Hard water and AnticaCa++ Solutions
Systhema d.o.o.Volčja Draga 100Slovenija - Europe Union
Phone: +386 (0)1 832 50 27Mobile: +386 (0)41 789143Mail: [email protected]
Contact person: Jože Romšak
Contact person: Ing. Stefania Kulkova
Jože Romšak s.p.Črna pri Kamniku 121242 StahovicaSlovenia - Europe Union
Andrej Keber BE (Bachelor of Engineering)
Mobile: +386 (0)41 719 321 +386 (0)40 - 746 259Phone: +386 (0)5 - 993 23 52
Slovak Republik
water internationalMag
Project copyrights, management, engineering and general contacts
Technical areas, development and technical support
Powel Antica s.r.o.Levocska 2080 01 PresovSlovakia
Phone: +421 907 201 499Fax: +421 51 7711 195Mobile: +421 907 201 499
- hard Water Treatment, - water scale solutions,- water ionisation,- water cleaning and filtering- ecological and health care areas and projects
Mail: [email protected] [email protected]: www.facebook.com/andrej.keber
European and worldwide partnership
International Sales DepartmentVer. 1.0
MSc. Lidija Kocuvan Gašperič
Organisation, management andeditorial on ecology, water areas & healthcare
Mobile: +386 (0)40 740 997Mail: [email protected]: www.facebook.com/li.kocuvan
www.val-voda.si
www.euvantica.comwww.waterscale.eu
www.val-water.com
www.val-voda.siwww.val-water.com
![Page 2: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/2.jpg)
Hard water and AnticaCa++ Solutions
Systhema d.o.o.Volčja Draga 100Slovenija - Europe Union
Phone: +386 (0)1 832 50 27Mobile: +386 (0)41 789143Mail: [email protected]
Contact person: Jože Romšak
Contact person: Ing. Stefania Kulkova
Jože Romšak s.p.Črna pri Kamniku 121242 StahovicaSlovenia - Europe Union
Andrej Keber BE (Bachelor of Engineering)
Mobile: +386 (0)41 719 321 +386 (0)40 - 746 259Phone: +386 (0)5 - 993 23 52
Slovak Republik
water internationalMag
Project copyrights, management, engineering and general contacts
Technical areas, development and technical support
Powel Antica s.r.o.Levocska 2080 01 PresovSlovakia
Phone: +421 907 201 499Fax: +421 51 7711 195Mobile: +421 907 201 499
- hard Water Treatment, - water scale solutions,- water ionisation,- water cleaning and filtering- ecological and health care areas and projects
Mail: [email protected] [email protected]: www.facebook.com/andrej.keber
European and worldwide partnership
International Sales DepartmentVer. 1.0
MSc. Lidija Kocuvan Gašperič
Organisation, management andeditorial on ecology, water areas & healthcare
Mobile: +386 (0)40 740 997Mail: [email protected]: www.facebook.com/li.kocuvan
www.val-voda.si
www.euvantica.comwww.waterscale.eu
www.val-water.com
www.val-voda.siwww.val-water.com
![Page 3: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/3.jpg)
water international
Water treatment,ecology, awareness
www.bogastvozdravja.si
Wealth of Health
![Page 4: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/4.jpg)
water international
Water treatment,ecology, awareness
www.bogastvozdravja.si
Wealth of Health
![Page 5: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/5.jpg)
![Page 6: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/6.jpg)
![Page 7: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/7.jpg)
PRINCIPLE OF FUNCTION - DEVICES AntiCa++ (PHYSICAL WATER TREATMENT)
La
NDv
i
i - coil current
- piping current
- active length
c
ii
p
p
Ca++HCO
HCO
3
3
-
-
CaCO3
H2
2
OCO
+ -
BEFORE TREATMENT
Fig.AFig.B
AFTER TREATMENT
DESCALING
Ca++R
Ca++
ELECTRONIC SCALE CONTROL UNIT
POWER
POWEL
ANTICA
AntiCa++ DEVICE
Ca ( ) H O + (CO ) + CaCOHCOagr2 2
2
232+ -
3
c
i
La
p
c(CO ) =
> e
>
eion power
G3. Constitutional
diagram
of
water
0
1
2
3
4
5
6
7
8
9
10
11
12
0 0,04 0,2 0,36 0,52 0,68 0,84 1μ 1,16 1,32 1,48 1,64
m -ion power
c
[mm
ol/
l]
pH
pH
y(
e
)
y(
r )
c( Ca 2+ )
c(HCO3 -)
Consideration
Before
treatment:
μ1
=
μr
or
μ1
>
μr
Ca2+
-
accumulated
surplus:
Δ
Ca
=
1
/
3
( μ1
- μr )
After
treatment
with
AntiCa++ device:
μ2
<
μr
liberated
CO2
agr
concentration
c(
CO2 )agr
=
1
/
3
( μr
- μ2 )
μ2 - zone of action
AntiCa++ device
μ1
-
actual
ion power
μr
-
equilibrium
point
The
graph
of the equilibrium curve y( r ),
evolutional line y( e ), pH, c( Ca2+
) and c(HCO3-)
curve is generated by AntiCa++ software.
