University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered...

41
University Apartments on Brooklyn PROJECT MANUAL SIGNAGE 101400 Caron Architecture LLC © 2014 Section 101400 – Signage PART 1 - GENERAL 1.1 SECTION INCLUDES A. Street address sign. B. Canopy Signage C. Signage for unit entry doors. D. Signage for stairwells. E. Signage for barrier free site access. F. Signage for Common areas. 1.2 RELATED WORK A. Section 012100 - Allowances. B. Division 260000 - Electrical 1.3 SUBMITTALS A. Submit samples under provisions of Section 013300. B. Submit two samples illustrating full size sample sign, of type, style and color specified including method of attachment. C. Include installation template and hardware. 1.4 DELIVERY, STORAGE, AND HANDLING A. Deliver products to site under provisions of Section 016000. B. Store and protect products under provisions of Section 016000. C. Package signs, labelled in name groups. D. Store adhesive tape at ambient room temperatures.

Transcript of University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered...

Page 1: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

SIGNAGE 101400Caron Architecture LLC © 2014

Section 101400 – Signage

PART 1 - GENERAL

1.1 SECTION INCLUDES

A. Street address sign.

B. Canopy Signage

C. Signage for unit entry doors.

D. Signage for stairwells.

E. Signage for barrier free site access.

F. Signage for Common areas.

1.2 RELATED WORK

A. Section 012100 - Allowances.

B. Division 260000 - Electrical

1.3 SUBMITTALS

A. Submit samples under provisions of Section 013300.

B. Submit two samples illustrating full size sample sign, of type, style and color specified including method of attachment.

C. Include installation template and hardware.

1.4 DELIVERY, STORAGE, AND HANDLING

A. Deliver products to site under provisions of Section 016000.

B. Store and protect products under provisions of Section 016000.

C. Package signs, labelled in name groups.

D. Store adhesive tape at ambient room temperatures.

Page 2: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

SIGNAGE 101400Caron Architecture LLC © 2014

PART 2 - PRODUCTS

2.1 MATERIALS

A. Signs: Size, color, materials and style to be approved by Architect/Owner.

B. Mounting hardware and tape adhesive to suit applicator.

C. Custom signs: Size, color and style to be approved by Architect/Owner.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Verify that surfaces are ready to receive work.

B. Beginning of installation means installer accepts existing surfaces.

3.2 INSTALLATION

A. Install signs after all surfaces are finished, in locations indicated by Architect/Owner.

B. Locate signs as directed by Architect/Owner.

C. Clean and polish.

END OF SECTION 101400

Page 3: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered
Page 4: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

TUB AND SHOWER DOORS 102819Caron Architecture LLC © 2014

SECTION 102819 - TUB AND SHOWER DOORSTIPS:To view non-printing Editor's Notes that provide guidance for editing, click on Masterworks/Single-FileFormatting/Toggle/Editor's Notes.To read detailed research, technical information about products and materials, and coordination checklists, click on Masterworks/Supporting Information.

PART 1 - GENERAL

1.1 SUMMARY

A. Section includes frameless shower doors and enclosures.

1.2 ACTION SUBMITTALS

A. Product Data: For each type of product.

B. LEED Submittals:

1. Product Data for Credit IEQ 4.1: For sealants, documentation including printed statement of VOC content.

C. Shop Drawings: For tub and shower doors and enclosures.

D. Samples: For each type of exposed finish.

1.3 INFORMATIONAL SUBMITTALS

A. Sample warranties.

1.4 CLOSEOUT SUBMITTALS

A. Maintenance data.

1.5 WARRANTY

A. Special Warranty: Manufacturer agrees to repair or replace components of tub and shower doors and enclosures that fail in materials or workmanship within specified warranty period without monetary limitation.

1. Warranty Period: [Two] [Three] <Insert number> years from date of Substantial Completion.

Page 5: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

TUB AND SHOWER DOORS 102819Caron Architecture LLC © 2014

PART 2 - PRODUCTS

2.1 FRAMELESS ENCLOSURES

A. Frameless glass panels with mounting and operating hardware of types and sizes required to support imposed loads.

1. Manufacturers: Subject to compliance with requirements, [provide products by the following] [provide products by one of the following] [available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following]:

2. Basis-of-Design Product: Subject to compliance with requirements, provide [productindicated on Drawings] <Insert manufacturer's name; product name or designation> or comparable product by one of the following:

a. Agalite; Hartung Glass Industries.

b. Alumax; Sapa Extrusions, Inc.

c. American Shower Door.

d. Artistcraft Shower Doors.

e. Basco Corporation.

f. Cardinal Shower Enclosures; Hoskin & Muir, Inc.

g. Century Bathworks.

h. Fleurco Shower Doors.

i. Kohler Co.

j. Southeastern Aluminum Products, Inc.

k. <Insert manufacturer's name>.

B. Hardware and Trim: Manufacturer's standard units as indicated and as required for complete installation.

1. Materials:

a. Aluminum:

1) Finish: [Clear anodic] [Color anodic] [Baked enamel or powder coat]<Insert finish>.

2) Color: [Silver] [Gold] [Black] <Insert color>.

Page 6: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

TUB AND SHOWER DOORS 102819Caron Architecture LLC © 2014

b. Brass:

1) Finish: [Chrome] [Satin chrome] [Brass] [Satin brass] [Oil-rubbed brass][Bronze] [Brushed bronze] [Oil-rubbed bronze] <Insert finish>.

c. Stainless Steel:

1) Finish: [No. 4 directional satin finish] [No. 6 dull satin finish] [No. 7reflective, directional finish] <Insert finish>.

C. Bypass Doors: Sliding units suspended from extruded-aluminum header track by fully adjustable, sealed, heavy-duty ball-bearing rollers. Self-draining sill tracks with nylon panel guides. Molded jamb bumpers with concealed fasteners.

1. Door Pulls: Full-door-width, single-sided towel bars.2. Safety Clip System: Manufacturer's standard safety device designed to prevent doors

from falling off sliding track.

D. Swinging Doors: Hinged for [90 degrees out] [135 degrees] [180 degrees] swing. Self-centeringwhen doors are within 15 degrees of closed position. Soft bulb seal or wipes; affixed to door to direct water back into enclosure and provide a tight water seal.

1. Hinges: [Side hinged] [Top-and-bottom pivots].2. Door Pulls: [Single-sided towel bar] [Back-to-back towel bars] [Knobs].

a. Towel Bar Length: [18 inches (457 mm)] [24 inches (610 mm)] [30 inches (762mm)] <Insert dimension>.

E. Fixed Panels: [Side] [Top-and-bottom] mounts; match hinges in material and finish.

F. Ventilating Transom: Rotating clamps centered on transom.

G. Glazing: Comply with requirements in Section 088000 "Glazing."

H. Glazing: Safety glazing materials complying with 16 CFR 1201, Category II, with permanently etched identification acceptable to authorities having jurisdiction.

1. Glass Nominal Thickness: [As determined by manufacturer based on panel size] [8 mm][10 mm] [12 mm] <Insert thickness>.

2. Clear Glass: ASTM C 1048, Type I, Quality-Q3, Class I (clear), Kind FT.3. Protective, Self-Cleaning, Glass Coating: Clear float glass with a coating on first surface

having both photocatalytic and hydrophilic properties that act to loosen dirt and to cause water to sheet evenly over the glass instead of beading.

I. Fasteners: Manufacturer's standard stainless-steel or other noncorrosive fasteners.

J. Sealant: Mildew-resistant, single-component, nonsag, neutral-curing silicone joint sealant; ASTM C 920, Type S, Grade NS, Class 25, for Use NT.

Page 7: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

TUB AND SHOWER DOORS 102819Caron Architecture LLC © 2014

1. Sealant shall have a VOC content of 250 g/L or less.

K. Materials:

1. Aluminum: Alloy and temper recommended by manufacturer for type of use and finish indicated.

a. Sheet and Plate: ASTM B 209 (ASTM B 209M).b. Extrusions: ASTM B 221 (ASTM B 221M).

2. Stainless-Steel Sheet: ASTM A 666, Type 302 or 304.3. Stainless-Steel Bars and Shapes: ASTM A 276, Type 302 or 304.4. Copper-Alloy Sheet and Shapes: ASTM B 36/B 36M.5. Copper-Alloy Extrusions: ASTM B 455, alloy UNS No. C38500 (architectural brass).

PART 3 - EXECUTION

3.1 INSTALLATION

A. Prepare and install as recommended in manufacturer's written instructions unless more stringent requirements are contained in GANA's "Glazing Manual."

B. Clean substrates, removing projections, filling voids, and sealing joints.

C. Set units level, plumb, and true to line, without warp or rack of frames and panels, and anchor securely in place.

D. Fasten components securely in place, with provisions for thermal movement. Install with concealed fasteners unless otherwise indicated.

E. Install components to drain and return water to tub or shower.

F. Install doors to produce smooth operation and tight fit at contact points.

G. Repair, refinish, or replace components damaged during installation.

3.2 ADJUSTING AND CLEANING

A. Adjust operating parts and hardware for smooth, quiet operation and watertight closure.Lubricate hardware and moving parts.

B. Remove nonpermanent labels, and clean surfaces immediately after installation.

END OF SECTION 102819

Page 8: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

FIRE PROTECTION CABINETS 104413Caron Architecture LLC © 2014

SECTION 104413 - FIRE PROTECTION CABINETSTIPS:To view non-printing Editor's Notes that provide guidance for editing, click on Masterworks/Single-FileFormatting/Toggle/Editor's Notes.To read detailed research, technical information about products and materials, and coordination checklists, click on Masterworks/Supporting Information.

