storage tanks (KWP)

Page 85: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 85

Contents [Litres]

Ø [mm]

Height [mm]

Weight [kg]

Weight [kg]

3 bar (95°C) 6 bar (95°C)

Contents [Litres]

Ø [mm]

Height [mm]

Weight [kg]

Weight [kg]

3 bar (95°C) 6 bar (95°C)

765 800 1750 119 146

865 800 1950 131 159

965 800 2150 143 162

1065 800 2350 155 185

1110 800 2400 161 192

Storage tank diameter Ø 850 mm

635 850 1350 102 131

745 850 1550 115 145

855 850 1750 128 159

965 850 1950 141 173

1075 850 2150 154 187

1185 850 2350 167 201

1260 850 2470 174 208

Storage tank diameter Ø 900 mm

770 900 1450 118 188

900 900 1650 130 207

1020 900 1850 142 226

1150 900 2050 154 243

1275 900 2250 166 262

1410 900 2470 178 281

Storage tank diameter Ø 950 mm

850 950 1450 128 200

1000 950 1650 140 219

1130 950 1850 152 238

1270 950 2050 164 257

1410 950 2250 176 276

1550 950 2450 184 295

1600 950 2500 187 300

Storage tank diameter Ø 1000 mm

940 1000 1450 166 213

1095 1000 1650 171 233

1250 1000 1850 186 253

1410 1000 2050 201 273

1560 1000 2250 216 293

1720 1000 2450 231 313

1800 1000 2540 238 323

Storage tank diameter Ø 1100 mm

1300 1100 1650 204 264

1500 1100 1850 221 286

1700 1100 2050 238 308

1900 1100 2250 255 330

2100 1100 2450 272 352

2150 1100 2540 281 363

Storage tank diameter Ø 1150 mm

1430 1150 1650 214 302

1640 1150 1850 232 326

1850 1150 2050 250 350

2050 1150 2250 258 374

2250 1150 2450 276 398

2400 1150 2580 290 416

Storage tank diameter Ø 1200 mm

1800 1200 1850 251 353

2000 1200 2050 270 378

2250 1200 2250 289 403

2450 1200 2450 308 428

2600 1200 2610 323 446

3000 1200 2950 357 489

Storage tank diameter Ø 1250 mm

2150 1250 2050 277 389

2400 1250 2250 297 415

2650 1250 2450 317 441

2870 1250 2630 337 467

3150 1250 2850 357 493

3400 1250 3050 377 519

3600 1250 3250 397 545

Storage tank diameter Ø 1300 mm

2500 1300 2200 335 405

3100 1300 2650 365 465

3800 1300 3200 415 565

4500 1300 3700 465 630

5150 1300 4200 515 700

5750 1300 4650 555 760

Storage tank diameter Ø 1400 mm

2900 1400 2200 450 625

3650 1400 2700 500 715

4400 1400 3200 550 800

5200 1400 3700 605 890

6000 1400 4200 660 975

6700 1400 4700 710 1065

Storage tank diameter Ø 1500 mm

3300 1500 2200 515 730

4200 1500 2700 570 825

5100 1500 3200 625 920

6000 1500 3700 680 1015

6900 1500 4200 735 1110

7800 1500 4700 790 1205

Storage tank diameter Ø 1600 mm

4000 1600 2300 610 810

5000 1600 2800 665 910

6000 1600 3300 765 1010

7000 1600 3800 850 1110

8000 1600 4300 930 1210

9000 1600 4700 1010 1310

10000 1600 5300 1100 1410

Cust

om-m

ade

tank

s

Page 86: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

86 I Calculation support regarding custom-made storage tanks

Accessories & components for custom-made storage tanks

Size

Flange nozzles (PN 6 / PN 16)DIN 2631 / EN1092-1 Lenght: ~ 140 mm

DN 15

DN 20

DN 25

DN 32

DN 40

DN 50

DN 65

DN 80

DN 100

DN 125

DN 150

DN 200

DN 250

DN 300

Size

Tube bend with flange nozzles (PN 6 / PN 16)DIN 2633 / EN1092-1

DN 15

DN 20

DN 25

DN 32

DN 40

DN 50

DN 65

DN 80

DN 100

DN 125

DN 150

DN 200

DN 250

DN 300

Size

Connection sleeve(for KWP / Buffer)DIN 2986

1/2 Zoll

3/4 Zoll

1 Zoll

1 1/4 Zoll

1 1/2 Zoll

2 Zoll

Size

Branch sleevesLength: 120 mm

1/2 Zoll

3/4 Zoll

1 Zoll

1 1/4 Zoll

1 1/2 Zoll

2 Zoll

Size

Hoisting eye (for transport)

65 x 60 x 6 mm

Size

Layer perforation plate ø 550 mm

ø 600 mm

ø 650 mm

ø 750 mm

ø 800 mm

ø 1000 mm

ø 1100 mm

ø 1300 mm

ø 1400 mm

ø 1600 mm

Size

Stratification guiding channels

400 mm

500 mm

600 mm

720 mm

820 mm

920 mm

1020 mm

Size

Bare-tube heat exchangerincluding optional connectionsUp to 2000 litres, an internal heating coil is available; from 2500 litres we recommend using an external heat ex-changer for more efficiency

2,5 m² ø = 540

from 500 l

2,5 m² ø = 600

from 880 l

3,2 m² ø = 600ab 800 l

4,25 m² ø = 800

from 1500 l

Size

Sensor clamping strips 500 mm

800 mm

Size

Stainless steel nozzle tubes up to 1000 mm (more sizes on request)

DN 100

DN 125

DN 150

DN 200

DN 250

DN 300

Size

Steel 1.0038 nozzle tubes up to 1000 mm (more sizes on request)

DN 65

DN 80

DN 100

DN 125

DN 150

DN 200

DN 250

DN 300

Size

Inspection flange with blind flange incl. seal

DN 200 (DIN 4805)

DN 200

DN 300 PN 6 (EN1092)

DN 400 PN6 (EN1092)

DN 500 PN6 (EN1092)

Size

Blind flange with connectionsleeve G1 ½" incl. seal

DN 200 (DIN 4805)

Size

Manhole 420 x 320 mm

Size

Hand hole 100 x 150 mm

Size

Impact plate(Deflector plate)

60 x 60 x 3 mm

More accessories and components on request!

Page 87: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 87

Copy, complete and fax the form. Drawing of Connections

The General Terms and Conditions for Sale and Delivery of Huch GmbH Behälterbau as well as the agreements acknowledged with order acceptance shall apply to all transactions. Subject to any kind of changes and errors. In order to maintain warranty, only original parts may be used as replacement parts such as seals etc.

rear360°/0°

180°

90°right

270°left

Send the completed enquiry form by fax (0049 - 33920 - 672 77) or by e-mail ([email protected]) to our quotation processing department and you will promptly receive an offer for your desired storage unit.

Description Size Amount

Insulation:

Others:

Date: Signature:

Buffer storage tank Cold water storage tank Drinking water storage tank Others

Contents Litres Compressive strenght bar Connections Item (see drawing) Operating temperature °C

Diameter mm max. Height mm Various feet design: Foot ring oder 3 Feets

Company:

Adress:

Contact person:

Telephon:

E-mail:

Project:

Enquiry for custom-made storage tanks

Cust

om-m

ade

tank

s

Page 88: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

88 I Accessories

Page 89: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 89

Additional plus: by regularly servicing and maintaining the heating system energy savings of up to 10 % can be made.