![Page 8: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/8.jpg)
PRINCIPLE OF FUNCTION - DEVICES AntiCa++ (PHYSICAL WATER TREATMENT)
La
NDv
i
i - coil current
- piping current
- active length
c
ii
p
p
Ca++HCO
HCO
3
3
-
-
CaCO3
H2
2
OCO
+ -
BEFORE TREATMENT
Fig.AFig.B
AFTER TREATMENT
DESCALING
Ca++R
Ca++
ELECTRONIC SCALE CONTROL UNIT
POWER
POWEL
ANTICA
AntiCa++ DEVICE
Ca ( ) H O + (CO ) + CaCOHCOagr2 2
2
232+ -
3
c
i
La
p
c(CO ) =
> e
>
eion power
G3. Constitutional
diagram
of
water
0
1
2
3
4
5
6
7
8
9
10
11
12
0 0,04 0,2 0,36 0,52 0,68 0,84 1μ 1,16 1,32 1,48 1,64
m -ion power
c
[mm
ol/
l]
pH
pH
y(
e
)
y(
r )
c( Ca 2+ )
c(HCO3 -)
Consideration
Before
treatment:
μ1
=
μr
or
μ1
>
μr
Ca2+
-
accumulated
surplus:
Δ
Ca
=
1
/
3
( μ1
- μr )
After
treatment
with
AntiCa++ device:
μ2
<
μr
liberated
CO2
agr
concentration
c(
CO2 )agr
=
1
/
3
( μr
- μ2 )
μ2 - zone of action
AntiCa++ device
μ1
-
actual
ion power
μr
-
equilibrium
point
The
graph
of the equilibrium curve y( r ),
evolutional line y( e ), pH, c( Ca2+
) and c(HCO3-)
curve is generated by AntiCa++ software.
![Page 9: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/9.jpg)
Comparison of AntiCa++ to water treatement devices that work on the galvanic principle:
heavy metal
not dissolve anything in water
1. it dissolves zinc into the water which is a .2. the effect of the treatment is lost after certain distance behind the place of installation,3. the operating life is 10 to 15 years because the zinc anode melts (this depends on the water amount and composition)4. complicated and costly installation: - during the installation the pipe has to be interupted, - it is needed to use other valves for closing the water, new high quality and tightly installed joint, installation of bypass so that the water does not stop5. the devices must be cleaned regularly which requires a lot of manupulations,6. the devices causes the barrier inside the water pipes and can cause the pressure lost or can collect any dirt particles.
1. AntiCa++ is not in contact with drinking water therefore it does (no heavy metals or other dangerous elements)2. the effect of treatment is not lost - AntiCa++ protects ash pipeline of the lenght of 4 km in Kosice heating station3. the operating life is at least 20 years,4. installation is simple and cheap - no pipe interuption nor need for new valves nor bypass,5. no need for maintenance of the device, low power consumption (1 - 10 W depending on the type of AntiCa++)6. no barrier put into the pipes.
Features of devices that work on the galvanic principle:
Electronic Water Treatment AntiCa++
IMPORTANT
Powel Antica Ltd.
Levocska 2 www.waterscale.eu
080 01 Presov www.euvantica.com
Slovakia
Tel: +421 907 201 499, Fax: +421 51 77 11 195
Email: [email protected], [email protected]
Features of AntiCa++ Compact
ideal for home appliances (for pipe of diameter of 3/8 inch)
installation in front of:
›
›
›boilers
›washing machines
›dishwashers
›other expensive household machines
›
›
›
›
small and compact
for all materials of pipe
easilly mounted directly on the pipe
protects home appliances from hard lime scale deposits
and thus saves moneyresult of 18 years of experience with hard water treatment›
We quarantee quality, reliability and function!
We understand water...
Protection and prevention against the water scale
PRICE LIST OF DEVICES AntiCa++ FOR WATER TREATMENT
AntiCa++ Compact
![Page 10: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/10.jpg)
Comparison of AntiCa++ to water treatement devices that work on the galvanic principle:
heavy metal
not dissolve anything in water
1. it dissolves zinc into the water which is a .2. the effect of the treatment is lost after certain distance behind the place of installation,3. the operating life is 10 to 15 years because the zinc anode melts (this depends on the water amount and composition)4. complicated and costly installation: - during the installation the pipe has to be interupted, - it is needed to use other valves for closing the water, new high quality and tightly installed joint, installation of bypass so that the water does not stop5. the devices must be cleaned regularly which requires a lot of manupulations,6. the devices causes the barrier inside the water pipes and can cause the pressure lost or can collect any dirt particles.
1. AntiCa++ is not in contact with drinking water therefore it does (no heavy metals or other dangerous elements)2. the effect of treatment is not lost - AntiCa++ protects ash pipeline of the lenght of 4 km in Kosice heating station3. the operating life is at least 20 years,4. installation is simple and cheap - no pipe interuption nor need for new valves nor bypass,5. no need for maintenance of the device, low power consumption (1 - 10 W depending on the type of AntiCa++)6. no barrier put into the pipes.
Features of devices that work on the galvanic principle:
Electronic Water Treatment AntiCa++
IMPORTANT
Powel Antica Ltd.
