Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units...

28
1 / 24 JOULE - manufacturing excellence Unvented and Vented Stainless Steel Hot Water Cylinders IE edition www.joule.ie

Transcript of Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units...

Page 1: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

1 / 24

JOULE - manufacturing excellence

Unvented and Vented Stainless Steel Hot Water Cylinders IE ed

ition

www.joule.ie

Page 2: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

Joule was formed in 2008 to offer the heating, plumbing and hardware merchant network a ser-vice that was based on product expertise and knowledge, large stock holding, short delivery times and a nationwide distribution network. The strength of this offering can be seen in the quality and innovation of our product range in renewa-bles, hot water production & storage. From humble beginnings Joule rapidly grew to become Ireland’s premier supplier of solar thermal and hot water storage solutions. In 2010 Joule opened its fast manufacturing facil-ity in Dublin. This facility had an output capacity of 24,000 units per annum working on a single shift per day. Along with the manufacturing, Joule also opened Irelands most advanced solar thermal training centre. Joule believe that we must work with all stakeholders in providing the customer an outstanding service and investing in training for installers is just another small example of this philosophy.

In 2011 Joule opened its first distribution centre in Cheshire, UK. The UK arm of the Joule Group is rapidly expanding. With Joule’s innovative product range and drive for excellence in customer service, demand is quickly growing through our Cheshire distribution centre. Joule UK is continuing to offer customers excellence in product & service and the result of this will help Joule UK to become one of the UK’s favourite Solar Thermal & Hot Water Storage suppliers. Joule Poland is the Joule Group’s latest develop-ment. Demand for high quality stainless steel hot water storage cylinders is rising across Europe and particularly in Poland. Joule’s product range is proving very popular and to meet this demand the Joule Group has recently opened a distribution centre in Poland. This demand is a testament to Joule’s quality in both product and service.

UK IE PL WORLDWIDE WORLDWIDE

Who are we?

NSAI Agrément

All white version also available: NSAI_Agrement_Wht

NSAI_Agrement_2Col

NSAI_Agrement_Rev

NSAI_Agrement_1Col

NSAI_Agrement_Blk

NSAI Certification

All white version also available: NSAI_Certification_Wht

NSAI_Certification_2Col

NSAI_Certification_Rev

NSAI_Certification_1Col

NSAI_Certification_Blk

Page 3: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

3 / 24

JOULE - manufacturing excellence

Domestic Selection Sizing GuideThese recommendations are based on the guide-lines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc.

Hot Water Demand Bedrooms Gas / Oil Indirect Units

Electric Indirect Units

1 Standard Bath or Shower

Bedsit / 1 Bed 150 150

2-3 Bed 150 200

3-4 Bed 150 200

1 Standard Bath 2-3 Bed 150 200

3-4 Bed 150 200

1 Bath & En-Suite 2-3 Bed 150 200

3-4 Bed 150 200

4-5 Bed 200 200

2 Standard Baths 2-3 Bed 200 200

3-4 Bed 200 200

4-5 Bed 200 250

3 Standard Baths 3-4 Bed 250 300

4-5 Bed 250 300

5-6 Bed 300 300

Commercial Selection Sizing GuideThese recommendations are based on the guide-lines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc.

Typical Commercial Application Indirect Units

Large House 6 Bed / 4 Bathrooms 400

Guest House 8 Bed / 4 Bathrooms 2 x 300

Small Hotel 8 Bed / 8 Bathrooms 3 x 200

Sports Pavilion 25 People / 4 Showers 2 x 300

Sports Pavilion 25 People / 6 Showers 3 x 200

Students House 25 People / 3 Bathrooms 3 x 300

Old People’s Home 60 People / 10 Showers 5 x 300 (each supplying 2 bathrooms)

Selecting the correct size of cylinder requires con-sideration of a nuber of variables, including the volume of water needed, the energy source and the space available. Calculating the colume needed can be achieved by adding together the individual volumes of each appliance that uses hot water and how frequently it is used. The energy source is the next variable to consider, as it will have a direct impact on the cylinder size.

CycloneResponding rapidly to changing market expecta-tions we have evolved the Joule Cyclone vented and unvented stainless steel cylinders. All our Cylinders are formed from stainless steel, con-tinuing our phylosophy of only using the finest materials. We are so confident in our construction that we offer a 25 year limited guarantee* on most of the Cyclone range. To keep a breast with devel-opments the Joule Cyclone range has many key advantages.

Butt WeldingAll Cyclone cylinders are butt seam welded, this gives greater rigidity and removes the threat of crevice corrosion associated with some cylinders.

Flexible ConnectionsJoule recognise that sometimes the need for 1” hot & cold connections with adaptable 3/4” fitting is a key way forward for the installer.

Sensor PocketsKey to ensuring the cylinder works and performs to its optimal ability is the sensor pockets, these determine how the unit calls for heat from the external source. The Cyclone has 10mm solar sen-sor pockets ensuring the probets from the solar fit correctly and effectively, we also ensured the aquastat pocket is produce to flair out holding the stat firmly in place

CoilsWith the continued introduction of heat sources Joule has looked closely at the best possible option for coils within the Cyclone Range, we use both conventional rigid plain tube and CSST high effiency coil to ensure all our units perform to the highest possible standards, this flexibility ensures Joule can produce any heat surface area required.