PART 1 - GENERAL

1.1 SUMMARY

A. Section includes fire-protection cabinets for portable fire extinguishers.

1.2 ACTION SUBMITTALS

A. Product Data: For each type of product.

B. Shop Drawings: For fire-protection cabinets.

1.3 CLOSEOUT SUBMITTALS

A. Maintenance data.

1.4 COORDINATION

A. Coordinate size of fire-protection cabinets to ensure that type and capacity of fire extinguishers indicated are accommodated.

B. Coordinate sizes and locations of fire-protection cabinets with wall depths.

1.5 SEQUENCING

A. Apply [decals] [vinyl lettering] on field-painted fire-protection cabinets after painting is complete.

PART 2 - PRODUCTS

2.1 PERFORMANCE REQUIREMENTS

Page 9: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

FIRE PROTECTION CABINETS 104413Caron Architecture LLC © 2014

A. Fire-Rated Fire-Protection Cabinets: Listed and labeled to comply with requirements in ASTM E 814 for fire-resistance rating of walls where they are installed.

2.2 FIRE-PROTECTION CABINET <Insert drawing designation>

A. Cabinet Type: Suitable for fire extinguisher.

1. Products: Subject to compliance with requirements, [provide the following] [provideone of the following] [available products that may be incorporated into the Work include, but are not limited to, the following]:

2. Basis-of-Design Product: Subject to compliance with requirements, provide [productindicated on Drawings] <Insert manufacturer's name; product name or designation> or comparable product by one of the following:

a. Fire-End & Croker Corporation.

b. GMR International Equipment Corporation.

c. Guardian Fire Equipment, Inc.

d. JL Industries, Inc.; a division of the Activar Construction Products Group.

e. Larsens Manufacturing Company.

f. Modern Metal Products, Division of Technico Inc.

g. Nystrom, Inc.

h. Potter Roemer LLC.

i. Strike First Corporation of America.

j. <Insert manufacturer's name; product name or designation>.

B. Cabinet Construction: [Nonrated] [1-hour fire rated] [2-hour fire rated].

1. Fire-Rated Cabinets: Construct fire-rated cabinets with double walls fabricated from 0.043-inch- (1.09-mm-) thick cold-rolled steel sheet lined with minimum 5/8-inch- (16-mm-) thick fire-barrier material. Provide factory-drilled mounting holes.

C. Cabinet Material: [Cold-rolled steel sheet] [Aluminum sheet] [Stainless-steel sheet].

D. Recessed Cabinet:

1. Trimless with Concealed Flange: Surface of surrounding wall finishes flush with exterior finished surface of cabinet frame and door, without overlapping trim attached to

Page 10: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

FIRE PROTECTION CABINETS 104413Caron Architecture LLC © 2014

cabinet. Provide recessed flange, of same material as box, attached to box to act as [plaster stop] [drywall bead].

2. Trimless with Hidden Flange: Flange of same metal and finish as box overlaps surrounding wall finish and is concealed from view by an overlapping door.

3. Exposed Flat Trim: One-piece combination trim and perimeter door frame overlapping surrounding wall surface with exposed trim face and wall return at outer edge (backbend).

E. Semirecessed Cabinet: One-piece combination trim and perimeter door frame overlapping surrounding wall surface with exposed trim face and wall return at outer edge (backbend).

1. Square-Edge Trim: 1-1/4- to 1-1/2-inch (32- to 38-mm) backbend depth.2. Rolled-Edge Trim: [2-1/2-inch (64-mm)] [4-inch (102-mm)] [4-1/2-inch (114-mm)]

<Insert dimension> backbend depth.

F. Surface-Mounted Cabinet: Cabinet box fully exposed and mounted directly on wall with no trim.

G. Cabinet Trim Material: [Steel sheet] [Aluminum sheet] [Extruded-aluminum shapes] [Stainless-steel sheet] [Copper-alloy brass sheet] [Copper-alloy bronze sheet] [Same material and finish as door].

H. Door Material: [Steel sheet] [Aluminum sheet] [Extruded-aluminum shapes] [Stainless-steelsheet] [Copper-alloy brass sheet] [Copper-alloy bronze sheet].

I. Door Style: [Fully glazed, frameless, backless, acrylic panel] [Fully glazed panel with frame] [Full acrylic bubble, frameless] [Full acrylic bubble with frame] [Full acrylic bubble with frameless, rotating turntable] [Horizontal duo panel with frame] [Vertical duo panel with frame] [Center glass panel with frame] [Solid opaque panel with frame] [Flush opaque panel, frameless, with no exposed hinges].

J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered break glass] [Wire glass] [Acrylic sheet] [Break acrylic bubble] [Molded acrylic bubble].

1. Acrylic Sheet Color: [Clear] [Bronze] transparent acrylic sheet.2. Acrylic Sheet Color: Clear transparent acrylic sheet painted [white] [red] [black] on

unexposed side.3. Acrylic Bubble Color: [Clear] [Bronze] [Red], transparent.

K. Door Hardware: Manufacturer's standard door-operating hardware of proper type for cabinet type, trim style, and door material and style indicated.

L. Accessories:

1. Break-Glass Strike: Manufacturer's standard metal strike, complete with chain and mounting clip, secured to cabinet.

Page 11: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

FIRE PROTECTION CABINETS 104413Caron Architecture LLC © 2014

2. Door Lock: [Cam lock that allows door to be opened during emergency by pulling sharply on door handle] [Cylinder lock, keyed alike to other cabinets].

3. Identification: Lettering complying with authorities having jurisdiction for letter style, size, spacing, and location. Locate [as indicated] [as directed by Architect] <Insertlocation>.

a. Identify fire extinguisher in fire-protection cabinet with the words "[FIREEXTINGUISHER] <Insert identification>."

1) Location: Applied to [cabinet door] [cabinet glazing] [location indicated on Drawings].

2) Application Process: [Silk-screened] [Engraved] [Etched] [Decals][Pressure-sensitive vinyl letters].

3) Lettering Color: [Red] [Black] [White].4) Orientation: [Vertical] [Horizontal] [As indicated on Drawings].

M. Materials:

1. Cold-Rolled Steel: ASTM A 1008/A 1008M, Commercial Steel (CS), Type B.

a. Finish: [Factory primed for field painting] [Baked enamel or powder coat].b. Color: [Match Architect's sample] [As selected by Architect from full range of

industry colors and color densities] <Insert color>.

2. Aluminum: ASTM B 221 (ASTM B 221M), with strength and durability characteristics of not less than Alloy 6063-T5 for aluminum sheet. ASTM B 221 (ASTM B 221M) forextruded shapes.

a. Finish: [Clear anodic] [Color anodic] [Baked enamel or powder coat].b. Color: [Light bronze] [Medium bronze] [Dark bronze] [Match Architect's sample]

[As selected by Architect from full range of industry colors and color densities]<Insert color>.

3. Stainless Steel: ASTM A 666, Type 304.

a. Finish: [No. 4 directional satin finish] [No. 8 mirrorlike reflective, nondirectional polish] <Insert finish>.

4. Copper Alloy, Brass: ASTM B 36/B 36M, alloy [as standard with manufacturer] <Insertrequirements>.

a. Finish: [Polished] [Satin] [As selected by Architect from full range of industry finishes] <Insert finish>.

5. Copper Alloy, Bronze: ASTM B 36/B 36M, alloy [as standard with manufacturer] <Insertrequirements>.

Page 12: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

FIRE PROTECTION CABINETS 104413Caron Architecture LLC © 2014

a. Finish: [Mirror polish] [Satin polish] [Satin oxidized oil rub] [Clear baked enamel][Match Architect's sample] [As selected by Architect from full range of industry finishes] <Insert finish>.

6. Clear Float Glass: ASTM C 1036, Type I, Class 1, Quality q3, [3] [6] mm thick.7. Tempered Float Glass: ASTM C 1048, Kind FT, Condition A, Type I, Quality q3, 3 mm

thick, [Class 1 (clear)] [Class 2 (tinted, heat absorbing, and light reducing), bronze tint].8. Break Glass: Clear annealed float glass, ASTM C 1036, Type I, Class 1, Quality q3, 1.5 mm

thick, single strength.9. Tempered Break Glass: ASTM C 1048, Kind FT, Condition A, Type I, Quality q3, 1.5 mm

thick.10. Wire Glass: ASTM C 1036, Type II, Class 1, Form 1, Quality q8, Mesh m1 (diamond), 6

mm thick.11. Transparent Acrylic Sheet: ASTM D 4802, Category A-1 (cell-cast sheet), [1.5] [3] [6] mm

thick, with [Finish 1 (smooth or polished)] [Finish 2 (patterned, textured)].

2.3 FABRICATION

A. Fire-Protection Cabinets: Provide manufacturer's standard box (tub) with trim, frame, door, and hardware to suit cabinet type, trim style, and door style indicated.

PART 3 - EXECUTION

3.1 INSTALLATION

A. Prepare recesses for [recessed] [and] [semirecessed] fire-protection cabinets as required by type and size of cabinet and trim style.

B. Install fire-protection cabinets in locations and at mounting heights indicated[ or, if not indicated, at heights acceptable to authorities having jurisdiction.]

C. Fire-Protection Cabinets: Fasten cabinets to structure, square and plumb.

D. Identification: Apply [decals] [vinyl lettering] at locations indicated.

E. Adjust fire-protection cabinet doors to operate easily without binding. Verify that integrallocking devices operate properly.

END OF SECTION 104413

Page 13: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

FIRE EXTINGUISHERS 104416Caron Architecture LLC © 2014

SECTION 104416 - FIRE EXTINGUISHERSTIPS:To view non-printing Editor's Notes that provide guidance for editing, click on Masterworks/Single-FileFormatting/Toggle/Editor's Notes.To read detailed research, technical information about products and materials, and coordination checklists, click on Masterworks/Supporting Information.

