D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 1 ED-0005-OT-130-B MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G D-M-E Smart Series Mainframes User’s Manual D-M-E Company

Transcript of User’s Manual D-M-E Company...D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 4...

Page 1: User’s Manual D-M-E Company...D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 4 ED-0005-OT-130-B SAFETY D-M-E Company products have been designed to be safe and simple

D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 1ED-0005-OT-130-B

MFP1G, MFP1G1, MFPR2G,MFFPR2G & MFHP1G

D-M-E Smart Series

Mainframes

User’s ManualD-M-E Company

Page 2: User’s Manual D-M-E Company...D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 4 ED-0005-OT-130-B SAFETY D-M-E Company products have been designed to be safe and simple

D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 2ED-0005-OT-130-B

Copyright D-M-E Company 1999-2000. All rights reserved.

D-M-E Company products are covered by USA and foreign patents, issued and pending.Information in this publication supersedes that in all previously published material. Specificationsand any changes are reserved.

Printed in the United States of America

D-M-E Company29111 Stephenson HighwayMadison Heights, MI 48071

D-M-E Company and D-M-E are registered trademarks of D-M-E Company.

Page 3: User’s Manual D-M-E Company...D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 4 ED-0005-OT-130-B SAFETY D-M-E Company products have been designed to be safe and simple

D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 3ED-0005-OT-130-B

WARRANTY

D-M-E Company warrants that this product will be free from defects in materials and workmanshipfor a period of one (1) year from the date of shipment. If any such product proves defective duringthis warranty period, D-M-E Company, at its option, will either repair the defective product withoutcharge for parts and labor, or will provide a replacement in exchange for the defective product.

This warranty shall not apply to any defect, failure or damage caused by improper use or improperor inadequate maintenance and care. D-M-E Company shall not be obligated to furnish serviceunder this warranty a) to repair damage resulting from attempts by personnel other than D-M-ECompany representatives to repair or service the product; b) to repair damage resulting fromimproper use or connection to incompatible equipment; or c) to service a product that has beenmodified or integrated with other products when the effect of such modification or integrationincreases the time or difficulty of servicing the product.

Page 4: User’s Manual D-M-E Company...D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 4 ED-0005-OT-130-B SAFETY D-M-E Company products have been designed to be safe and simple

D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 4ED-0005-OT-130-B

SAFETY

D-M-E Company products have been designed to be safe and simple to operate. As with anyelectronic equipment, you must observe standard safety procedures to protect both yourself andthe equipment.

To Prevent Injuries:• To avoid electrical shock or fire hazard, DO NOT apply voltage to a terminal that exceeds the

range specified for that terminal.

• To avoid electrical shock, make sure product is properly earth grounded. • To avoid mechanical injury, electrical shock or fire hazard, DO NOT operate this product with

covers or panels removed.

• To avoid mechanical injury, electrical shock or fire hazard, turn off power (circuit breaker)before inserting or removing modules.

• To avoid electrical shock or fire hazard, DO NOT operate this product when wet. • To avoid injury or fire hazard, DO NOT operate this product in an explosive atmosphere.

To Prevent Product Damage:• DO NOT operate this product from a power source that applies more than the voltages

specified.

• Replace 15 amp fuses in your modules with 10 amp or less fuses for use in 10 ampmainframes.

Page 5: User’s Manual D-M-E Company...D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 4 ED-0005-OT-130-B SAFETY D-M-E Company products have been designed to be safe and simple

D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 5ED-0005-OT-130-B

D-M-E Smart Series

Mainframes

MFP1G, MFP1G1, MFPR2G,MFFPR2G & MFHP1G

GENERAL DESCRIPTION

This manual describes the installation,operation, servicing and safety procedures forthe D-M-E Smart Series Mainframe.

The D-M-E Smart Series Mainframe isdesigned as a closed-loop power distributionand temperature controlling system. When itis used in conjunction with D-M-E temperaturecontrols, this system provides the user withpremier temperature control capabilities.D-M-E offers several different types oftemperature control modules, one to fit everybudget. These temperature controls providethe operator with superb operator interface,ease of use, and simplicity. The MFP1Gmainframe will be used for the examples inthis manual. See Figure 12 in the back of thismanual for details on all other models.