Key advantages 3 / 28

JOULE IRELANDT +353 1 6237080 F +353 1 6269337 E [email protected] W www.joule.ie

Page 4: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

Joule high grade Quick Recovery vented cylinders

• 1/2 hour recovery• 1” Gravity Coils as standard• 1” Hot & Cold Connection• Dual Element immersion fitted• Standard BSP Connection All Round• Shower Connection• Equivalent to Grade I Copper• Manufactured from stainless steel• All joints are welded• Connection locations same as Copper equivalent,

so easy change over

Quick Recoveryquick recovery high grade half the price

The future of

vented hot

water storage

come complete with

dual element

incloy full sizeimmersions

come complete with

shower connec-tion

1” Adaptable Hot Water Draw

1” Boiler Flow

1” Boiler Return

Immersion Heater

1” Adaptable Cold Water Inlet

Page 5: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

5 / 24

JOULE - manufacturing excellence

Technical Information 5 / 28

JOULE IRELANDT +353 1 6237080 F +353 1 6269337 E [email protected] W www.joule.ie

0 0 0 1 00 0 00Temperature and Pressure Relief Valve

Expansion Vessel

Dual ThermostatHigh Flow RateInlet Control Set

Incoloy Long 240V 3kW Immersion Heater

15/22 Tundish 22mm Thermostatic Mixing Valve

Expansion Vessel Hose

22 mm 2 Port Motorzed Diverting Valve

DIRECT, INDIRECT, DIRECT-INDIRECT, TWIN COIL, TRIPLE COIL

Model 30x18 36x18 36x16 42x18 42x16 48x18 48x16 54x18 54x16 60x18 60x16

Nominal Height (mm) 750 900 900 1050 1050 1200 1200 1350 1350 1800 1800

Nominal Diameter (mm) 450 450 400 450 400 450 400 450 400 450 400

Capacity (litre)

Immersion 24 24 24 36 36 36 36 36 36 36 36

Reheat time (min) 30 30 30 30 30 30 30 30 30 30 30

All units come insulated as standard. Special and Plain cylinders available on request.

1” Adaptable Hot Water Draw

1” Boiler Flow

1” Boiler Return

Immersion Heater

1” Adaptable Cold Water Inlet

Page 6: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

Tank in Tank EcoThe fastest recovery hot water cylinder available

• 20 min recovery of Domestic Hot Water• Suitable for Heat Pumps because of large

Surface Area• Suitable for Solar Thermal• Suitable for pellet or log burners• Design reduces boiler cycling & improves

boiler efficiency• Most advanced Domestic Hot Water storage

cylinder available• Tank design reduces limescale buildup

Eco80With the requirement for more energy efficient solu-tions, Joule offer the full Cyclone range with Eco80 specification. The eco 80 range increasea insula-tion thickness to 80mm nominal.

NoteInner tank must be filled before outer tank.

Tank in Tank Ecofast recovery tank-in-tank cylinder - perfect partner to condensing boiler

3/4” Solar Return

DHW Tank

1” Connection

T/P Relief ValveCold Water SupplyHor Water SupplySecondary Return

3/4” Solar Flow

1” Connection

1” Connection

1” Connection

1” Connection1” Connection

1” Connection

1” Connection

Page 7: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

7 / 24

JOULE - manufacturing excellence

1 1 1 1 11 1 10Temperature and Pressure Relief Valve

Expansion Vessel

Dual ThermostatHigh Flow RateInlet Control Set

Incoloy Long 240V 3kW Immersion Heater

15/22 Tundish 22mm Thermostatic Mixing Valve

Expansion Vessel Hose

22 mm 2 Port Motorzed Diverting Valve

Technical Information 7 / 28

JOULE IRELANDT +353 1 6237080 F +353 1 6269337 E [email protected] W www.joule.ie

STANDARD

Volume (l) 150 200 250 300 400 500

Height (mm) 1085 1085 1335 1535 1535 1880

Diameter (mm) 500 560 560 560 660 660

Weight Empty (kg) 30 34 43 47 62 75

Weight Full (kg) 180 234 293 347 462 575

Reheat Indirect Total Minutes 21 26 26 32 35 35

Reheat 3 kW Immersion Total Min. 63 91 118 141 175 222

Dedicated Solar Volume - - - - - -

Standard Standing Loss kWh/Day 1.45 1.84 2.19 2.32 2.45 2.58

Eco80 Standing Loss kWh/Day 1.39 1.63 1.73 1.95 2.19 2.29

Litres in first 30 min 40 °C 320 321 418 558 686 922

Litres in first 30 min 45 °C 263 275 348 464 582 790

Litres in first 30 min 60 °C 175 161 206 274 358 504

Litres in first hour 40 °C 938 1063 1225 1633 1872 2666

Litres in first hour 45 °C 751 911 1003 1338 1559 2285

Litres in first hour 60 °C 426 536 590 786 935 1368

Continuous Flow (l/h) 827 890 967 1289 1423 2093

Continuous Flow (l/h) 673 763 786 1048 1172 1794

Continuous Flow (l/h) 378 450 461 614 693 1037

Absorbed Power (kW) 29 31 32 43 48 73

Page 8: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

The Joule Copper and Stainless Steel Thermal Stores are the next generation of heating and hot water pro-duction. The Joule thermal store has been designed with multi fuel heating systems in mind. The cylin-der allows an easy installation of solid fuel, solar and boiler easily and effectively. The thermal store allows pressurised hot water heated from solid fuel safely and fully compliant with current plumbing practices and standards. The tank operates like a hot water cyl-inder in reverse. The tank is completely full of heating system water, the domestic hot water flows through a network of coils up through the centre of the tank sup-plying you with high flow rate pressurised hot water at piping hot temperatures. The thermal store is ideally suited to providing solar heat support and domestic hot water production simultaneously and easily.

