Unicode 2 Series Customized Control Stations - Emerson · Unicode™ 2 Series Customized Control...

12
Unicode 2 Series Customized Control Stations Increased Safety Polyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum Applications Local control stations and motor control stations for use in hazardous areas covering the broadest possible range of applications. Control of equipment at: — Power plants — Chemical and petrochemical plants — Petroleum refineries — Reverse osmosis plants — Pulp and paper processing plants — Various industrial applications Push buttons and selector switches are used in conjunction with contactors or magnetic starters for remote control of motors in hazardous locations. They provide circuit control and/or selection. Pilot lights provide visual assurance that an electrical function is being performed at a remote or hazardous location. For use in washdown areas. Features Employs Ex de method of protection which eliminates the need for external seals. Operators include push buttons, illuminated push buttons, selector switches, control and load break switches and LED pilot lights. Pilot light employs high intensity single LED with lifetime of 100,000 hours that can be used at: — 12 Vac to 254 Vac 50/60 Hz — 12 Vdc to 60 Vdc Up to 3 contact blocks per actuator can be used. Contact block technical data: — IEC rated operating voltage (Ue): 500 Vac – 110 Vdc — IEC switching capacity: – AC 12: 16 Amps/400 Vac – AC 14: 10 Amps/400 Vac – AC 15: 6 Amps/500 Vac – DC 13: 2 Amps/24 Vdc and 1 Amp/110 Vdc — NEMA switching capacity: A600: 10 Amp/600 Vac Selector switch technical data: — IEC rated operating voltage: 690 Vac — IEC rated operating current: maximum 16 Amps — IEC switching capacity: – AC1: 16 Amps/690 Vac – AC15: 16 Amps/415 Vac – AC3: 8 Amps/500 Vac – AC3: 4 Amps/690 Vac – AC3: 16 Amps/690 Vac – DC1: 10 Amps/24 Vdc – DC1: 6 Amps/60 Vdc – DC1: 6 Amp/110 Vdc (2 contacts wired in series) – DC1: 6 Amp/220 Vdc (3 contacts in series) — NEMA switching capacity: A600: 10 Amps/600 Vac Enclosures are rated for IP66 with firmly secured gasket. Operators and contact blocks are spaced for easy wiring. Wide selection of termination methods available. Choice of DIN rail mounted high performance contact block suitable for low intensity (less than 5 mA). TS35 rail mounted components held securely in place during operation and easily removed for service. Brass Inserts are provided for TS35 DIN rails or mounting plate to be installed inside the enclosure. Captive, corrosion resistant stainless steel cover screws. Standard Materials Polyamide — Body, cover, cable gland and blanking plug: polyamide, black finish Fiberglass Reinforced Polyester (FRP) — Body and cover: fiberglass reinforced polyester, black finish Stainless Steel — Body, cover and cover screws: 316L stainless steel, natural finish Aluminum — Body and cover: aluminum with gray epoxy powder coating. Cable gland and blanking plug: polyamide Cover screws for 316L stainless steel or aluminum body: 304 stainless steel Cover screws for fiberglass reinforced polyester body: 316 stainless steel Optional nameplates: stainless steel Accessories Key for changing actuator blocks. Guard for mushroom head actuator. Padlockable guard. M5 and M6 earth stud. Combination drain and breather available in brass, polyamide and stainless steel. Polyester Polyamide Stainless Steel Aluminum Overall hazardous location and ingress protection rating depends on the rating of the optional certified components used. NEC: Class I, Division 2, Groups A, B, C, D Class II, Groups E, F, G Class III Ex de IIC/DIP A21 IP66, Type 4X CEC: Class I, Division 2, Groups A, B, C, D Class II, Groups F, G Class III; Type 4X Class I, Zone 1, AEx de IIC/ AEx tD 21 IP66 ATEX/IECEx: Zone 1 and 2 – 21 and 22 II 2 GD Ex de IIC/Ex demb IIC/ Ex tD A21 IP66 – IK10 CONTROLS CONTROLS: NEC/CEC, ATEX/IECEX INCREASED SAFETY CONTROL STATIONS Visit our website at www.emerson.com or contact us at (800) 621-1506. © August 2017 183

Transcript of Unicode 2 Series Customized Control Stations - Emerson · Unicode™ 2 Series Customized Control...

Page 1: Unicode 2 Series Customized Control Stations - Emerson · Unicode™ 2 Series Customized Control Stations ... Unicode™ 2 Series Customized Control Stations ... , No. 60079-0:07,

Unicode™ 2 Series Customized Control StationsIncreased SafetyPolyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum

Applications• Localcontrolstationsandmotorcontrolstationsforuse

inhazardousareascoveringthebroadestpossiblerangeofapplications.

• Controlofequipmentat:—Powerplants—Chemicalandpetrochemicalplants—Petroleumrefineries—Reverseosmosisplants—Pulpandpaperprocessingplants—Variousindustrialapplications

• Pushbuttonsandselectorswitchesareusedinconjunctionwithcontactorsormagneticstartersforremotecontrolofmotorsinhazardouslocations.Theyprovidecircuitcontroland/orselection.

• Pilotlightsprovidevisualassurancethatanelectricalfunctionisbeingperformedataremoteorhazardouslocation.

• Foruseinwashdownareas.

Features• EmploysExdemethodofprotectionwhicheliminatestheneed

forexternalseals.• Operatorsincludepushbuttons,illuminatedpushbuttons,

selectorswitches,controlandloadbreakswitchesandLEDpilotlights.

