Ultrafast light sources and methods for attosecond pump-probe experiments
Transcript of Ultrafast light sources and methods for attosecond pump-probe experiments
Ultrafast light sources and
methods for attosecond
pump-probe experiments
Davide Fabris
March 2015
Thesis submitted in partial fulfilment of the
requirements for the degree of Doctor of
Philosophy of Imperial College London and the
Diploma of Imperial College
Laser Consortium
Quantum Optics and Laser Science Group
Department of Physics
Imperial College London
London, SW7 2BW
United Kingdom
2
Declaration
I hereby certify that the work presented in this thesis is my own unless stated
otherwise.
Davide Fabris
The copyright of this thesis rests with the author and is made available un-
der a Creative Commons Attribution Non-Commercial No Derivatives licence.
Researchers are free to copy, distribute or transmit the thesis on the condition
that they attribute it, that they do not use it for commercial purposes and that
they do not alter, transform or build up on it. For any reuse or redistribution,
researchers must make clear to others the licence terms of this work.
3
Abstract
In this thesis I describe the development of novel light sources to be applied
in attosecond pump-probe experiments, together with new methods dedicated
to their characterisation and optimisation.
Femtosecond pulses are a necessary tool to enter the attosecond domain.
For this reason their development is a key element to unlock more capabili-
ties in pump-probe attosecond experiments. The dynamics of generation and
compression of few-cycle femtosecond pulses has been studied in a hollow core
fibre system. The carrier envelope phase stability performance under increas-
ing input power to the fibre system has been examined systematically, showing
the effects of ionisation on the carrier envelope phase stability.
Two characterisation techniques have been developed to measure ultrafast
femtosecond pulses. A version of the d-scan technique has been demonstrated
in the single shot regime for the first time, extending the utility of this diag-
nostic. An all optical technique (ARIES) for the characterisation of the full
waveform of a femtosecond pulse has been developed, exploiting the high har-
monics generation process and the sensitivity of the cut-off emission to the
instantaneous amplitude of the generating electric field.
The main results of the thesis are concerned with the generation of isolated
attosecond pulses in new spectral regions. Vacuum ultraviolet few-femtosecond
and attosecond pulses have been generated by filtering with metallic foils the
high harmonics emission driven by sub-4 fs pulses, and were characterised
with the attosecond streaking technique. When using indium as spectral filter
a pulse duration of 1.7±0.1 fs was measured at a photon energy of 15 eV. When
using tin as spectral filter a pulse duration of 585 ± 31 as was measured at a
photon energy of 20 eV. The experimental techniques developed in this thesis
allow these pulses to be generated simultaneously with a XUV pulse with a
measured duration of 270± 25 as. This work will open new opportunities for
pump-probe experiments, for example studies of ultrafast charge migration in
large molecules.
5
Contents
Abstract 3
List of Figures 12
List of Tables 13
1 Introduction 15
1.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1.2 Author’s contribution . . . . . . . . . . . . . . . . . . . . . . . . 18
1.3 Author publications . . . . . . . . . . . . . . . . . . . . . . . . . 19
2 Theory and background 21
2.1 Ultrafast lasers . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
2.1.1 Mathematical description . . . . . . . . . . . . . . . . . 21
2.1.2 Dispersion . . . . . . . . . . . . . . . . . . . . . . . . . . 25
2.1.3 Non-linear optics . . . . . . . . . . . . . . . . . . . . . . 31
2.1.4 Short pulse production . . . . . . . . . . . . . . . . . . . 36
2.2 Characterisation techniques . . . . . . . . . . . . . . . . . . . . 39
2.2.1 Autocorrelation . . . . . . . . . . . . . . . . . . . . . . . 39
2.2.2 Frequency Resolved Optical Gating . . . . . . . . . . . . 42
2.2.3 Spectral Phase Interferometry for Direct Electric field
Reconstruction . . . . . . . . . . . . . . . . . . . . . . . 45
2.2.4 CEP measurement and stabilisation . . . . . . . . . . . . 48
2.3 Strong field physics . . . . . . . . . . . . . . . . . . . . . . . . . 50
6 CONTENTS
2.3.1 Ionisation . . . . . . . . . . . . . . . . . . . . . . . . . . 50
2.3.2 High Harmonics Generation . . . . . . . . . . . . . . . . 54
3 Ultrafast light sources development 63
3.1 Laser System . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
3.1.1 Oscillator . . . . . . . . . . . . . . . . . . . . . . . . . . 64
3.1.2 Amplifier . . . . . . . . . . . . . . . . . . . . . . . . . . 66
3.2 Hollow core fibre pulse compression . . . . . . . . . . . . . . . . 68
3.2.1 Experimental setup . . . . . . . . . . . . . . . . . . . . . 75
3.2.2 Results and discussion . . . . . . . . . . . . . . . . . . . 78
3.3 HHG for isolated VUV and XUV pulses production . . . . . . . 81
3.3.1 Gating the HHG emission . . . . . . . . . . . . . . . . . 81
3.3.2 Experimental setup . . . . . . . . . . . . . . . . . . . . . 84
3.3.3 Spectral results . . . . . . . . . . . . . . . . . . . . . . . 86
3.4 Plasma HHG . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
3.4.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . 93
3.4.2 Experimental results . . . . . . . . . . . . . . . . . . . . 94
4 New methods for attosecond pump-probe experiments 99
4.1 Dispersion-Scan . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
4.1.1 Standard d-scan . . . . . . . . . . . . . . . . . . . . . . . 100
4.1.2 Single shot implementation . . . . . . . . . . . . . . . . 101
4.1.3 Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
4.2 Attosecond Resolved Interferometric
Electric-field Sampling . . . . . . . . . . . . . . . . . . . . . . . 109
4.2.1 Concept . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
4.2.2 Experimental setup . . . . . . . . . . . . . . . . . . . . . 112
4.3 Electron Velocity Map Imaging and ion time-of-flight . . . . . . 120
4.3.1 VMI background theory . . . . . . . . . . . . . . . . . . 120
4.3.2 Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
CONTENTS 7
5 Attosecond streaking of XUV and VUV pulses 127
5.1 Theoretical background . . . . . . . . . . . . . . . . . . . . . . . 128
5.1.1 Retrieval algorithms for streaking experiments . . . . . . 130
5.2 XUV and VUV streaking experiment . . . . . . . . . . . . . . . 134
5.2.1 Experimental setup . . . . . . . . . . . . . . . . . . . . . 134
5.3 Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
5.3.1 XUV Results . . . . . . . . . . . . . . . . . . . . . . . . 142
5.3.2 VUV Results . . . . . . . . . . . . . . . . . . . . . . . . 148
6 Conclusions and future work 161
Bibliography 165
Appendix A Retrieval algorithms 187
A.1 PCGPA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
A.2 LSGPA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
Appendix B Copyright permissions 193
B.1 Item 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
B.2 Item 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
B.3 Item 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196
B.4 Item 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
B.5 Item 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
B.6 Item 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199
B.7 Item 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
9
List of Figures
2.1 Gaussian beam . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2.2 CEP definition . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
2.3 Dispersion effects . . . . . . . . . . . . . . . . . . . . . . . . . . 27
2.4 Prism pair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
2.5 Chirped mirror . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
2.6 Non-linear optics . . . . . . . . . . . . . . . . . . . . . . . . . . 32
2.7 Second harmonic generation . . . . . . . . . . . . . . . . . . . . 34
2.8 Self-phase modulation . . . . . . . . . . . . . . . . . . . . . . . 35
2.9 Mode Locking . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
2.10 Kerr-Lens Mode-Locking . . . . . . . . . . . . . . . . . . . . . . 37
2.11 CPA technique . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
2.12 Spectrometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
2.13 Field autocorrelation setup . . . . . . . . . . . . . . . . . . . . . 40
2.14 Field autocorrelation trace . . . . . . . . . . . . . . . . . . . . . 40
2.15 Intensity autocorrelation setup . . . . . . . . . . . . . . . . . . . 41
2.16 Intensity autocorrelation trace . . . . . . . . . . . . . . . . . . . 42
2.17 Spectrogram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
2.18 Projection algorithm . . . . . . . . . . . . . . . . . . . . . . . . 44
2.19 SPIDER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
2.20 SPIDER Analysis . . . . . . . . . . . . . . . . . . . . . . . . . . 46
2.21 SEA-F-SPIDER . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
2.22 Interferometry f − 2f . . . . . . . . . . . . . . . . . . . . . . . 48
10 LIST OF FIGURES
2.23 Ionisation Dynamics . . . . . . . . . . . . . . . . . . . . . . . . 51
2.24 ADK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
2.25 Three-step model . . . . . . . . . . . . . . . . . . . . . . . . . . 55
2.26 Typical HHG spectrum . . . . . . . . . . . . . . . . . . . . . . . 55
2.27 Trajectories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
2.28 Long andShort trajectories . . . . . . . . . . . . . . . . . . . . . 58
2.29 HHG phase-matching . . . . . . . . . . . . . . . . . . . . . . . . 62
3.1 Oscillator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
3.2 CEP fast loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
3.3 Amplifier Layout . . . . . . . . . . . . . . . . . . . . . . . . . . 66
3.4 CEP slow loop . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
3.5 Fibre modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
3.6 Fibre losses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
3.7 Fibre design parameters . . . . . . . . . . . . . . . . . . . . . . 74
3.8 Fibre setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
3.9 Focal spot size . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
3.10 Fibre spectra . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
3.11 Fibre CEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
3.12 Fibre transmission . . . . . . . . . . . . . . . . . . . . . . . . . 78
3.13 Fibre gas pressure . . . . . . . . . . . . . . . . . . . . . . . . . . 79
3.14 Fibre CEP stabilitye . . . . . . . . . . . . . . . . . . . . . . . . 80
3.15 Beamline layout . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
3.16 Gas jet schematics . . . . . . . . . . . . . . . . . . . . . . . . . 85
3.17 Flat field spectrometer calibration . . . . . . . . . . . . . . . . . 86
3.18 XUV and VUV spectra . . . . . . . . . . . . . . . . . . . . . . . 87
3.19 Kr-Xe Low harmonics comparison . . . . . . . . . . . . . . . . . 87
3.20 Phase-matching conditions for the XUV and VUV spectra . . . 88
3.21 CEP scan for the XUV and VUV spectra . . . . . . . . . . . . . 89
3.22 Interaction effects on XUV and VUV spectra . . . . . . . . . . . 90
LIST OF FIGURES 11
3.23 Flat field XUV spectra CEP scan . . . . . . . . . . . . . . . . . 92
3.24 Four step model . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
3.25 Plasma plumes HHG . . . . . . . . . . . . . . . . . . . . . . . . 96
4.1 Pulse measurement with d-scan . . . . . . . . . . . . . . . . . . 101
4.2 Prism for single shot d-scan . . . . . . . . . . . . . . . . . . . . 103
4.3 Single shot d-scan setup . . . . . . . . . . . . . . . . . . . . . . 104
4.4 Single shot d-scan calibration . . . . . . . . . . . . . . . . . . . 105
4.5 Single shot and scanning d-scan traces . . . . . . . . . . . . . . 106
4.6 Single shot and scanning d-scan results. . . . . . . . . . . . . . . 107
4.7 HHG CEP dependence . . . . . . . . . . . . . . . . . . . . . . . 109
4.8 ARIES concept . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
4.9 ARIES theoretical traces . . . . . . . . . . . . . . . . . . . . . . 112
4.10 ARIES setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
4.11 ARIES CEP measurement . . . . . . . . . . . . . . . . . . . . . 115
4.12 ARIES dispersion measurement . . . . . . . . . . . . . . . . . . 116
4.13 ARIES 2ω simulation . . . . . . . . . . . . . . . . . . . . . . . . 119
4.14 Electron VMI and ion TOF detectors . . . . . . . . . . . . . . . 120
4.15 Abel transform for VMI . . . . . . . . . . . . . . . . . . . . . . 121
4.16 VMI images for different β . . . . . . . . . . . . . . . . . . . . . 123
4.17 Electron VMI and ion TOF performance summary . . . . . . . 125
4.18 Electron VMI and ion TOF results . . . . . . . . . . . . . . . . 126
5.1 Theoretical streaking traces . . . . . . . . . . . . . . . . . . . . 130
5.2 Retrieval algorithm . . . . . . . . . . . . . . . . . . . . . . . . . 131
5.3 Retrieval algorithm comparison . . . . . . . . . . . . . . . . . . 133
5.4 TOF chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
5.5 Two part mirror assembly . . . . . . . . . . . . . . . . . . . . . 135
5.6 Filters for XUV and VUV pulse selection . . . . . . . . . . . . . 136
5.7 Combination of attosecond pulses . . . . . . . . . . . . . . . . . 137
5.8 Temporal overlap for straking experiment . . . . . . . . . . . . . 138
12 LIST OF FIGURES
5.9 TOF lens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
5.10 TOF calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
5.11 CEP scan with the TOF spectrometer . . . . . . . . . . . . . . 143
5.12 XUV-NIR raw and smoothed streaking traces. . . . . . . . . . . 144
5.13 NIR pulse extraction from streaking traces . . . . . . . . . . . . 145
5.14 XUV pulse retrievals . . . . . . . . . . . . . . . . . . . . . . . . 147
5.15 Photon flux calibration . . . . . . . . . . . . . . . . . . . . . . . 150
5.16 Indium raw and smoothed traces . . . . . . . . . . . . . . . . . 153
5.17 Indium LSGPA results . . . . . . . . . . . . . . . . . . . . . . . 154
5.18 Calibration traces for the TOF nozzle . . . . . . . . . . . . . . . 156
5.19 Tin raw and smoothed traces . . . . . . . . . . . . . . . . . . . 157
5.20 Tin LSGPA results . . . . . . . . . . . . . . . . . . . . . . . . . 158
13
List of Tables
3.1 Visibility of harmonics generated in ablation plumes. . . . . . . 95
5.1 Photon flux estimate from count rate . . . . . . . . . . . . . . . 150
5.2 Photon flux measurement results . . . . . . . . . . . . . . . . . 151
5.3 Pulses properties . . . . . . . . . . . . . . . . . . . . . . . . . . 159
14
Acknowledgements
First of all many thanks to John for his great supervision. Not only he wasalways supportive and available for technical and scientific advice, but he wasalso always able to cheer us up when the morale was a bit down, either forlong and unfruitful scans in the lab, or just because it was another raining dayin London. Thanks to Jon for his relentless supervision and constant advicethroughout my PhD.