The power output / thermocouple inputconnector is located on the top of the MFP1Gunit, and is designed to deliver 10 Amps ofcurrent. Depending on the model youpurchased, 10, 15 or 30 amps of current canbe delivered.

Figure 1 - Power / ThermocoupleConnector Used On The MFP1G (10 Amps

Maximum Current)

FEATURES

Each mainframe is constructed with heavy-duty steel framework. The MFFPR2G &MFHP1G units also contain a built-in coolingfan. Interfacing is accomplished through apower output cable and a thermocouple inputcable. D-M-E can also supply specialtemperature control systems & cables to meetyour requirements.

WIRING THE UNIT

Unless otherwise specified, all Smart Seriesmainframes operate at a 240 Volts AC inputpower. The MFP1G1 unit is wired to operateat a 120 VAC.

The CKPTM1 connector is used to connectpower & thermocouple wires from a heaterdirectly to the mainframe. (See below)

Figure 2 - CKPTM-1 Connector

Figure 3 - Wiring Diagrams For CKPT StyleConnectors

Page 6: User’s Manual D-M-E Company...D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 4 ED-0005-OT-130-B SAFETY D-M-E Company products have been designed to be safe and simple

D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 6ED-0005-OT-130-B

UNPACKING AND INSPECTION

1. After unpacking, inspect yourmainframe and check for any damagethat may have occurred duringshipment.

2. Check the circuit breaker for damage. 3. Check for proper operation of circuit

breaker by flipping breaker on and offwith no voltage applied.

4. Check power output connector and

thermocouple input connector for anyphysical damage.

5. Check AC input power wiring.

SAFETY

SERVICE AND INSTALLATION OF THISEQUIPMENT SHOULD ONLY BEPERFORMED BY QUALIFIED SERVICEPERSONNEL FAMILIAR WITH HIGHVOLTAGE ELECTRICAL CIRCUITS.

NOTE: FOLLOW ALL NATIONAL ANDLOCAL ELECTRICAL CODES WHENCONNECTING THIS EQUIPMENT.

WARNING: Before removing the back panelof this unit, remove the AC power input cable.DO NOT apply power to this cable or the unitwhen the back panel is removed.

DANGER: DO NOT connect AC power inputcord to your in-plant power distribution systemuntil mainframe back panel is securely inplace.

DANGER: DO NOT attempt to insert lowervoltage modules into high voltage zones.Certain catastrophic failure of the module andpossible injury to humans in the area mayresult.

DANGER: On models equipped with amodule rejection system, DO NOT attempt todefeat the rejection scheme as certaincatastrophic failure of the module and possibleinjury to humans in the area may result. DONOT remove the rejection rod on any modulesor mainframes. (See figures 4 & 5)

Figure 4 - Rejection Rod on Low VoltageModules (DO NOT Remove)

High power mainframes are equipped with asafety rejection rod to prevent accidentalinsertion of non-compatible modules and toprevent short circuits. DO NOT remove therejection rod, as certain catastrophic failure willoccur. (See figure 5)

Figure 5 - Rejection Rod In MFHP1G HighPower Mainframe (DO NOT Remove)

DANGER - HIGH VOLTAGE

If it becomes necessary to service thisequipment after AC input connections arecompleted, make sure that your in-plant powerdisconnect is secured in the “OFF” position bymeans of a padlock or other mechanismprovided by the manufacturer of thedisconnect. A “LOCK-OUT” mechanism isrecommended to prevent power from beingaccidentally turned-on.

Page 7: User’s Manual D-M-E Company...D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 4 ED-0005-OT-130-B SAFETY D-M-E Company products have been designed to be safe and simple

D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 7ED-0005-OT-130-B

INSTALLATION

1. You are installing a piece of electronicequipment that is delicate and shouldnot be subjected to any physical orenvironmental abuse. Select a cool,dry, well-ventilated, environmentallyclean location, away from heat,moisture and liquid carrying lines, i.e.:water cooling hoses, hydraulic hoses,etc.