PART 1 - GENERAL

1.1 SUMMARY

A. Section includes portable, hand-carried fire extinguishers[ and mounting brackets for fire extinguishers].

1.2 ACTION SUBMITTALS

A. Product Data: For each type of product.

1.3 INFORMATIONAL SUBMITTALS

A. Warranty: Sample of special warranty.

1.4 CLOSEOUT SUBMITTALS

A. Operation and maintenance data.

1.5 COORDINATION

A. Coordinate type and capacity of fire extinguishers with fire-protection cabinets to ensure fit and function.

1.6 WARRANTY

A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace fire extinguishers that fail in materials or workmanship within specified warranty period.

1. Warranty Period: [Six] <Insert number> years from date of Substantial Completion.

PART 2 - PRODUCTS

Page 14: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

FIRE EXTINGUISHERS 104416Caron Architecture LLC © 2014

2.1 PERFORMANCE REQUIREMENTS

A. NFPA Compliance: Fabricate and label fire extinguishers to comply with NFPA 10, "PortableFire Extinguishers."

B. Fire Extinguishers: Listed and labeled for type, rating, and classification by an independent testing agency acceptable to authorities having jurisdiction.

2.2 PORTABLE, HAND-CARRIED FIRE EXTINGUISHERS

A. Fire Extinguishers: Type, size, and capacity for each [fire-protection cabinet] [and] [mountingbracket] indicated.

1. Manufacturers: Subject to compliance with requirements, [provide products by the following] [provide products by one of the following] [available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following]:

2. Basis-of-Design Product: Subject to compliance with requirements, provide [productindicated on Drawings] <Insert manufacturer's name; product name or designation> or comparable product by one of the following:

a. Amerex Corporation.

b. Ansul Incorporated.

c. Badger Fire Protection.

d. Buckeye Fire Equipment Company.

e. Fire End & Croker Corporation.

f. Guardian Fire Equipment, Inc.

g. JL Industries, Inc.; a division of the Activar Construction Products Group.

h. Kidde Residential and Commercial Division; Subsidiary of Kidde plc.

i. Larsens Manufacturing Company.

j. Moon American.

k. Nystrom Building Products.

l. Pem All Fire Extinguisher Corp.

m. Potter Roemer LLC.

n. Pyro-Chem; Tyco Safety Products.

Page 15: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

FIRE EXTINGUISHERS 104416Caron Architecture LLC © 2014

o. Strike First Corporation of America.

p. <Insert manufacturer's name>.

3. Instruction Labels: Include pictorial marking system complying with NFPA 10,Appendix B[, and bar coding for documenting fire-extinguisher location, inspections, maintenance, and recharging].

B. Stored-Pressure Water Type <Insert drawing designation>: UL-rated 2-A, 2.5-gal. (9.5-L)nominal capacity, with water in stainless-steel container; with pressure-indicating gage.

C. Stored-Pressure Antifreeze Water Type <Insert drawing designation>: UL-rated 2-A, 2.5-gal.(9.5-L) nominal capacity, with water and approved antifreeze solution mixed for temperatures as low as minus 40 deg F (minus 40 deg C) in stainless-steel container; with pressure-indicatinggage.

D. Stored-Pressure Water-Mist Type <Insert drawing designation>: UL-rated 2-A:C, 2.5-gal. (9.5-L) nominal capacity, with water in enameled-steel container; with pressure-indicating gage.

E. Regular Dry-Chemical Type <Insert drawing designation>: UL-rated <Insert capacity> nominal capacity, with sodium bicarbonate-based dry chemical in manufacturer's standard enameled container.

F. Multipurpose Dry-Chemical Type <Insert drawing designation>: UL-rated <Insert capacity>nominal capacity, with monoammonium phosphate-based dry chemical in manufacturer's standard enameled container.

G. Carbon Dioxide Type <Insert drawing designation>: UL-rated [5-B:C, 5-lb (2.3-kg)] [10-B:C, 10-lb (4.5-kg)] [10-B:C, 15-lb (6.8-kg)] [10-B:C, 20-lb (9.1-kg)] nominal capacity, with carbon dioxide in manufacturer's standard enameled-metal container.

H. Clean-Agent Type in Steel Container <Insert drawing designation>: UL-rated [5-B:C, 4.75-lb(2.2-kg)] [1-A:10-B:C, 10-lb (4.5-kg)] [2-A:10-B:C, 14-lb (6.4-kg)] nominal capacity, with HFC blend agent and inert material in enameled-steel container; with pressure-indicating gage.

2.3 MOUNTING BRACKETS <Insert drawing designation>

A. Mounting Brackets: Manufacturer's standard[ galvanized] steel, designed to secure fire extinguisher to wall or structure, of sizes required for types and capacities of fire extinguishersindicated, with plated or [red] [black] baked-enamel finish.

1. Manufacturers: Subject to compliance with requirements, [provide products by the following] [provide products by one of the following] [available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following]:

2. Basis-of-Design Product: Subject to compliance with requirements, provide [productindicated on Drawings] <Insert manufacturer's name; product name or designation> or comparable product by one of the following:

Page 16: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

FIRE EXTINGUISHERS 104416Caron Architecture LLC © 2014

a. Amerex Corporation.

b. Ansul Incorporated.

c. Badger Fire Protection.

d. Buckeye Fire Equipment Company.

e. Fire End & Croker Corporation.

f. Guardian Fire Equipment, Inc.

g. JL Industries, Inc.; a division of the Activar Construction Products Group.

h. Larsens Manufacturing Company.

i. Nystrom Building Products.

j. Potter Roemer LLC.

k. Strike First Corporation of America.

l. <Insert manufacturer's name>.

B. Identification: Lettering complying with authorities having jurisdiction for letter style, size, spacing, and location. Locate as indicated by Architect.

1. Identify bracket-mounted fire extinguishers with the words "FIRE EXTINGUISHER" in red letter decals applied to mounting surface.

a. Orientation: [Vertical] [Horizontal].

PART 3 - EXECUTION

3.1 INSTALLATION

A. Examine fire extinguishers for proper charging and tagging.

1. Remove and replace damaged, defective, or undercharged fire extinguishers.

B. Install fire extinguishers[ and mounting brackets] in locations indicated and in compliance with requirements of authorities having jurisdiction.

1. Mounting Brackets: [54 inches (1372 mm)] <Insert dimension> above finished floor to top of fire extinguisher.

C. Mounting Brackets: Fasten mounting brackets to surfaces, square and plumb, at locations indicated.

Page 17: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

FIRE EXTINGUISHERS 104416Caron Architecture LLC © 2014

END OF SECTION 104416

Page 18: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

METAL LOCKERS 105113Caron Architecture LLC © 2014

SECTION 105113 - METAL LOCKERSTIPS:To view non-printing Editor's Notes that provide guidance for editing, click on Masterworks/Single-FileFormatting/Toggle/Editor's Notes.To read detailed research, technical information about products and materials, and coordination checklists, click on Masterworks/Supporting Information.

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Knocked-down corridor lockers.2. Welded corridor lockers.3. Knocked-down athletic lockers.4. Welded athletic lockers.5. Locker benches.

1.2 ACTION SUBMITTALS

A. Product data.

B. LEED Submittals:

1. Product Data for Credit IEQ 4.4: For composite wood products used in lockers, documentation indicating that product contains no urea formaldehyde.

C. Shop Drawings: Include plans, elevations, sections, details, attachments to other work, and locker identification system and numbering sequence.

D. Samples: For each color specified.

1.3 INFORMATIONAL SUBMITTALS

A. Sample warranties.

1.4 CLOSEOUT SUBMITTALS

A. Maintenance data.

Page 19: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

METAL LOCKERS 105113Caron Architecture LLC © 2014

1.5 WARRANTY

A. Special Warranty: Manufacturer agrees to repair or replace components of metal lockers that fail in materials or workmanship, excluding finish, within specified warranty period.

1. Warranty Period for Knocked-Down Metal Lockers: [Two] <Insert number> years from date of Substantial Completion.

2. Warranty Period for Welded Metal Lockers: [Lifetime] [10 years] <Insert years> from date of Substantial Completion.

PART 2 - PRODUCTS

2.1 PERFORMANCE REQUIREMENTS

A. Accessibility Requirements: For lockers indicated to be accessible, comply with applicable provisions in [the U.S. Architectural & Transportation Barriers Compliance Board's ADA-ABAAccessibility Guidelines] [and] [ICC A117.1].

2.2 KNOCKED-DOWN CORRIDOR LOCKERS <Insert designation>

A. Products: Subject to compliance with requirements, [provide the following] [provide one of the following] [available products that may be incorporated into the Work include, but are not limited to, the following]:

1. Art Metal Products; [Artisan Quiet K.D.] [Heavy-Duty Corridor] [Heavy-Duty Corridor Elite] [Magnum Student K.D.] [Standard K.D.] [Standard Quiet].

2. ASI Storage Solutions Inc; [Traditional] [Traditional Plus].

3. DeBourgh Mfg. Co; Worley SAT Knock Down.

4. General Storage Systems Ltd; [Decor Tri-Lok Corona] [Decor Tri-Lok Eclipse] [Decor Tri-Lok Eclipse II] [Decor Tri-Lok Smart Line] [Decor Tri-Lok Titan] [Decor Tri-Lok Titan II].

5. Hadrian Manufacturing, Inc; Emperor.

6. List Industries Inc; [Classic Superior KD] [Heavy Duty Corridor] [Heavy Duty Corridor Deluxe] [Heavy Duty Corridor Premier] [Marquis Student KD] [Standard Quiet KD][Whisper Quiet].

