Vacuum Pad Holder Only - PISCO · For specific pad(※3) Slim No cover B-E Screwed type Side port...
Transcript of Vacuum Pad Holder Only - PISCO · For specific pad(※3) Slim No cover B-E Screwed type Side port...
1116
https://en.pisco.co.jp/
Suitable holder type for your application is available.Suitable holder type for your application is available.
Vacuum Pad Holder Only
■■ Fixed type and Spring type are available.Fixed type:12 types. Spring type:11 types
■■ Joint type can be selected from Push-in fitting, Barb fitting, Female thread and Male thread.Push-in fitting size:8 sizes. Barb fitting size:3 sizes.
Female thread size:5 sizes. Male thread :9 sizes.
■■ Variety of selections in pad holder for "Copper alloy free" and against "low ozone concentration"and against "low ozone concentration"
-S3 spec.:No copper based metal parts. HNBR or FKM is adopted for seal rubber.
■■Wide selection of holder typeHolder type:23 types
■■ Model code for pad holder alone is now simplified and easily understandable.Connectable pad holder can be selected easily by connection configuration code listed in "Combination list of pad holder and pad" on page 1117.
1117
Vacuum Pad SeriesVacuum Pad Holder Only
A B FC DFixed typeTop port
Fixed typeSide port
Spring typeTop port
Spring typeSide port
Spring typeDirect mount
HCSpring type
Top port
HDSpring typeSide port
HDWSpring type
Dual side port
HEFixed type
Direct mountSide port
HEWFixed type
Direct mountDual side port
EFixed type
Direct mount
Standard
Mini
For specific pad(※1)
Standard
Mini
For specific pad
Standard
Mini
For specific pad
StandardNo cover No cover
Mini
For specific pad
Standard
Mini
For specific pad(※1)
Standard
Mini
For specific pad
Standard
Mini
For specific pad(※2)
Standard
Mini
For specific pad(※2)
Standard
Mini
For specific pad(※2)
Standard
Mini
For specific pad(※2)
Standard
Mini
For specific pad(※2)
Slim Slim Slim Slim Slim Slim Slim Slim Slim Slim Slim
No cover No cover No cover No cover No cover No cover No cover No cover No cover
A-EScrewed type
Top port
Standard
Mini
For specific pad(※3)
Slim
No cover
B-EScrewed type
Side port
Standard
Mini
For specific pad(※3)
Slim
No cover
-PB15-E20-E10-M4 -M6-M10 -M20
-T8-T15 -T40
-H3 -T4
Connection
configuration
drawing
Connection typeInsert type
(Direct connection)Mount type
(Direct connection)Screw type
(Connection with screw)
※Special padscrews, etc is required for -M□
Mount type(Direct connection)
Mount type(Direct connection)
Connection
configuration
code
Pad type
Standard Soft Soft Bellows Skidproof Bellows Multi-bellows
For packaging bag Ultrathin Flat Mark-free SpongeGeneral Deep Small
Code R A RM L LB K B W PB P F Q SPad size (øm
m)
0.7 ○1 ○ ○
1.5 ○2 ○ ○3 ○ ○4 ○ ○ ○6 ○ ○ ○ ○8 ○ ○ ○ ○ ○
10 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○15 ○ ○ ○ ○ ○ ○ ○ ○20 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○25 ○ ○ ○ ○ ○30 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○35 ○40 ○ ○ ○ ○ ○ ○ ○50 ○ ○ ○ ○ ○ ○ ○60 ○ ○ ○70 ○80 ○ ○ ○100 ○ ○ ○ ○150 ○200 ○
-T4-H3
-T8 -T8
-M4 -M4
-M6 -M6
-M10 -M10
-M20
-T15
-T40
■ Combination list of pad holder and pad
1118
https://en.pisco.co.jp/
A B FC DFixed typeTop port
Fixed typeSide port
Spring typeTop port
Spring typeSide port
Spring typeDirect mount
HCSpring type
Top port
HDSpring typeSide port
HDWSpring type
Dual side port
HEFixed type
Direct mountSide port
HEWFixed type
Direct mountDual side port
EFixed type
Direct mount
Standard
Mini
For specific pad(※1)
Standard
Mini
For specific pad
Standard
Mini
For specific pad
StandardNo cover No cover
Mini
For specific pad
Standard
Mini
For specific pad(※1)
Standard
Mini
For specific pad
Standard
Mini
For specific pad(※2)
Standard
Mini
For specific pad(※2)
Standard
Mini
For specific pad(※2)
Standard
Mini
For specific pad(※2)
Standard
Mini
For specific pad(※2)
Slim Slim Slim Slim Slim Slim Slim Slim Slim Slim Slim
No cover No cover No cover No cover No cover No cover No cover No cover No cover
A-EScrewed type
Top port
Standard
Mini
For specific pad(※3)
Slim
No cover
B-EScrewed type
Side port
Standard
Mini
For specific pad(※3)
Slim
No cover
-PB15-E20-E10-M4 -M6-M10 -M20
-T8-T15 -T40
-H3 -T4
Connection
configuration
drawing
Connection typeInsert type
(Direct connection)Mount type
(Direct connection)Screw type
(Connection with screw)
※Special padscrews, etc is required for -M□
Mount type(Direct connection)
Mount type(Direct connection)
Connection
configuration
code
Pad type
Standard Soft Soft Bellows Skidproof Bellows Multi-bellows
For packaging bag Ultrathin Flat Mark-free SpongeGeneral Deep Small
Code R A RM L LB K B W PB P F Q S
Pad size (ømm
)
0.7 ○1 ○ ○
1.5 ○2 ○ ○3 ○ ○4 ○ ○ ○6 ○ ○ ○ ○8 ○ ○ ○ ○ ○
10 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○15 ○ ○ ○ ○ ○ ○ ○ ○20 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○25 ○ ○ ○ ○ ○30 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○35 ○40 ○ ○ ○ ○ ○ ○ ○50 ○ ○ ○ ○ ○ ○ ○60 ○ ○ ○70 ○80 ○ ○ ○
100 ○ ○ ○ ○150 ○200 ○
Pad type
Oval
Code E
Pad size (mm
)
2×4 ○3.5×7 ○4×10 ○5×10 ○6×10 ○4×20 ○4×30 ○5×20 ○5×30 ○6×20 ○6×30 ○8×20 ○8×30 ○
-T8-M4
-M6
-M6
-M10
-PB15
-E10
-E20
※1.Holder for vacuum pad for packaging bag. ※2.Holder for soft series and soft bellows series.※3.Holder for oval series.
1119
Vacuum Pad SeriesVacuum Pad Holder Only
■ Model designation of Pad Holder (Ex.)
VP -M4 -6
②Connection configuration code
③Stroke
Vacuum pad
C
①Holder type
① .Holder type
-4J
④Port size and joint type
② .Connection configuration code
⑤Free holder or Fall prevention valve (Option)
⑥Filter (Option)
⑦-S3 Spec.
Code
Code
MA−A−−
A-EFixed typeTop port
MB−B−−
B-EFixed type Side port
MCSCC
OCLFC
−Spring type
Top port
MD−D
OD−−
Spring typeSide port
ME−E−−−
Fixed typeDirect mount
−−F−−−
Spring typeDirect mount
HCSpring type
Top port
HDSpring typeSide port
HDWSpring type
Dual side port
HEFixed typeSide port
HEWFixed type
Dual side port
Holder typeMini Standard
For specific padLow dust emission Slim Low dust emission No coverLow dust emission Low dust emission
Code -T4 -H3 -T8 -M4 -M6 -M10 -M20 -T15 -T40 -PB15 -E10 -E20Connection type Mount Insert Mount Screw Mount
Pad typeStandard
General ○ ○ ○ ○ ○ ○Deep ○ ○ ○Small ○
Soft ○ ○ ○ ○Soft Bellows ○ ○ ○ ○Skidproof ○ ○Bellows ○ ○ ○ ○
Multi-bellows ○ ○For packaging bag ○
Ultrathin ○Flat ○ ○
Mark-free ○ ○Sponge ○ ○
Oval ○ ○ ○
Type
MiniSlim
Standard※4No cover※1※2
Type※3
※1.Holder code:LFC is Low dust emission holder※2.Holder code:A-E and B-E are for Oval series vacuum pad.※3.Holder code:HC, HD, HDW, HE and HEW are for Soft series and Soft Bellows vacuum pad.※4.Holder code:A and E includes special holders for vacuum pad for packaging bag.
1120
https://en.pisco.co.jp/
④ .Port size and joint type
⑤ .Free holder or Fall prevention valve (Option) ⑥ .Filter (Option)CodeOption
CodeConnection config. code
F15-M4, -M6
F30-M6
FHFree holder articulation angle:30°
FHHFree holder articulation angle:15°
ECVFall prevention valve
⑦ .-S3 spec.CodeSpec.
No code -S3
※ .Free holder, Fall prevention valve and Filter are not available when "-S3" is selected.Free holder, Fall prevention valve and Filter are not available when "-S3" is selected.Standard Metal parts material : Copper alloy free material, Sealing parts material : FKM or HNBR
③ .Stroke (No code entry for Holder code : MA, A, MB, B and F)
※ .Code in ( ) : Connection configuration code.
Code -2 -3 -4 -5 -6 -9 -10 -15 -20 -30 -40 -50Stroke(㎜) 2 3 4 5 6 9 10 15 20 30 40 50
Pad holder code
VPMC ○(-T4, -T8)
○(-M4, -M6)
VPSC ○(-H3, -T8)
VPC ○(-H3, -T8)
○(-M4, -M6)
○(-M4, -M6, -M10)
○(-M4, -M6)
○(-M4, -M6, -M20)
VPOC ○(-M6)
○(-M6)
○(-M6)
○(-M6)
VPLFC ○(-T4, -T8, -M4)
○(-T4, -T8, -M4, -M6)
○(-T4, -T8, -M4, -M6)
○(-T4, -T8, -M4, -M6)
VPHC ○(-T15, -T40)
VPMD ○(-T4, -T8)
○(-M4, -M6)
VPD ○(-H3, -T8)
○(-M4, -M6)
○(-M4, -M6, -M10)
○(-M4, -M6)
○(-M4, -M6, -M20)
VPOD ○(-M6)
○(-M6)
○(-M6)
○(-M6)
VPHD ○(-T15, -T40)
VPHDW ○(-T15, -T40)
Joint type Push-in fitting (mm)Barb fitting
(mm)Female / Male thread
Code -180J -2J -3J -4J -6J -8J -10J -12J -3B -4B -6B -M3 -M5 -M6 -M8 -M14 -G1 -G2 -G3 -G4
Size
Tube O.D. ø1.8 ø2 ø3 ø4 ø6 ø8 ø10 ø12Tube I. D. ø2 ø2.5 ø4
F. thread size M3×0.5 M5×0.8 M6×1 G1/8 G1/4M. thread size M5×0.8 M6×1 M8×1 M14×1 G1/8 G1/4 G3/8 G1/2
Connection config. code
-T4 ○ ○ ○ ○ ○ ○ ○ ○-H3 ○ ○ ○ ○ ○ ○ ○ ○ ○-T8 ○ ○ ○ ○ ○ ○ ○ ○ ○-M4 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○-M6 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○-M10 ○ ○ ○ ○-M20 ○ ○ ○ ○ ○-T15 ○ ○ ○ ○ ○ ○ ○ ○ ○-T40 ○ ○ ○ ○ ○ ○ ○ ○ ○-PB15 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○-E10 ○ ○ ○ ○ ○ ○ ○ ○ ○-E20 ○ ○ ○ ○ ○ ○ ○ ○ ○
※.Joint size differs depending on the holder type. Check the joint size by the holder dimensions lists in following pages.
1121
Vacuum Pad SeriesVacuum Pad Holder Only
VPMA
VPMA-T44 VPMA-T84 VPMA-M447 VPMA-M6-4J7
B(2
.5)
1.5
8L2
C
øD
2-2
ø2.7ø2
2-Hex.7
M5×0.5
L2
2-2
øDL1
C
2.5
(3.5
)
ø4ø3.2
2-HM
M
Hex.10 M4×0.7
øD
C2-T
B L2
4.5
2
2-H
2-3
10.9
ø4
ø8.4
22.3
16.4
21.
6
6.5
2-Hex.12
M6×1
M10×1
Hex.10
Fixed type / Top port / Push-in fitting / Mini holder
Unit:mm
Model codeTube O.D.
øDThread
MB L1 L2
Tube endC
Hex.H
TConnectionconfig. code
VPMA-T4-180J 1.8-
18.4-
15.9 8.4- - -T4VPMA-T4-2J 2
VPMA-T4-3J 3 19.1 16.6 9.4
VPMA-T8-180J 1.8M6 × 0.75 17.6 12 14.1 8.4 8
- -T8VPMA-T8-2J 2
VPMA-T8-3J 3 M8 × 0.75 18.3 12.5 14.8 9.4 10
VPMA-M4-3J 3 M8 × 0.75 16.8-
12.5 9.4 10 2-M4
VPMA-M4-4J7 4 M10 × 1 20.7 16.4 10.9 12 3
VPMA-M6-4J7 - - - - - - - - -M6
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec. is available for model codes with 7 in the table above.
※ .Tightening torque of a pad holder fixing bulkhead nut is as below.▪Connection config. code:-T4▶1.5~2N·m. ▪Connection config. code:-T8 and Tube O.D.:ø1.8, ø2mm▶2~3N·m.▪Connection config. code:-T8 and Tube O.D.:ø3mm▶2.5~3.5N·m.▪Connection config. code:-M4 and Tube O.D.:ø3mm▶2.5~3.5N·m.▪Connection config. code:-M4 and Tube O.D.:ø4mm and -M6▶5~7N·m.
RoHS Compliant Copper alloy free available CAD (2D&3D)
■ Fixed type holder dimensions
1122
https://en.pisco.co.jp/
VPMA
VPMA-T447 VPMA-T847 VPMA-M447 VPMA-M647
11.
5
øD
C
L8
2-2
ø2.7ø2
2-H1
M
2.5
2-2
ø6
8C
2
øD
3.5
ø4ø3.2
2-Hex.6M
øD
C12
2-2
4.5
2
2-Hex.8M6×0.75
Hex.10 M4×0.7
M6×1
M10×1
Hex.10
2-3
øD
716
ø8.4
21.
6
6.5
2-Hex.12
Fixed type / Top port / Barb fitting / Mini holder
Unit:mm
Model codeTube I.D.
øDThread
ML C
Hex.H
Connectionconfig. code
VPMA-T4-3B7 2 M4 × 0.5 14 6 6-T4
VPMA-T4-4B7 2.5 M5 × 0.5 15 7 7
VPMA-T8-3B7 2 M4 × 0.5-
6- -T8
VPMA-T8-4B7 2.5 M5 × 0.5 7
VPMA-M4-3B7 2- -
6- -M4
VPMA-M4-4B7 2.5 7
VPMA-M6-4B7 2.5- - - - -M6
VPMA-M6-6B7 4
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).※ .Tightening torque of a pad holder fixing bulkhead nut is as below.
▪Connection config. code:-T4, -T8 and Thread size:M4×0.5▶1~1.2N·m. ▪Connection config. code:-T4, -T8 and Thread size:M5×0.5▶1.5~2N·m.▪Connection config. code:-M4▶2~3N·m.▪Connection config. code:-M6▶5~7N·m
RoHS Compliant Copper alloy free available CAD (2D&3D)
1123
Vacuum Pad SeriesVacuum Pad Holder Only
VPA
VPA-H3-4J7 VPA-T847 VPA-M4-6J7 VPA-M647
52
ø4ø3
10.9
ø4
2-224
.310 2-Hex.8
M6×0.75 L1
2-TL3
12
C
2.5
(3.5
)
ø4ø3.2
øD
2-H1
M
42-
4
5.5
26.1
18.5
ø6
11.7
2-Hex.14
Hex.12
M12×1
M4×0.7 H2M6×1
M
ø8.4
2-4
øD
10C
L1L2
181.
6
2-H1
VPA-M204VPA-M104
øD
C
L110
2-520
12
2-Hex.24
Hex.22
M20×1
M10×1.5
øD
C
L120
2-10
30
13
2-Hex.30
M24×2
Hex.27
M20×2
Fixed type / Top port / Push-in fitting / Standard holderRoHS Compliant Copper alloy free available CAD (2D&3D)
Unit:mm
Model codeTube O.D.
øDThread
ML1 L2 L3
Tube endC
Hex.H1
Hex.H2
TConnectionconfig. code
VPA-H3-4J7 ー ー ー ー ー ー ー ー ー -H3
VPA-T8-4J7 4 M8 × 0.75 24.8ー
28.3 10.9 10ー
2-T8
VPA-T8-6J7 6 M10 × 1 25.6 29.1 11.7 12 3
VPA-M4-6J7 ー ー ー ー ー ー ー ー ー -M4
VPA-M6-3J 3M12 × 1 36.7 6
ー10.9 14 12
ー -M6VPA-M6-4J7 4
VPA-M6-6J7 6 M14 × 1 27.7 5.6 11.7 17 14
VPA-M10-4J 4ー
40.3ー ー
10.9ー ー ー -M10VPA-M10-6J 6 42.6 11.7
VPA-M10-8J 8 51.2 18.2
VPA-M20-6J 6
ー
66
ー ー
17
ー ー ー -M20VPA-M20-8J 8 66.7 18.2
VPA-M20-10J 10 73.7 20.7
VPA-M20-12J 12 78.9 23.3
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec. is available for model codes with 7 in the table above.
※ .Tightening torque of a pad holder fixing bulkhead nut is as below.Connection config. code -H3 -T8 -M4 -M6 -M10 -M20Tigntening torque (N·m) 2~3 5~7 12~14 18~21 19~21 40~50
1124
https://en.pisco.co.jp/
VPA
VPA-H3-4B7 VPA-T847 VPA-M4-6B7 VPA-M647
1.6
6
ø8.4
øD
34
7
2-4
18 2-Hex.14
Hex.12
M6×1
M12×1
5
ø4
2-2
157
8
2-Hex.10
M8×0.75
Hex.10 M4×0.7
øD
ø4ø3.2
2-HM
L 2-2
72.