Copper or Stainless Steel?

When choosing your Joule Thermal Store it is im-portant to consider what pressure the heating sys-tem will be operating at. Our Stainless Steel thermal stores are better suited to high pressure heating systems because of their higher tensile strength. Our Copper thermal store is a better choice for ar-eas of hard water. While Joule always require hard water to be treated so that is maintained below 200ppm Total Hardness in water conditions where the untreated levels are higher than this figure the Joule Copper Thermal Store is recommended.

Thermal Storeincorporating mains pressure (boosted) domestic hot water

1” Connection

1” Connection

1” Connection

1” Connection

Solar 3/4” Return

Solar 3/4” Flow

Link 1”

Aquastat Pocket

1” Connection

Aquastat Pocket

Immersion Heater

Link 1”

Aquastat Pocket

1” Connection

Solar Sensor

DHW 1” Flow

1” Connection

1” Connection

Aquastat Pocket

Hot Water Draw

Page 9: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

9 / 24

JOULE - manufacturing excellence

0 1 1 1 00 0 01Temperature and Pressure Relief Valve

Expansion Vessel

Dual ThermostatHigh Flow RateInlet Control Set

Incoloy Long 240V 3kW Immersion Heater

15/22 Tundish 22mm Thermostatic Mixing Valve

Expansion Vessel Hose

22 mm 2 Port Motorzed Diverting Valve

STAINLESS STEEL COPPER

Volume (l) 200 250 300 400 500 200 250 300

Height (mm) 1400 1335 1535 1535 1880 1400 1600 1800

Diameter (mm) 500 560 560 660 660 450 450 500

Weight Empty (kg) 44 53 57 72 85 32 41 47

Weight Full (kg) 244 303 357 472 585 232 241 247

1st Hour Hot Water (l/h) @50 Deg C 150 187.5 225 300 375 150 187.5 225

Max Flow Rate (l/min) @50 Deg C 15 17 20 22 24 15 17 20

kW Load 1 Hour Recovery 13 16 19 26 32 13 16 19

Dedicated Solar Volume (l) 110 135 160 210 260 110 135 160

Standing Loss Cylinder (kWh/Day) 1.7 1.9 2.0 2.41 2.54 1.7 2.0 2.1

Technical Information 9 / 28

JOULE IRELANDT +353 1 6237080 F +353 1 6269337 E [email protected] W www.joule.ie

Hot Water Draw

Page 10: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

Cyclone Direct These cylinders are designed to work with elec-tricity only. The water is heated using electrical elements and they do not have any ability to heated by oil or gas boilers.

Immersion Heater optionsIncoloy immersions come as standard in all Joule Cyclone Cylinders unless otherwise stated. Incoloy immersions are designed for low to medium use in a domestic application. If the water been stored is hard or the usage is high, Joule recommend Titanum Immersions.

Eco80With the requirement for more energy efficient solu-tions, Joule offer the full Cyclone range with Eco80 specification. The eco 80 range increasea insula-tion thickness to 80mm nominal.

Directefficient electrically heated hot water

3/4” Secondary Return

Immersion Heater1” Adaptable Cold Water Inlet

1/2” T&P Relief Valve (fitted)

1” Adaptable Hot Water Draw

Immersion Heater

Page 11: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

11 / 24

JOULE - manufacturing excellence

STANDARD SLIM LINE SPECIAL

Volume (l) 125 150 170 200 250 300 400 500 100 120 135 150 175 205 230 166 193 222 223 225 270 280 300 305 342 360

Height (mm) 925 1085 1205 1085 1335 1535 1535 1880 925 1085 1205 1335 1535 1880 2000 925 1335 1535 925 1205 1085 1880 2000 1205 1335 1880

Diameter (mm) 500 500 500 560 560 560 660 660 440 440 440 440 440 440 440 560 500 500 660 560 660 500 500 660 660 560

Weight Empty (kg) 26 30 32 34 43 47 62 75 20 24 28 30 34 36 40 32 34 38 39 40 45 46 47 48 55 58

Weight Full (kg) 151 180 202 234 293 347 462 575 120 144 163 180 209 241 270 198 227 260 262 265 315 326 347 353 397 418

Reheat Indirect Total Minutes - - - - - - - - - - - - - - - - - - - - - - - - - -

Reheat 3 kW Immersion Total Min. 48 63 75 91 118 141 175 222 44 47 59 63 76 93 112 72 87 101 102 110 135 138 141 144 152 165

EN12897 Heat Exchange kW - - - - - - - - - - - - - - - - - - - - - - - - - -

Dedicated Solar Volume - - - - - - - - - - - - - - - - - - - - - - - - - -

Standard Standing Loss kWh/Day 1.23 1.41 1.53 1.8 2.15 2.28 2.41 2.54 1.18 1.25 1.38 1.41 1.55 1.82 1.92 1.48 1.75 1.86 1.87 1.9 2.2 2.24 2.28 2.3 2.35 2.38

Eco80 Standing Loss kWh/Day 1.16 1.36 1.44 1.69 1.91 2.15 2.25 1.03 1.12 1.17 1.31 1.36 1.46 1.64 1.43 1.40 1.62 1.63 1.66 1.71 1.72 1.91 1.94 2.10 2.12 2.16