Did you know that...

Original Huch accessoriesEverything from a single source

The general warranty on our products is only maintained given that original Huch accessories are used for the prescribed maintenance and upkeep of the heating system.

High-grade magnesium anodesCompletes the corrosion protection of enamelled domestic water storage tanks.

Additionally fitted flangeFor bolt-on fitting of an electric heater or a fin tube heat exchanger as well as an inspection opening.

This is where you also find the right seal needed for servicing the storage tank.

Electric heatersFor additionally heating the heating and domestic water at peak times. This is where you find the right electric heater for the most varied of storage tank types.

1 1

2

3

3 2

Acce

ssor

ies

Page 90: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

90 I Accessories

Accessories

Additionally integrated flange» for the storage unit types PSX-F, PSX-F2, PSB-F2, SPSX-F, SPSX-F2» specified standard position, see pages with details on storage types» closed with seal and blind flange» flange for PSB-F2 is enamelled» flange for PSX and SPSX is primed» inspection flange for KWP» for the installation of a finned tube heat exchangers» for the installation of an electric heating

Storage type Nominal width [mm] Ø external [mm] Bolt circle [mm] Price [€/item]

PSB-F2 200 280 245 240,-

PSX-F, -F2 200 280 245 185,-

SPSX-F, -F2 200 280 245 185,-

KWP 200 280 245 185,-

Flange system for additional self-assembly» suited for any steel storage units without enamelling» including blind flange, seal and screwsOrder no. Nominal width [mm] Ø external [mm] Bolt circle [mm] Price [€/item]

11379 200 280 245 134,-

Blind flanges

Order no. Nominal width [mm] Ø external [mm] Bolt circle [mm] Hole pattern Design Storage type Price [€/item]

03683 110 180 150 8 x Ø14 uncoated 1 17,-

00046 200 280 245 12 x Ø16 uncoated 2 48,-

05148 200 280 245 12 x Ø16 one side enamelled 3 74,-

Blind flanges with connection sleeve G 1½“

Order no. Nominal width [mm] Ø external [mm] Bolt circle [mm] Hole pattern Design Storage type Price [€/item]

06202 110 180 150 8 x Ø14 enamelled 1 x G 1½“ 1 38,-

06201 200 280 245 12 x Ø16 uncoated 1 x G 1½“ 2 41,-

10358 200 280 245 12 x Ø16 uncoated 2 x G 1½“ 2 50,-

05619 200 280 245 12 x Ø16 enamelled 1 x G 1½“ 3 80,-

10452 200 280 245 12 x Ø16 enamelled 2 x G 1½“ 3 103,-

12539 110 180 150 8 x Ø14 Stainless steel 1.4571 1 x G 1½“ 4 171,-

Page 91: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 91

Reducing flange» Reducing flange for series type R electric heating for assembly in flange 280 x 210 x LK 245

Order no. Ø external [mm] Bolt circle [mm] Hole pattern Design Price [€/item]

12536 280 245 12 x Ø16 enamelled 97,-

12537 280 245 12 x Ø16 uncoated 97,-

Accessories

Flange seals

Design Flange seal Suitable for flange + storage tank

Order no. Design Hole pattern

Nominal width [mm]

Ø external [mm]

Bolt circle [mm]

Storage type Price[€/item]

03684 3 x 140 (plate) without 110 180 LK Ø 150, 8 x Ø14 1 without E-Hzg. 10,-

01429 4 x 200 x 280 12 x Ø15 200 280 LK Ø 245, 12 x Ø16 2 / 3 12,-

16830 3 x 130 x 210 10 x Ø14 150 210 LK Ø 180, 10 x Ø14 5 26,-

38777 3 x 100 x 180 8 x Ø14 110 180 LK Ø 150, 8 x Ø14 1 with E-HZG. / 6 22,-

47216 3 x 120 x 180 120 180 4 13,-

11561 3 x 410 x 495 18 x Ø13 410 495 LK Ø 462, 18 x Ø13 7 23,-

32342 4 x 139 x 110 without - - - 8 30,-

04034 3 x 142 x 210 10 x Ø14 140 210 LK Ø 180, 10 x Ø14 9 13,-

47217 3 x 220 x 290 220 290 10 20,-

47218 3 x 300 x 380 300 380 11 26,-

Did you know that...when delivered, the blanking-off flange is only hand-tightened with nuts at the flange. This does not ruin the seal should you wish to inspect the storage tank from inside before installation. Therefore firmly tighten the nuts once installation is over! Blind flange / seal / flange E-HZG / blind flange with sleeve / seal / flange

Storage tank type1 SSH 301-501, ESS-PU 200-500, BS 122-501, EBS-PU 120-500,

HLS-Plus 150-501, SSH-Plus 351-801, SSK 300-5007 SKSE, SKSV, SKSW, SKSP

2 PSX-F, SPSX-F 8 WWS-TS

3 SSH 751-2000, BS 751-2000, PSB 200-2000 9 Internal tank SKSE

4 HSS 200-1000, HBS 150-1000 10 HPS 200-500

5 WWS-SRO, SKSE 11 HPS 800-1000

6 SKSV

Acce

ssor

ies

Page 92: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

92 I Accessories

Accessories

Overview anodes installed in standard storage tanksAnode type Magnesium anode Impressed current anode

Order no. anode 05712 05713 05714 03679 04041 04042 04390 05328 10892 04509 24463 26054Price [€/item]: 24,- 28,- 29,- 31,- 35,- 52,- 59,- 21,- 24,- 250,- 401,- 401,-Design Anode

for storage type

standardØ 33 x

350 mm G 5/4"

standardØ 33 x

487 mm G 5/4"

standardØ 33 x

580 mm G 5/4"

standardØ 33 x

687 mm G 5/4"

standardØ 33 x

887 mm G 5/4"

standardØ 33 x

1087 mm G 5/4"

standardØ 33 x

1487 mm G 5/4"

insulatedØ 33 x

400 mm M8x30

insulatedØ 33 x

500 mm M8x30

insulated G 1 ¼"

1x 800 mm

insulated G 1 ¼"

2x 800 mm

insulated G 1 ¼"

1x 400mm1x 800 mm

ESS-PU 200 ■ESS-PU 300 ■ESS-PU 400 ■ESS-PU 500 ■SSH 301 ■SSH 401 ■SSH 501 ■SSH 751 ■SSH 1001 ■SSH 1500 ■SSH 2000 ■SSH-Plus 351 ■SSH-Plus 501 ■SSH-Plus 801 ■EBS-PU 120 ■EBS-PU 150 ■EBS-PU 200 ■EBS-PU 300 ■EBS-PU 400 ■EBS-PU 500 ■BS 122 ■BS 152 ■BS 202 ■BS 301 ■BS 401 ■BS 501 ■BS 751 ■BS 1001 ■BS 1500 ■BS 2000 ■HLS-Plus 150 ■HLS-Plus 200 ■HLS-Plus 301 ■HLS-Plus 401 ■HLS-Plus 501 ■HLS-Plus 801 ■PSB 200 ■PSB 300 ■PSB 400 ■PSB 500 ■PSB 750 ■PSB 1000 ■PSB 1500 ■PSB 2000 ■HSO 120 ■HSO 150 ■WWS-TS 120 ■WWS-TS 150 ■WWS-TS 200 ■SKSE 200 ■

