UNEP MEETING – BANGKOK - April 2015
HFCs Elimination in Foams for Domestic and Commercial Appliances
Challenges and Opportunities
Paulo Altoe’ The Dow Chemical - BrazilDOW CONFIDENTIAL - Do not share without permission 1
UNEP MEETING – BANGKOK 2015
DOW CONFIDENTIAL - Do not share without permission
Lambda & Energy Efficiency
Mechanical performance; Applied density
Flammability: Plant and Machinery Investment $$
Elimination Timeframe: Experiments; Cabinet Redesign; Field Evaluation; $
Processing: Corrosion, Adhesion; Temperature control; Investment $
Foam competitiveness: $
HFOs: Availability; Cost $
Challenges
2
HFOs Blown Foams Versus other blowing agents – Domestic & Commercial Appliances
DOW CONFIDENTIAL - Do not share without permission
HFOs
Lambda & Energy ~ 12% better
versus HC Foams*Similar to better
versus HFCs
* Applied density lower versus HC
and HFCs
*HFC365/227ea *HFC245fa * Solstice ® LBA * Formacel® 1100 *Cp-Isopentane 70/30
30
31
32
33
34
35
36
18.00
18.50
19.00
19.50
20.00
20.50
21.00
21.50
22.00
Mol
ded
Den
sity
, kg/
m3
Lam
bda,
mW
/mK
@ 2
4C
Standard System for Appliances (Mediunm Reactivity) HFC365/227ea and CP-Isopentane as Controls
Molded Density and K Factor
3
Flammable Blowing Agents Comparison – Water Blown as Control
DOW CONFIDENTIAL - Do not share without permission
*Methylal *Methyl Formate *Cp-Isopentane 70/30
#All Water Blown32.00
33.00
34.00
35.00
36.00
37.00
38.00
39.00
40.00
19.00
19.50
20.00
20.50
21.00
21.50
22.00
22.50
23.00
23.50
24.00M
olde
d D
ensi
ty, k
g/m
3Systems Comparison - Flammable Blowing Agents versus Water Blown
Lam
bda,
mW
/mK
@ 2
4C
* Lambda of Methylal and Methyl Formate are similar to water blown
* High applied density
for water blown
* HC has the best compromise of performance
4
HFOs System with High Water Content versus Full Water Blown
HFOs
*Lower molded density versus H2O blown
* Lambda improvement
versus H2O blown
* Cost reduction in combination with high
water content
DOW CONFIDENTIAL - Do not share without permission 5
Final Remarks • Hydrocarbon Technology , traditionaly used in the market, is a feasible alternative for
HFCs, apart from heavy investment for conversion
• Water Blown or WB combined wtih HFOs can replace HFCs in cases where lambda is not so critical. Balanced levels of HFOs can meet Hydrocarbons performance
• Methylal and Mehtyl Formate are flammable , but with very small concentration they could be used to reduce molded density in water blown systems, in cases where lambda is not so critical. Corrosion must be addressed if Methyl Formate is the option
• HFOs represent a feasible technical alternative to address HFCs replacement with advantages in lambda and molded density
• HFOs are liquid and non flammble, requiring almost no investiment for HFCs conversion
• HFOs represent a heavy penalty in foam costs that can be minimized with lower concentration in the foam composition
• Shelf lije stability for fully formulated polyols contaning HCFO must be improved
• Product availability is still limited for HFOs
DOW CONFIDENTIAL - Do not share without permission 6
Paulo Altoe’ - Product Technology Manager The Dow Chemical - Brazil [email protected]
DOW CONFIDENTIAL - Do not share without permission
THANK YOU
7
Backup Slides
DOW CONFIDENTIAL - Do not share without permission 8
Blowing Agents Properties
Table 1 – Blowing Agent Properties [ Most recent data from literature and suppliers ]
DOW CONFIDENTIAL - Do not share without permission 9
Blowing Agents (BAs) Evolution
* The evolution of BAs technologies, driven by regulation and market trends moved far from 1st generation BAs (CFCs) * Uses of Gen 1 and 2 is regulated by Montreal protocol (Ozone Depletion Potential , ODP) * HFCs high Global Warming Potential (GWP) substances are currently not regulated. However, market trends indicate that they will probably be regulated in the future. * On top of Hydrocarbons (HC) and water, HFO Gen 4, Hydrofluoroolefins will represent a viable Low GWP alternative to HFCs
Gen1 Gen 2
Gen 3
Gen 4
High ODPHigh GWP
Low ODPHigh GWP
Zero ODPHigh GWP
Zero ODPLow GWP
CFC-11 HCFC-141b HFC 134aHFC 245fa
HFC 365mfcHFC 227ea
HFOs
Hydrocarbons, Methylal, Methyl Formate and Water
DOW CONFIDENTIAL - Do not share without permission 10