1 1 1 2 11 1 00Temperature and Pressure Relief Valve

Expansion Vessel

Dual ThermostatHigh Flow RateInlet Control Set

Incoloy Long 240V 3kW Immersion Heater

15/22 Tundish 22mm Thermostatic Mixing Valve

Expansion Vessel Hose

22 mm 2 Port Motorzed Diverting Valve

Technical Information 11 / 28

JOULE IRELANDT +353 1 6237080 F +353 1 6269337 E [email protected] W www.joule.ie

9 kW Titanium Immersion

• High Use• Quicker Recovery• Hard Water

3 kW Titanium Immersion

• High Use• Hard Water

6 kW Titanium Immersion

• High Use• Quick Recovery• Hard Water

9 kW Incoloy Immersion

• Intermittent Use• Quicker Recovery• Soft Water

3 kW Incoloy Immersion

• Intermittent Use• Soft Water

6 kW Incoloy Immersion

• Intermittent Use• Quick Recovery• Soft Water

When using Eco80, dimensions will change to allow for extra insulation.

Page 12: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

Direct SolarThese cylinders are designed to have their primary heat source coming from electrical Elements with a secondary Solar Coil for solar support. These cylin-ders cannot be heated by an oil or gas boiler.

Immersion Heater optionsIncoloy immersions come as standard in all Joule Cyclone Cylinders unless otherwise stated. Incoloy immersions are designed for low to medium use in a domestic application. If the water been stored is hard or the usage is high, Joule recommend Titanum Immersions.

Eco80With the requirement for more energy efficient solu-tions, Joule offer the full Cyclone range with Eco80 specification. The eco 80 range increasea insula-tion thickness to 80mm nominal.

Direct Solarsolar supported efficient electrically heated hot water

3/4” Secondary Return

Immersion Heater

1” Adaptable Cold Water Inlet

1/2” T&P Relief Valve (fitted)

1” Adaptable Hot Water Draw

Immersion Heater

Plain Aquastat Pocket

Solar Sensor

Solar 3/4” Return

Solar 3/4” Flow

Solar Sensor

Page 13: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

13 / 24

JOULE - manufacturing excellence

Technical Information

1 1 1 2 11 1 00Temperature and Pressure Relief Valve

Expansion Vessel

Dual ThermostatHigh Flow RateInlet Control Set

Incoloy Long 240V 3kW Immersion Heater

15/22 Tundish 22mm Thermostatic Mixing Valve

Expansion Vessel Hose

22 mm 2 Port Motorzed Diverting Valve

13 / 28

STANDARD SLIM LINE SPECIAL

Volume (l) 150 170 200 250 300 400 500 100 120 135 150 175 205 230 166 193 222 223 225 270 280 300 305 342 360

Height (mm) 1085 1205 1085 1335 1535 1535 1880 925 1085 1205 1335 1535 1880 2000 925 1335 1535 925 1205 1085 1880 2000 1205 1335 1880

Diameter (mm) 500 500 560 560 560 660 660 440 440 440 440 440 440 440 560 500 500 660 560 660 500 500 660 660 560

Weight Empty (kg) 30 32 34 43 47 62 75 20 24 28 30 34 36 40 32 34 38 39 40 45 46 47 48 55 58

Weight Full (kg) 180 202 234 293 347 462 575 120 144 163 180 209 241 270 198 227 260 262 265 315 326 347 353 397 418

Reheat Indirect Total Minutes - - - - - - - - - - - - - - - - - - - - - - - - -

Reheat 3 kW Immersion Total Min. 63 75 91 118 141 175 222 44 47 59 63 76 93 112 72 87 101 102 110 135 138 141 144 152 165

EN12897 Heat Exchange kW - - - - - - - - - - - - - - - - - - - - - - - - -

EN12897 Solar Heat Exchange kW 16 16 16 18 18 22 22 16 16 16 16 16 16 18 16 16 16 16 16 18 18 18 18 18 22

Dedicated Solar Volume 85 95 110 135 160 210 260 60 70 78 85 98 113 125 93 107 121 122 123 145 150 160 163 181 190

Standard Standing Loss kWh/Day 1.41 1.53 1.8 2.15 2.28 2.41 2.54 1.18 1.25 1.38 1.41 1.55 1.82 1.92 1.48 1.75 1.86 1.87 1.9 2.2 2.24 2.28 2.3 2.35 2.38

Eco80 Standing Loss kWh/Day 1.36 1.45 1.59 1.69 1.91 2.15 2.25 1.03 1.12 1.32 1.35 1.46 1.61 1.64 1.40 1.56 1.62 1.63 1.66 1.71 1.72 1.91 1.94 2.10 2.12

JOULE IRELANDT +353 1 6237080 F +353 1 6269337 E [email protected] W www.joule.ie

When using Eco80, dimensions will change to allow for extra insulation.

Page 14: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

IndirectThese cylinders are designed to be heated indrect-ly using of an oil or gas boiler. They come complete with one electric Element to intermittently support the water heating system.

mmersion Heater optionsIncoloy immersions come as standard in all Joule Cyclone Cylinders unless otherwise stated. Incoloy immersions are designed for low to medium use in a domestic application. If the water been stored is hard or the usage is high, Joule recommend Titanum Immersions.

Eco80With the requirement for more energy efficient solu-tions, Joule offer the full Cyclone range with Eco80 specification. The eco 80 range increasea insula-tion thickness to 80mm nominal.

