INVITATION TO BID ADDENDUM
UCHC ITB-10 Form Rev. 2/15
UNIVERSITY OF CONNECTICUT HEALTH CENTER Procurement Operations & Contracts
263 Farmington Avenue, MC4036 Farmington, CT 06032-4036
Buyer
Telephone Number
E-mail Address
Fax Number
ITB NUMBER: BID DUE DATE: BID DUE TIME: ITB SURETY:
EST
ITB TITLE:
ADDENDUM NUMBER:
DATE ADDENDUM ISSUED:
FOR: The University of Connecticut Health Center
NOTE:
This Addendum must be Signed & Returned with your bid.
________________________________ ______________________________ Authorized Signature of Bidder Company Name
Approved By: ______________________________________ [ ]
Buyer (Original Signature on Document in Procurement Files)
Page 1 of 10
UConn Health ASB Precast Panel Stabilization Project 19-603.01Addendum #1
The pre-bid walk-through for the UConn Health ASB Building Precast Panel Stabilization project was conducted on June 13, 2019 at the project site. The following provides additional clarification of items discussed and questions raised during the walk-through:
1. Work Location: The intent of the project is to lift the panels onto new shims while minimizing disruption to building tenants. Therefore, our intent is that all jacking procedures be performed from the exterior of the building. The interior spaces may be accessed for adjustment of the lateral anchors as required to facilitate jacking operations.2. Project Schedule: Contractors should perform the work using the following stipulations.a. Work resulting in excessive noise that would be disruptive to normal business operations must be performed off
1. Work Location: The intent of the project is to lift the panels onto new shims while minimizingdisruption to building tenants. Therefore, our intent is that all jacking procedures be performed from theexterior of the building. The interior spaces may be accessed for adjustment of the lateral anchors as requiredto facilitate jacking operations.2. Project Schedule: Contractors should perform the work using the following stipulations.a. Work resulting in excessive noise that would be disruptive to normal business operations must beperformed off hours or on weekends.b. Site safety must be maintained at all times.
page 2 of 10
UNIVERSITY OF CONNECTICUT
ADMINISTRATIVE SERVICES BUILDING
PRECAST PANEL STABILIZATION
I. PROJECT MANUAL
Division O - General Conditions
Division 1 - General Requirements
01015 01018 01020 01045 01300 01700 01740
TABLE OF CONTENTS
Notice and Instructions to Bidders
Contractor Qualification Statement
Bid Fonn
Bid Bond
Perfonnance Bond
Payment Bond
Standard Fonn of Agreement Between Owner and Contractor, AIA A-101 (2007)
General Conditions, AIA A-201 (2007)
Application for Payment, AIA G-702 and Continuation Sheet AIA G-703
List of Subcontractors, UCHC FORM 550.13A
UCHC Background lnfonnation Sheet
General Project Requirements Special Project Procedures Construction Area Environmental Control Cutting and Patching Submittals Project Close-out Warranties and Bonds
Page 3 of 10
Wiss, Janney, Elstner Associates, Inc.
2 Trap Falls Road, Suite 502
Shelton, Connecticut 06484
203.944.9424 tel | 203.944.6997 fax
www.wje.com
ENGINEERSARCHITECTSMATERIALS SCIENTISTS
I
S
S
U
E
D
F
O
R
B
I
D
-
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
ADMINISTRATIVE SERVICES
BUILDING PRECAST PANEL
STABILIZATION
263 FARMINGTON AVENUE
FARMINGTON, CT 06030
UCONN HEALTH
263 FARMINGTON AVENUE
FARMINTON, CT 06030
ADDENDUM #1
BID SET
2018.5248
2
1
6/26/2019
6/5/2019
TMA
5/4/2019
As Noted
JML
COVERSHEET
C-000
1
A
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
B
C
D
E
F
A
B
C
D
E
F
Project
DescriptionMark Date
Project No.
Date
Drawn
Checked
Scale
Sheet Title
Sheet No.
Headquarters & Laboratories : Northbrook, IllinoisAtlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | DetroitHonolulu | Houston | Los Angeles | Minneapolis | New Haven | New York
Philadelphia | Princeton | San Francisco | Seattle | South Florida | Washington, D.C.
© C
opyr
ight
201
8. A
ll rig
hts r
eser
ved.
No
part
of th
is d
ocum
ent m
ay b
e re
prod
uced
in a
ny fo
rm o
r by
any
mea
ns w
ithou
tpe
rmis
sion
from
Wis
s, Ja
nney
, Els
tner
Ass
ocia
tes,
Inc.
(WJE
). W
JE d
iscl
aim
s any
resp
onsi
bilit
y fo
r its
una
utho
rized
use
.
Plot
ted:
6/2
6/20
19 1
1:18
AM
by
Ario
sto,
Tim
Fi
le N
ame:
P:\2
018\
2018
.5xx
x\20
18.5
248.
0 - U
CO
NN
HEA
LTH
PR
ECA
ST P
AN
ELS
(TM
A)\D
raw
ings
\She
ets\
C-0
00C
OV
ERSH
EET.
dwg
THIS SHEET PLOTS FULL SIZE
AT 24x36 (INCHES)
0 1/2" 1" 2"
Consultants
Client
WJE Project Number:
WJE Wiss, Janney, Elstner Associates, Inc.Two Trap Falls Road, Suite 502Shelton, Connecticut 06484
2018.5248
SCOPE OF WORK - SUMMARY
Location Map
THE GENERAL SCOPE OF WORK INVOLVES LIFTING OF TWENTY (20) 30' LONG x 8' HIGH x 5"
THICK ARCHITECTURAL PRECAST CONCRETE PANELS TO ACCOMMODATE REMOVAL OF
EXISTING PLASTIC SHIMS AND INSTALLATION OF NEW STEEL SHIMS. ALL OF THE PRECAST
PANELS TO BE LIFTED FROM THE ROOF OR THE EXTERIOR.
