MULTIPORTER – your capable assistent when dealing with NMEA2000 network development. A flexible solution which does not just save your installation space and time – it's perfect for anybody, either for experienced people or for absolute beginners who wants to set up their own NMEA2000 network quickly. 'Small, but what a skills' – up to 5 standard NMEA2000 ports are integrated into the MULTIPORTER, waiting for getting connected with several devices. The MULTIPORTER has an integrated interface for the power supply of your vessel as well. Furthermore, built-in LEDs provide you with information, like the given voltage or the data flow over the CAN-Bus. Due to the pluggable jumper on two terminal resistors, a flexible technical configuration is always possible. In addition to that, all of that is boxed in its own robust IP67 certified case, which protects the board from dust and water even under inconvenient circumstances. User's manual Features The MULTIPORTER gets powered by the power supply voltage of your vessel Note: the admissible voltage of the connected devices must not be exceeded. The MULTIPORTER and all its connected devices are secured by a replaceable 5A safety fuse. Five ( 5-pole M12 plug-in connectors ) allow connecting up to five NMEA 2000-compatible devices. One built-in tension relief secures the power cord. Integrated LEDs provide information about voltage supply and data flow. The IP67 certified case protects the inner board from dust and splashing water Notes: admissible ambient temperature: -20°C bis +70°C ( -4 F to 158 F ) all specifications refer to measurements in testing environment (TA) of +25°C ( 77 F ) the power consumption of the MULTIPORTER accounts about 5mA and does not have to be considered in calculating the energy balance inside the network.

Transcript of User's manual - TechnoSpark– 1x user's manual Overwiew 1. Power LED (red) - bright – voltage...

Page 1: User's manual - TechnoSpark– 1x user's manual Overwiew 1. Power LED (red) - bright – voltage applied 2. Fuse 5A - replacable security fuse 3. 12V DC – board voltage supply. The

MULTIPORTER – your capable assistent when dealing with NMEA2000 networkdevelopment. A flexible solution which does not just save your installationspace and time – it's perfect for anybody, either for experienced people or forabsolute beginners who wants to set up their own NMEA2000 network quickly.'Small, but what a skills' – up to 5 standard NMEA2000 ports are integrated intothe MULTIPORTER, waiting for getting connected with several devices. TheMULTIPORTER has an integrated interface for the power supply of your vessel aswell. Furthermore, built-in LEDs provide you with information, like the givenvoltage or the data flow over the CAN-Bus.Due to the pluggable jumper on two terminal resistors, a flexible technicalconfiguration is always possible.In addition to that, all of that is boxed in its own robust IP67 certified case,which protects the board from dust and water even under inconvenientcircumstances.

User's manual

Features

– The MULTIPORTER gets powered by the power supply voltage of your vessel Note: the admissible voltage of the connected devices must not beexceeded.

– The MULTIPORTER and all its connected devices are secured by a replaceable5A safety fuse.

– Five ( 5-pole M12 plug-in connectors ) allow connecting up to five NMEA2000-compatible devices.

– One built-in tension relief secures the power cord.– Integrated LEDs provide information about voltage supply and data flow.– The IP67 certified case protects the inner board from dust and splashing

water

Notes:– admissible ambient temperature: -20°C bis +70°C ( -4 F to 158 F )– all specifications refer to measurements in testing environment (TA) of +25°C ( 77 F )– the power consumption of the MULTIPORTER accounts about 5mA and does not have to be

considered in calculating the energy balance inside the network.

Page 2: User's manual - TechnoSpark– 1x user's manual Overwiew 1. Power LED (red) - bright – voltage applied 2. Fuse 5A - replacable security fuse 3. 12V DC – board voltage supply. The

Package contents

– 1x MULTIPORTER – five NMEA2000 M12 ports, waterproof cable bushing– 1x spare safety fuse 5A – 1x user's manual

Overwiew

1. Power LED (red) - bright – voltage applied2. Fuse 5A - replacable security fuse 3. 12V DC – board voltage supply. The inscription on the curcuit board

indicates the polarity. 4. J1 and J2 – plug-in jumper to active or deactivate teminal resistors.5. CAN LED (green) - faintly - CAN-Bus is active, there is no NMEA2000 data

transmittedCAN LED (green) - bright – CAN-Bus is active, data traffic avalable

6. CAN0 - extension port 17. CAN4 - extension port 2

Size

CAN LED

Fuse 5A

12V DCCAN4

J2

Power LED

J1

CAN0

Page 3: User's manual - TechnoSpark– 1x user's manual Overwiew 1. Power LED (red) - bright – voltage applied 2. Fuse 5A - replacable security fuse 3. 12V DC – board voltage supply. The

Building up a NMEA2000 network using the MULTIPORTER is quite easy.To create an easy and adequate network, the jumper has to be inserted over thetwo terminal resistors bridge J1 and J2 in order to activate them.The network is now successfully established and you can feel free to connect upto five NMEA2000-capable devices and sensors.The five plug-in connectors are internly merged in a bus from CAN0 to CAN4 andare terminated with resistors.By specifically targeting and activating of the terminal resistors, it ispossible to extend your MULTIPORTER with two backbones.Note that the CAN0 to CAN4 connectors should be used for the backbone extensionexclusively.