Indirectefficient indirectly heated hot water

3/4” Secondary Return

Immersion Heater

3/4” Boiler Return

Plain Aquastat Pocket

3/4” Boiler Return

1” Adaptable Cold Water Inlet

1/2” T&P Relief Valve (fitted)

1” Adaptable Hot Water Draw

Page 15: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

15 / 24

JOULE - manufacturing excellence

1 1 1 1 11 1 10Temperature and Pressure Relief Valve

Expansion Vessel

Dual ThermostatHigh Flow RateInlet Control Set

Incoloy Long 240V 3kW Immersion Heater

15/22 Tundish 22mm Thermostatic Mixing Valve

Expansion Vessel Hose

22 mm 2 Port Motorzed Diverting Valve

STANDARD SLIM LINE SPECIAL

Volume (l) 125 150 170 200 250 300 400 500 100 120 135 150 175 205 230 166 193 222 223 225 270 280 300 305 342 360

Height (mm) 925 1085 1205 1085 1335 1535 1535 1880 925 1085 1205 1335 1535 1880 2000 925 1335 1535 925 1205 1085 1880 2000 1205 1335 1880

Diameter (mm) 500 500 500 560 560 560 660 660 440 440 440 440 440 440 440 560 500 500 660 560 660 500 500 660 660 560

Weight Empty (kg) 26 30 32 34 43 47 62 75 20 24 28 30 34 36 40 32 34 38 39 40 45 46 47 48 55 58

Weight Full (kg) 151 180 202 234 293 347 462 575 120 144 163 180 209 241 270 198 227 260 262 265 315 326 347 353 397 418

Reheat Indirect Total Minutes 19 21 24 26 26 32 35 35 15 19 21 23 27 28 32 26 26 30 31 31 30 31 34 34 30 32

Reheat 3 kW Immersion Total Min. 48 63 75 91 118 141 175 222 44 47 59 63 76 93 112 72 87 101 102 110 135 138 141 144 152 165

EN12897 Prim. Heat Exchng (kW) 16 16 16 18 22 22 28 35 16 16 16 16 16 18 18 16 18 18 18 18 22 22 22 22 28 28

EN12897 Solar Heat Exchng (kW) - - - - - - - - - - - - - - - - - - - - - - - - - -

Dedicated Solar Volume - - - - - - - - - - - - - - - - - - - - - - - - - -

Standard Standing Loss kWh/Day 1.23 1.41 1.53 1.8 2.15 2.28 2.41 2.54 1.18 1.25 1.38 1.41 1.55 1.82 1.92 1.48 1.75 1.86 1.87 1.9 2.2 2.24 2.28 2.3 2.35 2.38

Eco80 Standing Loss kWh/Day 1.05 1.35 1.45 1.59 1.69 1.91 2.15 2.25 1.03 1.12 1.32 1.35 1.46 1.61 1.64 1.43 1.56 1.62 1.63 1.66 1.71 1.72 1.73 1.94 2.10 2.12

Technical Information 15 / 28

JOULE IRELANDT +353 1 6237080 F +353 1 6269337 E [email protected] W www.joule.ie

When using Eco80, dimensions will change to allow for extra insulation.

Page 16: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

Twin Coilefficient solar supported indirectly heated hot water

Twin CoilThese cylinders are designed to be heated indrect-ly using of an oil or gas boiler. They come complete with one electric Element to intermittently support the water heating system.

Immersion Heater optionsIncoloy immersions come as standard in all Joule Cyclone Cylinders unless otherwise stated. Incoloy immersions are designed for low to medium use in a domestic application. If the water been stored is hard or the usage is high, Joule recommend Titanum Immersions.

Eco80With the requirement for more energy efficient solu-tions, Joule offer the full Cyclone range with Eco80 specification. The eco 80 range increasea insula-tion thickness to 80mm nominal.

3/4” Boiler Flow

3/4” Secondary Return

1” Adaptable Cold Water Inlet

3/4” Boiler Return

3/4” Solar Flow

1/2” T&P Relief Valve (fitted)

Plain Aquastat Pocket

Plain Aquastat Pocket

Plain Solar Sensor

3/4” Solar Return

Plain Solar Sensor

1” Adaptable Hot Water Draw

Immersion Heater

Page 17: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

17 / 24

JOULE - manufacturing excellence

STANDARD SLIM LINE SPECIAL

Volume (l) 170 200 250 300 400 500 175 205 230 193 222 225 270 280 300 305 342 360

Height (mm) 1205 1085 1335 1535 1535 1880 1535 1880 2000 1335 1535 1205 1085 1880 2000 1205 1335 1880

Diameter (mm) 500 560 560 560 660 660 440 440 440 500 500 560 660 500 500 660 660 560

Weight Empty (kg) 32 34 43 47 62 75 34 36 40 34 38 40 45 46 47 48 55 58

Weight Full (kg) 202 234 293 347 462 575 209 241 270 227 260 265 315 326 347 353 397 418

Reheat Indirect Total Minutes 24 26 26 32 35 35 27 28 32 26 30 31 30 31 34 34 30 32

Reheat 3 kW Immersion Total Min. 75 91 118 141 175 222 76 93 112 87 101 110 135 138 141 144 152 165

EN12897 Prim. Heat Exchng (kW) 16 18 22 22 28 35 16 18 18 18 18 18 22 22 22 22 28 28

EN12897 Solar Heat Exchng (kW) 16 16 18 18 22 22 16 16 18 16 18 18 18 18 18 18 22 22

Dedicated Solar Volume 95 110 135 160 210 260 98 113 125 107 121 123 145 150 160 163 181 190