IT IS ANTICIPATED THAT THIS WORK WILL BE ACCOMPLISHED THROUGH THE FOLLOWING
PROCEDURE:
1. LOCALLY REMOVE ROOF BASE FLASHINGS, ROOFING MATERIALS (ROOF MEMBRANE,
INSULATION, COVERBOARD), WOOD BLOCKING, AND CORRUGATED STEEL DECK TO
EXPOSE BEARING CONNECTIONS AT PRECAST PANELS. PERMIT WJE INSPECTION.
2. LIFT PRECAST PANELS FROM COLUMN CAPS AS REQUIRED TO ALLOW FOR REMOVAL
OF EXISTING PLASTIC SHIMS AND INSTALLATION OF NEW STEEL SHIMS.
3. ANCHOR NEW STEEL SHIM STACK TO EXISTING STRUCTURE.
4. REMOVE AND REPLACE METAL DECKING AND WOOD BLOCKING AS REQUIRED AT
PANEL BEARING LOCATIONS.
5. REINSTALL ROOFING MATERIALS. PROVIDE NEW BASE FLASHINGS AND PATCH ROOF.
263 FARMINGTON AVENUE, FARMINGTON, CT 06030
ADMINISTRATIVE SERVICES BUILDING -
PRECAST PANEL STABILIZATION
PROJECT LOCATION
GENERAL NOTES
· ALL WORK SHALL BE IN ACCORDANCE WITH THESE DRAWINGS DATED JUNE 5, 2019.
· ALL WORK SHALL COMPLY WITH THE BUILDING CODES, RULES AND REGULATIONS
APPLICABLE IN THE MUNICIPALITY OF FARMINGTON, THE STATE OF CONNECTICUT
AND ANY OTHER AUTHORITY HAVING JURISDICTION.
· THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AT THE JOB SITE
PRIOR TO STARTING THE WORK, AND SHALL NOTIFY THE ARCHITECT/ENGINEER OF
ANY DISCREPANCIES, OMISSIONS, OR OTHER CONDITIONS WHICH MAY AFFECT THE
SCOPE OF WORK IMMEDIATELY, PRIOR TO BEGINNING REPAIRS IMPACTED BY THE
NOTED CONDITIONS. DO NOT SCALE DRAWINGS.
· THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT AS
REQUIRED TO COMPLETE THE WORK.
· THE CONTRACTOR SHALL PROVIDE SIDEWALK PROTECTION IN THE FORM OF
BARRICADES, PEDESTRIAN CANOPIES OR SIDEWALK SHEDS AS REQUIRED BY THE
OWNER AND/OR LOCAL ORDINANCES.
· ALL PERMITS TO BE SECURED BY OWNER. CONTRACTOR TO COMPLY WITH TERMS
OF PERMIT.
· THE CONTRACTOR SHALL PROPERLY PROTECT AND MAKE SAFE ADJACENT
PROPERTIES AND OWNER'S PROPERTY AS JOB CONDITIONS REQUIRE.
· UNANTICIPATED CONDITIONS OR DISTRESSED BUILDING ELEMENTS ENCOUNTERED
DURING THE COURSE OF THE WORK WHICH REQUIRE REPAIRS SHALL BE BROUGHT
TO THE ATTENTION OF THE ARCHITECT/ENGINEER AND THE OWNER. NO
ADDITIONAL WORK SHALL BE PERFORMED UNLESS APPROVED IN ADVANCE BY THE
OWNER.
· THE DRAWINGS AND SPECIFICATIONS ARE TO BE TAKEN IN THEIR ENTIRETY AND
AS A WHOLE. IF A DISCREPANCY IS FOUND BETWEEN THE DRAWINGS AND
SPECIFICATIONS, THE ARCHITECT/ENGINEER SHALL DETERMINE WHICH GOVERNS,
AS IS CONSISTENT WITH THE INTENT OF THE DESIGN.
· THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL SITE SAFETY AND
METHODS AND MEANS OF CONSTRUCTION. THE CONTRACTOR SHALL MAKE ANY
INSPECTIONS OR ANALYSIS NECESSARY TO VERIFY THAT EXISTING BUILDING
ELEMENTS HAVE ADEQUATE LOAD CAPACITY TO SUPPORT ANY REQUIRED FORCES
HE/SHE CHOOSES TO IMPOSE ON THEM.
· THE BUILDING SHALL REMAIN OCCUPIED DURING THE COURSE OF THE WORK AND
CONSTRUCTION RELATED ACTIVITIES SHALL BE THOROUGHLY COORDINATED WITH
THE OWNER AND SHALL NOT BLOCK EXISTING MEANS OF EGRESS OR PEDESTRIAN
WALKWAYS. WORK SHALL BE PHASED SO THAT SAFE ACCESS TO THE BUILDING IS
MAINTAINED AT ALL TIMES AND THAT BUILDING OPERATIONS ARE NOT DISTURBED.
· CONTRACTOR TO COORDINATE PHASING OF WORK WITH OWNER TO MINIMIZE
DISRUPTION TO BUILDING OCCUPANTS.
ADDENDUM #1 - Issued June 26, 2019
NOT FOR CONSTRUCTION
UConn Health Project Number: 19-603.01
INDEX OF DRAWINGS
Sheet Number Sheet Title
C-000 COVERSHEET
S-100 SITE PLAN
S-101 ROOF FRAMING PLAN
S-102 ENLARGED PLANS
S-200 NORTH AND EAST ELEVATION
S-201 WEST AND SOUTH ELEVATION
S-300 DETAILS
S-301 DETAILS
MATERIAL SPECIFICATION
· SEALANT JOINTS - DOW 790
· SELF TAPPING SCREWS - TEKS SELECT OR APPROVED EQUAL
· TEFLON COATED BEARING PLATE -FABREEKA SBX OR APPROVED EQUAL
· STEEL SHIMS - A36 STEEL
· ROOFING MATERIALS - FIRESTONE RUBBERGARD EPDM OR APPROVED EQUAL
ROOF HATCH
MAIN ENTRANCE TO BUILDING.
