Universal XR Series Sample Pumps Cat. Nos. 224-44XR, 224 ...
Transcript of Universal XR Series Sample Pumps Cat. Nos. 224-44XR, 224 ...
Universal 44XRThe Economical Solution
Universal PCXR4The Compliance Solution
Universal PCXR8The Programmable Solution
SKC Inc. 724-941-9701 SKC-West 714-992-2780 SKC Gulf Coast 281-859-8050 SKC South 434-352-7149
www.skcinc.com
Flows: 5 to 5000 ml/min
Constant flows from 1 to 5 L/min
Low flows with holder from 5 to 500 ml/min
Long run times — 12+ hours at 4000 ml/min, 20 inches water back pressure
Heavy duty and lightweight — only 34 ounces (964 grams)
Built-in low flow pressure regulator for multi-tube sampling
Choose the automatic features that meet your requirements
Professionals’ choice since 1982
Turn on and sample! Economical
Basic operation
Convenient flow indicator
Designed for rugged industrial environments
Enhanced with programmability! Built-in high-accuracy timer
• Sample duration readout
Convenient HOLD feature
Automatic fault shutdown/time retention• Ensures sample integrity upon low battery
or excess back pressure
Delayed start• Set number of minutes to elapse until
sample start
Timed shutdown• Set number of minutes of operation
until shutdown
Intermittent sampling• Extend short-term samples over
an extended period to meet TWA requirements with fewer samples
• Extended intermittent sampling up to 7 days — ideal for fenceline monitoring!
Enhanced with additional features: Automatic fault shutdown and
time retention• Pump shuts down and retains sampling
time when battery is low or there is excessive back pressure to ensure sample integrity
High-accuracy timer• Built-in timer provides instant readout of
sampling duration.
Convenient HOLD feature • Allows for breaks
Universal XR Series Sample PumpsClassic Workhorse from 5 ml/min to 5 L/min
Certifications
intrinsically safe
ATEX-approved models available;
contact SKC
Publication 1580 Rev 1808
Performance ProfileFlow Control Accuracy Holds constant flow to ± 5% of set pointTiming Accuracy ± 0.05% (± 45 seconds per day)Typical Run Time Battery: 12 hrs minimum at 4000 ml/min and 20 inches water back pressure,
dependent on media usedBattery Eliminator: Pump provides extended runs. PCXR4 and PCXR8 display rolls over to 0 upon reaching 9999 min
Charge Time(varies with battery capacity and level of discharge)
6 to 8.5 hrs with PowerFlex charger
Temperature Range Operating: 32 to 104 F (0 to 40 C)Storage: -4 to 113 F (-20 to 45 C)Charging: 50 to 113 F (10 to 45 C)
Operating Humidity Range 0 to 95% non-condensingTimer Display Range PCXR4 and PCXR8 only: 1 to 9999 min (6.8 days)Timed Shutdown PCXR8 only: User-selectable time of operation before automatic shutdown.
Maximum setting is 9999 min (6.8 days)Delay On PCXR8 only: User-selectable time to delay test. Maximum setting is 9999 min (6.8 days)Intermittent Sampling PCXR8 only: User-selectable parameters to extend short-term samples over an extended
period. Elapsed time maximum is 9999 min (6.8 days).Flow and Low Battery Fault PCXR4 and PCXR8 only: Pump shuts down, timing functions pause, time display is retained,
and LCD indicates flow or low battery fault.Dimensions 5.1 x 4.7 x 1.9 in (13 x 11.9 x 4.8 cm)
Recommended AccessoriesChargersBattery EliminatorAdjustable Tube HoldersFilter HoldersTubingCases/Pouches
Flow Rate (ml/min)5 to 5000Weight in Ounces (grams)34 (964)Compensation Range (inches water)Up to 40 at 2 LBuilt-in Timer/ClockTimer — PCXR4 and PCXR8 onlyConstant FlowYesProgrammablePCXR8 onlyPC-compatibleN/A
Multi-tube SamplingYesFlow Fault FeaturePCXR4 and PCXR8 onlyRFI/EMI ShieldedYesIntrinsically Safe — UL ListedYesMSHA-approved Models AvailableContact SKCATEX Models AvailableYesCE MarkedYesCorrects for Changes in Atmospheric PressureN/ACorrects for Changes inTemperatureN/ABattery TypeNiMH (6.0 V, 3.5 Ah)Battery CheckPCXR4 and PCXR8 onlyTubingRequires 1/4-inch ID tubing
Universal XR Sample Pumps
Universal XR Sample PumpsSample pump with NiMH battery pack and screwdriver set. Low flow (5 to 500 ml/min) requires adjustable tube holder. Cat. No.PCXR8, requires charger 224-PCXR8PCXR4, requires charger 224-PCXR444XR, requires charger 224-44XRUniversal XR Starter KitsInclude pump with NiMH battery pack, single PowerFlex charger with cable, Tygon tubing (3 feet, 1/4-inch ID), and collar clip with cable tiePCXR8 100-240 V 224-PCXR8-SPCXR4 100-240 V 224-PCXR4-S44XR 100-240 V 224-44XR-SSingle High/Low Flow Pump KitsInclude sample pump with NiMH battery pack, single PowerFlex charger with cable, adjustable tube holder, Type A protective tube cover, filter cassette holder, and screwdriver set, in a convenient soft-side nylon carry case†
PCXR8 100-240 V 224-PCXR8KDPCXR4 100-240 V 224-PCXR4KDPCXR4 Single Pump Kit with IOM, does not include cassette holder 100-240 V 224-PCXR4PK44XR 100-240 V 224-44XRKD5-pack High/Low Flow Pump KitsInclude 5 each sample pumps with NiMH battery packs, adjustable tube holders, Type A protective tube covers, filter cassette holders, and screwdriver sets, and one 5-station PowerFlex charger with 5 cables, in a Pelican casePCXR8 100-240 V 224-PCXR8K5DPCXR4 100-240 V 224-PCXR4K5D44XR 100-240 V 224-44XRK5DReplacement Parts and AccessoriesReplacement Battery PackReplacing batteries with non-approved battery packs voids any warranty and UL intrinsic safety approvals. NiMH for XR models* P21661MH*Battery Eliminator, connects pump to line power for extended sampling 115 V 230 V
223-325223-325B
* Not suitable for MSHA-approved models† Single kits also available in hard-sided Pelican case. Contact SKC for ordering information.
Ordering InformationUniversal XR Pumps require 1/4-inch ID tubing.
SKC Inc. 724-941-9701 SKC-West 714-992-2780 SKC Gulf Coast 281-859-8050 SKC South 434-352-7149
www.skcinc.com
Quick View
SKC Limited Warranty and Return PolicySKC products are subject to the SKC Limited Warranty and Return Policy, which provides SKC’s sole liability and the buyer’s exclusive remedy. To view the complete SKC Limited Warranty and Return Policy, go to http://www.skcinc.com/warranty.