Standard Standing Loss kWh/Day 1.53 1.8 2.15 2.28 2.41 2.54 1.55 1.82 1.92 1.75 1.86 1.9 2.2 2.24 2.28 2.3 2.35 2.38

Eco80 Standing Loss kWh/Day 1.45 1.59 1.69 1.91 2.15 2.25 1.46 1.61 1.64 1.56 1.62 1.66 1.71 1.72 1.91 1.92 2.10 2.12

1 1 1 1 11 1 10Temperature and Pressure Relief Valve

Expansion Vessel

Dual ThermostatHigh Flow RateInlet Control Set

Incoloy Long 240V 3kW Immersion Heater

15/22 Tundish 22mm Thermostatic Mixing Valve

Expansion Vessel Hose

22 mm 2 Port Motorzed Diverting Valve

Technical Information 17 / 28

JOULE IRELANDT +353 1 6237080 F +353 1 6269337 E [email protected] W www.joule.ie

When using Eco80, dimensions will change to allow for extra insulation.

Page 18: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

Joule Cyclone triple coil cylinders have been designed specifically with multi fuel applications in mind. Featuring a purpose designed solar coil, which allows maximum heat transfer of solar energy into the stored water and a 28mm (1”) gravity coil which facilitates the use of gravity fed solid fuel systems. The cylinders are suitable for use with a wide range of solar systems now available and are an efficient and environmentally friendly way of providing domestic hot water. Combine this with the use of excess heat from your solid fuel system during winter, this cylinder allows you to optimise the use of heat during both summer and winter. Cyclone triple coil cylinders also offer the benefit of mains pressure hot water - powerful showers and fast filling baths.

Immersion Heater optionsIncoloy immersions come as standard in all Joule Cyclone Cylinders unless otherwise stated. Incoloy immersions are designed for low to medium use in a domestic application. If the water been stored is hard or the usage is high, Joule recommend Titanum Immersions.

Eco80With the requirement for more energy efficient solu-tions, Joule offer the full Cyclone range with Eco80 specification. The eco 80 range increasea insula-tion thickness to 80mm nominal.

Triple Coilefficient solar supported indirectly heated hot water complete with auxiliary heating coil

3/4” Boiler Flow

3/4” Secondary Return

1” Adaptable Cold Water Inlet

3/4” Boiler Return

3/4” Solar Flow

3/4” Boiler Flow

T&P Relief Valve (fitted)

Plain Aquastat Pocket

Plain Aquastat Pocket

Plain Solar Sensor

3/4” Solar Return

3/4” Boiler Flow

Plain Solar Sensor

1” Adaptable Hot Water Draw

Immersion Heater

Page 19: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

19 / 24

JOULE - manufacturing excellence

1 1 1 1 11 1 10Temperature and Pressure Relief Valve

Expansion Vessel

Dual ThermostatHigh Flow RateInlet Control Set

Incoloy Long 240V 3kW Immersion Heater

15/22 Tundish 22mm Thermostatic Mixing Valve

Expansion Vessel Hose

22 mm 2 Port Motorzed Diverting Valve

STANDARD SLIM LINE SPECIAL

Volume (l) 200 250 300 400 500 205 230 193 222 225 280 300 305 342 360

Height (mm) 1085 1335 1535 1535 1880 1880 2000 1335 1535 1205 1880 2000 1205 1335 1880

Diameter (mm) 560 560 560 660 660 440 440 500 500 560 500 500 660 660 560

Weight Empty (kg) 34 43 47 62 75 36 40 34 38 40 46 47 48 55 58

Weight Full (kg) 234 293 347 462 575 241 270 227 260 265 326 347 353 397 418

Reheat Indirect Total Minutes 26 26 32 35 35 28 32 26 30 31 31 34 34 30 32

Reheat 3 kW Immersion Total Min. 91 118 141 175 222 93 112 87 101 110 138 141 144 152 165

EN12897 Prim. Heat Exchng (kW) 18 22 22 28 35 18 18 18 18 18 22 22 22 28 28

EN12897 Solar Heat Exchng (kW) 16 18 18 22 22 16 18 16 18 18 18 18 18 22 22

EN12897 Aux. Heat Exchng (kW) 18 22 22 28 35 18 18 18 18 18 22 22 22 28 28

Dedicated Solar Volume 110 135 160 210 260 113 125 107 121 123 150 160 163 181 190

Standard Standing Loss kWh/Day 1.8 2.15 2.28 2.41 2.54 1.82 1.92 1.75 1.86 1.9 2.24 2.28 2.3 2.35 2.38

Eco80 Standing Loss kWh/Day 1.59 1.69 1.91 2.15 2.25 1.61 1.64 1.56 1.62 1.66 1.72 1.91 1.92 2.10 2.12

Technical Information 19 / 28

JOULE IRELANDT +353 1 6237080 F +353 1 6269337 E [email protected] W www.joule.ie

When using Eco80, dimensions will change to allow for extra insulation.

Page 20: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

Quad Coilefficient solar supported indirectly heated hot water complete with two auxiliary heating coils

Immersion Heater optionsIncoloy immersions come as standard in all Joule Cyclone Cylinders unless otherwise stated. Incoloy immersions are designed for low to medium use in a domestic application. If the water been stored is hard or the usage is high, Joule recommend Titanum Immersions.

Eco80With the requirement for more energy efficient solu-tions, Joule offer the full Cyclone range with Eco80 specification. The eco 80 range increasea insula-tion thickness to 80mm nominal.

