VADA - V110-H · 304) stainless steel shim ring Diffusors Technopolymer Shaft X12 CrNiS 1809 (AISI...

6
Disclaimer: Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. Dimensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors. CONSTRUCTION Pump Casing X5 CrNi 1810 (AISI 304) stainless steel Motor Bracket Die-cast aluminium Impeller Technopolymer with X5 CrNi 1810 (AISI 304) stainless steel shim ring Diffusors Technopolymer Shaft X12 CrNiS 1809 (AISI 416) stainless steel Mechanical Seal Graphite Counterface Ceramic Seal Holder Plate GFN2V Noryl O-ring NBR 70 Shore PRODUCT OVERVIEW The VADA horizontal multistage centrifugal pumps combine the functional benefits of centrifugal pumps and the practical benefits of self priming pumps. They warrant high hydraulic and suction performances. USAGE LIMITATIONS Type of liquid: clean water with no suspended solids or abrasive material Maximum liquid temperature: 50 O C Maximum/Minimum ambient temperature: 40 O C / 5 O C Maximum recommended suction height: 7m with foot valve Maximum operating pressure: 7 bar VADA - V110-H MOTOR Enclosed, externally ventilated Level of protection IP44 Class F insulation Single phase power supply with capacitor permanently acti- vated and thermal protection built into the motor winding Thermal protection built into the motor winding Speed of rotation 2850 rpm Suitable for continuous use WARRANTY You have purchased a quality product from Reece Australia. This product is covered by a 24 month warranty. This warranty covers faults in the product construction, material and assembly. Faulty products will be repaired or exchanged free of charge. Faulty items become our property. This warranty does not include faults caused by Unsuitable or improper use Incorrect installation Normal wear and tear Inadequate or complete lack of maintenance Chemical, electrochemical or electrical influences To the maximum extent permitted by law, Reece excludes all warranties other than those set out above. In the event of a warranty claim, we will replace or repair defective products, or pay for the cost of having defective products repaired or replaced, but will not be liable for any injury to any person, damage to any property, any indirect or consequential loss, or in any other respect.

Transcript of VADA - V110-H · 304) stainless steel shim ring Diffusors Technopolymer Shaft X12 CrNiS 1809 (AISI...

Page 1: VADA - V110-H · 304) stainless steel shim ring Diffusors Technopolymer Shaft X12 CrNiS 1809 (AISI 416) stainless steel Mechanical Seal Graphite Counterface Ceramic Seal Holder Plate

Disclaimer:Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributorreserves the right to vary specifications or delete models from their range without prior notification. Dimensions and set-outs listed arecorrect at time of publication however the manufacturer/distributor takes no responsibility for printing errors.

CONSTRUCTIONPump Casing X5 CrNi 1810 (AISI 304) stainless steel

Motor Bracket Die-cast aluminium

Impeller Technopolymer with X5 CrNi 1810 (AISI 304) stainless steel shim ring

Diffusors Technopolymer

Shaft X12 CrNiS 1809 (AISI 416) stainless steel

Mechanical Seal Graphite

Counterface Ceramic

Seal Holder Plate GFN2V Noryl

O-ring NBR 70 Shore

PRODUCT OVERVIEWThe VADA horizontal multistage centrifugal pumps combine the functional benefits of centrifugal pumps and the practical benefits of self priming pumps. They warrant high hydraulic and suction performances.

USAGE LIMITATIONS• Type of liquid: clean water with no suspended solids or abrasive

material• Maximum liquid temperature: 50OC• Maximum/Minimum ambient temperature: 40OC / 5OC• Maximum recommended suction height: 7m with foot valve• Maximum operating pressure: 7 bar

VADA - V110-H

MOTOR• Enclosed, externally ventilated• Level of protection IP44• Class F insulation• Single phase power supply with capacitor permanently acti-

vated and thermal protection built into the motor winding• Thermal protection built into the motor winding• Speed of rotation 2850 rpm• Suitable for continuous use

WARRANTYYou have purchased a quality product from Reece Australia. This product is covered by a 24 month warranty. This warranty covers faults in the product construction, material and assembly. Faulty products will be repaired or exchanged free of charge. Faulty items become our property.This warranty does not include faults caused by• Unsuitable or improper use• Incorrect installation• Normal wear and tear• Inadequate or complete lack of maintenance• Chemical, electrochemical or electrical influences

To the maximum extent permitted by law, Reece excludes all warranties other than those set out above. In the event of a warranty claim, we will replace or repair defective products, or pay for the cost of having defective products repaired or replaced, but will not be liable for any injury to any person, damage to any property, any indirect or consequential loss, or in any other respect.