Levocska 2 www.waterscale.eu
080 01 Presov www.euvantica.com
Slovakia
Tel: +421 907 201 499, Fax: +421 51 77 11 195
Email: [email protected], [email protected]
Features of AntiCa++ Compact
ideal for home appliances (for pipe of diameter of 3/8 inch)
installation in front of:
›
›
›boilers
›washing machines
›dishwashers
›other expensive household machines
›
›
›
›
small and compact
for all materials of pipe
easilly mounted directly on the pipe
protects home appliances from hard lime scale deposits
and thus saves moneyresult of 18 years of experience with hard water treatment›
We quarantee quality, reliability and function!
We understand water...
Protection and prevention against the water scale
PRICE LIST OF DEVICES AntiCa++ FOR WATER TREATMENT
AntiCa++ Compact
![Page 11: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/11.jpg)
DESCALING
Ca++R
Ca++
ELECTRONIC SCALE CONTROL UNITEUV DOM
min. 3 x DNmin. 3 x DN 200 mm
METALPLASTIC
Total hardness ( dH) < 16 16 - 24 24 - 32 32 - 40 > 40Num. of coils N + N 11 + 11 12 + 12 13 + 13 14 + 14 15 + 151 dH <=> 0,18 mmol / l <=> 0,36 mval / l <=> 17,8 ppm <=> 1,78 f oo
o
N x N x
ONLY FOR HOUSEHOLD !
CAUTION!
Devices EUV 15 DOM - 65 DOM
They are designed for simple applications, if the flow rate is within the limits given in the table 2.
In the case, when the flow rate is at the lower limit and any other circumstances do not prevent it, it is recommended to reduce piping diameter in the place of installation and use the device, which is smaller by one order. These devices are suitable for households.
Type of the device
Optimum flow rate
(m3/h)
Internal diameter of
piping (mm-inch)
Dimensions
(WxHxD mm)
EUV 15 DOM
0,1 - 0,3
15 (1/2")
110 x 70 x 55
EUV 20 DOM
0,2 - 0,6
20 (3/4")
110 x 70 x 55
EUV 25 DOM
0,3 - 0,9
25 (1")
110 x 70 x 55
EUV 32 DOM
0,4 - 1,4
32 (5/4")
160 x 96 x 61
EUV 40 DOM
0,8 - 2,3
40 (6/4")
160 x 96 x 61
EUV 50 DOM
1,2 - 3,5
50 (2")
160 x 96 x 61
EUV 65 DOM 2,0 - 6,0 65 (2 1/2") 160 x 96 x 61
SPECIFICATIONS:
Supply voltage: 230 V, 50 Hz (US model 110 V, 60 Hz)Consumption: EUV 15 - 25 DOM - 2 VA EUV 32 - 65 DOM - 6 VAWorking period: min. 20 yearsWorking temp.: 0 C to 40 CWeight: EUV 15 - 25 DOM - 0,5 kg EUV 32 - 65 DOM - 1,0 kg
o o
Table 2
Table 1
DN
DESCAL NI G
Ca++R
Ca++
ELECTRONIC SCALE CONTROL UNIT
POWER
PO W EL
ANTICA
min. 3 x DNmin. 3 x DN 200 mm
METALPLASTIC
N x N x
Total hardness ( dH) < 16 16 - 24 24 - 32 32 - 40 > 40Num. of coils N + N 11 + 11 12 + 12 13 + 13 14 + 14 15 + 151 dH <=> 0,18 mmol / l <=> 0,36 mval / l <=> 17,8 ppm <=> 1,78 f oo
o
Type of the device Optimum flow rate (m3/h)
Internal diameter of piping (mm-inch)
Dimensions (WxHxD mm)
EUV 10 D 0,10 - 0,45 10 (3/8") 160 x 96 x 61 EUV 15 D 0,30 - 1,00 15 (1/2") 160 x 96 x 61 EUV 20 D 0,60 - 1,80 20 (3/4") 160 x 96 x 61 EUV 25 D 0,90 - 2,70 25 (1") 160 x 96 x 61 EUV 32 D 1,40 - 4,40 32 (5/4") 160 x 96 x 61 EUV 40 D 2,30 - 6,80 40 (6/4") 160 x 96 x 61 EUV 50 D 3,50 - 10,50 50 (2") 160 x 96 x 61 EUV 65 D 6,00 - 18,00 65 (2 1/2") 215 x 130 x 77
SPECIFICATIONS:
Supply voltage: 230 V, 50 Hz (US model 110 V, 60 Hz)Consumption: EUV 10 - 65 D - 6 VAWorking period: min. 20 yearsWorking temp.: 0 C to 40 CWeight: EUV 10 - 50 D - 1,0 kg EUV 65 D - 2,5 kg Signalling contacts: EUV 65 D only max 15 W, max 1 A, max 125 V
o o
Table 2
Table 1
DN
Devices EUV 10 D - 65 DThey are designed for simple applications, if the flow rate is within the limits given in the table 2.In the case, when the flow rate is at the lower limit and any other circumstances do not prevent it, it is recommended to reduce piping diameter in the place of installation and use the device, which is smaller by one order.