3/4” Boiler Flow

3/4” Secondary Return

1” Adaptable Cold Water Inlet

3/4” Boiler Return

3/4” Solar Flow

3/4” Boiler Return

T&P Relief Valve (fitted)

Plain Aquastat Pocket

Plain Aquastat Pocket

Plain Solar Sensor

3/4” Solar Return

3/4” Boiler Flow

Plain Solar Sensor

1” Adaptable Hot Water Draw

Immersion Heater

3/4” Boiler Return

3/4” Boiler Flow

Page 21: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

21 / 24

JOULE - manufacturing excellence

1 1 1 1 11 1 00Temperature and Pressure Relief Valve

Expansion Vessel

Dual ThermostatHigh Flow RateInlet Control Set

Incoloy Long 240V 3kW Immersion Heater

15/22 Tundish 22mm Thermostatic Mixing Valve

Expansion Vessel Hose

22 mm 2 Port Motorzed Diverting Valve

STANDARD

Volume (l) 250 300 400 500

Height (mm) 1335 1535 1535 1880

Diameter (mm) 560 560 660 660

Weight Empty (kg) 45 49 62 75

Weight Full (kg) 295 349 462 575

Reheat Indirect Total Minutes 26 32 35 35

Reheat 3 kW Immersion Total Min. 118 141 175 222

EN12897 Prim. Heat Exchng (kW) 22 22 28 35

EN12897 Solar Heat Exchng (kW) 18 18 22 22

Auxiliary Coil Heat Exchng 1 (kW) 22 22 28 35

Auxiliary Coil Heat Exchng 2 (kW) 22 22 28 35

Dedicated Solar Volume 135 160 210 260

Standard Standing Loss kWh/Day 2.15 2.28 2.41 2.54

Eco80 Standing Loss kWh/Day 1.69 1.91 2.15 2.25

Technical Information 21 / 28

JOULE IRELANDT +353 1 6237080 F +353 1 6269337 E [email protected] W www.joule.ie

When using Eco80, dimensions will change to allow for extra insulation.

Page 22: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

Joule Cyclone Heatpump cylinders have been designed to work with air source, ground source and other types of low temperature heat source appliances. The cylinder is manufactured with coil in coil technology. Coil in coil technology allows for greater surface area coils to be installed in standard sized cylinder units. The inner coil dis-sipates more heat at lower temperatures improving the efficiency of the overall system. the cylinders can be manufactured with any size coil required. Please call Joule for details of coil sizes of units on the shelf and feel free to ask Joule for a differ-ent specification cylinder if that is what you require. Our in house engineers are on hand to offer advice on cylinder specifications for different applications.

Heat Pumpspecifically designed to work with heat pumps and other low temperature heat sources

Immersion Heater optionsIncoloy immersions come as standard in all Joule Cyclone Cylinders unless otherwise stated. Incoloy immersions are designed for low to medium use in a domestic application. If the water been stored is hard or the usage is high, Joule recommend Titanum Immersions.

Eco80With the requirement for more energy efficient solu-tions, Joule offer the full Cyclone range with Eco80 specification. The eco 80 range increasea insula-tion thickness to 80mm nominal.

1” Heat Pump Flow

3/4” Secondary Return

1” Adaptable Cold Water Inlet

1” Heat Pump Return

3/4” Solar Flow

1/2” T&P Relief Valve (fitted)

Plain Solar Sensor

Plain Aquastat Pocket

Plain Solar Sensor3/4” Solar Return

Plain Solar Sensor

1” Adaptable Hot Water Draw

Immersion Heater

Plain Solar Sensor

Page 23: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

23 / 24

JOULE - manufacturing excellence

STANDARD SLIM LINE SPECIAL

Volume (l) 170 200 250 300 400 500 175 205 230 193 222 225 270 280 300 305 342 360

Height (mm) 1205 1085 1335 1535 1535 1880 1535 1880 2000 1335 1535 1205 1085 1880 2000 1205 1335 1880

Diameter (mm) 500 560 560 560 660 660 440 440 440 500 500 560 660 500 500 660 660 560

Weight Empty (kg) 32 34 43 47 62 75 34 36 40 34 38 40 45 46 47 48 55 58

Weight Full (kg) 202 234 293 347 462 575 209 241 270 227 260 265 315 326 347 353 397 418

Reheat Indirect Total Minutes 24 26 26 32 35 35 27 28 32 26 30 31 30 31 34 34 30 32

Reheat 3 kW Immersion Total Min. 75 91 118 141 175 222 76 93 112 87 101 110 135 138 141 144 152 165

EN12897 Prim. Heat Exchng (kW) 19 21 25 25 31 38 19 21 21 21 21 21 25 25 25 25 31 31

EN12897 Solar Heat Exchng (kW) 16 16 18 18 22 22 16 16 18 16 18 18 18 18 18 18 22 22

Dedicated Solar Volume 95 110 135 160 210 260 98 113 125 107 121 123 145 150 160 163 181 190

Standard Standing Loss kWh/Day 1.53 1.8 2.15 2.28 2.41 2.54 1.55 1.82 1.92 1.75 1.86 1.9 2.2 2.24 2.28 2.3 2.35 2.38

Eco80 Standing Loss kWh/Day 1.45 1.59 1.69 1.91 2.15 2.25 1.46 1.61 1.64 1.56 1.62 1.66 1.70 1.72 1.91 1.92 2.00 2.10

1 1 1 1 11 1 10Temperature and Pressure Relief Valve

Expansion Vessel

Dual ThermostatHigh Flow RateInlet Control Set

Incoloy Long 240V 3kW Immersion Heater

15/22 Tundish 22mm Thermostatic Mixing Valve

Expansion Vessel Hose

22 mm 2 Port Motorzed Diverting Valve

Technical Information 23 / 28

JOULE IRELANDT +353 1 6237080 F +353 1 6269337 E [email protected] W www.joule.ie

When using Eco80, dimensions will change to allow for extra insulation.

