UNIVERSAL DESIGN- BARRIER
FREE ENVIRONMENTS
UNIVERSAL DESIGN IN CATALONIA Technical standards of Catalonia and Spain
The purpose of this presentation is :
• Make a summary of the accessibility tehnical standards of Catalonia (Construction)
• Make recommendations on accessibility issues not covered by the regulations
• Facilitate the understanding of the Universal Design concepts with photo and diagram examples
REGULATIONS:
• TECHNICAL BUILDING CODE (CTE). DB SUA. Royal Decree 314/2006
• ACCESSIBILITY CODE OF CATALUNYA
Decree 135/1995.
ACCESS ASPECTS:
• URBAN ACCESS
• ACCESS TO PREMISES-BUILDINGSACCESS TO PREMISES-BUILDINGS
• TRANSPORT ACCESSIBILITY
• ACCESSIBILITY IN COMMUNICATION
LEVELS OF ACCESS TO PREMISES-BUILDINGS.
TABLE OF USES AND ACTIVITIES:
• Classification based on the activity, use, and surface. DT-2.pdf
• Required level of accessibility. Annex2.pdf
ACCESS TO BUILDINGS:
• ACCESSIBLE: Raised thresholds should be avoided. Admitted a slope ≤ 2 cm beveled or rounded at 45º.
• According to the Code, practicable option allows a step height ≤ 12 cm. (Inadequate)
HORIZONTAL MOBILITY:• Width ≥ 0.9 m• Obstacle –free height ≥ 2.1 m (except doors where ≥ 2 m).• On each floor, it should be a turning space of 1.5m in diameter.• In case if direction change: a turning space of 1.2m in diameter. • Neither isolated steps, nor two consecutives steps are allowed. • Inclines of ≤ 5 cm should have a gradual slope ≤ 25% • Inclines of more than 5 cm high: adapted ramp.
DOORS:• Door width ≥ 0.8 m
• Height ≥ 2 m
• In case of glass door (no security door):– Height of the bottom base ≥ 30 cm.– Width of horizontal fringe ≥ 5 cm placed 1.5 m high and with high contrast
RAMPS:• Technical data / Decree 135/1995.• Length without flat space (L) and longitudinal slope (PDT) allowed:• L < 3m => pdt ≤ 12%. • 3 ≤ L < 6 m => pdt ≤ 10%. • 6 ≤ L < 9 m => pdt ≤ 10%• 9 ≤ L < 10 m => pdt ≤ 10%. Practicable: pdt ≤ 12%.• 10 ≤ L ≤ 20 m => pdt. ≤ 8%. Practicable: L shouldn’t be > 10 m• The cross slope is ≤ 2%, recommended of 0%.
RAMPS. HANDRAILS:• Anatomical design (section equivalent to a round tube 3 ÷ 5 cm in diameter).• Separated 4 cm from the vertical objects• Fastened firmly at the bottom and without obstacles for continuous hand
moviment • No need to put it if A <1.2 m and the difference between levels ≤ 0.15 m • The distance between intermediate rails shall be a maximum of 2.40 m.• Height: 0.9 ÷ 0.95 m. For children: height between 0.7 and 0.75 m height.• In case of width <1.2 m• Limited laterally by longitudinal protection or socle of ≥ 0.1 m above the
ground, if their edges are free.
Platforms and stair lifts:
• It is accepted their use in the existing buildings where it is physically impossible to install a lift or make a ramp
• CTE doesn’t mention it. Only lifts.
RESTROOMS:
• The doors should open outwards or be sliding• There must be a turning space of 1.50 meters in diameter• The lateral space at toilet, bath, shower and bidet, as well as in front of
sink > 0.8 m• The sink can not have anything below that hinders its use.• Mirrors should be framed and placed 0.90 m above the ground surface. • Indicators of men/women services have tactile signage “Men/women”,
with a letter "M" (men) or “W" (women) above the door handle. • There are two support rails at a height between 0.7 m 0.75 m near toilets
and bidets.• The bar at the accessway is swing-up.• All the accessories and mechanisms are placed at a height between 0.4
and 1.4 m.• The taps are driven by pressure mechanisms or lever.• The taps of bathtubs placed in the center, not at the edges.