Page 1: V11 Series - Burnham Commercial BoilersV11 boiler sections have reinforced lugs that are used to assemble the sections with individual draw rods resulting in fast, strain-free assembly.

Cast Iron Commercial Water or Steam Boiler

837 to 5733 MBH Input

Oil, Gas, or Oil/Gas Combination

30, 50, or 80 PSI

Cast Iron Sectional Design

Water or Steam

Top or Rear Venting

Exclusive Optional SBC Boiler Controlª

Ð M aximizes System Efficiency

V11 Series

1

Page 2: V11 Series - Burnham Commercial BoilersV11 boiler sections have reinforced lugs that are used to assemble the sections with individual draw rods resulting in fast, strain-free assembly.

Installation & Service FlexibilityThecastironsectionaldesignoftheV11boilermakesiteasytomaneuver through doorways and into the boiler room. In addi-tion to being shipped as loose sections, the boiler is available with factory-assembled sections or as a completely packaged and fire-tested unit.

• Hassle-free Section Assembly V11boilersectionshavereinforcedlugsthatareused to assemble the sections with individual draw rods resulting in fast, strain-free assembly.

The sections can be assembled using two common toolsÑ a 3/4" drive ratchet with a 1-1/16" deep socket and wrench. The sections are surface ground to ensure smooth surface mating. An elastic sealant and fiberglass rope are used on all section joints for a completely sealed and pressure-tight assembly.

• extensive Testing Methods Each boiler section is hydrostatically tested at 2-1/2 times theratedworkingpressureatthefoundry.Factory- assembled sections are tested a second time at 1.5 times the rated working pressure.

• Rear or Top Venting Asaforceddraftboiler,theV11 provides optimum draft for controlled efficiency, eliminating the need for high chimneys or induced draft fans. AuniquefeatureoftheV11boiler is that it can be vented from the rear or the top. This enables easy chimney or sidewall venting for maximum installation flexibility. Top outlet venting saves floor space and reduces installation time and materials. A plugged tapping is provided to take flue outlet pressure readings.

Available in twenty sizes with gross output ratings from 667to4551MBH,theV11Seriesiscommonlyusedinschools, hospitals, and other large commercial applications where comfort and reliability are critical. The product meets theenergyefficiencyrequirementsofASHRAE90.1withcombustion efficiencies up to 85%.

Cast iron construction, ease of assembly, two venting options, andstringenttestingmethodsmaketheV11SeriesboilerbyBurnham Commercial your commercial heating solution.

American-Made Cast Iron ConstructionÐBC25-HSiBurnham CommercialÕ s unique BC25-HSicastironformulahasan extremely high silicon content, making it stronger and more flexible than the iron used in competitor's boiler sections. It offers better thermal shock resistance and greater heat transfer capabilities than other cast iron products. BC25-HSi'spropertiesallowBurnhamCommercialtomaintain the highest level of quality from start to finish, and provide a product that is optimized for hydronic heating applications.

• Manufactured with Quality Cast iron sections are produced at BurnhamFoundryLLCinOhio, ensuring quality and availability of boiler sections.

• Cast Iron nipple Difference V11sectionsareheldtogether using cast iron nipples, which are well known as being of the highest standard for boiler construction. Unlike gaskets used by many other boiler manufacturers, cast iron nipples are impervious to flue gases, oils, petroleum-based chemicals and other contaminants, which means fewer costly repairs and a longer lasting boiler.

Cast Iron Commercial Water or Steam BoilerCast Iron Commercial Water or Steam BoilerV11 Series

Your Commercial Heating Solution!

2

Page 3: V11 Series - Burnham Commercial BoilersV11 boiler sections have reinforced lugs that are used to assemble the sections with individual draw rods resulting in fast, strain-free assembly.