• PilotlightemployshighintensitysingleLEDwithlifetimeof100,000hoursthatcanbeusedat:

—12Vacto254Vac50/60Hz —12Vdcto60Vdc• Upto3contactblocksperactuatorcanbeused.• Contactblocktechnicaldata:

—IECratedoperatingvoltage(Ue):500Vac–110Vdc—IECswitchingcapacity: –AC12:16Amps/400Vac –AC14:10Amps/400Vac –AC15:6Amps/500Vac –DC13:2Amps/24Vdcand1Amp/110Vdc—NEMAswitchingcapacity:A600:10Amp/600Vac

• Selectorswitchtechnicaldata:—IECratedoperatingvoltage:690Vac—IECratedoperatingcurrent:maximum16Amps—IECswitchingcapacity: –AC1:16Amps/690Vac –AC15:16Amps/415Vac –AC3:8Amps/500Vac –AC3:4Amps/690Vac –AC3:16Amps/690Vac –DC1:10Amps/24Vdc –DC1:6Amps/60Vdc –DC1:6Amp/110Vdc(2contactswiredinseries)

–DC1:6Amp/220Vdc(3contactsinseries)—NEMAswitchingcapacity:A600:10Amps/600Vac

• EnclosuresareratedforIP66withfirmlysecuredgasket.• Operatorsandcontactblocksarespacedforeasywiring.• Wideselectionofterminationmethodsavailable.• ChoiceofDINrailmountedhighperformancecontact

blocksuitableforlowintensity(lessthan5mA).• TS35railmountedcomponentsheldsecurelyinplace

duringoperationandeasilyremovedforservice.• BrassInsertsareprovidedforTS35DINrailsormounting

platetobeinstalledinsidetheenclosure.

• Captive,corrosionresistantstainlesssteelcoverscrews.

Standard Materials• Polyamide

—Body,cover,cableglandandblankingplug:polyamide,blackfinish

• FiberglassReinforcedPolyester(FRP)—Bodyandcover:fiberglassreinforcedpolyester,blackfinish

• StainlessSteel—Body,coverandcoverscrews:316Lstainlesssteel,natural

finish• Aluminum

—Bodyandcover:aluminumwithgrayepoxypowdercoating.• Cableglandandblankingplug:polyamide• Coverscrewsfor316Lstainlesssteeloraluminumbody:

304stainlesssteel• Coverscrewsforfiberglassreinforcedpolyesterbody:

316stainlesssteel• Optionalnameplates:stainlesssteel

Accessories• Keyforchangingactuatorblocks.• Guardformushroomheadactuator.• Padlockableguard.• M5andM6earthstud.• Combinationdrainandbreatheravailableinbrass,polyamide

andstainlesssteel.

Polyester Polyamide

Stainless Steel Aluminum

Overall hazardous location and ingress protection rating depends on the rating of the optional certified components used.

NEC: Class I, Division 2, Groups A, B, C, D Class II, Groups E, F, G Class III Ex de IIC/DIP A21 IP66, Type 4X

CEC: Class I, Division 2, Groups A, B, C, D Class II, Groups F, G Class III; Type 4X Class I, Zone 1, AEx de IIC/ AEx tD 21 IP66

ATEX/IECEx: Zone 1 and 2 – 21 and 22

II 2 GD Ex de IIC/Ex demb IIC/ Ex tD A21 IP66 – IK10

ControlsControls: nEC/CEC, AtEX/IECEX InCrEAsEd sAfEty Control stAtIons

Visit our website at www.emerson.com or contact us at (800) 621-1506. © August 2017

183

Page 2: Unicode 2 Series Customized Control Stations - Emerson · Unicode™ 2 Series Customized Control Stations ... Unicode™ 2 Series Customized Control Stations ... , No. 60079-0:07,

Unicode™ 2 Series Customized Control StationsIncreased SafetyPolyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum

Options• Nameplates:Lamacoidwithdifferentcolorcombinations.• Padlockingfacilityatleft,center,rightoranypositionon

selectorswitches.• Padlockingfacilityformomentaryandmaintainedpushbuttons.

NEC/CEC Certifications and Compliances• FiberglassReinforcedPolyester(FRP)

—CertificationTypeCSPe—TemperatureClass:T5orT6—AmbientTemperature:-55°Cto+60°C(-67°Fto+140°F)—CAN/CSAStandards:C22.2No.0-M91,No.25-M66,No.

213-M1987.No.94-M91,No.60079-0:07,No.60529-2005,E60079-7-2003

—ULStandards:60079-0,60079-7,50—OtherStandards:ANSI/IEC60529-2004,ANSI/ISA12.12.01-

2011—cCSAusCertificate:2356952

• StainlessSteel—CertificationTypeJBe—TemperatureClass:T6(at+40°C)orT5(at+55°C)—SurfaceTemperature:T80°C(at+40°C)toT95°C

(at+55°C)(T176°FtoT203°F)—AmbientTemperature:-40°Cto+55°C(-40°Fto+131°F)—CAN/CSAStandard:C22.2No.O-M91,No.25-M66,No.

213-Ml987,No.60079-0:07,No.60529-2005,E60079-7-2003

—ULStandard:60079-0,60079-7—OtherStandards:ANSl/IEC60529-2004,

ANSI/ISA12.12.01-2011—cCSAusCertificate:2356734

ATEX/IECEx Certification and Compliances• Polyamide

—CertificationTypePCe—Gas:Zone1and2

–ConformingtoATEX94/9/CE: II2G–TypeofProtection:ExdeIIC/ExdembIIC–TemperatureClass:T6

—Dust:Zone21and22–ConformingtoATEX94/9/CE: II2D–TypeofProtection:ExtDA21

—SurfaceTemperature:T75°C(T167°F)—AmbientTemperature:-20°Cto+55°C(-4°Fto+131°F)—CEDeclarationofConformity:50221—ATEXCertificate:LCIE00ATEX6047—IndexofProtectionaccordingEN/IEC60529:IP66—ImpactResistance(shock):IK09

• FiberglassReinforcedPolyester(FRP)—CertificationTypeCSPe—Gas:Zone1and2

–ConformingtoATEX94/9/CE: II2G–TypeofProtection:ExdeIIC/ExdembIIC–TemperatureClass:T6

—Dust:Zone21and22–ConformingtoATEX94/9/CE: II2D–TypeofProtection:ExtDA21

—SurfaceTemperature:T75°C(T167°F)—AmbientTemperature:-55°Cto+60°C(-67°Fto+140°F)

(emptyenclosure,temperaturetobedetermineaccordingactuator)

