UPDATED CV 2015

12

Click here to load reader

Transcript of UPDATED CV 2015

Page 1: UPDATED CV 2015

JEFFREY D. AUSTRIA Balikbayan road, Bendana compound

Tanay, Rizal. PhilippinesMobile+639064182878/ +639428047067Email: [email protected]: jepgiejaelPosition Desired: NDT Inspector Level II RT,

RTFI, PT, MT, UT FLAW

PERSONAL DATA:

Age : 33 yrs. oldDate of Birth : March 31, 1981Place of Birth : Malaya, Pililla, RizalGender : MaleCivil Status : MarriedHeight : 5’3"Weight : 115 lbs.Religion : Christian Seaman book : C0037786 Passport no. : EB6152164Language/Dialect : English/TagalogSSS no. : 33-6974292-5Citizenship : FilipinoTIN : 305-035-847-000Philhealth : 01-050228132-7

EDUCATIONAL BACKGROUND:

College : Computer (Programming)AMA Computer Learning CenterPlaza Aldea, Tanay, RizalJune1998 – March 2000

Secondary : Malaya National High SchoolMalaya, Pililla, Rizal1994 – 1998

Elementary : San Ildefonso CollegeTanay,Rizal

1988-1999

Page 2: UPDATED CV 2015

EMPLOYMENT HISTORY:

Company : ASIA CORROSION SERVICES, INC.Position : NDT Technician Level IIIndustry : Oil and Gas Duration : Jan 20, 2014 – Up to present dateLocation : Marikina City, PhilippinesManager : Rolando R. Ortanez

PRIMARY FUNCTION:

REQUALIFICATION OF 6 X 120 USG PIG TANKS PULLED OUT FROM MALLBERRY SUITES ( ILIGAN CITY )

Ultrasonic THICKNESS Gauging of Shell and Head Plates including NozzlesDetailed Inspection report shall be submitted containing the CERTIFICATION, COMPUTATION, DRAWING, UTG RESULT, PHOTOS, VISUAL INSPECTION/RECOMMENDATION, TANK DATA and COVERING LETTER.

PETRONAS ENERGY INC. ( ILIGAN CITY )

Requalification of 1500mt Spherical LPG tank. Conducting Ultrasonic Thickness Gauging of Sphere Top Crown Shell, Shell Plate and Bottom Plate.

Visual Inspection is the next to perform, Visual Inspected every bolt in flange at the Top Crown of the Sphere and Bottom Plate including the weldment and Sphere Coating.Doing Inspection Report of Sphere Ultrasonic Thickness Gauging and Visual Inspection such as CERTIFICATION, COMPUTATION, DRAWING, UTG RESULT, PHOTOS, VISUAL INSPECTION/RECOMMENDATION, TANK DATA and COVERING LETTER.

BOARDWALK VENTURES INC.Conduct Radiography test at Spiral weld in pipe wich will use at Hydrothermal wich have a Outside Diameter of 97.7mm diameter and 75mm diameter. Including film processing, Film Interpretation and reporting for the result of Radiographic test.

Page 3: UPDATED CV 2015

POLE PIER (SUBIC PHIL.)Conduct Radiography test at 12ӯ pipe which is oil line. Including film processing, Film Interpretation and reporting for the result of Radiographic test.

SEM CALACA POWER PLANT UNIT 1 shutdown job Conducting UT Thickness Gauging in water wall and every panel coil tube inside the boiler.Conducting Radiographic Test (RT) in every coil tube that are replace including in pent house.

SLPGC 2x 150 MW CFB POWER PLANT PROJECT (PHASE 1)Client: D.M.C.I Conducting UT FLAW DETECTION at 2000mm Ø with the thickness of 16mm. including elbow and fittings at WATER CIRCUMFERENTIAL PIPE (WCP) and FABYARD and FLUE LINER (CW and LW) at CHIMNEY. Conducting Radiographic Test (RT) at boiler tubes including film interpretation and RT report.

Responsible for performing quality inspection using the various NDT methods as applicable ( RT, UT FLAW, penetrant & magnetic particle testing).Responsibilities include processing, inspecting, & evaluating surface & subsurface discontinuities and accepting, rejecting, or reworking hardware in accordance with customer specifications.