Front Mounted Controlsfor easy adjustment and maintenance

Top or Rear Outletwith adjustable lock-type damper (not shown); includes plugged tapping for outlet pressure readings

Cast Iron Sections

Verticalfluedesignwith pinned heating surface for maximum heat extraction

Removable Side Jacket panelsEasy access to all cleanouts and flue surfaces

Burner Mounting platewith flame observation port

4 Burner ManufacturersOptionstobest fit your needs

Individual Draw Rodswith reinforced lugs for strain free assembly

Optional Tankless Heater Providesdomestichotwater

Aluminized Steel Canopy

Cast Iron nipplesensure the integrity of the section assembly and resistpetroleum based chemicals and flue gases

Rear Observation portIncludes plugged tapping for over-fire draft readings

Wet BaseSide wall insulation creates improved thermal circulation

Commitment to QualityBurnham Commercial, "America's Boiler Company," has earned a reputation for quality and dependability. Built for a variety of applications,theV11Seriesisrightforyournextjob.

The SBC Boiler Control SystemÉOnly available from Burnham Commercial!

thermal circulationthermal circulation

SBCTM

Integrated Boiler Control System

Burnham CommercialÕ s SBC is a complete boiler monitoring and automation system. Available as an option, this exclusive feature wasdesignedanddevelopedbyBurnhamCommercial’sengineersandisavailableONLYon Burnham Commercial products.

Designedtomaximizesystemefficiency and minimize energy usage

Easily connected to building management systems

Provencontrolplatform,usedsuccessfully for years at other Burnham companies

Fail-safedesigninsuresboileroperation

Also AvailableÉ

SBC Exclusives•AdvancedAdaptability•Peer-To-PeerNetwork •Fail-Safe System Operations•BoilerMonitoring&DiagnosticDisplays•ModulationRateandOn/OffModes•Outdoor Air Temperature Reset•Warm Weather Shutdown (WWSD)•Domestic Hot Water Priority (DHWP)

•System Control Outputs

3

Page 4: V11 Series - Burnham Commercial BoilersV11 boiler sections have reinforced lugs that are used to assemble the sections with individual draw rods resulting in fast, strain-free assembly.

all dimensions in inches

* Burnercontrolpanelconfigurationmaychangethisdimension

BOILeR MODeL

nUMBeROF

SeCTIOnS 'A' 'B' 'C' 'D' 'e' 'F' 'G' 'H' 'J' 'K' 'L'

BURneR DIMenSIOn - 'M' *AppROX.

WeIGHT OF SeCTIOn

(Assembly Only)