53.5
2-2
8
78
2
ø4
ø2.5
ø32-Hex.8
M5×0.5
Fixed type / Top port / Barb fitting / Standard holderRoHS Compliant Copper alloy free available CAD (2D&3D)
VPA
VPA-M6-M67 VPA-M10-G17 VPA-M20-G27
M24×2
Hex.27
M20×2
G1/4
2-10
5030
20
1311
2-Hex.30
Hex.22
M20×1
M10×1.5
G1/8
30
2-520
10 128
2-Hex.24
Hex.12
M6×1
M12×1
ø8.4
2-4
618
1.6
2-Hex.14
Fixed type / Top port / Female thread / Standard holderRoHS Compliant Copper alloy free available CAD (2D&3D)
Unit:mm
Model codeTube I.D.
øDThread
ML
Hex.H
Connection config. code
VPA-H3-4B7 ー ー ー ー -H3
VPA-T8-4B7 2.5 M5 × 0.5 10.5 8-T8
VPA-T8-6B7 4 M8 × 0.75 12 10
VPA-M4-6B7 ー ー ー ー -M4
VPA-M6-4B7 2.5ー ー ー -M6
VPA-M6-6B7 4
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).※ .Tightening torque of a pad holder fixing bulkhead nut is as below.
Connection config. code -H3 -T8 -M4 -M6Tightening torque(N·m) 1.5~2 2.5~3.5 12~14
Unit:mm
Model codeConnectionconfig. code
VPA-M6-M67 -M6
VPA-M10-G17 -M10
VPA-M20-G27 -M20
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).
※ .Tightening torque of a pad holder fixing bulkhead nut is as below.Connection config. code -M6 -M10 -M20Tightening torque(N·m) 12~14 19~21 40~50
1125
Vacuum Pad SeriesVacuum Pad Holder Only
VPMB
VPMB-T447 VPMB-T847 VPMB-M447
VPMB-M647
11.
5
8
11
ø5
ø2.7ø2
4
□5
M3×0.5E
CøD
9.5
ø4ø3.2
ø6
12.5
2.5
3.5
5
E
C
øD□6
M4×0.7
4.5
612
19
ø10
E
øD
C
Hex.10
M4×0.7
M5×0.8
ø10
ø8.4
6.5
1.6
21.2
126 E
C
øD
Hex.10
M6×1
M5×0.8
Fixed type / Side port / Push-in fitting / Mini holder
Unit:mm
Model codeTube O.D.
øDE
Tube endC
Connection config. code
VPMB-T4-180J 1.812 8.4
-T4VPMB-T4-2J 2
VPMB-T4-3J 3 13 9.4
VPMB-T4-4J7 4 15 10.9
VPMB-T8-180J 1.812.5 8.4
-T8VPMB-T8-2J 2
VPMB-T8-3J 3 13.5 9.4
VPMB-T8-4J7 4 15.5 10.9
VPMB-M4-180J 1.813.7 8.4
-M4VPMB-M4-2J 2
VPMB-M4-3J 317.5 10.9
VPMB-M4-4J7 4
VPMB-M4-6J7 6 19.4 11.7
VPMB-M6-180J 1.813.7 8.4
-M6VPMB-M6-2J 2
VPMB-M6-3J 317.5 10.9
VPMB-M6-4J7 4
VPMB-M6-6J7 6 19.4 11.7
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).
RoHS Compliant Copper alloy free available CAD (2D&3D)
1126
https://en.pisco.co.jp/
VPMB
VPMB
VPMB-T447 VPMB-T847 VPMB-M447 VPMB-M647
11.
5
8
11
ø5
ø2.7ø2
4
E
øD
C
□5
M3×0.5
9.5
ø4ø3.2
ø612
.52.
53.
55 E
øD
C
□6
M4×0.7
Hex.10 M4×0.7
M5×0.8
4.5
612
19
ø10
EC
øD
M6×1Hex.10
M5×0.8ø10
ø8.4
6.5
1.6
21.2
126 E
C
øD
VPMB-T4-M37 VPMB-T8-M37 VPMB-M4-M57 VPMB-M6-M57
M3×0.5
M3×0.5
2.7
1.5
811
ø5
ø2.7ø21
4
2.4
□5
5
ø6.2深さ
0.1
2.7
ø4ø3.2
9.5
12.5
2.5
3.5
ø6
□6
M3×0.5M4×0.7
ø8.5
深さ
0.14
4.5
612
19
ø10
Hex.10
M5×0.8
M4×0.7
M5×0.8
ø8.5
深さ
0.14
ø10
ø8.4
6.5
1.6
21.2
126
Hex.10M6×1
M5×0.8
M5×0.8
Fixed type / Side port / Barb fitting / Mini holder
Fixed type / Side port / Female thread / Mini holder
Unit:mm
Model codeTube I.D.
øDE C
Connection config. code
VPMB-T4-3B7 2 10.9 6-T4VPMB-T4-4B7 2.5
11.9 7VPMB-T4-6B7 4
VPMB-T8-3B7 2 11.4 6-T8VPMB-T8-4B7 2.5
12.4 7VPMB-T8-6B7 4
VPMB-M4-3B7 2 13.4 6-M4VPMB-M4-4B7 2.5
14.9 7VPMB-M4-6B7 4
VPMB-M6-3B7 2 13.4 6-M6VPMB-M6-4B7 2.5
14.9 7VPMB-M6-6B7 4
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).
Unit:mm
Model code Connection config. code
VPMB-T4-M37 -T4
VPMB-T8-M37 -T8
VPMB-M4-M57 -M4
VPMB-M6-M57 -M6
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).
RoHS Compliant Copper alloy free available CAD (2D&3D)
RoHS Compliant Copper alloy free available CAD (2D&3D)
1127
Vacuum Pad SeriesVacuum Pad Holder Only
VPB-H347 VPB-T847 VPB-M447 VPB-M647
VPB-M204VPB-M104
M3×0.5
4.5
11
ø5
4
18
ø4ø3
1.5
E
øD
C5
M4×0.72.
55
203.
5ø8
13ø3.2
ø4
E
8
øD
C
M4×0.7
M6×1
18
86
28
ø12 E
C
øDHex.12M6×1
M6×1
287
1.6 ø8.4
818
ø12 E
C
øD
Hex.12
10
ø17
3823
10 E
øD
C
Hex.22M10×1.5
M8×1.25
13
6540
ø26
20
E
øD
C
Hex.30
M20×2
M16×2
RoHS Compliant Copper alloy free available CAD (2D&3D)
VPB Fixed type / Side port / Push-in fitting / Standard holder
1128
https://en.pisco.co.jp/
Unit:mm
Model codeTube O.D.
øDE
Tube endC
Connection config. code
VPB-H3-180J 1.812 8.4
-H3VPB-H3-2J 2
VPB-H3-3J 3 13 9.4
VPB-H3-4J7 4 15 10.9
VPB-T8-180J 1.812.7 8.4
-T8VPB-T8-2J 2
VPB-T8-3J 316.5 10.9
VPB-T8-4J7 4
VPB-T8-6J7 6 18.4 11.7
VPB-M4-3J 318.6 10.9
-M4VPB-M4-4J7 4
VPB-M4-6J7 6 19.9 11.7
VPB-M6-3J 318.6 10.9
-M6VPB-M6-4J7 4
VPB-M6-6J7 6 19.9 11.7
VPB-M10-4J 4 21.2 10.9-M10VPB-M10-6J 6 23.5 11.7
VPB-M10-8J 8 32.1 18.2
VPB-M20-6J 6 30.9 17-M20VPB-M20-8J 8 31.6 18.2
VPB-M20-10J 10 38.6 20.7
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec. is available for model codes with 7 in the table above.
1129
Vacuum Pad SeriesVacuum Pad Holder Only
VPB-H347 VPB-T847 VPB-M447 VPB-M647
4.5
11ø5
4
18
ø4ø3
1.5
EøD
C5
M3×0.5
13
2.5
520
3.5
ø8
ø3.2ø4
E
C
øD
8
M4×0.7
18
86
28
ø12 15.9
7
øD
Hex.12M4×0.7
M6×1
287
1.6 ø8.4
818
ø12 15.9
7
øD
Hex.12M6×1
M6×1
RoHS Compliant Copper alloy free available CAD (2D&3D)
VPB Fixed type / Side port / Barb fitting / Standard holder
Unit:mm
Model codeTube I.D.
øDE C
Connection config. code
VPB-H3-3B7 2 10.9 6-H3VPB-H3-4B7 2.5
11.9 7VPB-H3-6B7 4
VPB-T8-3B7 2 12.4 6-T8VPB-T8-4B7 2.5
13.9 7VPB-T8-6B7 4
VPB-M4-4B7 2.5ー ー -M4
VPB-M4-6B7 4
VPB-M6-4B7 2.5ー ー -M6
VPB-M6-6B7 4
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).
1130
https://en.pisco.co.jp/
VPB-H3-M37 VPB-T8-M57 VPB-M4-M57 VPB-M6-M67
VPB-M10-G17 VPB-M20-G27
M3×0.5
M3×0.5
2.5
4.5
ø5
4
11
18
ø4ø3
1.5
5 3.52013
5
2.53.
5
ø8
ø4ø3.2
8
M5×0.8
M4×0.7
M6×1
M4×0.7
M6×1
4
68
2818
ø12
Hex.12 ø8.4
4
7
1.6
8
2818
ø12
Hex.12
M6×1
M6×1
M6×1
ø16深さ
0.1
10
7
ø17
3823
10
Hex.22
G1/8
M10×1.5
M8×1.25
ø20深さ
0.19.5
6540
ø2613
20
Hex.30
M20×2
G1/4
M16×2
RoHS Compliant Copper alloy free available CAD (2D&3D)
VPB Fixed type / Side port / Female thread / Standard holder
Unit:mm
Model codeConnectionconfig. code
VPB-H3-M37 -H3
VPB-T8-M57 -T8
VPB-M4-M57 -M4
VPB-M6-M67 -M6
VPB-M10-G17 -M10
VPB-M20-G27 -M20
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).
1131
Vacuum Pad SeriesVacuum Pad Holder Only
VPME-T4-M37 VPME-T8-M57
2.5
2.5
1.5
0.5
2.5
ø2.7ø2
Hex.5.5Gasket
M3×0.5
3
ø4ø3.2
30.
52.
53.
5
Hex.7Gasket
M5×0.8
VPE-H3-M37 VPE-T8-M57
0.5
3.5
5
(9)
2.5
3
ø4ø3
Hex.5.5Gasket
M3×0.5
0.5
5(1
1.5)
32.
53.
5
ø4ø3.2
Hex.8
Gasket
M5×0.8
RoHS Compliant Copper alloy free available CAD (2D&3D)
RoHS Compliant Copper alloy free available CAD (2D&3D)
VPME
VPE
Fixed type / Direct mount / Mini holder
Fixed type / Direct mount / Standard holder
Unit:mm
Model codeConnectionconfig. code
VPME-T4-M37 -T4
VPME-T8-M57 -T8
Unit:mm
Model codeConnectionconfig. code
VPE-H3-M37 -H3
VPE-T8-M57 -T8
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).
1132
https://en.pisco.co.jp/
VPMC
VPMC-T4-24 VPMC-T8-24 VPMC-M4-447 VPMC-M6-447
M8×0.75
Hex.7
2-2
1.5
1
B
C
øD
2
3.5
ø2.7ø2
13
2-Hex.10
B
øD
C
ø4ø3.2
2
2-2
133.
52.
53.
5
2-Hex.10
Hex.7M8×0.75
Hex.10M4×0.7
M10×1
C
øD
B 2-3
16
4
4.56
2-Hex.12
ø8.4
øD
B
C6.
5
12.4
1.6
2-3
16
4
2-Hex.12
M6×1
Hex.10
M10×1
Spring type / Top port / Push-in fitting / Mini holder
Unit:mm
Model codeTube O.D.
øDB
Tube endC
Spring force(N)
Connection config. code
VPMC-T4-2-180J 1.826.2 8.4
0.2〜0.3 -T4VPMC-T4-2-2J 2
VPMC-T4-2-3J 3 27.2 9.4
VPMC-T8-2-180J 1.829.7 8.4
0.5〜0.6 -T8VPMC-T8-2-2J 2
VPMC-T8-2-3J 3 30.7 9.4
VPMC-M4-4-180J 1.830.9 8.4
1〜1.3 -M4VPMC-M4-4-2J 2
VPMC-M4-4-3J 334.7 10.9
VPMC-M4-4-4J7 4
VPMC-M6-4-180J 1.838.9 8.4
1〜1.3 -M6VPMC-M6-4-2J 2
VPMC-M6-4-3J 342.7 10.9
VPMC-M6-4-4J7 4
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec. is available for model codes with 7 in the table above.
※ .Tightening torque of a pad holder fixing bulkhead nut is as below.Connection config. code -T4 -T8 -M4 -M6Tightening torque(N·m) 2.5~3.5 4~6
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)2, 4
■ Spring type holder dimensions
1133
Vacuum Pad SeriesVacuum Pad Holder Only
VPMC
VPMC-T4-247 VPMC-T8-247 VPMC-M4-447 VPMC-M6-447
M8×0.75
Hex.7
2-2
1.5
1C
øD
B
2
3.5
ø2.7ø2
13
2-Hex.10
B
C
øD
ø4ø3.2
2
2-2
133.
52.
53.
5
2-Hex.10
Hex.7M8×0.75
øD
B
C
2-3
16
4
4.56
2-Hex.12
Hex.10M4×0.7M10×1 ø8.4
øD
B
C6.
5
12.4
1.6
2-3
16
4
2-Hex.12
M6×1
Hex.10
M10×1
Spring type / Top port / Barb fitting / Mini holder
Unit:mm
Model codeTube I.D.
øDB C
Spring force(N)
Connection config. code
VPMC-T4-2-3B7 2 25.1 60.2〜0.3 -T4VPMC-T4-2-4B7 2.5
26.1 7VPMC-T4-2-6B7 4
VPMC-T8-2-3B7 2 28.6 60.5〜0.6 -T8VPMC-T8-2-4B7 2.5
29.6 7VPMC-T8-2-6B7 4
VPMC-M4-4-3B7 2 30.6 61〜1.3 -M4VPMC-M4-4-4B7 2.5
32.1 7VPMC-M4-4-6B7 4
VPMC-M6-4-3B7 2 38.6 61〜1.3 -M6VPMC-M6-4-4B7 2.5
40.1 7VPMC-M6-4-6B7 4
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec. is available for model codes with 7 in the table above.
※ .Tightening torque of a pad holder fixing bulkhead nut is as below.Connection config. code -T4 -T8 -M4 -M6Tightening torque(N·m) 2.5~3.5 4~6
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)2, 4
1134
https://en.pisco.co.jp/
VPSC
VPSC-H3-347 VPSC-T8-347
Hex.7
M8×0.75B
C
øD
2-2
3
1314
.5
2.5
3.5
ø4ø3.2
ø10
2-Hex.10B
øD
C
2-2
3
13
ø10143 5.
5ø3
ø4
2-Hex.10
Hex.7
M8×0.75
Spring type / Top port / Push-in fitting / Slim holder
Unit:mm
Model codeTube O.D.
øDB
Tube endC
Spring force(N)
Connection config. code
VPSC-H3-3-180J 1.836.7 8.4
0.9〜1.9 -H3VPSC-H3-3-2J 2
VPSC-H3-3-3J 3 37.7 9.4
VPSC-H3-3-4J7 4 39.7 10.9
VPSC-T8-3-180J 1.837.2 8.4
0.9〜1.9 -T8VPSC-T8-3-2J 2
VPSC-T8-3-3J 3 38.2 9.4
VPSC-T8-3-4J7 4 40.2 10.9
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec. is available for model codes with 7 in the table above.
※ .Tightening torque of a pad holder fixing bulkhead nut is as below.Connection config. code -H3 -T8Tightening torque(N·m) 1.8~2.4
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)3
1135
Vacuum Pad SeriesVacuum Pad Holder Only
VPSC
VPSC
VPSC-H3-347 VPSC-T8-347
øD
B
C
2-2
3
1314
.5
2.5
3.5
ø4ø3.2
ø10
2-Hex.10
Hex.7
M8×0.75
B
C
øD
2-2
3
13
ø10143 5.
5
ø3ø4
2-Hex.10
Hex.7
M8×0.75
VPSC-H3-3-M37 VPSC-T8-3-M37
2-2
34
5.5
1314
3
ø10
ø3ø4
2-Hex.10M8×0.75
Hex.7
M3×0.5
3
2-213
14.5
ø4ø3.22.
53.
5
4
ø10
2-Hex.10
Hex.7
M8×0.75
M3×0.5
Spring type / Top port / Barb fitting / Slim holder
Spring type / Top port / Female thread / Slim holder
Unit:mm
Model codeTube I.D.
øDB C
Spring force(N)
Connection config. code
VPSC-H3-3-3B7 2 35.6 60.9〜1.9 -H3VPSC-H3-3-4B7 2.5
36.6 7VPSC-H3-3-6B7 4
VPSC-T8-3-3B7 2 36.1 60.9〜1.9 -T8VPSC-T8-3-4B7 2.5
37.1 7VPSC-T8-3-6B7 4
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec. is available for model codes with 7 in the table above.
※ .Tightening torque of a pad holder fixing bulkhead nut is as below.Connection config. code -H3 -T8Tightening torque(N·m) 1.8~2.4
Unit:mm
Model codeSpring force
(N)Connection config. code
VPSC-H3-3-M37 0.9〜1.9 -H3
VPSC-T8-3-M37 0.9〜1.9 -T8
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec. is available for model codes with 7 in the table above.