7. Lyon Workspace Products, LLC; [Standard] [Heavy Duty].

8. Olympus Lockers & Storage Products, Inc; [Standard KD] [Heavy Duty Corridor][Athena].

9. Penco Products, Inc; [Guardian] [Guardian Plus] [Guardian Medallion] [Vanguard].

Page 20: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

METAL LOCKERS 105113Caron Architecture LLC © 2014

10. Republic Storage Systems Company; [Heavy Duty Corridor] [Quiet] [Single Point II Corridor] [Standard].

11. Shanahan's Limited; [Archette] [Deluxe-16] [Deluxe-20].

12. <Insert manufacturer's name; product name or designation>.

B. Basis-of-Design Product: Subject to compliance with requirements, provide [product indicatedon Drawings] <Insert manufacturer's name; product name or designation> or comparable product by one of the following:

1. <Insert manufacturer's name>.

C. Doors: One piece; fabricated from [0.060-inch (1.52-mm)] [0.075-inch (1.90-mm)] nominal-thickness steel sheet; formed into channel shape with double bend at vertical edges and with right-angle single bend at horizontal edges.

1. Doors less than 12 inches (305 mm) wide may be fabricated from 0.048-inch (1.21-mm)nominal-thickness steel sheet.

2. Doors for box lockers less than 15 inches (381 mm) wide may be fabricated from 0.048-inch (1.21-mm) nominal-thickness steel sheet.

3. Reinforcement: Manufacturer's standard reinforcing angles, channels, or stiffeners for doors more than 15 inches (381 mm) wide; welded to inner face of doors.

4. Stiffeners: Manufacturer's standard full-height stiffener fabricated from 0.048-inch(1.21-mm) nominal-thickness steel sheet; welded to inner face of doors.

5. Door Style:[ Unperforated panel.][ Vented panel as follows:]

a. Louvered Vents: No fewer than [six louver openings at top and bottom for single-tier] [three louver openings at top and bottom for double-tier] [twolouver openings at top and bottom, or three louver openings at top or bottom, for triple-tier] <Insert configuration> lockers.

b. Perforated Vents: [Manufacturer's standard shape and configuration] <Insertshape and configuration>.

c. Concealed Vents: Slotted perforations in top and bottom horizontal door return flanges.

D. Body: Assembled by riveting or bolting body components together. Fabricate from unperforated steel sheet with thicknesses as follows:

1. Tops, Bottoms, and Intermediate Dividers: 0.024-inch (0.61-mm) nominal thickness, with single bend at sides.

2. Backs and Sides: 0.024-inch (0.61-mm) nominal thickness, with full-height, double-flanged connections.

3. Shelves: 0.024-inch (0.61-mm)nominal thickness, with double bend at front and single bend at sides and back.

E. Frames: Channel formed; fabricated from 0.060-inch (1.52-mm) nominal-thickness steel sheet;lapped and factory welded at corners; with top and bottom main frames factory welded into

Page 21: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

METAL LOCKERS 105113Caron Architecture LLC © 2014

vertical main frames. Form continuous, integral, full-height door strikes on vertical main frames.

F. Hinges:

1. Knuckle Hinges: Steel, full loop, five or seven knuckles, tight pin; minimum 2 inches (51mm) high. Provide no fewer than three hinges for each door more than 42 inches (1067mm) high.

2. Continuous Hinges: Manufacturer's standard, steel, full height.3. Hinges: Manufacturer's standard, steel, continuous or knuckle type.

G. Projecting Door Handle and Latch: Finger-lift latch control designed for use with either built-incombination locks or padlocks; positive automatic latching, chromium plated; pry and vandal resistant.

1. Latch Hooks: Equip doors 48 inches (1219 mm) and higher with three latch hooks and doors less than 48 inches (1219 mm) high with two latch hooks; fabricated from 0.105-inch (2.66-mm) nominal-thickness steel sheet; welded or riveted to full-height door strikes; with resilient silencer on each latch hook.

2. Latching Mechanism: Manufacturer's standard, rattle-free latching mechanism and moving components isolated to prevent metal-to-metal contact, and incorporating a prelocking device that allows locker door to be locked while door is open and then closed without unlocking or damaging lock or latching mechanism.

H. Recessed Door Handle and Latch: Stainless-steel cup with integral door pull, recessed so locking device does not protrude beyond door face; pry and vandal resistant.

1. Multipoint Latching: Finger-lift latch control designed for use with built-in combination locks, built-in key locks, or padlocks; positive automatic latching and prelocking.

a. Latch Hooks: Equip doors 48 inches (1219 mm) and higher with three latch hooks and doors less than 48 inches (1219 mm) high with two latch hooks; fabricated from 0.105-inch (2.66-mm) nominal-thickness steel sheet; welded or riveted to full-height door strikes; with resilient silencer on each latch hook.

b. Latching Mechanism: Manufacturer's standard, rattle-free latching mechanism.

2. Single-Point Latching: Nonmoving latch hook [designed to engage bolt of built-incombination or cylinder lock] [with steel padlock loop that projects through recessed cup and is finished to match metal locker body]. Equip each door with one latch hook.

I. Door Handle and Latch for [Box] [16-Person] Lockers: Stainless-steel strike plate with integral pull; with steel padlock loop that projects through metal locker door.

J. Locks: [Combination padlocks] [Built-in combination locks] [Cylinder locks] [Built-in, card-operated locks] [Digital keypad locks].

K. Identification Plates: Manufacturer's standard, etched, embossed, or stamped [aluminum][plastic] plates, with numbers and letters at least 3/8 inch (9 mm) high.

Page 22: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

METAL LOCKERS 105113Caron Architecture LLC © 2014

L. Hooks: Manufacturer's standard ball-pointed type hooks, aluminum or steel; zinc plated.

M. Coat Rods: Manufacturer's standard.

N. Legs: [6 inches (152 mm)] <Insert dimension> high; formed by extending vertical frame members, or fabricated from 0.075-inch (1.90-mm) nominal-thickness steel sheet; welded to bottom of locker[ with closed front and end bases].

O. Continuous Zee Base: Fabricated from [0.060-inch (1.52-mm)] [0.075-inch (1.90-mm)][manufacturer's standard thickness, but not less than 0.060-inch (1.52-mm)] nominal-thickness steel sheet.

1. Height: [4 inches (102 mm)] <Insert dimension>.

P. Continuous Sloping Tops: Fabricated from [0.036-inch (0.91-mm)] [0.048-inch (1.21-mm)][manufacturer's standard thickness, but not less than 0.036-inch (0.91-mm)] nominal-thickness steel sheet.

1. Closures: [Vertical] [Hipped]-end type.

Q. Individual Sloping Tops: Fabricated from 0.024-inch (0.61-mm) nominal-thickness steel sheet.

R. Recess Trim: Fabricated from 0.048-inch (1.21-mm) nominal-thickness steel sheet.

S. Filler Panels: Fabricated from [0.036-inch (0.91-mm)] [0.048-inch (1.21-mm)] [manufacturer's standard thickness, but not less than 0.036-inch (0.91-mm)] nominal-thickness steel sheet.

T. Boxed End Panels: Fabricated from 0.060-inch (1.52-mm) nominal-thickness steel sheet.

U. Finished End Panels: Fabricated from 0.024-inch (0.61-mm) nominal-thickness steel sheet.

V. Center Dividers: Fabricated from 0.024-inch (0.61-mm) nominal-thickness steel sheet.

W. Materials:

1. Cold-Rolled Steel Sheet: ASTM A 1008/A 1008M, Commercial Steel (CS), Type B, suitable for exposed applications.

2. Metallic-Coated Steel Sheet: ASTM A 653/A 653M, Commercial Steel (CS), Type B; withA60 (ZF180) zinc-iron, alloy (galvannealed) coating designation.

X. Finish: Baked enamel or powder coat.

1. Color: [As indicated by manufacturer's designations] [Match Architect's sample] [Asselected by Architect from manufacturer's full range] <Insert color>.

Page 23: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

METAL LOCKERS 105113Caron Architecture LLC © 2014

2.3 WELDED CORRIDOR LOCKERS <Insert designation>

A. Products: Subject to compliance with requirements, [provide the following] [provide one of the following] [available products that may be incorporated into the Work include, but are not limited to, the following]:

1. Art Metal Products; [Bulldog Corridor] [Champ Corridor] [Champ Corridor Elite].

2. DeBourgh Mfg. Co; Angle Iron Corridor.

3. List Industries Inc; [Booksafe III] [Classmate] [Classmate Premier] [Graduate] [GraduatePremier] [Marquis Protector].

4. Lyon Workspace Products, LLC; [All-Welded] [Integrated Frame].

5. Olympus Lockers & Storage Products, Inc; Hercules.

6. Penco Products, Inc; [All-Welded] [All-Welded Defiant].

7. Republic Storage Systems Company; [All-Welded Ventilated] [Single Point II Corridor][Ultra-Frame].

8. <Insert manufacturer's name; product name or designation>.

B. Basis-of-Design Product: Subject to compliance with requirements, provide [product indicated on Drawings] <Insert manufacturer's name; product name or designation> or comparable product by one of the following:

1. <Insert manufacturer's name>.

C. Doors: One piece; fabricated from 0.075-inch (1.90-mm) nominal-thickness steel sheet; formed into channel shape with double bend at vertical edges and with right-angle single bend at horizontal edges.

1. Reinforcement: Manufacturer's standard reinforcing angles, channels, or stiffeners for doors more than 15 inches (381 mm) wide; welded to inner face of doors.

2. Door Style:[ Unperforated panel.][ Vented panel as follows:]

a. Louvered Vents: No fewer than [six louver openings at top and bottom for single-tier] [three louver openings at top and bottom for double-tier] [twolouver openings at top and bottom, or three louver openings at top or bottom, for triple-tier] <Insert configuration> lockers.

b. Perforated Vents: [Manufacturer's standard shape and configuration] <Insertshape and configuration>.