These devices are suitable for sm all plants, such as:- laundries- bakeries- small compressor rooms- hairdresser´s and the like
EUV D
Ca ++R
aC ++
ELECTRONIC SCALE ELIMINATOR
POWER
POWEL
ANTICA
0
0
DESCALING
Ca ++R
aC ++
ELECTRONIC SCALE CONTROL UNIT
POWER
POWEL
ANTICA
0
0
DESCALING
13:552001.09.06
Logik
OK
PRG R
1
2
EUV T
min. 3 x DNmin. 3 x DN 200 mm
PLASTIC
N x N x
METAL
Total hardness ( dH) < 16 16 - 24 24 - 32 32 - 40 > 40Num. of coils N + N 11 + 11 12 + 12 13 + 13 14 + 14 15 + 151 dH <=> 0,18 mmol / l <=> 0,36 mval / l <=> 17,8 ppm <=> 1,78 f oo
o
EUV 32 T - 65 T devicesThey are designed for applications , where it is necessary to change treating signal performance in dependence of variable flow rate. The treating signal can be changed in two levels. These devices are supplied with switch timer and are suitable for:- small industrial plants- hotels, motels,- heat exchanger stations
Type of the device Optimum flow rate (m3/h)
Internal diameter of piping (mm-inch)
Dimensions
(WxHxD mm) EUV 32 T I. 0,40 - 1,40
II. 1,40 - 4,40 32 (5/4") 215 x 130 x 77
EUV 40 T I. 0,80 - 2,30 II. 2,30 - 6,80
40 (6/4") 215 x 130 x 77
EUV 50 T I. 1,20 - 3,50 II. 3,50 - 10,50
50 (2") 215 x 130 x 77
EUV 65 T I. 2,00 - 6,00 II. 6,00 - 18,00
65 (2 1/2") 215 x 130 x 77
SPECIFICATIONS:
Supply voltage: 230 V, 50 Hz (US model 110 V, 60 Hz)Consumption: EUV 32 - 65 T - 6 VAWorking cycle: daily or weeklyWorking period: min. 20 yearsWorking temp.: 0 C to 40 CWeight: EUV 32 - 65 T - 2,5 kg Signalling contacts: max 15 W, max 1 A, max 125 V
oo
Table 2
Table 1
DN
LEVEL
Luca
6
DESCALING
POWER
ELECTRONIC SCALE CONTROL UNITPOWE L
ANTICA
+
+
+ +
Ca++R
Ca++R
.
EUV MI
min. 3 x DNmin. 3 x DN L
11 x 11 x
TYPE OF DEVICE L (mm)
EUV 50 MI 200EUV 65 MI 200EUV 80 MI 250EUV 100 MI 250EUV 125 MI 300EUV 150 MI 300EUV 200 MI 500EUV 250 MI 500EUV 300 MI 800EUV 400 MI 800EUV 500 MI 800
EUV 50 MI - 500 MI devices
Typical use: Industrial applications Type of the device Optimum flow rate
(m3/h) Internal diameter of piping (mm-inch)
Dimensions (WxHxD mm)
EUV 50 MI 0,20 - 11 (16)* 50 (2") 275 x 220 x 140 EUV 65 MI 0,30 - 18 (26)* 65 (2 1/2") 275 x 220 x 140 EUV 80 MI 0,50 - 27 (40)* 80 (3") 275 x 220 x 140 EUV 100 MI 0,80 - 42 (62)* 100 (4") 275 x 220 x 140 EUV 125 MI 1,40 - 66 (100)* 125 (5") 275 x 220 x 140 EUV 150 MI 2,00 - 100 (140)* 150 (6") 275 x 220 x 140 EUV 200 MI 3,20 - 170 (250)* 200 (8") 275 x 220 x 140 EUV 250 MI 6,00 - 270 (400)* 250 (10") 275 x 220 x 140 EUV 300 MI 8,00 - 380 (560)* 300 (12") 275 x 220 x 140 EUV 400 MI 13,00 - 680 (1000)* 400 (16") 275 x 370 x 140 EUV 500 MI 24,00 - 1100 (1600)* 500 (20") 275 x 370 x 140
SPECIFICATIONS:Supply voltage: 230 V, 50 Hz (US model 110 V, 60 Hz)Consumption: EUV 50 - 300 MI - 10 VA EUV 400 - 500 MI - 16 VAWorking period: min. 20 yearsWorking temp.: 0 C to 40 CWeight: 4 to 6 kg Signalling contacts: max 15 W, max 1 A, max 125 V
o o
Table 2
Table 1
DN
These devices are most popular - designed for applications, where the water flow changes in great values. Treating signal can be adjusted in 9 levels manually by switching knob - in accordance of the flow rate. Each unit is equipped with a table with specified water flow and treating signal level.
![Page 12: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/12.jpg)
DE CALS ING
Ca++R
Ca++
ELECTRONIC SCALE CONTROL UNITEUV DOM
min. 3 x DNmin. 3 x DN 200 mm
METALPLASTIC
Total hardness ( dH) < 16 16 - 24 24 - 32 32 - 40 > 40Num. of coils N + N 11 + 11 12 + 12 13 + 13 14 + 14 15 + 151 dH <=> 0,18 mmol / l <=> 0,36 mval / l <=> 17,8 ppm <=> 1,78 f oo
o
N x N x
ONLY FOR HOUSEHOLD !