※ .Tightening torque of a pad holder fixing bulkhead nut is as below.Connection config. code -H3 -T8Tightening torque(N·m) 1.8~2.4
RoHS Compliant Copper alloy free available CAD (2D&3D)
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)3
Stroke (mm)3
1136
https://en.pisco.co.jp/
VPC
VPC-H3347
Hex.8
M12×1
C
øD
L3
2-4
L2L1
AS
ø13
ø4ø3
2-Hex.14
Spring type / Top port / Push-in fitting / Standard holder
Unit:mm
Model codeTube O.D.
ødA L1 L2 L3
Tube endC
StrokeS
Spring force(N)
Connectionconfig. code
VPC-H3-3-180J 1.8
4.5 13.5 13
35.4 8.4
3 0.9 � 1.9
-H3
VPC-H3-3-2J 2
VPC-H3-3-3J 339.2 10.9
VPC-H3-3-4J7 4
VPC-H3-3-6J7 6 41.1 11.7
VPC-H3-10-180J 1.8
6
23 17.5
49.4 8.4
10 0.6 � 1.7VPC-H3-10-2J 2
VPC-H3-10-3J 353.2 10.9
VPC-H3-10-4J 4
VPC-H3-10-6J 6 55.1 11.7
VPC-H3-15-180J 1.8
28 23.5
60.4 8.4
15 0.4 � 1.7VPC-H3-15-2J 2
VPC-H3-15-3J 364.2 10.9
VPC-H3-15-4J 4
VPC-H3-15-6J 6 66.1 11.7
VPC-H3-20-180J 1.8
33 28.5
70.4 8.4
20 0.3 � 1.8VPC-H3-20-2J 2
VPC-H3-20-3J 374.2 10.9
VPC-H3-20-4J 4
VPC-H3-20-6J 6 76.1 11.7
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec. is available for model codes with 7 in the table above.
※ .Tightening torque of a pad holder fixing bulkhead nut is as below.Connection config. code -H3Tightening torque(N·m) 8~10
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)3,10,15,20
1137
Vacuum Pad SeriesVacuum Pad Holder Only
VPC-T8347 VPC-M4347
Hex.8
M12×1
øD
L3
C
ø13
L2L1 S
2-4
2.5
3.5
ø4ø3.2
2-Hex.14
Hex.12
M14×1
M4×0.7
L3
C
øD
2-4
L2L1 S
A
ø16
2-Hex.17
VPC-M6347
Hex.12M6×1
M14×1
L11.
6 ø8.4
10
L3
C
øD
SL2
ø16
2-4
2-Hex.17
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)3,6,10,15,20
Unit:mm
Model codeTube O.D.
ødL1 L2 L3
Tube endC
StrokeS
Spring force(N)
Connectionconfig. code
VPC-T8-3-180J 1.8
16 13
37.9 8.4
3 0.9 � 1.9
-T8
VPC-T8-3-2J 2
VPC-T8-3-3J 341.7 10.9
VPC-T8-3-4J7 4
VPC-T8-3-6J7 6 43.6 11.7
VPC-T8-10-180J 1.8
23 17.5
49.4 8.4
10 0.8 � 2.7VPC-T8-10-2J 2
VPC-T8-10-3J 353.2 10.9
VPC-T8-10-4J 4
VPC-T8-10-6J 6 55.1 11.7
VPC-T8-15-180J 1.8
28 23.5
60.4 8.4
15 0.7 � 3.0VPC-T8-15-2J 2
VPC-T8-15-3J 364.2 10.9
VPC-T8-15-4J 4
VPC-T8-15-6J 6 66.1 11.7
VPC-T8-20-180J 1.8
33 28.5
70.4 8.4
20 0.9 � 3.4VPC-T8-20-2J 2
VPC-T8-20-3J 374.2 10.9
VPC-T8-20-4J 4
VPC-T8-20-6J 6 76.1 11.7
1138
https://en.pisco.co.jp/
Unit:mm
Model codeTube O.D.
ødA L1 L2 L3
Tube endC
StrokeS
Spring force(N)
Connectionconfig. code
VPC-M4-6-3J 34 18
20
50.7 10.96 4.0 � 7.1
-M4
VPC-M4-6-4J7 4
VPC-M4-6-6J7 6 52.1 11.7
VPC-M4-10-3J 3
6
22.555.2 10.9
10 2.0 � 5.2VPC-M4-10-4J 4
VPC-M4-10-6J 6 56.6 11.7
VPC-M4-15-3J 327.5 25
65.2 10.915 2.0 � 5.9VPC-M4-15-4J 4
VPC-M4-15-6J 6 66.6 11.7
VPC-M4-20-3J 334.5 34
81.2 10.920 1.1 � 4.8VPC-M4-20-4J 4
VPC-M4-20-6J 6 82.6 11.7
VPC-M6-6-3J 3
ー
18
20
50.7 10.96 7.0 � 12.6
-M6
VPC-M6-6-4J7 4
VPC-M6-6-6J7 6 52.1 11.7
VPC-M6-10-3J 324
56.7 10.910 3.3 � 10.0VPC-M6-10-4J 4
VPC-M6-10-6J 6 58.1 11.7
VPC-M6-15-3J 329 25
66.7 10.915 3.3 � 10.4VPC-M6-15-4J 4
VPC-M6-15-6J 6 68.1 11.7
VPC-M6-20-3J 336 34
82.7 10.920 2.0 � 8.7VPC-M6-20-4J 4
VPC-M6-20-6J 6 84.1 11.7
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec. is available for model codes with 7 in the table above.
※ .Tightening torque of a pad holder fixing bulkhead nut is as below.Connection config. code -T8 -M4 -M6Tightening torque(N·m) 8~10 4.5~6 4.5~6
1139
Vacuum Pad SeriesVacuum Pad Holder Only
Unit:mm
Model codeTube O.D.
ødB
Tube endC
Spring force(N)
Connection config. code
VPC-M10-10-4J 4 66.3 10.910.1 � 15.8 -M10VPC-M10-10-6J 6 68.6 11.7
VPC-M10-10-8J 8 77.2 18.2
VPC-M20-20-6J 6 135 17
14.0 � 25.5 -M20VPC-M20-20-8J 8 135.7 18.2
VPC-M20-20-10J 10 142.7 20.7
VPC-M20-20-12J 12 147.9 23.3
※ .Tightening torque of a pad holder fixing bulkhead nut is as below.Connection config. code -M10 -M20Tightening torque(N·m) 16~20 42~54
VPC-M20-204VPC-M10-104
B
øD
C
2-6
5626
27 10
ø26
12
2-Hex.27
Hex.19 M10×1.5
M22×1
B
øD
C
2-10
119
67.1
48
ø35
20.1
13
2-Hex.36
Hex.30
M30×2
M20×2
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)6,10,15,20
1140
https://en.pisco.co.jp/
VPC
VPC-H3347 VPC-T8347
Hex.8
M12×1
øD
L3
C
2-4
L2L1
AS
ø13
ø4ø3
2-Hex.14
Hex.8
M12×1L3
C
øD
ø13
L2L1 S
2-4
2.5
3.5
ø4ø3.2
2-Hex.14
Spring type / Top port / Barb fitting / Standard holder
Unit:mm
Model codeTube I.D.
ødA L1 L2 L3 C
StrokeS
Spring force(N)
Connectionconfig. code
VPC-H3-3-3B7 24.5 13.5 13
35.1 63 0.9 � 1.9
-H3
VPC-H3-3-4B7 2.536.6 7
VPC-H3-3-6B7 4
VPC-H3-10-3B 2
6
23 17.549.1 6
10 0.6 � 1.7VPC-H3-10-4B 2.550.6 7
VPC-H3-10-6B 4
VPC-H3-15-3B 228 23.5
60.1 615 0.4 � 1.7VPC-H3-15-4B 2.5
61.6 7VPC-H3-15-6B 4
VPC-H3-20-3B 233 28.5
70.1 620 0.3 � 1.8VPC-H3-20-4B 2.5
71.6 7VPC-H3-20-6B 4
VPC-T8-3-3B7 2
ー
16 1337.6 6
3 0.9 � 1.9
-T8
VPC-T8-3-4B7 2.539.1 7
VPC-T8-3-6B7 4
VPC-T8-10-3B 223 17.5
49.1 610 0.8 � 2.7VPC-T8-10-4B 2.5
50.6 7VPC-T8-10-6B 4
VPC-T8-15-3B 228 23.5
60.1 615 0.7 � 3.0VPC-T8-15-4B 2.5
61.6 7VPC-T8-15-6B 4
VPC-T8-20-3B 233 28.5
70.1 620 0.9 � 3.4VPC-T8-20-4B 2.5
71.6 7VPC-T8-20-6B 4
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).※ .Tightening torque of a pad holder fixing bulkhead nut is as below.
Connection config. code -H3 -T8Tightening torque(N·m) 8~10
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)3,10,15,20
1141
Vacuum Pad SeriesVacuum Pad Holder Only
VPC-M4347 VPC-M6347
Hex.12
M14×1
M4×0.7
L3
C
øD
2-4
L2L1 S
A
ø16
2-Hex.17
Hex.12M6×1
M14×1
L11.
6 ø8.4
10
L3
C
øD
SL2
ø16
2-4
2-Hex.17
Unit:mm
Model codeTube I.D.
ødA L1 L2 L3
StrokeS
Spring force(N)
Connectionconfig. code
VPC-M4-6-4B7 2.54 18
2048.1 6 4.0 � 7.1
-M4
VPC-M4-6-6B7 4
VPC-M4-10-4B 2.5
6
22.5 52.6 10 2.0 � 5.2VPC-M4-10-6B 4
VPC-M4-15-4B 2.527.5 25 62.6 15 2.0 � 5.9
VPC-M4-15-6B 4
VPC-M4-20-4B 2.534.5 34 78.6 20 1.1 � 4.8
VPC-M4-20-6B 4
VPC-M6-6-4B7 2.5
ー
1820
48.1 6 7.0 � 12.6
-M6
VPC-M6-6-6B7 4
VPC-M6-10-4B 2.524 54.1 10 3.3 � 10.0
VPC-M6-10-6B 4
VPC-M6-15-4B 2.529 25 64.1 15 3.3 � 10.4
VPC-M6-15-6B 4
VPC-M6-20-4B 2.536 34 80.1 20 2.0 � 8.7
VPC-M6-20-6B 4
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).※ .Tightening torque of a pad holder fixing bulkhead nut is as below.
Connection config. code -M4 -M6Tightening torque(N·m) 4.5~6
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)6,10,15,20
1142
https://en.pisco.co.jp/
VPC
VPC-H33-M57 VPC-T83-M57 VPC-M43-M67 VPC-M63-M67
Hex.8
M5×0.8
M12×1
2-4
L2L1
A
ø13
4.5
ø4ø3
2-Hex.14
S
Hex.8
M5×0.8
M12×1
ø13
L2L1 S
2-4 4.5
2.5
3.5
ø4ø3.2
2-Hex.14
Hex.12
M14×1
M4×0.7
M6×1
2-4
L2L1 S
A
ø16
5
2-Hex.17
Hex.12M6×1
M14×1
M6×1
ø8.4
SL2
L1
ø16
1.6
10
2-4 5
2-Hex.17
Spring type / Top port / Female thread / Standard holder
Unit:mm
Model code A L1 L2Stroke
SSpring force
(N)Connection config. code
VPC-H3-3-M57 4.5 13.5 13 3 0.9 � 1.9
-H3VPC-H3-10-M5
623 17.5 10 0.6 � 1.7
VPC-H3-15-M5 28 23.5 15 0.4 � 1.7
VPC-H3-20-M5 33 28.5 20 0.3 � 1.8
VPC-T8-3-M57
ー
16 13 3 0.9 � 1.9
-T8VPC-T8-10-M5 23 17.5 10 0.8 � 2.7
VPC-T8-15-M5 28 23.5 15 0.7 � 3.0
VPC-T8-20-M5 33 28.5 20 0.9 � 3.4
VPC-M4-6-M67 4 1820
6 4.0 � 7.1
-M4VPC-M4-10-M6
622.5 10 2.0 � 5.2
VPC-M4-15-M6 27.5 25 15 2.0 � 5.9
VPC-M4-20-M6 34.5 34 20 1.1 � 4.8
VPC-M6-6-M67
ー
1820
6 7.0 � 12.6
-M6VPC-M6-10-M6 24 10 3.3 � 10.0
VPC-M6-15-M6 29 25 15 3.3 � 10.4
VPC-M6-20-M6 36 34 20 2.0 � 8.7
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).※ .Tightening torque of a pad holder fixing bulkhead nut is as below.
Connection config. code -H3 -T8 -M4 -M6 -M10 -M20Tightening torque(N·m) 8~10 4.5~6 16~20 42~54
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)3,6,10,15,20
1143
Vacuum Pad SeriesVacuum Pad Holder Only
VPC-M10-10-G17 VPC-M20-20-G27
2-6
5626
27 10
ø26
127
2-Hex.27
Hex.19 M10×1.5
G1/8
M22×1
2-10
119
67.1
48
ø35
20.1
139.
5
2-Hex.36
Hex.30
M30×2
G1/4
M20×2
Unit:mm
Model codeSpring force
(N)Connection config. code
VPC-M10-10-G17 10.1 � 15.8 -M10
VPC-M20-20-G27 14.0 � 25.5 -M20
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).
※ .Tightening torque of a pad holder fixing bulkhead nut is as below.Connection config. code -M10 -M20Tightening torque(N·m) 16~20 42~54
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)10,20
1144
https://en.pisco.co.jp/
VPOC
ø8.4
B
1.6
49L
S
8C
øD
2-Hex.17
M6×1
M14×1
Spring type / Top port / Push-in fitting / No cover holder
Unit:mm
Model codeTube O.D.
øDB L
Tube endC
StrokeS
Spring force(N)
Connectionconfig. code
VPOC-M6-20-3J 359.7
3810.9
20 1.5〜4.9
-M6
VPOC-M6-20-4J 4
VPOC-M6-20-6J 6 61.1 11.7
VPOC-M6-30-3J 372.7
5110.9
30 1.1〜4.8VPOC-M6-30-4J 4
VPOC-M6-30-6J 6 74.1 11.7
VPOC-M6-40-3J 385.7
6410.9
40 1.0〜4.5VPOC-M6-40-4J 4
VPOC-M6-40-6J 6 87.1 11.7
VPOC-M6-50-3J 398.7
7710.9
50 0.9〜4.5VPOC-M6-50-4J 4
VPOC-M6-50-6J 6 100.1 11.7
※ .Tightening torque of a pad holder fixing bulkhead nut is 4~6N·m.
RoHS Compliant CAD (2D&3D)
Stroke (mm)20,30,40,50
1145
Vacuum Pad SeriesVacuum Pad Holder Only
VPOC
VPOC
8
ø8.4
B
1.6
49L
S
øD
7
2-Hex.17
M6×1
M14×1
M6×1
M14×1
M6×1
ø8.41.6
49L
8
S
5
2-Hex.17
Spring type / Top port / Barb fitting / No cover holder
Spring type / Top port / Female thread / No cover holder
Unit:mm
Model codeTube I.D.
øDB L
StrokeS
Spring force(N)
Connection config. code
VPOC-M6-20-4B 2.557.1 38 20 1.5〜4.9
-M6
VPOC-M6-20-6B 4
VPOC-M6-30-4B 2.570.1 51 30 1.1〜4.8
VPOC-M6-30-6B 4
VPOC-M6-40-4B 2.583.1 64 40 1.0〜4.5
VPOC-M6-40-6B 4
VPOC-M6-50-4B 2.596.1 77 50 0.9〜4.5
VPOC-M6-50-6B 4
※ .Tightening torque of a pad holder fixing bulkhead nut is 4~6N·m.
Unit:mm
Model code LStroke
SSpring force
(N)Connection config.
codeVPOC-M6-20-M6 38 20 1.5〜4.9
-M6VPOC-M6-30-M6 51 30 1.1〜4.8
VPOC-M6-40-M6 64 40 1.0〜4.5
VPOC-M6-50-M6 77 50 0.9〜4.5
※ .Tightening torque of a pad holder fixing bulkhead nut is 4~6N·m.
RoHS Compliant CAD (2D&3D)
RoHS Compliant CAD (2D&3D)
Stroke (mm)20,30,40,50
Stroke (mm)20,30,40,50
1146
https://en.pisco.co.jp/
VPMD
VPMD-T4-247 VPMD-T8-247 VPMD-M4-447
VPMD-M6-447
11.
52-
22
ø2.7ø2
2212
8.4 5.
4
EøD
C
2-Hex.8M6×0.75
□52
2-2
5.4
25.5
128.
42.
53.
5
ø4ø3.2
2-Hex.8M6×0.75
EC
øD
□6
8.5 4
2-3
34.5
1615
.5
4.5
EC
øD
2-Hex.12
M4×0.7
M10×1
Hex.10
Hex.10M6×1
M10×1
6.2
ø8.4
36.3
1.6
15.7
8.5
2-3
4
16
EC
øD2-Hex.12
Spring type / Side port / Push-in fitting / Mini holder
Unit:mm
Model codeTube O.D.
øDE
Tube endC
Spring force(N)
Connection config. code
VPMD-T4-2-180J 1.812.1 8.4
0.2 � 0.3 -T4VPMD-T4-2-2J 2
VPMD-T4-2-3J 3 13.1 9.4
VPMD-T4-2-4J7 4 15.1 10.9
VPMD-T8-2-180J 1.812.6 8.4
0.5 � 0.6 -T8VPMD-T8-2-2J 2
VPMD-T8-2-3J 3 13.6 9.4
VPMD-T8-2-4J7 4 15.6 10.9
VPMD-M4-4-180J 1.813.7 8.4
1.0 � 1.3 -M4VPMD-M4-4-2J 2
VPMD-M4-4-3J 317.5 10.9
VPMD-M4-4-4J7 4
VPMD-M4-4-6J7 6 19.4 11.7
VPMD-M6-4-180J 1.813.7 8.4
1.0 � 1.3 -M6VPMD-M6-4-2J 2
VPMD-M6-4-3J 317.5 10.9
VPMD-M6-4-4J7 4
VPMD-M6-4-6J7 6 19.4 11.7
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec. is available for model codes with 7 in the table above.