—CEDeclarationofConformity:52084

—ATEXCertificate:LCIE00ATEX3032X—IECExCertificate:IECExLCI09.0016X

• StainlessSteel—CertificationTypeJBe—Gas:Zone1and2

–ConformingtoATEX94/9/CE: II2G–TypeofProtection:ExdeIIC/ExdembIIC–TemperatureClass:T5toT6

—Dust:Zone21and22–ConformingtoATEX94/9/CE: II2D–TypeofProtection:ExtDA21

—SurfaceTemperature:T80°CtoT95°C(T176°FtoT203°F)—AmbientTemperature:-50°Cto+70°C(-58°Fto+158°F)

(emptyenclosure,temperaturetobedetermineaccordingactuator)

—CEDeclarationofConformity:50232—ATEXCertificate:LCIE02ATEX6118X—IECExCertificate:LCI11.0008X—IndexofProtectionaccordingEN/IEC60529:IP66—ImpactResistance(shock):IK10

• Aluminum—CertificationTypePCe—Gas:Zone1and2

–ConformingtoATEX94/9/CE: II2G–TypeofProtection:ExdeIIC/ExdembIIC–TemperatureClass:T6

—Dust:Zone21and22–ConformingtoATEX94/9/CE: II2D–TypeofProtection:ExtDA21

—SurfaceTemperature:T75°C(T167°F)—AmbientTemperature:-55°Cto+60°C(-67°Fto+140°F)

(emptyenclosure,temperaturetobedetermineaccordingactuator)

—CEDeclarationofConformity:50221—ATEXCertificate:LCIE02ATEX6047—IndexofProtectionaccordingEN/IEC60529:IP66—ImpactResistance(shock):IK10

EURASEC Certification• CertificationTypePCe(Polyamide)

—EURASECRUC-FRГБ05.B.00911• CertificationTypeCSPe(FiberglassReinforcedPolyester)

—EURASECRUC-FRГБ05.B.00911• CertificationTypeJBe(StainlessSteel)

—EURASECRUC-FRГБ05.B.00911• CertificationTypePCe(Aluminum)

—EURASECRUC-FRГБ05.B.00911

Other Certification • CertificationTypePCe(Polyamide)

—INMETROCertificate:BVC11.0640-X• CertificationTypeCSPe(FiberglassReinforcedPolyester)

—INMETROCertificate:BVC11.0637-X• CertificationTypeJBe(StainlessSteel)

—INMETROCertificate:BVC11.0418-X

Overall hazardous location and ingress protection rating depends on the rating of the optional certified components used. INMETRO certification available on special request only. Contact your local sales representative for more information.

NEC: Class I, Division 2, Groups A, B, C, D Class II, Groups E, F, G Class III Ex de IIC/DIP A21 IP66, Type 4X

CEC: Class I, Division 2, Groups A, B, C, D Class II, Groups F, G Class III; Type 4X Class I, Zone 1, AEx de IIC/ AEx tD 21 IP66

ATEX/IECEx: Zone 1 and 2 – 21 and 22

II 2 GD Ex de IIC/Ex demb IIC/ Ex tD A21 IP66 – IK10

Cont

rols

Cont

rols

: nEC

/CEC

, AtE

X/IEC

EX In

CrEA

sEd

sAfE

ty C

ontr

ol s

tAtIo

ns

Visit our website at www.emerson.com or contact us at (800) 621-1506. © August 2017

184

Page 3: Unicode 2 Series Customized Control Stations - Emerson · Unicode™ 2 Series Customized Control Stations ... Unicode™ 2 Series Customized Control Stations ... , No. 60079-0:07,

Unicode™ 2 Series Customized Control StationsIncreased SafetyPolyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum

Catalog Numbering Guide - Unicode 2 Enclosures

U 2 3 W2 11 A1SA00G1SA00 T6

Series:U-ATEX/IECExCertified

Unicode2SeriesEnclosures

Size:1-Size12-Size23-Size3

CoverLayout:Size1,2and3available

See following page

Options:T6-M6earthstudT8-M8earthstudT1-M10earthstudP5-M5earthstud

forpolyamideorpolyester,M25entryrequired

P6-M6earthstudforpolyamideorpolyester,M20entryrequired

EP-Brassearthcontinuityplate(2xM20forpolyamidebox)

MaterialTypeandMounting:2-Polyesterrailmounted4-Polyamiderailmounted6-Stainlesssteelrailmounted8-Aluminumrailmounted

EntryConfiguration:Bottom,TopandFeedThru

availableSeebelow

Devices:1 to 6 devices per unit

Actuator,PilotLight,ContactBlocksandAccessories

Seefollowingpages

Entry Configuration

NPT Metric

1/2” 2 x 1/2” 3/4” 2 x 3/4” 1” M20 2 x M20 M25 2 x M25Bottom Z1 Z2 Z3 Z4 Z5 W1 W2 W3 W4Top Y1 Y2 Y3 Y4 Y5 V1 V2 V3 V4

FeedThru X1 X2 X3 X4 X5 U1 U2 U3 U4

Overall hazardous location and ingress protection rating depends on the rating of the optional certified components used. Polyamide versions: Only 2 x M20 available at bottom. Not recognized for use in any NEC/CEC governed hazardous areas.