CAUTION!
Devices EUV 15 DOM - 65 DOM
They are designed for simple applications, if the flow rate is within the limits given in the table 2.
In the case, when the flow rate is at the lower limit and any other circumstances do not prevent it, it is recommended to reduce piping diameter in the place of installation and use the device, which is smaller by one order. These devices are suitable for households.
Type of the device
Optimum flow rate
(m3/h)
Internal diameter of
piping (mm-inch)
Dimensions
(WxHxD mm)
EUV 15 DOM
0,1 - 0,3
15 (1/2")
110 x 70 x 55
EUV 20 DOM
0,2 - 0,6
20 (3/4")
110 x 70 x 55
EUV 25 DOM
0,3 - 0,9
25 (1")
110 x 70 x 55
EUV 32 DOM
0,4 - 1,4
32 (5/4")
160 x 96 x 61
EUV 40 DOM
0,8 - 2,3
40 (6/4")
160 x 96 x 61
EUV 50 DOM
1,2 - 3,5
50 (2")
160 x 96 x 61
EUV 65 DOM 2,0 - 6,0 65 (2 1/2") 160 x 96 x 61
SPECIFICATIONS:
Supply voltage: 230 V, 50 Hz (US model 110 V, 60 Hz)Consumption: EUV 15 - 25 DOM - 2 VA EUV 32 - 65 DOM - 6 VAWorking period: min. 20 yearsWorking temp.: 0 C to 40 CWeight: EUV 15 - 25 DOM - 0,5 kg EUV 32 - 65 DOM - 1,0 kg
o o
Table 2
Table 1
DN
DESCALING
Ca++R
Ca++
ELECTRONIC SCALE CONTROL UNIT
POWER
PO W EL
ANTICA
min. 3 x DNmin. 3 x DN 200 mm
METALPLASTIC
N x N x
Total hardness ( dH) < 16 16 - 24 24 - 32 32 - 40 > 40Num. of coils N + N 11 + 11 12 + 12 13 + 13 14 + 14 15 + 151 dH <=> 0,18 mmol / l <=> 0,36 mval / l <=> 17,8 ppm <=> 1,78 f oo
o
Type of the device Optimum flow rate (m3/h)
Internal diameter of piping (mm-inch)
Dimensions (WxHxD mm)
EUV 10 D 0,10 - 0,45 10 (3/8") 160 x 96 x 61 EUV 15 D 0,30 - 1,00 15 (1/2") 160 x 96 x 61 EUV 20 D 0,60 - 1,80 20 (3/4") 160 x 96 x 61 EUV 25 D 0,90 - 2,70 25 (1") 160 x 96 x 61 EUV 32 D 1,40 - 4,40 32 (5/4") 160 x 96 x 61 EUV 40 D 2,30 - 6,80 40 (6/4") 160 x 96 x 61 EUV 50 D 3,50 - 10,50 50 (2") 160 x 96 x 61 EUV 65 D 6,00 - 18,00 65 (2 1/2") 215 x 130 x 77
SPECIFICATIONS:
Supply voltage: 230 V, 50 Hz (US model 110 V, 60 Hz)Consumption: EUV 10 - 65 D - 6 VAWorking period: min. 20 yearsWorking temp.: 0 C to 40 CWeight: EUV 10 - 50 D - 1,0 kg EUV 65 D - 2,5 kg Signalling contacts: EUV 65 D only max 15 W, max 1 A, max 125 V
o o
Table 2
Table 1
DN
Devices EUV 10 D - 65 DThey are designed for simple applications, if the flow rate is within the limits given in the table 2.In the case, when the flow rate is at the lower limit and any other circumstances do not prevent it, it is recommended to reduce piping diameter in the place of installation and use the device, which is smaller by one order.
These devices are suitable for sm all plants, such as:- laundries- bakeries- small compressor rooms- hairdresser´s and the like
EUV D
Ca ++R
Ca++
ELECTRONIC SCALE ELIMINATOR
POW RE
POWEL
ANTICA
0
0
DESCALING
Ca ++R
Ca++
ELECTRONIC SCALE CONTROL UNIT
POW RE
POWEL
ANTICA
0
0
DESCALING
13:552001.09.06
Logik
OK
PRG R
1
2
EUV T
min. 3 x DNmin. 3 x DN 200 mm
PLASTIC
N x N x
METAL
Total hardness ( dH) < 16 16 - 24 24 - 32 32 - 40 > 40Num. of coils N + N 11 + 11 12 + 12 13 + 13 14 + 14 15 + 151 dH <=> 0,18 mmol / l <=> 0,36 mval / l <=> 17,8 ppm <=> 1,78 f oo
o
EUV 32 T - 65 T devicesThey are designed for applications , where it is necessary to change treating signal performance in dependence of variable flow rate. The treating signal can be changed in two levels. These devices are supplied with switch timer and are suitable for:- small industrial plants- hotels, motels,- heat exchanger stations
Type of the device Optimum flow rate (m3/h)
Internal diameter of piping (mm-inch)
Dimensions
(WxHxD mm) EUV 32 T I. 0,40 - 1,40
II. 1,40 - 4,40 32 (5/4") 215 x 130 x 77
EUV 40 T I. 0,80 - 2,30 II. 2,30 - 6,80
40 (6/4") 215 x 130 x 77
EUV 50 T I. 1,20 - 3,50 II. 3,50 - 10,50
50 (2") 215 x 130 x 77
EUV 65 T I. 2,00 - 6,00 II. 6,00 - 18,00
65 (2 1/2") 215 x 130 x 77
SPECIFICATIONS:
Supply voltage: 230 V, 50 Hz (US model 110 V, 60 Hz)Consumption: EUV 32 - 65 T - 6 VAWorking cycle: daily or weeklyWorking period: min. 20 yearsWorking temp.: 0 C to 40 CWeight: EUV 32 - 65 T - 2,5 kg Signalling contacts: max 15 W, max 1 A, max 125 V
oo
Table 2
Table 1
DN
LEVEL
Luca
6
DESCALING
POWER
ELECTRONIC SCALE CONTROL UNITPOWE L
ANTICA
+
+
+ +
Ca++R
Ca++R
.
