Page 1: UNIT HEATER - Heinen & Hopman...240 V 3.0 kW 5.0 kW 7.5 kW 10.0 kW 15.0 kW 1 1 1 1 1 FE2-440360-042 FE2-440360-084 FE2-440360-168 FE2-440360-210 440 V 440 V 440 V 440 V 4.2 kW 8.4

Unit Heaters- HEINEN & HOPMAN 2020 © 1Unit Heaters - HEINEN & HOPMAN 2020 ©1

UNIT HEATERUNIT HEATERProducts

Ventilation Air Conditioning RefrigerationHeating

PROVIDED BYHEINEN & HOPMAN

Inside22ºC

OUTSIDE35°C45°C

HUMIDITY90%40%

Page 2: UNIT HEATER - Heinen & Hopman...240 V 3.0 kW 5.0 kW 7.5 kW 10.0 kW 15.0 kW 1 1 1 1 1 FE2-440360-042 FE2-440360-084 FE2-440360-168 FE2-440360-210 440 V 440 V 440 V 440 V 4.2 kW 8.4

Unit Heaters- HEINEN & HOPMAN 2020 © 1Unit Heaters - HEINEN & HOPMAN 2020 ©1

COMPANY INTRODUCTION

Heinen & Hopman is a reliable partner in the global maritime sector, offering top quality products and service in the field of climate control (HVAC & Refrigeration). The no-nonsense and entrepreneurial character of the founders who established the company in 1965 is still one of the main cornerstones of Heinen & Hopman. We support our clients using our knowledge and experience by realising the best possible climate control solutions; either fully customised or with varying degrees of standardisation. Like our clients, we are continuously active on a global scale to ensure that we can always be of service. We are also constantly searching for sustainable innovations as we aim for the best and very latest solutions in collaboration with our clients. Heinen & Hopman is critically aware that a company’s greatest asset is its employees – it is they who represent the added value of our business. Our goal is to continue to expand in the global market for maritime climate control solutions in a future-proof way.

In short, you can rely on Heinen & Hopman to deploy the know-how and expertise required to solve any heating, ventilation, air conditioning and refrigeration issue onboard ships. We see complexity as a challenge, no matter where your vessel may be.

OPERATING GLOBALLY

Global networking is crucial in every line of business and the shipping industry is certainly no exception. Being able to offer the highest quality of service and products to our clients at all times and in all places is of enormous importance to us. This is why Heinen & Hopman aims to keep expanding our network and know-how and ensure we are exactly where our clients need us to be.

Americas

Europe

Asia3

Countries11Offices

3Factories

220Employees

11Countries

22Offices

4Factories

1200Employees

7Countries

10Offices

7Factories

380Employees

Page 3: UNIT HEATER - Heinen & Hopman...240 V 3.0 kW 5.0 kW 7.5 kW 10.0 kW 15.0 kW 1 1 1 1 1 FE2-440360-042 FE2-440360-084 FE2-440360-168 FE2-440360-210 440 V 440 V 440 V 440 V 4.2 kW 8.4

Unit Heaters- HEINEN & HOPMAN 2020 © 2Unit Heaters - HEINEN & HOPMAN 2020 ©2

INTRODUCTION

Unit heatersThe unit heaters are primary used to heat large spaces outside the accommodation like workshops, engine room, etc. The heating is done by hot-air supply through a heating coil.

There are different types of heating units:

• Electrical heating unit: VLE heating units are mainly used in rough environments where boiler water is not available. The heating units are available from 3 kW to 36 kW.

• Explosion-proof electrical heating unit: FE2 heating units are ATEX certified unit heaters, specially developed for Ex II and EX IIB zone. The heating units are available from 2.5 kW to 23.1 kW.

• Hot-water heating unit: TGA heating units are the most common heating units used offshore and on board ships. The hot water from the boiler acts as heating medium. Steam can also be used as heating medium for higher efficiency. The heating units are available from 8.1 kW to 100 kW.

• Thermal-oil heating unit: Thermal-oil heating units are functionally similar to hot-water heating units. The heating units are mainly used in areas with extremely low temperatures. Thermal oil acts as heating medium. Thermal oil has a low freezing point and a high temperature limit up to 400 °C.

• Portable heating unit: Delta electrical heating units are easily movable and can be mounted to the wall with brackets for permanent installation. The heating units are available from 3 kW to 21 kW.