※ .Tightening torque of a pad holder fixing bulkhead nut is as below.Connection config. code -T4 -T8 -M4 -M6Tightening torque(N·m) 2.5~3.5 4~6
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)2, 4
1147
Vacuum Pad SeriesVacuum Pad Holder Only
VPMD
VPMD-T4-247 VPMD-T8-247 VPMD-M4-447
VPMD-M6-447
11.
52-
22
ø2.7ø2
2212
8.4 5.
4 øDE
C
2-Hex.8M6×0.75
□5
2-2
5.4
225.5
128.
42.
53.
5
ø4ø3.2
EC
øD
2-Hex.8M6×0.75
□6M4×0.7
M10×1
Hex.10
8.5 4
2-3
34.5
1615
.5
4.5 øD
EC
2-Hex.12
Hex.10
M6×1
M10×1
6.2
ø8.4
36.3
1.6
15.7
8.5
2-3
4
16
EC
øD
2-Hex.12
Spring type / Side port / Barb fitting / Mini holder
Unit:mm
Model codeTube I.D.
øDE
Tube endC
Spring force(N)
Connection config. code
VPMD-T4-2-3B7 2 11 60.2 � 0.3 -T4VPMD-T4-2-4B7 2.5
12 7VPMD-T4-2-6B7 4
VPMD-T8-2-3B7 2 11.5 60.5 � 0.6 -T8VPMD-T8-2-4B7 2.5
12.5 7VPMD-T8-2-6B7 4
VPMD-M4-4-3B7 2 13.4 61.0 � 1.3 -M4VPMD-M4-4-4B7 2.5
14.9 7VPMD-M4-4-6B7 4
VPMD-M6-4-3B7 2 13.4 61.0 � 1.3 -M6VPMD-M6-4-4B7 2.5
14.9 7VPMD-M6-4-6B7 4
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec. is available for model codes with 7 in the table above.
※ .Tightening torque of a pad holder fixing bulkhead nut is as below.Connection config. code -T4 -T8 -M4 -M6Tightening torque(N·m) 2.5~3.5 4~6
※ .Visit our website for weight.
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)2, 4
1148
https://en.pisco.co.jp/
VPMD
VPMD-T4-2-M37 VPMD-T8-2-M37 VPMD-M4-4-M57
VPMD-M6-4-M57
1.5
2.7
22-
2
ø2.7ø21
2212
8.4 5.
4
2-Hex.8M6×0.75
M3×0.5
□52-
25.
425.5
128.
42.
53.
5ø4
ø3.2
2
2.7
2-Hex.8M6×0.75
M3×0.5
□6
ø8.5
深さ
0.14
2-3
8.5 4
34.5
1615
.5
4.5
2-Hex.12
M5×0.8Hex.10 M4×0.7
M10×1
6.2
ø8.5
深さ
0.1
ø8.4
36.3
1.6
15.7
8.5
4
2-3
4
16
2-Hex.12
M5×0.8
Hex.10 M6×1
M10×1
Spring type / Side port / Female thread / Mini holder
Unit:mm
Model codeSpring force
(N)Connection config. code
VPMD-T4-2-M37 0.2 � 0.3 -T4
VPMD-T8-2-M37 0.5 � 0.6 -T8
VPMD-M4-4-M57 1.0 � 1.3 -M4
VPMD-M6-4-M57 1.0 � 1.3 -M6
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec. is available for model codes with 7 in the table above.
※ .Tightening torque of a pad holder fixing bulkhead nut is as below.Connection config. code -T4 -T8 -M4 -M6Tightening torque(N·m) 2.5~3.5 4~6
※ .Visit our website for weight.
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)2, 4
1149
Vacuum Pad SeriesVacuum Pad Holder Only
VPD
VPD-H3347 VPD-T8347 VPD-M4347
øP
S
B
A
E2
2-T
L2L1
3
ø4ø3
E1
øD
C
2-H1
H2
M
E2
2-T
S
BL2
L1
øP2.
53.
5
ø4ø3.2
E1C
øD
2-H1
H2
M
M4×0.7 Hex.12
M14×1
A
E2
BL2
L1S
ø16
2-4
E1
øD
C
2-Hex.17
Spring type / Side port / Push-in fitting / Standard holder
Unit:mm
Model codeTube O.D.øD
ThreadM
A B L1 L2 E1 E2 øPTube endC
Hex.H1
Hex.H2
TStrokeS
Spring force(N)
Connectionconfig. code
VPD-H3-3-180J 1.8
M8 × 0.75 4.5 36 20 13
12.7
12.5 10
8.4
10 ⃞ 8 2 3 0.9 � 1.9
-H3
VPD-H3-3-2J 2
VPD-H3-3-3J 316.5 10.9
VPD-H3-3-4J7 4
VPD-H3-3-6J7 6 18.4 11.7
VPD-H3-10-180J 1.8
M12 × 1 6
51.6 31 17.5
13.7
21
13
8.4
14 10 4
10 0.6 � 1.7VPD-H3-10-2J 2
VPD-H3-10-3J 317.5 10.9
VPD-H3-10-4J 4
VPD-H3-10-6J 6 18.9 11.7
VPD-H3-15-180J 1.8
62.6 36 23.5
13.7
26
8.4
15 0.4 � 1.7VPD-H3-15-2J 2
VPD-H3-15-3J 317.5 10.9
VPD-H3-15-4J 4
VPD-H3-15-6J 6 18.9 11.7
VPD-H3-20-180J 1.8
72.6 41 28.5
13.7
31
8.4
20 0.3 � 1.8VPD-H3-20-2J 2
VPD-H3-20-3J 317.5 10.9
VPD-H3-20-4J 4
VPD-H3-20-6J 6 18.9 11.7
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)3,6,10,15,20
1150
https://en.pisco.co.jp/
Unit:mm
Model codeTube O.D.øD
ThreadM
A B L1 L2 E1 E2 øPTube endC
Hex.H1
Hex.H2
TStrokeS
Spring force(N)
Connectionconfig. code
VPD-T8-3-180J 1.8
M8 × 0.75
ー
37.5 21.5 13
12.7
13 10
8.4
10 ⃞ 8 2 3 0.9 � 1.9
-T8
VPD-T8-3-2J 2
VPD-T8-3-3J 316.5 10.9
VPD-T8-3-4J7 4
VPD-T8-3-6J7 6 18.4 11.7
VPD-T8-10-180J 1.8
M12 × 1
52.6 32 17.5
14.7
21
13
8.4
14 12 4
10 0.8 � 2.7VPD-T8-10-2J 2
VPD-T8-10-3J 318.5 10.9
VPD-T8-10-4J 4
VPD-T8-10-6J 6 19.9 11.7
VPD-T8-15-180J 1.8
63.6 37 23.5
14.7
26
8.4
15 0.7 � 3.0VPD-T8-15-2J 2
VPD-T8-15-3J 318.5 10.9
VPD-T8-15-4J 4
VPD-T8-15-6J 6 19.9 11.7
VPD-T8-20-180J 1.8
73.6 42 28.5
14.7
31
8.4
20 0.9 � 3.4VPD-T8-20-2J 2
VPD-T8-20-3J 318.5 10.9
VPD-T8-20-4J 4
VPD-T8-20-6J 6 19.9 11.7
VPD-M4-6-3J 3
ー
5.5 50.1 27
20
18.618.5
ー
10.9
ー ー ー
6 4.0 � 7.1
-M4
VPD-M4-6-4J7 4
VPD-M4-6-6J7 6 19.9 11.7
VPD-M4-10-3J 3
4
55.1 3218.6
2510.9
10 2.0 � 5.2VPD-M4-10-4J 4
VPD-M4-10-6J 6 19.9 11.7
VPD-M4-15-3J 365.1 37 25
18.630
10.915 2.0 � 5.9VPD-M4-15-4J 4
VPD-M4-15-6J 6 19.9 11.7
VPD-M4-20-3J 381.1 44 34
18.637
10.920 1.1 � 4.8VPD-M4-20-4J 4
VPD-M4-20-6J 6 19.9 11.7
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec. is available for model codes with 7 in the table above.
※ .Tightening torque of a pad holder fixing bulkhead nut is as below.Connection config. code -H3 -T8 -M4Stroke(㎜) 3 10 15 20 3 10 15 20 6 10 15 20Tightening torque(N·m) 1.8~2.4 8~10 1.8~2.4 8~10 4.5~6
1151
Vacuum Pad SeriesVacuum Pad Holder Only
VPD-M6347
VPD-M10-104
VPD-M20-204
M6×1
Hex.12
M14×1
5.5
L1
1.6 ø8.4
E2
2-4
S
BL2
ø16 E1C
øD
2-Hex.17
Hex.22
M22×1
M10×1.5
10
30
2-6
7426
4510
ø26E
øD
C
2-Hex.27
Hex.30
M30×2
M20×2
2-10
13
42.1
ø35
20.1
123.
367
.148
E
øD
C
2-Hex.36
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)6,10,15,20
1152
https://en.pisco.co.jp/
Unit:mm
Model codeTube O.D.
øDB L1 L2 E1 E2
Tube endC
StrokeS
Spring force(N)
Connectionconfig. code
VPD-M6-6-3J 350.1 27
20
18.618.5
10.96 7.0 〜 12.6
-M6
VPD-M6-6-4J7 4
VPD-M6-6-6J7 6 19.9 11.7
VPD-M6-10-3J 356.1 33
18.624.5
10.910 3.3 〜 10.0VPD-M6-10-4J 4
VPD-M6-10-6J 6 19.9 11.7
VPD-M6-15-3J 366.1 38 25
18.629.5
10.915 3.3 〜 10.4VPD-M6-15-4J 4
VPD-M6-15-6J 6 19.9 11.7
VPD-M6-20-3J 382.1 45 34
18.636.5
10.920 2.0 〜 8.7VPD-M6-20-4J 4
VPD-M6-20-6J 6 19.9 11.7
VPD-M10-10-4J 4ー ー ー
21.2ー
10.9ー 10.1 〜 15.8 -M10VPD-M10-10-6J 6 23.5 11.7
VPD-M10-10-8J 8 32.1 18.2
VPD-M20-20-6J 6ー ー ー
30.9ー
17ー 14.0 〜 25.5 -M20VPD-M20-20-8J 8 31.6 18.2
VPD-M20-20-10J 10 38.6 20.7
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec. is available for model codes with 7 in the table above.
※ .Tightening torque of a pad holder fixing bulkhead nut is as below.Connection config. code -M6 -M10 -M20Tightening torque(N·m) 4.5~6 16~20 42~54
1153
Vacuum Pad SeriesVacuum Pad Holder Only
VPD
VPD-H3347 VPD-T8347 VPD-M4347
VPD-M6347
øP
S
B
A
E2
2-T
L2L1
3
ø4ø3
E1C
øD
2-H1
H2
M
E2
2-T
S
BL2
L1
øP
2.5
3.5
ø4ø3.2
E1C
øD
2-H1
H2
M
A
E2
BL2
L1S
ø16
2-4
15.9
øD
7
2-Hex.17
M4×0.7
Hex.12
M14×1
5.5
L1
1.6 ø8.4
E2
2-4
S
BL2
ø16 15.97
øD
2-Hex.17
M6×1
Hex.12
M14×1
Spring type / Side port / Barb fitting / Standard holder
Unit:mm
Model codeTube I.D.øD
ThreadM
A B L1 L2 E1 E2 øP CHex.H1
Hex.H2
TStrokeS
Spring force(N)
Connectionconfig. code
VPD-H3-3-3B7 2M8 × 0.75 4.5 36 20 13
12.412.5 10
610 ⃞ 8 2 3 0.9 � 1.9
-H3
VPD-H3-3-4B7 2.513.9 7
VPD-H3-3-6B7 4
VPD-H3-10-3B 2
M12 × 1 6
51.6 31 17.513.4
21
13
6
14 10 4
10 0.6 � 1.7VPD-H3-10-4B 2.514.9 7
VPD-H3-10-6B 4
VPD-H3-15-3B 262.6 36 23.5
13.426
615 0.4 � 1.7VPD-H3-15-4B 2.5
14.9 7VPD-H3-15-6B 4
VPD-H3-20-3B 272.6 41 28.5
13.431
620 0.3 � 1.8VPD-H3-20-4B 2.5
14.9 7VPD-H3-20-6B 4
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)3,6,10,15,20
1154
https://en.pisco.co.jp/
Unit:mm
Model codeTube I.D.øD
ThreadM
A B L1 L2 E1 E2 øP CHex.H1
Hex.H2
TStrokeS
Spring force(N)
Connectionconfig. code
VPD-T8-3-3B7 2M8 × 0.75
ー
37.5 21.5 1312.4
13 106
10 □8 2 3 0.9 � 1.9
-T8
VPD-T8-3-4B7 2.513.9 7
VPD-T8-3-6B7 4
VPD-T8-10-3B 2
M12 × 1
52.6 32 17.514.4
21
13
6
14 12 4
10 0.8 � 2.7VPD-T8-10-4B 2.515.9 7
VPD-T8-10-6B 4
VPD-T8-15-3B 263.6 37 23.5
14.426
615 0.7 � 3.0VPD-T8-15-4B 2.5
15.9 7VPD-T8-15-6B 4
VPD-T8-20-3B 273.6 42 28.5
14.431
620 0.9 � 3.4VPD-T8-20-4B 2.5
15.9 7VPD-T8-20-6B 4
VPD-M4-6-4B7 2.5
ー
5.5 50.1 2720
ー
18.5
ー ー ー ー ー
6 4.0 � 7.1
-M4
VPD-M4-6-6B7 4
VPD-M4-10-4B 2.5
4
55.1 32 25 10 2.0 � 5.2VPD-M4-10-6B 4
VPD-M4-15-4B 2.565.1 37 25 30 15 2.0 � 5.9
VPD-M4-15-6B 4
VPD-M4-20-4B 2.581.1 44 34 37 20 1.1 � 4.8
VPD-M4-20-6B 4
VPD-M6-6-4B7 2.5
ー ー
50.1 2720
ー
18.5
ー ー ー ー ー
6 7.0 � 12.6
-M6
VPD-M6-6-6B7 4
VPD-M6-10-4B 2.556.1 33 24.5 10 3.3 � 10.0
VPD-M6-10-6B 4
VPD-M6-15-4B 2.566.1 38 25 29.5 15 3.3 � 10.4
VPD-M6-15-6B 4
VPD-M6-20-4B 2.582.1 45 34 36.5 20 2.0 � 8.7
VPD-M6-20-6B 4
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec. is available for model codes with 7 in the table above.
※ .Tightening torque of a pad holder fixing bulkhead nut is as below.Connection config. code -H3 -T8 -M4 -M6Stroke(㎜) 3 10 15 20 3 10 15 20 6 10 15 20 6 10 15 20Tightening torque(N·m) 1.8~2.4 8~10 1.8~2.4 8~10 4.5~6
1155
Vacuum Pad SeriesVacuum Pad Holder Only
VPD
VPD-H33-M57 VPD-T83-M57 VPD-M43-M67 VPD-M63-M67
VPD-M10-10-G17 VPD-M20-20-G27
ø8.5深さ
0.1
4.5
B
A
E
2-T
L2L1
S
øP
3
ø4ø3
2-H1
H2
M5×0.8
ø8.5深さ
0.1
4.5
2-T
S
BL2
L1
EøP
2.5
3.5
ø4ø3.2
2-H1
H2
M5×0.8M4×0.7
M6×1
Hex.12
A
ø9.6深さ
0.1
5B
L2L1
S Eø16
2-4
2-Hex.17
Hex.12
M14×1
M6×1
5.5
ø9.6深さ
0.1
5
ø8.4
2-4
S
BL2
L1
E
1.6
ø16
2-Hex.17
M6×1
M14×1
MMø1
6深さ
0.1
102-
6
7
30
7426
4510
ø26
2-Hex.27
Hex.22
G1/8
M22×1
M10×1.5
ø20深さ
0.1
9.5
2-10
13
42.1
ø35
20.1
123.
367
.148
2-Hex.36
Hex.30
G1/4
M30×2
M20×2
Spring type / Side port / Female thread / Standard holderRoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)3,6,10,15,20
1156
https://en.pisco.co.jp/
Unit:mm
Model codeThread
MA B L1 L2 E øP
Hex.H1
Hex.H2
TStroke
SSpring force
(N)Connectionconfig. code
VPD-H3-3-M57 M8 × 0.75 4.5 36 20 13 12.5 10 10 ⃞ 8 2 3 0.9 � 1.9
-H3VPD-H3-10-M5
M12 × 1 651.6 31 17.5 21
13 14 10 410 0.6 � 1.7
VPD-H3-15-M5 62.6 36 23.5 26 15 0.4 � 1.7
VPD-H3-20-M5 72.6 41 28.5 31 20 0.3 � 1.8
VPD-T8-3-M57 M8 × 0.75
ー
37.5 21.5 13 13 10 10 ⃞ 8 2 3 0.9 � 1.9
-T8VPD-T8-10-M5
M12 × 152.6 32 17.5 21
13 14 12 410 0.8 � 2.7
VPD-T8-15-M5 63.6 37 23.5 26 15 0.7 � 3.0
VPD-T8-20-M5 73.6 42 28.5 31 20 0.9 � 3.4
VPD-M4-6-M67
ー
5.5 50.1 2720
18.5
ー ー ー ー
6 4.0 � 7.1
-M4VPD-M4-10-M6
455.1 32 25 10 2.0 � 5.2
VPD-M4-15-M6 65.1 37 25 30 15 2.0 � 5.9
VPD-M4-20-M6 81.1 44 34 37 20 1.1 � 4.8
VPD-M6-6-M67
ー ー
50.1 2720
18.5
ー ー ー ー
6 7.0 � 12.6
-M6VPD-M6-10-M6 56.1 33 24.5 10 3.3 � 10.0
VPD-M6-15-M6 66.1 38 25 29.5 15 3.3 � 10.4
VPD-M6-20-M6 82.1 45 34 36.5 20 2.0 � 8.7
VPD-M10-10-G17 ー ー ー ー ー ー ー ー ー ー ー 10.1 � 15.8 -M10
VPD-M20-20-G27 ー ー ー ー ー ー ー ー ー ー ー 14.0 � 25.5 -M20
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec. is available for model codes with 7 in the table above.