Page 93: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 93

Protection anodes for enamelled tanks - Anoden exchange (maintenance) and retrofitting» magnesium protection anodes suited for all enamelled tanks with G 1¼“ anode sleeves» insulated anodes are required when used together with anode testers

insulated magnesium protection anode Optional insulated chain link anodeOrder no. Length [mm] Price [€/item] Order no. Number chain links Length [mm] Price [€/item]

10176 350 27,- – – – –

04616 700 33,- – – – –

05187 900 39,- 28717 6 + 1 1218 78,-

05188 1100 43,- 28716 8 + 1 1548 85,-

05295 Anode tester for control board assembly

17,- – – – –

Standard magnesium protection anode Optional chain link anodeOrder no. Length [mm] Price [€/item] Order no. Number chain links Length [mm] Price [€/item]

05712 350 24,- – – – –

05713 487 28,- – – – –

05714 580 29,- 15379 5 796 56,-

03679 687 31,- 05013 6 961 83,-

04041 887 35,- 14972 7 1126 73,-

04042 1087 52,- 17459 9 1456 88,-

Accessories

Impessed current anode» suited for all enamelled tanks with G 1¼“ anode sleeves» maintenance-free permanent anode as an alternative to magnesium protection anodes» 230 V socket required for wall power supply» including operating manual and circuit diagram

Order no. Installation depth [mm] for tank capacity [litres] Price [€/item]

11259 100 bis 300 142,-

10601 400 400 – 500 208,-

04509 800 from 750 - 1250 250,-

24463 2 x 800 (as Set) 1500 - 2000 401,-

26054 1x 400 / 1x 800 (as Set) SSH-Plus / HLS-Plus 800 401,-

CorroScout® 500 anode test device» measures the drive voltage of isolated magnesium protection anodes as well as Correx impressed current anodes against container/tank» measures protective currents (direct currents) as well as mains voltage (230V AC/115V AC)» measures the potential balancing resistance, the functionality of reverse polarity protection diodes as well as the internal resistance of control sensors up to max. 20 kΩ» Scope of delivery: measuring instrument, cable kit, test tips, crocodile clips, operating manual

Order no.: 17780 Price [€/item]: 125,-

Order no. Details Storage tank type Price [€/item]

28246 Conversion kit for M8 anodes WWS-SRO, WWS-TS, Combined storage tank 47,-

Note: Allow only authorised specialists to perform electrical connections according to the German VDE regulations and the provisions of theutility companies. This must also be observed for malfunctions and repairs. The combination with CrNi (NIRO) boilers is problematic and thus not recommendable.

Acce

ssor

ies

Page 94: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

94 I Accessories

Accessories

Series type R built-in electric heatings for enamelled storage unitsThe series type R built-in heatings are suited for a max. operating pressure of 10 bar; depending on their power, they include a corresponding number of high-quality tubular heaters which are mounted on a flange plate by means of a separately applied protective current resistor. The heating power is controlled by means of an externally adjustable thermostat. Moreover, each built-in heating is equipped with a safety temperature limiter which switches off the heating at all poles if the temperature controller fails. The complete wiring, control devices and connecting clamps are covered by black plastic caps. The required type of built-in heating can be selected from the provided table on the basis of the desired power and installation position, the available installation length and the required heating groups. For article 13598 (RSW 15 kW), a contactor control is required. The combination with CrNi (NIRO) boilers is problematic and thus not recommendable.

Order no. Type / Power [kW] Voltage [V] Depth [mm] Nominal width Flange-Ø [mm] Price [€/item]

15466 RDU 1 / 3,0 3~400 450 DN 110 180 / LK 150 8 x Ø14 380,-

16263 RDU 1 / 5,0 3~400 450 DN 110 180 / LK 150 8 x Ø14 380,-

14723 RDU 1 / 6,0 3~400 450 DN 110 180 / LK 150 8 x Ø14 380,-

21795 KDW 6 KW - 0 / 6,0 3~400 375 DN 110 180 / LK 150 8 x Ø14 380,-

14877 RDW 1 / 7,5 3~400 450 DN 110 180 / LK 150 8 x Ø14 420,-

12582 RDW 1 / 10,0 3~400 450 DN 110 180 / LK 150 8 x Ø14 420,-

12535 RSW 1 / 12,0 3~400 530 DN 110 180 / LK 150 8 x Ø14 485,-

13598 RSW 1 / 15,0 3~400 630 DN 110 180 / LK 150 8 x Ø14 548,-

Note: Allow only authorised specialists to perform electrical connections according to the German VDE regulations and the provisions of theutility companies. This must also be observed for malfunctions and repairs. The combination with CrNi (NIRO) boilers is problematic and thus not recommendable.

Built-in electric heating for enamelled and uncoated storage units» insulated electric heating especially for the use in enamelled solar storage units and storage units for industrial water as auxiliary or emergency heating» easy installation due to 1½“ screw head with male thread» unheated length 100 mm» not suited for continuous operation» 3 variants available 1) single-pole built-in electric heating with temperature preselection by means of a thermostat with a setting range of 3 - 68°C, preset at 55°C, and a safety temperature limiter at 87°C, antifreeze mode 2) U-shaped, three-pole built-in electric heating with temperature preselection by means of a thermostat with a setting range of 25 - 70°C and and a safety temperature limiter at 98°C, antifreeze mode 3) for PV systems with three heating elements which can be heated separately» for the installation in a blind flange, the corresponding blind flange with sleeve and seal must be ordered separately

Order no. Typ Power [W] Voltage [V] Installation length [mm]

Price [€/item]

09901 Screw-in electric heating EHK1-i 15 1500 230 400 146,-

09902 Screw-in electric heating EHK1-i 18 1800 230 400 146,-

09903 Screw-in electric heating EHK1-i 20 2000 230 400 146,-

09904 Screw-in electric heating EHK1-i 25 2500 230 400 146,-

09905 Screw-in electric heating EHK1-i 30 3000 230 400 146,-

09906 Screw-in electric heating EHK3-i 30 3000 400 390 205,-

09907 Screw-in electric heating EHK3-i 45 4500 400 470 209,-

09908 Screw-in electric heating EHK3-i 60 6000 400 550 239,-

09909 Screw-in electric heating EHK3-i 90 9000 400 780 285,-

32780 Screw-in electric heating EHK3-i PV 3000 400 / 230 390 207,-

32781 Screw-in electric heating EHK3-i PV 4500 400 / 230 470 212,-

32782 Screw-in electric heating EHK3-i PV 6000 400 / 230 550 242,-

EHK 1

EHK 3

EHK 3-iPV

Page 95: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 95

Built-in electric heating for stainless steel tanks» U-shaped, three-pole built-in electric heating» easy installation due to 1½“ screw head with male thread» round protective cap made of plastic / black» temperature preselection by means of a thermostat with a setting range of 25 - 70°C, a safety temperature limiter at 98°C and an antifreeze mode at 8°C» unheated length 100 mm» including operating manual and circuit diagram» for the installation in a blind flange, the corresponding blind flange with sleeve and seal must be ordered separatelyOrder no. Type Power [W] Voltage [V] Installation length [mm] Price [€/item]