2. Mainframes are shipped from the

factory pre-wired 240 VAC. MFP1G1units are wired for 120 VAC input.

3. Select the input supply line wire size

according to national and your localelectrical codes. Refer to mainframeserial number label for amperagerating of the circuit breaker in yourmainframe.

a) Assemble your AC input

power supply line to the inputpower connector supplied withyour mainframe.

b) WARNING: Make sure thatthe chassis has been earthgrounded before applyingpower.

4. Make sure mainframe back panel is

securely in place before connectingpower to mainframe.

5. Route AC input cable to a branch

circuit (service) disconnect switch andattach leads to fused side of switch.Be sure ground lead is attached to agood earth ground.

6. Where required, insert appropriate

fuses in fused disconnect box. 7. Connect power & thermocouple cables

to mainframe and mold. 8. Refer to Module Specifications sheets

supplied with module for front panelcontrols and module operation for thespecific module being used.

WARNING: BEFORE APPLYING POWER,MAKE SURE ALL NATIONAL AND LOCAL

ELECTRICAL CODES HAVE BEENFOLLOWED AND ALL SAFETYPRECAUTIONS ARE TAKEN.

IMPORTANT: For mold wiring and heaterconnection information, refer to moldconnector-wiring diagram.

OUTPUT CURRENT LIMITATIONS

Each Smart Series mainframe is equippedwith a two-pole, fast-acting magnetic circuitbreaker, (see figure 6). This circuit breakerlimits the current in the mainframe andprotects the mainframe internal wiring. Theoutput current limitation for each frame isdetermined by the size of the circuit breakerinstalled in the mainframe. DO NOT use alarger amperage breaker than what yourmainframe was designed for. Serious damagecan occur.

MODEL NUMBER CIRCUIT BREAKERMFP1G 10 AMPMFP1G1 10 AMPMFPR2G 20 AMP

MFFPR2G 30 AMPMFHP1G 30 AMP

WARNING: BEFORE INSERTING ORREMOVING ANY MODULES FROM THEMAINFRAME, TURN THE POWER “OFF” BYFLIPPING THE CIRCUIT BREAKERHANDLE TO THE “OFF” POSITION.

Figure 6 - Circuit Breaker Panel

Page 8: User’s Manual D-M-E Company...D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 4 ED-0005-OT-130-B SAFETY D-M-E Company products have been designed to be safe and simple

D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 8ED-0005-OT-130-B

MAINFRAME WIRING

Provided in this booklet, is a schematic ofstandard 1 & 2 zone mainframes & 1 zonehigh power mainframe (see figures 13 & 14).Refer to edge connector for printed circuitboard connections (see figure 7). Note thatthe AC input power contact’s #6 and #7 on theedge card connector are specificallydesignated for 240 VAC (120 VAC in MFP1G1units).

The module output power is connected to themainframe power output connector, located onthe top of the mainframe, via contact’s #4 and#5 of the edge card connector. (See figure 7)

Figure 7 - Rear View of Edge CardConnector

Thermocouple (T/C) input is accomplished byconnecting a thermocouple signal to the inputconnector located on the top of the mainframe,(see figure 1). The T/C signal is attached tothe appropriate module via T/C extensionwires connecting the T/C input connector tocontacts #1 and #2 on the appropriate moduleedge card connector. Refer to figure 7, andnote that thermocouples are connected tocontact #1 which is positive (white wire), andcontact #2 which is negative (red wire).

PIN ASSIGNMENTS OF THE EDGECARD CONNECTOR:

Please refer to figure 7 for location of pins.

Pin 1 From Thermocouple Positive (+)Pin 2 From Thermocouple Negative (-)Pin 3 (not used)Pin 4 To Heater LoadPin 5 To Heater LoadPin 6 From Applied Line VoltagePin 7 From Applied Line VoltagePin 8 From Earth Ground

TEMPERATURE CONTROL SYSTEMCONSIDERATIONS:

There are many factors to consider whenemploying a temperature control system. Allpower requirements should be examined tomake sure that the control system is matchedto the heaters that are used:

1. Are the heaters 240 VAC or 120 VAC? 2. What is the wattage of the heater? Is

the module’s output amperagecapability adequate for the heater tobe controlled?

