UnomedicalUnomedicalAirway ManagementAirway Management
Safety • Functionality • ReliabilitySafety • Functionality • Reliability
2
SuctioningSuctioning
AnaesthesiaAnaesthesia
RespiratoryRespiratory
Unomedical Airway ManagementUnomedical Airway Management
Specimen collectionSpecimen collection
3
Unomedical Airway ManagementUnomedical Airway ManagementRespiratory productsRespiratory products
Oxygen MasksOxygen Masks& Cannulas& Cannulas
NebulizingNebulizingSystemsSystems
ResuscitatorsResuscitators
Oxygen CannulasOxygen Cannulas& Catheters& Catheters
4
Unomedical Airway ManagementUnomedical Airway ManagementAnaesthesia productsAnaesthesia products
Endotracheal Endotracheal TubesTubes
Tracheostomy Tracheostomy TubesTubes
Laryngeal Laryngeal AirwaysAirways
5
Cathy ClosedCathy ClosedSuction SystemSuction System
Open SuctionOpen SuctionCathetersCatheters
SpecimenSpecimencollectioncollection
Unomedical Airway ManagementUnomedical Airway ManagementSuction & specimen collectionSuction & specimen collection
6
Standard Standard Tracheostomy Tracheostomy
TubesTubes
Laryngeal AirwaysLaryngeal Airways
Endotracheal TubesEndotracheal Tubes
Speciality Speciality Tracheostomy Tracheostomy
TubesTubes
Open Suction Open Suction CathetersCatheters
Closed SuctionClosed SuctionSystemsSystems
ResuscitatorsResuscitators
Anaesthesia MasksAnaesthesia Masks
UnomedicalUnomedicalAirway ManagementAirway Management
Safety Safety •• Functionality Functionality • • ReliabilityReliability
7
Unomedical Endotracheal TubesUnomedical Endotracheal Tubes
8
Unomedical Endotracheal TubesUnomedical Endotracheal Tubes
Unomedical Preformed Endotracheal TubesUnomedical Preformed Endotracheal Tubes• Oral Preformed & Nasal PreformedOral Preformed & Nasal Preformed
Unomedical Standard Endotracheal TubesUnomedical Standard Endotracheal Tubes• Cuffed & UncuffedCuffed & Uncuffed
Unomedical Reinforced Endotracheal TubesUnomedical Reinforced Endotracheal Tubes• Cuffed & UncuffedCuffed & Uncuffed
9
Unomedical ETT Suction Unomedical ETT Suction
10
Safety, Functionality, ReliabilitySafety, Functionality, Reliability
SafetySafetyEasy identification
Improved position controlEffective seal (HVLP Cuff)
Atraumacitic transition
FunctionalityFunctionalityUnomedical Colour Coding
Perfect adaptation Accurate positioning
Radiopaque
RELIABILITYRELIABILITY
11
Unomedical Tracheostomy TubesUnomedical Tracheostomy Tubes
12
Unomedical Tracheostomy TubesUnomedical Tracheostomy Tubes
Unomedical Standard Tracheostomy TubesUnomedical Standard Tracheostomy Tubes
• Cuffed & Uncuffed
Unomedical Tracheostomy Tubes with Inner Cannula (TTIC)
• Fenestrated & Non-fenestrated
Unomedical Tracheostomy Tubes with Inner Cannula & Subglottic Suctioning (TTIC Suction)
• Fenestrated & Non-fenestrated
13
Safety, Functionality, ReliabilitySafety, Functionality, Reliability
SafetySafetyGentle adaptation
Reduced risk of displacementAtraumatic transition
Effective sealEasy indentification & traceability
FunctionalityFunctionalityUnomedical Colour Coding
Thermosensitive & TransparentSuitable for percutaneous insertion
Wide range of solutions
RELIABILITYRELIABILITY
14
Unomedical TTIC SuctionUnomedical TTIC Suction
Glottic opening
Cuff
Subglottic room
Integrated suction line with suction port above cuff• Effective removal of subglottic secretions
• Reduction of Ventilator Associated Pneumonia (VAP)1
1 Mahul et al.: “Prevention of nosocomial pneumonia in intubated patients:respective role of mechanical subglottic secretions drainage and stress ulcer prophylaxis.“ Intensive Care Med 1992, 18:20-25.1 Valles et al.: “Continuous aspiration of subglottic secretions in preventing ventilator-associated pneumonia.” Ann Intern Med 1995, 122:179-1861 Smulders et al.: “A randomized clinical trial of intermittent subglottic secretion drainage in patients receiving mechanical ventilation.” Chest 2002, 121:858-862
17