D. Body: Assembled by welding body components together. Fabricate from unperforated steel sheet with thicknesses as follows:

1. Tops, Bottoms, and Sides: 0.060-inch (1.52-mm) nominal thickness.

Page 24: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

METAL LOCKERS 105113Caron Architecture LLC © 2014

2. Backs: 0.048-inch (1.21-mm) nominal thickness.3. Shelves: 0.060-inch (1.52-mm) nominal thickness, with double bend at front and single

bend at sides and back.

E. Frames: Channel formed; fabricated from 0.060-inch (1.52-mm) nominal-thickness steel sheet; lapped and factory welded at corners; with top and bottom main frames factory welded intovertical main frames. Form continuous, integral, full-height door strikes on vertical main frames.

F. Hinges:

1. Knuckle Hinges: Steel, full loop, five or seven knuckles, tight pin; minimum 2 inches (51mm) high. Provide no fewer than three hinges for each door more than 42 inches (1067mm) high.

2. Continuous Hinges: Manufacturer's standard, steel, full height.3. Hinges: Manufacturer's standard, steel, continuous or knuckle type.

G. Projecting Door Handle and Latch: Finger-lift latch control designed for use with either built-incombination locks or padlocks; positive automatic latching, chromium plated; pry and vandal resistant.

1. Latch Hooks: Equip doors 48 inches (1219 mm) and higher with three latch hooks and doors less than 48 inches (1219 mm) high with two latch hooks; fabricated from 0.105-inch (2.66-mm) nominal-thickness steel sheet; welded or riveted to full-height door strikes; with resilient silencer on each latch hook.

2. Latching Mechanism: Manufacturer's standard, rattle-free latching mechanism and moving components isolated to prevent metal-to-metal contact, and incorporating a prelocking device that allows locker door to be locked while door is open and then closed without unlocking or damaging lock or latching mechanism.

H. Recessed Door Handle and Latch: Stainless-steel cup with integral door pull, recessed so locking device does not protrude beyond door face; pry and vandal resistant.

1. Multipoint Latching: Finger-lift latch control designed for use with built-in combination locks or padlocks; positive automatic latching and prelocking.

a. Latch Hooks: Equip doors 48 inches (1219 mm) and higher with three latch hooks and doors less than 48 inches (1219 mm) high with two latch hooks; fabricated from 0.120-inch (3.04-mm) nominal-thickness steel sheet; welded to full-heightdoor strikes; with resilient silencer on each latch hook.

b. Latching Mechanism: Manufacturer's standard, rattle-free latching mechanism.

2. Single-Point Latching: Nonmoving latch hook [designed to engage bolt of built-incombination or cylinder lock] [with steel padlock loop that projects through recessed cup and is finished to match metal locker body]. Equip each door with one latch hook.

I. Door Handle and Latch for [Box] [16-Person] Lockers: Stainless-steel strike plate with integral pull; with steel padlock loop that projects through metal locker door.

Page 25: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

METAL LOCKERS 105113Caron Architecture LLC © 2014

J. Locks: [Combination padlocks] [Built-in combination locks] [Cylinder locks] [Built-in, card-operated locks] [Digital keypad locks].

K. Identification Plates: Manufacturer's standard, etched, embossed, or stamped [aluminum][plastic] plates, with numbers and letters at least 3/8 inch (9 mm) high.

L. Hooks: Manufacturer's standard ball-pointed type, aluminum or steel; zinc plated.

M. Coat Rods: Manufacturer's standard.

N. Legs: [6 inches (152 mm)] <Insert dimension> high; formed by extending vertical frame members, or fabricated from 0.075-inch (1.90-mm) nominal-thickness steel sheet; welded to bottom of locker[ with closed front and end bases].

O. Continuous Zee Base: Fabricated from, [0.060-inch (1.52-mm)] [0.075-inch (1.90-mm)][manufacturer's standard thickness, but not less than 0.060-inch (1.52-mm)] nominal-thickness steel sheet.

1. Height: [4 inches (102 mm)] <Insert dimension>.

P. Continuous Sloping Tops: Fabricated from 0.048-inch (1.21-mm) nominal-thickness steel sheet, with a pitch of approximately 20 degrees.

1. Closures: [Vertical] [Hipped]-end type.

Q. Recess Trim: Fabricated from 0.048-inch (1.21-mm) nominal-thickness steel sheet.

R. Filler Panels: Fabricated from 0.048-inch (1.21-mm) nominal-thickness steel sheet.

S. Boxed End Panels: Fabricated from 0.048-inch (1.21-mm) nominal-thickness steel sheet.

T. Materials:

1. Cold-Rolled Steel Sheet: ASTM A 1008/A 1008M, Commercial Steel (CS), Type B, suitable for exposed applications.

2. Metallic-Coated Steel Sheet: ASTM A 653/A 653M, Commercial Steel (CS), Type B; with A60 (ZF180) zinc-iron, alloy (galvannealed) coating designation.

U. Finish: Baked enamel or powder coat.

1. Color: [As indicated by manufacturer's designations] [Match Architect's sample] [Asselected by Architect from manufacturer's full range] <Insert color>.

2.4 KNOCKED-DOWN ATHLETIC LOCKERS <Insert designation>

A. Products: Subject to compliance with requirements, [provide the following] [provide one of the following] [available products that may be incorporated into the Work include, but are not limited to, the following]:

Page 26: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

METAL LOCKERS 105113Caron Architecture LLC © 2014

1. Art Metal Products; [HDV] [HDV Magnum] [HDV Elite].

2. ASI Storage Solutions Inc; Competitor.

3. DeBourgh Mfg. Co; Knock Down Athletic.

4. General Storage Systems Ltd; [Mod-U-Vent] [Mod-U-Vent II].

5. Hadrian Manufacturing Inc; Gladiator.

6. List Industries Inc; [HDV] [HDV Premier] [HDV Marquis Student].

7. Lyon Workspace Products, LLC; [Knocked Down Expanded Metal] [Heavy Duty Ventilated].

8. Olympus Lockers & Storage Products, Inc; [Basic HDV Lockers] [Apollo HDV Lockers].

9. Penco Products, Inc; Invincible II.

10. Republic Storage Systems Company; [Heavy Duty Ventilated] [Single Point II Athletic].

11. Shanahan's Manufacturing Limited; [Pinnacle] [Apex] [Summit].

12. <Insert manufacturer's name; product name or designation>.

B. Basis-of-Design Product: Subject to compliance with requirements, provide [product indicated on Drawings] <Insert manufacturer's name; product name or designation> or comparable product by one of the following:

1. <Insert manufacturer's name>.

C. Perforated Doors: One piece; fabricated from 0.075-inch (1.90-mm) nominal-thickness steel sheet with manufacturer's standard diamond perforations; formed into channel shape with double bend at [vertical edges and with right-angle single bend at horizontal edges] [and][latch point (bottom) and right-angle single bend at remaining edges for box lockers].

1. Reinforcement: Manufacturer's standard reinforcing angles, channels, or stiffeners for doors more than 15 inches (381 mm) wide; welded to inner face of doors.

D. Expanded-Metal Doors: Fabricated from 0.090-inch (2.28-mm) nominal-thickness expanded metal; welded to 0.105-inch (2.66-mm) nominal-thickness steel angle frame; with 0.090-inch(2.28-mm) nominal-thickness, steel sheet lock panel backed by 0.060-inch (1.52-mm) nominal-thickness, steel sheet retainer welded to door frame.

E. Body: Assembled by riveting or bolting body components together. Fabricate from unperforated steel sheet with thicknesses as follows:

1. Tops and Bottoms: 0.060-inch (1.52-mm) nominal thickness, with single bend at edges.2. Backs: 0.048-inch (1.21-mm) nominal thickness.

Page 27: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

METAL LOCKERS 105113Caron Architecture LLC © 2014

3. Shelves: 0.060-inch (1.52-mm) nominal thickness, with double bend at front and single bend at sides and back.

F. Unperforated Sides: Fabricated from [0.048-inch (1.21-mm)] [0.060-inch (1.52-mm)] nominal-thickness steel sheet.

G. Perforated Sides: Fabricated from 0.060-inch (1.52-mm) nominal-thickness steel sheet with manufacturer's standard diamond perforations.

H. Expanded-Metal Sides: Fabricated from 0.090-inch (2.28-mm) nominal-thickness expanded metal; welded to 0.105-inch (2.66-mm) nominal-thickness steel angles or 0.060-inch (1.52-mm) nominal-thickness steel channel frames.

I. Frames: Channel formed; fabricated from 0.060-inch (1.52-mm) nominal-thickness steel sheet or 0.097-inch (2.45-mm) nominal-thickness steel angles; lapped and factory welded at corners; with top and bottom main frames factory welded into vertical main frames. Form continuous, integral, full-height door strikes on vertical main frames.

J. Reinforced Bottoms: Structural channels, formed from [0.060-inch (1.52-mm)] [0.075-inch(1.90-mm)] nominal-thickness steel sheet; welded to front and rear of side-panel frames.

K. Hinges:

1. Knuckle Hinges: Steel, full loop, five or seven knuckles, tight pin; minimum 2 inches (51mm) high. Provide no fewer than three hinges for each door more than 42 inches (1067mm) high.

2. Continuous Hinges: Manufacturer's standard, steel; side or top mounted as required by locker configuration.

3. Hinges: Manufacturer's standard, steel, continuous or knuckle type.

L. Recessed Door Handle and Latch: Stainless-steel cup with integral door pull, recessed so locking device does not protrude beyond door face; pry and vandal resistant.

1. Multipoint Latching: Finger-lift latch control designed for use with built-in combination locks, built-in cylinder locks, or padlocks; positive automatic latching and prelocking.

a. Latch Hooks: Equip doors 48 inches (1219 mm) and higher with three latch hooks and doors less than 48 inches (1219 mm) high with two latch hooks; fabricated from 0.120-inch (3.04-mm) nominal-thickness steel sheet; welded to full-heightdoor strikes; with resilient silencer on each latch hook.

b. Latching Mechanism: Manufacturer's standard, rattle-free latching mechanism.