09910 Screw-in electric heating EHK3 30 3000 400 290 235,-

09911 Screw-in electric heating EHK3 45 4500 400 350 262,-

09912 Screw-in electric heating EHK3 60 6000 400 450 248,-

09913 Screw-in electric heating EHK3 90 9000 400 650 274,-

09914 Screw-in electric heating EHK3 120 12000 400 750 285,-

Built-in electric heating for combined storage units (for units from a total capacity of 800 litres)» built-in three-pole electric heating, coiled» easy installation due to 1½“ screw head with male thread and made of stainless steel» temperature preselection by means of a thermostat with a setting range of 30 - 85°C, a safety temperature limiter at 110°C and an antifreeze mode at 6°C» unheated length 100 mm

Order no. Typ Power [W] Voltage [V] Installation length [mm] Price [€/item]

09915 Screw-in electric heating EHK-KS 40 4000 230 275 271,-

09916 Screw-in electric heating EHK-KS 40 4000 400 275 280,-

Accessories

Cu finned tube heat exchanger» Finned tube heat exchanger for heating hot water or buffer storage units» Huch storage units with a flange diameter of 280 mm can be easily retrofitted with these heat exchangers. The required blind flange plates and seals are included in the scope of supply.» all joints are brazed with silver solder» the outside of the finned tube heat exchangers are galvanically tin-plated» the electrically insulated connection fittings (required for drinking water storage units with anode protection) are supplied together with the heat exchanger» different sizes available (single and double coil)» max. operating pressure 10 bar, max. operating temperature 150 °C

Type BW 10-1 BW 13-1 BW 18-1 BW 23-1 BW 26-2 BW 31-2 BW 36-2 BW 45-2Heating surface [m²] 1,0 1,2 1,8 2,3 2,5 3 3,6 4,5Continuous output [kW] 17 21 33 39 40 48 58 72Connection [Inch] R ½ R ¾ R ¾ R ¾ R 1 R 1 R 1 R 1Installation sizesD [mm] 140 147 170 170 175 175 175 175L [mm] 350 410 440 540 510 540 650 790a [mm] 40 50 60 60 48 48 48 48g / h [mm] – – – – 45 / 110 45 / 110 45 / 110 45 / 110Complete installation kit (for uncoated storage units)Order no. 17664 17666 17668 17670 17672 17674 17676 17678Price [€/item] 451,- 500,- 606,- 701,- 790,- 946,- 1319,- 1226,-Complete installation kit (for enamelled storage units)Order no. 17665 17667 17669 17671 17673 17675 17677 17679Price [€/item] 545,- 560,- 619,- 697,- 781,- 960,- 1011,- 1232,-

a

a

70±3

gh

15±1,5

G

G

L

L

D

D

Acce

ssor

ies

Page 96: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

96 I Accessories

Accessories

MiscellaneousOrder no. Description Price [€/item]

05298 Thermometer with sensor for control board assembly 25,-

06209 3 levelling feet for storage unit with foot ring up to max. 500 litres 30,-

06210 4 levelling feet for storage unit with foot ring up to max. 1000 litres 37,-

14499 3 levelling feet for EBS/ESS-PU 16,-

14498 Temperature display for EBS/ESS-PU (thermometer incl. sleeve 55 mm M8) 15,-

06596 Temperature display for storage unit with 80 mm polyline fleece insulation (thermometer incl. sleeve 80 mm M8)

15,-

06597 Temperature display for storage unit with 100 mm polyline fleece insulation(thermometer incl. sleeve 100 mm M8)

16,-

17446 Industrial bimetallic thermometer 12,-

38319 Cover strip for hook closure strip polyline fleece insulation (800 x 90 x 1.5 mm) 12,-

38323 Assembly aid for hook closure strip polyline fleece insulation (100 x 90 x 1.5 mm) 9,-

29318 Expansion sleeve (set of 2 pcs.) 23,-

22933 flexible storage tank connection including a corrugated pipe made of stainless steel, length 200 - 300 mm, 1 ½'' IG 34,-

46771 storage tank connection including a corrugated pipe made of stainless steel, length 300 mm, 1 ½'' AG 57,-

20851 Universal assembly kit (complete kit incl. mounting material)

Assembly kit for the storage unit and wall assembly of many common freshwater replacement stations, optionally also suited for solar stations (max. distance of fixation points W x H 560 x 540 mm); quick and easy assembly; variably adjustable by means of profile rails

57,-

Internal tank for combined storage tanksOrder no. Description Price [€/item]

05079 Internal tank for combined storage tank 200 litres 10 bar enamelled 693,-

11500 Internal tank for combined storage tank 200 litres 10 bar stainless steel 1212,-

26502 Internal tank for combined storage tank ~27 litres 5 m² stainless steel corrugate pipe 1" 1011,-

26505 Internal tank for combined storage tank ~43 litres 8 m² stainless steel corrugate pipe 1" 1120,-

11561 Seal for internal container 23,-

Fig. Universal assembly kit

Circulation lance» circulation lance for circulation connection to the hot water discharge of combined storage units with corrugated pipes made of stainless steel (SKSW)» circulation only in the upper part (approx. 1m) of the corrugated pipe» consisting of: • T-piece R 1“ x 95 mm long • PE-Xc plastic pipe 8 x 1.0 x 1000 mm long with adaptor • transition screw connection R1“/G 1“ x 50 mm long • total structure height approx. 130 mm

Order no.: 26134 Price [€/item]: 132,-

Page 97: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 97

Fittings kits for compressed air tanks» ZA safety valve MS R ½“ or 1“; Sleeve ½“ or 1“ » Filling and draining valve for boilers ½“ or 1“ » Three-way valve ½“ or 1“ Fig. 34 MS ; Manometer 0 - 25 bar » Bracket ½“ or 1“ I/A no.92 ; Wika seal Cu. ½“ or 1“

Order no. Description Price [€/item]

01420 Fittings kit ½“ up to 1000 Litres / 11 bar 185,-

01421 Fittings kit ½“ up to 1000 Litres / 16 bar 175,-

01422 Fittings kit 1“ up to 3000 Litres / 11 bar 230,-

01423 Fittings kit 1“ up to 3000 Litres / 16 bar 238,-

Accessories

Boiler accessoriesOrder no. Description Price [€/item]Pressure switch00906 MDR 5/5 max. Switch-off pressure 5 bar 119,-00913 MDR 5/8 max. Switch-off pressure 8 bar 159,-01407 MDR 5/11 max. Switch-off pressure 11 bar 175,-12510 MDR 4S/6 max. Switch-off pressure 6 bar 129,-Water level display up to 6 bar00911 1 pair of water level display fittings ½” 80,-00909 Water level pipe Ø 12mm 680 mm up to 750 litres 19,-00910 Water level pipe Ø 12mm 980 mm from 1000 litres 23,-41167 Seal for water level pipe 5,-41168 Collar ring 8,-Water level display up to 10 bar01417 1 pair of water level display fittings ½” rugged design 138,-01418 MS protective tubes (brass) 950 mm 140,-01419 Borosilicate glass tube Ø 12mm 980 mm 40,-Further accessories01408 1“ spring non-return valve 30,-01409 1¼“ spring non-return valve 40,-01410 1½“ spring non-return valve 48,-01395 Ventilation valve ¼“ Fig. 406 47,-00912 Drain cock ¼“ made of brass 50,-01791 Handhole closure, complete 100 x 150 mm, 6 bar, zinc-plated 30,-15116 Handhole closure Orpu, complete 100 x 150 mm, 6 bar, zinc-plated 41,-01903 Manhole closure, complete 320 x 420 mm, ring height 90 mm, 10 bar 371,-02407 Rubber seal HLV 100 / 130 x 150 / 180 x 6 (oval) 13,-01494 Rubber seal HLV (Orpu) 93 / 143 x 138 / 188 x 4 10,-01005 Seal (manhole closure) 320 / 370 x 420 / 470 x 10 89,-01393 Manometer (please indicate pressure stage on your order) 6 bar 15,-01406 Manometer ¼“ 0 - 10 bar 9,-

Pressure switch Manometer Drain cock Ventilation valve Water leveldisplay fitting

Handholeclosure

Manholeclosure

Acce

ssor

ies

Page 98: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

98 I Fire bowls & accessories

© panthermedia.net / Ingrid Balabanova

Page 99: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 99

Fire bowls & garden accessoriesA system with considerable scopeHuch fire bowls ensure a cosy fire and pleasant warmth even on cool days. Huch fire bowls can be had in various sizes and materials. Perfectly adapted accessories ensure that any Huch fire bowls provides a complete system with numerous possibilities.

