Urja Solutionsurjasolutions.com/pdf/Solar products.pdf · Solar Hybrid Inverter & UPS Features: 1....
Transcript of Urja Solutionsurjasolutions.com/pdf/Solar products.pdf · Solar Hybrid Inverter & UPS Features: 1....
Urja SolutionsSolar Charge Controller (Zero drop) SCC-03
With inbuilt intelligent changeoverWith socket & Mains cord
Specification:Model- SCC-03
Voltage- 12,24V
Current- 10,20,40,60A
Relay ON- 14.3/28.6V
Relay OFF- 11.5/23V
Full charge cut off – 14.5/29V
Indication:
1. Solar- It will glow when solar is connected
2. Charger ON- It will glow when charging starts
3. Relay ON- It will glow when relay is ON
Auto/Manual:
• Auto- Relay will on when it reaches at 14.3/28.6Volt, It will be in on position up to 11.5/23Volts
• Manual- above mentioned relay function do not work in manual mode
Specification:
Model- SCC-02
Voltage :12,24,36,48V
Current :10,20,40,60A
Relay ON :14.3/28.6V,………..
Relay OFF :11.5/23V,……………
Full charge cut off :14.5/29V,…………..
Indication & Readings:
1. Solar- It will glow when solar is connected
2. Charger ON- It will glow when charging starts
3. Relay ON- It will glow when relay is ON
4. Display- It will show solar voltage by using 3 digit
7 segment Display
Auto/Manual:
Auto -Relay will on when it reaches at
14.3/28.6,……..Volt, It will be in on position up to
11.5/23,……..Volts
Manual -Above mentioned relay function do not work in
manual mode
Three Phase Interleaved MPPT Boost Solar Charge Controller
Features & Specification
Features:1. 3 phase Interleaved Boost Charge controller
2. DSP based Rugged Design
3. Operating frequency - 20KHz X3 total 60KHz
4. Battery Charging mode - CC ,CV & float mode
5. Maximum Power Point Tracking6. Prevents Over-Charging7. Multi-stage battery charging8. Marine-Grade Hardware9. Overload Protected10. Over-Temperature Protected11. Temperature Compensation12. Automatic Fault Recovery
Specification:Model :SCCMPPT-01
Voltage :24,48V……….
Current :40,60A………..
Relay ON :28.8V,57.6………..
Relay OFF :23V,46……………
Full charge cut off :29V,58…………..
Readings:1. Battery Voltage,
2. Charging Current,
3. Total Unit Generated from Solar
Auto/Manual :Auto- Relay will on when it reaches at 28.8/57.6,……..Volt, It will be in on position up to 23/46,……..Volts
Manual- above mentioned relay function do not work in manual mode
DSP Sine Wave Inverter & UPSFeatures:1. Pure Sine Wave Out put.
2. DSP Technology.
3. No humming sound.
4. Smart charging.
5. Long battery life.
6. Compact Design.
7. DSP based very robust design which will not fail in any extreme
condition.
8. 20 KHz operating frequency while inverter and charging.
9. Cycle- Cycle current limiting which is an enhanced protection method
during short circuit and heavy load condition, Current limiting action will
take place instant tripping which will load to more reliability.
10. Protections against: Overload, Short circuit, Battery low, in all these
condition will be shown in the LCD display.
11. LCD Display for indicating various status of the system like Inverter ON
,Mains ON, Charging current, Over load, Battery Low. Input voltage,
Battery voltage, UPS/INV mode, Load in percentage etc.
12 Delayed inverter cut off for condition like battery low, over load, short
circuit etc, and this system will automatically restart from cut off after a
few seconds of buzzer beeps . The system will permanent cut off in the
error condition Exists after 4 restart.
13. Isolated Mains sensing which will ensure no electric shock from the
battery /PCB even if the Phase Neutral is reversed.
14. Inbuilt SMPS type charging .
15. Ideal for mixed load application.
Available Capacity:500VA,700VA, 850VA,1KVA @12V
DSP Sine Wave Inverter & UPSFeatures:1. Pure Sine Wave Out put.
2. DSP Technology.
3. No humming sound.
4. Smart charging.
5. Long battery life.
6. Compact Design.
7. DSP based very robust design which will not fail in any extreme condition.
8. 20 KHz operating frequency while inverter and charging.
9. Cycle- Cycle current limiting which is an enhanced protection method during short circuit and heavy load condition, Current limiting action will take place instant tripping which will load to more reliability.