PROVIDE SAFE ACCESS TO
BUILDING THROUGHOUT REPAIRS
S-201
1
S-200
1
S-201
2
MAINTAIN SAFE ACCESS TO ALL
SIDEWALKS LEADING TO BUILDING.
S-200
2
TRUCK ACCESS TO LOADING DOCK
TO REMAIN OPEN AT ALL TIMES.
APPROXIMATE LOCATION OF UNDERGROUND FUEL
TANK. COORDINATE LOCATION WITH OWNER PRIOR
TO UTILIZATION HEAVY EQUIPMENT IN THIS AREA.
PROTECT EXISTING ROOFTOP EQUIPMENT AS
REQUIRED DURING CONSTRUCTION. NOTE THAT
ALL EQUIPMENT MUST REMAIN ONLINE. TYPICAL.
DOWLING WAY
ADMINISTRATIVE
SERVICES BUILDING
LOADING DOCK
PARKING
AREA
LOADING DOCK
PROTECT EXISTING EPDM ROOFING
MEMBRANE AS REQUIRED DURING
CONSTRUCTION ACTIVITIES.
FIRE EXIT FOR BUILDING.
MAINTAIN SAFE ACCESS AND
EGRESS AT ALL TIMES.
LIMIT PEDESTRIAN ACCESS TO
LANDSCAPED AREAS AROUND BUILDING AS
REQUIRED TO SAFELY PERFORM WORK.
BASIS OF DESIGN:
2018 CT STATE BUILDING CODE: CHAPTER 34
· WORK IS CLASSIFIED AS A REPAIR
· NO ALTERATIONS TO OCCUPANCY
· NO CHANGES TO GRAVITY OR LATERAL LOAD RESISTANCE OF STRUCTURE.
DEAD LOADS
· ROOF DEAD LOAD - 20 PSF UNIFORM
LIVE LOADS
· CONSTRUCTION LIVE LOADS - 20 PSF UNIFORM
· FACTORED JACKING LOAD - 10.7 KIPS ON COLUMN CAPS AT ENDS OF EACH
PANEL.
GENERAL NOTES:
1. CONTRACTOR LAYDOWN AREA ON ROOF TO BE DETERMINED. COORDINATE
WITH OWNER AND WJE.
2. LIMIT PEDESTRIAN ACCESS TO LANDSCAPED AREAS AROUND BUILDING AS
REQUIRED TO SAFELY PERFORM WORK.
Wiss, Janney, Elstner Associates, Inc.
2 Trap Falls Road, Suite 502
Shelton, Connecticut 06484
203.944.9424 tel | 203.944.6997 fax
www.wje.com
ENGINEERSARCHITECTSMATERIALS SCIENTISTS
I
S
S
U
E
D
F
O
R
B
I
D
-
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
ADMINISTRATIVE SERVICES
BUILDING PRECAST PANEL
STABILIZATION
263 FARMINGTON AVENUE
FARMINGTON, CT 06030
UCONN HEALTH
263 FARMINGTON AVENUE
FARMINTON, CT 06030
ADDENDUM #1
BID SET
2018.5248
2
1
6/26/2019
6/5/2019
TMA
5/4/2019
As Noted
JML
SITE PLAN
S-100
1
A
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
B
C
D
E
F
A
B
C
D
E
F
Project
DescriptionMark Date
Project No.
Date
Drawn
Checked
Scale
Sheet Title
Sheet No.
Headquarters & Laboratories : Northbrook, IllinoisAtlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | DetroitHonolulu | Houston | Los Angeles | Minneapolis | New Haven | New York
Philadelphia | Princeton | San Francisco | Seattle | South Florida | Washington, D.C.
© C
opyr
ight
201
8. A
ll rig
hts r
eser
ved.
No
part
of th
is d
ocum
ent m
ay b
e re
prod
uced
in a
ny fo
rm o
r by
any
mea
ns w
ithou
tpe
rmis
sion
from
Wis
s, Ja
nney
, Els
tner
Ass
ocia
tes,
Inc.
(WJE
). W
JE d
iscl
aim
s any
resp
onsi
bilit
y fo
r its
una
utho
rized
use
.
Plot
ted:
6/2
6/20
19 1
1:18
AM
by
Ario
sto,
Tim
Fi
le N
ame:
P:\2
018\
2018
.5xx
x\20
18.5
248.
0 - U
CO
NN
HEA
LTH
PR
ECA
ST P
AN
ELS
(TM
A)\D
raw
ings
\She
ets\
S-10
0 SI
TEPL
AN
.dw
g
THIS SHEET PLOTS FULL SIZE
AT 24x36 (INCHES)
0 1/2" 1" 2"
Consultants
Client
1SCALE: 1/16" = 1'-0"
SITE PLAN
N
W10X54 OUTRIGGERS
AT COLUMNS. TYP.
10'-0"
V.I.F.
10'-0"
V.I.F.
10'-0"
V.I.F.
LIFT PANELS TO ACCOMMODATE
REPLACEMENT OF SHIMS.
S-101
3
TYPICAL AT
COLUMNS
W21X50 SPANDREL BEAM
W12X55 COLUMN
WITH 3/4" CAP PLATE.
W12X55 COLUMN
WITH 3/4" CAP PLATE.
RECOMMENDED LIFTING POINT
RECOMMENDED LIFTING POINT
B
C
W18X35
W18X35
W18X35
W18X35
S-101
3
TYPICAL AT
COLUMNS
GENERAL NOTES:
· ALL WORK TO BE PERFORMED FROM BUILDING EXTERIOR.
· TOTAL WEIGHT OF PRECAST PANEL = ±18,000 LBS.
· DESIGN INTENT IS TO UTILIZE STRUCTURAL FRAMING TO LIFT
PRECAST PANELS. RECOMMENDED JACKING POINTS ARE
INDICATED.
· STRUCTURAL FRAMING PLAN BASED ON "UNIVERSITY OF
CONNECTICUT HEALTH CENTER ADMINISTRATIVE OFFICE
BUILDING 'D'" BY BURTON & VAN HOUTEN ENGINEERS, INC
DATED 12-12-1988. NOTIFY ENGINEER OF ANY DISCREPANCY
OBSERVED DURING CONSTRUCTION.
