Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using...

30
© 2016 Bentley Systems, Incorporated Upgrading to MicroStation CONNECT Edition Paul Cusack, Bentley Systems

Transcript of Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using...

Page 1: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

1 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated © 2016 Bentley Systems, Incorporated

Upgrading to MicroStation CONNECT EditionPaul Cusack, Bentley Systems

Page 2: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

2 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

Just the Basics …

• Configuration files are simple text files– Execution starts at mslocal.cfg– generated at install time – includes msdir.cfg, which identifies the MicroStation directory– Then includes msconfig.cfg which is the main show

• MSCONFIG.CFG– Completely reorganized, in-line documentation explains what it does– Don’t change it!

Page 3: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

3 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

Level Changes in the CONNECT Configuration

V8i:SystemApplicationSiteProjectUser

CONNECT:SystemApplicationOrganizationWorkSpaceWorkSetRoleUser

Page 4: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

4 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

Changes to the V8i WorkSpace• New Folder Structure, Levels, Variables and

Files• System is moved to Program Files and

becomes Default• Interfaces removed• Standards renamed to Organization and moved• Two new Levels added: WorkSpace and Role

Page 5: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

5 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

_USTN_CONFIGURATION

_USTN_WORKSPACESROOT

_USTN_WORKSPACEROOT

_USTN_WORKSPACESTANDARDS_USTN_WORKSETSROOT

_USTN_WORKSETROOT

_USTN_WORKSETSTANDARDS

_USTN_ORGANIZATION

Page 6: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

6 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

Page 7: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

7 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

Just the DGNLIBs

• Seed ModelsDesign ModelDrawing ModelSheet Model

• LevelsLevel DefinitionsLevel Filters

• AnnotationText StylesNotes StylesDimension StylesDetailing Symbol StylesTable SeedsReport DefinitionsLabel CellsText Favorites

• TemplatesElement TemplatesTerrain Models (included here)

• Named ExpressionsNamed Expressions

• RenderingRender SettingsLightingMaterialsEnvironmentsPopulate Contents Vehicle Library

• ViewingSaved ViewsDisplay StylesNamed BoundariesDrawing BoundariesDisplay StylesDisplay RulesDWG Wireframe Display

• User Interface Customizations

Ribbon WorkflowsTabs, Groups, etc.Quick Access ToolbarTools and Tool BoxesContext Menus (right-click)Popup MenusIconsScreen Menus

• Other SettingsCellsColor BooksPrint Styles and DefinitionsProject Explorer Link SetsStandards Checker SettingsMarkup SettingsStandards Checker Batch Processor JobsCustom Line Style DefinitionsMulti‐Line StylesPropertiesItem TypesLink Sets

Page 8: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

8 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

Migrating Personal Files

• Allows users local customization of several personal settings• C:\Users\FIRST.LASTNAME\AppData\Local\Benltey\MicroStation\X.x.x\prefs\• The important ones:

– Personal.dgnlib– Personal.ucf– Personal.upf

Page 9: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

9 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

Bentley LEARN content

• MicroStation CONNECT Edition Upgrade for CAD Managers

Page 10: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

10 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

OpenRoads Designer

Page 11: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

11 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

ANZ Design Configuration

• ANZ = Australia and New Zealand

• Developed in collaboration with representatives and early adopters from:– RMS– vicroads– MRWA– Beca– Arcadis– Bentley Systems

• Includes workspaces for:– RMS – vicroads– MRWA– NZ

Page 12: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

12 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

ANZ Design Configuration for Users

• Workspaces and Workset• Seed Files• Levels and level filters• Line Styles• Cells• Element Templates• Feature Definitions• Design Standards• Sight Distance• Template Library • Superelevation• Curve Widening• Civil Cells• Reports• Control Features (switch parametric

constraint)

• Aquaplaning reports• Graphical Filters• Subsurface utilities• Function Keys and GUI

Customisations (context menu)• Display styles• Text Styles, Text Favorites• Labels• Drawing Scales• Sheet Seeds• Plan, Profile and Cross Section

Annotation• Sheet Borders• Macros

Page 13: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

13 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

Where to get the ANZ Configuration?