In the following, various options and examples for technical configurations ofthe MULTIPORTER will be presented. * Using and connecting all five plug-in connerctors is not necessarily required for a successfulnetwork establishment.

Example 1

The easiest way to establish a NMEA2000 network with the MULTIPORTER.The internal terminal resistors J1 and J2 are activated by a jumper.

Note: you can connect five devices or sensors at the maximum. The whole power consumption must not exceed 4A. Detailed information about power consumption ofthe respective devices can be taken from the manufacturer specifications.

Power

DropDrop

Drop

Drop Drop

Page 4: User's manual - TechnoSpark– 1x user's manual Overwiew 1. Power LED (red) - bright – voltage applied 2. Fuse 5A - replacable security fuse 3. 12V DC – board voltage supply. The

Example 2

The NMEA200 network – as decribed above ( Example 2) – gets broadened by anadditional backbone.

In that case, both terminal resistors J1 and J2 stay disabled by not using ajumper at all. Both outgoing cords must be terminated by a terminal resistor.Both cords can be extended by some T-connectors.

Note: The combined length of both backbones must not exceed the admissiblelenth. The whole power consumption must not exceed 4A.

Terminator T-ConnectorBackbone

Dro

p

Drop

Drop Drop

Drop

Power

Page 5: User's manual - TechnoSpark– 1x user's manual Overwiew 1. Power LED (red) - bright – voltage applied 2. Fuse 5A - replacable security fuse 3. 12V DC – board voltage supply. The

Example 3

The NMEA200 network – as decribed above ( Example 2) – gets broadened by anadditional backbone.

In that case, both terminal resistors J1 and J2 stay disabled by not using ajumper at all. Both outgoing cords must be terminated by a terminal resistor.Both cords can be extended by some T-connectors.

Note: The combined length of both backbones must not exceed the admissiblelenth. The whole power consumption must not exceed 4A.

Terminator

Terminator

Backbone

Backbone

Power

Drop Drop

Drop

Page 6: User's manual - TechnoSpark– 1x user's manual Overwiew 1. Power LED (red) - bright – voltage applied 2. Fuse 5A - replacable security fuse 3. 12V DC – board voltage supply. The

Example 4

In the event of an intentional exceedance of the power consumption, you will need a second power connection.

Therfore you may combine two MULTIPORTER.This is possible by inserting an appropriate power isolator.As described above ( Example 3 ) - both terminal resistors J1 and J2 staydisabled by not using a jumper at all.

12V DC

Backbone

Bac

kbo

ne

Power-Isolator

Bac

kbo

ne

MULTIPORTER 1

MULTIPORTER 2

Page 7: User's manual - TechnoSpark– 1x user's manual Overwiew 1. Power LED (red) - bright – voltage applied 2. Fuse 5A - replacable security fuse 3. 12V DC – board voltage supply. The

Important notices

All rights are reserved. The contents of this manual may not be transferred or copied withoutthe expressed written permission of Technospark Systems. All other trademarks are the propertyof their respective owners. The MULTIPORTER is intended for use in a marine environment,primarily for below deck use. If the unit is to be used in a more severe environment, such usemay be considered misuse under the seller’s warranty.The MULTIPORTER has been certified to comply with the European directive for Electro-MagneticCompatibility (EN60945), and is appropriately CE marked. Operation of the unit should be inconjunction with appropriate CE approved shielded connectors and cabling used in accordance withthe CE directive EN60945. Any EMC related issues should be reported to Technospark Systemsimmediately to allow the company to rectify or resolve EMC related problems in accordance withits obligations under EN60945.If the unit is connected such that compliance failure occursbeyond the company’s control, the company shall not be held responsible for compliance failureuntil suitable EMC guidelines for connection are seen to have been taken.

The products described in this manual and the specifications thereof may be changed withoutprior notice. To obtain up-to-date information and/or specifications, contact TechnosparkSystems or visit the company portal on web site (www.technospark.de)

Technospark Systems will not be liable for infringement of copyright, industrial property right,or other rights of a third party caused by the use of information or drawings described in thismanual. Technospark Systems will not be held responsible for any damage to the user that mayresult from accidents or any other reasons during operation of the user’s unit according to thisdocument.

NMEA® und NMEA2000® are registered trademarks of National Marine Electronics Association

Dispose of this product in accordance with the WEEE Directive. The product should be taken to a registered establishment for the disposal of electronic equipment

Page 8: User's manual - TechnoSpark– 1x user's manual Overwiew 1. Power LED (red) - bright – voltage applied 2. Fuse 5A - replacable security fuse 3. 12V DC – board voltage supply. The