BeCKeTT

CARLIn

pOWeRFLAMe WeBSTeR

CF CG CR JR** JBV1104V1105V1106V1107V1108V1109V1110

45678910

26-5/832-3/438-7/8

4551-1/857-1/463-3/8

18-7/825

31-1/837-1/443-3/849-1/255-5/8

ÑÑ

31-1/837-1/443-3/849-1/224-3/4

ÑÑÑÑÑÑ

30-7/8

ÑÑÑÑÑÑÑ

ÑÑÑÑÑÑÑ

ÑÑÑÑÑÑÑ

13-13/1619-15/1626-1/1632-3/1638-5/1644-7/1650-9/16

55555554545453

88810101012

1223344

24-3/424-3/424-3/424-1/424-1/424-1/424-1/4

21-3/421-3/428-3/429-1/429-1/429-1/429-1/4

Ñ19-3/419-3/420-1/220-1/220-1/225-5/8

30303535353535

20-1/420-1/423-3/423-3/423-3/4

ÑÑ

25252525252525

1833222626183010340337954188

V1111V1112V1113V1114V1115V1116V1117

11121314151617

69-1/275-5/881-3/487-7/8

94100-1/8106-1/4

61-3/467-7/8

7480-1/886-1/492-3/898-1/2

373737

24-3/424-3/430-7/830-7/8

24-3/430-7/8

3724-1/224-1/236-3/436-3/4

ÑÑÑ

30-7/837

24-3/430-7/8

ÑÑÑÑÑÑÑ

ÑÑÑÑÑÑÑ

56-11/1656-5/8

53-5/1653-5/1653-5/1653-5/1653-5/16

53535352525252

12121214141414

4555666

24-1/425-3/425-3/4

272726Ñ

29-5/829-5/829-5/829-5/829-5/829-5/829-5/8

25-5/825-5/826-1/826-1/826-1/826-1/826-1/8

40404040404040

ÑÑÑÑÑÑÑ

29292929292929

4580497253655757615065426934

V1118V1119V1120V1121V1122V1123

181920212223

112-3/8118-1/2124-5/8130-3/4136-7/8

143

104-5/8110-3/4116-7/8

123129-1/8135-1/4

30-7/830-7/830-7/830-7/830-7/830-7/8

24-1/224-1/224-1/224-1/224-1/224-1/2

24-1/224-1/236-3/436-3/424-1/224-1/2

24-3/430-7/824-3/430-7/824-1/224-1/2

ÑÑÑÑ

24-3/430-7/8

53-5/1653-5/1653-5/1653-5/1653-5/1653-5/16

515151515050

161616161818

778899

ÑÑÑÑÑÑ

29-5/829-5/8

ÑÑÑÑ

ÑÑÑÑÑÑ

404040404646

ÑÑÑÑÑÑ

292929292929

732777198112850488969289

V11 Series Dimensions

FRONT OBSERVATION

PORT

4

Page 5: V11 Series - Burnham Commercial BoilersV11 boiler sections have reinforced lugs that are used to assemble the sections with individual draw rods resulting in fast, strain-free assembly.

nOTeS:1.Allpipingisschedule40.2. Pipesizelistedarebasedona20°For40°F differential (temperature drop). Select one to match application.3.Whenspecifiedreturnpipingsizeislessthan3", install 3" x 12" nipple and appropriate size bell reducer directly into boiler return tapping as shown.4.Drainvalve-ballvalvepreferable,gatevalveacceptable alternative (supplied by others). MinimumvalvesizeperASMEcodeis3/4"NPT.5. Swing joints on two riser systems may be piped over the top of the boiler if space is limited.6. Boilers require protection from flue gas condensation and thermal shockwhenoperatingbelow135°Freturnwatertemperatures

pipe Sizing and notes

BOILeRMODeL

SUppLy pIpInG SIZe In InCHeS ReTURn pIpInG SIZe In InCHeS

(1)SUppLy

(1A)SUppLy HeADeR

(1B) SUppLy RISeR

(QTy.) SIZe(2)

ReTURn

(2A)ReTURn HeADeR

(2B) ReTURn BRAnCH

(QTy.) SIZe20¡ FDROp

40¡ FDROp

20¡ FDROp

40¡ FDROp

20¡ FDROp

40¡ FDROp

20¡ FDROp

40¡ FDROp

20¡ FDROp

40¡ FDROp

20¡ FDROp

40¡ FDROp

V1104V1105V1106V1107V1108V1109V1110

2-1/22-1/22-1/2

3344

22222

2-1/22-1/2

ÑÑÑÑÑÑÑ

ÑÑÑÑÑÑÑ

ÑÑÑÑÑÑÑ

ÑÑÑÑÑÑÑ

2-1/22-1/22-1/2

3344

22222

2-1/22-1/2

ÑÑÑÑÑ33

ÑÑÑÑÑÑÑ

ÑÑÑÑÑ

(2) 3(2) 3

ÑÑÑÑÑÑÑ

V1111V1112V1113V1114V1115V1116V1117

4444455

2-1/2333333

ÑÑÑÑÑ33

ÑÑÑÑÑÑÑ

ÑÑÑÑÑ

(2) 3(2) 3

ÑÑÑÑÑÑÑ

4444455

2-1/2333333

3333333

ÑÑÑÑÑÑÑ

(2) 3(2) 3(2) 3(2) 3(2) 3(2) 3(2) 3

ÑÑÑÑÑÑÑ

V1118V1119V1120V1121V1122V1123

555555

444444

444444

ÑÑÑÑÑÑ

(2) 4(2) 4(2) 4(2) 4(2) 4(2) 4

ÑÑÑÑÑÑ

555555

444444

444555

333333

(3) 3(3) 3(3) 3(3) 3(3) 3(3) 3

(2) 3(2) 3(2) 3(2) 3(2) 3(2) 3

V11 Series Piping RecommendationsWater Boiler

5

Page 6: V11 Series - Burnham Commercial BoilersV11 boiler sections have reinforced lugs that are used to assemble the sections with individual draw rods resulting in fast, strain-free assembly.