Unit Heaters- HEINEN & HOPMAN 2020 ©2

Page 4: UNIT HEATER - Heinen & Hopman...240 V 3.0 kW 5.0 kW 7.5 kW 10.0 kW 15.0 kW 1 1 1 1 1 FE2-440360-042 FE2-440360-084 FE2-440360-168 FE2-440360-210 440 V 440 V 440 V 440 V 4.2 kW 8.4

Unit Heaters- HEINEN & HOPMAN 2020 © 3Unit Heaters - HEINEN & HOPMAN 2020 ©3

VLE UNIT HEATERS

The VLE electrical fan heaters are designed for rough environments e.g. on ships, offshore, in workshops and large pro-duction areas.The heaters are available in three standard types: VLE-4, VLE-5 and VLE-6. The heaters are available in galvanized steel, but can also be supplied in different materials (on customer request).The heaters have a built-in thermostat (0-40 °C) which ensures optimal operation and minimizes the energy consump-tion. The heaters have a thermal fuse that turns off the heater at 110 °C.

Heating elementThe heaters have an electric tube heating element made of stainless steel (AISI304).

Standard versionThe heaters are supplied in 3 x 440V (AC) or 3 x 400V (AC), but very often applications require different voltages. All types are available from 230V to 3 x 690V, with output from 1.2 kW to 150 kW. Safety class IP44.

InstallationThe heaters can be mounted on the wall or ceiling (horizontally or vertically).

Capacity

VLE - 4Range 1.2 kW ~ 12.5 kW

Power3ph / 440V / 60Hz 3ph / 400V / 50Hz

(3 kW available in 230 V)

Dimension 610 x 460 x 560 (mm)

Air quantity 1440 m3/h

Sound level 75dB(A)

VLE - 5Range 16.5 kW ~ 25 kW

Power 3ph / 440V / 60Hz 3ph / 400V / 50Hz

Dimension 710 x 660 x 670 (mm)

Air quan-tity

2520 m3/h

Sound level 75dB(A)

VLE - 6Range 30.5 kW ~ 36 kW

Power 3ph / 440V / 60Hz 3ph / 400V / 50Hz

Dimension 910 x 660 x 760 (mm)

Air quantity 3960 m3/h

Sound level 75dB(A)

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure.

Scan the QR-code or visit heinenhopman.com

Page 5: UNIT HEATER - Heinen & Hopman...240 V 3.0 kW 5.0 kW 7.5 kW 10.0 kW 15.0 kW 1 1 1 1 1 FE2-440360-042 FE2-440360-084 FE2-440360-168 FE2-440360-210 440 V 440 V 440 V 440 V 4.2 kW 8.4

Unit Heaters- HEINEN & HOPMAN 2020 © 4Unit Heaters - HEINEN & HOPMAN 2020 ©4

FE2 UNIT HEATERS

FE2 electrical fan heaters are CE-marked & ATEX-approved for use in hazardous areas. The heaters are designed for loca-tions where specific explosive gases or dust may be present.

The heaters use the Vacucore. The induced vacuum within the sealed core provides greater efficiency, distribution of heat across the face of the exchanger and a faster warm-up. If necessary, the entire core can be safely and easily re-placed with a new exchanger or core.

The heaters are ATEX Approved (directive 94/9/EC) and Ex II 2 G, Ex d IIB T3 Gb-certified.

Heating elementThe heater core assembly has a sturdy, epoxy-coated, 14-gauge steel cabinet which carries the motor and fan assembly. Adjustable louvers allow directional control of the air flow. All fasteners are zinc-plated for corrosion protection.

Standard versionThe heaters are supplied in 50 Hz or 60 Hz. All types are available from 1 x 220V to 3 x 440V.

InstallationThe heaters can be mounted on the wall or ceiling (horizontally or vertically). Mounting kits are available on request.Mounting kits are made of steel with a wet-applied enamel paint. If the heater is installed on a structure that must be transported, provide additional support for the heater during transport. The suspended weight must not exceed 300 lbs (136 kg).

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure.