Page 2: VADA - V110-H · 304) stainless steel shim ring Diffusors Technopolymer Shaft X12 CrNiS 1809 (AISI 416) stainless steel Mechanical Seal Graphite Counterface Ceramic Seal Holder Plate

Disclaimer:Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributorreserves the right to vary specifications or delete models from their range without prior notification. Dimensions and set-outs listed arecorrect at time of publication however the manufacturer/distributor takes no responsibility for printing errors.

TABLE OF HYDRAULIC PERFORMANCE

PUMP PERFORMANCE

PUMP DIMENSIONS

Q

Hm

L / 1'm3/ h

20

1,2

20

40

2,4

60

3,6

80

4,8

10

30

40

50

60

120

7,2

100

6

V110-H

ModelNominal power Absorbed

power Voltage Amp µF QL/1’ 0 20 40 60 80 100

HP kW HP kW m3/h 1.2 2.4 3.6 4.8 6

V110-H 1.2 0.9 1.7 1.25 1~230V 5.8 20 Discharge head in meters 60 55 48 36 26 10

ModelDimensions (mm) Weight

A B C D Suction Port Outlet Port kg

V110-H 129 392 182 176 1” F 1” F 11

B

D

SU

CTI

ON

PO

RT

OUTLET PORT

A

C

VADA - V110-H

Page 3: VADA - V110-H · 304) stainless steel shim ring Diffusors Technopolymer Shaft X12 CrNiS 1809 (AISI 416) stainless steel Mechanical Seal Graphite Counterface Ceramic Seal Holder Plate

Disclaimer:Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributorreserves the right to vary specifications or delete models from their range without prior notification. Dimensions and set-outs listed arecorrect at time of publication however the manufacturer/distributor takes no responsibility for printing errors.

PREPARING FOR INSTALLATIONInspect your pump, ensuring that it is well packaged and has not been damaged in transport. If the pump is damaged, report it to the Reece branch where the pump was purchased. Make sure the suction piping is completely air tight and is laid so that there can be no air locks. Warranty of these pumps is void unless they are operated in accordance with these instructions.

PUMP PROTECTIONThe pump should be protected from the weather, floods, chemicals, dust, vermin and insects. It is recommended that the pump be housed in a weather proof, well vented enclosure.

The pump is designed to be used with clean water in a residential application. Do not use it with alternative fluids, specifically abrasive, corrosive or explosive fluids. Do not install or operate your pump in an explosive environment or near combustible matter.

Incorrectly installed or tested equipment may fail, causing severe injury or property damage.

Fire and burn hazard. Modern motors run at high temperatures. To reduce risk of fire, do not allow leaves, debris, or foreign matter to collect around the pump motor. To avoid burns when handling the motor, let it cool for at least 20 minutes before trying to work on it. A thermal overload switch protects the motor from heat damage during operation.

Only qualified, licensed personnel should install pump. The electrical installation shall be in accordance with the national wiring rules (AS/NZS 3000) for class 1, IP44 rated products.

These instructions are a guide only. Users not familiar with pumping equipment should seek advice from people experienced in pump equipment and installation.

Freezing conditions will damage the unit, because when water freezes it expands. Ensure that the pump is located so that it is not prone to freezing, or ensure that the product is disconnected and dried of water during cold conditions.

The pump is electrically connected. Ensure that it is isolated from electrical supply during installation and any subsequent service work.

INSTALLATIONPlease pay careful attention to the following warnings signs and indications.