※ .Tightening torque of a pad holder fixing bulkhead nut is as below.Connection config. code -H3 -T8 -M4 -M6 -M10 -M20Stroke(㎜) 3 10 15 20 3 10 15 20 6 10 15 20 6 10 15 20 10 20Tightening torque(N·m) 1.8~2.4 8~10 1.8~2.4 8~10 4.5~6 16~20 42~54
1157
Vacuum Pad SeriesVacuum Pad Holder Only
VPOD
M6×1
Hex.14
M14×1
5.5
ø8.4
E2
B
49L S
1.6
CE1
øD
2-Hex.17
Spring type / Side port / Push-in fitting / No cover holder
Unit:mm
Model codeTube O.D.
øDB L E1 E2
Tube endC
StrokeS
Spring force(N)
Connectionconfig. code
VPOD-M6-20-3J 361.6 49.5
19.641
10.920 1.5〜4.9
-M6
VPOD-M6-20-4J 4
VPOD-M6-20-6J 6 20.9 11.7
VPOD-M6-30-3J 374.6 62.5
19.654
10.930 1.1〜4.8VPOD-M6-30-4J 4
VPOD-M6-30-6J 6 20.9 11.7
VPOD-M6-40-3J 387.6 75.5
19.667
10.940 1.0〜4.5VPOD-M6-40-4J 4
VPOD-M6-40-6J 6 20.9 11.7
VPOD-M6-50-3J 3100.6 88.5
19.680
10.950 0.9〜4.5VPOD-M6-50-4J 4
VPOD-M6-50-6J 6 20.9 11.7
※ .Tightening torque of a pad holder fixing bulkhead nut is 4.5~6N·m.
RoHS Compliant CAD (2D&3D)
Stroke (mm)20,30,40,50
1158
https://en.pisco.co.jp/
VPOD
VPOD
M6×1
Hex.14
M14×1
5.5
ø8.4
B
49L S
1.6
E
17
øD
7
2-Hex.17
5.5 ø9
.6深さ
0.15
ø8.4
E
B
49L S
1.6
2-Hex.17
Hex.14
M14×1
M6×1
Spring type / Side port / Barb fitting / No cover holder
Spring type / Side port / Female thread / No cover holder
Unit:mm
Model codeTube I.D.
øDB L E
StrokeS
Spring force(N)
Connectionconfig. code
VPOD-M6-20-4B 2.561.6 49.5 41 20 1.5〜4.9
-M6
VPOD-M6-20-6B 4
VPOD-M6-30-4B 2.574.6 62.5 54 30 1.1〜4.8
VPOD-M6-30-6B 4
VPOD-M6-40-4B 2.587.6 75.5 67 40 1.0〜4.5
VPOD-M6-40-6B 4
VPOD-M6-50-4B 2.5100.6 88.5 80 50 0.9〜4.5
VPOD-M6-50-6B 4
※ .Tightening torque of a pad holder fixing bulkhead nut is 4.5~6N·m.
Unit:mm
Model code B L EStroke
SSpring force
(N)Connection config. code
VPOD-M6-20-M6 61.6 49.5 41 20 1.5〜4.9
-M6VPOD-M6-30-M6 74.6 62.5 54 30 1.1〜4.8
VPOD-M6-40-M6 87.6 75.5 67 40 1.0〜4.5
VPOD-M6-50-M6 100.6 88.5 80 50 0.9〜4.5
※ .Tightening torque of a pad holder fixing bulkhead nut is 4.5~6N·m.
RoHS Compliant CAD (2D&3D)
RoHS Compliant CAD (2D&3D)
Stroke (mm)20,30,40,50
Stroke (mm)20,30,40,50
1159
Vacuum Pad SeriesVacuum Pad Holder Only
VPF
VPF-H37 VPF-T87 VPF-M47 VPF-M67
5
3
ø4ø3
2818
.5(9
.5)
ø14
Hex.12
M10×1
Hex.12
M10×1
ø3.2ø4
3ø14
28.5
(9.5
)19
2.5
3.5
5.8
ø19
4331
.38
M4×0.7Hex.12
Hex.17
M14×1
M6×1
Hex.12
Hex.17
M14×1
ø8.4
4432
.3
5.8
10 1.6
ø19
Spring type / Direct mount / Standard holder
Unit:mm
Model codeSpring force
(N)Connection config. code
VPF-H37 2.3 � 3.9 -H3
VPF-T87 2.3 � 3.9 -T8
VPF-M47 7.9 � 15.0 -M4
VPF-M67 7.9 � 15.0 -M6
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).※ .Tightening torque for fixing a pad holder is 4.5~6N·m.
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)3,5.8
1160
https://en.pisco.co.jp/
VPHE
VPHE
VPHE-T1547 VPHE-T4047
2.5
2
ø8.7
13
22.5
8
ø5.2
øD
CE
Hex.12 M5×0.8
15
30
10
ø5.4
ø7.5ø6.5
510
øD
CE
Hex.12 M5×0.8
VPHE-T1547 VPHE-T4047M5×0.8
2.5
2
ø8.7
13
22.5
8
ø5.2
øD
EC
Hex.12 M5×0.8
15
30
10
ø5.4
ø7.5ø6.5
510
øD
CE
Hex.12
Fixed type / Direct mount / Side port / Push-in fitting / Holder for Soft ・ Soft bellows Series
Fixed type / Direct mount / Side port / Barb fitting / Holder for Soft ・ Soft bellows Series
Unit:mm
Model codeTube O.D.
øDE
Tube endC
Connection config. code
VPHE-T15-180J 1.814.7 8.4
-T15VPHE-T15-2J 2VPHE-T15-3J 3
18.5 10.9VPHE-T15-4J7 4VPHE-T15-6J7 6 20.4 11.7VPHE-T40-180J 1.8
14.7 8.4
-T40VPHE-T40-2J 2VPHE-T40-3J 3
18.5 10.9VPHE-T40-4J7 4VPHE-T40-6J7 6 20.4 11.7※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec.
is available for model codes with 7 in the table above.
Unit:mm
Model codeTube I.D.
øDE C
Connection config. code
VPHE-T15-3B7 2 14.4 6-T15VPHE-T15-4B7 2.5
15.9 7VPHE-T15-6B7 4VPHE-T40-3B7 2 14.4 6
-T40VPHE-T40-4B7 2.515.9 7
VPHE-T40-6B7 4※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).
RoHS Compliant Copper alloy free available CAD (2D&3D)
RoHS Compliant Copper alloy free available CAD (2D&3D)
■ Dimensions of Fixed type holder for Soft / Soft bellows series
1161
Vacuum Pad SeriesVacuum Pad Holder Only
VPHE
VPHE-T15-M57 VPHE-T40-M57
ø8.5深さ
0.1
ø8.7
5
13
22.5
82.
52 ø5.2
Hex.12 M5×0.8
ø8.5深さ
0.1
30
10 15
5
ø5.4
ø7.5ø6.5
510
Hex.12 M5×0.8
Fixed type / Direct mount / Side port / Female thread / Holder for Soft ・ Soft bellows Series
Unit:mm
Model codeConnectionconfig. code
VPHE-T15-M57 -T15
VPHE-T40-M57 -T40
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).
RoHS Compliant Copper alloy free available CAD (2D&3D)
VPHEW
VPHE-T1547 VPHE-T4047
2.5
2
ø8.7
13
22.5
8
ø5.2 2-øD
2-C2-E
Hex.12
M5×0.8
15
30
10
ø5.4
ø7.5ø6.5
510 2-øD
2-C2-E
Hex.12 M5×0.8
Fixed type / Direct mount / Dual side port / Push-in fitting / Holder for Soft ・ Soft bellows Series
Unit:mm
Model codeTube O.D.
øDE
Tube endC
Connection config. code
VPHEW-T15-180J 1.814.7 8.4
-T15VPHEW-T15-2J 2VPHEW-T15-3J 3
18.5 10.9VPHEW-T15-4J7 4VPHEW-T15-6J7 6 20.4 11.7VPHEW-T40-180J 1.8
14.7 8.4
-T40VPHEW-T40-2J 2VPHEW-T40-3J 3
18.5 10.9VPHEW-T40-4J7 4VPHEW-T40-6J7 6 20.4 11.7※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec.
is available for model codes with 7 in the table above.
RoHS Compliant Copper alloy free available CAD (2D&3D)
1162
https://en.pisco.co.jp/
VPHEW
VPHEW-T1547 VPHEW-T4047
M5×0.8
2.5
2
ø8.7
13
22.5
8
ø5.2 2-øD
2-E2-CHex.12
M5×0.8
15
30
10
ø5.4
ø7.5ø6.5
510 2-øD
2-C2-E
Hex.12
Fixed type / Direct mount / Dual side port / Barb fitting / Holder for Soft ・ Soft bellows Series
Unit:mm
Model codeTube I.D.
øDE C
Connection config. code
VPHEW-T15-3B7 2 14.4 6-T15VPHEW-T15-4B7 2.5
15.9 7VPHEW-T15-6B7 4VPHEW-T40-3B7 2 14.4 6
-T40VPHEW-T40-4B7 2.515.9 7
VPHEW-T40-6B7 4※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).
RoHS Compliant Copper alloy free available CAD (2D&3D)
VPHEW
VPHEW-T15-M57 VPHEW-T40-M57
2-ø8
.5深さ
0.1
ø8.7
13
22.5
82.
52 ø5.2
Hex.12 M5×0.8
2-ø8
.5深さ
0.1
30
10 15
ø5.4
ø7.5ø6.5
510
Hex.12 M5×0.8
Fixed type / Direct mount / Dual side port / Female thread / Holder for Soft ・ Soft bellows Series
Unit:mm
Model codeConnectionconfig. code
VPHEW-T15-M57 -T15
VPHEW-T40-M57 -T40
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).
RoHS Compliant Copper alloy free available CAD (2D&3D)
1163
Vacuum Pad SeriesVacuum Pad Holder Only
VPHC
VPHC-T15-947 VPHC-T40-947
14.2
22.
5
ø8.7
C
øD49
.2 2-4
ø5.2
9
0.7
20
2-Hex.19
M16×1 M16×1
C
øD
B
2-4
2019
.7 0.7
10 5
ø5.4
ø7.5ø6.5
9
2-Hex.19
Spring type / Top port / Push-in fitting / Holder for Soft ・ Soft bellows Series
Unit:mm
Model codeTube O.D.
øDB
Tube endC
Spring force(N)
Connection config. code
VPHC-T15-9-180J 1.845.4 8.4
0.9 � 2.7 -T15VPHC-T15-9-2J 2VPHC-T15-9-3J 3
49.2 10.9VPHC-T15-9-4J7 4VPHC-T15-9-6J7 6 50.6 11.7VPHC-T40-9-180J 1.8
50.9 8.4
0.9 � 2.7 -T40VPHC-T40-9-2J 2VPHC-T40-9-3J 3
54.7 10.9VPHC-T40-9-4J7 4VPHC-T40-9-6J7 6 56.1 11.7※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec.
is available for model codes with 7 in the table above.※ .Tightening torque for fixing a pad holder is 2~3N·m.
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)9
■ Dimensions of Spring type holder for Soft / Soft bellows series
1164
https://en.pisco.co.jp/
VPHC
VPHC
VPHC-T15-947 VPHC-T40-947
14.2
22.
5
ø8.7
46.6
C
øD
2-4
ø5.2
9
0.7
20
2-Hex.19
M16×1 M16×1
øD
C
B
2-4
2019
.7 0.7
10 5
ø5.4
ø7.5ø6.5
9
2-Hex.19
VPHC-T15-9-M57 VPHC-T40-9-M57M5×0.8
M16×1
ø8.7
5
2-4
2.5
2 ø5.2
9
0.7
36.5
14.2
20
2-Hex.19
M5×0.8
M16×1
2-4
4220
19.7 0.
710 5
ø5.4
ø7.5ø6.5
59
2-Hex.19
Spring type / Top port / Barb fitting / Holder for Soft ・ Soft bellows Series
Spring type / Top port / Female thread / Holder for Soft ・ Soft bellows Series
Unit:mm
Model codeTube I.D.
øDB C
Spring force(N)
Connection config. code
VPHC-T15-9-3B7 2 45.1 60.9 � 2.7 -T15VPHC-T15-9-4B7 2.5
46.6 7VPHC-T15-9-6B7 4VPHC-T40-9-3B7 2 50.6 6
0.9 � 2.7 -T40VPHC-T40-9-4B7 2.552.1 7
VPHC-T40-9-6B7 4※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).※ .Tightening torque for fixing a pad holder is 2~3N·m.
Unit:mm
Model codeSpring force
(N)Connectionconfig. code
VPHC-T15-9-M57 0.9 � 2.7 -T15
VPHC-T40-9-M57 0.9 � 2.7 -T40
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).
※ .Tightening torque for fixing a pad holder is 2~3N·m.
RoHS Compliant Copper alloy free available CAD (2D&3D)
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)9
Stroke (mm)9
1165
Vacuum Pad SeriesVacuum Pad Holder Only
VPHD
VPHD-T15-547 VPHD-T40-547ø18
26.7
22.
5
ø8.717
.7378.
2 4(1
.8)
5.2
ø5.2øD
CE
2-Hex.13
Hex.12
M8×1 ø18
17.7
32.2
ø5.4
10 5
ø7.5ø6.5
42.5
8.2 4
(1.8
)5.
2
EC
øD
2-Hex.13
Hex.12
M8×1
Spring type / Side port / Push-in fitting / Holder for Soft ・ Soft bellows Series
Unit:mm
Model codeTube O.D.
øDE
Tube endC
Spring force(N)
Connection config. code
VPHD-T15-5-180J 1.814.7 8.4
1.6 � 2.9 -T15VPHD-T15-5-2J 2VPHD-T15-5-3J 3
18.5 10.9VPHD-T15-5-4J7 4VPHD-T15-5-6J7 6 20.4 11.7VPHD-T40-5-180J 1.8
14.7 8.4
1.6 � 2.9 -T40VPHD-T40-5-2J 2VPHD-T40-5-3J 3
18.5 10.9VPHD-T40-5-4J7 4VPHD-T40-5-6J7 6 20.4 11.7※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec.
is available for model codes with 7 in the table above.※ .Tightening torque for fixing a pad holder is 1.8~2.4N·m.
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)5.2
1166
https://en.pisco.co.jp/
VPHD
VPHD
VPHD-T15-547 VPHD-T40-547ø18
26.7
22.
5
ø8.7
17.737
8.2 4
(1.8
)5.
2
ø5.2
øD
CE
2-Hex.13
Hex.12
M8×1 ø18
17.7
32.2
ø5.4
10 5
ø7.5ø6.5
42.5
8.2 4
(1.8
)5.
2 C
øD
E
2-Hex.13
Hex.12
M8×1
VPHD-T15-5-M57 VPHD-T40-5-M57ø18
ø8.5深さ
0.1
ø8.7
17.7
5
378.
2 4(1
.8)
26.7 5.
22.
52 ø5.2
2-Hex.13M5×0.8
Hex.12
M8×1 ø18
ø8.5深さ
0.1
32.2
ø5.4
10 5
ø7.5ø6.5
42.5 17.7
5
8.2 4
(1.8
)5.
2
2-Hex.13M5×0.8
Hex.12
M8×1
Spring type / Side port / Barb fitting / Holder for Soft ・ Soft bellows Series
Spring type / Side port / Female thread / Holder for Soft ・ Soft bellows Series
Unit:mm
Model codeTube I.D.
øDE C
Spring force(N)
Connection config. code
VPHD-T15-5-3B7 2 14.4 61.6 � 2.9 -T15VPHD-T15-5-4B7 2.5
15.9 7VPHD-T15-5-6B7 4VPHD-T40-5-3B7 2 14.4 6
1.6 � 2.9 -T40VPHD-T40-5-4B7 2.515.9 7
VPHD-T40-5-6B7 4※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).※ .Tightening torque for fixing a pad holder is 1.8~2.43N·m.
Unit:mm
Model codeSpring force
(N)Connectionconfig. code
VPHD-T15-5-M57 1.6 � 2.9 -T15
VPHD-T40-5-M57 1.6 � 2.9 -T40
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).
※ .Tightening torque for fixing a pad holder is 1.8~2.4N·m.
RoHS Compliant Copper alloy free available CAD (2D&3D)
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)5.2
Stroke (mm)5.2
1167
Vacuum Pad SeriesVacuum Pad Holder Only
VPHDW
VPHDW-T15-547 VPHDW-T40-547ø18
ø8.717
.7
ø5.2 2-øD
2-C2-E
2-Hex.13
Hex.12
M8×126
.7
22.
5
378.
2 4(1
.8)
5.2
ø18
17.7
32.2
ø5.4
10 5
ø7.5ø6.5
42.5
8.2 4
(1.8
)5.
2
2-E2-C
2-øD
2-Hex.13
Hex.12
M8×1
Spring type / Dual side port / Push-in fitting / Holder for Soft ・ Soft bellows Series
Unit:mm
Model codeTube O.D.
øDE
Tube endC
Spring force(N)
Connection config. code
VPHDW-T15-5-180J 1.814.7 8.4
1.6 � 2.9 -T15VPHDW-T15-5-2J 2VPHDW-T15-5-3J 3
18.5 10.9VPHDW-T15-5-4J7 4VPHDW-T15-5-6J7 6 20.4 11.7VPHDW-T40-5-180J 1.8
14.7 8.4
1.6 � 2.9 -T40VPHDW-T40-5-2J 2VPHDW-T40-5-3J 3
18.5 10.9VPHDW-T40-5-4J7 4VPHDW-T40-5-6J7 6 20.4 11.7※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec.
is available for model codes with 7 in the table above.※ .Tightening torque for fixing a pad holder is 1.8~2.4N·m.
