UV Power Flood - Farnell

8
Order code: EQLED029 UV Power Flood User Manual

Transcript of UV Power Flood - Farnell

Order code: EQLED029

UV Power FloodUser Manual

www.prolight.co.uk UV Power Flood User Manual 2

Safety advice

WARNINGFOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CARE-FULLY BEFORE YOUR INITIAL START-UP!• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.

• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.

• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessaryfortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.

• Pleasenotethatdamagescausedbyusermodificationstothisequipmentarenotsubjecttowarranty.

IMPORTANT:The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONSIfthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageandthewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.

Donotendangeryourownsafetyandthesafetyofothers!

Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.

CAUTION!KEEP THIS EQUIPMENT AWAY FROM RAIN, MOISTURE AND LIQUIDS

CAUTION! TAKE CARE USING THIS EQUIPMENT!HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!!

• Neverletthepowercablecomeintocontactwithothercables.Handlethepowercableandallmainsvoltageconnectionswithparticularcaution!

• Neverremovewarningorinformativelabelsfromtheunit.

• Donotopentheequipmentanddonotmodifytheunit.

• Donotconnectthisequipmenttoadimmerpack.

• Donotswitchtheequipmentonandoffinshortintervals,asthiswillreducethesystem’slife.

• Onlyusetheequipmentindoors.

• Donotexposetoflammablesources,liquidsorgases.

• Alwaysdisconnectthepowerfromthemainswhenequipmentisnotinuseorbeforecleaning!Onlyhandlethepower-cablebytheplug.Neverpullouttheplugbypullingthepower-cable.

• Makesurethattheavailablemainssupplyvoltageisbetween100~240VAC,50/60Hz.

• Makesurethatthepowercableisnevercrimpedordamaged.Checktheequipmentandthepowercableperiodically.

• Iftheequipmentisdroppedordamaged,disconnectthemainspowersupplyimmediatelyandhaveaqualifiedengineerinspecttheequipmentbeforeoperatingagain.

• Thisunitisnotintendedforfixedinstallation.

• Iftheequipmenthasbeenexposedtodrastictemperaturefluctuation(e.g.aftertransportation),donotconnectpowerorswitchitonimmediately.Thearisingcondensationmightdamagetheequipment.Leavetheequipmentswitchedoffuntilithasreachedroomtemperature.

• Ifyourproductfailstofunctioncorrectly,stopuseimmediately.Packtheunitsecurely(preferablyintheoriginalpackingmaterial),andreturnittoyourProLightdealerforservice.

• Onlyusefusesofsametypeandrating.

• Repairs,servicingandpowerconnectionmustonlybecarriedoutbyaqualifiedtechnician.THISUNITCONTAINSNOUSERSERVICEABLEPARTS.

• Thislightingfixtureisforprofessionaluseonly-itisnotdesignedfororsuitableforhouseholduse.Theproductmustbeinstalledbyaqualifiedtechnicianinaccordancewithlocalterritoryregulations.Thesafetyoftheinstallationistheresponsibilityoftheinstaller.Thefixturepresentsrisksofsevereinjuryordeathduetofirehazards,electricshockandfalls.

• Warning!RiskGroup2LEDproductaccordingtoEN62471.Donotviewthelightoutputwithopticalinstrumentsoranydevicethatmayconcentratethebeam.

• WARRANTY:Oneyearfromdateofpurchase.

www.prolight.co.uk UV Power Flood User Manual 3

Product overview & technical specifications

ThispowerfulUVFloodisloadedwith24x3WLEDsproducingstrongblacklighteffects.Thefrontofthehousingismanufacturedwithacurveddesigntogivemaximumcoveragefromthiscompactunit.BuiltinfeaturesincludeDMX,soundactiveandmanualmodes.

• 24x3WUVLEDs

• Beamangle:60°

• Ultravioletwavelength:395nm

• 4kHzrefreshrate

• DMXchannels:8

• Auto,soundactiveandmaster/slavemodes

• 0-100%dimmingandvariablestrobe

• Suppliedwithhangingbracket

• 4pushbuttonmenuwithLEDdisplay

• IECpowerinput

• 3-PinXLRinput/output

• Fancooled

UV Power Flood

Specifications UV Power Flood

Powerconsumption 80W

Powersupply 100~240V,50/60Hz

Fuse F3A250V

Dimensions 230x353x122mm

Weight 2.3kg

Ordercode EQLED029

230mm

353mm 122mm

DMX INPUT DMX OUTPUT MENU UP DOWN ENTER POWER INPUT: 100-240V~50/60Hz

POWER CONSUMPTION: 80W (max.)

FUSE: F3A 250V

www.prolight.co.ukUV Power Flood

03 02 060504 07 01 08

01-Earthpoint

02-LEDdisplay

03-Functionbuttons

04-DMXinput

05-DMXoutput

06-IECpowerinput

07-FuseF3A250V

08-Hangingbracketadjustableknob

Inthebox:1 x fixture, 1 x power cable & 1 x user manual

www.prolight.co.uk UV Power Flood User Manual 4

Operating instructionsOperating instructions

MENU

U 0 0 1 UV dimmerU 0 0 0

U 2 5 5

S E 0 1 Strobe modeS E 0 1

S E 1 6

S L A u Slave mode

d 0 0 1 DMX address settingd 0 0 1

d 5 1 2

A U 0 1 Auto mode

S U 0 1 Sound mode

DMX mode:

OperatinginaDMXcontrolmodeenvironmentgivestheuserthegreatestflexibilitywhenitcomestocustomisingorcreatingashow.Inthismodeyouwillbeabletocontroleachindividualtraitofthefixtureandeachfixtureindependently.

