UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701 Cover Letter XX/XX/XXXX Vendor Company Vendor: Enclosed are the results from the SAS-3 Clause 5 Physical Layer testing performed on the: Device Under Test The testing was performed according to Version 1.00 of the UNH IOL SAS Consortium Clause 5 SAS-3 Physical Layer Test Suite, which is available online at: http://www.iol.unh.edu/testsuites/sas/ Note that the tests defined in this test suite are based on Clause 5 of the SAS-3 specification, ISO/IEC 14776-154:201x, Serial Attached SCSI-3 (SAS-3) Standard T10/2212-D, Revision 05a. Please feel free to contact me at [email protected] if you have any questions regarding the test suite, or the results contained in this report. Sincerely, Michael Klempa

Transcript of UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 ....

Page 1: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0

InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701 Cover Letter

XX/XX/XXXX Vendor Company Vendor:

Enclosed are the results from the SAS-3 Clause 5 Physical Layer testing performed on the:

Device Under Test The testing was performed according to Version 1.00 of the UNH IOL SAS Consortium Clause 5

SAS-3 Physical Layer Test Suite, which is available online at:

http://www.iol.unh.edu/testsuites/sas/ Note that the tests defined in this test suite are based on Clause 5 of the SAS-3 specification,

ISO/IEC 14776-154:201x, Serial Attached SCSI-3 (SAS-3) Standard T10/2212-D, Revision 05a. Please feel free to contact me at [email protected] if you have any questions regarding the test

suite, or the results contained in this report.

Sincerely,

Michael Klempa

Page 2: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 2 Document 1.0

Digital Signature Information

This document was created using an Adobe digital signature. A digital signature helps to ensure the authenticity of the document, but only in this digital format. For information on how to verify the integrity of this document, please proceed to the following site:

http://www.iol.unh.edu/certifyDoc/

If, after following the steps indicated above, the document status still indicates “Validity of author NOT confirmed”, please contact the UNH-IOL to confirm the document’s authenticity. To further validate the certificate integrity, Adobe 6.0 should report the following fingerprint information:

MD5 Fingerprint (2013): 16 16 87 29 8D 1D 3C A4 1E 95 EE 03 7B 1B 2B 7D SHA-1 Fingerprint (2013): 48 9E 57 F1 09 34 9A DA 39 4C 82 16 11 6B 11 AE 1E 4D 3B 7E

Page 3: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 3 Document 1.0

Table 1: Test Equipment and DUT Configuration/Feature Information DUT Details Manufacturer Model SAS Device Type (IT/CT) Mfr. Serial Number Port Tested Firmware Version Hardware Version Software Version UNH-IOL ID Number DUT: Reported Features DUT is a CT device DUT is an IT device that supports SATA DUT supports SSC on TX Test System Hardware Real-time DSO Agilent Infiniium DSO91304A, 13GHz, 40GS/s Real-time

DSO Sampling Scope Agilent DCA-J 86100C, with 86108B 50GHz Precision

Waveform Analyzer MDI-to-SMA Adapter Wilder Technologies SAS Receptacle Test Adapter Part No.

600-1008-000 Vector Network Analyzer Agilent E5071C ENA Additional Comments/Notes S-Parameter measurements (Table 5, and Figures 19 through 30) were initially performed with the SAS mated connector pair included, and the TX and RX common-mode return loss results were both observed to be outside the conformance limits. (Note this is a common and expected problem, due to the common-mode characteristics of most SAS connectors.) The common-mode S-parameters were re-measured using timegating to remove the connector from the measurements. The eyemask used for 12G is informative.