2. Single-Point Latching: Nonmoving latch hook [designed to engage bolt of built-incombination or cylinder lock] [with steel padlock loop that projects through recessed cup and is finished to match metal locker body].

a. Latch Hook: Equip each door with one latch hook, fabricated from 0.120-inch(3.04-mm) nominal-thickness steel sheet; welded midway up full-height door strike; with resilient silencer.

Page 28: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

METAL LOCKERS 105113Caron Architecture LLC © 2014

M. Projecting Turn-Handle and Latch: Steel handle welded to manufacturer's standard, three-point, cremone-type latching mechanism consisting of steel rods or bars that engage locker frame at top and bottom of door, and center latch that engages strike jamb; with steel padlock loop.

N. Door Handle and Latch for Box Lockers: Stainless-steel strike plate with integral pull; with steel padlock loop that projects through metal locker door.

O. Locks: [Combination padlocks] [Built-in combination locks] [Cylinder locks] [Built-in, card-operated locks] [Digital keypad locks].

P. Identification Plates: Manufacturer's standard, etched, embossed, or stamped [aluminum][plastic] plates, with numbers and letters at least 3/8 inch (9 mm) high.

Q. Hooks: Manufacturer's standard ball-pointed type, aluminum or steel; zinc plated.

R. Coat Rods: Manufacturer's standard.

S. Legs: [6 inches (152 mm)] <Insert dimension> high; formed by extending vertical frame members, or fabricated from 0.075-inch (1.90-mm) nominal-thickness steel sheet; welded to bottom of locker[ with closed front and end bases].

T. Continuous Zee Base: 4 inches (102 mm) high; fabricated from 0.075-inch (1.90-mm) nominal-thickness steel sheet.

U. Continuous Sloping Tops: Fabricated from 0.048-inch (1.21-mm) nominal-thickness steel sheet, with a pitch of approximately 20 degrees.

1. Closures: [Vertical] [Hipped]-end type.

V. Recess Trim: Fabricated from 0.048-inch (1.21-mm) nominal-thickness steel sheet.

W. Filler Panels: Fabricated from 0.048-inch (1.21-mm) nominal-thickness steel sheet.

X. Boxed End Panels: Fabricated from 0.060-inch (1.52-mm) nominal-thickness steel sheet.

Y. Materials:

1. Cold-Rolled Steel Sheet: ASTM A 1008/A 1008M, Commercial Steel (CS), Type B, suitable for exposed applications.

2. Metallic-Coated Steel Sheet: ASTM A 653/A 653M, Commercial Steel (CS), Type B; with A60 (ZF180) zinc-iron, alloy (galvannealed) coating designation.

3. Expanded Metal: ASTM F 1267, Type II (flattened), Class I, 3/4-inch (19-mm) steel mesh, with at least 70 percent open area.

Z. Finish: Baked enamel or powder coat.

1. Color: [As indicated by manufacturer's designations] [Match Architect's sample] [Asselected by Architect from manufacturer's full range] <Insert color>.

Page 29: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

METAL LOCKERS 105113Caron Architecture LLC © 2014

2.5 WELDED ATHLETIC LOCKERS <Insert designation>

A. Products: Subject to compliance with requirements, [provide the following] [provide one of the following] [available products that may be incorporated into the Work include, but are not limited to, the following]:

1. Art Metal Products; [Athletic Box] [Bulldog Athletic] [Champ Athletic] [Turn-HandleAthletic] [Champ Athletic Elite] [Turn-Handle Athletic Elite].

2. DeBourgh Mfg. Co; [All-American P.E.] [Corregidor Team].

3. List Industries Inc; [Team] [Marquis Champion] [P.E.].

4. Lyon Workspace Products, LLC; [All-Welded Expanded Metal] [Angle Iron].

5. Olympus Lockers & Storage Products, Inc; Zeus.

6. Penco Products, Inc; [All-Welded] [All-Welded Defiant] [Angle Iron] [Pro Tough] [ProTough Defiant].

7. Republic Storage Systems Company; [All-Welded Ventilated] [Single-Point II Athletic][Ultra-Frame].

8. <Insert manufacturer's name; product name or designation>.

B. Basis-of-Design Product: Subject to compliance with requirements, provide [product indicated on Drawings] <Insert manufacturer's name; product name or designation> or comparable product by one of the following:

1. <Insert manufacturer's name>.

C. Perforated Doors: One piece; fabricated from 0.075-inch (1.90-mm) nominal-thickness steel sheet with manufacturer's standard diamond perforations; formed into channel shape with double bend at [vertical edges and with right-angle single bend at horizontal edges] [and][latch point (bottom) and right-angle single bend at remaining edges for box lockers].

1. Reinforcement: Manufacturer's standard reinforcing angles, channels, or stiffeners for doors more than 15 inches (381 mm) wide; welded to inner face of doors.

D. Expanded-Metal Doors: Fabricated from 0.090-inch (2.28-mm) nominal-thickness expanded metal; welded to 0.105-inch (2.66-mm) nominal-thickness steel angle frame; with 0.090-inch(2.28-mm) nominal-thickness, steel sheet lock panel backed by 0.060-inch (1.52-mm) nominal-thickness, steel sheet retainer welded to door frame.

E. Body: Assembled by welding body components together. Fabricate from unperforated steel sheet with thicknesses as follows:

1. Tops and Bottoms: 0.060-inch (1.52-mm) nominal thickness, with single bend at edges.2. Backs: 0.048-inch (1.21-mm) nominal thickness.

Page 30: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

METAL LOCKERS 105113Caron Architecture LLC © 2014

3. Shelves: 0.060-inch (1.52-mm) nominal thickness, with double bend at front and singlebend at sides and back.

F. Unperforated Sides: Fabricated from [0.048-inch (1.21-mm)] [0.060-inch (1.52-mm)] nominal-thickness steel sheet.

G. Perforated Sides: Fabricated from 0.060-inch (1.52-mm) nominal-thickness steel sheet with manufacturer's standard diamond perforations.

H. Expanded-Metal Sides: Fabricated from 0.090-inch (2.28-mm) nominal-thickness expanded metal; welded to 0.105-inch (2.66-mm) nominal-thickness steel angles or 0.060-inch (1.52-mm) nominal-thickness steel channel frames.

I. Frames: Channel formed; fabricated from 0.060-inch (1.52-mm) nominal-thickness steel sheet or 0.097-inch (2.45-mm) nominal-thickness steel angles; lapped and factory welded at corners;with top and bottom main frames factory welded into vertical main frames. Form continuous, integral, full-height door strikes on vertical main frames.

J. Reinforced Bottoms: Structural channels, formed from [0.060-inch (1.52-mm)] [0.075-inch(1.90-mm)] nominal-thickness steel sheet; welded to front and rear of side-panel frames.

K. Hinges:

1. Knuckle Hinges: Steel, full loop, five or seven knuckles, tight pin; minimum 2 inches (51mm) high. Provide no fewer than three hinges for each door more than 42 inches (1067mm) high.

2. Continuous Hinges: Manufacturer's standard, steel; side or top mounted as required by locker configuration.

3. Hinges: Manufacturer's standard, steel, continuous or knuckle type.

L. Recessed Door Handle and Latch: Stainless-steel cup with integral door pull, recessed so locking device does not protrude beyond door face; pry and vandal resistant.

1. Multipoint Latching: Finger-lift latch control designed for use with built-in combinationlocks, built-in cylinder locks, or padlocks; positive automatic latching and prelocking.

a. Latch Hooks: Equip doors 48 inches (1219 mm) and higher with three latch hooks and doors less than 48 inches (1219 mm) high with two latch hooks; fabricatedfrom 0.120-inch (3.04-mm) nominal-thickness steel sheet; welded to full-heightdoor strikes; with resilient silencer on each latch hook.

b. Latching Mechanism: Manufacturer's standard, rattle-free latching mechanism.

2. Single-Point Latching: Nonmoving latch hook [designed to engage bolt of built-incombination or cylinder lock] [with steel padlock loop that projects through recessed cup and is finished to match metal locker body].

a. Latch Hook: Equip each door with one latch hook, fabricated from 0.120-inch(3.04-mm) nominal-thickness steel sheet; welded midway up full-height door strike; with resilient silencer.

Page 31: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

METAL LOCKERS 105113Caron Architecture LLC © 2014

M. Projecting Turn-Handle and Latch: Steel handle welded to manufacturer's standard, three-point, cremone-type latching mechanism consisting of steel rods or bars that engage locker frame at top and bottom of door, and center latch that engages strike jamb; with steel padlock loop.

N. Door Handle and Latch for Box Lockers: Stainless-steel strike plate with integral pull; with steel padlock loop that projects through metal locker door.

O. Locks: [Combination padlocks] [Built-in combination locks] [Cylinder locks] [Built-in, card-operated locks] [Digital keypad locks].

P. Identification Plates: Manufacturer's standard, etched, embossed, or stamped [aluminum][plastic] plates, with numbers and letters at least 3/8 inch (9 mm) high.

Q. Hooks: Manufacturer's standard ball-pointed type, aluminum or steel; zinc plated.

R. Coat Rods: Manufacturer's standard.

S. Legs: [6 inches (152 mm)] <Insert dimension> high; formed by extending vertical frame members, or fabricated from 0.075-inch (1.90-mm) nominal-thickness steel sheet; welded to bottom of locker[ with closed front and end bases].

T. Continuous Zee Base: 4 inches (102 mm) high; fabricated from 0.075-inch (1.90-mm) nominal-thickness steel sheet.

U. Continuous Sloping Tops: Fabricated from 0.048-inch (1.21-mm) nominal-thickness steel sheet, with a pitch of approximately 20 degrees.