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)5.2
1168
https://en.pisco.co.jp/
VPHDW
VPHDW
VPHDW-T15-547 VPHDW-T40-547ø18
26.7
22.
5
ø8.7
17.737
8.2 4
(1.8
)5.
2
ø5.2 2-øD
2-C2-E
2-Hex.13
Hex.12
M8×1 ø18
17.7
32.2
ø5.4
10 5
ø7.5ø6.5
42.5
8.2 4
(1.8
)5.
2 2-C
2-øD
2-E
2-Hex.13
Hex.12
M8×1
VPHDW-T15-5-M57 VPHDW-T40-5-M57ø18
2-ø8
.5深さ
0.1
ø8.7
17.737
8.2 4
(1.8
)26
.7 5.2
2.5
2 ø5.2
2-Hex.13M5×0.8
Hex.12
M8×1 ø18
2-ø8
.5深さ
0.1
32.2
ø5.4
10 5
ø7.5ø6.5
42.5 17.7
8.2 4
(1.8
)5.
2
2-Hex.13M5×0.8
Hex.12
M8×1
Spring type / Dual side port / Barb fitting / Holder for Soft ・ Soft bellows Series
Spring type / Dual side port / Female thread / Holder for Soft ・ Soft bellows Series
Unit:mm
Model codeTube I.D.
øDE C
Spring force(N)
Connection config. code
VPHDW-T15-5-3B7 2 14.4 61.6 � 2.9 -T15VPHDW-T15-5-4B7 2.5
15.9 7VPHDW-T15-5-6B7 4VPHDW-T40-5-3B7 2 14.4 6
1.6 � 2.9 -T40VPHDW-T40-5-4B7 2.515.9 7
VPHDW-T40-5-6B7 4※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).※ .Tightening torque for fixing a pad holder is 1.8~2.43N·m.
Unit:mm
Model codeSpring force
(N)Connectionconfig. code
VPHDW-T15-5-M57 1.6 � 2.9 -T15
VPHDW-T40-5-M57 1.6 � 2.9 -T40
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).
※ .Tightening torque for fixing a pad holder is 1.8~2.4N·m.
RoHS Compliant Copper alloy free available CAD (2D&3D)
RoHS Compliant Copper alloy free available CAD (2D&3D)
Stroke (mm)5.2
Stroke (mm)5.2
1169
Vacuum Pad SeriesVacuum Pad Holder Only
VPA
VPE
VPE
L
92
C
B7.
62-
Tø18.4
øD
ø16.5
M
Hex.24
2-H
VPA-PB154
VPE-PB15-M5VPE-PB15-M6
VPE-PB15-M8VPE-PB15-M14
M
Hex.24
B
ø18.4
ø16.5
7.6 0.5
18.6
92
GasketM
Hex.24
B
ø18.4
ø16.5
7.6
92
O-ring
G
H
B 7.6
92
ø18.4
ø16.5
O-ring
VPE-PB154
Fixed type / Top port / Push-in fitting / Holder for Vacuum pad for packaging bag Series
Fixed type / Direct mount / Metric male thread / Holder for Vacuum pad for packaging bag Series
Fixed type / Direct mount / Parallel pipe male thread / Holder for Vacuum pad for packaging bag Series
Unit:mm
Model codeTube O.D.
øDThread
MB L
Tube endC
THex.
HConnectionconfig. code
VPA-PB15-6J 6 M14 × 1 43.6 20.5 174
17
-PB15VPA-PB15-8J 8 M16 × 1 45.1 21 18.2 19VPA-PB15-10J 10 M20 × 1 48 22.5 20.7 5 24VPA-PB15-12J 12 M22 × 1 52.3 25.5 23.3 6 27※ .Tightening torque for fixing a pad holder is as following. Tube O.D.:ø6, ø8mm▶18~21N·m.
Tube O.D.:ø10, ø12mm▶19~21N·m.
Unit:mm
Model code M B Connection config. code
VPE-PB15-M5 M5 × 0.8 21.4
-PB15VPE-PB15-M6 M6 × 1 22.4VPE-PB15-M8 M8 × 1 22.6VPE-PB15-M14 M14 × 1 24.6
Unit:mm
Model code G BHex.
HConnection config.
codeVPE-PB15-G1 G1/8A 21.9
24-PB15
VPE-PB15-G2 G1/4A 23VPE-PB15-G3 G3/8A 24.5VPE-PB15-G4 G1/2A 25 27
RoHS Compliant CAD (2D&3D)
RoHS Compliant CAD (2D&3D)
RoHS Compliant CAD (2D&3D)
■ Dimensions of Fixed type holder for Vacuum pad for packaging bag sereies
1170
https://en.pisco.co.jp/
VPA
VPA-E1047 VPA-E2047
C
øD
ø12
22
1.5
23.5
B 1.5
ø9
ø5ø8
ø3
ø3.2
12
2820
4-R15
B
C
øD
ø10ø15
ø12
22
1.5
23.5
1.5
ø9
ø3
ø3.2
122820
4-R1
5
Screwed type / Top port / Push-in fitting / Holder for Oval Series
Unit:mm
Model codeTube O.D.
øDB
Tube endC
Connection config. code
VPA-E10-180J 1.835.8 8.4
-E10VPA-E10-2J 2VPA-E10-3J 3
39.6 10.9VPA-E10-4J7 4VPA-E10-6J7 6 41 11.7VPA-E20-180J 1.8
35.8 8.4
-E20VPA-E20-2J 2VPA-E20-3J 3
39.6 10.9VPA-E20-4J7 4VPA-E20-6J7 6 41 11.7※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec.
is available for model codes with 7 in the table above.
RoHS Compliant Copper alloy free available CAD (2D&3D)
■ Dimensions of Screwed type holder for Oval sereies
1171
Vacuum Pad SeriesVacuum Pad Holder Only
VPA
VPA
VPA-E1047 VPA-E2047øD
C
B
ø12
221.
523
.51.
5
ø9
ø5ø8
ø3
ø3.2
12
2820
4-R15
øD
B
C
ø10ø15
ø12
22
1.5
23.5
1.5
ø9
ø3
ø3.2
12
2820
4-R1
5
VPA-E10-M57 VPA-E20-M57ø12ø9
6
27
22
1.5
23.5
1.5
ø9
ø5ø8
ø3
M5×0.8
ø3.2
12
2820
4-R1
5
ø9
6
ø10ø15
ø12
27
22
1.5
23.5
1.5
ø9
ø3
M5×0.8
ø3.2
12
2820
4-R1
5
Screwed type / Top port / Barb fitting / Holder for Oval Series
Screwed type / Top port / Female thread / Holder for Oval Series
Unit:mm
Model codeTube I.D.
øDB C
Connection config. code
VPA-E10-3B7 2 35.5 6-E10VPA-E10-4B7 2.5
37 7VPA-E10-6B7 4VPA-E20-3B7 2 35.5 6
-E20VPA-E20-4B7 2.537 7
VPA-E20-6B7 4※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).
Unit:mm
Model codeConnectionconfig. code
VPA-E10-M57 -E10
VPA-E20-M57 -E20
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).
RoHS Compliant Copper alloy free available CAD (2D&3D)
RoHS Compliant Copper alloy free available CAD (2D&3D)
1172
https://en.pisco.co.jp/
VPB
VPB-E1047 VPB-E2047
øD
C 20
34.5
1.5
32.5
ø12
ø9
22
1.5
ø5ø8
ø3
2-ø3.2
12
2820
E5
4-R1
C
øD20
34.5
32.5
1.5 ø9
ø12
ø10ø15
22
1.5
ø3
E
2-ø3.2
122820
5
4-R1
Screwed type / Side port / Push-in fitting / Holder for Oval Series
Unit:mm
Model codeTube O.D.
øDE
Tube endC
Connection config. code
VPB-E10-180J 1.816.3 8.4
-E10VPB-E10-2J 2VPB-E10-3J 3
20.1 10.9VPB-E10-4J7 4VPB-E10-6J7 6 21.5 11.7VPB-E20-180J 1.8
16.3 8.4
-E20VPB-E20-2J 2VPB-E20-3J 3
20.1 10.9VPB-E20-4J7 4VPB-E20-6J7 6 21.5 11.7※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts). -S3 spec.
is available for model codes with 7 in the table above.
RoHS Compliant Copper alloy free available CAD (2D&3D)
1173
Vacuum Pad SeriesVacuum Pad Holder Only
VPB
VPB
VPB-E1047 VPB-E2047
C
øD20
34.5
1.5
32.5
ø12
ø9
22
1.5
ø5ø8
ø3
E
2-ø3.2
12
2820
5
4-R1
øD
C 20
34.5
32.5
1.5 ø9
ø12
ø10ø15
22
1.5
ø3
E
2-ø3.2
12
2820
5
4-R1
VPB-E10-M57 VPB-E20-M57
ø9
7.5
20
34.5
1.5
32.5
ø12
ø9
6
22
1.5
ø5ø8
ø3M5×0.8
2-ø3.2
12
2820
5
4-R1
6
ø920
7.5
34.5
32.5
1.5 ø9
ø12
ø10ø15
22
1.5
ø3M5×0.8
2-ø3.2
12
2820
5
4-R1
Screwed type / Side port / Barb fitting / Holder for Oval Series
Screwed type / Side port / Female thread / Holder for Oval Series
Unit:mm
Model codeTube I.D.
øDE C
Connection config. code
VPB-E10-3B7 2 16 6-E10VPB-E10-4B7 2.5
17.5 7VPB-E10-6B7 4VPB-E20-3B7 2 16 6
-E20VPB-E20-4B7 2.517.5 7
VPB-E20-6B7 4※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).
Unit:mm
Model codeConnectionconfig. code
VPB-E10-M57 -E10
VPB-E20-M57 -E20
※ .7: Replaced with "-S3" for -S3 spec. (Copper alloy free material for metal parts and FKM or HNBR for sealing parts).
RoHS Compliant Copper alloy free available CAD (2D&3D)
RoHS Compliant Copper alloy free available CAD (2D&3D)
Vacuum Pad SeriesVacuum Pad
477
Vacuum Pad
Common Safety Instructions for Vacuum Pads
Warning
Before selecting or using PISCO products, read the following instructions. Read the detailed instructions for individual series.
1.Take safety measures in advance where a dropping work-piece can cause danger.2.Make sure to install a vacuum pad holder securely. Looseness may cause trouble.3.Pay special attention to the work conveyance by screwed vacuum pads, accompanied by
rotary movement. There is a possibility of troubles due to the looseness of screws from the rotary movement.
4.There is a possibility of troubles due to the leakage of vacuum system, clogging, vacuum pad abrasion, crack, deterioration, the galling of slider part in the holder and the looseness in joints. Carry out maintenance inspection periodically.
5.When a work-piece is conveyed by a vacuum pad, consider the acceleration, impacts and wind pressure. Otherwise, the work-piece may drop during conveyance.
Caution1.Thoroughly read and understand the theoretical suction force in this catalog before selecting diameter, Qty and
suction place of vacuum pads. Select vacuum pads with enough margin in suction force.2.The product incorporating NBR as seal rubber material has a risk of malfunction caused by ozone crack. Ozone
exists in high concentrations in static elimination air, clean-room, and near the high-voltage motors, etc. As a countermeasure, material change from NBR to HNBR or FKM is necessary. Consult with Pisco for more information.
3.Select the material of vacuum pad in accordance with use environment and ease of use, referring to "Selecting Method".4.Select the suitable pad shape (type) in accordance with a work-piece and its shape, referring to "Characteristics of Pad
Material".5.Select spring-holder type when work-pieces have different heights or are weak against an external force. Select
the suitable holder type, referring to spring force and spring length in the catalog.6.Since spring-holder type has a sliding action, minimize the transverse load. Otherwise, the life time of the holder
can be reduced or malfunction of the holder can occur.7.In replacing vacuum pads, check the structure of holders and pads in the catalog and tighten the hexagonal-
column of the holder with a proper tool, referring to the following tightening torque.● Table. tightening torque
Vacuum pad holder Standard MiniPad screw size (mm) Tightening torque (N·m)
M4×0.7 0.5 ~ 1.0 0.9 ~ 1.1M6×1 2 ~ 2.7
M10×1.5 5 ~ 7 –M20×2 9 ~ 10 –
8.In replacing the adapters of Soft / Soft Bellows Series, check the structure of holders, pad and adapters and tighten the hexagonal-column of the holder with a proper tool, referring to the following tightening torque.● Table. tightening torque
Pad screw size (mm) Tightening torque (N·m)M4×0.7 0.7 ~ 0.8M6×1 1.5 ~ 2.0
478
https://en.pisco.co.jp/Vacuum pad
9.In installing vacuum pad holders of general and small type with bulkhead, check the structure and tighten the hexagonal-column of the holder with a proper tool, referring to the following tightening torque.
Vacuum pad holder Standard Mini
Vacuum pad holder type VPA
VPC, VPD,VPF,
VPHC,VPHD,
VPHDW
VPE VPMA VPMC,VPMD VPME
Bulkhead nut size (mm) Tightening torque (N·m)M3×0.5 — — 0.7 — — 0.7M4×0.5 — — — 1 ~ 1.2 — —M4×0.7 1 ~ 1.2 — — — — —M5×0.5 1.5 ~ 2 — — 1.5 ~ 2 — —M5×0.8 — — 1 ~ 1.5 — — 1 ~ 1.5
M6×0.75 2 ~ 3 — — 2 ~ 3 —M8×0.75 2.5 ~ 3.5 1.8 ~ 2.4 — 2.5 ~ 3.5 —
M8×1 — 1.8 ~ 2.4 — — — —M10×1 5 ~ 7 4.5 ~ 6 — 5 ~ 7 4 ~ 6 —M12×1 12 ~ 14 8 ~ 10 — — — —M14×1 18 ~ 21 4.5 ~ 6 — — — —M16×1 18 ~ 21(※) 2 ~ 3 — — — —M20×1 19 ~ 21 — — — — —M22×1 19 ~ 21(※) 16 ~ 20 — — — —M24×2 40 ~ 50 — — — — —M30×2 — 42 ~ 54 — — — —
※Values for Vacuum pad holder for Packaging bag series. 10.In replacing vacuum pad rubbers of Standard Series ø80, ø100mm, ø150mm, ø200mm and Bellows Series
ø80mm, ø100mm, check the structure of holders and pads and tighten the hexagonal-column of the holder with a proper tool, referring to the following tightening torque.
● Table. tightening torquePad screw size (mm) Tightening torque (N·m)
M4×0.70.5 ~ 0.7
M5×0.8
11.Check the structure of vacuum pad in the catalog before replacing a filter element.12.Refer to "Common Safety Instructions for Fittings" for handing fitting joint parts.13.In installing spring-holder type, do not hold the shaft A with a spanner.
In replacing vacuum pad, hold the hexagonal-column of the shaft with a spanner. If the keyway B is deformed, there is a possibility of malfunction.
14.Excessive tightening of a fixing nut may deform the bulkhead part and result in malfunction of the keyway.
15.As the nature of rubber, powdery component like additives may come out on 15.As the nature of rubber, powdery component like additives may come out on the surface of a vacuum pad as time elapses.the surface of a vacuum pad as time elapses. B }A
Vacuum Pad SeriesVacuum Pad
479
Vacuum Pad0
4
2
0
10
18
16
14
12
8
6
20
20 40 60 80 100
ø15
ø10
ø6
ø8
Vacuum level (–kPa)
Theo
retic
al s
uctio
n fo
rce
(N)
Pad
dia.
(mm
)
ø4ø3ø2
0
500
0
1000
2000
3500
3000
1500
2500
20 40 60 80 100
ø200
ø150
ø100
ø80
ø60
Vacuum level (–kPa)
Theo
retic
al s
uctio
n fo
rce
(N)
Pad
dia.
(mm
)
0
100
50
0
150
200
250
20 40 60 80 100
ø50
ø40
ø30
ø25
ø20
Vacuum level (–kPa)
Theo
retic
al s
uctio
n fo
rce
(N)
Pad
dia.
(mm
)
Pad dia.:ø2mm ~ ø15mm Pad dia.:ø20mm ~ ø50mm
Pad dia.:ø60mm ~ ø200mm
0
0.2
0
0.4
0.8
1.4
1.2
0.6
1.0
20 40 60 80 100
ø3
ø4
ø2
ø1.5
ø1ø0.7
Vacuum level (–kPa)
Theo
retic
al s
uctio
n fo
rce
(N)
Pad
dia.
(mm
)
Pad dia. (Small):ø0.7mm ~ ø4mm
Vacuum Pad Selection GuideSelection Guide 1
▲
The theoretical suction force is determined from pad area and vacuum level. Calculated value is for reference only, so carry out the evaluation under an actual operating condition. The theoretical suction force is calculated under a static condition. Obtain an enough margin, considering the weight of a work-piece and acceleration of lifting, pause and rotary movement. Enough room is needed in deciding a number of pads and arrangement position.
① Calculation by formula
W = C × P × 10.13 × f −
101
*1.Refer to the following chart for Sponge Series.(Internal diameter is used for calculation)*2.Refer to the following chart for Flat Series.(Pad grooves are used for calculation)*3.As for Bellows, Multi-Bellows, Soft, Soft Bellows and Ultrathin Series, their theoretical suction force may
exceed the strength of pad itself, depending on the vacuum level. Carry out the evaluation under an actual operating condition.
Horizontal lifting
Vertical lifting
W:Suction force(N) C :Pad area(cm²) P :Vacuum level −kPa f : Safety factor Horizontal lifting (refer to the right fig.)
▲
1/4 Vertical lifting (refer to the right fig.)