I would like to thank all the people of the Atto Lab. I would like to thankTobi for teaching me a lot, from the very basics of laser science, to the morenerdy features of Matlab. Thanks to Tom, for bringing new and interestingknowledge in our group, and to Will, for trying to educate people about propervacuum procedures and jazz music. Thanks to Zara, Daniel and Paloma, forhelping a lot in the lab and making it a nice place to be.
I would like to thank all the Laser Consortium, where I had the luck to findmore than just colleagues. A big thank to a big guy, Steffen, for the long chatsand the many pints we had together. Thanks to Jon and Peter for makinggoing to the pub a true British experience. Thanks to all the others, thanksDane for having that big brain of yours, thanks Felicity for the cow pictures.Thanks Sid, Malte Richard, Marco, Martin, Emma, Hazel, Zsolt, Bridgette,Emilio, Nick, Konstantin, Allan, Alvaro and Lukas for making the office awelcoming place.
I would like to thank the people that saved the day more than once. ThanksJudith and Marcia for making things happening, from purchase orders to sem-inars. Thanks Peter, Andy and Susan to turn our ideas in the equipment weare so proud of.
I would like to thank all the friends that made London feel a bit more likehome. Thanks to Gabriele, for being a good friend and for dragging me to thegym. Thanks to the Andreas (aka the colleagues) , for sharing the never-a-joymoments with a good laugh.
A very big thank, and something more, to Laura, for being always therefor me, despite the distance and the difficulties. We made it so far and I lookforward for what the future holds for us.
Finally the most important thank-you of all, to my family. Thanks tomy mum, Margherita, for worrying just enough, thanks to my dad, Antonio,for always taking care of us, thanks to my sister Marta, for putting up witha brother like me. Thank you a lot, thanks for your support and for beingalways there for me.
I hope I did not forget anyone. In that case just forgive me, blame thethesis submission anxiety, and, if we end up in a pub together, the first pint ison me.
Davide
15
Chapter 1
Introduction
1.1 Introduction
Laser technology provides the foundation for attosecond science. The develop-
ment of intense femtosecond lasers has unlocked the generation of attosecond
pulses via the process of high harmonics generation [1, 2]. These attosecond
pulses are a powerful tool to investigate dynamics at the edge of known time
scales [3]. The experimental developments both in the generation and the char-
acterisation of attosecond pulses have allowed scientists to perform time re-
solved experiments that challenge the theoretical models developed to describe
light-matter interactions. Pump probe have been used to study photoionisation
and tunnelling dynamics [4] confirming existing models [5], but also discover-
ing new effects like a delay in photoemission from different electronic states [6,
7].
Currently, one of the driving aspects of research in attosecond science is to
apply the techniques and knowledge gained in atomic systems to more com-
plex systems, such as molecules [8–10] and even condensed phase matter [11,
12]. The challenge is both technical and theoretical. Performing experiments
in atoms allowed an understanding of both the experimental technique and
the physical system under investigation thanks to well developed theoretical
models such as the strong field approximation for a single atom [13].
16 CHAPTER 1. INTRODUCTION
When moving to molecular systems the theoretical modelling is more com-
plicated. To begin with the geometry of the molecule has to be taken into ac-
count [10] with challenges that are not present in the atomic case. The molecule
geometry and the delocalised electronic structure makes the electron-electron
interaction important especially when the molecule is in a excited state [14].
To help deconvolve all these dynamics the experiments should be designed
to isolate a specific feature of the process under investigation. The stability
requirements and specifications of the experimental setup are therefore more
demanding to allow the acquisition of a reliable data set of sufficiently high
quality for the comparison with theoretical models. For this reason there is
great interest both in the development of new attosecond sources, able to spec-
trally target specific dynamics, and of new methods and techniques to increase
the amount of information that can be gathered from an experiment.
Regarding the development of new methods for attosecond science, an im-
portant topic is the characterisation of ultrafast pulses [15]. The precise knowl-
edge of the pulses applied to the experiment is vital to fully understand the
dynamics studied. On one hand rapid and easy to use diagnostics are ideal
for regular monitoring of the pulses, but on the other hand more sophisticated
techniques are required for a detailed characterisation of the pulse. In fact,
with the advent of extremely short femtosecond pulses [16], the characterisa-
tion of the exact waveform is required since pulses with the same envelope can
be significantly different. For these reasons techniques such d-scan [17] aim
for simplicity, while others like the petahertz oscilloscope [18] aim for carrier
waveform precision.
Moving to the field of development of new attosecond sources, it can be said
that the production of isolated attosecond pulses using an intense near-infrared
(NIR) femtosecond pulse has in the last decade become a well established and
understood process [3]. The development of this method has extended many
limits of attosecond pulses, from the highest photon energy reached (1.4 keV
[19]), to the shortest attosecond pulse measured (67 as [20]). These impressive
CHAPTER 1. INTRODUCTION 17
parameters are a demonstration of how far attosecond science has developed
since its beginning, but much is left to do in order to make attosecond sources
more versatile and readily accessible to the scientific community.
One essential requirement to extend the capabilities of attosecond science is
the development of attosecond pulses across different photon energies [19, 21]
to be applied to attosecond-pump attosecond-probe experiments. Most of the
existing schemes cannot produce attosecond pulses with enough photons to be
split and used in a pump-probe experiment (with few exceptions [22]). For this
reason the driving NIR field is often used with the attosecond pulse for pump-
probe. However the high NIR intensity can distort the observed dynamics and
its longer time duration lowers the time resolution of the experiment. To reach
different photon energies, different methods are being studied, from the use of
monochromators [23], to new HHG sources like ablation plumes [24]. Pulses
at low photon energies (few eV) are good candidates for the excitation step of
small molecules due to their high cross section in this spectral range [25]. Such
pulses can be used at relatively low intensity to drive single photon transition,
allowing significant simplifications in the understanding and modelling of the
exciting step of the experiment. Low order non linearities (including non linear
processes in photonic crystal fibres) have been exploited to generate pulses
with 4-7 eV photon energy and 3-18 fs pulse duration [26–29]. High harmonics
generation is a promising strategy to shorten the pulse duration and attosecond
pulses have been measured at this photon energy [21, 30]. However, the task of
delivering two independent and stable attosecond pulses to an experiment is
still extremely challenging and has been the main reasearch goal of this thesis.
18 CHAPTER 1. INTRODUCTION
1.2 Author’s contribution
I played a key role in the work presented in this thesis, as a part of a team
with Dr. T. Witting, Dr. F. Frank, Dr. W. Okell, Dr. T. Barillot and with Z.
Abdelrahman, D. Walke and P. Matia-Hernando.
For the results on the VUV pulse measurements I was, together with Dr.
T. Witting, the main researcher responsible for the attosecond streaking mea-
surement of the simultaneously generated VUV and XUV pulses. I carefully
optimised the laser system for these experiment and obtained the streaking
traces. I developed the LSGPA algorithm code for the analysis of the traces.
With fellow PhD students P. Matia-Hernando and D. Walke I optimised the
procedure for the photon flux calibration of the VUV pulses and gathered the
relevant data-sets. With J. Henkel and Dr. M. Lein (Institut fur Theoretische
Physik and Centre for Quantum Engineering and Space-Time Research, Leib-
niz Universitat Hannover) we interpreted the results of the TDSE simulations
and compared them with the experimental data.
I was closely involved in the data collection of the experimental campaign
led by Dr. W. Okell, studying the performance of the hollow core fibre CEP
stability.
I operated the laser system and assisted with the data acquisition during
the experimental campaign, led by PhD student Z. Abdelrahman, dedicated to
the spatial coherence characterisation of high harmonics generated in ablation
plumes.
Together with Dr. M. Siano I simulated the electrodes geometry for the
design of the electron VMI and ion TOF in close collaboration with Dr. T.
Barillot and D. Walke.
I performed the calculations related to the design of the single shot d-scan
and I participated with Dr. T. Witting to the experimental campaign in Porto
in collaboration with W. Holgado (University of Salamanca), Dr. F. Silva
(ICFO) and Prof. H. Crespo (Porto University).
CHAPTER 1. INTRODUCTION 19
Together with Dr. T. Witting I was involved in the experimental campaign
that led to the development of the ARIES technique in collaboration with Dr.
A. Wyatt (Science and Technology Facilities Council Rutherford Appleton
Laboratory) who performed the data analysis and with A. Schiavi and Prof I.
Walmsley (Oxford University).
1.3 Author publications
• Prediction of attosecond light pulses in the VUV range in a
high-order-harmonic-generation regime
J. Henkel, T. Witting, D. Fabris, M. Lein, P. L. Knight, J. W. G. Tisch,
J. P. Marangos
Physical Review A 87.4 (Apr. 2013), p. 043818. [31]
• Carrier-envelope phase stability of hollow fibers used for high-
energy few-cycle pulse generations
W. A. Okell, T. Witting, D. Fabris, D. Austin, M. Bocoum, F. Frank,
A. Ricci, A. Jullien, D. Walke, J. P. Marangos, R. Lopez-Martens,
J. W. G. Tisch
Optics Letters 38.19 (Oct. 2013), pp. 3918-3921. [32]
• Spatial coherence measurements of non-resonant and resonant
high harmonics generated in laser ablation plumes
R. A. Ganeev, Z. Abdelrahman, F. Frank, T. Witting, W. A. Okell,
D. Fabris, C. Hutchison, J. P. Marangos, J. W. G. Tisch
Applied Physics Letters 104.2 (Jan. 2014), p. 021122. [33]
• Synchronised pulses generated at 20 eV and 90 eV for attosecond
pump probe experiments
D. Fabris, T. Witting, W. A. Okell, D. J. Walke, P. Matia-Hernando,
J. Henkel, T. R. Barillot, M. Lein, J. P. Marangos, J. W. G. Tisch
Accepted for Nature Photonics
20 CHAPTER 1. INTRODUCTION
• Attosecond streaking on metallic films
W. A. Okell, T. Witting, D. Fabris, C. A. Arrel, J. Hengster, D. Y. Lei,
Y. Sonnefraud, M. Rahmani, D. Walke, S. A. Maier, S. Stankov, Th.
Uphues, J. P. Marangos, J. W. G. Tisch
Accepted for Optica
• Ultra-fast pulse characterisation with the d-scan technique: a
single shot implementation
D. Fabris, W. Holgado, F. Silva, T. Witting, H. Crespo, J. W. G. Tisch
In preparation for Optics Express
• Attosecond sampling of arbitrary optical waveforms (ARIES)
A. Wyatt, A. Schiavi, I. A. Walmsley, D. Fabris, T. Witting, J. P.
Marangos, J. W. G. Tisch
In preparation
21
Chapter 2
Theory and background
In this chapter I will introduce basic concepts related to ultra-fast lasers, their
characterisation and their interaction with matter.
2.1 Ultrafast lasers
Time resolved measurements have entered the attosecond domain due to the
huge improvements in ultrafast laser technology. The unique properties of such
pulses allow very high intensities to be reached, where non-linear processes can
be exploited to generate even shorter pulses reaching the XUV spectral range,
and to probe dynamical systems on very short time scales. This section will
introduce some of the most important concepts to describe and understand
ultra-fast pulses. The mathematical notation to describe broadband pulses
will be presented, allowing us to describe the effect that dispersion has on
such broadband pulses and to introduce the first concepts of non-linear optics.
2.1.1 Mathematical description
When only the time dependence of the electric field is considered (i.e. the
pulse is linearly polarised and spatially uniform) equations (2.1) and (2.2) can
22 CHAPTER 2. THEORY AND BACKGROUND
be used to describe a laser pulse in the spectral and temporal domains.
E (ω) =∣∣∣E(ω)∣∣∣ · eiϕ(ω), (2.1)
E(t) = |E(t)| · eiϕ(t). (2.2)
Assuming a linearly polarised pulse, only one component is necessary to de-
scribe the temporal profile of the pulse, while for an arbitrary polarised pulse
the full 2D description (Ex, Ey) is necessary. The two definitions provided in
the time and spectral domain are related by the Fourier transform:
E (ω) = F [E (t)] =1√2
∫ ∞
−∞E (t) eiωtdt
E(t) = F−1[E (ω)
]=
1√2
∫ ∞
−∞E (ω) e−iωtdω
(2.3)
This Fourier relation between time and frequency prescribes that a short
pulse in the time domain has a broad spectrum. For a given pulse shape
the spectral width Δν and the corresponding temporal width Δτ , are related
according the time bandwidth product (TBP):
ΔνΔτ ≥ a (2.4)
The constant a is specific for a given pulse shape assumed and the equality in
equation (2.4) is obtained only for a flat spectral phase ϕ(ω). In the case of
a Gaussian intensity profile ΔνΔτ = ln(4)/π ≈ 0.441. So for a given spectral
bandwidth the TBP can be used as an initial estimate for the possible pulse
duration. The assumption of a flat ϕ(ω) is however a strong one, especially
for broadband spectra such as those involved in the generation of ultra-short
pulses. For the characterisation of such pulses, therefore, both spectral am-
plitude and phase should be measured. Usually the spectral intensity I(ω)
of a visible or NIR pulse can be easily measured and related to the spectral
amplitude as I(ω) =∣∣∣E (ω)
∣∣∣2. The measurement of the spectral phase ϕ(ω)
CHAPTER 2. THEORY AND BACKGROUND 23
is, on the other hand, a challenging task and will be covered in more detail in
section 2.2.