· PROVIDE JACKING PLAN AND PROCEDURE FOR A/E REVIEW
PRIOR TO PERFORMING ANY WORK.
LEGEND:
PANEL NUMBER
RECOMMENDED LOCATION FOR JACKING OF PRECAST PANELS.
LOCATIONS OF REMOVAL OF ROOFING MATERIALS AND
REPLACEMENT OF SHIMS.
#
±1" JOINT BETWEEN
ADJACENT PANELS.
REMOVE AND REPLACE
SEALANT JOINT AND
BACKER ROD
EXISTING W21X50 SPANDREL BEAM
EXISTING L6X4X3/8"
STEEL ANGLE WITH
DOWNTURNED LEG
6" HAUNCH
EXISTING BRACING BETWEEN
OUTRIGGER BEAMS - L3X3X1/4" STEEL
ANGLE WITH DOWNTURNED LEG
ANTICIPATED LIMIT OF
REMOVAL OF ROOFING
MATERIALS ±2'-0" V.I.F.
ANTICIPATED LIMIT OF
REMOVAL OF ROOFING
MATERIALS
±3'-0" V.I.F.
EXISTING LATERAL ANCHOR - L6X6X3/4"
STEEL ANGLE WITH UPTURNED LEG
S-300
3
LIFT PANELS TO ACCOMODATE REPLACEMENT
OF EXISTING SHIM STACK. SEE DETAIL 1/S-300
5" ARCHITECTURAL
PRECAST PANEL
ACCEPTABLE JACKING POINT FOR
PRECAST PANELS.
EXISTING 3/4" PLATE AT TOP OF COLUMN
FASTEN LOWEST (EXTENDED) SHIM TO L3X3
ANGLE WITH (4) 1/4" SELF TAPPING SCREWS.
EXISTING OUTRIGGER BEAM TO
SUPPORT PRECAST - W10X54
30
'-0
"
V.I.F
.
30
'-0
"
V.I.F
.
30
'-0
"
V.I.F
.
30
'-0
"
V.I.F
.
30
'-0
"
V.I.F
.
30'-0"
V.I.F.
30'-0"
V.I.F.
30'-0"
V.I.F.
30'-0"
V.I.F.
F
1 2 3 4 5 6
E
D
C
B
A
30'-0"
V.I.F.
S-101
2
LIFT ARCHITECTURAL PRECAST
PANEL TO ACCOMMODATE
REPLACEMENT OF SHIMS. EACH
PANEL IS SUPPORTED BY (2) SHIM
STACKS = 40 SHIM STACKS TOTAL.
S-200
2
S-200
1
S-201
2
S-201
1
DROPPED PRECAST PANEL TO BE
LIFTED BACK INTO ORIGINAL
POSITION.
#6 #7
#12
#20#19#18#17#16
#8 #9#10
#11
#13
#14
#15
#5
#4
#3
#2
#1
OBSERVED DURING CONSTRUCTION.
· PROVIDE JACKING PLAN AND PROCEDURE FOR A/E REVIEW
PRIOR TO PERFORMING ANY WORK.
Wiss, Janney, Elstner Associates, Inc.
2 Trap Falls Road, Suite 502
Shelton, Connecticut 06484
203.944.9424 tel | 203.944.6997 fax
www.wje.com
ENGINEERSARCHITECTSMATERIALS SCIENTISTS
I
S
S
U
E
D
F
O
R
B
I
D
-
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
ADMINISTRATIVE SERVICES
BUILDING PRECAST PANEL
STABILIZATION
263 FARMINGTON AVENUE
FARMINGTON, CT 06030
UCONN HEALTH
263 FARMINGTON AVENUE
FARMINTON, CT 06030
ADDENDUM #1
BID SET
2018.5248
2
1
6/26/2019
6/5/2019
TMA
5/4/2019
As Noted
JML
ROOF FRAMING PLAN
S-101
1
A
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
B
C
D
E
F
A
B
C
D
E
F
Project
DescriptionMark Date
Project No.
Date
Drawn
Checked
Scale
Sheet Title
Sheet No.
Headquarters & Laboratories : Northbrook, IllinoisAtlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | DetroitHonolulu | Houston | Los Angeles | Minneapolis | New Haven | New York
Philadelphia | Princeton | San Francisco | Seattle | South Florida | Washington, D.C.
© C
opyr
ight
201
8. A
ll rig
hts r
eser
ved.
No
part
of th
is d
ocum
ent m
ay b
e re
prod
uced
in a
ny fo
rm o
r by
any
mea
ns w
ithou
tpe
rmis
sion
from
Wis
s, Ja
nney
, Els
tner
Ass
ocia
tes,
Inc.
(WJE
). W
JE d
iscl
aim
s any
resp
onsi
bilit
y fo
r its
una
utho
rized
use
.
Plot
ted:
6/2
6/20
19 1
1:18
AM
by
Ario
sto,
Tim
Fi
le N
ame:
P:\2
018\
2018
.5xx
x\20
18.5
248.
0 - U
CO
NN
HEA
LTH
PR
ECA
ST P
AN
ELS
(TM
A)\D
raw
ings
\She
ets\
S-10
2 R
OO
FFR
AM
ING
PLA
N.d
wg
THIS SHEET PLOTS FULL SIZE
AT 24x36 (INCHES)
0 1/2" 1" 2"
Consultants
Client
1SCALE: 3/32" = 1'-0"
ROOF FRAMING PLAN
N
2
SCALE: 1/4" = 1'-0"
FRAMING PLAN AT TYPICAL EDGE BAY
3SCALE: 1 1/2" = 1'-0"
BEARING CONNECTION AT COLUMN (PLAN)
6 5 4 3 2 1
SECOND FLOOR
EL. 331'-0"
FIRST FLOOR
EL. 318'-0"
THIRD FLOOR
EL. 344'-0"
ROOF
EL. 356'-6
1
2
"
8'-0"
V.I.F.