3. Is the control system sized adequately

for all heaters that need to becontrolled?

TEMPERATURE CONTROL THEORYCONSIDERATIONS:

In any temperature control system, it isimportant to minimize the lag time between theheat source (heater) and the heat sensor(thermocouple). The lag time is the time ittakes for the heat to travel from the heater tothe thermocouple. It is very important to keepthe physical distance between the heater andthe thermocouple at a minimum. Best resultsare obtained when the heater andthermocouple are in an integral unit, such asD-M-E’s “HCTC” series heaters. The greaterthe distance between the heater andthermocouple, the greater the control error.

Make sure that the heater to be used hasadequate power (wattage) to elevate the

Page 9: User’s Manual D-M-E Company...D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 4 ED-0005-OT-130-B SAFETY D-M-E Company products have been designed to be safe and simple

D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 9ED-0005-OT-130-B

material to be heated to the desiredtemperature.

If you have any questions or require additionalinformation, contact your local D-M-Erepresentative.

CONNECTORS AND CABLES:

D-M-E inventories mold power cables andthermocouple cables that interface with 1 & 2zone mainframes, and 1 zone high powermainframes. See Figure 12. They are alsoavailable in special lengths on request.

TERMINAL MOUNTING BOXES:

D-M-E also inventories terminal mountingboxes to provide an easy and economicalmethod of mounting the power / thermocoupleconnectors on the mold.

ACCESSORIES TO COMPLETEYOUR MOLD DESIGN:

To complete your temperature control system,the following accessories are suggested:

♦ Mold power input & thermocouple outputconnector and panel mount base, (seefigure 8).

Figure 8 - Mold Power Input Connector

• Mold power cables in 10-foot or 20-footlengths (see figure 9).

Figure 9 - MPTC-10 Power & ThermocoupleCable

♦ Temperature control modules. NOTE:TEMPERATURE CONTROL MODULESARE NOT INCLUDED WITH THISMAINFRAME; THEY MUST BEORDERED SEPARATELY. One module isrequired for each zone of temperaturecontrol. Any of D-M-E’s standard 15 Amptemperature controllers will operate in the10 or 15 Amp mainframes. 30 Ampmodules are required for high powermainframes.

♦ For safety considerations, all unused

zones must be covered with blank panels.Use one D-M-E #MFBP10G blank panelfor every zone that is not used.

REPLACEMENT PARTS:

Replacement parts listed below:

CATALOGNUMBER DESCRIPTION

ABC10 10 Amp fuseABC15 15 Amp fuseAGC1 1 Amp fuseCBD10M 10 Amp Circuit BreakerCBD20M 20 Amp Circuit BreakerCBD30M 30 Amp Circuit BreakerCKF312G Edge card connector

kit (connector & 8 pins)MFBP10G Blank panel to cover

unused zonesRPM0044 Card guideRPM0046 Replacement pins for

edge card connectorRPM0048 Extraction tool for edge

card connector pins

Page 10: User’s Manual D-M-E Company...D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 4 ED-0005-OT-130-B SAFETY D-M-E Company products have been designed to be safe and simple

D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 10ED-0005-OT-130-B

Figure 10 - Edge Card Connector Kit,CKF312G (includes pins). Use RPM0046 to

order pins separately.

TROUBLESHOOTING:

If the fuses in a module clear upon initialpower up or the circuit breaker trips, the heateroutput is probably grounded or shorted.

FAN FUSES:

The MFFPR2G and the MFHP1G mainframesboth have 2 additional fuses located on thebackside of the rear connector panel. Thesefuses supply voltage to both wires of the fan.(1 fuse for each wire.) If the fan stops rotating,check these fuses. You can access the fusesby disconnecting the power and then removingthe back panel. DO NOT WIRE CONTROLZONES TO THESE FUSES. USE EXACTREPLACEMENT FUSES.