Scan the QR-code or visit heinenhopman.com

Page 6: UNIT HEATER - Heinen & Hopman...240 V 3.0 kW 5.0 kW 7.5 kW 10.0 kW 15.0 kW 1 1 1 1 1 FE2-440360-042 FE2-440360-084 FE2-440360-168 FE2-440360-210 440 V 440 V 440 V 440 V 4.2 kW 8.4

Unit Heaters- HEINEN & HOPMAN 2020 © 5Unit Heaters - HEINEN & HOPMAN 2020 ©5

SPECIFICATION FOR 50 HZ MODELS SPECIFICATION FOR 60 HZ MODELS

Model Voltage Nominal wattage

Phase

FE2-220150-025 FE2-220150-042 FE2-220150-063 FE2-220150-084 FE2-220150-126

220 V 220 V 220 V 220 V 220 V

2.5 kW 4.2 kW 6.3 kW 8.4 kW 12.6 kW

1 1 1 1 1

FE2-230150-028 FE2-230150-046 FE2-230150-069 FE2-230150-138

230 V 230 V 230 V 230 V

2.8 kW 4.6 kW 6.9 kW 13.8 kW

1 1 1 1

FE2-240150-030 FE2-240150-050 FE2-240150-075 FE2-240150-100 FE2-240150-150

240 V 240 V 240 V 240 V 240 V

3.0 kW 5.0 kW 7.5 kW 10.0 kW 15.0 kW

1 1 1 1 1

FE2-380350-025 FE2-380350-042 FE2-380350-063 FE2-380350-084 FE2-380350-125 FE2-380350-167 FE2-380350-209

380 V 380 V 380 V 380 V 380 V 380 V 380 V

2.5 kW 4.2 kW 6.3 kW 8.4 kW 12.5 kW 16.7 kW 20.9 kW

3 3 3 3 3 3 3

FE2-400350-028 FE2-400350-046 FE2-400350-069 FE2-400350-093 FE2-400350-139 FE2-400350-185 FE2-400350-231

400 V 400 V 400 V 400 V 400 V 400 V 400 V

2.8 kW 4.6 kW 6.9 kW 9.3 kW 13.9 kW 18.5 kW 23.1 kW

3 3 3 3 3 3 3

FE2-415350-037 FE2-415350-075 FE2-415350-149 FE2-415350-224

415 V 415 V 415 V 415 V

3.7 kW 7.5 kW 14.9 kW 22.4 kW

3 3 3 3

FE2-440350-042 FE2-440350-084 FE2-440350-168 FE2-440350-210

440 V 440 V 440 V 440 V

4.2 kW 8.4 kW 16.8 kW 21.0 kW

3 3 3 3

Model Voltage Nominal wattage

Phase

FE2-220160-025 FE2-220160-042 FE2-220160-063 FE2-220160-084 FE2-220160-126

220 V 220 V 220 V 220 V 220 V

2.5 kW 4.2 kW 6.3 kW 8.4 kW 12.6 kW

1 1 1 1 1

FE2-230160-028 FE2-230160-046 FE2-230160-069 FE2-230160-092 FE2-230160-138

230 V 230 V 230 V 230 V 230 V

2.8 kW 4.6 kW 6.9 kW 9.2 kW 13.8 kW

1 1 1 1 1

FE2-240160-030 FE2-240160-050 FE2-240160-075 FE2-240160-100 FE2-240160-150

240 V 240 V 240 V 240 V 240 V

3.0 kW 5.0 kW 7.5 kW 10.0 kW 15.0 kW

1 1 1 1 1

FE2-440360-042 FE2-440360-084 FE2-440360-168 FE2-440360-210

440 V 440 V 440 V 440 V

4.2 kW 8.4 kW 16.8 kW 21.0 kW

3 3 3 3

FE2-480360-030 FE2-440360-050 FE2-440360-075 FE2-440360-100 FE2-440360-150 FE2-440360-200

480 V 480 V 480 V 480 V 480 V 480 V

3.0 kW 5.0 kW 7.5 kW 10.0 kW 15.0 kW 20.0 kW

3 3 3 3 3 3

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure.

Scan the QR-code or visit heinenhopman.com

Page 7: UNIT HEATER - Heinen & Hopman...240 V 3.0 kW 5.0 kW 7.5 kW 10.0 kW 15.0 kW 1 1 1 1 1 FE2-440360-042 FE2-440360-084 FE2-440360-168 FE2-440360-210 440 V 440 V 440 V 440 V 4.2 kW 8.4

Unit Heaters- HEINEN & HOPMAN 2020 © 6Unit Heaters - HEINEN & HOPMAN 2020 ©6

HOT-WATER UNIT HEATERS

Hot-water unit heaters are primarily designed for heating of large rooms, workshops or production areas. The TGA 2000 heaters are designed for onshore and offshore objects.The heaters are manufactured in different sizes, with a heating capacity from 8.1 kW to 100 kW and an air flow from 1430 m³/h to 9370 m³/h.