VADA - V110-H

Page 4: VADA - V110-H · 304) stainless steel shim ring Diffusors Technopolymer Shaft X12 CrNiS 1809 (AISI 416) stainless steel Mechanical Seal Graphite Counterface Ceramic Seal Holder Plate

Disclaimer:Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributorreserves the right to vary specifications or delete models from their range without prior notification. Dimensions and set-outs listed arecorrect at time of publication however the manufacturer/distributor takes no responsibility for printing errors.

GENERAL INSTALLATION1. Fitting and Auto Pressure Control or Mains Water Switch Over DeviceIf you are using a Vada Auto Pressure Control or a Mains Water Switch Over Device with your pump, connect it either directly to the top of the pump or in a suitable position in line with the delivery piping. For further instructions on connecting these devices, please refer to the manual supplied with your unit. Ensure that the power lead remains disconnected until you have completed the installation process.

2. Locating the PumpFind a location for your pump as close to your water source as possible. Ensure that this location is stable, dry and on a separate footing from your home. To do this you can mount the pump on a concrete base.

3. Power SourceArrange for an electrician to install a 10A weatherproof outdoor power point near the pump if there is not one there already.

4. SuctionThis is the most important part of the installation as errors will cause significant problems for the system in performance and longevity.A gate valve must be installed at the water source outlet. To maintain optimum performance from your pump, the suction pipe should be:

• Kept to the shortest length practical.• Re-enforced crush resistant (non-collapsible) hose or pipe.• All fittings should be air tight.• Pipes should be equal to or larger than the diameter of the suction/inlet port.• When pumping from a well/pit etc. a foot valve should be installed on the suction pipe.• Optional: Fitted with a suction Strainer/Filter*

*In-line strainers/filters are only recommended for pumps fitted with a Vada Auto Pressure Control or a Mains Water Switch Over Device. Regular maintenance is required to keep them clean and provide maximum pump pressure.

5. DischargeThe length and diameter of the discharge hoses/pipes will affect the pressure and flow rate at which your pump operates. Pressure ratings of all components must exceed the maximum pressure of the pump by an appropriate safety factor. All pipe work should be supported independently of the pump.

If you want to test that the pump is operating correctly prior to having the plumbing connected, attach a hose with a trigger nozzle to the top of the pump or the connected discharge hoses/pipes.

6. Pump PrimingEnsure that there is at least 200mm of water in your tank, (i.e. that the tank outlet is covered, and the pump will not draw any air into the system). Open the gate valve on the water source. Check for any leaks, and repair these if necessary.

• If no leaks are present, remove the priming plug to open the priming port on the top of the pump case. If the tank is above the level of the pump, water will start to run out of this port. Replace the priming plug carefully. Your pump is not ready to run.

• If the tank water level is below the level of the pump, you will need to fill the pump body and suction line. Remove the priming plug and fill the pump body and suction line using a funnel.

VADA - V110-H

Page 5: VADA - V110-H · 304) stainless steel shim ring Diffusors Technopolymer Shaft X12 CrNiS 1809 (AISI 416) stainless steel Mechanical Seal Graphite Counterface Ceramic Seal Holder Plate

Disclaimer:Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributorreserves the right to vary specifications or delete models from their range without prior notification. Dimensions and set-outs listed arecorrect at time of publication however the manufacturer/distributor takes no responsibility for printing errors.

Fire and burn hazard. Modern motors run at high temperatures. To reduce risk of fire, do not allow leaves, debris, or foreign matter to collect around the pump motor. To avoid burns when handling the motor, let it cool for at least 20 minutes before trying to work on it. A thermal overload switch pro-tects the motor for heat damage during operation.

DO NOT RUN PUMP DRYEnsure that your pump is primed before operating

The pump operator or owner must be provided with this owner’s manual. This must be read before operation, and followed during operation.

Ensure that your pump is filled with water before operating.

The pump is designed to be used with clean water in a residential application. Do not use it with alternative fluids, specifically abrasive, corrosive or explosive fluids. Do not install or operate your pump in an explosive enviroment or near combustible matter.