10. Protections against: Overload, Short circuit, Battery low, in all these condition will be shown in the LCD display.
11. LCD Display for indicating various status of the system like Inverter ON ,Mains ON, Charging current, Over load, Battery Low. Input voltage, Battery voltage, UPS/INV mode, Load in percentage etc.
12 Delayed inverter cut off for condition like battery low, over load, short circuit etc, and this system will automatically restart from cut off after a few seconds of buzzer beeps . The system will permanent cut off in the error condition Exists after 4 restart.
13 Isolated Mains sensing which will ensure no electric shock from the battery /PCB even if the Phase Neutral is reversed.
14. Inbuilt SMPS type charging .
15. Ideal for mixed load application.
Available Capacity:1.5KVA,2KVA, 3KVA, 4KVA, 5KVA @ 24V, 36V & 48V
Solar Hybrid Inverter & UPSFeatures:1. Pure Sine Wave Out put
2. DSP Technology
3. LCD Display
4. Compact Design
Control switches:1. Inverter/ UPS switch
a. Inverter- Low voltage- 100V High Voltage- 270V AC
b. UPS-Low voltage- 170V High Voltage -270V AC
2. Charger Selection Switch
Mains charger OFF – Mains charger will be permanently OFF and Battery will charge only from solar
Mains/solar- In this mode both charger will work UP TO 13.8V, mains charger will turned OFF @ 13.8V automatically and only solar will work UPTO 14.3V
3.Auto/Manual Switch
Auto- This solar Hybrid inverter can provide power to the connected load by utilizing the PV power, Utility (Mains) power and battery power. When PV energy is good it will charge the connected batteries , when battery voltage reaches @14.3V Relay will turn ON and this inverter will convert power to the connected loads from solar and Batteries. When PV and Battery power is not sufficient for connected loads ( It means less than 11.5V) this inverter will source from the utility (mains) at the same time . When PV energy is not sufficient and Utility (mains) is failed, The System selects the Battery as source.
Manual-This inverter will work when mains failed.
Indication & Readings
1. Solar- It will glow when solar is connected .
2. Charger ON- It will glow when charging starts.
3. Relay ON- It will glow when relay is ON.
Available Capacity
500VA,700VA, 850VA,1KVA @12V &24V.
Solar Hybrid Inverter & UPSFeatures:
1. Pure Sine Wave Out put
2. DSP Technology
3. LCD Display
4. Compact Design
Control switches:1. Inverter/ UPS switch
a. Inverter- Low voltage- 100V High Voltage- 270V AC
b. UPS-Low voltage- 170V High Voltage -270V AC
2. Charger Selection Switch
Mains charger OFF – Mains charger will be permanently OFF and Battery will charge only from solar
Mains/solar- In this mode both charger will work UP TO 27.6V, mains charger will turned OFF @ 27.6V automatically and only solar will work
UPTO 28.6V.
3.Auto/Manual Switch:
Auto- This solar Hybrid inverter can provide power to the connected load by utilizing the PV power, Utility (Mains) power and battery power. When PV energy is good it will charge the connected batteries , when battery voltage reaches @28.6V Relay will turn ON and this inverter will convert power to the connected loads from solar and Batteries. When PV and Battery power is not sufficient for connected loads ( It means less than 23V) this inverter will source from the utility (mains) at the same time . When PV energy is not sufficient and Utility (mains) is failed, The System selects the Battery as source.
Manual-This inverter will work when mains failed.
Indication & Readings:
1. Solar- It will glow when solar is connected .2.
2. Charger ON- It will glow when charging starts.
3. Relay ON- It will glow when relay is ON.
Available Capacity:
1.5KVA,2KVA, 3KVA, 4KVA, 5KVA @ 24V, 36V & 48V
Solar Hybrid Inverter & UPS� Features:
� 1. Pure Sine Wave Out put
� 2. DSP Technology
� 3. LCD Display
� 4. Compact Design
� Control switches:
� 1. Inverter/ UPS switch
� a. Inverter- Low voltage- 100V High Voltage- 270V AC
� b. UPS-Low voltage- 170V High Voltage -270V AC
� 2. Charger Selection Switch
� Mains charger OFF – Mains charger will be permanently OFF and Battery will charge
only from solar
� Mains/solar- In this mode both charger will work UP TO 27.6V, mains
charger will turned OFF @ 27.6V automatically and only solar will work
UPTO 28.6V.