+ Accessories I The accessories round off the fire bowls system.

+ Cooking & barbecue accessories I The hot pan and barbecue variants provide considerable scope for outdoor cooking.

+ Additions I Combined with an attractively designed fitting, you can more safely handle the fire. The cover provides op-timum protection from any sparks flying around once that enjoyable evening is over.

The Huch fire bowls as Basis I Even during cooler evenings, the pleasant heat from Huch’s tried-and-tested fire bowls ensures a cosy camp-fire atmosphere.

Fire

bow

ls &

acc

esso

ries

Page 100: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

100 I Fire bowls & accessories

Fire bowls and garden accessories

Fire bowl» 2 rugged handles » S235JR+N steel» 3 rugged feet for secure stand even on slightly uneven ground» available in different sizes» Special sizes on request

Order no. Product / Size [mm]

02396 Fire bowl standard - S, ø 550 (10 kg)

06091 Fire bowl standard - M, ø 750 (15 kg)

04987 Fire bowl standard - L, ø 850 (18kg)

11281 Fire bowl standard - XL, ø 1000 (22 kg)

28329 Fire bowl special sizes, ø 175 mm (1 kg)

28331 Fire bowl special sizes, ø 250 mm (1,5 kg)

27197 Fire bowl special sizes, ø 1250 mm (38 kg)

28107 Fire bowl special sizes, ø 1500 mm (70 kg)

28760 Fire bowl special sizes, ø 1600 mm (81 kg)

Lid for standard fire bowls» for increased safety after use, no flying sparks» 2 rugged handles » S235JR+N steel» available in different sizes» delivery without fire bowl (to be ordered separately)

Order no. Product / H x B x T [mm]

26570 Lid for fire bowl S / 40 x 650 x 570

26582 Lid for fire bowl M / 45 x 850 x 770

26583 Lid for fire bowl L / 50 x 950 x 870

26584 Lid for fire bowl XL / 55 x 1100 x 1020

Fire bowl - stainless steel» 2 rugged handles » 3 rugged feet for secure stand even on slightly uneven ground» stainless steel» available in different sizes

Order no. Product / Size [mm]

28418 Fire bowl stainless steel - S, ø 550 (8 kg)

29545 Fire bowl stainless steel - M, ø 750 (14 kg)

Top piece for fire bowl» with and without flame pattern» 2 handle recesses » suitable for Huch fire bowls » S235JR+N steel» available in different sizes » delivery without fire bowl (to be ordered separately)

Order no. Product / H x ø [mm]

28559 Top piece with pattern for fire bowl S, 340 x ø 530

28340 Top piece with pattern for fire bowl M, 340 x ø 730

31735 ATop piece with pattern for fire bowl L, 340 x ø 830

31378 Top piece with pattern for fire bowl XL, 400 x ø 980

28558 Top piece without pattern for fire bowl S, 340 x ø 530

28339 Top piece without pattern for fire bowl M, 340 x ø 730

31737 Top piece without pattern for fire bowl L, 340 x ø 830

- Top piece without pattern for fire bowl XL, 400 x ø 980

Hot pan for standard fire bowls» Combined pan and wok for preparing delicious food» rugged handles » suitable for Huch fire bowls » available in different sizes » delivery without fire bowl (to be ordered separately)

Order no. Product

26424 Hot pan for fire bowl S - ø 550 mm (14 kg)

26425 Hot pan for fire bowl M - ø 750 mm (22 kg)

26564 Hot pan for fire bowl L - ø 850 mm (28 kg)

26565 Hot pan for fire bowl XL - ø 1000 mm (36 kg)

Tripod» rugged telescope bars» adjustable in height» anodised» suited for cooking grate and stew pot» delivery without fire bowl and stew pot (to be ordered separately)

Order no. Product / Height [mm]

37002 Tripod, 1700 mm (ca. 5 kg)

Cooking grate » Stainless steel Cooking grate ø 500 mm» incl. chains» suited for grill gallows and tripod

Order no. Product / Size [mm]

37019 Cooking grate ø 500 mm, incl. chains

Page 101: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 101

Fire basket» with flame pattern» 4 handle recesses » S235JR+N steel

Order no. Product / H x W x D [mm]

36586 Fire basket with pattern, 600 x 400 x 400 (22 kg)

Plug-in cooking grate for standard fire bowls - S» Stainless steel cooking grate ø 500 mm» 3 cooking grate holders for plug-in» only for Huch fire bowl ø 550 mm» delivery without fire bowl (to be ordered separately)

Order no. Product

37273 Plug-in cooking grate for fire bowl S, ø 550 mm

Grill gallows for standard fire bowls» for classic barbecue pleasure» rugged design » adjustable in height due to chains» Stainless steel cooking grate ø 500 mm» only for Huch fire bowls ø 750 mm and ø 850 mm» delivery without fire bowl (to be ordered separately)

Order no. Product / H x W x D [mm]

36679 Grill gallows for fire bowl standard - M (ø 750 mm) and L (ø 850 mm), 1300 x 750 x 770 mm, ca 8 kg

Stew pot» enamelled» sizes: 14 litres, 22 litres

Order no. Product

36983 Stew pot - 14 Litres

36995 Stew pot - 22 Litres

Wooden spoon» natural wood

Order no. Product / Length [mm]

36989 Wooden spoon, 600 mm

Charcoal plate» For good ventilation of the fire and less charcoal» 3 mm Steel S235JR+N

Order no. Product / Length [mm]

45323 for fire bowl standard - S (ø 550 mm)

46765 for fire bowl standard - M (ø 750 mm)

Protection plate for Fire bowl» Protects sensitive floors against ashes, sparks or falling embers» 2 rugged handles » 3 mm Steel S235JR+N

Order no. Product / Diameter [mm]

46759 Protection plate ø 600 mm for fire bowl standard - S (ø 550 mm)

46760 Protection plate ø 850 mm for fire bowl standard - M (ø 750 mm)

Prices on request!More information, recipes and care instructions atwww.huch-feuerschale.de!

Note: the steel S235JR+N is uncoated and can rusting!

Fire

bow

ls &

acc

esso

ries

Page 102: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

102 I www.huch.com

Since we continuously enhance our products, we reserve the right to change our products, our range of products and our prices at any time without prior notice. We do not assume any liability for possible typographical mistakes or errors. Any claims, in particular damages, are excluded! The illustrations included herein have symbolic character and do not necessarily comply with their actual design.