EUROPEAN CONFORMITY (CE)REQUIREMENTS:

Secure each DME module, at the top of themodule, to the mainframe, with a green 3MM x10MM screw that is supplied with eachmodule. Modules are secured to themainframe for grounding purposes and alsosatisfying CE requirements. When themodules are screwed down securely, they areCE compliant. NEVER REMOVE OR INSERTMODULES WHEN MAINFRAME CIRCUITBREAKER POWER IS ON.

Figure 11 - European CommunitiesConformity Requirement

CAUTION! FOR USERS OF THEMFP1G, MFP1G1, & MFPR2GMAINFRAMES

If you ordered an MFP1G, MFP1G1, or anMFPR2G mainframe, you must replace thestandard ABC15, 15 Amp fuses, supplied withyour DME modules, with ABC10, 10 Ampfuses. The connectors and wiring in thesemainframes are only rated for 10-Amp usage.If you use 15 Amp fuses in your modules, yourisk damage to the mainframe, the modules,and perhaps to persons who work near thisunit while it is in operation. Be safe byreplacing the fuses with ABC10 fuses.

RETURN POLICY:The D-M-E® 1 & 2 zone mainframes are warranted for 1year parts and labor, excluding fuses.

Contact D-M-E Customer Service for return authorizationfor repairs or warranties. Replacement parts are alsoavailable through the Customer Service Department.

D-M-E Customer Service

In U.S., West Coast: 1(323) 263-9261Elsewhere in U.S.: 1(800) 626-6653In Canada: 1(905) 677-6370

SERVICE CENTER U.S.A.

D-M-E WORLD HEADQUARTERS29111 STEPHENSON HIGHWAYMADISON HEIGHTS, MICHIGAN 48071PHONE: 1(800) 626-6653TELEFAX: 1(248) 398-6174

G-Series®, Smart Series®, Smart Start®, Selective Cycle®,and D-M-E® are all registered trademarks of D-M-ECompany.

Page 11: User’s Manual D-M-E Company...D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 4 ED-0005-OT-130-B SAFETY D-M-E Company products have been designed to be safe and simple

D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 11ED-0005-OT-130-B

Frame AC Power Inlet Power Output & T/C Input Power Input & T/C Output Power & T/C Cable

Frame AC Power Inlet Power Output T/C Input Power Input T/C Output Power Cable T/C Cable

Figure 12 –Mainframes, Connectors & Cables for All Mainframes

MODEL #

MFP1G11 Zone

10 Amp120V

MFP1G1 Zone

10 Amp240V

MFPR2G2 Zone

10 Amp/Z240V

MFFPR2G2 Zone

15 Amp/Z240V

MFHP1G1 Zone

30 Amp240V

Page 12: User’s Manual D-M-E Company...D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 4 ED-0005-OT-130-B SAFETY D-M-E Company products have been designed to be safe and simple

D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 12ED-0005-OT-130-B

Figure 13 - 1 & 2 Zone Mainframes Wiring Schematic

Page 13: User’s Manual D-M-E Company...D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 4 ED-0005-OT-130-B SAFETY D-M-E Company products have been designed to be safe and simple

D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 13ED-0005-OT-130-B

Figure 14 - 1 Zone High Power Mainframe Wiring Schematic

Page 14: User’s Manual D-M-E Company...D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 4 ED-0005-OT-130-B SAFETY D-M-E Company products have been designed to be safe and simple

D-M-E Company MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G Page 14ED-0005-OT-130-B

NOTES:

ECN’S:

ECN-0525 Feb 14, 2000Correct figure 5 to show pin inserted for position 3Correct figure 7 to show pin inserted for position 3Correct figure 10 to show pin for position 3Page 9, Table, change 7 pins to 8 pinsUpdate figures 13 & 14 to show correct Australian wire colors

APPROVAL:SENIOR PRODUCT ENGINEER: _____________________________ DATE: ______________

MANAGER OF ELECTRONICS: ______________________________ DATE: ______________