ToaccesstheDMXaddressmode,pressthe“MENU”buttononthesideoftheunittoshowd001ontheLEDdisplay.Nowpressthe“ENTER”buttonandusethe“UP”and“DOWN”buttonstosettherequiredDMXaddress.Pressthe“ENTER”buttontoconfirmthesetting.Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

8 channel mode:

Channel Value Function

CH1 000-255 Masterdimmer(0-100%)

CH2 000-255 Strobe(slow-fast)

CH3000-125 Auto

126-255 SoundActive

CH4 000-255 Speed(slow-fast)

CH5 000-255 UVdimmerrow1(0-100%)

CH6 000-009 UVdimmerrow2(0-100%)

CH7 010-099 UVdimmerrow3(0-100%)

CH8 100-129 UVdimmerrow4(0-100%)

www.prolight.co.uk UV Power Flood User Manual 5

Operating instructions

Master/slave mode:

Tosetthemasterunitselectyourdesiredprogram(auto,soundactive,strobeorUVdimming).Tosettheotherunitsinslavemode,pressthe“MENU”buttononthefrontoftheunittoshowSLAuontheLEDdisplay.Pressthe“ENTER”buttontoconfirmthesetting.Theunitwillnowruninsequencewiththemasterunit.Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

PleaseensurethatallslaveunitsaresettothesameDMXchannelmodeasthemasterunit.

Auto mode:

Toaccesstheautomode,pressthe“MENU”buttonontherearoftheunittoshowAU01ontheLEDdisplay.Pressthe“ENTER”buttontoconfirmthesetting. Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

Sound mode:

Toaccessthesoundmode,pressthe“MENU”buttonontherearoftheunittoshowSU01ontheLEDdisplay.Pressthe“ENTER”buttontoconfirmthesetting.

Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

Strobe mode:

Toaccessthestrobemode,pressthe“MENU”buttononthesideoftheunittoshowSE01ontheLEDdisplay.Nowpressthe“ENTER”buttonandusethe“UP”and“DOWN”buttonstochoosebetweenSE01~SE16.Pressthe“ENTER”buttontoconfirmthesetting.

Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

Value: 01 - 16 (01 = slow strobe speed, 16 = fast strobe speed)

UV dimming mode:

ToaccesstheUVdimmingmode,pressthe“MENU”buttononthesideoftheunittoshowU001ontheLEDdisplay.Nowpressthe“ENTER”buttonandusethe“UP”and“DOWN”buttonstoadjusttheUVbrightnessbetweenU000~U255.Pressthe“ENTER”buttontoconfirmthesetting.Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

www.prolight.co.uk UV Power Flood User Manual 6

Setting the DMX address:

TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachfixturerequiresa“startaddress”from1-512.Afixturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannelindicatedbythestartaddress.Forexample,afixturethatoccupiesoruses7channelsofDMXandwasaddressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthechainstartsat107.

DMX 512:

DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligentfixturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothefixture.DMXdataissentasserialdatathattravelsfromfixturetofixtureviatheDATA“IN”andDATA“OUT”XLRterminalslocatedonallDMXfixtures(mostcontrollersonlyhaveadata“out”terminal).

DMX linking:

DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogetherandoperatefromasinglecontroller,aslongasallfixturesandthecontrollerareDMXcompliant.ToensureproperDMXdatatransmission,whenusingseveralDMXfixturestrytousetheshortestcablepathpossible.TheorderinwhichfixturesareconnectedinaDMXlinedoesnotinfluencetheDMXaddressing.Forexample;afixtureassignedtoaDMXaddressof1maybeplacedanywhereinaDMXline,atthebeginning,attheend,oranywhereinthemiddle.WhenafixtureisassignedaDMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,nomatterwhereitislocatedintheDMXchain.

DATA cable (DMX cable) requirements (for DMX operation):

ThisfixturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,seeimagebelow.

Also remember that DMX cable must be daisy chained and cannot be split.

DMX setup

FurtherDMXcablescanbepurchasedfromallgoodsoundandlightingsuppliersorProLightConceptsdealers.Pleasequote:

CABL10 – 2mCABL11 – 5mCABL12 – 10m

www.prolight.co.uk UV Power Flood User Manual 7

Notice:

Besuretofollowthediagramsbelowwhenmakingyourowncables.DonotconnectthecablesshieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRsoutercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.

Special note:

Line termination:

Whenlongerrunsofcableareused,youmayneedtouseaterminatoronthelastunittoavoiderraticbehaviour.

Using a cable terminator will decrease the possibilities of erratic behaviour. (3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)

5-pin XLR DMX connectors:

Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRfixturesmaybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.

Terminationreducessignaltransmissionproblemsandinterference.itisalwaysadvisabletoconnectaDMXterminal,(resistance120Ohm1/4W)betweenpin2(DMX-)andpin3(DMX+)ofthelastfixture.

5-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)Pin 4: N/CPin 5: N/C

3-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)

3-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)

5-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)Pin 4: N/CPin 5: N/C

DMX setup

www.prolight.co.uk UV Power Flood User Manual 8

WEEE notice

Correct Disposal of this Product (Waste Electrical & Electronic Equipment)

(Applicable in the European Union and other European countries with separate collection systems)

Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedofwithotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtotheenvironmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromothertypesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.

Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheirlocalgovernmentoffice,fordetailsofwhereandhowtheycantakethisitemforenvironmentallysaferecycling.

Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthepurchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.