� 3.Auto/Manual Switch:
� Auto- This solar Hybrid inverter can provide power to the connected load by utilizing the
PV power, Utility (Mains) power and battery power. When PV energy is good it will charge
the connected batteries , when battery voltage reaches @28.6V Relay will turn ON and this
inverter will convert power to the connected loads from solar and Batteries. When PV and
Battery power is not sufficient for connected loads ( It means less than 23V) this inverter will
source from the utility (mains) at the same time . When PV energy is not sufficient and
Utility (mains) is failed, The System selects the Battery as source.
� Manual-This inverter will work when mains failed.
� Indication :
� 1. Solar- It will glow when solar is connected .2.
� 2. Charger ON- It will glow when charging starts.
� 3. Relay ON- It will glow when relay is ON.
� Readings
� 1. Solar PV Voltage
� 2. Current drawing from Solar
� 3. Total Units generated from Solar
� Available Capacity:
� 1.5KVA,2KVA, 3KVA, 4KVA, 5KVA @ 24V, 36V & 48V
SOLAR PCUInbuilt 3 Phase interleaved boost charger
Solar Power Conditioning unit (PCU) is an integrated system consisting of a solar charge controller, inverter and a Grid charger. It provides the facility to charger the battery bank either through Solar or Grid.
The PCU continuously monitors the state of Battery Voltage, Solar Power output and the loads. Due to sustained usage of power, when the Battery voltage falls below a preset level, the PCU will automatically transfer the load to the Grid power and also charge.
Once the Batteries are charged to the preset level, the PCU cuts off the Grid Power from the system and will restore to feeding the loads from the battery bank & also restore to charging the battery from the Available Solar power. The PCU always gives preference to the Solar Power and will use Grid power only when the Solar Power/ Battery is insufficient to meet the load requirement.
SOLAR PCU
� Solar PCU� Power - 10KW
� Switching device - IGBT
� Battery - 250V
� Out put Voltage - 220VAC
� Output Hz - 50 Hz
� Solar Panel - 10KW
10KW/240V
SOLAR INTEGRATED SINEWAVE OFFGRID INVERTER
PRODUCT FEATURES
• DSP Based Fully Digital Design
• Programmable solar priority mode
• High frequency PWM inverter
• Sine wave output
• Active MPPT control system
• Multi-phase interleaved MPPT
• User friendly LCD +LED display
• Intelligent battery charge management
• Soft start facility
• Synchronous load transfer
TECHNICAL SPECIFICATIONS
POWER 10KW
BATTERY 240V DC
WORKING
MODE
Solar priority /Grid priority Configurable as per site requirements
SOLAR
Solar controller Multi-phase interleaved high frequency converter with active maximum power tracking
Switching device MOSFET
Switching frequency 60 KHz
Solar input voltage range (VOC) 220V-320 V DC
Maximum solar panel current ≤40A
Maximum battery charging current 25A 5A -40A Selectable.
MAINS
Input low voltage 130V 80V – 180V Selectable
Input high voltage 265V 250V – 280v Selectable
Input frequency range 47 Hz – 58Hz
Output voltage Same as input voltage and frequency
Maximum battery charging current 6 A 4 A – 12 A selectable
Short circuit / over load Input circuit breaker
INVERTER
Inverter MOSFET inverter with transformer isolation
Switching frequency 20 KHz
Output voltage 220v ± 3% 200v – 240v selectable
Output frequency 50.1 Hz ± 1% Crystal controlled
Output PF ≥ 0.8 PF
Distortion ≤5% on linear load
Peak efficiency ≥90 %
Overload 120 % for 10 sec,150% for 4 sec,200% for 2 sec.shut down after the specified delay
Overload warning ≥85% load 70% - 100% selectable
Short circuit Shut down
Auto restart 3 times for battery low,smart auto-restart for over load
PROTECTIONS Over load,short circuit battery over charge,battery deep discharge,over temperature
SWITCH ON ,OFF, SCROLL/PAUSE
COOLING Forced air cooling with over temperature trip
ALARM Buzzer during over load warning, battery low warning and trip
LED Main status,inverter status,battery charger and fault
LCD Parameters Input volt, Output volt, Battery volt, Load percentage battery charging
current, Solar panel current, total generated solar energy in KWh
General messages Inverter status
Warning messages Overload, battery low
Trip messages Overload, battery low, over temperature, critical hardware failure
OTHERS Ambient temperature 0 °c ~40° c
Ambient humidity 10% ~ 90% (Non condensed)
Mechanical dimension