EUV MI
min. 3 x DNmin. 3 x DN L
11 x 11 x
TYPE OF DEVICE L (mm)
EUV 50 MI 200EUV 65 MI 200EUV 80 MI 250EUV 100 MI 250EUV 125 MI 300EUV 150 MI 300EUV 200 MI 500EUV 250 MI 500EUV 300 MI 800EUV 400 MI 800EUV 500 MI 800
EUV 50 MI - 500 MI devices
Typical use: Industrial applications Type of the device Optimum flow rate
(m3/h) Internal diameter of piping (mm-inch)
Dimensions (WxHxD mm)
EUV 50 MI 0,20 - 11 (16)* 50 (2") 275 x 220 x 140 EUV 65 MI 0,30 - 18 (26)* 65 (2 1/2") 275 x 220 x 140 EUV 80 MI 0,50 - 27 (40)* 80 (3") 275 x 220 x 140 EUV 100 MI 0,80 - 42 (62)* 100 (4") 275 x 220 x 140 EUV 125 MI 1,40 - 66 (100)* 125 (5") 275 x 220 x 140 EUV 150 MI 2,00 - 100 (140)* 150 (6") 275 x 220 x 140 EUV 200 MI 3,20 - 170 (250)* 200 (8") 275 x 220 x 140 EUV 250 MI 6,00 - 270 (400)* 250 (10") 275 x 220 x 140 EUV 300 MI 8,00 - 380 (560)* 300 (12") 275 x 220 x 140 EUV 400 MI 13,00 - 680 (1000)* 400 (16") 275 x 370 x 140 EUV 500 MI 24,00 - 1100 (1600)* 500 (20") 275 x 370 x 140
SPECIFICATIONS:Supply voltage: 230 V, 50 Hz (US model 110 V, 60 Hz)Consumption: EUV 50 - 300 MI - 10 VA EUV 400 - 500 MI - 16 VAWorking period: min. 20 yearsWorking temp.: 0 C to 40 CWeight: 4 to 6 kg Signalling contacts: max 15 W, max 1 A, max 125 V
o o
Table 2
Table 1
DN
These devices are most popular - designed for applications, where the water flow changes in great values. Treating signal can be adjusted in 9 levels manually by switching knob - in accordance of the flow rate. Each unit is equipped with a table with specified water flow and treating signal level.
![Page 13: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/13.jpg)
LEVEL
Luca
6
DESCALING
POWER
ELECTRONIC SCALE CONTROL UNITPO WE L
ANTICA
+
+
+ +
Ca++R
Ca++R
.
8
EUV TI
13:552001.09.06
Logik
OK
PRG R
1
2
min. 3 x DNmin. 3 x DN L
11 x 11 x
TYPE OF DEVICE L (mm)
EUV 50 TI 200EUV 65 TI 200EUV 80 TI 250EUV 100 TI 250EUV 125 TI 300EUV 150 TI 300EUV 200 TI 500EUV 250 TI 500EUV 300 TI 800EUV 400 TI 800EUV 500 TI 800
EUV 50TI - 500 TI devicesThese devices are designed for similar applications like types EUV MI. The 9 levels can be still
devided in two time zones. (The setting is independent in both zones in the extent as for MI).
Typical use: industrial applications.