Page 4: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 4 Document 1.0

Table 2: Group 1 - TX OOB Signaling Tests Test/Parameter Valid Range Measured Units Figure

Test 5.1.1: AC TX Maximum Noise During OOB Idle Maximum peak-to-peak OOB idle noise < 120 35.9 mVppd 1 Test 5.1.2: TX OOB Burst Amplitude (ZL Test Load): < 1600 1208.1 mVppd 2 (ZL Test Load): > 240 740.1 mVppd 2 (3G TCTF Load): < 1600 1047.7 mVppd 3 (3G TCTF Load): > 240 614.3 mVppd 3 Test 5.1.3: TX OOB Offset Delta Mean differential voltage during OOB burst -25/+25 -3.4 mV 1 Test 5.1.4: TX OOB Common Mode Delta Mean common-mode voltage during OOB burst -50/+50 (61.9) mV 4

Page 5: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 5 Document 1.0

Table 3: Group 2 - TX SSC Requirements Test/Parameter Valid Range Measured Units Fig.

Test 5.2.1: TX SSC Modulation Frequency Frequency of SSC modulation 30/33 31.15 kHz 6 Test 5.2.2: TX SSC Modulation Deviation and Balance (If DUT is a SAS phy that supports Down-spreading): Average upper SSC peak value: < 100 83.7 ppm 6 Average lower SSC peak value: > -1000 -789.2 ppm 6 (If DUT is an Expander phy that supports Center-spreading):

Average upper SSC peak value: < 1000 N/P* ppm 8 Average lower SSC peak value: > -1000 N/P* ppm 8 Deviation Asymmetry: < 288 N/P* ppm 8 (If DUT is an Expander phy that supports Down-spreading when connected to SATA devices):

Average upper SSC peak value: < N/A N/A* ppm - Average lower SSC peak value: > N/A N/A* ppm - Test 5.2.3: TX SSC dF/dt (Informative) Peak dF/dt: (SAS Down-spreading case) -850/+850 661.4 ppm/us 7 Peak dF/dt: (SAS Center-spreading case) -850/+850 N/P* ppm/us 9 Peak dF/dt: (SATA Down-spreading case) -850/+850 N/A* ppm/us - *N/P: This test was not performed because the DUT does not support SSC Center spreading. *N/A: This test is not applicable.

Page 6: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 6 Document 1.0

Table 4: Group 3 - TX NRZ Data Signaling Requirements Test/Parameter Range Measured Units Figure

Test 5.3.1: TX Physical Link Rate Long Term Stability Mean TX bitrate (SSC disabled): -100/+100 -6.8 ppm 10 Test 5.3.2: TX Common Mode RMS Voltage Limit RMS common-mode voltage: < 30 3.4 mV Test 5.3.3: TX Common Mode Spectrum Minimum margin with respect to limit line: > 0 See Figure dBmV 11 Test 5.3.4: TX Peak-to-Peak Voltage TX peak-to-peak voltage: 536/1200 747.0 mV 12 Test 5.3.5: TX VMA and EQ TX Voltage Modulation Amplitude: >= 80 677.5 mV 13 TX Equalization: 2/4 (1.82) dB 13 Test 5.3.6: TX Rise and Fall Times TX rise time while transmitting 1010 pattern: >= 20.8 25.1 ps 14 TX fall time while transmitting 1010 pattern: >= 20.8 24.5 ps 14 Test 5.3.7: TX Random Jitter (RJ) Peak-to-peak RJ @ 1E-12 BER with 1100 pattern: <= 150 (169.2) mUI - Test 5.3.8: TX Total Jitter (TJ) Pk-pk TJ with 1100 pattern (SSC disabled): <= 250 182.4 mUI 15 Pk-pk TJ with 1100 pattern (SSC Down-spreading): <= 250 182.4 mUI 16 Pk-pk TJ with 1100 pattern (SSC Center-spreading): <= 250 N/P1* mUI 17 Test 5.3.9: TX Waveform Distortion Penalty (WDP) SASWDP result for SCRAMBLED_0 pattern: < 13 N/P2* dB 18 * N/P1: This test was not performed because the DUT does not support SSC Center spreading. * N/P2: This test was not performed, as it does not apply to this rate.

Page 7: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 7 Document 1.0

Table 5: Group 4 - S-Parameter Requirements Test/Parameter Range Measured Units Fig.