A full description of a laser beam includes the spatial properties as well.
As a first approximation it is possible to decouple the temporal structure of
the pulse from the spatial properties:
E(x, y, z, t) = f(x, y, z)g(t) (2.5)
Here f(x, y, z) represents the spatial properties of the pulse, while g(t) the
temporal ones. Considering the spatial properties of an electromagnetic wave it
is possible to find a solution to Maxwell’s equations that corresponds to a beam
with a Gaussian transverse field distribution that, in cylindrical coordinates
(z, r), with z being the propagation axis, can be expressed as [34]:
E (r, z) =E0w0
w(z)exp
(− r2
w(z)2
)exp
{−i[kz − tan−1
(z
zR
)+
kr2
2R(z)
]}. (2.6)
Figure 2.1 shows the properties of such a beam.
The beam radius is defined as w(z) = w0
√1 + (z/zR)
2, with the Rayleigh
length zR = πw20/λ or the confocal parameter b = 2zR defining the beam
collimation. In fact the Rayleigh range represents the distance from the focus
where the beam area is twice the beam area at the focus. Therefore, considering
a beam path of length L, if b � L the beam can be considered collimated.
The beam radius at focus (z = 0) is w0, while k is the wave-vector k = 2π/λ
and R(z) is the radius of curvature of the wave-fronts R(z) = z(1 + z2r/z2).
A Gaussian beam can be completely described with the complex factor q(z)
[34] as follow:
E(z, r) ∝ exp
[−i πr
2
λq(z)
]with
1
q(z)=
1
R(z)− i
λ
πw2(z)(2.7)
24 CHAPTER 2. THEORY AND BACKGROUND
-3 -2 -1 0 1 2 3
-4
-2
0
2
4
-0.5
0
0.5
1
Figure 2.1: Properties of a Gaussian beam. The black line shows the beam radiusw(z) while the dashed lines show the wave front curvature.
This parameter is useful as it allows, following the matrix treatment of stan-
dard geometrical optics, the propagation of a Gaussian beam in space applying
the transformation matrices:
qout =Aqin +B
Cqin +D. (2.8)
It is then possible to compute, from the input Gaussian beam qin, the modified
Gaussian beam described by qout, once the matrix elements(A BC D
)of the optical
path the beam is going through are known.
In general, the temporal and spatial properties of a pulse can be coupled and
therefore the assumption made in equation (2.5) may not be valid. For example
different pulse durations can be measured at different spatial positions, due to
a non spatially uniform distribution of the frequencies of the pulse spectrum.
CHAPTER 2. THEORY AND BACKGROUND 25
2.1.2 Dispersion
A laser pulse will be now described from the spectral point of view, dropping
the tilde notation for convenience. From the definition in (2.1) the complex
phase ϕ(ω) can be expanded around the central frequency ω0 of the spectrum
|E(ω)| in a Taylor series:
ϕ(ω) =∞∑n=0
1
n!ϕn (ω − ω0)
n =
=ϕ0 + ϕ1 (ω − ω0) +ϕ2
2!(ω − ω0)
2 +ϕ3
3!(ω − ω0)
3 + . . .
(2.9)
The ϕn terms describe the effect of dispersion on a pulse, i.e. the fact
that waves of different frequencies travel at different velocities in a medium.
The first term is known as the carrier envelope phase (CEP). It is of particular
interest in few-cycle pulses, where the field envelope has a duration comparable
to the optical period (T = 2π/ω0). It gives the phase offset between the
maximum of the envelope and the maximum of the carrier as shown in figure
2.2.
Fiel
d S
treng
th (a
rb. u
.)
-1
-0.5
0
0.5
1 (a)
Time (fs)-5 -4 -3 -2 -1 0 1 2 3 4 5
Inte
nsity
(arb
u.)
0
0.2
0.4
0.6
0.8
1 (b)
Figure 2.2: Effect of different CEP’s in the waveform of a few cycle pulse. Goingfrom a cos-like pulse (ϕ0 = 0 dashed blue), to a sin-like pulse ϕ0 = π/2 changes themaximum field strength reached (a) and instantaneous intensity (b).
26 CHAPTER 2. THEORY AND BACKGROUND
The peak of the carrier slips with respect the peak of the field envelope by
a quarter of the fundamental period when the CEP is changed from ϕ0 = 0 to
ϕ0 = π/2. This not only changes the maximum instantaneous field strength
and intensity, with a drop in field strength of 4.2% and in intensity of 8.2%
(assuming a pulse duration of 1.45 cycles), but also changes the temporal
symmetry of the pulse, going from an isolated peak in the case of ϕ0 = 0,
where the secondary peaks are 29% lower in intensity, to the situation of two
equal peaks when ϕ0 = π/2. These differences have a great impact in the
highly non-linear processes discussed in this thesis.
The second term in the spectral phase Taylor expansion is ϕ1 = dϕdω
∣∣ω=ω0
also known as group delay (GD). This term describes a translation in time
of the pulse, as it adds a pure phase factor that is linear in frequency. This
does not affect the pulse duration, but should be taken into account when
temporal overlap between two pulses is required, for example in pump-probe
experiments.
The next term in the expansion is ϕ2 = d2ϕdω2
∣∣∣ω=ω0
, called the group delay
dispersion (GDD). Being the derivative of the GD with respect to frequency, it
represents how much the arrival time of a given frequency component changes
with respect the others. Most materials have a positive GDD in the wave-
length region of interest (visible to NIR), therefore a positive GDD is defined
as “normal”: red components of the spectrum travel faster than the blue ones.
A negative dispersion is defined as “anomalous”. The effect of GDD is usually
defined for a given material via the group velocity dispersion (GVD). The spec-
tral phase accumulated by the pulse passing through a length L of a medium
is ϕM(ω) = k(ω)L. Taking the second derivative with respect frequency to
compute the GDD gives:
GDD =d2ϕM(ω)
dω2
∣∣∣∣ω=ω0
=
(d2k(ω)
dω2
∣∣∣∣ω=ω0
)L = (GVD)L (2.10)
CHAPTER 2. THEORY AND BACKGROUND 27
In terms of the refractive index of the medium, the GVD and the following
term known as third order dispersion (TOD) can be written as:
GVD =λ3
2πc2d2n
dλ2
TOD = − λ2
4π2c3
(3λ2
d2n
dλ2+ λ3
d3n
dλ3
) (2.11)
The phase accumulated, however, cannot be solely described in terms of
GVD and TOD, and the higher order terms are generally summarised with
the Sellmeier equation:
n(λ) = 1 +∑i
Biλ2
λ2 − Ci
(2.12)
The effects of dispersion on a few cycle (3.6 fs at 800 nm) pulse are shown
in figure 2.3.
1 1.5 2 2.5 3 3.5 40
5
10
15
20(a)
Time (fs)-20 -15 -10 -5 0 5 10 15 20
Inte
nsity
(arb
. u.)
0
0.2
0.4
0.6
0.8
1 (b)
Figure 2.3: The effects of different amount of dispersion in a 3.6 fs pulse. Thespectrum (solid black line) and different phases are shown in (a). the respectivetemporal profiles are shown in (b). Note how the 1 m path in air can broadensignificantly the pulse (magenta dashed line).
28 CHAPTER 2. THEORY AND BACKGROUND
When only ϕ0 and ϕ1 are present, the pulse is defined as Fourier Transform
Limited (FTL), because the shortest pulse duration possible is achieved with
the given spectrum. Any additional phase term broadens and modifies the
temporal profile. Note how a beam path of 1 meter in air broadens a 3.6 fs
pulse (with spectrum centred at 800 nm) to 13.6 fs.
It becomes evident that phase compensation of air path, vacuum windows
and optics, is required to deliver a short pulse to an experiment. Different
pulse compressor and pulse stretcher designs have been developed to remove or
introduce phase to a pulse. Most common are prism [35] and grating [36] based
stretchers and compressors, where spatially separating the spectral components
of a pulse allows a frequency dependent path length through the system. Figure
2.4 shows how these elements can be set up to introduce negative and positive
dispersion.
Lp
Lg
(a)
(d)(c)
(b)
Figure 2.4: Example of prism and grating stretchers (a), (c) and prism and gratingcompressors (b), (d). See equation (2.13) for an expression of the GDD provided bythe compressors shown.
CHAPTER 2. THEORY AND BACKGROUND 29
The tuning of the dispersion can be performed by adjusting the separation
of the prisms or the gratings. Usually gratings set-ups are able to provide
more dispersion than prisms set-ups of similar size, but the two have different
signs for the TOD that is positive for a grating compressor, and negative for a
prism compressor. For this reason they can be used in series to achieve close to
zero GDV and TOD at the same time. When considering compressors, other
than their phase range and dimensions, a critical constraint is related to the
maximum intensity they have to withstand. In this aspect, a reflective grating
compressor can perform better than a prism compressor because the pulse does
not travel through the material of the compressor but it is simply reflected.
The full characterisation and analytical description of such devices is difficult,
as the temporal and spatial properties of the pulse are now coupled. For beams
with small beam size and symmetric (perfectly aligned) compressors set-ups
the following equations can be used [35, 36].
GDDprism =λ3
2πc24Lp{[
d2n
dλ2+(2n− n−3
)(dndλ
)2]sin β − 2
(dn
dλ
)2
cos β
}
GDDgrating = − λ3Lg
2πc2d2
[1−(λ
d− sin θi
)2]−3/2
,
(2.13)
where grating and prism separation is Lg and Lp respectively. The parameter
β is the spread angle after the first prism between the highest and lowest
frequency in the pulse, usually small enough that the approximation sin β ≈ 0
and cos β ≈ 1 is valid. The parameter d is the grating period and θi is the
angle of incidence of the incoming beam with respect the grating normal.
Other devices exist for the phase manipulation of a pulse that do not rely on
spatially dispersing the beam. It is possible to design chirped mirrors [37, 38],
a stack of dielectric materials of varying thickness such that the penetration
depth of different wavelengths varies introducing negative dispersion as shown
in figure 2.5. Another approach for phase manipulation is to use the coupling
30 CHAPTER 2. THEORY AND BACKGROUND
between acoustic and optical waves in a birefringent medium. If different
wavelengths travel for different lengths on each axis, they will accumulate
different phases at the end of the birefringent medium. An acoustic wave
launched into the birefringent crystal creates a density-induced grating able
to diffract, at different spatial positions, different wavelengths onto the other
optical axis of the birefringent crystal [39]. In this way, as shown in figure 2.5,
it is possible to slow down the red components (fast) on the slow axis while
the blue components (slow) still travel on the fast axis.
fast
slow
acousticwave
(a)
(b)
birefringent medium
Figure 2.5: Chirped mirror (a), and Dazzler (b) concepts for inducing negativedispersion. The chirped mirrors are manufactured such that different wavelengthsare reflected at different depths. In a Dazzler an acoustic wave is used to coupledifferent wavelengths onto the fast/slow axis of a birefringent medium at differenttimes. In this way the optical path length of different frequencies can be manipu-lated. In figure is shown how the red components of a pulse can be slowed downwhen allowed to travel on the slow axis longer than the blue components.
CHAPTER 2. THEORY AND BACKGROUND 31
2.1.3 Non-linear optics
With the strong optical fields available from lasers it is possible to induce a
non-linear response in the polarisation of a medium. Maxwell equations for
the electric and magnetic fields E and B with the only current component due
to the polarisation of the medium P can be written as:
∇ · E = 0 (2.14a)
∇× E = −∂B∂t
(2.14b)
∇ ·B = 0 (2.14c)
∇×B =1
c2∂E
∂t+ μ0
∂P
∂t(2.14d)
From these equation the wave equation can be obtained:
∇2E− 1
c2∂2E
∂t2= μ0
∂2P
∂t2(2.15)
So far no specific assumptions have been made, however to find the solutions
of equation (2.15) the relation between E and P has to be established. In the
usual case of a linear relation:
P = ε0χ(1)E, (2.16)
the usual plane wave solution is found together with the introduction of the
refractive index n =√1 + χ(1) = c/v, where v is the speed of the wave in
the medium and χ(1) is the linear susceptibility of the medium. In this linear
regime no new frequencies are generated, so when the system is driven at
frequency ω0, the polarisation field P will still be at frequency ω0 with only a
difference in speed. However this is just a first approximation, and due to the
high intensities achievable with lasers, a non-linear response of the medium can
32 CHAPTER 2. THEORY AND BACKGROUND
be expected and therefore (2.16) should be expanded to higher order terms:
P = ε0[χ(1)E+ χ(2)E2 + χ(3)E3 + · · · ] (2.17)
When non-linear terms are introduced in the response of a system, new fre-
quencies can be created. In fact assuming the driving electric field to be:
E(t) = E1 exp(iω1t) + E2 exp(iω2t) + c.c. (2.18)
the second order response of the medium can be written as:
E2(t) =E21 exp(i2ω1t) + c.c.
+ E22 exp(i2ω2t) + c.c.
+ 2E1E2 exp[i(ω1 + ω2)t] + c.c.
+ 2E1E∗2 exp[i(ω1 − ω2)t] + c.c.
+ 2|E1|2 + 2|E2|2
(2.19)
In equation (2.19) are present frequencies that were absent in equation (2.18).
The new terms corresponds to the second harmonics of the fundamental fre-
quencies (2ω1 and 2ω2), and to their sum and difference frequencies (ω1 ±ω2).
It is possible to describe such phenomena in the photon picture as shown in
figure 2.6, where arrows pointing upwards are photons absorbed, and arrows
pointing downwards are photons emitted. The higher the order considered,
the more photons are involved in the process, and the less likely is the process
to happen.
Figure 2.6: Non linear optics processes depicted as multiple photon interactions.
CHAPTER 2. THEORY AND BACKGROUND 33
Let us focus on second harmonic generation (SHG), that allows me to in-
troduce concepts useful in general in non-linear optics. The non-linear relation
between E and P makes finding the solution to equation (2.15) more difficult.