NEC: Class I, Division 2, Groups A, B, C, D Class II, Groups E, F, G Class III Ex de IIC/DIP A21 IP66, Type 4X

CEC: Class I, Division 2, Groups A, B, C, D Class II, Groups F, G Class III; Type 4X Class I, Zone 1, AEx de IIC/ AEx tD 21 IP66

ATEX/IECEx: Zone 1 and 2 – 21 and 22

II 2 GD Ex de IIC/Ex demb IIC/ Ex tD A21 IP66 – IK10

ControlsControls: nEC/CEC, AtEX/IECEX InCrEAsEd sAfEty Control stAtIons

Visit our website at www.emerson.com or contact us at (800) 621-1506. © August 2017

185

Page 4: Unicode 2 Series Customized Control Stations - Emerson · Unicode™ 2 Series Customized Control Stations ... Unicode™ 2 Series Customized Control Stations ... , No. 60079-0:07,

Unicode™ 2 Series Customized Control StationsIncreased SafetyPolyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum

Drilled Cover Layout

Size 1

1 2 310

11

01 02 27 Size 2

21

1 1

4

32 1

65

32

4

32

65

V V

4

10

11

10

11

12

34 03 04 05 06 07 08 09 26 28 29 Size 3

20

21

1

4

1

4

7

1

5 6

2 3

4

10

11

12

13

2 3

5 6

2 3

4

7

1

5 6

7

2 3

5 6

7

5 6

1

8 9

25 10 11 12 13 14 15 16 17 18 19

2 3

5 6

8 9

V

4

V

5 6

V

4

7

V

5 6

7

2 3

5 6

14 15

16 17

14 15

18 19

16 175 6

V

20 21 22 23 24 30 31 32 33

Device Examples with OptionsDescription

Pushbuttonwith1NOcontactandgreen(unmarked)insert A5G

Pushbuttonwith1NCcontact,padlockingdeviceandred(unmarked)insert A92R

Pushbuttonwith2NOcontactsandSTARTgreeninsert A103

Pushbuttonwith2NOcontacts,padlockingdeviceandSTARTgreeninsert A1203

Pushbuttonwith2NOcontacts,padlockingdevice,STARTgreeninsertandDOWNsmalllegendplate

A1203SA10

Redpush-pullemergencystopmushroomheadwith2NCcontactsandpadlockingdevice D23

Redpush-pullemergencystopmushroomheadwith1NO+1NCcontactsandprotectiveguard D31

Redpush-pullemergencystopmushroomheadwith1NO+1NCcontactsandpadlockingdevice D33

Greenilluminatedpushbuttonwith1NOcontact LG5Greenilluminatedpushbuttonwith2NOcontacts,padlockingdeviceandSTARTgreeninsert LG1203

DescriptionGreenpilotlight PGRedpilotlightwithSTOPlargelegendplate PRLA082-positionrotaryactuatorwith2NOcontactsandpadlockingdevice H12

2-positionrotaryactuatorwith2NOcontactsandHAND—AUTOsmalllegendplate H1SH05

3-positionI—O—IIrotaryactuator(I+IImaintained)with2NOcontacts J1

3-positionI—O—IIrotaryactuator(I+IImaintained)with2NOcontactsandFORWARD—OFF—REVERSElargelegendplate

J1LJ06

2-position2-poleswitch US322-position2-poleswitchwith0—Ilargelegendplate US32 LH01

2-position4-poleswitch US352-position4-poleswitchwith0—Ilargelegendplate US35LH01

2position2-poleselectorswitchwithSTOP—STARTlargelegendplate US30LH04

3position2-poleselectorswitchwithOFF—0—ONlargelegendplate US31LJ02

Overall hazardous location and ingress protection rating depends on the rating of the optional certified components used. Stainless steel version only.

NEC: Class I, Division 2, Groups A, B, C, D Class II, Groups E, F, G Class III Ex de IIC/DIP A21 IP66, Type 4X

CEC: Class I, Division 2, Groups A, B, C, D Class II, Groups F, G Class III; Type 4X Class I, Zone 1, AEx de IIC/ AEx tD 21 IP66

ATEX/IECEx: Zone 1 and 2 – 21 and 22

II 2 GD Ex de IIC/Ex demb IIC/ Ex tD A21 IP66 – IK10

Cont

rols

Cont

rols

: nEC

/CEC

, AtE

X/IEC

EX In

CrEA

sEd

sAfE

ty C

ontr

ol s

tAtIo

ns

Visit our website at www.emerson.com or contact us at (800) 621-1506. © August 2017

186

Page 5: Unicode 2 Series Customized Control Stations - Emerson · Unicode™ 2 Series Customized Control Stations ... Unicode™ 2 Series Customized Control Stations ... , No. 60079-0:07,

Unicode™ 2 Series Customized Control Station FunctionsIncreased SafetyPolyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum

DevicesPush Buttons, Momentary Contacts (3 maximum)With2NOmomentarycontacts A1With2NCmomentarycontacts A2With1NO+1NCmomentarycontacts A3With2NO+1NCmomentarycontacts A4With1NOmomentarycontact A5With1NO+2NCmomentarycontacts A6With3NOmomentarycontacts A7With3NCmomentarycontacts A8With1NCmomentarycontact A9

Guard and Padlocking DevicesGuardformushroomheadpushbutton 1Padlockingdeviceforpushbuttonandrotaryactuator 2Padlockingdeviceformushroomheadpushbutton 3

Inserts for Push Buttons and Illuminated Push ButtonsGreen(unmarked) GRed(unmarked) RYellow(unmarked) YWhite(unmarked) WBlue(unmarked) BBlack(unmarked) NON(green) 01OFF(red) 02START(green) 03STOP(red) 04MARCHE(green) 05ARRET(red) 06I(green) 07O(red) 08

Legend PlatesLegend Plates for Push Buttons and Pilot Lights (Located Above Device)Text Small LargeBlank SA00 LA00ON SA01 LA01OFF SA02 LA02FORWARD SA03 LA03REVERSE SA04 LA04JOG SA05 LA05RUN SA06 LA06START SA07 LA07STOP SA08 LA08UP SA09 LA09DOWN SA10 LA10FAST SA11 LA11SLOW SA12 LA12RAISE SA13 LA13LOWER SA14 LA14OPEN SA15 LA15CLOSE SA16 LA16LOW SA17 LA17HIGH SA18 LA18TEST SA19 LA19RESET SA20 LA20

Legend Plates (Continued)Legend Plates for Push Buttons and Pilot Lights (Located Above Device)EMERGENCYSTOP SA21 LA21MARCHE SA22 LA22ARRET SA23 LA23ARRETD’URGENCE SA24 LA24HAUT SA25 LA25BAS SA26 LA26