1. Closures: [Vertical] [Hipped]-end type.

V. Recess Trim: Fabricated from 0.048-inch (1.21-mm) nominal-thickness steel sheet.

W. Filler Panels: Fabricated from 0.048-inch (1.21-mm) nominal-thickness steel sheet.

X. Boxed End Panels: Fabricated from 0.060-inch (1.52-mm) nominal-thickness steel sheet.

Y. Materials:

1. Cold-Rolled Steel Sheet: ASTM A 1008/A 1008M, Commercial Steel (CS), Type B, suitable for exposed applications.

2. Metallic-Coated Steel Sheet: ASTM A 653/A 653M, Commercial Steel (CS), Type B; withA60 (ZF180) zinc-iron, alloy (galvannealed) coating designation.

3. Expanded Metal: ASTM F 1267, Type II (flattened), Class I, 3/4-inch (19-mm) steel mesh, with at least 70 percent open area.

Z. Finish: Baked enamel or powder coat.

1. Color: [As indicated by manufacturer's designations] [Match Architect's sample] [Asselected by Architect from manufacturer's full range] <Insert color>.

Page 32: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

METAL LOCKERS 105113Caron Architecture LLC © 2014

2.6 LOCKS

A. Manufacturers: Subject to compliance with requirements, [provide products by the following][provide products by one of the following] [available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following]:

1. American Locker Company; A Division of Master Lock Company, LLC.

2. Master Lock Company, LLC.

3. Zephyr Lock LLC.

4. <Insert manufacturer's name>.

B. Basis-of-Design Product: Subject to compliance with requirements, provide [product indicated on Drawings] <Insert manufacturer's name; product name or designation> or comparable product by one of the following:

1. <Insert manufacturer's name>.

C. Combination Padlocks: [Key-controlled, three-number dialing combination locks; capable of five combination changes] [Provided by Owner].

D. Built-in Combination Locks: Key-controlled, three-number dialing combination locks; capable of at least five combination changes made automatically with a control key.

1. Bolt Operation: [Manually locking deadbolt] [or] [automatically locking spring bolt].

E. Cylinder Locks: Built-in, flush, cam locks with five-pin tumbler keyway, keyed separately and master keyed. Furnish two change keys for each lock and [two] <Insert number> master keys.

1. Key Type: [Flat] [Grooved][, with minimum 2- by 2.68-inch (51- by 68.3-mm) key head for accessible lockers].

2. Bolt Operation: [Manually locking deadbolt] [or] [automatically locking spring bolt].

F. Built-in, Card-Operated Locks: Self-contained units mounted on interior of door with replaceable lock cylinders keyed separately and master keyed. Mount instruction decals on both door faces. Furnish one change card key for each lock and one master card key.

1. Bolt Operation: [Manually locking deadbolt] [or] [automatically locking spring bolt].

G. Digital Keypad Locks: Battery-powered electronic keypad with reprogrammable manager and owner codes that override access. Three consecutive incorrect code entries shall disable lock for three minutes.

1. Designed for permanently assigned access via entry of user's four-digit code.2. Designed for shared or temporary access by multiple users, with user-defined code to

lock and unlock. Provide LED indicator to show when lock is in use.

Page 33: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

METAL LOCKERS 105113Caron Architecture LLC © 2014

2.7 LOCKER BENCHES

A. Provide bench units with overall assembly height of [17-1/2 inches (445 mm)] <Insertdimension>.

B. Bench Tops: Manufacturer's standard one-piece units, with rounded corners and edges.

1. Size: Minimum 9-1/2 inches wide by 1-1/4 inches thick (241 mm wide by 32 mm thick)[ except provide minimum 20-inch- (508-mm-) wide tops where accessible benches are indicated].

2. Laminated clear hardwood with one coat of clear sealer on all surfaces and one coat of clear lacquer on top and sides.

C. Fixed Pedestals: Manufacturer's standard tubular steel supports, with predrilled fastener holes for attaching bench top and anchoring to floor, complete with fasteners and anchors.

1. Color: [Match metal lockers] [As indicated by manufacturer's designations] [MatchArchitect's sample] [As selected by Architect from manufacturer's full range].

D. Freestanding Pedestals: Manufacturer's standard aluminum supports, with predrilled fastener holes for attaching bench top, complete with fasteners, and as follows:

1. Finish: [Clear] [Black] [Gold] anodic finish.

E. Materials:

1. Stainless Steel: ASTM A 666, Type 304.2. Steel Tube: ASTM A 500/A 500 M, cold rolled.3. Particleboard: ANSI A208.1, Grade M-2.

2.8 FABRICATION

A. Fabricate metal lockers square, rigid, without warp, and with metal faces flat and free of dents or distortion. Make exposed metal edges safe to touch and free of sharp edges and burrs.

B. Fabricate each metal locker with an individual door and frame; individual top, bottom, and back; and common intermediate uprights separating compartments. Factory weld frame members of each metal locker together to form a rigid, one-piece assembly.

C. Equipment: Provide each locker with an identification plate and the following equipment:

1. Single-Tier Units: Shelf, one double-prong ceiling hook, and two single-prong wall hooks.2. Double-Tier Units: One double-prong ceiling hook and two single-prong wall hooks.3. Triple-Tier Units: One double-prong ceiling hook.4. Coat Rods: [As indicated on Drawings] [For each compartment of each locker] [In lieu

of ceiling hook for metal lockers 24 inches (610 mm) high or more] [In lieu of ceiling hook for metal lockers 18 inches (457 mm) deep or more].

Page 34: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

METAL LOCKERS 105113Caron Architecture LLC © 2014

D. Knocked-Down Construction: Fabricate metal lockers using nuts, bolts, screws, or rivets for [nominal assembly at Project site] [preassembly at plant prior to shipping].

E. Welded Construction: Factory preassemble metal lockers by welding all joints, seams, and connections; with no bolts, nuts, screws, or rivets used in assembly of main locker groups.Factory weld main locker groups into one-piece structures. Grind exposed welds flush.

F. Accessible Lockers: Fabricate as follows:

1. Locate bottom shelf no lower than 15 inches (381 mm) above the floor.2. Where hooks, coat rods, or additional shelves are provided, locate no higher than 48

inches (1219 mm) above the floor.

G. Continuous Base: Formed into channel or zee profile for stiffness, and fabricated in lengths as long as practical to enclose base and base ends of metal lockers; finished to match lockers.

H. Continuous Sloping Tops: Fabricated in lengths as long as practical, without visible fasteners at splice locations; finished to match lockers.

I. Individual Sloping Tops: Fabricated in width to fit one locker frame in lieu of flat locker tops; with integral back; finished to match lockers. Provide wedge-shaped divider panels between lockers.

J. Recess Trim: Fabricated with minimum 2-1/2-inch (64-mm) face width and in lengths as long as practical; finished to match lockers.

K. Filler Panels: Fabricated in an unequal leg angle shape; finished to match lockers. Provide slip-joint filler angle formed to receive filler panel.

L. Boxed End Panels: Fabricated with 1-inch- (25-mm-) wide edge dimension, and designed for concealing fasteners and holes at exposed ends of nonrecessed metal lockers; finished to match lockers.

M. Finished End Panels: Designed for concealing unused penetrations and fasteners, except for perimeter fasteners, at exposed ends of nonrecessed metal lockers; finished to match lockers.

N. Center Dividers: Full-depth, vertical partitions between bottom and shelf; finished to match lockers.

PART 3 - EXECUTION

3.1 INSTALLATION

A. General: Install lockers level, plumb, and true; shim as required, using concealed shims.

Page 35: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

METAL LOCKERS 105113Caron Architecture LLC © 2014

1. Anchor locker runs at ends and at intervals recommended by manufacturer, but not more than 36 inches (910 mm) o.c. Using concealed fasteners, install anchors through backup reinforcing plates, channels, or blocking as required to prevent metal distortion.

2. Anchor single rows of metal lockers to walls near top [and bottom of lockers] [oflockers and to floor].

3. Anchor back-to-back metal lockers to floor.

B. Knocked-Down Lockers: Assemble with standard fasteners, with no exposed fasteners on door faces or face frames.

C. Welded Lockers: Connect groups together with standard fasteners, with no exposed fasteners on face frames.

D. Trim: Fit exposed connections of trim, fillers, and closures accurately together to form tight, hairline joints, with concealed fasteners and splice plates.

1. Attach recess trim to recessed metal lockers with concealed clips.2. Attach filler panels with concealed fasteners.3. Attach sloping-top units to metal lockers, with closures at exposed ends.

E. Fixed Locker Benches: Provide no fewer than two pedestals for each bench, uniformly spaced not more than 72 inches (1830 mm) apart.

END OF SECTION 105113

Page 36: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

USPS-DELIVERY POSTAL SPECIALTIES 10550013Caron Architecture LLC © 2014

SECTION 105500.13 - USPS-DELIVERY POSTAL SPECIALTIES

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Mail receptacles.2. Cluster box units.3. Parcel lockers.4. Collection boxes.5. Accessories.

1.2 ACTION SUBMITTALS

A. Product Data: For each type of product.

B. Shop Drawings: For postal specialties. Include plans, elevations, sections, and attachment details.

C. Samples: For each type of exposed finish.

1.3 INFORMATIONAL SUBMITTALS

A. Sample warranty.

1.4 DELIVERY, STORAGE, AND HANDLING

A. Furnish lock keys according to USPS requirements; with temporary identification for their respective locks, bagged, and securely taped inside the collection compartment for shipping.

1.5 WARRANTY

A. Special Warranty: Manufacturer agrees to repair or replace components of postal specialtiesthat fail in materials or workmanship within specified warranty period.