SPECIFICATIONS:Supply voltage: 230 V, 50 Hz (US model 110 V, 60 Hz)Consumption: EUV 50 - 300 TI - 10 VA EUV 400 - 500 TI - 16 VAWorking cycle: daily or weeklyWorking temp.: 0 C to 40 CWeight: 4 to 6 kg Signalling contacts: max 15 W, max 1 A, max 125 V
o o
Type of the device Optimum flow rate (m3/h)
Internal diameter of piping (mm-inch)
Dimensions
(WxHxD mm)
EUV 50 TI 0,20 - 11 (16)* 50 (2") 275 x 220 x 140 EUV 65 TI 0,30 - 18 (26)* 65 (2 1/2") 275 x 220 x 140 EUV 80 TI 0,50 - 27 (40)* 80 (3") 275 x 220 x 140 EUV 100 TI 0,80 - 42 (62)* 100 (4") 275 x 220 x 140 EUV 125 TI 1,40 - 66 (100)* 125 (5") 275 x 220 x 140 EUV 150 TI 2,00 - 100 (140)* 150 (6") 275 x 220 x 140 EUV 200 TI 3,20 - 170 (250)* 200 (8") 275 x 220 x 140 EUV 250 TI 6,00 - 270 (400)* 250 (10") 275 x 220 x 140 EUV 300 TI 8,00 - 380 (560)* 300 (12") 275 x 220 x 140 EUV 400 TI 13,00 - 680 (1000)* 400 (16") 275 x 370 x 140 EUV 500 TI 24,00 - 1100 (1600)* 500 (20") 275 x 370 x 140
Table 2
Table 1
DN
LEVEL
Luca
DESCALING
POWER
ELECTRONIC SCALE CONTROL UNITPOW EL
ANTICA
+
+
+ +
Ca++R
Ca++R
.
8
A M
0
000 394
EUV AI
min. 3 x DNmin. 3 x DN L
11 x 11 x
TYPE OF DEVICE L (mm)
EUV 50 AI 200EUV 65 AI 200EUV 80 AI 250EUV 100 AI 250EUV 125 AI 300EUV 150 AI 300EUV 200 AI 500EUV 250 AI 500EUV 300 AI 800EUV 400 AI 800EUV 500 AI 800
OPTOSENSOR
FLOWMETER
EUV 50 AI - 500 AI devicesThese devices are designed for the same applications like types EUV MI. The treating signal is adjusted automatically according real flow rate . The device must be connected to a flowmeter, which is equipped with a sensor, which gives information about flow rate to device´s control unit.
(The flowmeter and sensor must be ordered separately, as they are not supplied with the device)
Typical use: large water treatment plants, boiler rooms, heat exchangers etc.
SPECIFICATIONS:Supply voltage: 230 V, 50 Hz (US model 110 V, 60 Hz)Consumption: EUV 50 - 300 AI - 10 VA EUV 400 - 500 AI - 16 VAImp. contr. signal: 1 l/1imp., 10 l/1imp.Working temp.: 0 C to 40 CWeight: 4 to 6 kg Signalling contacts: max 15 W, max 1 A, max 125 V
o o
Type of the device Optimum flow rate (m3/h)
Internal diameter of piping (mm-inch)
Dimensions
(WxHxD mm) EUV 50 AI 0,20 - 11 (16)* 50 (2") 275 x 220 x 140 EUV 65 AI 0,30 - 18 (26)* 65 (2 1/2") 275 x 220 x 140 EUV 80 AI 0,50 - 27 (40)* 80 (3") 275 x 220 x 140 EUV 100 AI 0,80 - 42 (62)* 100 (4") 275 x 220 x 140 EUV 125 AI 1,40 - 66 (100)* 125 (5") 275 x 220 x 140 EUV 150 AI 2,00 - 100 (140)* 150 (6") 275 x 220 x 140 EUV 200 AI 3,20 - 170 (250)* 200 (8") 275 x 220 x 140 EUV 250 AI 6,00 - 270 (400)* 250 (10") 275 x 220 x 140 EUV 300 AI 8,00 - 380 (560)* 300 (12") 275 x 220 x 140 EUV 400 AI 13,00 - 680 (1000)* 400 (16") 275 x 370 x 140 EUV 500 AI 24,00 - 1100 (1600)* 500 (20") 275 x 370 x 140
Table 2
Table 1
DN
![Page 14: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/14.jpg)
LEVEL
Luca
6
DESCALING
POWER
ELECTRONIC SCALE CONTROL UNITPO WE L
ANTICA
+
+
+ +
Ca++R
Ca++R
.
8
EUV TI
13:552001.09.06
Logik
OK
PRG R
1
2
min. 3 x DNmin. 3 x DN L
11 x 11 x
TYPE OF DEVICE L (mm)
EUV 50 TI 200EUV 65 TI 200EUV 80 TI 250EUV 100 TI 250EUV 125 TI 300EUV 150 TI 300EUV 200 TI 500EUV 250 TI 500EUV 300 TI 800EUV 400 TI 800EUV 500 TI 800
EUV 50TI - 500 TI devicesThese devices are designed for similar applications like types EUV MI. The 9 levels can be still
devided in two time zones. (The setting is independent in both zones in the extent as for MI).
Typical use: industrial applications.