▲
1/8
② Chart of the theoretical suction force <Add safety factor to values from the chart>Standard / Bellows / Multi-bellows / Soft / Soft bellows / Skidproof / Ultrathin / Mark-free (*)
Select the diameter of vacuum pad from the formula ① and chart of the theoretical suction force ②
*Some sizes are not available for some pad series. Refer to the following size list. ● : indicates that pad size is available
Pad type Standard Bellows Multi-bellows Soft Soft bellows Skidproof Ultra thin Mark-free
Pad dia. (mm
)
ø0.7~ø3 ● ー ー ー ー ー ー ーø4 ● ー ー ● ー ー ー ーø6 ● ● ー ● ● ー ー ーø8 ● ● ー ● ● ー ● ーø10 ● ● ● ● ● ● ● ●ø15 ● ● ー ● ● ー ● ーø20 ● ● ● ● ● ● ● ●ø25 ● ● ー ー ー ー ー ーø30 ● ● ● ● ー ● ー ●ø40 ● ● ● ● ー ● ー ーø50 ● ● ● ー ー ● ー ーø60 ● ● ー ー ー ー ー ーø80 ● ● ー ー ー ー ー ーø100 ● ● ー ー ー ー ー ーø150 ● ー ー ー ー ー ー ーø200 ● ー ー ー ー ー ー ー
480
https://en.pisco.co.jp/Vacuum pad
0
300
250
200
150
100
50
0
350
400
450
20 40 60 80 100
ø100
ø50
ø70
ø10 ø15ø20ø30 ø25ø35
Vacuum level (–kPa)
Theo
retic
al s
uctio
n fo
rce
(N)
Pad
dia.
(mm
)
Pad dia.:ø10mm ~ ø100mm
0
8
4
0
12
16
20
6
2
10
14
18
20 40 60 80 100
ø30
ø25
ø20
ø15
ø10
Vacuum level (–kPa)
Theo
retic
al s
uctio
n fo
rce
(N)
Pad
dia.
(mm
)
0
15
10
5
0
25
20
20 40 60 80 100
8×30
6×30
5×30,8×20
4×306×205×20
4×20
6×10
Vacuum level (–kPa)
Theo
retic
al s
uctio
n fo
rce
(N)
Pad
size
(mm
)
4×103.5×7
2×4
Pad size:2×4mm, 3.5×7mm,□×10mm, □×20mm, □×30mm
5×10
Sponge pad Flat pad Oval padPad dia.:ø10mm ~ ø30mmPad dia.:ø10mm ~ ø100mm Pad size:2×4mm ~ 8×30mm
Vacuum Pad SeriesVacuum Pad
481
Vacuum Pad
ød
øS
Selection Guide 2
▲
Please select suitable pads for your application from the following.
Standard Series Bellows / Multi-bellows Series
Ultrathin Series
Skidproof Series
Thick & flat work-piece Round fruit or ball (*1)
Oval Series
Soft / Soft bellows Series
Food package
Long work-piece (e.g. circuit board and semiconductor product)
Taking out molded parts / Fragile work-piece Greasy work-piece such as pressed parts
Thin work-piece such as paper or plastic bag
General type
Deep type
*1.The table below is a reference for the vacuum pad deep type and the size of round work-piece.
Spherical dia.:S (mm) ø20 ø30 ø40 ø50 ø80 ø100 ø120 ø160 ø200 Pad size:d (mm) ø15 ø20 ø25 ø30 ø40 ø50 ø60 ø80 ø100
*2.Refer to the previous page for pad dia. selection except deep type. Refer to the next page for the characteristics of pad materials.
Sponge Series
Exterior wall panel, pebble, seashell
Mark-free Series
Flat Series
LCD glass / in Painting process / semiconductor manufacturing device
Thin work-piece such as sheet or plastic bag
Small work-piece or semiconductor manufacturing device
Small type
Select a vacuum pad type according to a work-piece.
482
https://en.pisco.co.jp/Vacuum pad
Selection Guide 2
▲
Please select the suitable material from the table.
Legend ◎:Best○:Suitable △:Good×:NG
*1.Material code "NH" is only available for Skidproof Series.*2.It does not apply to pad size: 4×30mm.Note 1).The above "Physical Properties" shows the data of general synthetic rubbers.Note 2).The highest / lowest operating temp. is for momentary usage. Carry out durability evaluation in case of continuous usage under the highest / lowest operating temp.
ItemPad material
Nitrilerubber
NBR Suited
for the foodsanitation
act. (Japan)
HNBRSiliconerubber
ConductiveSiliconerubber
Urethanerubber
Fluororubber
Fluorosiliconerubber
EPDM
ConductiveButadiene
rubber (Lowresistance
type)
ConductiveNBR (low
resistance)
Chloroprenerubber (For
Spongetype)
Siliconerubber(For
SpongeType)
Material codeN,
NH (*1)G HN S SE U F FS EP E NE – S
Application
CardboardPlywood
Metal plateFood-relatedOther general
work
CardboardPlywoodMetal plateFood-relatedOther general
workIn use undera low ozone
concentrationenvironment
SemiconductorsTaking out
molded partsThin work-piece
Food-related
CardboardPlywoodMetal plate
ChemicalenvironmentHigh temp.
work-pieces
Taking out molded parts
Application that
requires light-
resistant or ozoneproof
In use under the moisture
containing atmosphere
General pars of
semicon-ductors
Semi-conductors
Uneven work-piece
Uneven work-piece
Food-related
Pad color Black Gray Black Translucent Black Blue Gray Salmon Black Black Black Black Salmon
Select a vacuum pad material from an application..
Physical Properties
Surface hardness(Shore A)
Standard 50˚~80˚ 60˚~70˚ 50˚~70˚ 50˚ 60˚ 55˚~70˚ 60˚~70˚ − 50˚~70˚ 70˚ 60˚~70˚ − −Bellows 50˚ − 50˚ 50˚ 60˚ 55˚ 60˚ − 50˚ − 60˚ − −Multi-bellows 50˚ 50˚ 50˚ 50˚ − 55˚ 50˚ − 50˚ − 60˚ − −Oval 40˚~50˚ − 50˚ 40˚~50˚ 50˚~60˚ 55(̊*2)50(̊*2) − 50˚ 70˚ 70˚ − −Soft 40˚ − − 40˚ 60˚ − − 40˚ − − 50˚ − −Soft bellows 40˚ − 50˚ 40˚ − 55˚ − − 50˚ − 60˚ − −Skidproof 50˚ − − 50˚ − 55˚ 60˚ − − − 60˚ − −Ultrathin 40˚ − − 40˚ − 55˚ 50˚ 40˚ − − 60˚ − −Flat 60˚ − − 40˚ 40˚ 50˚ 50˚ − − − 60˚ − −
Highest operating temp. 110˚C 140˚C 180˚C 60˚C 230˚C 180˚C 150˚C 100˚C 110˚C 80˚C 180˚CLowest operating temp. -30˚C -30˚C -40˚C -20˚C -10˚C -50˚C -40˚C -50˚C -30˚C -45˚C -40˚CWeatherability △ ○ ◎ ○ ○ ○ ◎ ○ △ ○ ◎Ozone-proof × ○ ◎ ◎ ◎ ◎ ◎ × × ○ ◎Acid-resistance △ △ ○ × ◎ ○ ◎ △ △ △ ○Alkaline-resistance ○ ○ ◎ × × ◎ ◎ ○ ○ ◎ ◎Oilresistance
(Gasoline oil) ◎ ◎ △ ◎ ◎ △ × × ◎ × △(Benzene/toluene) △ × △ △ ◎ △ × × △ △ △
Volume resistance − − − Max. 10⁵Ω·cm − − − − Max. 200Ω·cm Max. 200Ω·cm − −
Vacuum Pad SeriesVacuum Pad
483
Vacuum Pad
To prevent dust from getting into the pad holder.Install a vacuum filter pad direct mounting type between a vacuum pad and a holder.
Work-piece
Vacuum air containing dust
Vacuum air from which dust wasremoved by a vacuum filter
Vacuum pad
Pad holder
Vacuum filterpad direct mounting type
Vacuum generator
To prevent dust from getting into the pad holder.Installing a fall prevention valve between a vacuum pad and a holder prevents the troubles like system break down, minimizing the vacuum drop of the whole system automatically by reducing suction flow of the part where the work-piece falls from the vacuum pad (within the range not causing any problem), or no work-piece is to be sucked.
Fall prevention valve
Pad holder
Vacuum pad Work-piece
Please select the suitable vacuum pad resin material from the table.
Legend ◎:Best○:Suitable△:Good×:NG
Note 1).The above "Physical Properties" shows the data of pad resin material only. The holder of Mark-free Series is not included.Note 2).The above "Physical Properties" shows the data of resin attachment only. The pad rubber is not included.Note 3). The above "Physical Properties" shows a general properties of resin materials and not a guaranteed value. Carry out the necessary
evaluation under an actual operating condition.Note 4). The highest / lowest operating temp. is for momentary usage. Carry out durability evaluation in case of continuous usage under the
highest / lowest operating temp.Note 5).Volume resistance is a representative value from the material manufacture, and not a guaranteed value.
Item
Pad material PEEK POM Conductive PEEK
Materialcode
Mark free series K M KEResin attachment for Bellows series
-QK -QM -QKE
ApplicationManufacturing machine for
liquid crystal / semiconductorGeneral production lineFood-related machinePackaging machine
Manufacturing machine for liquid crystal / semiconductor
Electronic componentsPad color Natural (ivory) White Black
Physical Properties
Highest operating temp. 250˚C 95˚C 250˚CLowest operating temp. -50˚C -60˚C -50˚CWeatherability ◎ × ◎Acid-resistance ◎ × ◎Alkaline-resistance ◎ △ ◎Self-lubricity ○ ◎ ○Abrasion-resistance ◎ ◎ ◎Volume resistance − − 10⁵~10⁶Ω·cm
○ × ○ × ○
▲Vacuum source
15°
484
https://en.pisco.co.jp/Vacuum pad
Reference Guide for Vacuum PadImpact on pad
Avoid an impact or a large force on a vacuum pad, when it is pressed against a work-piece. It may cause deformation, crack or abrasion at an early stage of use. Adjust the pad position so that the lip of pad touches lightly on a work-piece. Especially a small type of vacuum pad should be positioned precisely.
Porous or perforated work-pieceSince the suction of a porous work-piece causes a drop of suction force, select the proper specifications of vacuum system and secure a larger effective crosssection area of the piping. Selecting a small type of vacuum pad is one of solutions to reduce the air leakage.
Large and wide flat plate work-pieceWhen lifting large size of glass board or circuit board, work-piece may bend by the lifting acceleration or the self-weight. Select a proper size of pad and positioning, considering an enough margin of suction force.
Soft work-piece Work-piece with different heightsSelect Long Stroke holders for work-pieces having different heights, or piled-up work-pieces. Its stroke can absorb the difference in height.
Inclined work-pieceSelect Free Holder for an inclined work-piece.
Positioning within this range
Porous work-piece
Plastic bag, paper, etc.
Large size of glass board or circuit board
Inclined work-piece
Work-pieces havingdifferent heights
Large force by lifting
Plastic bag, paper bag
●Figure-1 ●Figure-2
Long Stroke holders
Free holderTwo selection of articulationangle: 0-15°/0-30°
Lifting work-piece, sucking the both side of itSince all vacuum pad holders are designed for horizontal lifting, consider the strength of holders and pads.
Work-piece
Lifting
Consider to reduce the stress against holders and pads by sucking the both sides of work-piece.
Vacuum pad
Pad holder
Conveyance with rotary movementWhen vacuum pad is fixed with a screw and has a rotary movement, the pad may drop due to the loosened screw. Pay special attention when the vacuum location of work-piece is off the center of work-piece gravity.
Safety factor (1/8) of vertical lifting needs to be app l ied in ro tary conveys or lateral movement
When soft work-pieces such as plastic bags, papers or thin boards are sucked, work-pieces can be deformed or shrunk by vacuum suction (Figure-1). Select smaller vacuum pads and reduce the vacuum pressure. Smaller vacuum pads are suitable for plastic bags and papers. When plastic / paper bags are opened by using vacuum pads, shift the center of two vacuum pads slightly in order to open them easily as Figure-2 shows.
■ Pad dia. list by pad type and material
Vacuum Pad SeriesVacuum Pad
485
Vacuum Pad
Pad material N:Nitrile rubber
Pad typeStandard
BellowsMulti-
BellowsSoft
Softbellows
Ultrathin FlatGeneral type Deep type Small type
Pad dia. (mm
)
ø0.7 ●ø1 ● ●
ø1.5 ●ø2 ● ●ø3 ● ●ø4 ● ● ●ø6 ● ● ● ●ø8 ● ● ● ● ●ø10 ● ● ● ● ● ● ●ø15 ● ● ● ● ● ● ●ø20 ● ● ● ● ● ● ● ●ø25 ● ● ● ●ø30 ● ● ● ● ● ●ø40 ● ● ● ● ●ø50 ● ● ● ●ø60 ● ● ●ø80 ● ● ●ø100 ● ● ●ø150 ●ø200 ●
Pad material S:Silicone rubber
Pad typeStandard
BellowsMulti-
BellowsSoft
Softbellows
Flat Skidproof Ultrathin SpongeGeneral type Deep type Small type
Pad dia. (mm
)
ø0.7 ●ø1 ● ●
ø1.5 ●ø2 ● ●ø3 ● ●ø4 ● ● ●ø6 ● ● ● ●ø8 ● ● ● ● ●
ø10 ● ● ● ● ● ● ● ● ●ø15 ● ● ● ● ● ● ● ●ø20 ● ● ● ● ● ● ● ● ● ●ø25 ● ● ● ● ●ø30 ● ● ● ● ● ● ● ●ø35 ●ø40 ● ● ● ● ● ●ø50 ● ● ● ● ● ●ø60 ● ● ●ø70 ●ø80 ● ● ●ø100 ● ● ● ●ø150 ●ø200 ●
● :Available
● :Available
486
https://en.pisco.co.jp/Vacuum pad
Pad material U:Urethane rubber
Pad typeStandard
BellowsMulti-
BellowsSoft bellows Skidproof Ultrathin Flat
General type Deep type Small type
Pad dia. (mm
)
ø0.7 ●ø1 ● ●
ø1.5 ●ø2 ● ●ø3 ● ●ø4 ● ●ø6 ● ● ●ø8 ● ● ● ●ø10 ● ● ● ● ● ● ●ø15 ● ● ● ● ● ●ø20 ● ● ● ● ● ● ● ●ø25 ● ● ● ●ø30 ● ● ● ● ● ●ø40 ● ● ● ● ●ø50 ● ● ● ● ●ø60 ● ● ●ø80 ● ● ●ø100 ● ● ●ø150 ●ø200 ●
Pad material F:Fluoro rubber G:NBR Suited for the food sanitation act. (Japan)
Pad typeStandard
Bellows Multi-
BellowsSkidproof Ultrathin Flat
Standard Multi-BellowsGeneral type Deep type Small type General type Deep type Small type
Pad dia. (mm
)
ø0.7 ● ●ø1 ● ● ● ●
ø1.5 ● ●ø2 ● ● ● ●ø3 ● ● ● ●ø4 ● ● ● ●ø6 ● ● ●ø8 ● ● ● ●ø10 ● ● ● ● ● ● ● ●ø15 ● ● ● ● ● ● ●ø20 ● ● ● ● ● ● ● ● ● ●ø25 ● ● ● ● ● ●ø30 ● ● ● ● ● ● ● ● ●ø40 ● ● ● ● ● ● ● ●ø50 ● ● ● ● ● ● ● ●ø60 ● ● ●ø80 ● ● ●ø100 ● ● ●ø150 ●ø200 ●
● :Available
● :Available
Vacuum Pad SeriesVacuum Pad
487
Vacuum Pad
Pad material SE:Conductive Silicone rubberE:Conductive Butadiene
rubber (Low resistance type)S:Chloroprene
rubberNH:Oilproof
NBR
Pad typeStandard
Bellows Soft FlatStandard
Sponge SkidproofGeneral type Small type General type Small type
Pad dia. (mm
)
ø0.7 ● ●ø1 ● ● ● ●
ø1.5 ● ●ø2 ● ● ● ●ø3 ● ● ● ●ø4 ● ● ● ● ●ø6 ● ● ● ●ø8 ● ● ● ●
ø10 ● ● ● ● ● ● ●ø15 ● ● ● ● ● ●ø20 ● ● ● ● ● ● ●ø25 ● ● ● ● ●ø30 ● ● ● ● ● ● ●ø35 ●ø40 ● ● ● ● ●ø50 ● ● ● ● ●ø60 ● ●ø70 ●ø80 ● ●ø100 ● ● ●ø150 ●ø200 ●
Pad material NE:Conductive NBR (low resistance)
Pad typeStandard Bellows
typeMulti-
BellowsSoft Soft bellows Skidproof Ultrathin Flat
General type Deep type Small type
Pad dia. (mm
)
ø0.7 ●ø1 ● ●
ø1.5 ●ø2 ● ●ø3 ● ●ø4 ● ● ●ø6 ● ● ● ●ø8 ● ● ● ● ●ø10 ● ● ● ● ● ● ● ●ø15 ● ● ● ● ● ● ●ø20 ● ● ● ● ● ● ● ● ●ø25 ● ● ● ●ø30 ● ● ● ● ● ● ●ø40 ● ● ● ● ● ●ø50 ● ● ● ● ●ø60 ● ● ●ø80 ● ●ø100 ● ● ●ø150 ●ø200 ●
● :Available
● :Available
488
https://en.pisco.co.jp/Vacuum pad
Pad material HN:HNBR EP:EPDM FS:Fluorosilicone rubber
Pad typeStandard
Bellows Multi-
BellowsSoft
bellowsStandard Bellows
typeMulti-
BellowsSoft
bellowsSoft Ultrathin
General type Deep type Small type General type Deep type Small type
Pad dia. (mm
)
ø0.7 ● ●ø1 ● ● ● ●
ø1.5 ● ●ø2 ● ● ● ●ø3 ● ● ● ●ø4 ● ● ● ● ●ø6 ● ● ● ● ● ● ●ø8 ● ● ● ● ● ● ● ●ø10 ● ● ● ● ● ● ● ● ● ●ø15 ● ● ● ● ● ● ● ● ● ●ø20 ● ● ● ● ● ● ● ● ● ● ● ●ø25 ● ● ● ● ● ●ø30 ● ● ● ● ● ● ● ● ●ø40 ● ● ● ● ● ● ● ● ●ø50 ● ● ● ● ● ● ● ●ø60 ● ● ● ● ● ●ø80 ● ● ● ● ● ●
ø100 ● ● ● ● ● ●ø150 ● ●ø200 ● ●
Pad materialN
Nitrile rubber
SSilicone rubber
UUrethane
rubber
FFluoro rubber
SEConductive
Silicone rubber
EConductive
Butadiene rubber(Low resistance type)
NEConductive NBR
(Low resistance type)
HNHNBR
EPEPDM
Pad type Oval
Pad material K:PEEK M:POM KE:Conductive PEEK Q2K:PEEK Q2M:POM Q2KE:Conductive PEEKPad type Mark free Resin attachment for Bellows series
Pad dia. (mm
)
ø10 ● ● ● ● ● ●ø15 ● ● ●ø20 ● ● ● ● ● ●ø25 ● ● ●ø30 ● ● ● ● ● ●
Pad dia. (mm
)
2×4 ● ● ● ● ● ● ● ●3.5×7 ● ● ● ● ● ● ● ●4×10 ● ● ● ● ● ● ● ● ●4×20 ● ● ● ● ● ● ● ● ●4×30 ● ● ● ● ● ● ●5×10 ● ● ● ● ● ● ● ● ●5×20 ● ● ● ● ● ● ● ● ●5×30 ● ● ● ● ● ● ● ● ●6×10 ● ● ● ● ● ● ● ● ●6×20 ● ● ● ● ● ● ● ● ●6×30 ● ● ● ● ● ● ● ● ●8×20 ● ● ● ● ● ● ● ● ●8×30 ● ● ● ● ● ● ● ● ●
● :Available
● :Available
● :Available
Vacuum Pad SeriesVacuum Pad
489
Vacuum Pad
■ Construction (VPA holder : Fixed type / Top port)
Nut (aNickel-plated brass or Trivalent chromate carbon steel ※ 3)
Pad holder (aNickel-plated brass)
Plain washer (Nickel-plated SPCC)
(bSpecial stainless steel ( Austenite or ferritic stainless steel) ※ 2)
(b Special stainless steel ( Austenite or ferritic stainless steel) ※ 2)
Vacuum pad
Pad screw (aNickel-plated brass)(bSpecial stainless steel ( Austenite or ferritic stainless steel) ※ 2)
Fitting (aNickel-plated brass)(b Special stainless steel ( Austenite or ferritic stainless steel) ※ 2)
Gasket (aSPCC+ NBR)(bSUS316+ FKM)
■ Construction (VPC holder : Spring type / Top port)
Stro
ke Nut (aNickel-plated brass or Trivalent chromate carbon steel ※ 3)(b Special stainless steel ( Austenite or ferritic stainless steel) ※ 2)
Bush (Nickel plated aluminum)
Plain washer (Nickel-plated SPCC)Vacuum pad
Pad screw (aNickel-plated brass)(b Special stainless steel ( Austenite or ferritic stainless steel) ※ 2)
Fitting (aNickel-plated brass)(b Special stainless steel ( Austenite or ferritic stainless steel) ※ 2)
Gasket (aSPCC+ NBR)(bSUS316+ FKM)
Shaft (aNickel-plated brass)(b Special stainless steel ( Austenite or ferritic stainless steel) ※ 2)
Rotation stopper (aNickel-plated brass)(bSpecial stainless steel ( Austenite or ferritic stainless steel) ※ 2)
Spring (SUS304)
※3. Nut material differs depending on the bulkhead thread size. See below table for details.Bulkhead thread size
(mm)Nut material
Nickel-plated brass Trivalent chromate carbon steelM5×0.5 ○ ーM6×0.75 ○ ーM8×0.75 ○ ーM10×1 ○ ーM12×1 ー ○M14×1 ー ○M16×1 ー ○M20×1 ー ○M22×1 ー ○M24×2 ○ ーM30×2 ○ ー
※1. a: Standard spec. b : “-S3” spec.※2. SUS303 equivalent corrosivity
43
Safety Instructions
Warning
This safety instructions aims to prevent personal injury and damage to properties by requiring proper use of PISCO products.