OPERATION

START-UP/OPERATIONOpen all valves in the suction and discharge lines. When the power is turned on, the pump will start to pump water. Without an Auto Pressure Control or Mains Water Switch-Over Device, the pump will continue to operate until the power is switched off.

Most applications will incorporate an Auto Pressure Control or Mains Water Switch-Over Device which will stop the pump as soon as it has pressurised the system it is connected to. For instructions on operating your pump with one of these devices, please refer to the manual that came with your unit.

The system is now ready for use. If no water is delivered, check the troubleshooting section.

VADA - V110-H

ELECTRICAL INSTALLATION

In accordance with AS 3350.2.41 we are obliged to inform you that this pump is not to be used by children or infirm persons and must not be used as a toy by children

The pump must be supplied by an outlet protected by a residual current device or earth leakage circuit breaker with a maximum rated residual current of 30mA

The pump is supplied with:• A fixed cable featuring a weatherproof IEC socket• A separate power cable which features a weatherproof IEC plug and a standard Australian 10 amp plug.

If connecting directly to a power outlet, simply connect the two supplied cords using the IEC socket and plug. If you are installing a Vada Auto Pressure Control or a Mains Water Switch Over Device, connect the IEC socket from the pump to the IEC plug cord on the device.

Ensuring there are no water traces on the connectors push them firmly into each other to ensure intended splash (water) proof protection. This connection shall be separated again only for service purpose and only after the power supply is removed by unplugging the cord form the socket outlet. The socket outlet shall be in dry and flood free location; preferably do not use extension cords for this very reason and because they can cause voltage drop. Supply voltage outside limits specified in Model Data can cause motor overheat leading to overload tripping, reduced component life or seriously damage pump and voids warranty.

For additional protection, the pump must be supplied from an outlet protected by a residual current device – RCD (also known as an Electrical Leakage Circuit breaker – ELCB) with a maximum rated residual current of 30mA.

Page 6: VADA - V110-H · 304) stainless steel shim ring Diffusors Technopolymer Shaft X12 CrNiS 1809 (AISI 416) stainless steel Mechanical Seal Graphite Counterface Ceramic Seal Holder Plate

Disclaimer:Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributorreserves the right to vary specifications or delete models from their range without prior notification. Dimensions and set-outs listed arecorrect at time of publication however the manufacturer/distributor takes no responsibility for printing errors.

TROUBLE SHOOTING GUIDE

Symptom Cause Remedy

The motor will not start, no water is pumped No electricity Ensure that the pump is connected to a live outlet

Motor protection tripped Verify the cause and reset the switch. If the thermal circuit breaker has tripped wait for the system to cool down

Defective condenser Replace the condenser

Shaft blocked Verify the cause and unblock the pump

The motor runs but no water is pumped The pump is sucking air Makes sure that the joints are airtight

Check that the level of liquid has not dropped below the minimum priming level.

The pump rotates in the wrong direction Reset the direction of rotation

The pump stops after running for a short pe-riod of time because the thermal motor circuit breaker trips

The power supply does not conform with the data on the nameplate

Check the voltage on the power supply cable leads

A solid object is blocking the impellers Call 1800 032 566 for your nearest Reece branch

The liquid is too thick Call 1800 032 566 for your nearest Reece branch. You may need a different type of pump

VADA - V110-H

Liquid may be HOT, release pressure with care before servicing.

Pump should only be serviced by qualified personel. For best results, use only genuine service parts. Be sure to prime pump before starting.

To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor and remove plug from power outlet before working on pump or motor.

SERVICE AND MAINTENANCE

GENERAL CARE AND MAINTENANCEUnder normal conditions VADA pumps do not need any type of maintenance. In order to avoid possible failures, it is advisable to periodically check the pressure supplied and current absorption. A decrease in pressure is a symptom of wear. An increase in current absorption is a sign of abnormal mechanical friction in the pump and/or motor.

If the pump is not going to be used for long periods of time it should be emptied completely, rinsed with clean water and put in a dry place.