DevicesIlluminated Push Buttons, Momentary Contacts (2 maximum)Greenwith2NOmomentarycontacts LG1Greenwith2NCmomentarycontacts LG2Greenwith1NO+1NCmomentarycontacts LG3Greenwith1NOmomentarycontacts LG5Greenwith1NCmomentarycontacts LG9Redwith2NOmomentarycontacts LR1Redwith2NCmomentarycontacts LR2Redwith1NO+1NCmomentarycontacts LR3Redwith1NOmomentarycontacts LR5Redwith1NCmomentarycontacts LR9

For other colors replace 2nd letter to B for Blue, W for White and Y for Yellow. Example: Blue — LB1

Device OptionsPush buttons complete with key removable in both positions (2 contacts maximum)With2NOcontacts E1With2NCcontacts E2With1NO+1NCcontacts E3With1NOcontact E5With1NCcontact E9

Push buttons complete with key removable in ON position(2 contacts maximum)With2NOcontacts F1With2NCcontacts F2With1NO+1NCcontacts F3With1NOcontact F5With1NCcontact F9

Push buttons complete with key removable in OFF position(2 contacts maximum)With2NOcontacts G1With2NCcontacts G2With1NO+1NCcontacts G3With1NOcontact G5With1NCcontact G9

Overall hazardous location and ingress protection rating depends on the rating of the optional certified components used.

NEC: Class I, Division 2, Groups A, B, C, D Class II, Groups E, F, G Class III Ex de IIC/DIP A21 IP66, Type 4X

CEC: Class I, Division 2, Groups A, B, C, D Class II, Groups F, G Class III; Type 4X Class I, Zone 1, AEx de IIC/ AEx tD 21 IP66

ATEX/IECEx: Zone 1 and 2 – 21 and 22

II 2 GD Ex de IIC/Ex demb IIC/ Ex tD A21 IP66 – IK10

ControlsControls: nEC/CEC, AtEX/IECEX InCrEAsEd sAfEty Control stAtIons

Visit our website at www.emerson.com or contact us at (800) 621-1506. © August 2017

187

Page 6: Unicode 2 Series Customized Control Stations - Emerson · Unicode™ 2 Series Customized Control Stations ... Unicode™ 2 Series Customized Control Stations ... , No. 60079-0:07,

Unicode™ 2 Series Customized Control Station FunctionsIncreased SafetyPolyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum

Device OptionsBlack Mushroom Head Push Buttons, Momentary Contacts (3 maximum)With2NOmomentarycontacts B1With2NCmomentarycontacts B2With1NO+1NCmomentarycontacts B3With2NO+1NCmomentarycontacts B4With1NOmomentarycontact B5With1NO+2NCmomentarycontacts B6With3NOmomentarycontacts B7With3NCmomentarycontacts B8With1NCmomentarycontact B9

DevicesRed Mushroom Head Push Buttons, Momentary Contacts (3 maximum)With2NOmomentarycontacts R1With2NCmomentarycontacts R2With1NO+1NCmomentarycontacts R3With2NO+1NCmomentarycontacts R4With1NOmomentarycontact R5With1NO+2NCmomentarycontacts R6With3NOmomentarycontacts R7With3NCmomentarycontacts R8With1NCmomentarycontact R9

Red Mushroom Head Emergency Stop Buttons, Maintained (3 contacts maximum)Push-pullversionwith2NOmaintainedcontacts D1Push-pullversionwith2NCmaintainedcontacts D2Push-pullversionwith1NO+1NCmaintainedcontacts D3

Push-pullversionwith2NO+1NCmaintainedcontacts D4

Push-pullversionwith1NOmaintainedcontact D5Push-pullversionwith1NO+2NCmaintainedcontacts D6

Push-pullversionwith3NOmaintainedcontacts D7Push-pullversionwith3NCmaintainedcontacts D8Push-pullversionwith1NCmaintainedcontact D9

Red Mushroom Head Emergency Stop Buttons, Maintained Contacts (2 maximum)Keytoreleasewith2NOmaintainedcontacts C1Keytoreleasewith2NCmaintainedcontacts C2Keytoreleasewith1NO+1NCmaintainedcontacts C3Keytoreleasewith1NOmaintainedcontact C5Keytoreleasewith1NCmaintainedcontact C9

LED Pilot LightsBluecolor PBGreencolor PGRedcolor PRWhitecolor PWYellowcolor PY

Devices2 Positions O-I Rotary Actuator (O and I Maintained)With2NOmaintainedcontacts H1With2NCmaintainedcontacts H2With1NO+1NCmaintainedcontacts H3With2NO+1NCmaintainedcontacts H4With1NOmaintainedcontact H5With1NO+2NCmaintainedcontacts H6With3NOmaintainedcontacts H7With3NCmaintainedcontacts H8With1NCmaintainedcontact H9

Legend Plates for 2-Position Selector Switches (Located Above Device)

Text Small LargeO—I SH01 LH01ON—OFF SH02 LH02START—STOP SH03 LH03STOP—START SH04 LH04HAND—AUTO SH05 LH05MANU—AUTO SH06 LH06FORWARD—REVERSE SH07 LH07REMOTE—LOCAL SH08 LH08MARCHE—ARRET SH09 LH09

3 Positions I-O-II Rotary Actuator (I and II maintained)With2NOmaintainedcontacts J1With2NCmaintainedcontacts J2With1NO+1NCmaintainedcontacts J3With2NO+1NCmaintainedcontacts J4With1NO+2NCmaintainedcontacts J6With3NOmaintainedcontacts J7With3NCmaintainedcontacts J8

3 Positions I-O-II Rotary Actuator (I and II spring-return to O)With2NOcontacts K1With2NCcontacts K2With1NO+1NCcontacts K3With2NO+1NCcontacts K4With1NO+2NCcontacts K6With3NOcontacts K7With3NCcontacts K8

3 Positions I-O-II Rotary Actuator (I Maintained and II Spring-Return to O)With2NOcontacts M1With2NCcontacts M2With1NO+1NCcontacts M3With2NO+1NCcontacts M4With1NO+2NCcontacts M6With3NOcontacts M7With3NCcontacts M8

3 Positions I-O-II Rotary Actuator (I Spring-Return to O + II Maintained)With2NOcontacts N1With2NCcontacts N2With1NO+1NCcontacts N3With2NO+1NCcontacts N4With1NO+2NCcontacts N6With3NOcontacts N7With3NCcontacts N8

Overall hazardous location and ingress protection rating depends on the rating of the optional certified components used.