Page 14: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

14 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

ANZ Design Configuration for Administrators

• ANZ Configuration Areas– ANZ Design– MyCompany Design– Workspaces – Worksets

• Deploying Configuration to Network– Copying to a server – Redirecting local machines to network

• Template Library (using and loading from workset)• Sheet Borders

Page 15: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

15 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

ANZ Configuration levels / areas

• ANZ Design– applies always when using RMS,vicroads or MRWA– most configuration exists here

• MyCompany Design– applies always when using RMS,vicroads or MRWA– Rename to your company name and include your

company standards– Edit WorkSpaceSetup.cfg to point to your company

name CFG• WorkSpaces

– RMS Design, Vicroads Design & MRWA Design– Road authority specific standards

• WorkSets– Create new for each new project– Can include project specific standards

Page 16: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

16 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

ProjectWise Managed Workspaces

Page 17: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

17 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

Deploying Configuration to Network

• Beware of potential network performance issues

• To setup Configuration Folders on network– Copy INSTALLED_PATH\Company to \\MyNetwork\MyConfig\– Copy INSTALLED_PATH\Organization-Civil to \\MyNetwork\MyConfig\– Copy INSTALLED_PATH\WorkSets to \\MyNetwork\MyConfig\– Copy INSTALLED_PATH\WorkSpaces to \\MyNetwork\MyConfig\

• To redirect Workset Folders to a different network folder– Edit INSTALLED_PATH\WorkspaceSetup.cfg and change the MY_WORKSET_LOCATION

variable. For example:• MY_WORKSET_LOCATION = //MyNetwork/MyProjectData/MyProjects/

– Move \\MyNetwork\MyConfig\WorkSets to \\MyNetwork\MyProjectData\– Rename \\MyNetwork\MyProjectData\WorkSets to \\MyNetwork\MyProjectData\MyProjects

Page 18: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

18 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

Deploying to Network

• To redirect local machine to network– Edit WorkSpaceSetup.cfg– Company folder

• MY_COMPANY_LOCATION = //MyNetwork/MyConfig/MyCompany/– Organization Civil folder

• MY_CIVIL_ORGANIZATION_ROOT = //MyNetwork/MyConfig/MyOrganization-Civil/– Workspaces folder

• MY_WORKSPACES_LOCATION = //MyNetwork/MyConfig/MyWorkSpaces/– WorkSets folder

• MY_WORKSET_LOCATION = //MyNetwork/MyConfig/MyWorkSets/

Page 19: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

19 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

OpenRoads Designer Workspace Setup Learning Path

• Detailed training on Bentley LEARN

• http://learn.bentley.com

Page 20: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

20 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

Understanding the ANZ Design Configuration – WorkspaceSetup.cfg

Page 21: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

21 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

ANZ Design.cfg

Page 22: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

22 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

MyCompany Design.cfg

Page 23: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

23 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

VicRoads Design.cfg

Page 24: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

24 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

_VicRoads Project Template.cfg

Page 25: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

25 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

Configuring MyCompany Standards

• Rename INSTALLED_PATH\Company\MyCompany Design to YourCompanyName.

• Rename INSTALLED_PATH\Company\MyCompany Design.cfg to YourCompanyName.cfg

• Edit INSTALLED_PATH\WorkSpaceSetup.cfg and change the CIVIL_MY_COMPANY_NAME variable to the new YourCompanyName folder name. For example:

• CIVIL_MY_COMPANY_NAME = YourCompanyName• Add DGNLIBs and other configuration to YourCompanyName

folders as desired.

Page 26: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

26 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

Creating your own feature definitions

• Create new DGNLIB• Create level• Create Element Template• Create Feature Symbology• Create Feature Definition• OPTIONAL – create annotation group• Add to MyCompany Design\Dgnlib\Feature Definitions• Try it out

Page 27: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

27 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

Explore the ANZ Design Configuration

• Workspaces and Workset• Seed Files• Levels and level filters• Line Styles• Cells• Element Templates• Feature Definitions• Design Standards• Sight Distance• Template Library • Superelevation• Curve Widening• Civil Cells• Reports• Control Features (switch parametric

constraint)

• Aquaplaning reports• Graphical Filters• Subsurface utilities• Function Keys and GUI

Customisations (context menu)• Display styles• Text Styles, Text Favorites• Labels• Drawing Scales• Sheet Seeds• Plan, Profile and Cross Section

Annotation• Sheet Borders• Macros

Page 28: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

28 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

Template Library

• Best to be located in project folders with workset standards• Can be named Templates.itl and will be automatically found

Page 29: Upgrading to MicroStation CONNECT Edition · • ANZ Design – applies always when using RMS,vicroads or MRWA – most configuration exists here • MyCompany Design – applies

29 | WWW.BENTLEY.COM | © 2016 Bentley Systems, Incorporated

Sheet Borders

• Project specific sheet borders can be placed in workset standards• Can be named A1_Border.dgn or A3_Border.dgn and will be