The first approximation usually introduced is the low depletion approxima-
tion where the input field E is assumed not to be perturbed by the non-linear
process occurring. In the case of SHG this means that the energy transfer be-
tween the fundamental frequency and the second harmonic is negligible, and
only equation (2.15) for the field at 2ω0 needs to be considered. The slowly
varying envelope approximation is usually made as well, where the field enve-
lope is assumed to be varying slowly both in time and space:
∂2E2ω0
∂t2� 2ω0
∂E2ω0
∂t
∂2E2ω0
∂z2� k2ω0
∂E2ω0
∂z(2.20)
With these assumptions, equation (2.15) can be written, in a co-moving frame,
propagating along z, in the form:
∂E
∂z= −iμ0ω
2
2kP exp(iΔkz) (2.21)
The Δk factor, called the phase mismatch factor, represents the difference
between the wave-vector at the frequency under investigation k2ω0 = 2ω0/v =
2ω0n(2ω0)/c and the wave-vector of the polarisation induced kpol = kω0+kω0 =
2ω0n(ω0)/c. The solution to equation (2.21) integrating over a length L is:
E2ω0 = −iμ0(2ω0)2
2k2ω0
P2ω0L exp
(iΔkL
2
)sinc
(ΔkL
2
)(2.22)
from which the intensity can be written:
I2ω0 ∝ |P2ω0 |2L2 sinc2(ΔkL/2) (2.23)
The coherent length, Lcoh = π/Δk, can be now introduced, and the meaning
of phase-matching understood. The production of the non linear signal in fact
34 CHAPTER 2. THEORY AND BACKGROUND
strongly depends on Δk. When Δk = 0 the intensity of the second harmonic
grows quadratically with length. When Δk = 0 the output signal is reduced
and has maxima and minima with periodicity Lcoh as shown in figure 2.7.
0 1 2 3 4 5 6
Figure 2.7: Second harmonic generation phase-matching happens when Δk = 0,while the bigger Δk, the lower and more oscillating the signal is.
In the case of SHG the phase-matching condition can be written as
k2ω0 = 2kω0 i.e. n(ω0) = n(2ω0) (2.24)
This condition is usually prohibited by dispersion. However phase-matching
conditions can be met, for example with birefringent material using no(2ω0) =
ne(ω0), or other phase matching techniques [40].
Another important effect is the Pockels effect (a second order or χ(2) effect),
where a DC field can induce birefringence in an otherwise non-birefringent
crystal. In this way it is possible to switch on and off a quarter wave plate
rapidly, using pulsed voltages, in a device known as “Pockels cell”.
Important χ(3) processes include self phase modulation (SPM) and Kerr-
Lensing, that can be described as the effect of a non-linear refractive index in
time (SPM) and space (Kerr-lensing):
n(r) = n0 + I(r)n2 (Kerr-lens)
n(t) = n0 + I(t)n2 (SPM)(2.25)
CHAPTER 2. THEORY AND BACKGROUND 35
In the case of Kerr-lensing, the effect for an intense beam with a Gaussian
profile is self-focusing. In fact the the intensity profile curvature in space, I(r),
will result in an effective refractive index curvature, with the central region of
the beam experiencing a stronger refractive index than the outer part and
therefore experiencing the same effects of a focusing optic. This effect can
lead to a self-sustaining feedback as the intensity will increase due to the self-
focusing, and may lead to damage to the non-linear medium. On the other
hand this mechanism can be usefully applied to achieve mode-locking.
In the case of SPM, the temporal phase accumulated through a non-linear
medium of length z can be computed as ϕ(t, z)SPM = k0n2I(t)z. In the same
way that a spectral phase can broaden the temporal profile of a pulse without
changing the spectral amplitude, a temporal phase can broaden the spectral
profile without changing the temporal shape. This can be exploited to spec-
trally broaden a pulse in order to support shorter pulse durations, as shown
in figure 2.8.
(a)
0 0.5 1
1.52
2.53
3.51.5 2 2.5 3 3.5
Inte
nsity
(arb
. u.)
0
0.5
1(b)
(c)
0 0.5 1
-50
0
50-50 0 50
Inte
nsity
(arb
. u.)
0
0.5
1(d)
Figure 2.8: Spectral broadening due to self-phase modulation. In (a) the spectralprofile is plotted as a function of propagation. In (c) the corresponding FTL tem-poral profile of (a) is shown. In (b) and (d) the detail of the computed profiles atbeginning (red) and at the end (dashed black) of the propagation through he nonlinear medium are shown.
36 CHAPTER 2. THEORY AND BACKGROUND
In this case, a 30 fs pulse intensity profile has been used, and it can be noted
how, with propagation along L, new frequencies are generated by comparing
the line-out at the beginning (solid red) with the line-out at the end (dashed
black) in panel (a) and (b). If these frequencies are compressed appropriately
they can result in short pulses as shown in panels (c) and (d), where the FTL
temporal profile has been computed. This process is harnessed in hollow fibre
pulse compression that will be discussed in 3.2 which is the main method to
produce intense few cycle pulses.
2.1.4 Short pulse production
To obtain a pulse duration in the femtosecond range the required bandwidth
needs to span a range of tens of nanometres. For example a 30 fs pulse at
800nm requires a bandwidth of ≈30 nm. A gain medium capable of providing
such bandwidth is Titanium doped Sapphire (Ti:Sapphire) [41]. The modes
inside a laser cavity are the longitudinal modes with wavelength:
λn =2Lc
n(2.26)
where Lc is the laser cavity length and the integer n is the mode number. To
achieve short pulse durations the intra-cavity dispersion has to be compensated
so that the cavity modes can interfere to generate a short pulse once their
phases are locked, as explained in figure 2.9.
This procedure is called mode-locking [42, 43] and is usually achieved ex-
ploiting the Kerr-lensing effect [44]. Self-focusing can be exploited to spatially
select only intense pulses as shown in figure 2.10. When soft Kerr-lensing is
applied there is no physical aperture, but the focusing geometry and the os-
cillator cavity are designed so that only the more intense part of the beam,
undergoing self focusing, is overlapped with the pump beam. In this way the
mode locked, shorter and therefore more intense pulses are selected and am-
plified. This process can usually be initiated by a noise spike [45, 46] obtained
CHAPTER 2. THEORY AND BACKGROUND 37
Mode number-25 -20 -15 -10 -5 0 5 10 15 20 25
Pha
se (r
ad)
0
2
4
6
8Modes Amplitude=1Random phaseLocked phase
Time (fs)-60 -40 -20 0 20 40 60
Inte
nsity
(arb
. u.)
0
0.5
1Random PhaseLocked Phase
Figure 2.9: Mode locking effect. If the phase of a set of modes is random (bluecircles), the overall signal will be spread in time and will result in a CW emission. Ifthe phase of the modes is locked (black crosses), constructive interference producesan isolated strong pulse.
by a quick movement of one of the optical components in the laser cavity (e.g.
by tapping it). This spike starts a positive feedback process that leads to the
mode-locked operation of the oscillator. With this technique oscillator pulses
as short as 4.4 fs have been produced [47].
The typical oscillator output, with only few nJ per pulse, can be amplified
to the millijoule level via chirped pulse amplification [48]. A direct amplification
of the short oscillator pulses will lead to damage of the optical components due
to self focusing. To prevent this occurrence the pulses are dispersed, or chirped,
non-linear medium
Intense pulseamplified
Figure 2.10: Kerr-Lens Mode-Locking concept: the intense part of the beam isfocused (red profile) and the optical designof the oscillator naturally favours theintense pulses with optimal overlap with the pump beam represented by the greenarea.
38 CHAPTER 2. THEORY AND BACKGROUND
before amplification. In this way the pulses are stretched in time and the peak
power is lowered allowing the amplification step to happen without damaging
the system. Once amplification has occurred, the pulse can be compressed once
again and delivered to the experiment. Figure 2.11 shows the CPA technique.
stretcher
amplifier
compressor
Figure 2.11: Chirped pulse amplification. The pulse to be amplified is stretchedin time in order to lower the peak power. Once amplification has occurred the pulsecan be compressed once again.
The mechanism of chirped pulse amplification heavily relies on the accurate
phase dispersion compensation after amplification, from which the importance
of stretchers and compressors introduced in figure 2.4 appears clear. During
amplification other effects have to be taken in account, for example gain nar-
rowing can limit the amplification of the full bandwidth available from the
oscillator pulses. In fact the amplification process is not homogeneous for
different wavelengths [41], and the gain curve of the amplifying medium is
imprinted onto the spectrum of the output pulse.
Ti:Sapphire CPA systems are nowadays commercially available and can
provide pulses with a duration of ≈ 30 fs and pulse energy in the multi-
millijoule level. With these parameters, peak powers in the TW (1012 W) level
are easily achievable, giving access to the high harmonics generation (HHG)
process (see section 2.3), at the base of attosecond science.
CHAPTER 2. THEORY AND BACKGROUND 39
2.2 Characterisation techniques
Pulse characterisation in the ultra-fast domain can be challenging since both
spectral amplitude and phase of the pulse have to be measured accurately.
A direct measurement in the time domain is not possible because electronics
detectors (i.e. photodiodes) usually have a response time in the nanosecond
range, so are not suitable for femtosecond pulses. In the spectral domain it
is relatively easy to obtain the spectrum of a pulse with a spectrometer, as
shown in figure 2.12, but no spectral phase is recorded. Most ultrafast pulse
characterisation techniques rely on using the pulse to measure itself. In the
following sections some characterisation techniques will be discussed.
dete
ctor
input beam
grating
M
M
Figure 2.12: Typical spectrometer device, providing I(ω). A dispersive element,usually a grating, spatially separates the wavelengths components of the pulse thatare then imaged onto a detector, for example a CCD array.
2.2.1 Autocorrelation
The signal measured from an ideal slow detector can be written as:
Vsig =
∫ ∞
−∞|E(t)|2dt (2.27)
The simplest idea to measure the pulse with itself is to send two replica
of the pulse onto the detector and measure the signal as a function of delay
between the two, as shown in figure 2.13.
40 CHAPTER 2. THEORY AND BACKGROUND
BS
delaystage
detector
Figure 2.13: Field autocorrelation set-up. Two replica of the pulse are createdwith a beam splitter. A simple translation stage provides the delay between the twopulses that are then recombined on the detector.
Vsig(τ) =
∫|E(t) +E(t− τ)|2dt = const. + 2
{∫E(t)E∗(t− τ)dt
}(2.28)
This method is known as field autocorrelation and the measured signal can
be expressed as in equation (2.28). The measured constant level is proportional
to the pulse energy, while the remaining delay dependent term is oscillatory,
but contains only the spectral amplitude information as shown in figure 2.14.
Inte
nsity
(arb
. u.)
0
0.5
1(a) FTL
40 fs3
time (fs)-20 -15 -10 -5 0 5 10 15 20
Vsi
g (arb
. u.)
-1
-0.5
0
0.5
1(b)
Figure 2.14: Field autocorrelation trace, no phase information is retrieved, aswhen the two pulses share the same amplitude but different phase, as shown in plot(a), the autocorrelation trace, shown in (b), is identical.
CHAPTER 2. THEORY AND BACKGROUND 41
The field autocorrelation has been computed for a FTL pulse and for a pulse
with identical spectral amplitude but with 40 fs3 chirp. Note how the two very
different temporal profiles in 2.14(a) provide the same field autocorrelation
trace in 2.14(b) due to the fact they share the same |E(ω)|.It is possible to go from field autocorrelation to intensity autocorrelation
by introducing a non-linear crystal and measuring the second harmonic rather
than the direct beam, as shown in figure 2.15.
SHG
BS
detector
delaystage
Figure 2.15: Intensity autocorrelation setup. The spatial selection of the middlebeam after SHG allows to measure the required signal.
Vsig(τ) =
∫|E(t)|2 · |E(t− τ)|2dt (2.29)
In this case the measured signal will be expressed as in equation (2.29).
The signal is not oscillating, and provides an envelope that can be related to
the pulse intensity envelope I(t) = |E(t)|2. If a Gaussian intensity profile is
assumed, it is possible to compute the factor between the trace width and
the pulse width as Δτautocorr/Δτpulse = 1.41. The trace is always symmetric
in time, so the time direction has to be deduced from the geometry of the
experimental setup. However little information about the spectral phase can
be retrieved with this method, as is shown in figure 2.16.
It can be seen how the intensity autocorrelation traces in 2.16(b) are very
similar, despite the chirp of the pulses being very different as shown in 2.16(a).
This technique can be used as a first estimate of the pulse duration for sim-
ple intensity profiles, for example when a Gaussian profile can be assumed,
and when dispersion is not affecting the pulse duration too much. For more
42 CHAPTER 2. THEORY AND BACKGROUND
Inte
nsity
(arb
. u.)
0
0.5
1(a) 6 fs2
40 fs3
time (fs)-20 -15 -10 -5 0 5 10 15 20
Vsi
g (arb
. u.)
0
0.5
1(b)
Figure 2.16: Intensity autocorrelation for two pulses sharing the same spectrumbut with different phase as shown in (a). Note how the autocorrelation trace, shownin (b), is very similar in the two cases.
complicated pulses, intensity autocorrelation can lead to ambiguous results
[49].
It is possible to obtain an interferometric autocorrelation trace [50] by
combining two collinear replica of the pulse on the SHG crystal. The trace
measured with this method can distinguish between almost identical intensity
autocorrelation traces, especially if appropriate filtering and analysis of the
trace is applied [51, 52]. However a precise measurement of the spectral phase
of the pulse, in the few-cycle regime, is not possible with these techniques [53],
and even increasing the order of the non linear process exploited to obtain the
measured trace does not yield substantial improvements to this approach [15].