1. Warranty Period: Five years from date of Substantial Completion.

PART 2 - PRODUCTS

Page 37: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

USPS-DELIVERY POSTAL SPECIALTIES 10550013Caron Architecture LLC © 2014

2.1 MAIL RECEPTACLES

A. Front-Loading Mail Receptacles: USPS-STD-4C; consisting of multiple compartments with fixed, solid compartment backs, enclosed within a recessed wall box.1. Basis-of-Design Product: Subject to compliance with requirements, provide Salisbury or

comparable product by one of the following:

a. 2B Global Inc.

b. American Eagle Mailbox; Division of Postal Products Unlimited, Inc.

c. Bommer Industries, Inc.

d. Charnstrom, W. A. Company.

e. Florence Corporation; a Gibraltar Industries company.

f. Jayco Industries.

g. Jensen Mailboxes; SCC Architectural Building Products.

h. National Mailboxes; a division of NMHP, Inc.

i. Postal Products Unlimited, Inc.

j. Security Manufacturing Corporation.

2. Front-Loading Master Door: Fabricated from extruded aluminum and braced and framed to hold compartment doors; prepared to receive master-door lock.

a. Master-Door Lock: Door prepared to receive lock provided by local postmaster.

3. Compartments: As indicated on Drawings.

a. Type I: A group of mail receptacles in single-column configuration with singlemaster door, [three] <Insert number up to eight> mail compartments not less than 3 inches high by 12 inches wide by 15 inches deep (76 mm high by 305 mm wide by 381 mm deep), one outgoing mail collection compartment prepared for master-door lock, and one parcel-locker compartment 15 inches high by 12 inches wide by 15 inches deep (381 mm high by 305 mm wide by 381 mm deep).

b. Type II: A group of mail receptacles in double-column configuration with double master door, [three] <Insert number up to 16> mail compartments not less than 3 inches high by 12 inches wide by 15 inches deep (76 mm high by 305 mm wide by 381 mm deep), one outgoing mail collection compartment prepared for master-door lock, and [one] [two] parcel-locker compartment(s): [15 inches high by 12 inches wide by 15 inches deep (381 mm high by 305 mm wide by 381 mm deep)] [and] [18 inches high by 12 inches wide by 15 inches deep (457 mm high by 305 mm wide by 381 mm deep)].

Page 38: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

USPS-DELIVERY POSTAL SPECIALTIES 10550013Caron Architecture LLC © 2014

c. Type III: A group of mail receptacles in double-column configuration with singlemaster door, [three] <Insert number up to 16> mail compartments not less than 3 inches high by 12 inches wide by 15 inches deep (76 mm high by 305 mm wide by 381 mm deep), one outgoing mail collection compartment prepared for master-door lock, and [one] [two] parcel-locker compartment(s): [15 inches high by 12 inches wide by 15 inches deep (381 mm high by 305 mm wide by 381 mm deep)] [and] [18 inches high by 12 inches wide by 15 inches deep (457 mm high by 305 mm wide by 381 mm deep)].

d. Type VI (No Parcel-Locker Compartment): A group of mail receptacles in single-column configuration with single master door, [three] <Insert number up to nine> mail compartments not less than 3 inches high by 12 inches wide by 15 inches deep (76 mm high by 305 mm wide by 381 mm deep), and one outgoing mail collection compartment prepared for master-door lock.

e. Type VIII (No Parcel-Locker Compartment): A group of mail receptacles in double-column configuration with double master door, [three] <Insert number up to 19>mail compartments not less than 3 inches high by 12 inches wide by 15 inches deep (76 mm high by 305 mm wide by 381 mm deep), and one outgoing mail collection compartment prepared for master-door lock.

4. Compartment Doors: Fabricated from extruded aluminum. Equip each with lock and tenant identification as required by USPS-STD-4C. Provide mail slot in the compartment with master-door lock.

a. Compartment-Door Locks: USPS-L-1172C; with three keys for each compartment door.

b. Parcel-Locker-Compartment-Door Locks: Two-key security system in which control key provides access to parcel-locker-compartment key, which opens compartment and is retained once opened.

5. Frames: Extruded aluminum or aluminum sheet; ganged and nested units, with cardholder and blank cards for tenant's identification within each compartment.

6. Concealed Components and Mounting Frames: Aluminum or steel sheet.7. Exposed Aluminum Finish:

a. Baked-Enamel or Powder-Coated Finish: Color as selected by Architect from manufacturer's full range.

2.2 PARCEL LOCKERS

A. Front-Loading Parcel Lockers, Recessed: USPS-STD-4C; consisting of single or multiple compartments enclosed within a larger enclosure of type indicated below.1. Basis-of-Design Product: Subject to compliance with requirements, provide Salisbury or

comparable product by one of the following:

a. American Eagle Mailbox; Division of Postal Products Unlimited, Inc.

b. Bommer Industries, Inc.

Page 39: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

USPS-DELIVERY POSTAL SPECIALTIES 10550013Caron Architecture LLC © 2014

c. Charnstrom, W. A. Company.

d. Florence Corporation; a Gibraltar Industries company.

e. Jayco Industries.

f. Jensen Mailboxes; SCC Architectural Building Products.

g. National Mailboxes; a division of NMHP, Inc.

h. Postal Products Unlimited, Inc.

i. Security Manufacturing Corporation.

2. Enclosure Type: Recessed.3. Compartments: As indicated on Drawings.

a. Type X, Parcel Only: Single parcel receptacle [15 inches high by 12 inches wide by 15 inches deep (381 mm high by 305 mm wide by 381 mm deep)] [18 inches high by 12 inches wide by 15 inches deep (457 mm high by 305 mm wide by 381 mm deep)] without a master door.

b. Type X, Parcel Only: A group of parcel receptacles in single-column configuration without a master door; [one] [two] compartment(s) 18 inches high by 12 inches wide by 15 inches deep ((457 mm high by 305 mm wide by 381 mm deep))[and][one compartment 15 inches high by 12 inches wide by 15 inches deep (381 mm high by 305 mm wide by 381 mm deep)].

c. Type XI, Parcel Only: A group of parcel receptacles in single-column configurationwith single master door prepared for master-door lock; [one] [two][compartment(s) 15 inches high by 12 inches wide by 15 inches deep (381 mm high by 305 mm wide by 381 mm deep)] [and] [one] [two] [compartment(s) 18inches high by 12 inches wide by 15 inches deep (457 mm high by 305 mm wide by 381 mm deep)].

4. Front-Loading Master Door: Fabricated to hold compartment doors; prepared to receive master-door lock provided by local postmaster.

5. Compartment Doors and Frames: Fabricated from same material and finish as adjacent mail receptacles. Equip each compartment door with lock; identification; and concealed, full-length, spring-loaded, flush hinge on right side.

a. Compartment Identification: Black, sequential numbers engraved into recess in face of compartment door.

b. Compartment-Door Locks: Dual-lock security system in which master lock provides access to customer lock (USPS-L-1172C) and parcel-locker key opens compartment and is retained once opened.

6. Aluminum Finish:

a. Baked-Enamel or Powder-Coated Finish: Color as selected by Architect from manufacturer's full range.

Page 40: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

USPS-DELIVERY POSTAL SPECIALTIES 10550013Caron Architecture LLC © 2014

2.3 ACCESSORIES

A. Key Keeper: Consisting of single compartment with door; interior compartment size not less than 4-3/4 inches wide by 2-1/4 inches high by 1-1/2 inches deep (121 mm wide by 57 mm high by 38 mm deep), USPS approved.1. Basis-of-Design Product: Subject to compliance with requirements, provide Salisbury or

comparable product by one of the following:

a. American Eagle Mailbox; Division of Postal Products Unlimited, Inc.

b. Bommer Industries, Inc.

c. Jayco Industries.

d. Jensen Mailboxes; SCC Architectural Building Products.

e. Florence Corporation; a Gibraltar Industries company.

f. Knox Company.

g. Postal Products Unlimited, Inc.

h. Security Manufacturing Corporation.

2. Mounting: Recessed.3. Style: Compartment door set within face frame.4. Type of Operation: Push-button, 24-V switch in box.5. Door Lock: Door prepared to receive lock furnished by local postmaster.6. Exposed Materials:

a. Anodic Finish: Clear.b. Baked-Enamel or Powder-Coated Finish: Architect to select from manufacturer’s

available colors.

2.4 FABRICATION

A. Form postal specialties to required shapes and sizes, with true lines and angles, square, rigid, and without warp, and with metal faces flat and free of dents or distortion. Make exposed metal edges and corners free of sharp edges and burrs and safe to touch. Fabricate doors of postal specialties to preclude binding, warping, or misalignment.

B. Preassemble postal specialties in shop to greatest extent possible to minimize field assembly.

C. Where dissimilar metals contact each other, protect against galvanic action by painting contact surfaces with bituminous coating or by applying other permanent separation as recommended by manufacturers of dissimilar metals.

Page 41: University Apartments on Brooklyn PROJECT MANUAL · J. Door Glazing: [Clear float glass] [Tempered float glass (clear)] [Tempered float glass (bronze tint)] [Break glass] [Tempered

University Apartments on Brooklyn

PROJECT MANUAL

USPS-DELIVERY POSTAL SPECIALTIES 10550013Caron Architecture LLC © 2014

PART 3 - EXECUTION

3.1 INSTALLATION

A. Mail Receptacles: Install mail receptacles with center of tenant-door lock cylinders and bottom of compartments at the maximum and minimum heights above finished floor established by the USPS and manufacturer's written instructions.

B. Pedestal-Mounted Postal Specialties: Anchor units with 1/2-inch- (13-mm-) diameter,stainless-steel anchor bolts with hooked ends.

C. Collection Boxes: Install collection boxes with centerline of mail slots not more than 48 inches(1219 mm) above finished floor.

3.2 FIELD QUALITY CONTROL

A. Arrange for USPS personnel to examine and test postal specialties served by the USPS after they have been installed according to USPS regulations.

END OF SECTION 105500.13