#20 #19 #18 #17 #16
S-300
3
TYP AT
COLUMNS
PRIMARY ENTRANCE TO BUILDING.
MAINTAIN SAFE ACCESS TO
BUILDING AT ALL TIMES.
LIFT PANEL TO ACCOMMODATE
REPLACEMENT OF SHIMS. TYP.
REPLACE SEALANT AND
BACKER ROD BELOW PRECAST
PANELS TO BE LIFTED. TYPICAL.
SEE DETAIL 3/S-301
REPLACE SEALANT AND BACKER ROD AT BOTH SIDES OF
ALL VERTICAL JOINTS BETWEEN PRECAST PANELS TO BE
LIFTED. SEE DETAIL 3/S-301. TYPICAL
6 5 4 3 2 1
SECOND FLOOR
EL. 331'-0"
FIRST FLOOR
EL. 318'-0"
THIRD FLOOR
EL. 344'-0"
ROOF
EL. 356'-6
1
2
"
8'-0"
V.I.F.
FIRE EXIT. MAINTAIN SAFE EGRESS AT
ALL TIMES DURING REPAIR WORK.
#5 #4 #3
#2
#1
S-300
3
TYP AT
COLUMNS
MAINTAIN TRUCK ACCESS TO
LOADING DOCK AT ALL TIMES.
LIFT PANEL TO ACCOMMODATE
REPLACEMENT OF SHIMS. TYP.
DROPPED PRECAST PANEL TO BE LIFTED
BACK TO ORIGINAL POSITION.
REPLACE SEALANT AND
BACKER ROD BELOW PRECAST
PANELS TO BE LIFTED. TYPICAL.
SEE DETAIL 3/S-301
REPLACE SEALANT AND BACKER ROD AT BOTH SIDES OF
ALL VERTICAL JOINTS BETWEEN PRECAST PANELS TO BE
LIFTED. SEE DETAIL 3/S-301. TYPICAL
LEGEND:
LIFT PANEL TO ACCOMMODATE
REPLACEMENT OF SHIMS
PANEL NUMBER
REPLACE SEALANT AND
BACKER ROD. SEE DETAIL
3/S-301.
NOTES:
· ALL WORK TO BE PERFORMED FROM
EXTERIOR OF BUILDING.
· TOTAL WEIGHT OF PRECAST PANEL =
±18,000 LBS
· MAINTAIN SAFE ACCESS TO BUILDING
AND ALL SIDEWALKS LEADING TO
BUILDING AT ALL TIMES.
#
Wiss, Janney, Elstner Associates, Inc.
2 Trap Falls Road, Suite 502
Shelton, Connecticut 06484
203.944.9424 tel | 203.944.6997 fax
www.wje.com
ENGINEERSARCHITECTSMATERIALS SCIENTISTS
I
S
S
U
E
D
F
O
R
B
I
D
-
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
ADMINISTRATIVE SERVICES
BUILDING PRECAST PANEL
STABILIZATION
263 FARMINGTON AVENUE
FARMINGTON, CT 06030
UCONN HEALTH
263 FARMINGTON AVENUE
FARMINTON, CT 06030
ADDENDUM #1
BID SET
2018.5248
2
1
6/26/2019
6/5/2019
TMA
5/4/2019
As Noted
JML
NORTH AND EAST
ELEVATION
S-200
1
A
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
B
C
D
E
F
A
B
C
D
E
F
Project
DescriptionMark Date
Project No.
Date
Drawn
Checked
Scale
Sheet Title
Sheet No.
Headquarters & Laboratories : Northbrook, IllinoisAtlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | DetroitHonolulu | Houston | Los Angeles | Minneapolis | New Haven | New York
Philadelphia | Princeton | San Francisco | Seattle | South Florida | Washington, D.C.
© C
opyr
ight
201
8. A
ll rig
hts r
eser
ved.
No
part
of th
is d
ocum
ent m
ay b
e re
prod
uced
in a
ny fo
rm o
r by
any
mea
ns w
ithou
tpe
rmis
sion
from
Wis
s, Ja
nney
, Els
tner
Ass
ocia
tes,
Inc.
(WJE
). W
JE d
iscl
aim
s any
resp
onsi
bilit
y fo
r its
una
utho
rized
use
.
Plot
ted:
6/2
6/20
19 1
1:18
AM
by
Ario
sto,
Tim
Fi
le N
ame:
P:\2
018\
2018
.5xx
x\20
18.5
248.
0 - U
CO
NN
HEA
LTH
PR
ECA
ST P
AN
ELS
(TM
A)\D
raw
ings
\She
ets\
S-20
0 N
OR
THA
ND
EA
ST E
LEV
ATI
ON
.dw
g
THIS SHEET PLOTS FULL SIZE
AT 24x36 (INCHES)
0 1/2" 1" 2"
Consultants
Client
1SCALE: 1/8" = 1'-0"
NORTH ELEVATION
2SCALE: 1/8" = 1'-0"
EAST ELEVATION
6 5 4 3 2 1
SECOND FLOOR
EL. 331'-0"
FIRST FLOOR
EL. 318'-0"
THIRD FLOOR
EL. 344'-0"
ROOF
EL. 356'-6
1
2
"
8'-0"
V.I.F.
#10 #9 #8 #7 #6
S-300
3
TYP AT
COLUMNS
LIFT PANEL TO ACCOMMODATE
REPLACEMENT OF SHIMS. TYP.
REPLACE SEALANT AND
BACKER ROD BELOW PRECAST
PANELS TO BE LIFTED. TYPICAL.
SEE DETAIL 3/S-301
REPLACE SEALANT AND BACKER ROD AT BOTH SIDES OF
ALL VERTICAL JOINTS BETWEEN PRECAST PANELS TO BE
LIFTED. SEE DETAIL 3/S-301. TYPICAL
654321
SECOND FLOOR
EL. 331'-0"
FIRST FLOOR
EL. 318'-0"
THIRD FLOOR
EL. 344'-0"
ROOF
EL. 356'-6
1
2
"
8'-0"
V.I.F.