PRINCIPLE DUTIES & RESPONSIBILITIES Certificates products that is in conformance with customer specifications&

maintains traceability to such certification as is applicable. Creates NDT techniques Performs penetrant,x-ray, UT FLAW and magnetic particle inspection,vaccum test

& interprets results. Performs preventive maintenance and calibrations on NDT equipment. Operates vapor degreaser & performs the necessary process checks. Properly processes, sorts and verifies x-ray film Communicates closely with engineers on scarp, the works and process issues. Ensure paperwork is properly done Helps others area as needed.

Page 4: UPDATED CV 2015

EMPLOYMENT HISTORY:

Company : CIFRA INDUSTRIAL SERVICESPosition : NDT Technician Level IIIndustry : Oil and Gas Duration : 5 Sept.2013 - January 15,2014Location : Limay Bataan PhilippinesManager : CaridadDe Leon

PRIMARY FUNCTION:

PETRON (RMP-2) REFINERY MASTER PLAN 2 on going contruction under DAELIM PHIL.INC .maincontructor located at Limay Bataan Phil. Subcon by ARGUS NDT PWHT Services doing Line Check to Fabrication & site location to DEAH,SUNGDO,ILYANG & SEBO MEC.

Doing linecheck every afternoon in each fabrication & site location to the following client.

DEAH PHIL.SUNGDOILYANG SEBO MEC

Then conducting radiographic test in each joint with different pipe schedule that is listed in every request given by each client everytime I conducting linecheck .After performing radiography at nightshift I collect all the films that each RT crew and doing developing until morning as a DARKROOM TECHNICIAN.

Responsible for performing quality inspection using the various NDT methods as applicable ( x-ray, penetrant & magnetic particle testing).Responsibilities include processing, inspecting, & evaluating surface & subsurface discontinuities and accepting, rejecting, or reworking hardware in accordance with customer specifications.

Page 5: UPDATED CV 2015

PRINCIPLE DUTIES & RESPONSIBILITIES

Certificates products that is in conformance with customer specifications& maintains traceability to such certification as is applicable.

Creates NDT techniques Performs penetrant,x-ray and magnetic particle inspection & interprets results. Performs preventive maintenance and calibrations on NDT equipment. Operates vapor degreaser & performs the necessary process checks. Properly processes, sorts and verifies x-ray film Communicates closely with engineers on scarp, the works and process issues. Ensure paperwork is properly done Helps others area as needed.

Company : STORK COOPERHEAT SAUDI ARABIA Co.Ltd.Position : NDT Technician Level IIIndustry : Oil and Gas Duration : 10 July 2008- 25 November 2011Location : Jubail City Kingdom of Saudi ArabiaManager : AshokanNelekandan

PRIMARY FUNCTION:

SHOIBA ( SAUDI ELECTRIC)Conduct Radiography of different types of Fittings and Pipings and its Diameter such as 4ӯ, up to 30ӯ. Including Film Processing, Evaluation of Films and Reporting

QURAYYAH (SAUDI ELECTRIC)Conduct Conventional Radiography (IRIDIUM 192) of different types of Fittings and Pipings and its Diameter, Including Film Processing, Evaluation of Films and Reporting

Page 6: UPDATED CV 2015

Conducting Radiography using SAFERAD a Radiography using SELINIUM 75

The radiation controlled area barriers can be set at less than 1 metre away from the radioactive source, even with source activities in excess of 80 Curies. Because radiography can be carried out without interfering with other operations it means that schedules can be maintained or improved and therefore huge savings can be made. The SAFER (Small Area For Exposure Radiography) radiography method has many potential benefits when compared to traditional radiography methods.

Conducting Radiographic using SAFERAD in diffrent pipe diameter including Film Processing, Interpretation and reporting.

Responsible for performing quality inspection using the various NDT methods as applicable ( x-ray, penetrant & magnetic particle testing).Responsibilities include processing, inspecting, & evaluating surface & subsurface discontinuities and accepting, rejecting, or reworking hardware in accordance with customer specifications.

AL-RASHID (ARCC) SHARQ PROJECTConducting Radiography using SAFERAD a Radiography using SELINIUM 75

The radiation controlled area barriers can be set at less than 1 metre away from the radioactive source, even with source activities in excess of 80 Curies. Because radiography can be carried out without interfering with other operations it means that schedules can be maintained or improved and therefore huge savings can be made. The SAFER (Small Area For Exposure Radiography) radiography method has many potential benefits when compared to traditional radiography methods.

Conducting Radiographic using SAFERAD in diffrent pipe diameter including Film Processing, Interpretation and reporting.