nOTeS:1. Allpipingisschedule40.2. To prevent condensate from being trapped in header, do not reduce equalizer elbow at header connection.3. Drain/blowoffvalve—ballvalvepreferable,gatevalveacceptable alternative (supplied by others). -MinimumvalvesizeperASMEcodeis1"NPT(V1104-1106),1-1/4" NPT(V1107-1112),1-1/2"NPT(V1113-1123). - Increasing the valve size will improve the blowdown operation - In all cases, piping connecting blowoff valve to boiler shall be full size to the point of discharge.4. Headerpipingmayberunoverthetopofboilerifspacedoesnot allow for piping arrangement shown. However,increasedservicerequirementswillresult.5. Supply from boiler header must be connected between the first boiler riserandtheheaderdrip(orhartfordloop).Donotconnectsupply between risers or opposite end of boiler header.6. Forpumpedreturnsystems,seeV11installationmanual.

'A'

'A'

'B''C'

'A'

'B'

'C'

'A'

'B'

'C'

'D'

18"MIN.

24"MIN.

HEADER3

'E''D'

V1104 AND V1105

V1114 THRU V1117 V1118 THRU V1121 V1122 AND V1123

V1106 THRU V1109

'A''B'

V1 110 THRU V1113

EQUALIZER

CLOSE NIPPLE

HARTFORD LOOP(REQ'D ON GRAVITYRETURN SYSTEM)

4

RETURN2

BLOWOFF/DRAIN VALVE(SEE NOTE 3)

REAR OF BOILER

2" TO 4"WATER LINE

SUPPLY(SEE NOTE 5)

5

RISER1

BOILeRMODeL

pIpInG SIZe In InCHeS RISeR SpACInG In InCHeS(1)

RISeR (QTy.) SIZe

(2) ReTURn

(3)HeADeR

(4)eQUALIZeR ÔAÕ ÔBÕ ÔCÕ ÔD Õ Ô eÕ

V1104V1105V1106V1107V1108V1109V1110

(1) 4(1) 4(2) 4(2) 4(2) 4(2) 4(3) 4

22

2-1/22-1/22-1/22-1/22-1/2

4466666

2-1/22-1/22-1/22-1/22-1/22-1/22-1/2

ÑÑ

31-1/837-1/443-3/849-1/224-3/4

ÑÑÑÑÑÑ

30-7/8

ÑÑÑÑÑÑÑ

ÑÑÑÑÑÑÑ

ÑÑÑÑÑÑÑ

V1111V1112V1113V1114V1115V1116V1117

(3) 4(3) 4(3) 4(4) 4(4) 4(4) 4(4) 4

3333333

8888888

4444444

373737

24-3/424-3/430-7/830-7/8

24-3/430-7/8

3724-1/224-1/236-3/436-3/4

ÑÑÑ

30-7/837

24-3/430-7/8

ÑÑÑÑÑÑÑ

ÑÑÑÑÑÑÑ

V1118V1119V1120V1121V1122V1123

(5) 4(5) 4(5) 4(5) 4(6) 4(6) 4

333333

81010101010

444444

30-7/830-7/830-7/830-7/830-7/830-7/8

24-1/224-1/224-1/224-1/224-1/224-1/2

24-1/224-1/236-3/436-3/424-1/224-1/2

24-3/430-7/824-3/430-7/824-1/224-1/2

ÑÑÑÑ

24-3/430-7/8

V11 Series Piping RecommendationsSteam Boiler

6

Page 7: V11 Series - Burnham Commercial BoilersV11 boiler sections have reinforced lugs that are used to assemble the sections with individual draw rods resulting in fast, strain-free assembly.

