Using Installer Toolkit for Installation Efficiency · 2019. 12. 18. · 10/12/2016 10 19 | © 2016...
Transcript of Using Installer Toolkit for Installation Efficiency · 2019. 12. 18. · 10/12/2016 10 19 | © 2016...
10/12/2016
1
Using Installer Toolkit for Installation Efficiency
Enphase Learning and Development
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 2
• Upon completion of this presentation you should be able
to…
• Describe Installer Toolkit benefits
• Describe the purpose of Envoy AP Mode
• Differentiate between “Connect to an Envoy” features and
“View Systems” features
Learning Objectives
10/12/2016
2
Installer Toolkit Benefits
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 4
• Connect to Envoy
• Wirelessly connect to an Envoy
to verify installation
• Set Grid Profiles
• Configure Metering
• Leave the job site knowing the
installation was a success
Faster Onsite Verification
10/12/2016
3
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 5
Faster Enlighten Activations
• Build, Scan and Sync
• Build your virtual arrays and scan microinverter serial numbers
with your mobile device’s camera
• Sync all system information,
and microinverter
serial numbers to Enlighten
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 6
Communication Protocols
10/12/2016
4
Getting Started
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 8
• iOS device running iOS 7.0 or higher
• IPhone 4 or later or iPod Touch 5th generation or later
• Android 4.2 or higher
• Enphase Installer Toolkit app installed on the device
Required Components – Installer Toolkit App
10/12/2016
5
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 9
• Enlighten login to required to access
application
• Work offline after initial login
Required Components – Enlighten Account
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 10
Required Components – Envoy-S With Built-in Wi-Fi
10/12/2016
6
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 11
• Scan using your phone’s camera
• Sync microinverter serial numbers
with Enlighten
Optional – Scanning and Syncing
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 12
• Connect to an Envoy
• Verify successful installation
• View Systems
• Expedite Enlighten system activation process
• App Menu
• Find Installer Toolkit features/tasks
Installer Toolkit Home
10/12/2016
7
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 13
Application Menu
• Easy access to Installer
Toolkit features and tasks
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 14
• Scanner: Select default scanning method
• Enlighten Connection: Turn off Installer
Toolkit communication with Enlighten
• Envoy Resources: Download the most recent
software to the Envoy, download help files,
download grid profiles and set auto-download
for software and help files
• About: Toolkit version and links to additional
information on Enphase.com
• Support: Email Installer Toolkit database to
Enphase Support for troubleshooting and
delete previously downloaded Envoy-S
updates.
Settings
10/12/2016
8
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 15
• View Educational Videos
• You may also be prompted to view these
videos from within the application
• Videos are also available directly under
Support > Training on Enphase.com
Video Library
Connect to Envoy
10/12/2016
9
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 17
Connect to Envoy
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 18
• Enable AP mode on the Envoy by
briefly pressing the Envoy AP Mode
button on the front of the Envoy
• The AP Mode LED will turn green
when the Envoy is in AP Mode
Activate Envoy AP Mode
10/12/2016
10
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 19
• Select the Envoy from the list of
available Wi-Fi networks on your mobile
device
• Match the last six digits with the serial
number on the Envoy (Envoy_XXXXXX)
Connect to Envoy Network
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 20
• Connect to An Envoy
• Verify successful installation
• Connect directly to an Envoy
• View Systems
• Expedite Enlighten system activation process
• View pending activations in Enlighten
Connect to Envoy
10/12/2016
11
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 21
• Enter the number of microinverters that you
have installed
• Scanned serial numbers will be auto-
populated
Enter Number of Microinverters
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 22
• Searches the powerline for microinverters
• Scan runs for 30 minutes or until expected number
of microinverters are found
Start Device Scan
10/12/2016
12
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 23
• Start a scan/rescan microinverters as desired
• Tap “Scan Inactive” > “Start Scan” to begin
• Note that the Scan Duration is administrable
• More Options provides opportunity to
prioritize device scanning above any other
activities for the priority duration period
• Useful for large sites
• Useful for sites experiencing problems discovering
devices with normal scan
Device Scan
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 24
• Top Section
• Production metering
• Current and lifetime production values
• Middle Section
• Enlighten monitoring
• Bottom Section
• Microinverter reporting
Envoy Overview Screen
10/12/2016
13
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 25
• Envoy-S Standard
• Current and lifetime production values
• Envoy-S Metered
• Production readings
• Envoy-S Metered with Consumption
• Production and Consumption readings
Top Section: System Production
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 26
• Connection to Enlighten
• Date and time of last report
• Connection method
Middle Section: Enlighten Monitoring
10/12/2016
14
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 27
• Microinverters Detected
• Expected number of microinverters
detected
• Microinverters Communicating
• Expected number of microinverters
communicating
• Powerline signal strength
• Grid Profile
• Select and apply appropriate grid profile
• Producing Power
• Expected number of microinverters
producing power & wattage
Bottom Section: Microinverters
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 28
• List of detected
microinverters by serial
number
• Discovered by device scan or
provisioned using Installer
Toolkit
• Detected/Non-detected
status
• Status indicator
• Microinverter details
Microinverters: All
10/12/2016
15
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 29
• Comm Tab: Number of
microinverters that
are/aren’t communicating
• Profile Tab: Grid profile
applied
• Power Tab: Microinverters
producing power
Microinverters: Status
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 30
• Applies to areas that
have specific regulatory
specifications
• Set country regulatory
spec
• Set appropriate grid
profile
• tap “Apply Grid Profile”
Setting Grid Profiles
10/12/2016
16
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 31
• View Active and Deleted microinverters
• Delete microinverters from the
database
• Search for existing microinverters
• Restore previously deleted
microinverters to the database
Microinverters: Manage
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 32
• Date and time of last report
• Performance
• Diagnostics
• Meter readings (if applicable)
• Connection method
• Wi-Fi
• Cellular
• Ethernet
• Two report settings
• Standard
• Low bandwidth
Enlighten Monitoring
10/12/2016
17
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 33
• View daily and lifetime
system consumption
• Configure Consumption
Metering
Meters
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 34
• About This Envoy: Envoy serial number, version
and other related information
• Date & Time: Set date, time and time zone
• Events: View Envoy events such as Grid Profile
propagation
• Connection to Enphase Support: Open
connection to Enphase Support for
troubleshooting
More
10/12/2016
18
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 35
• When system setup is
complete and verified,
tap “Done” to view and
email a summary report
and disconnect from the
Envoy.