2.2.2 Frequency Resolved Optical Gating
Frequency resolved optical gating (FROG) [53, 54] extends the idea of auto-
correlation, allowing for the retrieval of the spectral phase. The output of a
FROG device is a spectrogram, which is a 2-D map of frequencies (spectra) as
CHAPTER 2. THEORY AND BACKGROUND 43
a function of time (delay). For a signal E(t) and a gating function g(t) it can
be expressed mathematically as:
S(ω, τ) =
∣∣∣∣∫ ∞
−∞E(t)g(t− τ)eiωtdt
∣∣∣∣2 (2.30)
Figure 2.17 shows the spectrogram of a pulse with three different phases, using
a Gaussian gating function with 10 fs FWHM.
(d)(d)
time (fs)-40 -20 0 20 40
Freq
uenc
y (r
ad/fs
)
0
1
2
3
4
5
6(e)(e)
time (fs)-40 -20 0 20 400
1
2
3
4
5
6(f)(f)
time (fs)-40 -20 0 20 400
1
2
3
4
5
6
Am
plitu
de (a
rb. u
.)
-1
-0.5
0
0.5
1(a)
-1
-0.5
0
0.5
1(b)
-1
-0.5
0
0.5
1(c)
Figure 2.17: Spectrogram of three pulses with same spectrum and positive (a),negative (b) and without (b) chirp. The corresponding spectrograms were computedwith a 10 fs Gaussian gate, and are shown in (d), (e) and (f).
The differences of the three spectrograms (d),(e) and (f) for a positively
chirped pulse (a), a FTL pulse (b), and negatively chirped pulse (c), are clear.
Even if the gate is not much shorter than the actual pulse it is possible, for
example, to track the instantaneous frequency ω(t) as a function of time, show-
ing how the spectrograms yield useful information about the signal phase. The
unknown pulse can be used as the gate in equation (2.30), using the same op-
tical set-up as in figure 2.15, simply measuring the second harmonic spectrum
44 CHAPTER 2. THEORY AND BACKGROUND
generated at each delay. The measured signal can be expressed as [53]:
IFROG(ω, τ) =
∣∣∣∣∣∣∣∫ ∞
−∞
SHG︷ ︸︸ ︷E(t)E(t− τ)︸ ︷︷ ︸
g(t)
eiωtdt
∣∣∣∣∣∣∣2
(2.31)
In this case g(t) is an amplitude and phase gate at the same time and it is
unknown. While this seems like a dead end, having now a 2-D map allows
one to fully determine both the signal and gate function using a retrieval al-
gorithm. This is possible when at least the integrand of equation (2.31) is
known, i.e. when the interaction between g(t− τ) and E(t) is known. If this isthe case, a generalised projection algorithm (GPA) [55] can be used to apply
two constraints, one is the measured spectrogram, the other is the assumed
interaction between signal and gate. The algorithm modifies, in an iterative
fashion, amplitude and phase of both E(t) and g(t) to fulfil the imposed con-
straints. In this way, if the signal and gate are well behaved, the algorithm
will converge to a solution as shown in figure 2.18.
apply
apply
solutioninitial guess
Figure 2.18: Generalised Projection Algorithm (GPA). From an initial guess ofgate and signal, the measured intensity of the spectrogram, and the required gat-ing action are applied to iteratively improve the agreement between the measuredspectrogram and the retrieved one.
CHAPTER 2. THEORY AND BACKGROUND 45
2.2.3 Spectral Phase Interferometry for Direct Electric
field Reconstruction
Another approach to characterise ultra-short pulses comes from interferome-
try. Interferometry can be very sensitive to phase variation in signal and has
been applied to ultra-short pulses to gather information about the spectral
phase [15]. The idea is to make the ultra-short pulse interfere with a spectrally
sheared replica of itself, and from the interference pattern recorded extract
the spectral phase. This technique is called spectral phase interferometry for
direct electric field reconstruction (SPIDER) [56]. It is possible to achieve a
pulse replica shifted in frequency with a chirped pulse and SHG. A chirped
pulse has its frequency components smeared in time, so that, if a shorter pulse
is combined at different times in a non linear crystal, the second harmonic
will be produced at slightly different frequencies, as shown in figure 2.19 and
expressed in equation (2.32)
E1 = E(ω − ω0)eiϕ(ω−ω0) E2 = E(ω − ω0 − Ω)ei[ϕ(ω−ω0−Ω)+ωτ ] (2.32)
stretcher
SHG
Spectrom
eter
Figure 2.19: Standard SPIDER set-up. After splitting the beam, one arm of theinterferometer includes a stretcher, to provide the ancilla. In the other arm a delayedreplica of the pulse is produced, for example with a split mirror or an etalon. Suchpulses are then recombined for SHG resulting in two up-converted pulses at differentcentral frequencies. The resulting spectrum is measured on a standard spectrometer.
46 CHAPTER 2. THEORY AND BACKGROUND
The chirped pulse is generally referred to as the “ancilla” as it just serves
for shearing the two replica of the pulse under investigation. With such ar-
rangement the SHG measured on axis can be written as:
S(ω) = |E1 + E2|2 == |E(ω − ω0)|2 + |E(ω − ω0 − Ω)|2 + (DC term)
+ 2E(ω − ω0)E(ω − ω0 − Ω)· (2.33)
· exp [φ(ω − ω0)− φ(ω − ω0 − Ω) + ωτ ] . (AC term)
The phase term in equation (2.33) is an approximation of the derivative of
the wanted ϕ(ω), as it expresses the difference of phase in steps of width Ω. It
can be retrieved via Fourier filtering as shown in figure 2.20.
1 2 3 4 5 6 7 8
Inte
nsity
(arb
. u.)
0
0.5
1
1.5
2
2.5
0
(rad/ fs)
(a)
0.5 1 1.5 2 2.5 3 3.5 4
Inte
nsity
(arb
. u.)
0
0.5
Pha
se (r
ad)
-20
-15
-10
-5
0
5
10
15
20
(d)
FT
filteringand FT-1
integration&
shift
(rad/ fs)
-60 -40 -20 0 20 40 600
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
filter
(b)
Inte
nsity
(arb
. u.)
time (fs)
-100
0
100
3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 80
0.5
1
1.5
2
2.5
-1
-1
ang
(c)
phas
e (r
ad)
Inte
nsity
(arb
. u.)
(rad/ fs)
Figure 2.20: SPIDER analysis involving the Fourier transform of the interferencepattern measured in (a), to select the AC component in (b). Once the selection isperformed the inverse Fourier transform (c) provides the phase values from whichthe spectral phase can be reconstructed (d).
The interference pattern measured in the frequency domain (2.20(a)) is first
Fourier transformed. A peak around τ can be isolated from the DC component
(2.20(b)) and then Fourier transformed back in the frequency domain (2.20(c)).
CHAPTER 2. THEORY AND BACKGROUND 47
The obtained phase is the derivative of the spectral phase of the pulse, that
can be calculated by integration [57]. After shifting the measured phase and
spectrum to the original ω0 position the full amplitude and spectrum of the
pulse can be retrieved.
In our laboratory the optical characterisation of the few cycle pulse is usu-
ally performed either with the standard 1-D implementation of SPIDER, with
the stretcher consisting of a rod of BK7 and the two replica created on a split
mirror, or with the more sophisticated spatially-encoded arrangement with fil-
ters SPIDER (SEA-F-SPIDER) [58]. In this case, two ancillas are prepared
with narrow-band spectral filters and the two out-coming sheared replicas in-
terfere spatially as they are recombined at an angle. To record the spatial
fringes an imaging spectrometer is required, allowing the characterisation of
the pulse both in the temporal and spatial domains as shown in figure 2.21.
Figure 2.21: SEA-F-SPIDER. Interference of the two pulse replica is obtain bycombining them in the BBO crystal at an angle. The ancilla preparation is per-formed with angle tunable narrow bandwidth spectral filters. The signal treatmentis similar to the 1D SPIDER case. Figure reproduced from [58]. c©IOP Publishing.Reproduced by permission of IOP Publishing. All rights reserved.
48 CHAPTER 2. THEORY AND BACKGROUND
2.2.4 CEP measurement and stabilisation
The CEP can be extremely important in experiments involving intense few-
cycle lasers such as HHG. For this reason it is an important parameter to
measure and stabilise. The locking and stabilisation of the CEP begins in
the oscillator. The CEP would change on a shot to shot basis, even in a
perfect environment, without external contributions like temperature drifts or
mechanical vibrations, due to the difference between the phase velocity of the
carrier, and the group velocity of the pulse envelope. Each consecutive pulse
would therefore experience a CEP slip Δϕ0 that should be taken into account
and controlled to obtain a pulse train of CEP stable pulses. In fact if Δϕ0 =
2π/n each nth pulse will have the same CEP. While different experimental
methods are available to determine the CEP value, including stereo ATI [59]
and solid state detectors [60], the most common way to measure the CEP is
interferometry [61]. In figure 2.22 is shown the frequency comb corresponding
to the mode-locked pulse train. Each line is a longitudinal mode frequency,
and only those overlapping with the Ti:Sapphire gain curve are amplified.
Frequency
Inte
nsity
Gain BandwidthGain BandwidthGain Bandwidth
Figure 2.22: Spectral structure of a mode locked pulse train. Each line is alongitudinal cavity mode, and those corresponding to the gain medium gain curveare amplified. The separation between the modes is frep, while the offset f0 can bewritten as f0 = frepΔϕ0/(2π)
CHAPTER 2. THEORY AND BACKGROUND 49
Each frequency component can be written as [62] fn = nfrep + f0, with
f0 = frepΔϕ0/2π. If the frequency doubled part of the low frequency spectrum
interferes with the corresponding high frequency part one can obtain:
2fn − f2n = 2(nfrep + f0)− (2nfrep + f0) = f0 = frepΔϕ0/2π (2.34)
Therefore, measuring the beat note 2fn − f2n = f0 and frep allows one to
measure the CEP slip Δϕ0.
In order to stabilise the CEP of a pulse train the beat note obtained from
the f − 2f interferometer has to be locked to f0 = frepn. If this condition is
met, every nth pulse of the train has the same CEP. The locking procedure is
usually obtained with a feedback loop. Once f0 is measured it can be compared
to the wanted frequency, and the difference between the target frequency and
the measured one can be used as error signal in a PID controller. To act on
f0 it is necessary to have a fast actuator, able to modify f0 at a rate as fast
as the repetition rate of the laser system. An efficient method is to modulate
the power of the pump laser of the oscillator with an acousto-optic modulator
(AOM) [62] providing a satisfactory dynamic range and response time.
With this system only one every nth pulses can be used for CEP sensitive
experiments. Locking the beat note to frep would allow one to have a pulse
train with identical CEP at each pulse, but it is not experimentally practical
due to the difficulty in separating the signal coming from the beat note f0 and
the one coming from the input laser [63]. An elegant solution to this problem
has been proposed by Koke et al. [64] with a feed-forward scheme. In this
case the error signal is not fed back to the laser system, but is used to drive
an acousto-optic shifter to correct the output pulse, before delivery to the
experiment. This method allows to leave the laser system free-running, with
less stringent constraint on its stability, and provided a residual time jitter as
small as 12 as.
50 CHAPTER 2. THEORY AND BACKGROUND
2.3 Strong field physics
2.3.1 Ionisation
Einstein showed how, when light with sufficient photon energy (�ωL > W )
interacts with solids, photo ionisation occurs [65]. The photoelectric effect is
explained as the exchange of energy between light (�ωL) and the system (work-
function W ), so that when the potential barrier can be overcome, an electron
is created from a photon. If an atom is considered, rather than a solid, as the
target system, to a first approximation the work-function W will be replaced
by the ionisation potential Ip.
At low intensities, no electrons are emitted when �ωL < Ip, but with nowa-
days intense lasers, photoionisation can still occur through different processes.
In all of them the laser intensity has to be relatively high, as single photon
ionisation is not possible any more. The first effect encountered increasing the
laser intensity is multi photon ionisation (MPI) [66]. This is a non-linear pro-
cess where the minimum number of photons from the laser field is absorbed
at once to overcome the Ip. If the intensity is increased even further, more
photons can be absorbed at once and therefore electrons at different energies
will be produced in what is called above threshold ionisation (ATI) [67]. The
ionisation rate (Γ) of these two processes can be written as:
Γn = σnIn (2.35)
The order of the process n refers to the number of photons involved in the
photoionisation process, and σn is the cross section for the absorption of n
photons. In the case of ATI the photoelectrons spectrum is a comb of peaks
spaced by one photon energy, signature of the quantum nature of the energy
transfer [68]. If the intensity is increased even more (I > 1013 Wcm−2), the field
amplitude can become significant compared to the atomic Coulomb potential.
Photoionisation is now possible due to tunnelling [69]. An electron can tunnel
CHAPTER 2. THEORY AND BACKGROUND 51
ionise through the distorted potential and be set free in the continuum. This
is the first step in the process of high harmonics generation (see section 2.3.2).
With the intensity even higher, the distortion of the potential due to the electric
field can be so strong that no potential is seen by the electron that is therefore
free to leave the parent atom, in a process called over the barrier ionisation
(OTBI) [69]. A parameter to predict what will be the dominant mechanism is
the Keldish parameter [70]:
γ =
√Ip2Up
(2.36)
In this equation the ionisation potential, Ip is compared to the pondero-
motive energy, Up, the time averaged energy of the oscillating electron in the
field:
Up =e2E2
4meω2L
(2.37)
Another way to interpret the Keldish parameter is via the tunnelling rate
(ωt), and the frequency of the laser field (ω0). In fact equation (2.36) is equiv-
alent to γ = ω0/ωt.
Ip
MPI ATI TunnelIonisation OTBI
Figure 2.23: Ionisation dynamics. In the perturbative regime γ � 1 the Coulombpotential is not significantly modified by the laser field, and MPI or ATI lead tophoto-ionisation through absorption of multiple photons. When γ � 1 the Coulombpotential is lowered and tunnel ionisation or OTBI can happen.