NEC: Class I, Division 2, Groups A, B, C, D Class II, Groups E, F, G Class III Ex de IIC/DIP A21 IP66, Type 4X

CEC: Class I, Division 2, Groups A, B, C, D Class II, Groups F, G Class III; Type 4X Class I, Zone 1, AEx de IIC/ AEx tD 21 IP66

ATEX/IECEx: Zone 1 and 2 – 21 and 22

II 2 GD Ex de IIC/Ex demb IIC/ Ex tD A21 IP66 – IK10

Cont

rols

Cont

rols

: nEC

/CEC

, AtE

X/IEC

EX In

CrEA

sEd

sAfE

ty C

ontr

ol s

tAtIo

ns

Visit our website at www.emerson.com or contact us at (800) 621-1506. © August 2017

188

Page 7: Unicode 2 Series Customized Control Stations - Emerson · Unicode™ 2 Series Customized Control Stations ... Unicode™ 2 Series Customized Control Stations ... , No. 60079-0:07,

Unicode™ 2 Series Customized Control Station FunctionsIncreased SafetyPolyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum

Legend Plates for 3-Position Selector Switches (Located Above Device)

Text Small LargeI—O—II SJ01 LJ01OFF—O—ON SJ02 LJ02START—NORMAL—STOP SJ03 LJ03HAND—OFF—AUTO SJ04 LJ04MANUAL—O—AUTO SJ05 LJ05FORWARD—OFF—REVERSE SJ06 LJ06LOCAL—REMOTE—AUTO SJ07 LJ07LOCAL—O—REMOTE SJ08 LJ08MARCHE—NORMAL—ARRET SJ09 LJ09

Overall hazardous location and ingress protection rating depends on the rating of the optional certified components used. Additional configurations available. See Unicode 2 Series 16 Amp Switches in the Component and Accessories section. Choose the contact arrangement,

then add the last four digits of the switch part number in the custom configured control station catalog number. Ammeters are not NEC/CEC Certified.

NEC: Class I, Division 2, Groups A, B, C, D Class II, Groups E, F, G Class III Ex de IIC/DIP A21 IP66, Type 4X

CEC: Class I, Division 2, Groups A, B, C, D Class II, Groups F, G Class III; Type 4X Class I, Zone 1, AEx de IIC/ AEx tD 21 IP66

ATEX/IECEx: Zone 1 and 2 – 21 and 22

II 2 GD Ex de IIC/Ex demb IIC/ Ex tD A21 IP66 – IK10

DevicesAmmeters 48 x 48 mm 1AC.T.and3F.L.C.with0-1-3scale VA131AC.T.and5F.L.C.with0-1-5scale VA151AC.T.and6F.L.C.with0-1-6scale VA165AC.T.and3F.L.C.with0-1-3scale VA535AC.T.and5F.L.C.with0-1-5scale VA555AC.T.and6F.L.C.with0-1-6scale VA56

Box OptionsEarth StudM6earthstud T6M8earthstud T8M10earthstud T1M5earthstudforpolyamideorpolyester,M20entryrequired P5

M6earthstudforpolyamideorpolyester,M25entryrequired P6

Earth Continuity PlateBrass EP

PlugCoverblankingplug BP

ControlsControls: nEC/CEC, AtEX/IECEX InCrEAsEd sAfEty Control stAtIons

Visit our website at www.emerson.com or contact us at (800) 621-1506. © August 2017

189

Page 8: Unicode 2 Series Customized Control Stations - Emerson · Unicode™ 2 Series Customized Control Stations ... Unicode™ 2 Series Customized Control Stations ... , No. 60079-0:07,

Unicode™ 2 Series Customized Control Stations Ordering ExampleIncreased SafetyPolyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum

Ordering Example: Polyester Customized Control Station Specifications – Type U2

N

Polyester Customized Control Station Specifications — Type: U4

:sserddA:emaN ynapmoC

Contact:

Phone/Fax:

:tcejorP:liamE

Box Definition

2 eziS1 eziS

1

01

2 3

0203 *

1

04

1

4

05 *

32

06

1

65

07

32

4

08

32

65

09 *

V

26

V

4

Size 3

25

20

21

10 *

1

4

11

1

4

7

12 *

1

5 6

13 *

2 3

4

14

10

11

12

13

15 *

2 3

5 6

16

2 3

4

7

17

1

5 6

7

18

2 3

5 6

7

19

5 6

1

8 9

20

2 3

5 6

8 9

V

21 *

4

V

22 *

5 6

V

23

4

7

V

24

5 6

7

* Terminal block available as option. (maximum: 10 x terminals 2.5mm2)

Entry Position Entries (clearance hole) Earth Stud (At Bottom)� M20 � Without

� M25 � 3/4" NPT (via hub) � T6 Stainless Steel Earth Stud

Earth Continuity Plate � T8 Stainless Steel Earth Stud

Brass Earth Plate as Standard Location

� Stainless Steel Earth Plate � A � B � C � D � A, B, C, D

sgulPsdnalG elbaC� Without � Without� Type: Quantity: � Type: Quantity:

Nameplate

roloCepyTnoitpO

� Without � 58 x 18 Self-Adhesive Laminated Plastic � White (black letters) � Blue (white letters)

� With(complete Type and

color)

� 65 x 18 Screw On Laminated Plastic � Yellow (black letters) � Black (white letters)� 65 x 18 Screw On in Stainless steel

(available with black lettering only) � Red (white letters) � Green (white letters)

Text (1 line):

Functions

Position Actuator Contacts Insert Legend Plate Guard

)mumixam 01( ytitnauQepyT)lanoitpo( skcolB lanimreT *

Option for Box No. 03-05-09-10-12-13-15-21-22 only 2.5 mm2

Additional Instructions:

X

X X

X

XX

X X

Polyester Control Station

• Size3with3verticalactuators.• 2xM20entriesatbottomwithbrass

earthcontinuityplate.• Withoutearthstud.• Withoutcableglandsandplugs.• Whiteself-adhesivenameplatewith

blacklettering.• Text:MOTOR4• Position1:Greenpilotlightwithout

legendplate.• Position2:Greenstartpushbutton

with2xNOcontacts.• Greenstartinsertwithoutlegend

plateandguard.• Position7:Emergencystoppush-

pullmushroomheadwith2xNCcontactswithoutlegendplateandguard.