#14 #13 #12 #11#15
S-300
3
TYP AT
COLUMNS
PRIMARY ENTRANCE TO BUILDING.
MAINTAIN SAFE ACCESS TO
BUILDING AT ALL TIMES.
LIFT PANEL TO ACCOMMODATE
REPLACEMENT OF SHIMS. TYP.
REPLACE SEALANT AND
BACKER ROD BELOW PRECAST
PANELS TO BE LIFTED. TYPICAL.
SEE DETAIL 3/S-301
REPLACE SEALANT AND BACKER ROD AT BOTH SIDES OF
ALL VERTICAL JOINTS BETWEEN PRECAST PANELS TO BE
LIFTED. SEE DETAIL 3/S-301. TYPICAL
LEGEND:
LIFT PANEL TO ACCOMMODATE
REPLACEMENT OF SHIMS
PANEL NUMBER
REPLACE SEALANT AND
BACKER ROD. SEE DETAIL
3/S-301.
NOTES:
· ALL WORK TO BE PERFORMED FROM
EXTERIOR OF BUILDING.
· TOTAL WEIGHT OF PRECAST PANEL =
±18,000 LBS
· MAINTAIN SAFE ACCESS TO BUILDING
AND ALL SIDEWALKS LEADING TO
BUILDING AT ALL TIMES.
#
Wiss, Janney, Elstner Associates, Inc.
2 Trap Falls Road, Suite 502
Shelton, Connecticut 06484
203.944.9424 tel | 203.944.6997 fax
www.wje.com
ENGINEERSARCHITECTSMATERIALS SCIENTISTS
I
S
S
U
E
D
F
O
R
B
I
D
-
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
ADMINISTRATIVE SERVICES
BUILDING PRECAST PANEL
STABILIZATION
263 FARMINGTON AVENUE
FARMINGTON, CT 06030
UCONN HEALTH
263 FARMINGTON AVENUE
FARMINTON, CT 06030
ADDENDUM #1
BID SET
2018.5248
2
1
6/26/2019
6/5/2019
TMA
5/4/2019
As Noted
JML
WEST AND SOUTH
ELEVATION
S-201
1
A
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
B
C
D
E
F
A
B
C
D
E
F
Project
DescriptionMark Date
Project No.
Date
Drawn
Checked
Scale
Sheet Title
Sheet No.
Headquarters & Laboratories : Northbrook, IllinoisAtlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | DetroitHonolulu | Houston | Los Angeles | Minneapolis | New Haven | New York
Philadelphia | Princeton | San Francisco | Seattle | South Florida | Washington, D.C.
© C
opyr
ight
201
8. A
ll rig
hts r
eser
ved.
No
part
of th
is d
ocum
ent m
ay b
e re
prod
uced
in a
ny fo
rm o
r by
any
mea
ns w
ithou
tpe
rmis
sion
from
Wis
s, Ja
nney
, Els
tner
Ass
ocia
tes,
Inc.
(WJE
). W
JE d
iscl
aim
s any
resp
onsi
bilit
y fo
r its
una
utho
rized
use
.
Plot
ted:
6/2
6/20
19 1
1:18
AM
by
Ario
sto,
Tim
Fi
le N
ame:
P:\2
018\
2018
.5xx
x\20
18.5
248.
0 - U
CO
NN
HEA
LTH
PR
ECA
ST P
AN
ELS
(TM
A)\D
raw
ings
\She
ets\
S-20
1 W
EST
AN
D S
OU
TH E
LEV
ATI
ON
.dw
g
THIS SHEET PLOTS FULL SIZE
AT 24x36 (INCHES)
0 1/2" 1" 2"
Consultants
Client
2SCALE: 1/8" = 1'-0"
SOUTH ELEVATION
1
SCALE: 1/8" = 1'-0"
WEST ELEVATION
5" ARCHITECTURAL
PRECAST PANEL
6" WIDE HAUCH - CONTINUOUS
ACROSS PANEL LENGTH
EXISTING CAP PLATE ON
COLUMN - 14"X14"X3/4". TYPICAL
REMOVE EXISTING ROOFING MATERIALS
LOCAL TO BEARING POINTS AS REQUIRED TO
PERFORM REPAIR. REPLACE ALL MATERIALS
FOLLOWING REPAIR. SEE DETAIL #/S-300.
DROP CEILING AT INTERIOR
COLUMN - W12X55 TYPICAL
SPANDRAL BEAM -
W21X55 TYPICAL
8'-0"
V.I.F.
3'-9"
V.I.F.
4'-3"
V.I.F.
FIBERGLASS INSULATION AT INTERIOR
DISCRETE DOWNTURNED ANGLE AT
BEARING POINT - L4X6X3/8" X ± 18"
TYPICAL
CONTINUOUS ANGLE SPANNING BETWEEN
OUTRIGGERS - L3X3X1/4" TYPICAL.
OUTRIGGER BEAMS -
W10X54 TYPICAL.
LIFT PRECAST PANEL ONLY AS REQUIRED
TO LIFT OFF OF EXISTING SHIMS.
EXISTING LATERAL ANCHOR - L6x6x3/4" X ±14" WITH 1" THREADED
ROD. TYPICAL. NOTIFY ENGINEER IF ANCHORS ARE DISTRESSED.
LOOSEN FASTENERS AS REQUIRED TO JACK PANELS. ENSURE
BOLTS ARE SNUG FOLLOWING JACKING PROCEDURES.
EXISTING GRAVITY ANCHOR - ± 1 1/2" PLASTIC SHIMS. REMOVE
AND REPLACE WITH NEW STEEL SHIMS. SEE DETAIL 1/S-300.
REPLACE SEALANT
AND BACKER ROD,
SEE DETAIL 3/S-301
S-300
1
S-300
2
EXISTING LATERAL ANCHOR TO REMAIN.
LOOSEN ANCHOR AS REQUIRED TO JACK
PANELS. ENSURE BOLTS ARE SNUG
FOLLOWING JACKING PROCEDURES.