STANDARD BURNER MOTOR VOLTAGE: Beckett–CF1400,andCF2300are120/60/1.CF2500andCF3500are240/60/3.Carlin–Allsizes240/60/1.power Flame–CR1-OSis120/60/1.CR2-OASis240/60/1.Allothersare240/60/3.Webster–JB10-03,JB10-05andJB10-07are120/60/1.JB20-10is240/60/1.Allothersare240/60/3.

GAS BURneRS*

STANDARD BURNER MOTOR VOLTAGE: power Flame C Series–CR1-G-12andCR2-G-15are120/60/1.CR2-G-20Ais240/60/1.Allothersare240/60/3.power Flame JR Series –Allburnersare120/60/1.Webster–JB1G-03,JB1G-05andJB1G-07are120/60/1.JB2G-10is240/60/1.Allothersare240/60/3.*Forinletgasconnectionsize,seeGas/OilBurnerChart=Forminimumgaspressurerequirements,seeGas/OilBurnerChart.

GAS/OIL BURneRS

STANDARD BURNER MOTOR VOLTAGE: power Flame-CR1-GO-12is120/60/1.CR-2-GO-15andCR2-GO-20Aare240/60/1.Allothersare240/60/3.Webster–JB1C-03,JB1C-05,JB1C-07are120/60/1.JB2C-10is240/60/1.Allothersare240/60/3.**Forminimumgaspressurerequirements,seeGasBurnerChart.NOTES:1.TheminimumgaspressuresshownareforstandardULburnerswiththestandardfiringsequence.IRI,FMandCSD-1requirementsmayresultindifferentpressuresandprices.

BOILeRnUMBeR

BeCKeTT CARLIn pOWeR FLAMe WeBSTeRBURneR MODeL H.p. BURneR MODeL H.p. BURneR MODeL H.p. BURneR MODeL H.p.

V1104V1105V1106V1107V1108V1109V1110V1111V1112V1113V1114V1115V1116V1117V1118V1119V1120V1121V1122V1123

CF1400CF1400CF1400CF2300CF2300CF2300CF2300CF2300CF2500CF2500CF3500CF3500CF3500

ÑÑÑÑÑÑÑ

1/21/21/23/43/43/43/43/422222

ÑÑÑÑÑÑÑ

Ñ702CRD702CRD801CRD801CRD801CRD1050FFD1050FFD1050FFD1050FFD1150FFD1150FFD1150FFD1150FFD

ÑÑÑÑÑÑ

Ñ1/21/23/43/43/411

1-1/21-1/21-1/21-1/21-1/21-1/2

ÑÑÑÑÑÑ

CR1-OSCR1-OSCR2-OASCR2-OASCR2-OASCR2-OASCR2-OASCR3-OCR3-OCR3-OCR3-OCR3-OCR3-OCR3-OCR3-OBCR3-OBCR3-OBCR3-OBCR4-OACR4-OA

1/21/23/43/43/43/4

1-1/22222233333355

JB1O-03JB1O-03JB1O-03JB1O-05JB1O-05JB1O-07JB1O-07JB2O-10JB2O-10JB2O-10JB2O-10JB2O-10JB2O-15JB2O-30JB2O-30JB2O-30JB2O-30JB2O-50JB2O-50JB2O-50

1/31/31/31/21/23/43/411111

1-1/23333555

BOILeRnUMBeR

BeCKeTT pOWeR FLAMe - 'CR'= pOWeR FLAMe - 'JR'= WeBSTeRBURneRMODeL H.p.

MIn. GASpReSS. (In.)

BURneRMODeL H.p.

BURneRMODeL H.p.

BURneRMODeL H.p.

MIn. GASpReSS. (In.)