» Our General Terms and Conditions for Sale and Delivery as well as the agreements acknowledged with order acceptance shall apply to all transactions.

» All prices are non-binding end customer prices and do not include value-added tax.» Our products are exclusively sold by wholesalers.» With the publication of this price list, any other previous price lists shall cease to be valid.» In order to maintain warranty, only original parts may be used as replacement parts such as seals, anodes, etc. » Technical data sheets and texts for invitations to tender are provided on our website at www.huch.com

CopyrightHuch GmbH Behälterbau, Neuruppin, Germany. Anything from this issue may only be copied or published in any other way with prior written or oral approval and if the source is indicated.The data mentioned only apply to the application of Huch products. Huch does not assume any liability for incorrect use, application or the false interpretation of technical data. Huch GmbH Behälterbau further points out the applicable General Terms and Conditions for Sale and Delivery (AGB). Image copyrights: Product illustrations - www.huch.com, images - panthermedia.net.

Declaration of ConformityThis is to declare the conformity for the hot water tanks (product group 01-05) included in this price list according to the:

DELEGATED RESOLUTION (EC) No. 812/2013 OF THE COMMISSION of 18 February 2013 as amendment of Directive 2010/30/EC of the European Parliament and the Council with regard to the energy efficiency labelling of water heaters, hot water tanks and composite systems consisting of water heaters and solar equipment

and

RESOLUTION (EC) No. 814/2013 OF THE COMMISSION of 2 August 2013 implementing Directive 2009/125/EC of the European Parliament and the Council with regard to the specification of requirements for the environmentally-friendly design of water heaters and hot water tanks.

All devices meet the requirements of the regulations as of the applicable effective dates and are provided with the CE mark.

Important notes regarding this price list

A/A1/A2 Connection

AG male thread

ANO1/ANO2 optional anodes

E-HZG electric heating

F/F1/F2 Sensor/controller connections

G separated

GWT Bare-tube heat exchanger

HLV hand hole closure

HS rigid foam insulation

IG female thread

KW cold water

max. P HZG maximum pressure of heating

max. P TW maximum pressure of drinking water

max. P WT-HZG max. pressure of heat exchanger heating

max. T maximum temperature

NL number key performance indicator of the storage tank

R male thread, conically sealing

RFL inspection flange

RL (a) external return flow of heat exchanger

RL (i) internal return flow of heat exchanger

RL/RL 1/RL2 heat exchanger (return flow)

Rp female thread, conically sealing

TW corrugated pipe corrugated pipe for drinking water

Vl fleece insulation

VL (a) external inlet flow of heat exchanger

VL (i) internal inlet flow of heat exchanger

VL/VL 1/VL 2 heat exchanger (inlet flow)

WT heat exchanger

WW hot water

Z Circulation

Abbreviations

Page 103: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

www.huch.com I 103

§ 1 ScopeAll agreements, offers and deliveries are carried out exclusively on the basis of the business conditions given below. Thus, they also apply to future business relations, even if they are not separately agreed upon.Differing, conflicting or supplementary General Terms and Conditions of Business shall not, even upon knowledge thereof, become part of the contract, unless their application is expressly agreed to in writing Terms and conditions of the contrac-ting party that we have not expressly acknowledged are invalid.§ 2 Delivery contract1 Our offers are without obligation. Technical changes as well as changes in form, colour and/or weight are reserved

within reasonable limits.2 Dimensions, weights, illustrations and drawings, including all information and illustrations in brochures and catalogues,

shall only be binding if this is expressly agreed in writing. Information and illustrations contained in brochures and catalogues are, in accordance with usual trade practice, regarded as approximations unless they have been expressly described by us as binding. In the event that any of the parties to the contract provides the other party with designs or technical documents with regard to the goods to be delivered or their production, such material shall remain the property of the providing party.

3 Partial deliveries are permissible within our specified delivery times, provided that this does not result in disadvanta-ges for the use of the goods.

4 Once the customer places an order for a product they declare their intention to buy the ordered goods as binding. We are entitled to accept the contractual offer made in the order within two weeks after receipt by our company. Accep-tance can be declared either in writing or by the delivery of goods to the customer.

5 If the customer has ordered the merchandise via electronic channels, we shall save the contract text and supply it to the customer on request along with these General Terms and Conditions by e-mail.

6 In the event of industrial disputes or unusual and unforeseeable events, such as actions of a government or any other state authority, traffic interruptions and/or force majeure, we shall be entitled to carry out the delivery only after the problem concerned has been rectified or be exempt from the obligation to deliver, if delivery is rendered impossible. The supplier shall notify the buyer without delay of the beginning and the end of any such event.

7 The quality of the goods is based solely on the agreed technical delivery regulations. If we are to deliver according to drawings, specifications, patterns etc. provided by the customer, then the customer shall accept the risk of the product's suitability for its intended use. The instant of passing the risks is decisive for the contractual condition of the goods. In this respect, we shall be liable only for the proper processing. If not expressly agreed upon, we shall not be held respon-sible for determining the material quality nor for any defects caused by corrosion.

§ 3 Delivery periods1 Unless otherwise agreed, we deliver "ex works". For meeting the delivery date or the delivery deadline, the notification by

us that the consignment is ready for shipping or collection is decisive.2 Delivery times are binding only if we have expressly designated them as such and confirmed them in written form.3 The period for delivery begins with the dispatch of the confirmation of order, but not before the provision [...] of any do-

cuments, approvals and clearances to be furnished if necessary by the customer and before the receipt of any agreed down payment. If, at a later stage, errors are detected in the order documents or drawings or it is found that necessary technical information is missing, then the delivery time begins anew upon rectification of the problems concerned.

4 It is considered that the delivery deadline has been complied with, if the delivery object has left the supplier's factory before the expiry of this deadline or if the supplier has notified the readiness for shipping on his part.

5. Part deliveries are permissible within the delivery periods specified by us, as long as there are no disadvantages for the use thereof.

6. The conclusion of the contract is subject to the correct and timely self-delivery by our suppliers. This only applies to cases in which we are not culpable for the non-delivery, in particular if a congruent coverage transaction is concluded with our supplier.7. If the delivery is not made at the agreed delivery date for reasons for which the customer is responsible, the purchaser

shall default in acceptance without a separate deadline being required by us. Each new delivery date must be confirmed by us in writing.

§ 4 Payment1 Unless otherwise agreed, all prices shall be ex works, i.e. plus a flat rate for shipping and plus the applicable VAT. Any

discount for cash must be agreed separately. We consider ourselves bound by the prices quoted by us and the terms of payment for the period indicated in the quotation. After the expiration of this period, we shall be entitled to make a reasonable price adjustment.

2. If the delivery can not be made within the deadline stated in the confirmation of order, we are entitled to demand negot-iations on an appropriate price adjustment. If an agreement cannot be reached within 6 weeks after our call for nego-tiations, we shall be entitled to cancel the contract and charge already rendered services and expenses on the basis of the contract price. The invoice amount shall be due within the agreed payment targets. If the customer defaults in payment, they shall pay interest on the monetary debt at a rate of 8 per cent points above the basic rate of interest of the EZB during the default in payment. We reserve the right to prove and assert higher damage caused by said default.