HAUNCH AT ARCHITECTURAL
PRECAST PANEL
REMOVE EXISTING PLASTIC SHIMS. PROVIDE NEW,
4"X4" CARBON STEEL SHIMS. PROVIDE 1" WELD (MIN.)
AT EACH SIDE OF SHIM STACK BETWEEN
SUBSEQUENT LAYERS OF SHIMS . SIZE SHIMS TO
MINIMIZE NUMBER OF SHIMS REQUIRED.
PROVIDE TEFLON COATED
CARBON STEEL SHIM AT TOP.
TACK WELD TO SHIM STACK.
PROVIDE EXTENDED SHIM AT BOTTOM
OF STACK TO ALLOW FOR FASTENING
TO EXISTING STEEL ANGLE.
EXISTING L6X4X3/8" ANGLE
WITH DOWNTURNED LEG
EXISTING OUTRIGGER BEAM
MATCH TOTAL THICKNESS
OF
SHIM STACK WITH
EXISTING. ±1
1
2
" V.I.F.
NOTE: DO NOT FIELD WELD IN PLACE OR ON THE
ROOF UNLESS PROTECTION AND HOT WORK
PROCEDURES ARE SUBMITTED AND APPROVED BY
THE OWNER.
REMOVE EXISTING PLASTIC SHIMS.
PROVIDE NEW, 4"X4" CARBON STEEL
SHIMS. PROVIDE 1" WELD (MIN.) AT
EACH SIDE OF SHIM BETWEEN
SUBSEQUENT LAYERS OF SHIMS.
SIZE SHIMS TO MINIMIZE NUMBER OF
SHIMS REQUIRED.
PROVIDE TEFLON COATED
CARBON STEEL SHIM AT TOP.
TACK WELD TO SHIM STACK.
PROVIDE EXTENDED SHIM AT BOTTOM
OF STACK. PRE-DRILL HOLES AND
FASTEN TO EXISTING L3X3X1/4" WITH
1/4" SELF TAPPING SCREWS..
EXISTING L6X4X3/8" ANGLE
WITH DOWNTURNED LEG
MATCH TOTAL THICKNESS
OF
SHIM STACK WITH
EXISTING. ±1
1
2
" V.I.F.
EXISTING L3X3X1/4" ANGLE
WITH DOWNTURNED LEG
EXISTING FIBERGLASS INSULATION
EXISTING LATERAL ANCHOR
TO REMAIN IN PLACE.
MONITOR DURING JACKING
OPERATION. LOOSEN AS
REQUIRED TO LIFT PANELS.
ENSURE BOLTS ARE SNUG
AFTER JACKING.
EXISTING OUTRIGGER BEAM
PROVIDE LEVELING SHIM AS
REQUIRED
NOTE: DO NOT FIELD WELD IN PLACE OR ON THE
ROOF UNLESS PROTECTION AND HOT WORK
PROCEDURES ARE SUBMITTED AND APPROVED BY
THE OWNER.
MINIMUM 7"
MINIMUM 7"
PROVIDE NEW 12 GA. STEEL SPLICE
PLATE WITH (2) SELF DRILLING
SCREWS AT EACH TOP FLUTE.
FOLLOWING INSTALLATION OF
NEW SHIMS, REPLACE STEEL
DECK REMOVED DURING WORK.
REPLACE FASTENERS TO EXISTING
STRUCTURE TO MATCH EXISTING SIZE,
NUMBER, AND CONFIGURATION.
EXISTING STEEL DECK TO REMAIN.
EXISTING STRUCTURAL
FRAMING (BELOW)
EXISTING FASTENERS TO
EXISTING STRUCTURE.
Wiss, Janney, Elstner Associates, Inc.
2 Trap Falls Road, Suite 502
Shelton, Connecticut 06484
203.944.9424 tel | 203.944.6997 fax
www.wje.com
ENGINEERSARCHITECTSMATERIALS SCIENTISTS
I
S
S
U
E
D
F
O
R
B
I
D
-
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
ADMINISTRATIVE SERVICES
BUILDING PRECAST PANEL
STABILIZATION
263 FARMINGTON AVENUE
FARMINGTON, CT 06030
UCONN HEALTH
263 FARMINGTON AVENUE
FARMINTON, CT 06030
ADDENDUM #1
BID SET
2018.5248
2
1
6/26/2019
6/5/2019
TMA
5/4/2019
As Noted
CHECKED BY
DETAILS
S-300
1
A
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
B
C
D
E
F
A
B
C
D
E
F
Project
DescriptionMark Date
Project No.
Date
Drawn
Checked
Scale
Sheet Title
Sheet No.
Headquarters & Laboratories : Northbrook, IllinoisAtlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | DetroitHonolulu | Houston | Los Angeles | Minneapolis | New Haven | New York
Philadelphia | Princeton | San Francisco | Seattle | South Florida | Washington, D.C.
© C
opyr
ight
201
8. A
ll rig
hts r
eser
ved.
No
part
of th
is d
ocum
ent m
ay b
e re
prod
uced
in a
ny fo
rm o
r by
any
mea
ns w
ithou
tpe
rmis
sion
from
Wis
s, Ja
nney
, Els
tner
Ass
ocia
tes,
Inc.
(WJE
). W
JE d
iscl
aim
s any
resp
onsi
bilit
y fo
r its
una
utho
rized
use
.
Plot
ted:
6/2
6/20
19 1
1:18
AM
by
Ario
sto,
Tim
Fi
le N
ame:
P:\2
018\
2018
.5xx
x\20
18.5
248.
0 - U
CO
NN
HEA
LTH
PR
ECA
ST P
AN
ELS
(TM
A)\D
raw
ings
\She
ets\
A-3
00D
ETA
ILS.
dwg
THIS SHEET PLOTS FULL SIZE
AT 24x36 (INCHES)
0 1/2" 1" 2"
Consultants
Client
3SCALE: 1" = 1'-0"
SECTION AT PRECAST PANEL AT COLUMN
1
SCALE: 6" = 1'-0"
NEW SHIM STACK (ELEVATION)
2
SCALE: 6" = 1'-0"
NEW SHIM STACK (SECTION)
4SCALE: 1" = 1'-0"
STEEL DECK SPLICE
2
2
2
2
2
LOOSE LAID EPDM ROOFING.