Page 7: UPDATED CV 2015

PRINCIPLE DUTIES & RESPONSIBILITIES

Creates NDT techniques Performs penetrant,x-ray and magnetic particle inspection & interprets results. Performs preventive maintenance and calibrations on NDT equipment. Operates vapor degreaser & performs the necessary process checks. Properly processes, sorts and verifies x-ray film Communicates closely with engineers on scarp, the works and process issues. Ensure paperwork is properly done Helps others area as needed.

EMPLOYMENT HISTORY:

Company : Al MutawaSamyong NDT Co., LTD (AMSYCO)Position : NDT Technician Level IIIndustry : Oil and Gas Duration : 30 March 2007 - 28 May 2008Location : Jubail City Kingdom of Saudi ArabiaManager : AshokanNelekandan

PRIMARY FUNCTION:

Responsible for performing quality inspection using the various NDT methods as applicable ( x-ray, penetrant & magnetic particle testing).Responsibilities include processing, inspecting, & evaluating surface & subsurface discontinuities and accepting, rejecting, or reworking hardware in accordance with customer specifications.

Page 8: UPDATED CV 2015

PRINCIPLE DUTIES & RESPONSIBILITIES

Certificates products that is in conformance with customer specifications& maintains traceability to such certification as is applicable.

Creates NDT techniques Performs penetrant,x-ray and magnetic particle inspection & interprets results. Performs preventive maintenance and calibrations on NDT equipment. Operates vapor degreaser & performs the necessary process checks. Properly processes, sorts and verifies x-ray film Communicates closely with engineers on scarp, the works and process issues. Maintain lot integrity Ensure paperwork is properly done Helps others area as needed.

EMPLOYMENT HISTORY:

Company : CIFRA INDUSTRIAL SERVICESPosition : NDT Technician Level IIIndustry : Oil and GasDuration : 3 Sept.2006 - March 3 2007Location : Gen. Mojica St. Makati CityManager : De Leon

Job Description RT Technician Level II Film Developer/Film Interpreter Conducting R.T. of F2301, of F2302, F2303 Pipeline, of 4”Ø to 6”

to Furnace pipe interpret of radiographic film and inspection jo, for Petron Co. AlanganLimay, Bataan.Ultrasonic Gauging (UTG) testing of Pipe and plates thickness for metric Developing Film, film drying, arranging films, interprets film, do tracing loading film into lead screen then to film jacket. R.T. and interpret convection tubes (Studded)) 6ӯ double wall single image (contact) R.T. and interpret radiant tubes (Studded) H-PIN, HOOP and Rise) 3ӯ, 4ӯ, 6ӯ, 18ӯ pipelines R.T. of 2ӯ schedule 80 double wall, double image elliptical stainless steel, Magnetic Particle Inspection (M.P.I.) of seam weld of spherical tank using cleaner remover magnetic, 7H-F magnetic particles using magnetic yolk permanent magnetic Penetrant Test (P.T.) O.D 14ӯ H-pin and white contrast paint.

Holiday Test (High voltage porosity detector) of oil transfer line.

Page 9: UPDATED CV 2015

Tools and Equipment Use

1. Iridium 1922. Selenium 75 (Saferad)3. Magnetic Yolk4. Cleaner Remover 5. Penetrant 6. Developer 7. Olympus EPOCH LT8. Agfa Film Viewer9. Densitometer10. TLD 11. Dose Guard

TRAINING AND SEMINARS ATTENDED:

1. On the job Training on PT,RT,UT,MTCIFRA INDUSTRIAL SERVICES.Makati City, Philippines

2. H2S/B.A. TRAINING COURSEPilipinas Shell Petroleum Corporation (Tabangao Refinery)

3. Passed, Radiation Safety Examination conducted by Saudi ARAMCO.August 20, 2007

4. In House training and certification program RT and MTCertified ASNT Level II on RT and MT.AMSYCO NDT Co. Ltd.August 30, 2007

5. Received training and instruction in the use of the SAFERAD RADIOGRAPHY SYSTEM. (Reference MAP-17,001 Rev 05: Personnel Training Manual)

6. GLOBAL TRAINING SYSTEM: BASIC SAFETY TRAINING (SOLAS) MARCH 11-19, 2013

I hereby certify that the above information is true and correct to the best of my knowledge and belief.

Page 10: UPDATED CV 2015