3 The customer may only exercise any rights of retention if their counterclaim is based on the same contractual relati-onship. The client is only entitled to set off counterclaims subject to final judgement or if accepted by us.

4 Non-compliance with the agreed payment conditions, and circumstances that become known to us after the conclusi-on of the contract and lead us to fear that the ordering party will be unable to pay in time, entitle us to request a security payment for all the claims from the delivery contract, regardless of the due date, and to suspend work until the security has been paid.

5 In the case of delayed payment we may suspend fulfilment of our obligations up to receipt of the payments after written notification of the purchaser.

6 Bills of exchange and cheques will only be accepted where this has been agreed, and only on account of performance and on condition that they may be discounted. Discount charges will be calculated from the due date for payment of the invoice amount. A guarantee that the bill and cheque will be presented on time and for the bill protest is precluded.

7. Price changes are permissible if more than four months have elapsed between the conclusion of the contract and the agreed delivery date (also for partial deliveries and partial installments). If, thereafter until completion of the delivery, the wages or material costs increase, we shall be entitled to increase the price appropriately in correspondence with the cost increases. The customer is only entitled to cancel if the price increase does not or not considerably exceed the consumer price index between the time of ordering and delivery.§ 5 Shipping and Transfer of Risk1 Goods reported as ready for dispatch shall be taken over by the partner without delay. Otherwise we shall be entitled

at our discretion to despatch or store them at the expense and risk of the partner.2. In the absence of any special agreement, we will select the means of transport and the transport route.3 With transfer to the railway, the forwarding or shipping company or with the start of the storage, at the latest however with

the departure from the plant or warehouse, the risk shall pass to the partner even if we have taken over the delivery.4 Insurance cover for transit damage is provided only on request and at the cost of the customer.§ 6 Default in delivery1 If we are able to anticipate that it will not be possible for the goods to be delivered within the delivery period, we will

immediately inform the partner of the reasons for this, and also if possible indicate the probable delivery date.2 In the event of delivery being delayed by one of the circumstances as set forth in § 2, or as a result of any action or

omission on the part of the partner, an extension of the delivery period will be granted appropriate to the circumstances.3 The partner is only entitled to withdraw from the contract if we are responsible for the delivery date not being met and

the partner has allowed us a reasonable period of grace without result.§ 7 Retention of title1 We reserve the title in the goods until full payment of any accounts receivable from a current business relationship,

irrespective of the legal foundation on which it is based. In case of running account, retention of title is deemed as security for our balance claims. This is even applicable when payments are made by the customer on especially desi-gnated claims.

2 The customer shall be obligated to treat the goods delivered with due care. Where maintenance and inspection work is necessary, the customer must carry this out regularly and at their own cost.

3 The processing or alteration of the reserved goods shall always be made for us as the manufacturer without our incur-ring any obligation from this. When processing or reorganisation of the reserved goods with other goods not delivered by us, the co-ownership of the new object is entitled to us according to the ratio of the reserved goods' value to the value of the other product which has been processed and reorganized at the time of processing or reorganization. In case our ownership of the reserved goods expires due to connection or confusion, the customer already now assigns their (co)-ownership of the new object or of the commingled merchandise to the amount of the invoiced value of the reserved goods to us and keeps them safe free of charge for us. The new object (called "new object" in the following), created by processing, reorganization, connection or confusion, or the (co)-ownership of the new object being the entitled or assigned to us according to subsection 2 of this section, respectively, serves to secure our claim in the same way as the reserved goods according to subsection 1 themselves. Unless nothing divergent arises from the following provisions regarding these subsections, this securing of claims is to be applied accordingly to the new object.

4 The customer may further sell the reserved goods only within the framework of the correct business transactions, subject to the usual business conditions and only as long as they do not default their payment obligations towards us. The customer is obliged on their part to further sell the reserved goods subject to reservation of title only and to ensure that the claims arising from such disposal activities may be transferred to us.

5. The customer's claim arising from the resale of the reserved goods is already assigned to us. These claims serve as a security to the same extent as the goods under reservation of ownership. If the customer sells the retained goods together with other goods that were delivered by other parties, then the assignment of the account receivable extends only to the pro-rata amount of invoice that represents the retained goods resold. The assignment of claims as regards the sale of the goods as stipulated in subsection 2 or in the legal provisions regulating the connection and confusion of the object of which we are co-proprietor shall be applied in the amount of our partial ownership.6 If the customer includes accounts receivables from retained goods resold in a mercantile current account relationship

that The preceding sub-paragraph is applied in so doing.7 The customer is entitled to retract the claim arising from the further sale of the reserved goods that had been assigned

to us. They are not entitled, however, to assign the claim arising from the further sale, not even in the context of a genuine factoring contract.

8 In this case the customer is obliged to immediately inform their buyers of the assignment of the claim as well as to hand over to us any documents, certificates and information necessary to justify and implement the claim.

9 If the realizable value of the securities at our disposal exceeds our secured claims by more than 15 %, we are prepared, upon request by the customer, to release securities, chosen by us, to this extent.

10 The customer is obliged to notify us immediately of any levy of execution or any other legal or actual hazard for the retained goods or for the other collateral that exists for our benefit.

11 The customer pledges to sufficiently insure the reserved goods against fire and theft. The customer hereby assigns to us in advance its claims from insurance contracts.

12 If the customer breaches the contract, particularly in the event of payment default or infringement of one of the obli-gations of this section, we have the right to cancel the contract and require the return of the goods. For this case, the customer already now agrees to our removing or having the reserved goods removed which were with the customer or - in the case of us being the sole owners - the new object as per subsection 2 of this section, respectively. For the purpose of undertaking these measures as well as for the purpose generally inspecting the retained goods or the new object, the purchaser shall grant us, or persons authorized by us, access to their premises at any time.

§ 8 Warranty1 We are not liable for material defects which result from unsuitable or inappropriate use, incorrect assembly commissi-

oning by the customer or third parties, usual wear, incorrect or careless treatment, as well as for the consequences of inappropriate changes and modifications or repairs, made without our consent by the purchaser or third parties. The same applies for defects that only negligibly reduce the value or serviceability of the goods.

2 We must be given the chance to ascertain the reported defect. The corresponding goods are to be sent back to us immediately on demand. Should the customer fail to observe this obligation, or make modifications to such goods without our approval, they will lose any rights they may have on the grounds of product deficiency.

3 Initial warranty for defective merchandise is initially provided in the form of remedial repair or replacement according to our choice.4 If the subsequent performance fails, the customer may generally at its discretion demand a lowering of the payment

(reduction) or termination of the contract (withdrawal). In the event of a minor infringement of the contract, particularly for marginal defects, the customer is not entitled to cancel the contract.

5 In the case of obvious defects, the customer is obliged to immediately notify us in written form, at the latest within two weeks as of the receipt of the goods. Otherwise, assertion of the warranty claim shall be excluded. The punctual dispatch is sufficient for compliance with the warranty conditions. The customer shall be fully subject to the onus of proof for any reasons for claims, in particular for the defects as such, for the time of detecting the defect and for any notification of the defect being made in due course. In the case of acceptance having been agreed with the customer, the goods shall be considered approved upon acceptance. Otherwise, the assertion of the warranty claim is excluded and the goods shall be deemed approved, unless the defect is one that could not be detected during the careful ins-pection at the acceptance.