FOLLOWING REPLACEMENT OF
SHIMS, PATCH MEMBRANE PER
4/S-301.
GRAVEL BALLAST. DO NOT STOCKPILE IN A
MANNER THAT WOULD OVERLOAD ROOF.
EXPANDED POLYSTYRENE
INSULATION
COVERBOARD
STEEL DECKING
TERMINATION BAR, REPLACE
PER DETAIL 2/S-301 AT
REMOVAL AREA
WOOD BLOCKING. REMOVE
AND REPLACE AS REQUIRED.
ARCHITECTURAL PRECAST WALL
PANEL. REPLACE SEALANT AND
BACKER ROD BETWEEN PANELS.
NOTE: FOLLOWING
REPLACEMENT OF SHIMS,
REPLACE ALL REMOVED
ROOFING MATERIALS AND
PATCH ROOF.
JOINT
WIDTH (W)
SEALANT
DEPTH (D)
BACKER ROD
DIAMETER
1
4
"
1
4
"
3
8
"
3
8
"
1
4
"
1
2
"
1
2
"
1
4
"
5
8
"
5
8
"
1
4
" -
3
8
"
3
4
"
3
8
" -
1
2
"
1"
7
8
"
1
1
4
"
1"
1
1
4
"
1
1
4
"
1
2
"
1
1
2
"
1
1
2
"
2"
3
4
"
3
8
" -
1
2
"
3
8
" -
1
2
"
1
2
"
SEALANT DEPTH AND BACKER ROD DIAMETER (BUTT JOINT) SHALL BE BASED ON THE FOLLOWING TABLE:
B
W
D
PROVIDE CONCAVE JOINT. TOOL
SEALANT TO ELIMINATE AIR
POCKETS AND TO PROVIDE
CONTACT OF SEALANT TO SIDES
OF JOINT
BACKER ROD
BUTT JOINT:
NOTES:
1. BOND LINE (B) - MIN. 3/8" ON CONCRETE; MIN. 1/4" ON METAL OR
GLASS
2. SEALANT DEPTH (D) - MIN. 1/4"
3. TOOL SEALANT TO ELIMINATE AIR POCKETS AND TO PROVIDE
CONTACT OF SEALANT TO SIDES OF JOINT. PROVIDE
"HOURGLASS" PROFILE WHERE POSSIBLE (B>D)
4. CLEAN AND PREPARE SURFACE ACCORDING TO
MANUFACTURER REQUIREMENTS.
S.S. TERMINATION BAR WITH S.S.
FASTENERS AT 8" O.C. APPLY
WATER CUT-OFF MASTIC BEHIND
EPDM UNDER TERMINATION BAR.
SEALANT
EPDM MEMBRANE
BONDING ADHESIVE
EXISTING SUBSTRATE
EXISTING LOOSE LAID EPDM
MEMBRANE
PROVIDE NEW REINFORCED 90 MIL
FIRESTONE RUBBERGARD EPDM
MEMBRANE AT REMOVAL AREA.
3" MIN.
FIRESTONE QUICKSEAM SPLICE
TAPE OR APPROVED EQUAL. CLEAN
AND PRIME BOTH SIDES OF EPDM
MEMBRANE PER MANUFACTURER
INSTRUCTIONS.
LAP SEALANT
Wiss, Janney, Elstner Associates, Inc.
2 Trap Falls Road, Suite 502
Shelton, Connecticut 06484
203.944.9424 tel | 203.944.6997 fax
www.wje.com
ENGINEERSARCHITECTSMATERIALS SCIENTISTS
I
S
S
U
E
D
F
O
R
B
I
D
-
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
ADMINISTRATIVE SERVICES
BUILDING PRECAST PANEL
STABILIZATION
263 FARMINGTON AVENUE
FARMINGTON, CT 06030
UCONN HEALTH
263 FARMINGTON AVENUE
FARMINTON, CT 06030
ADDENDUM #1
BID SET
2018.5248
2
1
6/26/2019
6/5/2019
TMA
5/4/2019
As Noted
JML
DETAILS
S-301
1
A
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
B
C
D
E
F
A
B
C
D
E
F
Project
DescriptionMark Date
Project No.
Date
Drawn
Checked
Scale
Sheet Title
Sheet No.
Headquarters & Laboratories : Northbrook, IllinoisAtlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | DetroitHonolulu | Houston | Los Angeles | Minneapolis | New Haven | New York
Philadelphia | Princeton | San Francisco | Seattle | South Florida | Washington, D.C.
© C
opyr
ight
201
9. A
ll rig
hts r
eser
ved.
No
part
of th
is d
ocum
ent m
ay b
e re
prod
uced
in a
ny fo
rm o
r by
any
mea
ns w
ithou
tpe
rmis
sion
from
Wis
s, Ja
nney
, Els
tner
Ass
ocia
tes,
Inc.
(WJE
). W
JE d
iscl
aim
s any
resp
onsi
bilit
y fo
r its
una
utho
rized
use
.
Plot
ted:
6/2
6/20
19 1
1:19
AM
by
Ario
sto,
Tim
Fi
le N
ame:
P:\2
018\
2018
.5xx
x\20
18.5
248.
0 - U
CO
NN
HEA
LTH
PR
ECA
ST P
AN
ELS
(TM
A)\D
raw
ings
\She
ets\
S-30
1 R
OO
FIN
GD
ETA
ILS.
dwg
THIS SHEET PLOTS FULL SIZE
AT 24x36 (INCHES)
0 1/2" 1" 2"
Consultants
Client
1SCALE: 1 1/2" = 1'-0"
EXISTING ROOFING SYSTEM
3
SCALE: 3" = 1'-0"
SEALANT JOINT REPAIR
2SCALE: 1' = 1'-0"
TERMINATION BAR
4
SCALE: 3" = 1'-0"
TIE IN TO EXISTING ROOF