V1104V1105V1106V1107V1108V1109V1110V1111V1112V1113V1114V1115V1116V1117V1118V1119V1120V1121V1122V1123

CG10.6SCG10.6SCG15.4SCG25.2SCG25.3SCG25.4SCG25.5SCG50.2SCG50.3SCG50.3SCG50.4SCG50.5SCG50.5SCG50.5SCG50.5SCG50.5S

ÑÑÑÑ

1/31/31/23/43/43/43/4222222222

ÑÑÑÑ

4.66.66.25.25.05.25.25.74.35.75.75.05.36.16.97.3ÑÑÑÑ

CR1-G-12CR1-G-12CR2-G-15CR2-G-15CR2-G-15CR2-G-15CR2-G-20ACR3-G-20CR3-G-20CR3-G-20CR3-G-20CR3-G-20CR3-G-25CR3-G-25CR3-G-25BCR3-G-25BCR3-G-25BCR3-G-25BCR4-G-25CR4-G-25

1/31/21/21/21/21/21

1-1/21-1/21-1/21-1/21-1/2

33333333

JR30A-10JR30A-12JR50A-15JR50A-15JR50A-15

ÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑ

1/31/31/31/21/2ÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑ

JB1G-03JB1G-03JB1G-03JB1G-05JB1G-05JB1G-07JB1G-07JB2G-10JB2G-10JB2G-10JB2G-15JB2G-30JB2G-30JB2G-30JB2G-30JB2G-30JB2G-30JB2G-50JB2G-50JB2G-50

1/31/31/31/21/23/43/4111

1-1/2333333555

64655888678889101112141516

BOILeRnUMBeR

pOWeR FLAMe - 'CR' SeRIeS WeBSTeRBURneRMODeL H.p.

InLeT GASCOnneCTIOn (In.)

MIn. GASpReSS. (In.)

BURneRMODeL H.p.

InLeT GASCOnneCTIOn (In.)

MIn. GASpReSS. (In.)

V1104V1105V1106V1107V1108V1109V1110V1111V1112V1113V1114V1115V1116V1117V1118V1119V1120V1121V1122V1123

CR1-GO-12CR1-GO-12CR2-GO-15CR2-GO-15CR2-GO-15CR2-GO-15CR2-GO-20ACR3-GO-20CR3-GO-20CR3-GO-20CR3-GO-20CR3-GO-20CR3-GO-25CR3-GO-25CR3-GO-25BCR3-GO-25BCR3-GO-25BCR3-GO-25BCR4-GO-25CR4-GO-25

1/21/23/43/43/43/4

1-1/22222233333355

11111

1-1/41-1/4

21-1/21-1/21-1/21-1/2

222

2-1/22-1/22-1/22-1/22-1/2

4.74.85.46.47.56.45.85.86.06.87.47.36.67.17.76.57.07.06.36.9

JB1C-03JB1C-03JB1C-03JB1C-05JB1C-05JB1C-07JB1C-07JB2C-10JB2C-10JB2C-10JB2C-10JB2C-10JB2C-15JB2C-30JB2C-30JB2C-30JB2C-30JB2C-50JB2C-50JB2C-50

1/31/31/31/21/23/43/411111

1-1/23333555

11-1/41-1/41-1/41-1/21-1/21-1/2

2222222

2-1/22-1/22-1/22-1/22-1/22-1/2

7.04.97.06.26.97.07.06.35.66.37.06.87.07.38.19.210.011.012.413.1

OIL BURneRS

V11 Series Burner Schedule

7

Page 8: V11 Series - Burnham Commercial BoilersV11 boiler sections have reinforced lugs that are used to assemble the sections with individual draw rods resulting in fast, strain-free assembly.

Specifications

1. Suffix“S”indicatessteamboiler,“W”indicateswaterboiler.Suffix“G”indicatesgas-fired,“O”indicatesoilfiredand“GO”indicatescombination gas/oil fired.2. Boilerratingsarebasedon13%CO2onoil;10.0%CO2ongas,and+.10in.watercolumnpressureatboilerflueoutlet.3. I=B=Rnetratingsshownarebasedonpipingandpickupallowanceswhichvaryfrom1.333to1.288forsteamand1.15forwater.Consult manufacturer for installations having unusual piping and pick up requirements, such as intermittent system operation, extensive piping systems, etc.4. TheI=B=RburnercapacityinGPHisbasedonoilhavingaheatvalueof140,000BTUpergallon.Ratingsshownaboveapplytoaltitudesupto1000feetforoiland2000feetforgas.Foraltitudesabovethoseindicated,theratingsshouldbereducedattherateof4%foreach1000feetabovesealevel.nOTe: Maximumallowableworkingpressure(MAWP): Steam: 15PSI Water–USA: 80PSI(Standardreliefvalveprovidedis50PSI)(80PSI/30PSIOptional) Water–Canada: 50PSI(Standardreliefvalveprovidedis50PSI)(30PSIOptional)