Be certain to follow ISO 4414 and JIS B 8370.ISO 4414:Pneumatic fluid power…General rules and safety requirements for system and their
components.JIS B 8370:General rules and safety requirements for systems and their components.
This safety instructions is classified into “Danger”, “Warning” and “Caution” depending on the degree of danger or damages caused by improper use of PISCO products.
Safety Instructions
Danger Hazardous conditions. It can cause death or serious personal injury.
Warning Hazardous conditions depending on usages. Improper use of PISCO products can cause death or serious personal injury.
Caution Hazardous conditions depending on usages. Improper use of PISCO products can cause personal injury or damages to properties.
※This safety instructions are subject to change without notice.
1.Selection of pneumatic products① .A user who is a pneumatic system designer or has sufficient experience and
technical expertise should select pneumatic equipments.② .Due to wide variety of operating conditions and applications for PISCO products,
carry out the analysis and evaluation on PISCO products. The pneumatic system designer is solely responsible for assuring that the user's requirements are met and that the application presents no health or safety hazards. All designers are required to fully understand the specifications of PISCO products and constitute all systems based on the latest catalog or information, considering any malfunctions.
2.Usage environmentDo not use PISCO products under the following conditions.① .Beyond the specifications or conditions stated in the catalog, or the instructions.② .Use at outdoors③ .Excessive vibrations and impacts.④ .Exposure / adhere to corrosive gas, flammable gas, chemicals, seawater, water and
vapor.
Danger1.Do not use PISCO products for the following applications.① .Equipment used for maintaining / handling human life and body.
② .Equipment used for moving / transporting human.
③ .Equipment specifically used for safety purposes.
https://en.pisco.co.jp/
44
3.Handling of product① .Handle the pneumatic equipment with enough knowledge and experience.
Mishandling of compressed air is dangerous. A person having enough knowledge and experiences should carry out assembly, operation, and maintenance of devices equipped with pneumatic equipments.
② .Do not operate machine / equipment or remove pneumatic equipment until safety is confirmed.⑴ .Make sure that preventive measures against falling work-pieces or sudden
movements of machine are completed before inspection or maintenance of these machine.
⑵ .Make sure the above preventive measures are completed. A compressed air supply and the power supply to the machine must be off, and also the compressed air in the systems must be exhausted.
⑶ .Restart the machines with care after ensuring to take all preventive measures against sudden movements.
③ .Do not disassemble or modify PISCO products, which affect the performance, function, and basic structure of the product.
④ .Take safety measures such as providing a protection cover if there is a risk of causing damages or fire on machine / facilities by a fluid leakage.
⑤ .Do not touch the release-ring of a push-in fitting when there is a working pressure. The lock may be released by the physical contact, and tube may fly out or slip out.
⑥ .Frequent switchover of compressed air may generate heat, and there is a risk of causing burn injury.
⑦ .Avoid any load on PISCO products, such as, a tensile strength, twisting and bending. Otherwise, there is a risk of causing damage to the products.
⑧ .Do not use PISCO products for applications where threads or tubes swing / rotate. The product can be damaged in these applications.
⑨ .Do not swing or rotate resin body of the products by force. It may damage to the products and cause a fluid leakage.
⑩ .Do not supply excessively dry air to products. It may cause malfunction due to a deterioration of rubber parts.
⑪ .Do not wash or paint products with water or solvent. Solvent may damage a resin body, or painting may cause malfunction.
⑫ .The product incorporating NBR as seal rubber or gasket material has a risk of malfunction caused by ozone crack. Ozone exists in high concentrations in static elimination air, clean-room, and near the high-voltage motors, etc. As a countermeasure, material change from NBR to HNBR or FKM is necessary. Consult with Pisco for more information.
⑬ .Do not stand on a product, or put anything on it. It may cause falls, personal injury or damage to the product.
45
真空発生器・真空ポンプ対応ユニット・真空パッド・真空関連機器SeriesIndexSafety Instructions
Safety Instructions
Warranty
Disclaimer
When the product produces a trouble, which is caused by our responsibility, we will carry out either one of the following measures immediately.① .Free-of-charge replacement of same product② .Free-of-charge repair of the product at our factory
1.PISCO does not take any responsibility for any incidental or indirect loss, such as production line stop, interruption of business, loss of benefits, personal injury, etc., caused by any failure on use or application of PISCO products.
2.When a cause of the trouble/malfunction applies to any of the following items, it is excluded from the coverage of the above warranty.① .A case by a natural disaster, a fire except our responsibility, the act by the third
person/party, the intention or fault of the customer.② .A case when a product is used out of the specific range or in a method listed in the
product catalog or the instruction manual.③ .A case by the remodeling of the product or by a change of structure, performance, or
specifications which PISCO does not involved in.④ . A case by the event that is unpredictable by the evaluations and the measures at the
time on or before the initial delivery.⑤ .A case caused by the phenomenon that is able to be evaded if your machine or
equipment has functions or structures that are comprised in a common sense when this product is incorporated in your machine or equipment.
3.The damages caused by the defect of Pisco products shall be covered but l imi ted to the fu l l amount of the PISCO products paid by the customer. Additionally, the above warranty is limited simply to the product itself. The damage induced by the trouble of the product will not be compensated.
https://en.pisco.co.jp/
46
Caution1.An odd noise may be heard when supply pressures are immediately before the peak of vacuum levels.
The sounding of this odd noise means the characteristics are unstable and the sound may become even noisier. This situation can also adversely affect the sensor, resulting in a malfunction or trouble. So reset the supply pressure.※Pressure range in which odd noise occurs is affected by atmospheric pressure.
2.Piping design and equipment selection should be made with an effective sectional area on supply pressure side of a vacuum generator being 3 times as large as the nozzle diameter as a standard. Insufficient air flow may impair the performance of the product.
3.Do not use a lubricator on products.4.Clean or replace silencer element periodically. There is a possibility of dropping the performance or
causing troubles by clogging on the element.5.Keep products away from water, oil drops or dusts because they are neither drip-proof nor dust-proof.
Otherwise there is a possibility of causing malfunction, damage to the products, or dropping the performance.
6.Piping① .Compressed air contains a volume of drain (water, oxidized oil, tar and foreign material, etc.)
Because the drain reduce product performance remarkably, dehumidify air with an aftercooler and a dryer, and improve the air quality.
② .Do not use a lubricator on products.③ .Rust in pipe and inflow of foreign substances cause the trouble, malfunction, and degradation of the
product. Please install a filter (5μm or better filtration) in the compressed air supply line right in front of the product. The flushing inside the pipe before use and in certain intervals is recommended.
④ .Remove dusts or drain before piping. They may get into the peripheral machine / facilities and cause malfunction.
⑤ .When inserting an ultra-soft tube into push-in fitting, make sure to place an Insert Ring into the tube edge. There is a risk of causing the escape of tube and a fluid leakage without using an Insert Ring.
⑥ .Arrange piping avoiding any load on fittings and tubes such as twist, tensile, moment load, shaking and physical impact. These may cause damages to fittings, tube deformations, bursting and the escape of tubes.
⑦ .Install protective cover when using at a place getting the direct sunlight.⑧ .Be sure to confirm each port of a vacuum generator with its appearance drawing or the marking on
it before piping. Incorrect piping has a risk of damaging the product.⑨ .Plumb a pressure sensor and a vacuum generator with pressure sensor at the end of vacuum
system as much as possible. A long distance between a pressure sensor and a vacuum system end may increase plumbing resistance which may lead to a high vacuum level at the sensor even when no suctioning and a malfunction of pressure sensor. Make sure to evaluate the products in an actual system.
⑩ .A Shorter distance of plumbing with a wider bore is preferable at vacuum system side. A long plumbing with a small bore may result in slow response time at the time of releasing work-piece as well as in failure to secure adequate suction flow rate.
Common Safety Instructions for Products in This catalog
Common Safety Instructions for Products Listed in This Manual
47
IndexCommon Safety Instructions for Products Listed in This Manual
⑪ .In case of using non-PISCO brand tubes, make sure the tolerance of the outer tube diameter is within the limits of Table 1.●Table 1. Tube O.D. Tolerance
mm size Nylon tube Polyurethane tube inch size Nylon tube Polyurethane tube
ø1.8mm ─ ±0.05mm ø1/8 ±0.1mm ±0.15mmø2mm ─ ±0.05mm ø5/32 ±0.1mm ±0.15mmø3mm ─ ±0.15mm ø3/16 ±0.1mm ±0.15mmø4mm ±0.1mm ±0.15mm ø1/4 ±0.1mm ±0.15mmø6mm ±0.1mm ±0.15mm ø5/16 ±0.1mm ±0.15mmø8mm ±0.1mm ±0.15mm ø3/8 ±0.1mm ±0.15mm
ø10mm ±0.1mm ±0.15mm ø1/2 ±0.1mm ±0.15mmø12mm ±0.1mm ±0.15mm ø5/8 ±0.1mm ±0.15mmø16mm ±0.1mm ±0.15mm
7-1.Tube insertion (Push-in fitting)① .Make sure that the cut end surface of the tube is at a right angle without a scratch
on the tube surface or deformations.② .When inserting a tube, the tube needs to be inserted fully into the push-in fitting
until the tubing edge touches the tube end of the fitting as shown in the figure below. Otherwise, there is a risk of leakage.
Tube end
Sealing
Tube is not fully inserted up to tube end.
7-2.Tube insertion (Compression fitting)① .Make sure that the cut end surface of the tube is at a right angle without
deformations or a scratch on its inner and outer surface.② .Pass the tube through the nut and insert the barb into the tube up to the barb end.
Then tighten the hexagonal-column of the nut with a proper tool.③ .Refer to Table 2 which shows the tightening torque.※※Hold the tube when tightening the nut, since the tube may rotate along with the Hold the tube when tightening the nut, since the tube may rotate along with the
nut.nut.
③ . After inserting the tube, make sure it is inserted properly and not to be disconnected by pulling it moderately.※When inserting tubes, Lock-claws may be hardly visible in the hole, observed
from the front face of the release-ring. But it does not mean the tube will surely escape. Major causes of the tube escape are the followings; ① Shear drop of the lock-claws edge ② The problem of tube diameter (usually small)Therefore, follow the above instructions from ① to ③ , even lock-claws is hardly visible.
https://en.pisco.co.jp/
489.Installation of a fitting① .When installing a fitting, use proper tools to tighten a hexagonal-column or an inner
hexagonal socket. When inserting a hex key into the inner hexagonal socket of the fitting, be careful so that the tool does not touch lock-claws. The deformation of lock-claws may result in a poor performance of systems or an escape of the tube.
② .Refer to Table 3 in the next page which shows the tightening torque, when tightening a thread. Do not exceed these limits to tighten a thread. Excessive tightening may break the thread part or deform the gasket to cause a fluid leakage. Tightening thread with tightening torque lower than these limits may cause a loosened thread or a fluid leakage. Since the sealability is affected by the processing condition of the installing part, adjust the tightening torque or correct the installing part, according to the condition.
③ .Adjust the tube direction while tightening thread within these limits, since some PISCO products are not rotatable after the installation.
④ .Make sure that the nut touches the metallic body. If not, loosen the nut, disconnect the tube and start over again from the process ①
⑤ .Make sure that there is no leakage after tightening the nut.⑥ .After inserting the tube, make sure it is inserted properly and not to be
disconnected by pulling it moderately.●Table 2. Nut tightening torque
Tube O.D. Tightening torque
ø10 Max. 4N·mø12 Max. 5N·mø16 Max. 14N·m
8-1.Tube disconnection (Push-in fitting)① .Make sure there is no air pressure inside of the tube, before disconnecting it.② .Push the release-ring of the push-in fitting evenly and deep enough to pull out the
tube toward oneself. By insufficient pushing of the release-ring, the tube may not be pulled out or damaged by scratch, and tube shavings may remain inside of the fitting, which may cause the leakage later.
8-2.Tube disconnection (Compression fitting)① .Make sure there is no air pressure inside of the tube, before disconnecting it.② .Use a proper tool to loosen the nut. Then disconnect the tube.
49
IndexCommon Safety Instructions for Products Listed in This Manual
●Table 3. Tightening torque / Sealock color / Gasket materialsThread type Thread size Tightening torque Sealock color Gasket material
Metric thread
M3×0.5 0.7N·m
n/a
SUS304+NBRSPCC+NBRM5×0.8 1 ~ 1.5N·m
M6×1 2 ~ 2.7N·mM3×0.5 0.7N·m
POMM5×0.8 1 ~ 1.5N·mM6×0.75 0.8 ~ 1N·mM8×0.75 1 ~ 2N·m
Taper pipe thread
R1/8 4.5 ~ 6.5N·m
White ─R1/4 7 ~ 9N·mR3/8 12.5 ~ 14.5N·mR1/2 20 ~ 22N·m
Unified thread No.10-32UNF 1 ~ 1.5N·m n/a SUS304+NBR, SPCC+NBR
National PipeThread Taper
(Americanstandard)
1/16-27NPT 4.5 ~ 6.5N·m
White ─1/8-27NPT 4.5 ~ 6.5N·m1/4-18NPT 7 ~ 9N·m3/8-18NPT 12.5 ~ 14.5N·m1/2-14NPT 20 ~ 22N·m
G threadG1/4 12 ~ 14N·m
n/a Aluminum + PBTG3/8 22 ~ 24N·mG1/2 28 ~ 30N·m
※These values may differ for some products. Refer to each specification as well.
④ .When removing a fitting, use proper tools to loosen a hexagonal-column. When inserting a hex key into the inner hexagonal socket of the fitting, be careful so that the tool does not touch lock-claws. The deformation of lock-claws may result in a poor performance of systems or an escape of the tube.
⑤ .Remove the sealant stuck on the mating equipment. The remained sealant may get into the peripheral equipment and cause malfunctions.
10.Handling of PISCO products① .Impact caused by dropping or the like may lead to damage to the product and a fluid
leakage.11.PISCO products shall be used within the Operating temp. range, including the heat of
the product itself generated by adiabatic compression.