52 CHAPTER 2. THEORY AND BACKGROUND
When γ � 1 the laser field is not significantly perturbing the Coulomb po-
tential, leaving MPI and ATI as the principal mechanisms of photoionisation.
On the other hand when γ � 1, given the strong perturbation induced by the
electric field, tunnel ionisation and OTBI are the most likely dynamics leading
to photoionisation, as shown in figure 2.23.
A model to predict the instantanous photoionisation rate is provided by
the Ammosov-Delone-Krainov (ADK) theory [71]. According to this model
the instantaneous ionisation rate can be written as:
W (t) = ΩP |Cn∗ |2(4ΩP
ωt
)2n∗−1
e− 4ΩP
3ωt , (2.38)
where the following parameters are defined
Ωp =Ip�
ωt =e |E(t)|√2meIp
n∗ = Z(IH/Ip)1/2
|Cn∗ |2 = 22n∗
n∗Γ(n∗ + l∗ + 1)Γ(n∗ − l∗)
(2.39)
In this expression IH is the hydrogen ionisation potential, while Ip is the ioni-
sation potential of the atom under consideration. Z is the final charged state
of the ion. The effective quantum number l∗ is defined as n∗ − 1 and Γ(x) is
the gamma function (extension of the factorial function). E(t) is the electric
field and me the electron mass. Once the ionisation rate is known, the overall
population of neutrals can be computed as:
N(t) = N0e− ∫ t
−∞ W (τ)dτ , (2.40)
where N0 is the initial population. In this way it is possible to calculate the
instantaneous population of neutrals and free electrons as shown in figure 2.24.
Such information will be relevant both for the broadening of the pulse in the
hollow core fibre, and for the high harmonic phase-matching conditions, as will
be seen in section 2.3.2.
CHAPTER 2. THEORY AND BACKGROUND 53
Fiel
d (V
/nm
)
-100
0
100(a)
Ioni
satio
n ra
te (f
s-1)
0
0.2
0.4
0.6(b)
time (fs)-10 -5 0 5 10
Pop
ulat
ion
(%)
0
50
100(c) free electrons
neutrals
Figure 2.24: ADK calculations in Ne for an intensity I = 1015Wcm−2, λ = 800nm, duration 5 fs. Panel (a) shows the pulse, in (b) is the instantaneous ionisationrate peaked around the field maxima, from which one can compute the neutral andfree electron population in (c).
54 CHAPTER 2. THEORY AND BACKGROUND
2.3.2 High Harmonics Generation
Now I will give an overview of the process underpinning the generation of
attosecond pulses. High harmonics generation happens when, after tunnel
ionisation, the electron manages to recombine with the parent atom in the
presence of an intense oscillating field. After tunnel ionisation the electron is
accelerated in the continuum by the presence of the oscillating electric field,
gaining energy. If the electron is brought back close to the parent atom it can
recombine with it, releasing the energy gained in the continuum in the form
of a photon. The features of this process allow for the production of short
pulses in the spectral range from UV to soft X-ray in a relatively compact
experimental apparatus. For this reason HHG is an attractive method to
develop table-top sources of short and coherent XUV pulses and attosecond
pulses. Experimentally, HHG is usually achieved by focusing an intense laser
pulse onto an atomic or molecular target. As shown in the previous section,
the Keldish parameter should be bigger than one to efficiently tunnel ionise the
target. However, many other aspects of the experiment influence the harmonics
generation including the laser wavelength, the focusing geometry and the pulse
duration. In the following sections the aspects of HHG more relevant to the
present thesis will be discussed.
Three step model
The HHG process can be described by the three-step model [13, 72, 73]. Figure
2.25 depicts these steps. In the first step, the electron tunnel ionises through
the distorted coulomb potential. In the second step, reaching the continuum,
the wave-packet can gain energy from the laser field. For certain ionisation
times, the wave-packet recombines with the parent atom in step three, emitting
the kinetic energy gained in the field plus the ionisation potential as a photon.
The HHG spectrum has very distinctive features. Assuming a linearly
polarised pulse in the NIR, the three step process happens every half cycle of
CHAPTER 2. THEORY AND BACKGROUND 55
TunnelIonisation Acceleration Recombination
(1) (2) (3)
Figure 2.25: Three-step model, The laser field distorts the Coulomb potential in(1) allowing tunnel ionisation to happen. The electron gains kinetic energy in thecontinuum in (2). Upon recombination a photon of energy Ip + KE is emitted in(3).
the electric field. Hence the spectrum shows the interference pattern of a signal
repeated every half cycle, giving rise to the odd harmonics comb separated by
2�ωL. Another notable feature is the overall shape of the spectral emission.
For low order harmonics, where the perturbative regime can be used to
describe the harmonic generation, the conversion efficiency drops rapidly, until
a plateau region is reached, where the conversion efficiency is roughly constant.
At the high energy end of the spectrum we find the cut-off region, where the
harmonics production drops to zero. Figure 2.26 shows the main features of a
HHG spectrum. In the next section I will show how a simple classical model
can reproduce many characteristics of this spectrum
Plateau
Cut-off
Energy
Drop-off
Figure 2.26: Typical HHG spectrum, showing how the conversion efficiency dropsfor low order harmonics, the plateau region, and the cut-off.
56 CHAPTER 2. THEORY AND BACKGROUND
Classical trajectories
The measured HHG spectrum, for a given laser pulse and target, depends on
both the single-atom response and the macroscopic, or phase-matching, re-
sponse. The easiest model for the single-atom response is the classical one,
and despite ignoring the quantum nature of the process, it is able to repro-
duce many features of the experiments. The classical model involves solving
the equation of motion of an electron in an oscillating field. Considering the
case of a linearly polarised field along x, the resulting force on an electron is
F (t) = eE0 cos(ωLt). The equations of acceleration, velocity and position can
be written as:
a(t) =eE0
me
cos(ωLt),
v(t) =eE0
meωL
· [sin (ωLt)− sin (ωLti)] ,
x(t) = − eE0
meω2L
· {[cos (ωLt)− cos (ωLti)] + ωL(t− ti) sin(ωLti)} ,
(2.41)
where ti is the ionisation time when the electron starts moving under the
effect of the electric field only. The initial conditions are set to be v(ti) =
x(ti) = 0. In general, the form of the electric field can be simply integrated to
find the corresponding v(t) and x(t). The extension to the full 3 dimensional
classical description, as required for an arbitrary laser polarisation, is trivial,
each dimension being independent from the others. The interesting parameters
are the boundary conditions. In fact these conditions select the recombining
electrons, which are the ones responsible for the HHG spectrum. Only for some
ti the electron trajectory will come back (re-collide) to the parent atom at a
later time tr. For the simulations I performed with this model the returning
electrons were selected if they crossed the origin within one cycle. However, in
2D this aspect is more complicated, and from a classical point of view a small
region around the core atom has to be defined as the target for recollision. In
figure 2.27 are shown the trajectories computed for a field λL = 800 nm and
different ti.
CHAPTER 2. THEORY AND BACKGROUND 57
time (fs)0 0.5 1 1.5 2 2.5 3
Pos
ition
(nm
)
-15
-10
-5
0
5
10
15
0
1.6
3.2Up
Figure 2.27: Electron trajectories in a oscillating field. The color scale refersto the recombination energy. Black trajectories do not return to the origin. Theprocess repeats every half-cycle but only the first half cycle of trajectories is shownfor clarity. The electric field (red-dashed line) is shown for reference.
As already mentioned, only certain ti allow the electron to recombine
(coloured trajectories), while for others the electron does not return (black
trajectories). The maximum kinetic energy of the returning electrons is 3.2Up.
This corresponds to the cut-off energy of the HHG spectrum. Recalling the
definition of Up given in equation (2.37), to increase the energy cut-off one can
either increase the laser intensity, or increase the driving wavelength. In the
first case the limit is the ionisation saturation intensity, where the target is
almost fully ionised, in the second case the conversion efficiency of the HHG
process decreases with wavelength (scaling as ≈ λ−6.5L ) [74], making it difficult
to measure and use the weak HHG spectra produced with long wavelength
laser fields. This is due to the longer time an electrons spends in the con-
tinuum when driven by a long wavelength field. The longer the electron is
in the continuum the more the wavepacket is spread in space, decreasing the
probability of recombination with the localised parent atom.
58 CHAPTER 2. THEORY AND BACKGROUND
Another feature of the HHG spectrum is that different trajectories have
different excursion times in the continuum. In figure 2.28 the final kinetic en-
ergy of different trajectories is plotted as a function of ti (on the left side of the
plot), and of tr (on the right side of the plot). The trajectories between the two
peaks are defined as “short”, while the ones on the outside are defined “long”.
Moreover, it can be seen that the distribution of ti on the left is narrower than
the distribution of tr on the right. This spread is called “attochirp”, and is the
natural dispersion of the HHG process, with different photon energies being
emitted at different times. This chirp can either be compensated to obtain the
shortest possible attosecond pulse for a given spectrum [20], or can be used as
a natural delay scan to investigate ultrafast dynamics [8]
time (fs)0 0.5 1 1.5 2 2.5 3
Ene
rgy
(Up
units
)
0
0.5
1
1.5
2
2.5
3
3.5 ti tr
Short
Long
0
1.6
3.2Up
Figure 2.28: Long and short trajectories. The left part of the plot represents therecombination energy as a function of ionisation time ti. The right part o the plotshows the same as a function of returning time tr.
CHAPTER 2. THEORY AND BACKGROUND 59
Phase-matching in HHG
In the previous section the single atom response was analysed, and the semi-
classical treatment shown to reproduce the basics features of the HHG spec-
trum. The collective behaviour of the target atoms can now be considered.
The key aspect of HHG generation is coherence, as otherwise much brighter
X-ray sources would be preferable (for example X-ray tubes). For this reason
the coherent emission of all the emitters in the target has to be considered
and the experimental conditions where they constructively interfere has to be
found. The approach is similar to the phase-matching problem of low-order
non-linear optics, with the definition of a phase mismatch parameter Δk, valid
for HHG as well, and the relative coherence length Lcoh = π/Δk over which
constructive interfere happens. In HHG the contributions to the phase mis-
match factor come from different sources. One term is the phase ϕfocus present
due to the focusing of the beam. Another term is provided by the atomic re-
sponse of the atom ϕdip,j, that is related to the phase the electron following a
trajectory j accumulates while in the continuum. Following the notation pro-
vided in [75] the phase mismatch factor for these two factors can be written
as:
Δkωq(r, z) =ωq
c−∣∣∣∣�kdip,j(r, z) + ωq
ωL
(�kfocus(r, z) + �kL)
∣∣∣∣ (2.42)
where �kL is the laser fundamental wave-vector with frequency ωL. The har-
monic order q has frequency ωq. The Gouy phase can be written as:
ϕfocus(z, r) = − tan−1
(2z
b
)+
2kLr2z
b2 + 4z2(2.43)
From equation (2.43) it can be seen that, on axis (r = 0) the wave-vector
�kfocus points always in the same direction, since tan−1 is a monotonic function
and �kGouy = ∇ϕfocus. The other phase factor is ϕdip,j(r, z). In this case j
labels a specific trajectory. In general it can be written as the classical action
on a trajectory j with ionisation time ti and return time tr:
60 CHAPTER 2. THEORY AND BACKGROUND
ϕ(ti, tr) = −∫ tr
ti
S(t′′)dt′′ (2.44)
The integrand of equation (2.44) is defined as S(t′′) = Ekin(t′′) − Epot(t
′′).
In the long pulse approximation (the envelope shape is assumed not relevant
to the intra-cycle dynamics), the energy is proportional to the ponderomotive
energy Up, and therefore to the laser intensity, since Up ∝ I/ω2L. For this
reason equation (2.44) can be rewritten as:
ϕdip,j = −αjUp/ωL (2.45)
As shown in [76], the number of trajectories that has to be taken into
account can be limited to two paths, the long and short trajectories.
Neglecting dispersion effects (kq = qkL = qωL/c), the expression for the
on-axis phase mismatch factor can be written as:
Δkωq = αjdUp/ωL
dz+ωq
ωL
2
b(1 + 2z2/b2)(2.46)
The factor representing focusing is always positive, while the dipole factor,
being proportional to the laser intensity, is positive before the focus (dI/dz >
0) and negative after the focus (dI/dz < 0), giving the well-known result of
phase-matching of HHG after the focus. Figure 2.29 is a representation of
different phase-matching conditions, for different trajectories, short in the left
column, and long in the right column, and for different harmonics, 21st, 35th
and 45th from top to bottom. The color scale represents the coherent length
Lcoh. Note how phase-matching conditions are obtained in different positions
for long and short trajectories. The resulting divergence of these trajectories
is different as well, as shown by the different direction of the generated wave
indicated with the red arrows.
So far dispersion has not been included, together with the more dynamic
aspects for phase-matching. The reason is that such effects are not adiabatic,
CHAPTER 2. THEORY AND BACKGROUND 61
i.e. they cannot be considered constant during the HHG process, as was for
the Gouy and the dipole phase [75]. However, if considered for small spatial
intervals the local refractive index can be expressed as a function of other
parameters like density and wavelength, and terms including the neutral and
electron dispersion can be added to the phase-matching equation (2.42), for
example computing the instantaneous free electron population with the ADK
model.
By now the complexity of phase-matching should be clear, it involves both
the understanding of the microscopic aspects of HHG, and of the macroscopic
aspects. This sensitivity can be sometimes an obstacle in the path of scaling
high harmonics yield and energies, but it can be used to tailor the attosecond
emission, for example selecting or gating an isolated attosecond pulse (see
3.3), or as a diagnostic tool as well, for example retrieving the dipole phase of
a target of interest as it has been done in [78].
62 CHAPTER 2. THEORY AND BACKGROUND
Figure 2.29: HHG phase-matching. Efficient generation (white parts of the col-ormap), are achieved at different positions for short (left) and long (right) trajecto-ries. From top to bottom harmonic 21, 35 and 45 are considered. The red arrowspoint in the direction of the harmonic wave-vector, showing how the divergence ofthe radiation is different for the two paths. Image adapted from [77].