Test 5.4.1: RX Differential Return Loss (SDD11) Minimum SDD11 margin: > 0 6.04 dB 19 Test 5.4.2: RX Common-Mode Return Loss (SCC11) Minimum SCC11 margin: > 0 16.10 dB 20 Test 5.4.3: RX Differential Impedance Imbalance (SCD11) Minimum SCD11 margin: > 0 11.65 dB 21 Test 5.4.4: TX Differential Return Loss (SDD22) Minimum SDD22 margin: > 0 3.64 dB 22 Test 5.4.5: TX Common-Mode Return Loss (SCC22) Minimum SCC22 margin: > 0 18.15 dB 23 Test 5.4.6: TX Differential Impedance Imbalance (SCD22) Minimum SCD22 margin: > 0 5.58 dB 24

Page 8: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 8 Document 1.0

Figure 1: TX Idle Noise and TX Offset Delta (Zero-Length Test Load)

Page 9: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 9 Document 1.0

Figure 2: OOB Maximum and Minimum Amplitude (Zero-Length Test Load)

Page 10: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 10 Document 1.0

Figure 3: OOB Maximum and Minimum Amplitude (3G TCTF)

Page 11: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 11 Document 1.0

Figure 4: TX OOB Common-Mode Delta (Zero-Length Test Load)

Page 12: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 12 Document 1.0

Figure 5: SSC + Link Rate Stability LPF Test Filter Response

Page 13: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 13 Document 1.0

Figure 6: SSC Profile (1010 Pattern, SAS Down-Spreading Case)

Page 14: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 14 Document 1.0

Figure 7: SSC dF/dt (1010 Pattern, SAS Down-Spreading Case)

Page 15: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 15 Document 1.0

Figure 8: SSC Profile (1010 Pattern, SAS Center-Spreading Case)

Page 16: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 16 Document 1.0

Figure 9: SSC dF/dt (1010 Pattern, SAS Center-Spreading Case)

Page 17: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 17 Document 1.0

Figure 10: TX Physical Link Rate Long Term Stability (1010 Pattern, SSC OFF)

Page 18: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 18 Document 1.0

Figure 11: TX Common Mode RMS Voltage Spectrum (CJTPAT Pattern, SSC OFF)

Page 19: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 19 Document 1.0

Figure 12: TX Vpp (D30.3 Pattern, SSC OFF)

Page 20: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 20 Document 1.0

Figure 13: TX VMA and EQ (TRAIN_DONE Pattern, SSC OFF)

Page 21: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 21 Document 1.0

Figure 14: TX Rise and Fall Times (1010 Pattern, SSC OFF)

Page 22: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 22 Document 1.0

Figure 15: TX Eye Diagram (1100 Pattern, SSC OFF)

Page 23: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 23 Document 1.0

Figure 16: TX Eye Diagram (1100 Pattern, SSC Down-Spreading)

Page 24: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 24 Document 1.0

Figure 17: TX Eye Diagram (1100 Pattern, SSC Center-Spreading)

Page 25: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 25 Document 1.0

Figure 18: SASWDP BER Eye (SCRAMBLED_0 Pattern, SSC OFF)

Page 26: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 26 Document 1.0

Figure 19: Ungated RX Differential Return Loss (SDD11)

Page 27: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 27 Document 1.0

Figure 20: Gated RX Common-Mode Return Loss (SCC11)

Page 28: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 28 Document 1.0

Figure 21: Ungated RX Differential Impedance Imbalance (SDC11)

Page 29: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 29 Document 1.0

Figure 22: Ungated TX Differential Return Loss (SDD22)

Page 30: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 30 Document 1.0

Figure 23: Gated TX Common-Mode Return Loss (SCC22)

Page 31: UNH IOL SAS Consortium 3.0... · UNH IOL SAS Consortium SAS-3 Phy Layer Test Suite v1.0 . InterOperability Lab — 121 Technology Drive, Suite 2 — Durham, NH 03824 — (603) 862-0701

The University of New Hampshire InterOperability Laboratory DUT: UNH-IOL ID

UNH IOL SAS Consortium SAS-3 Physical Layer Test Suite v1.00 31 Document 1.0

Figure 24: Ungated TX Differential Impedance Imbalance (SDC22)