STAnDARD eQUIpMenTALL BOILeRS:Sectionsunassembled,flushinsulatedjacket,burnermountingplate,rearobservationportcover,firewallplates,targetwall(V1104-1106only), rear flue outlet damper (top outlet optional), flue canopy, trim, and miscellaneous plugs, bushing and fittingsSTeAM TRIM:15PSIsafetyvalve,L404Fpressuretrol,gaugeglassassembly,steamgaugeWATeR TRIM:50PSIsafetyreliefvalve,L4006Ahighlimit,pressuretemperaturegaugeOIL BOILeRS:Flangemountedflameretentionoilburnerfurnishedwith2stagefuelunit,primarycontrolanddualoilvalvesGAS BOILeRS:FlangemountedgasburnerwithstandardcontrolsmeetingthelatestULrequirements,dualgasvalves,gas-electricignitionwithprovengaspilot,flamerodonJRburner,ultravioletflamedetectoronothers,electronicprogrammingcontrolsandcomponentsarefactorywiredinaburnermountedcontrolpanel(exceptJR-panelavailableasanoption)GAS/OIL BURneRS:Flangemountedcombinationgas/oilburnerwithstandardcontrolsmeetinglatestULrequirements,manuallyoperatedfueltransferswitch for dual fuel changeover, dual gas valves and oil valves, electric ignition with proven gas pilot on both fuels (direct spark ignition of oil is op-tional), ultra-violet flame detector, electronic programming controls and components are factory wired in a burner mounted control panel

OpTIOnAL eQUIpMenTAssembled sections; completely packaged (includes manual reset high limit and manual reset low water cutoff); packaged and fire-tested; top outlet flue damper;tanklessheaters;sideinspectiontappingswithbrassplugs;pressurereliefdoor;30PSIand80PSIsafetyreliefvalves;combustionandhydroniccontrolstomeetspecialapplicationsincludingF.M.,I.R.I.,andASMECSD-1.

V11 RATInGS

BOILeRMODeL

(1)BOILeR

H.p.

GROSSOUTpUT

MBH(2)

I=B=R neT RATInG (3) BURneR InpUT neTFIReBOXVOLUMe(In. WTR.COLUMn)

pReSSUReIn

FIReBOX(In. WTR.COLUMn)

I=B=RVenT DIA.

(In.)

AppROX.SHIppInG

AnD LIFTInGWeIGHT(LBS.)

STeAM

WATeRMBH

OILGpH(4)

GASMBHMBH SQ. FT.

V1104V1105V1106V1107V1108V1109V1110

19.925.631.938.345.351.758.0

66785710691281151717291941

500643802963115913351507

2083267933424013482955636279

5807459301114131915031688

5.87.49.211.013.014.816.6

837106813281588187621362396

7.910.613.215.918.521.123.8

.35

.36

.37

.42

.42

.39

.42

88810101012

2105251029203325373341474557

V1111V1112V1113V1114V1115V1116V1117

64.369.774.881.688.393.4100.2

2154233425032730295731293353

1672181219432120229624272603

696775508096883395671011310846

1873203021772374257127182916

18.420.021.523.525.527.029.0

2656288731033392368038974186

26.529.131.834.437.139.742.4

.40

.42

.40

.38

.36

.38

.41

12121214141414

4964537457716184660170087417

V1118V1119V1120V1121V1122V1123

106.9111.7118.2124.7129.5136.0

358037393957417443344551

278029033072324133653533

115831209612800135041402114721

311332513441363037693957

31.032.534.536.538.040.0

447446914979526854855733

45.047.750.353.055.658.3

.39

.38

.38

.40

.41

.43

161616161818

782382318638905394569865

BurnhamCommercial-Lancaster,PA

www.burnhamcommercial.comPhone: �-888-791-3790

8