63
Chapter 3
Ultrafast light sources
development
In this chapter I will present the main results obtained during my PhD. Some
more background details will be provided, focusing on the aspects more rel-
evant to the experiments performed. In general the experiments performed
aimed at developing new light sources, or improving the performance of some
others already well established, to allow new attosecond experiments.
3.1 Laser System
In the following sections the features of the laser system in the Attosecond
Laboratory at Imperial College will be described [79]. The commercial CPA
system is based on Ti:Sapphire oscillator and amplifier (Femtopower HE CEP,
Femtolasers GmbH). The output is 2.5 mJ, 28 fs at 1 kHz repetition rate.
The pulses are spectrally broadened in a hollow core fibre to achieve, after
compression with chirped mirrors, a pulse duration as short as 3.5 fs and up
to 1 mJ pulse energy, while maintaining CEP stability.
64 CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT
3.1.1 Oscillator
The Ti:Sapphire oscillator (Femtosource, Femtolasers GmbH) is shown in fig-
ure 3.1. The pump laser (Verdi, Coherent) is a 532 nm, 4.4 W frequency
doubled Nd:YVO4 CW laser. Soft Kerr-lens mode-locking, initiated by mov-
ing one of the intracavity mirrors (S) mounted on translation stage, produces
a pulse train at 78 MHz with a duration of 10 fs and 400 mW average power
(5 nJ/pulse). Intracavity dispersion compensation is provided by two chirped
mirrors (CM), further dispersion control is given by a pair of wedges (W). An
acousto-optic modulator (AOM) is installed in the pump beam to allow fast
modulations of the pump power for CEP control purposes.
A 50% beam splitter (BS) delivers half of the oscillator energy to an f−2f
for the measurement of the CEP, and the remaining half is delivered to the
multi-stage amplifier through a Faraday isolator (F).
Pump Laser: 4.4W 532nm
to f-to-2f
PD
Ti:S
W
to streatcher andamplifier
BS CMCM
Figure 3.1: Oscillator layout. A Ti:S crystal is pumped at 532 nm by 4.4 W of afrequency doubled Nd:YVO4. Two chirped mirrors (CM) provide intra-cavity neg-ative dispersion. Intra-cavity wedges (W) and an acousto-optic modulator (AOM)in the pump beam allow manipulation of the CEP and intra-cavity dispersion. Theoscillator output is delivered to the amplifier through a Faraday isolator (F). theoscillator output is monitored by a photodiode (PD).
The CEP of the oscillator is measured in the so called “fast loop” interfer-
ometer (XPS800, Menlo Systems) shown in figure 3.2. A photonic crystal fibre
(PCF) is used to obtain an octave spanning spectrum from the oscillator sig-
nal. A dichroic beam splitter (DBS) separates the green components (around
532 nm) from the red components (around 1064 nm). The red components are
CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT 65
focused onto a periodically poled potassium niobate crystal (KNbO3, PPL)
for efficient SHG. The two arms of the interferometer are recombined with a
polarising beam splitter. The signal obtained is sent to a grating, dispersed
and the beat note f0 is recorded on an avalanche photodiode. The transmitted
part of the green arm of the interferometer is sent to a second avalanche pho-
todiode for the measurement of the repetition rate frep. These two signals are
fed into fast analogue electronics to provide a correction signal to the AOM
in the oscillator pump beam. This interferometer stabilises the pulse to pulse
fluctuations of the CEP by locking the f − 2f beat note at frep/4. In this way
the waveform of the pulse is the same every four pulses. The signal manip-
ulation is done with fast analogue electronics so that the feedback loop can
act on a single shot basis. The actuator of the feedback loop is implemented
with the acoustic optic modulator on the pump beam, so that a difference in
pump power can correct the CEP. When a coarser manipulation of the CEP
is necessary, the thin wedges pair can be translated to provide further control
of the intra cavity dispersion and CEP.
fromoscillatorPCF
DBS
PPL
PID AOM
Figure 3.2: CEP fast loop. The oscillator pulse is spectrally broadened in a PCFbefore a dichroic mirror (DBS) selects different wavelengths components sending thelong one (red) to a doubling crystal. Recombination of the two arms happens at apolarised beam splitter and the beat note is measured in parallel to the repetitionrate.
66 CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT
3.1.2 Amplifier
The amplifier consists of a Ti:Sapphire crystal pumped by a 12 mJ, 527 nm
(frequency doubled Nd:YLF) Q-switched laser pulse (DM30, Photonics Indus-
tries). The crystal is cryo-cooled to 170 K in a vacuum chamber at ≈10−2
mbar. The oscillator pulse is stretched to a pulse duration of ≈20 ps with a
double pass through 4 rods (5 cm each) of SF57 glass. The stretched pulse
goes through the Ti:S crystal 10 times. After pass four the repetition rate is
reduced from 80 MHz to 1 kHz through a Pockel cell unit. The pulse is then
shaped with a Dazzler [39] (Dazzler, Fastlite) to compensate for dispersion and
gain narrowing. After pass eight a telescope recollimates the beam to reduce
the intensity in the crystal. After the tenth pass the beam goes through a
transmission grating compressor, delivering an output of 2.5 mJ, 28 fs, at 1
kHz repetition rate. Figure 3.3, shows the amplifier layout.
PC
PD
PBS1
PBS2
Ti:S
From pump laser
stretcherglass
Dazzler
Telescope
2.5mJ, 28fs, 1kHz transmission grating compressor
fromoscillator
Figure 3.3: Amplifier layout. The oscillator output is stretched in a glass stretcherbefore performing 10 passes through the amplifier crystal. Compression is achievedin a transmission grating compressor. See text for details.
While the fast-loop locking system stabilises the oscillator CEP on a shot
to shot basis, a second feedback loop is necessary to stabilise CEP fluctuations
on a longer time scale that are caused by effects beyond the oscillator stability.
For example, vibration of the compressor, energy fluctuations in the pump
CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT 67
power of the amplifier or thermal drifts of the optical system can change the
CEP value of the output pulse. For this reason a CEP monitor and feedback
loop are used on a portion of the CPA output beam. While the low pulse
energies of the oscillator require a photonic crystal fibre to obtain an octave
spanning spectrum, the output of the amplifier is strong enough to produce
octave spanning white light in a sapphire plate. Figure 3.4 shows how the slow
locking loop measures the CEP.
sapphireplate
BBOcrystal
Spectrometer
polariser
SHGWLG
PIDAOM FFT
from fast loop
Figure 3.4: Slow locking CEP loop. The power available after the amplifier allowsto produce an octave spanning spectrum by focusing the beam in a sapphire plate.The feedback loop runs through a computer at 20-30Hz .
The fringe pattern obtained interfering the short wavelengths and the
frequency-doubled long wavelength components of the white light generated
in the sapphire plate, provides direct access to Δϕ0, that can be measured on
a computer at a repetition rate of 20-30 Hz. Given that the fast fluctuations
of the CEP are already stabilised by the fast loop, this bandwidth is enough
to compensate for the slower drifts of the system. The measured drifts are
converted to a voltage signal acting on the AOM in the pump beam of the
oscillator, together with the fast loop corrections.
68 CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT
3.2 Hollow core fibre pulse compression
As introduced in chapter 2, the main way to obtain attosecond pulses is HHG.
In our laboratory, focused on developing techniques for attosecond pump-probe
studies [3], we adopted amplitude gating to produce isolated attosecond pulses
[58]. More about gating and shaping techniques of attosecond radiation will be
discussed in section 3.3. In this section the production of the few cycle pulse
used to implement amplitude gating will be presented.
To obtain a few cycle pulse starting from the CPA laser output, spectral
broadening was achieved through SPM (see figure 2.8) in a hollow core fibre,
and pulse compression through chirped mirrors (see figure 2.5). This technique
is well established [80] with the capability of delivering up to a 1TW of peak
power in a 5 fs, 5 mJ pulse [81] or providing sub-4 fs pulses at slightly lower
energies [82–84], and it has been possible to reach even the single-cycle duration
[16]. The most challenging aspect in developing this technique is the energy
scaling, in order to use efficiently the more energetic CPA laser pulses available
while maintaining good performances at higher pulse energies. The trade off
between power and performance is not trivial and has been investigated in our
laboratory [32].
The first experiments exploiting SPM for spectral broadening of a pulse
were performed in bulk material [85], but it was soon realised that high inten-
sities could not be handled this way, due to the intensity induced damage to
the material, and also the non spatially uniform SPM induced in free propa-
gation. From here the idea of guided propagation in gases [80] was explored.
Solving Maxwell equations for a hollow wave-guide with inner radius a � λ
and infinite thickness (i.e. the outer interface does not contribute to the field)
shows [86] that the modes with the lowest propagation constant1 α for glass
waveguides (n < 2.02) are the hybrid EH1m modes, as shown in figure 3.6.
Such modes are essentially transverse modes (negligible z component of the
1P (z) = P (0) exp(−αz)
CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT 69
fields if 2πa/λ � 1) and polarised. The radial intensity profile within the
hollow core is given by:
I1m = I0 · J02(u1mr/a) (3.1)
In (3.1) J0 is the zero order Bessel function of the first kind, u1m is the mth
zero of J0, and a is the fibre radius. Figure 3.5 shows the first four modes,
with the hollow core represented by the black dashed line.
EH11 EH12
EH13 EH14
Figure 3.5: First four EH1m modes that can be excited by a linearly polarised fieldin a hollow core fibre. The black-dashed line is the fibre entrance, the red continuousline the radial intensity profile of the mode. Note that the excited mode is zero inthe cladding of the fibre (outside the black-dashed line), while here the field hasbeen plotted at all radii for reference.
To efficiently excite the EH11 mode the laser spot-size has to be chosen
appropriately. The goal is to achieve the maximum overlap between the Gaus-
sian profile of the incoming beam Eg, and the mode to excite E1m. Using the
normalised fields and assuming a linearly polarised pulse one can obtain [87]:
70 CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT
Eg =
√2
πw20
exp (−r2/w20) (3.2a)
E1m =J0(u1mr/a)√∫ a
02πrJ2
0 (u1mr/a)dr(3.2b)
∣∣∣∣∫ a
0
Eg · E1m2πrdr
∣∣∣∣2 ==4[∫ a
0rJ0(u1mr/a) exp (−r2/w2
0)dr]2
w20
∫ a
0rJ2
0 (u1mr/a)dr
(3.2c)
From equations (3.2) it is possible to see that there is an optimum w0/a
such that the coupling of the EH11 mode is optimised. Figure 3.6 shows that
this optimum is w0/a = 0.64, where the coupling efficiency is 98%.
L (m)0 0.2 0.4 0.6 0.8 1
Mod
e at
tenu
atio
n (%
)
0
10
20
30
40
50
60
70
80
90
100
EH11
EH12
EH13
EH14
w0/a0 1 2 3
Cou
plin
g ef
ficie
ncy
(%)
0
10
20
30
40
50
60
70
80
90
100
110
98% at w0=0.64a
Figure 3.6: Fibre parameters to consider when optimising the fibre throughput.On the left is the natural attenuation of modes in the fibres, showing that themode EH11 is the one experiencing least attenuation. On the right is the couplingefficiency, i.e. the overlap between each mode and a Gaussian profile at the focus,as a function of w0/a. The optimum coupling is obtained for the mode EH11 atw0/a = 0.64 with a coupling of 98%
When trying to scale the energy throughput of a fibre to higher levels other
parameters need to be considered. In fact non-linear effects can start to play
an increasingly important role, for example self-focusing and plasma-induced
CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT 71
defocusing can alter significantly the focal spot size at the fibre entrance, de-
teriorating the coupling efficiency and even damaging the fibre entrance. The
input peak power P0 has to be lower than then critical power for self-focusing
Pcrit since self focusing would prevent an efficient coupling into the fibre. This
can be expressed [88] in terms of the pressure of the gas p as:
Pcrit =λ202k2p
, (3.3)
where k2 = n2/p with n2 the non linear refractive index responsible for the Kerr
effect as in (2.25). For example for 1 bar of Ne the critical power at 800 nm
is 0.5 TW (1012 W) [87], power levels that can be reached by multi-millijoule
femtosecond systems. Different strategies have been proposed to replace the
initial static filled fibre approach and overcome such limitation. Differential
pumping of the fibre allows one to evacuate the fibre entrance to few mbar or
less, limiting the gas density and therefore the non-linear effects in the coupling
step [32, 81, 83, 89, 90]. Circularly polarised light can be used due to the lower
Kerr-effects (χ(3)) and the lower ionisation rate it induces [91–93]. Pre-chirped
pulses have been used to lower the non-linearity at the fibre entrance as well
[81, 83].
Let us consider the case where a fixed spectral broadening is required, for
example to compress a 28 fs pulse from a CPA system, down to the few cycle
regime. Defining Δω as the final spectral bandwidth, and the initial bandwidth
Δω0, the broadening factor F = Δω/Δω0 can be shown to be [94]:
F =
√1 +
4
3√3ψ2m (3.4)
The variable ψm is the the phase shift accumulated in the fibre and can be
expressed as
ψm =n2ω0P0Leff
cAeff
= γP0Leff (3.5)
72 CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT
In this case P0 is the input peak power, Aeff is the effective area of the
fibre mode (≈ 0.48πa2 [94]) and n2 = k2p is the non-linear refractive index of
the medium. The effective length Leff depends on the experimental conditions
implemented [32, 94]. For a linearly polarised (LP) pulse and static fill (SF) of
the fibre the Leff is expressed as [94]:
LSFLPeff =
∫ L
0
e−αzdz =1− e−αL
α(3.6)
with L being the actual fibre length and α the attenuation constant of the
mode.