PartNo.:U23W211 PG A103 D2

The following inquiry forms should be filled out and sent to your local Appleton/ATX Representative.

Overall hazardous location and ingress protection rating depends on the rating of the optional certified components used.

NEC: Class I, Division 2, Groups A, B, C, D Class II, Groups E, F, G Class III Ex de IIC/DIP A21 IP66, Type 4X

CEC: Class I, Division 2, Groups A, B, C, D Class II, Groups F, G Class III; Type 4X Class I, Zone 1, AEx de IIC/ AEx tD 21 IP66

ATEX/IECEx: Zone 1 and 2 – 21 and 22

II 2 GD Ex de IIC/Ex demb IIC/ Ex tD A21 IP66 – IK10

Cont

rols

Cont

rols

: nEC

/CEC

, AtE

X/IEC

EX In

CrEA

sEd

sAfE

ty C

ontr

ol s

tAtIo

ns

Visit our website at www.emerson.com or contact us at (800) 621-1506. © August 2017

190

Page 9: Unicode 2 Series Customized Control Stations - Emerson · Unicode™ 2 Series Customized Control Stations ... Unicode™ 2 Series Customized Control Stations ... , No. 60079-0:07,

Unicode™ 2 Series Customized Control Stations — Stainless SteelIncreased Safety

Stainless Steel Customized Control Station Specifications — Type: U6

CompanyName: Address:

Contact:

Phone/Fax:

Email: Project:

Box Definition

Size 1 Size 2 Size 3

1

01

10

11

27 03*

1

04

1

4

28 *

11

10

29

11

10

12

09*

V

26

V

4

30

2 3

5 6

31 *

14 15

16 17

32

14 15

18 19

16 17

33

5 6

V

* Terminal block available as option. (maximum: 10 x terminals 2.5 mm2)

Entry Position Entries — Clearance Hole Earth Stud — At BottomM20 T6StainlessSteelEarthStudasStandard

M25 T8StainlessSteelEarthStud

3/4”NPT(viahub)Location

A B C D A,B,C,D

Cable Glands PlugsWithout WithoutType: Quantity: Type: Quantity:

Nameplate

Option Type Color

Without 58x18mm(2.28x0.71”)Self-AdhesiveLaminatedPlastic White(blackletters) Blue(whiteletters)

With(completeTypeandcolor)

65x18mm(2.56x0.71”)ScrewOnLaminatedPlastic Yellow(blackletters) Black(whiteletters)

65x18mm(2.56x0.71”)ScrewOnStainlessSteel(available with black lettering only)

Red(whiteletters) Green(whiteletters)

Text(1line):

Functions

Position Actuator Contacts Insert Legend Plate Guard

* Terminal Blocks (optional) Type Quantity (10 maximum)

OptionforBoxNo.03-09-28-31only 2.5mm2

Additional Instructions:

Overall hazardous location and ingress protection rating depends on the rating of the optional certified components used. Please check with your sales representative for hazardous location and ingress protection rating accuracy.

NEC: Class I, Division 2, Groups A, B, C, D Class II, Groups E, F, G Class III Ex de IIC/DIP A21 IP66, Type 4X

CEC: Class I, Division 2, Groups A, B, C, D Class II, Groups F, G Class III; Type 4X Class I, Zone 1, AEx de IIC/ AEx tD 21 IP66

ATEX/IECEx: Zone 1 and 2 – 21 and 22

II 2 GD Ex de IIC/Ex demb IIC/ Ex tD A21 IP66 – IK10

ControlsControls: nEC/CEC, AtEX/IECEX InCrEAsEd sAfEty Control stAtIons

Visit our website at www.emerson.com or contact us at (800) 621-1506. © August 2017

191

Page 10: Unicode 2 Series Customized Control Stations - Emerson · Unicode™ 2 Series Customized Control Stations ... Unicode™ 2 Series Customized Control Stations ... , No. 60079-0:07,

Unicode™ 2 Series Customized Control Stations — PolyesterIncreased Safety

Polyester Customized Control Station Specifications — Type: U4

CompanyName: Address:

Contact:

Phone/Fax:

Email: Project:

Box Definition

Size 1 Size 2

1

01

2 3

02 03 *

1

04

1

4

05 *

32

06

1

65

07

32

4

08

32

65

09 *

V

26

V

4

Size 3

25

20

21

10 *

1

4

11

1

4

7

12 *

1

5 6

13 *

2 3

4

14

10

11

12

13

15 *

2 3

5 6

16

2 3

4

7

17

1

5 6

7

18

2 3

5 6

7

19

5 6

1

8 9

20

2 3

5 6

8 9

V

21 *

4

V

22 *

5 6

V

23

4

7

V

24

5 6

7

* Terminal block available as option. (maximum: 10 x terminals 2.5 mm2)

Entry Position Entries — Clearance Hole Earth Stud — At BottomM20 Without

M25 3/4”NPT(viahub) T6StainlessSteelEarthStud

Earth Continuity Plate T8StainlessSteelEarthStud

BrassEarthPlateasStandard Location

StainlessSteelEarthPlate A B C D A,B,C,D

Cable Glands PlugsWithout WithoutType: Quantity: Type: Quantity:

Nameplate

Option Type Color

Without 58x18mm(2.28x0.71”)Self-AdhesiveLaminatedPlastic White(blackletters) Blue(whiteletters)

With(completeTypeandcolor)

65x18mm(2.56x0.71”)ScrewOnLaminatedPlastic Yellow(blackletters) Black(whiteletters)

65x18mm(2.56x0.71”)ScrewOninStainlesssteel(available with black lettering only) Red(whiteletters) Green(whiteletters)

Text(1line):

Functions

Position Actuator Contacts Insert Legend Plate Guard

* Terminal Blocks (optional) Type Quantity (10 maximum)

OptionforBoxNo.03-05-09-10-12-13-15-21-22only 2.5mm2

Additional Instructions:

Overall hazardous location and ingress protection rating depends on the rating of the optional certified components used. Please ensure to check with your sales representative for hazardous location and ingress protection rating accuracy.