Heating elementThe heaters use the boiler water as heating medium. The air will flow through the heating coil by using a axial or centri-fugal fan.The heaters are available with copper tube and aluminum fins, but can also be supplied with stainless-steel casing and galvanized-steel heat exchanger (suitable for rough environments e.g. on ships, offshore).Steam can also be used as heating medium for higher efficiency. The TGA 3000 heaters have a robust steel hot-dip galvanized heating coil, designed for steam heating.

For extremely low temperatures where water/glycol is not applicable, thermal oil can act as heating medium. The TGA 1000 heaters have a robust steel hot-dip galvanized heat exchanger, designed for use with hot water, overheated water or thermal oil.

More information on steam and thermal oil heaters on request.

Standard versionThe heaters have 2-speed motor ventilators. The motors have an externally rotating rotor.• Protection class: IP54• Insulation class: FOn request, special motors, e.g. 3-speed motors, EEx(e) or EEx(d) motors can be mounted. The heaters are available in 1 x 230V, 3 x 230V or 3 x 400V (2-speed or 3-speed).

InstallationThe TGA can be mounted on the wall or ceiling (horizontally or vertically).

Options• Double-sided air grid• Four-sided air grid• Drain (when used for cooling)• 2-speed switch• 5-step switch• Ceiling mounting kit• Wall mounting kit

TGA type Capacity kW (15°C, 70-90°C)

Air quantity m3/h

A mm

B mm

C mm

2300 8,1 - 18,2 1160-1430 450 355 450

2400 11,8 - 27,4 1860-2290 500 395 500

2500 19,1 - 45,5 3250-3850 600 425 600

2600 28,2 - 65,1 4460-5690 700 425 700

2700 41,9 - 100 7450-9370 800 425 800

Page 8: UNIT HEATER - Heinen & Hopman...240 V 3.0 kW 5.0 kW 7.5 kW 10.0 kW 15.0 kW 1 1 1 1 1 FE2-440360-042 FE2-440360-084 FE2-440360-168 FE2-440360-210 440 V 440 V 440 V 440 V 4.2 kW 8.4

Unit Heaters- HEINEN & HOPMAN 2020 © 7Unit Heaters - HEINEN & HOPMAN 2020 ©7

www.heinenhopman.com

Heinen & Hopman encourages a more

sustainable world. By providing eco-friendly solutions and serviceswe offer our clients

the option of reducing energy consumption

and thus CO2 emissions.

Ventilation Air Conditioning RefrigerationHeating

PROVIDED BYHEINEN & HOPMAN

Inside22ºC

OUTSIDE35°C45°C

HUMIDITY90%40%

AustriaT: +43 1720 1309E: [email protected]

BrazilT: +55 213 587 4241/4244E: [email protected]

CanadaT:+1 450 659 6571E: [email protected]

DenmarkT: +45 5164 1614E: [email protected]

France - La CiotatT: +33 4 4204 8685E: [email protected]

France - AntibesT: +33 4 8902 4562 E: [email protected]

GermanyT:+49 4073 1680E: [email protected]

GermanyT:+49 471 9869 300E: [email protected]

IndiaT: +91 336 499 1293E: [email protected]

ItalyT: +39 187 187 8500E: [email protected]

The Netherlands (HQ)T: +31 33 299 2500E: [email protected]

The Netherlands - RotterdamT: +31 18 020 9210E: [email protected]

NorwayT: +47 6919 0900E: [email protected]

Peoples Republic of ChinaT: +86 213 253 2896E: [email protected]

Peoples Republic of ChinaT: +86 510 8528 1763E: [email protected]

PolandT: +48 914 331 800E: [email protected]

RomaniaT: +40 236 448 222E: [email protected]

RussiaT: +7 812 449 3535E: [email protected]

SingaporeT: +65 6897 7879E: [email protected]

South KoreaT: +82 704 901 0000E: [email protected]

SpainT: +34 932 259 668E: [email protected]

SwedenT: +46 3121 7500E: [email protected]

TurkeyT: +90 216 493 8118E: [email protected]

UAE - Abu Dhabi T:+971 2550 4147E: [email protected]

UAE - DubaiT: +971 4263 5453E: [email protected]

USA - Seattle, Washington T: +1 206 632 7883E: [email protected]

USA - Fort Lauderdale, FloridaT: +1 954 463 0110E: [email protected]

USA - Houma, Louisiana T: +1 985 876 7982E: [email protected]

Do you require more information about our products or do you require advice? I am keen to help you further!

“ “

Eric Stoffelsen- Sales Manager [email protected]