SPECIFICATIONS:Supply voltage: 230 V, 50 Hz (US model 110 V, 60 Hz)Consumption: EUV 50 - 300 TI - 10 VA EUV 400 - 500 TI - 16 VAWorking cycle: daily or weeklyWorking temp.: 0 C to 40 CWeight: 4 to 6 kg Signalling contacts: max 15 W, max 1 A, max 125 V
o o
Type of the device Optimum flow rate (m3/h)
Internal diameter of piping (mm-inch)
Dimensions
(WxHxD mm)
EUV 50 TI 0,20 - 11 (16)* 50 (2") 275 x 220 x 140 EUV 65 TI 0,30 - 18 (26)* 65 (2 1/2") 275 x 220 x 140 EUV 80 TI 0,50 - 27 (40)* 80 (3") 275 x 220 x 140 EUV 100 TI 0,80 - 42 (62)* 100 (4") 275 x 220 x 140 EUV 125 TI 1,40 - 66 (100)* 125 (5") 275 x 220 x 140 EUV 150 TI 2,00 - 100 (140)* 150 (6") 275 x 220 x 140 EUV 200 TI 3,20 - 170 (250)* 200 (8") 275 x 220 x 140 EUV 250 TI 6,00 - 270 (400)* 250 (10") 275 x 220 x 140 EUV 300 TI 8,00 - 380 (560)* 300 (12") 275 x 220 x 140 EUV 400 TI 13,00 - 680 (1000)* 400 (16") 275 x 370 x 140 EUV 500 TI 24,00 - 1100 (1600)* 500 (20") 275 x 370 x 140
Table 2
Table 1
DN
LEVEL
Luca
DESCALING
POWER
ELECTRONIC SCALE CONTROL UNITPOW EL
ANTICA
+
+
+ +
Ca++R
Ca++R
.
8
A M
0
000 394
EUV AI
min. 3 x DNmin. 3 x DN L
11 x 11 x
TYPE OF DEVICE L (mm)
EUV 50 AI 200EUV 65 AI 200EUV 80 AI 250EUV 100 AI 250EUV 125 AI 300EUV 150 AI 300EUV 200 AI 500EUV 250 AI 500EUV 300 AI 800EUV 400 AI 800EUV 500 AI 800
OPTOSENSOR
FLOWMETER
EUV 50 AI - 500 AI devicesThese devices are designed for the same applications like types EUV MI. The treating signal is adjusted automatically according real flow rate . The device must be connected to a flowmeter, which is equipped with a sensor, which gives information about flow rate to device´s control unit.
(The flowmeter and sensor must be ordered separately, as they are not supplied with the device)
Typical use: large water treatment plants, boiler rooms, heat exchangers etc.
SPECIFICATIONS:Supply voltage: 230 V, 50 Hz (US model 110 V, 60 Hz)Consumption: EUV 50 - 300 AI - 10 VA EUV 400 - 500 AI - 16 VAImp. contr. signal: 1 l/1imp., 10 l/1imp.Working temp.: 0 C to 40 CWeight: 4 to 6 kg Signalling contacts: max 15 W, max 1 A, max 125 V
o o
Type of the device Optimum flow rate (m3/h)
Internal diameter of piping (mm-inch)
Dimensions
(WxHxD mm) EUV 50 AI 0,20 - 11 (16)* 50 (2") 275 x 220 x 140 EUV 65 AI 0,30 - 18 (26)* 65 (2 1/2") 275 x 220 x 140 EUV 80 AI 0,50 - 27 (40)* 80 (3") 275 x 220 x 140 EUV 100 AI 0,80 - 42 (62)* 100 (4") 275 x 220 x 140 EUV 125 AI 1,40 - 66 (100)* 125 (5") 275 x 220 x 140 EUV 150 AI 2,00 - 100 (140)* 150 (6") 275 x 220 x 140 EUV 200 AI 3,20 - 170 (250)* 200 (8") 275 x 220 x 140 EUV 250 AI 6,00 - 270 (400)* 250 (10") 275 x 220 x 140 EUV 300 AI 8,00 - 380 (560)* 300 (12") 275 x 220 x 140 EUV 400 AI 13,00 - 680 (1000)* 400 (16") 275 x 370 x 140 EUV 500 AI 24,00 - 1100 (1600)* 500 (20") 275 x 370 x 140
Table 2
Table 1
DN
![Page 15: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/15.jpg)
water international
![Page 16: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/16.jpg)
water international
![Page 17: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/17.jpg)
![Page 18: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/18.jpg)
![Page 19: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/19.jpg)
![Page 20: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/20.jpg)
![Page 21: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/21.jpg)
![Page 22: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/22.jpg)
![Page 23: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/23.jpg)
![Page 24: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/24.jpg)
![Page 25: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/25.jpg)
![Page 26: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/26.jpg)
![Page 27: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/27.jpg)
![Page 28: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/28.jpg)
![Page 29: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/29.jpg)
![Page 30: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/30.jpg)
![Page 31: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/31.jpg)
![Page 32: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/32.jpg)
![Page 33: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/33.jpg)
![Page 34: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/34.jpg)
![Page 35: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/35.jpg)
![Page 36: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/36.jpg)
![Page 37: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/37.jpg)
![Page 38: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/38.jpg)
![Page 39: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/39.jpg)
![Page 40: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/40.jpg)
![Page 41: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/41.jpg)
![Page 42: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/42.jpg)
![Page 43: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/43.jpg)
![Page 44: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/44.jpg)
![Page 45: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/45.jpg)
![Page 46: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/46.jpg)
![Page 47: val-antica-ca-water-treatment](https://reader034.fdocuments.us/reader034/viewer/2022052702/568bd62c1a28ab20349b2057/html5/thumbnails/47.jpg)