3/4” Secondary Return

1” Adaptable Cold Water Inlet

1/2” T&P Relief Valve (fitted)

Page 24: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

Horizontal CylinderThe Joule Cyclone Horizontal product line provides alternative solution to Cyclone Direct, Direct Solar, Indirect, Twin Coil, cylinders.

Horizontal Cylinderefficient horizontal water heating option

Immersion Heater optionsIncoloy immersions come as standard in all Joule Cyclone Cylinders unless otherwise stated. Incoloy immersions are designed for low to medium use in a domestic application. If the water been stored is hard or the usage is high, Joule recommend Titanum Immersions.

Eco80With the requirement for more energy efficient solu-tions, Joule offer the full Cyclone range with Eco80 specification. The eco 80 range increasea insula-tion thickness to 80mm nominal.

3/4” Secondary Return

3/4” Boiler Flow

1/2” T&P Relief Valve (fitted)

1” Adaptable Hot Water Draw

3/4” Boiler Flow

3/4” Boiler Return

Immersion Heater

1” Adaptable Cold Water Inlet

Plain Aquastat Pocket

Plain Aquastat Pocket

3/4” Boiler Flow

Page 25: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

25 / 24

JOULE - manufacturing excellence

STANDARD DIRECT STANDARD INDIRECT SOLAR TWIN COIL

Volume (l) 125 150 170 200 250 300 400 500 125 150 170 200 250 300 400 500 125 150 170 200 250 300 400 500

Height (mm) 500 500 500 560 560 560 660 660 500 500 500 560 560 560 660 660 500 500 500 560 560 560 660 660

Lenght (mm) 925 1085 1205 1085 1335 1535 1535 1880 925 1085 1205 1085 1335 1535 1535 1880 925 1085 1205 1085 1335 1535 1535 1880

Weight Empty (kg) 26 30 32 34 43 47 62 75 26 30 32 34 43 47 62 75 26 30 32 34 43 47 62 75

Weight Full (kg) 151 180 202 234 293 347 462 575 151 180 202 234 293 347 462 575 151 180 202 234 293 347 462 575

Reheat Indirect Total Minutes - - - - - - - - 19 21 24 26 26 32 35 35 19 21 24 26 26 32 35 35

Reheat 3 kW Immersion Total Min. 48 63 75 91 118 141 175 222 48 63 75 91 118 141 175 222 48 63 75 91 118 141 175 222

EN12897 Prim. Heat Exchng (kW) - - - - - - - - 16 16 16 18 22 22 28 35 16 16 16 18 22 22 28 35

EN12897 Solar Heat Exchng (kW) - - - - - - - - - - - - - - - - 16 16 16 16 18 18 22 22

Dedicated Solar Volume - - - - - - - - - - - - - - - - 75 85 95 110 135 160 210 260

Standard Standing Loss kWh/Day 1.23 1.41 1.53 1.8 2.15 2.28 2.41 2.54 1.23 1.41 1.53 1.8 2.15 2.28 2.41 2.54 1.23 1.41 1.53 1.8 2.15 2.28 2.41 2.54

Eco80 Standing Loss kWh/Day 1.05 1.35 1.45 1.59 1.69 1.91 2.15 2.25 1.12 1.35 1.45 1.6 1.69 1.91 2.15 2.25 1.05 1.35 1.45 1.59 1.69 1.91 2.15 2.25

1 1 1 1 11 1 10Temperature and Pressure Relief Valve

Expansion Vessel

Dual ThermostatHigh Flow RateInlet Control Set

Incoloy Long 240V 3kW Immersion Heater

15/22 Tundish 22mm Thermostatic Mixing Valve

Expansion Vessel Hose

22 mm 2 Port Motorzed Diverting Valve

Technical Information 25 / 28

JOULE IRELANDT +353 1 6237080 F +353 1 6269337 E [email protected] W www.joule.ie

When using Eco80, dimensions will change to allow for extra insulation.

Page 26: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

Stainless Litestainless vented cylinder

Notes

Page 27: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

27 / 24

JOULE - manufacturing excellence

Notes 27 / 28

JOULE IRELANDT +353 1 6237080 F +353 1 6269337 E [email protected] W www.joule.ie

Page 28: Unvented and Vented IE - Home Insulation, Heating ... · effiency coil to ensure all our units perform to the ... with multi fuel heating systems in mind. ... The tank is completely

JOULE IE

A Kylemore Park West, Ballyfermot, Dublin 10T +353 1 6237080 F +353 1 6269337 E [email protected] W www.joulesolutions.ie

UN-VENTED AND VENTED STAINLESS STEEL HOT WATER CYLINDERS

JOULE UKA Newport Business Park, Newbridge Road, Ellesmere Port, Chesire, CH65 4LZT t +44 (0) 1513 551 094 F +44 (0) 1513 568 336 E [email protected] W www.jouleuk.co.uk

JOULE PL

A 23-200 Kraśnik, ul. Towarowa 34. E [email protected] W www.joule-pl.pl