CathyCathyTMTM Closed Suction System Closed Suction SystemSafety • Functionality • ReliabilitySafety • Functionality • Reliability
18
CathyCathyTMTM Closed Suction System Closed Suction System
Slim semi- transparent protective sleeve
Transparent material
Mülly-tipped catheter, Metric markings
Unomedical Colour Coding
Ergonomic design
Universal connector
FunctionalityFunctionality
RELIABILITYRELIABILITY
Built-in non-return valve
Indication of open/closed position
Swivel standard connector
Disconnecting ring
Unique 5µ filter protection
Control button with safety lid
SafetySafety
19
Assess, identify, formulateAssess, identify, formulate
Assess the competitionIdentify the audience
Formulate the message
20
Assess, identify, formulateAssess, identify, formulate
Assess the competition
Cathyvs
Open Suction
Cathyvs
Closed Suction
21
Assess, identify, formulateAssess, identify, formulate
Identify the audience
End-userEnd-user
Decision makerDecision maker
InfluencerInfluencer
ClinicianClinician
PurchaserPurchaser
NurseNurse
NurseNurse
PurchaserPurchaser
ClinicianClinician
NurseNurse
ClinicianClinician
PurchaserPurchaser
22
Assess, identify, formulateAssess, identify, formulate
Formulate the message
End-userEnd-user
Decision makerDecision maker
InfluencerInfluencer
NurseNurse
ClinicianClinician
NurseNurse
23
Background:Endotracheal suctioning is able to create extremely high flows that are potentially able to eliminate the complete volume delivered to the lungs by the ventilator
High sub-atmospheric suction pressure can result in:- Partial or total elimination of gas volume in the lungs- Alveolar collapse- Atelektasis- Hypoaemia- Hypercapnia
Endotracheal SuctioningEndotracheal Suctioning
The extent of the effect is directly related to the size of the suction catheter used.
Choosing the right catheter can be difficult.
Stenqvist O, Lindgren S, Karason S, Sondergaard S, Lundin S. Warning! Suctioning. A lung model evaluation of closed suctioning systems. Acta anaesthesiologica Scandinavica VOL:45(2); p.167-72/2001Almgren B, Wickerts CJ, Heinonen E, Hogman M. Side effects of endotracheal suction in pressure- and volume controlled ventilation. Chest 2004;125:1077-80Almgren, B; Endotracheal Suction a Reopened Problem. Acta Universitatis Upsaliensis. Digital Comprehensive Summaries of Uppsalla Dissertations from the Faculty of Medicine 11.55pp. Uppsala; 2005AARC Clinical Practice Guideline. Endotracheal Suctioning of Mechanically Ventilated Adults and Children with Artificial Airways. Respir Care 1993;38:500-504
24
What are nurses saying?What are nurses saying?
Endotracheal suctioning is very physicalWrong sized suction catheters Need to use “end-feel” to estimate depth of catheter insertionShort time-frame for suctioning ventilated patient
25
CathyCathyTMTM Closed Suction System Closed Suction System
Slim semi- transparent protective sleeve
Transparent material
Mülly-tipped catheter, Metric markings
Unomedical Colour Coding
Ergonomic design
Universal connector
FunctionalityFunctionality
RELIABILITYRELIABILITY
Built-in non-return valve
Indication of open/closed position
Swivel standard connector
Disconnecting ring
Unique 5µ filter protection
Control button with safety lid
SafetySafety
27
Disconnection ring Disconnection ring
• Cathy is gently and easily pushed off the tube
• Ensures secure attachment and easy disconnection
Turn in the direction of the arrows
30
Filter protection Filter protection
5 µm hydrophobic filter
36
Mülly-tip catheter with metric markingsMülly-tip catheter with metric markings
• The specially designed Mülly tip catheter helps to prevent mucosa trauma
• The Mülly catheter is designed with 2 small relieving eyes and a full bore distal eye
37
Mucosa trauma Mucosa trauma
Complications like mucosal trauma may occur due to :
• High vacuum
• Design of catheter
• Size of the catheter
• Wrongly performed technique