6 In case the customer chooses cancellation of the contract after the subsequent performance due to a defect failed, they shall not be able to claim additionally compensation for this defect. If the customer should choose to claim compensation for failure of subsequential fulfilment, the delivery item remains with the customer, provided that this is acceptable to them. The compensation is limited to the difference between the purchase price and the value of the defective good. The above shall not apply should we be guilty of malicious contract infringement. For contractors, the warranty term is 1 year from the delivery of goods. This does not apply if the customer has not informed us promptly of a defect. (Subsection 3 of this provision).

7 Generally only the product description of the manufacturer shall be deemed to be the agreed characteristics of the goods. Public statements, claims or advertisements by the manufacturer (of the product or individual components thereof) do not constitute contractually guaranteed characteristics of the goods. If the customer receives deficient assembly instructions, we shall be merely obligated to supply error-free assembly instructions and this also only if the error in the assembly instructions stands in the way of proper assembly. If, due to reasons we are not responsible for, the products manufactured by us cannot be delivered within the agreed time, those parts that have already been manufactured will be parked in unroofed and unmonitored storage areas at the orderer's expense and risk. In this case, the warranty period shall commence with the storage of the goods. As remuneration for storing the manufactured goods, we charge 1 % of the overall order sum for every month of storage commenced. The storage costs become payable on conclusion of the respective month of storage.

8 Claims against us in case of ordinary and minor negligence are limited to the total contract value.§ 9 Other claims, liability1 Unless specified otherwise below, other claims and claims of a wider scope against us on the part of the partner are

excluded This particularly applies to claims for compensation arising from infringement of duty from contractual obligations and from tortuous acts. Therefore, we will not compensate lost profits or other damage to the assets of the partner.

2 The above mentioned limitations of liability shall not apply for malice aforethought and gross negligence of our legal representatives or senior employees or for culpable breaches of essential contractual obligations. In the event of culpable breach of substantial contractual obligations, we shall - except in cases of deliberate acts or gross negligence on the part of our lawful representatives or executives - only be liable in respect of the damage which is typical of the contract and reasonably foreseeable.

3 To the extent that our liability is excluded or limited, this applies equally to the personal liability of our employees, workers, personnel, legal representatives and vicarious agents.

§ 10 Confidentiality1 Each of the contracting parties undertakes to use all documents (including samples, patterns and data) and knowledge

which they receive in the course of the business relationship for the jointly pursued purpose and to maintain their secrecy towards third parties with the same care as exercised with regard to their own equivalent property if these are designated as confidential or the other party has an obvious interest in maintaining their secrecy. This obligation commences with the first receipt of documents or knowledge and terminates 36 months after the end of the business relationship. We claim copyright protection for our quotation and contract documents, drawings, drafts and const-ruction details including all variants. They must not be copied or made accessible to third parties without our prior consent. Any use by the ordering party or any other third party requires our prior written consent and will be charged accordingly.

2 This obligation shall not apply to documents and knowledge which are generally known or which were already known on receipt without the partner being committed to confidentiality, or which were subsequently transferred by a third party entitled to pass them on or which were developed by the receiving contractual partner without the use of con-fidential documents or knowledge of the other contractual partner. In case a contract is not awarded, any documents provided by us must be returned to us without request within 6 working days at the latest.

§ 11 Final provision1 The laws of the Federal Republic of Germany shall apply. The provisions of the UN Sales Convention shall not apply.2 For all conflicts resulting from this contract, if the customer is a qualified merchant, a corporate body under public

law or a public law entity with special public funds, claims are to be filed at the court which is responsible for our head office. We are also entitled to file a suit at the customer's head office location. This applies even if the customer does not have a general place of jurisdiction in Germany or their place of residence or everyday domicile are not known at the time of institution of legal proceedings.

3 The place of performance is 16818 Werder.4 lf individual provisions of the contract with the customer including these standard conditions and terms of business

should be or become partly or wholly legally invalid, the validity of the remaining provisions will not be affected by this. The regulation which is totally or partially ineffective will be replaced by a regulation which will approximate the economical success of the ineffective regulation as closely as possible.

5 Any transfers of rights and obligations of the customer arising from the contract concluded with us require our written consent in order to be legally valid.

General terms and conditions

Gene

ral t

erm

s an

d co

nditi

ons

Page 104: Valid from 01 July 2017 - Huch GmbH BehälterbauBiomass plant ... This is made use of by the compact hot water heat pump and represents an optimum ... It generates the hot water (domestic

Huch GmbH BehälterbauTemnitz-Park-Chaussee 2216818 Werder (near Neuruppin)Germany

Telephone: +49 (0)33 920 - 672 0Telefax: +49 (0)33 920 - 672 72E-mail: [email protected]

Quality connects.

Find us atFacebook!

Your contact persons

You can contact our staff by telephone from Monday to Thursday from 7.30 am to 5.00 pm and on Friday from 7.30 am to 3.00 pm! Besides, you can, of course, always contact our staff by mail or fax.

Alexander SchulzTelephone: +49 (0)33920 - 672 51E-mail: [email protected]

Ramona RützTelephone: +49 (0)33920 - 672 50E-mail: [email protected]

Sven SzemkusTelephone: +49 (0)33920 - 672 66E-mail: [email protected]

Thomas KanigTelephone: +49 (0)33920 - 672 58E-mail: [email protected]

Anne SchulzeTelephone: +49 (0)33920 - 672 56E-mail: [email protected]

Christin MischTelephone: +49 (0)33920 - 672 53E-mail: [email protected]

Marcel WeckwerthTelephone: +49 (0)33920 - 672 35E-mail: [email protected]

Franziska GellertTelephone: +49 (0)33920 - 672 43E-mail: [email protected]

Andreas RischerTelephone: +49 (0)33920 - 672 26E-mail: [email protected]

Sales representation

Technical support Productmanagement

Sales NorthHead of sales

Sales South

Custom-made tanks offer department North / South

[5] Andreas SteinmüllerAm Wolfsberg 898704 Wolfsberg OT BüchelohTelephone: +49 (0)3677 - 89 49 49Telefax: +49 (0)3677 - 89 49 59Funk: +49 (0)171 - 61 06 088E-mail: [email protected]

[8] Michael SteinmüllerUnterpörlitzer Str. 32c98693 IlmenauTelephone: +49 (0)3677 - 66 72 983Telefax: +49 (0)3212 - 13 95 321Funk: +49 (0)170 - 48 19 203E-mail: [email protected]

[1+2+6] Sales rep by HUCHTemnitz-Park-Chaussee 2216818 Werder (near Neuruppin)Telephone: +49 (0)33 920 - 672 0Telefax: +49 (0)33 920 - 672 72E-mail: [email protected]

[3] Frank WernickeAm Rottersberg 537339 Worbis-LeinefeldeTelephone: +49 (0)36074 - 30 288Telefax: +49 (0)36074 - 63 868Funk: +49 (0)171 - 83 13 266E-mail: [email protected]

[4] IMG Plüschke GmbHHöltenweg 9748155 MünsterTelephone: +49 (0)251 - 60 222Telefax: +49 (0)251 - 60 221E-mail: [email protected]

[7] Siegfried FaltisReisstr. 2786316 Friedberg-WestTelephone: +49 (0)821 - 26 23 69 57Telefax: +49 (0)821 - 26 23 69 58Funk: +49 (0)171 - 61 15 656E-mail: [email protected]

We produce in Germany and supply the European market and beyond.