Summary Report
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 36
Summary Report
Date/time report was run
Grid profile information, microinverter
serial numbers and date, time, &
amount of last power report
System, Envoy and Meter
information
10/12/2016
19
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 37
Summary Report (Email .pdf)
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 38
A friend asks you why
he should use Installer
Toolkit. What do you
tell him?
10/12/2016
20
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 39
Describe the purpose
of Envoy AP Mode and
when it would be
appropriate to use it.
Viewing and Setting up Systems
10/12/2016
21
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 41
• View Systems
• View existing systems or add new systems
Installer Toolkit: View Systems
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 42
• The application retrieves pending
activations from Enlighten
• Tap the to add a new system activation
• Pull down on the screen to refresh the list
• Use the search icon to locate a system
Systems List
10/12/2016
22
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 43
• Contains information about the system,
including:
• Name and address of system
• Envoys associated with the system
• Arrays associated with the system
• The information icon displays owner
and address
• Tap Edit to update information on this
screen
System Overview Screen
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 44
• Add a new virtual array by tapping
the “+” icon next to “Arrays”
Adding an Array
10/12/2016
23
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 45
• The array details are similar to that
provided in the Enlighten Array Builder
• Required:
• Envoy serial number
• Array name
• Default Values:
• Size
• Orientation
• Tilt & Azimuth
Adding an Array
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 46
• Select from the list of
detected Envoys
• OR tap “Add New Envoy”
to scan the Envoy’s
barcode (recommended) or
manually type in the serial
number
Adding an Envoy to the Array
10/12/2016
24
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 47
• Tap on any array name or tap "Scan" to
begin the microinverter scanning
process
Scanning Microinverter Serial Numbers
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 48
• To start the scanning
process, tap the module
where you want to begin
• You will be prompted to
choose either the mobile
device camera or a
Bluetooth enabled barcode
scanner on the first scan
Scanning Microinverter Serial Numbers
10/12/2016
25
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 49
• Scan the barcode using the
mobile device camera or
Bluetooth scanner
• The microinverter serial
number will display in the
text box
• To move to the next
microinverter, tap the next
one you’d like to scan
Scanning Microinverter Serial Numbers
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 50
Paper Array Map for Scanning
10/12/2016
26
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 51
• To remove a module from the array, tap
the at the bottom-right of the
module
• Delete microinverter serial number
• Delete entire module
Deleting Microinverter Serial Numbers and Modules
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 52
• To speed up scanning, turn on auto-scan
mode at the bottom of the screen
• Auto-advance to the next module in the
row, left or right
Auto-Scan Mode
10/12/2016
27
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 53
• Microinverter serial numbers that are
removed are available for
reassignment
• Applies to any serial numbers
associated to the Envoy but do not
have a location in the array
Unassigned Serial Numbers
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 54
• At least one microinverter not assigned to
array
• Tap icon to see a list of unassigned serial
numbers
• Tap desired number to assign it
• Search for serial number(s) as needed
Assign Microinverter Serial Number
10/12/2016
28
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 55
• An orange alert appears on
the systems lists to let you
know which systems need to
be synced with Enlighten
Syncing with Enlighten
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 56
• Tap the Sync icon at the bottom of the
window to start the sync process
• Synching requires that you are logged
into Enlighten over an active Internet
connection
Syncing with Enlighten
10/12/2016
29
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 57
• Once syncing is complete,
you can view the
Enlighten Activation
Checklist
Syncing with Enlighten
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 58
1. What type of information can be accessed
through the “Connect to an Envoy” feature?
2. What type of information can be accessed
through the “View Systems” feature?
10/12/2016
30
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 59
• Video Support
• Accessible from within Installer Toolkit
and Enphase website
• Available for IOS and Android
• Multi-language
• Installer Toolkit Training Slide
Deck
• Enphase Installer Toolkit Operation
Manual • https://www2.enphase.com/global/files/Installer_Toolk
it_manual_EN.pdf
Resources
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 60
Upcoming Training Events
Visit enphase.com/events
10/12/2016
31
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 61
Upcoming Webinars
• Discover the Envoy-S and AC Combiner Box for Storage Readiness
• October 11, November 17
• Power Export Control with Enphase
• October 17
• Metering CT Installation Tips and Tricks
• October 20, November 8, November 28
• Enlighten Manager for Customer Care
• October 25
• Installer Toolkit for Installation Efficiency
• November 9
| © 2016 Enphase Energy, Inc. | CONFIDENTIAL | For internal use only 62
THANK YOU
10/12/2016
32