NEC: Class I, Division 2, Groups A, B, C, D Class II, Groups E, F, G Class III Ex de IIC/DIP A21 IP66, Type 4X

CEC: Class I, Division 2, Groups A, B, C, D Class II, Groups F, G Class III; Type 4X Class I, Zone 1, AEx de IIC/ AEx tD 21 IP66

ATEX/IECEx: Zone 1 and 2 – 21 and 22

II 2 GD Ex de IIC/Ex demb IIC/ Ex tD A21 IP66 – IK10

Cont

rols

Cont

rols

: nEC

/CEC

, AtE

X/IEC

EX In

CrEA

sEd

sAfE

ty C

ontr

ol s

tAtIo

ns

Visit our website at www.emerson.com or contact us at (800) 621-1506. © August 2017

192

Page 11: Unicode 2 Series Customized Control Stations - Emerson · Unicode™ 2 Series Customized Control Stations ... Unicode™ 2 Series Customized Control Stations ... , No. 60079-0:07,

Unicode™ 2 Series Customized Control Stations — AluminumIncreased Safety

Aluminum Customized Control Station Specifications — Type: U8

CompanyName: Address:

Contact:

Phone/Fax:

Email: Project:

Box Definition

Size 1 Size 2

1

01

2 3

02 03 *

1

04

1

4

05 *

32

06

1

65

07

32

4

08

32

65

09 *

V

26

V

4

Size 3

25

20

21

10 *

1

4

11

1

4

7

12 *

1

5 6

13 *

2 3

4

14

10

11

12

13

15 *

2 3

5 6

16

2 3

4

7

17

1

5 6

7

18

2 3

5 6

7

19

5 6

1

8 9

20

2 3

5 6

8 9

V

21 *

4

V

22 *

5 6

V

23

4

7

V

24

5 6

7

* Terminal block available as option. (maximum: 10 x terminals 2.5 mm2)

Entry Position Entries — Clearance Hole Earth Stud — At BottomM20 T5ExternalEarthStudasStandard

M25 T6StainlessSteelEarthStud

3/4”NPT(viahub) T8StainlessSteelEarthStud

Location

A B C D A,B,C,D

Cable Glands PlugsWithout WithoutType: Quantity: Type: Quantity:

Nameplate

Option Type Color

Without 58x18mm(2.28x0.71”)Self-AdhesiveLaminatedPlastic White(blackletters) Blue(whiteletters)

With(completeTypeandcolor)

65x18mm(2.56x0.71”)ScrewOnLaminatedPlastic Yellow(blackletters) Black(whiteletters)

65x18mm(2.56x0.71”)ScrewOninStainlesssteel(available with black lettering only) Red(whiteletters) Green(whiteletters)

Text(1line):

Functions

Position Actuator Contacts Insert Legend Plate Guard

* Terminal Blocks (optional) Type Quantity (10 maximum)

OptionforBoxNo.03-05-09-10-12-13-15-21-22only 2.5mm2

Additional Instructions:

Overall hazardous location and ingress protection rating depends on the rating of the optional certified components used. Please ensure to check with your sales representative for hazardous location and ingress protection rating accuracy.

ATEX/IECEx: Zone 1 and 2 – 21 and 22

II 2 GD Ex de IIC/Ex demb IIC/ Ex tD A21 IP66 – IK10

ControlsControls: nEC/CEC, AtEX/IECEX InCrEAsEd sAfEty Control stAtIons

Visit our website at www.emerson.com or contact us at (800) 621-1506. © August 2017

193

Page 12: Unicode 2 Series Customized Control Stations - Emerson · Unicode™ 2 Series Customized Control Stations ... Unicode™ 2 Series Customized Control Stations ... , No. 60079-0:07,

ATEX/IECEx: Zone 1 and 2 – 21 and 22

II 2 GD Ex de IIC/Ex demb IIC/Ex tD A21 IP66 – IK09

Unicode™ 2 Series Customized Control Stations — PolyamideIncreased Safety

Polyamide Customized Control Station Specifications — Type: U4

CompanyName: Address:

Contact:

Phone/Fax:

Email: Project:

Box Definition

Size 1 Size 2 Size 3

1

01 34

21

04

1

4

09

V

25

20

21

11

1

4

7

21

V

4

23

V

4

7

Entry Position Entries — Clearance Hole Earth Stud — At Bottom

M20 Without

T6StainlessSteelEarthStud(viaM20entry)Earth Continuity Plate

BrassEarthPlate

StainlessSteelEarthPlate

Cable Glands Plugs

Without Without

Type: Quantity: Type: Quantity:

Nameplate

Option Type Color

Without 58x18mm(2.28x0.71”)Self-AdhesiveLaminatedPlastic

White(blackletters) Blue(whiteletters)

With(completeTypeandcolor)

Yellow(blackletters) Black(whiteletters)

Red(whiteletters) Green(whiteletters)

Text(1line):

Functions

Position Actuator Contacts Insert Legend Plate Guard

Additional Instructions:

Cont

rols

Cont

rols

: nEC

/CEC

, AtE

X/IEC

EX In

CrEA

sEd

sAfE

ty C

ontr

ol s

tAtIo

ns

Visit our website at www.emerson.com or contact us at (800) 621-1506. © August 2017

194