For a circularly polarised pulse (CP) the only modification required is re-
lated to the non-linear refractive index in (3.5) and since nCP2 = 2
3nLP2 [95] one
can write:
LSFCPeff =
2
3LSFLPeff =
2
3
(1− e−αL
α
)(3.7)
For a differentially pumped (DP) fibre the pressure is varying along the
fibre length [89]:
p(z) = p(L)
√z
L(3.8)
Including this dependence in equation (3.5) gives another expression for the
effective length [32]:
LDPLPeff =
1√L
∫ L
0
√ze−αzdz ≈ 2
3
(1− e−1.21αL
1.21α
)(3.9)
In the experimental campaign that will be presented in the next section,
these different experimental conditions have been tested and the corresponding
effective lengths are shown in equations (3.10).
CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT 73
LSFLP =1− e−αL
α= 0.94 m (3.10a)
LDPLP ≈2
3
(1− e−1.21αL
1.21α
)= 0.62 m (3.10b)
LSFCP =2
3
(1− e−αL
α
)= 0.63 m (3.10c)
Focusing on the static fill case and linearly polarised pulse, after choosing
the required broadening with the parameter F , one needs to determine the fibre
radius. Numerical simulations [94] showed that requiring the plasma effects
to be small compared to the Kerr effects sets a minimum radius available
for a given pulse duration and energy. The panel (a) of figure 3.7 shows the
minimum radius to be used with different gases in order to prevent detrimental
plasma effects.
Once the fibre radius is chosen, the required gas pressure pF for a given
spectral broadening F can be expressed as in equation (3.11) and it is shown in
panel (b) of figure 3.7 in the case of He gas target (k2 = 2.9 ·10−25m2W−1bar−1
[94]).
pF =cAeff
2k2ω0P0Leff
[3√3(F 2 − 1)
]1/2(3.11)
In order to scale the power to higher levels for a fixed broadening factor in
the SFLP case, one can select the minimum radius amin at each input energy,
and compute the minimum pressure required with that radius, and with it the
critical power limit. The result is that the input power cannot be increased at
will. At some point the peak power P0 will be comparable to Pcrit. The panel
(c) of figure 3.7 shows that this condition happens at about 4 mJ pulse energy
level (28 fs input pulse duration, He gas medium) preventing a straightforward
energy scaling of a hollow core fibre pulse compressor setup beyond this level.
74 CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT
0 1 2 3 4 5
a min
(m
)
0
200
400
600(a)
HeNeArKr
0 1 2 3 4 5
p min
(bar
)
0
1
2
3
4
5(b)
SFLPDPLPSFCP
Energy (mJ)0 1 2 3 4 5
Pow
er (T
W)
0
0.05
0.1
0.15
0.2(c)
P0Pcrit
Figure 3.7: The minimum radius of a SF fibre is shown as a function of pulseenergy for a 28 fs (FWHM) pulse and for different gases in (a). Below such values theplasma effects are comparable to the Kerr effects, degrading the fibre performance.The pressure required to achieve a broadening factor for a given fibre diameter isshown as a function of pulse energy in (b). The intersection between the input powerP0 (black) and the critical power at the minimum radius, shows that straightforwardpower scaling of hollow core fibres is prevented by self focusing in (c).
CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT 75
3.2.1 Experimental setup
An experimental campaign [32] was performed to to investigate the fibre per-
formance under the different experimental condition mentioned in the previous
paragraph. We wanted to test whether differentially pumping the fibre is a vi-
able method to achieve few cycle pulses while maintaining good CEP stability.
Figure 3.8 shows the hollow core fibre set-up in our laboratory.
pump
pum
p
gas
2.5 mJ, 1 kHz, 28 fs
f-2f interferometer
poin
ting
stab
ility
Figure 3.8: Fibre setup. The CPA output is focused with a 1.5m mirror. Thebeam pointing is stabilised with a feedback loop. The entrance and output of thefibre can be pumped independently. Pulse compression is achieved with 10 bounceson multilayer chirped mirrors. The CEP of the fibre output is monitored with a f-2finterferometer.
The output of the CPA is focused with a f = 1.5 m focal length mirror into
the fibre entrance. The fibre has an inner diameter of 260 μm and is one meter
long. For this inner diameter the optimal focal spot size is 169 μm. Figure 3.9
shows the measured spot size, resulting in 162×185 μm. The astigmatism has
to be attributed to the CPA output quality, as no spatial filter is implemented
in the system.
The laser pointing is stabilised by recording the focal spot position on a
CCD camera and adjusting the pointing with a motorised mirror controlled in
a feedback loop. The fibre entrance and exit chambers can be pumped indepen-
dently to perform measurements both with the fibre statically filled or differ-
76 CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT
x ( m)-150 -100 -50 0 50 100 150
y (
m)
-150
-100
-50
0
50
100
150
Figure 3.9: Focal spot size at the fibre entrance. The optimum value is 170 μm
entially pumped. To switch between circular and linear polarisations regimes
a quarter wave plate was positioned before the fibre entrance to make the in-
put beam circularly polarised, while a broadband achromatic wave plate2 was
positioned at the fibre output, before the chirped mirrors, to bring the pulse
polarisation back to linear. To avoid non-linear effects the entrance window is
positioned 85 cm from the fibre entrance, similarly the output window is 45 cm
from the fibre end. The beam is then re-collimated with a f = 87.5 cm mirror.
The pulse is compressed with 10 reflections on double angled chirped mirrors
(UltraFast Innovations GmbH) providing -36 fs2 dispersion per bounce in the
spectral range 500-1000 nm. Figure 3.10 shows the typical spectral properties
of the input and output pulses of the fibre.
The CEP stability of the fibre output was measured with an f-2f interfer-
ometer, similar to the one illustrated in figure 3.4. The main difference is that
now, an octave spanning spectrum is already available, so no WLG generation
is required, and the fibre spectrum is directly focused in the frequency dou-
bling crystal. The delay between the two frequency components is provided
by 1 mm of glass dispersion. The fringe pattern is then recorded as a function
of time and the phase difference between long and short wavelengths can be
2λ = 0.25± 0.007 in the 600-950nm range
CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT 77
lambda (nm)500 600 700 800 900 1000
Inte
nsity
(arb
. u.)
0
0.2
0.4
0.6
0.8
1 InputOutput
time (fs)-50 0 50
Inte
nsity
(arb
. u.)
0
0.2
0.4
0.6
0.8
1InputOutput
Figure 3.10: Input spectrum (left) and FTL temporal profile (right) at the fibreinput (black line) and at the fibre output (red dotted line).
extracted and stabilised with a feedback loop on the AOM in oscillator pump
laser. Figure 3.11, shows the typical CEP-stability performance of the fibre
output. The CEP values distribution can be fitted with Gaussian profile with
σmean = σ/√Nshots, where σ is the statistical error on each shot measurement.
(a)
0 1 2 3 4
lam
bda
(nm
)
480
490
500
510
520
530
540
lam
bda
(nm
)
480
490
500
510
520
530
540
(b)
time (hours)0 1 2 3 4
CE
P (m
rad)
-1000
0
1000 (c)
CE
P (m
rad)
-1000
0
1000
=194 mrad
(d)
Figure 3.11: Fibre output CEP stability. The interference pattern between longand short wavelengths of the beam are measured as a function of time in (a). theintegrated signal in (b) shows that the coherence is preserved over time. The CEPcan be extracted for each spectrum measured and is shown as a function of time in(c). The resulting distribution has a gaussian profile with σ = 194 mrad as shownin (d).
78 CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT
3.2.2 Results and discussion
The main results from this experimental campaign are a set of measurements
at different input energies, for different fibre operation modes to explore the
energy scaling of hollow fibre pulse compression. In all measurements the
pressure of the fibre was adjusted to achieve a 4 fs FTL spectrum.
The first results presented in figure 3.12 are the output energies achieved
under the different experimental conditions, as a function of input energy.
vacuum
SFLPSFCPDPLPtheory
68%
Figure 3.12: Fibre output energy as a function of input energy, showing the clamp-ing of the transmission at higher energies. Adapted from [32].
Below 0.6 mJ input energy all modes of operation yield results close to the
vacuum transmission of 67%. At higher energies even the vacuum transmission
is not maintained, most probably due to the onset of non-linear effects even at
a pressure level of 10−2 mbar. The interesting aspect is the difference between
the SFLP case with respect to the SFCP and DPLP cases. It can be seen how
for SFLP, increasing the power input above 1.5 mJ does not affect the power
output that remains around 0.6 mJ. On the other hand, for DPLP and SFCP
the power output can be increased up to 0.8 mJ.
The theoretical predictions come from propagation simulations performed
by D. Austin (Imperial College), with a coupled-mode, split-step code which
includes the dispersion and losses of each mode, Kerr effects (self-steepening
included) and ionisation. The ionisation rate was calculated using the ADK
model as introduced in equation (2.38). The simulations were performed for
CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT 79
the DPLP case, with a gaussian spatial profile (1/e2 = 166μm) and 28 fs pulse
duration. The required pressure was set according to equation (3.11), in order
to achieve a 4 fs FTL spectrum. Figure 3.13 shows the theoretical pressure
required and the experimental data points.
SFLPSFCPDPLP
Figure 3.13: Fibre gas pressure required for different experimental condition andenergies. The points are the experimental values, lines are the expected pressureaccording to equation (3.11). Adapted from [32].
From these simulations it is possible to clarify the origin of the losses at
higher energies. We compared simulations where the direct ionisation losses
were taken into account (i.e. the energy required to ionise the gas atoms in
the fibre was subtracted from the system), to ones where ionisation was not
accounted in the energy balance. The results show that direct ionisation losses
are negligible and therefore suggest ionisation defocusing and related coupling
into higher order modes as main mechanism of energy loss.
The next results presented are related to the CEP stability in a hollow
fibre system. The propagation through any dispersive medium shifts the CEP
due to the difference between the group and phase velocity vg and vp. Over a
distance L, such shift can be expressed therefore as:
Δϕ = ωL
(1
vp− 1
vg
)≈ 2πL
dn
dλ=ω2L
c
dn
dω(3.12)
One source of CEP fluctuations arises from SPM. In fact an intensity fluc-
tuation δI0 induces a change in the refractive index and therefore a phase shift
80 CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT
δϕSPM[96]:
δϕSPM =ω20
c
∂n2
∂ω
∣∣∣∣ω0
LδI0 (3.13)
Another instability source is related to free electron dispersion experienced
by the pulse in the plasma produced by ionisation. The plasma refractive index
in fact depends on the pulse intensity and gas pressure via the free electron
density ρe:
nplasma =
√(1− ω2
p
ω2
)≈ 1− ω2
p
2ω2, ωp =
√e2ρe/ε0me (3.14)
where ωp is the plasma frequency. From this expression one can derive the
plasma induced CEP shift due to an intensity fluctuation as
δϕplasma ≈ e2L
meε0ω0c
∂ρe(I0, p)
∂I0δI0 (3.15)
To simulate the CEP stability, different intensities were set as input param-
eters (1% intensity fluctuations) and the distribution of the CEP output was
computed and σCEP extracted. Figure 3.14 shows the results of the simulations
(solid line) and the experimental data for SFLP and DPLP.
SFLPDPLPtheory
Figure 3.14: Fibre CEP rms for different pulse energies and experimental config-urations. Adapted from [32].
CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT 81
It can be seen how the CEP stability degrades while increasing the pulse
energy from 0.5 to 1.25 mJ. The simulations confirmed this degradation is
driven by ionisation-induced instabilities (δϕplasma) as switching SPM off in
the simulations does not change the CEP performance significantly. Above
1.25 mJ, σCEP does not increase any further. The mechanism responsible for
this stabilisation is identified as energy loss. As shown in figure 3.12, above
1.25 mJ more and more energy is coupled into higher order modes, preventing
a higher intensity to be reached and therefore limiting the related instabilities.
The performance of the SFLP and DPLP is very similar, proving of the validity
of differentially pumping schemes with respect the static filled ones.
3.3 HHG for isolated VUV and XUV pulses
production
In this section I will present results related to the spectral characterisation and
manipulation of the VUV and XUV attosecond pulses. These measurements
represent the first step in order to fully characterise the attosecond pulses, as
will be shown in chapter 5, and were used to identify optimal experimental
parameters, such as CEP, gas pressure and target position, for the streaking
measurements.
3.3.1 Gating the HHG emission
As explained in [75], to obtain attosecond pulses from the HHG process, phase-
matching is crucial. Moreover, obtaining an isolated attosecond pulse, rather
than an attosecond pulse train, requires a careful experimental design. The
standard generation of isolated attosecond pulses requires temporally gating
the high harmonics emission produced with an intense femtosecond NIR laser
to a single burst. When no gating technique is applied, the harmonics emis-
sion happens every half cycle of the driving NIR laser, resulting in a train of
82 CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT
attosecond pulses, not ideal for pump-probe experiments.
The more straightforward technique is amplitude gating [58]. It consists in
limiting the pulse duration of the driving NIR field to the few cycle regime.
In this way, with the correct choice of CEP, the highest energy portion of the
harmonics spectrum will be emitted only once, corresponding to the peak of
the electric field waveform. It is then possible to select this emission with a
spectral filter covering the appropriate energy range.
In order to achieve isolated attosecond pulses not only in the cutcut-off
energy range, and with longer driving fields, other gating techniques have been
developed. In polarisation gating [97, 98] the HHG dependence on polarisation
[99] is exploited. With circularly polarised light, no electron trajectories are
allowed to return to the proximity of the parent ion, therefore frustrating the
harmonics emission. The driving electric field can therefore be shaped so that
the polarisation changes within the pulse duration, going from circular, to
linear and then back circular again (different sign). It is possible to limit the
linear state to only one half cycle, obtaining a single burst of harmonics at all
energies.
In double optical gating (DOG) [100], the polarisation gating technique has
been further developed to be used with even longer pulses.
In fact depletion of the ground state before reaching the linearly polarised
part of the pulse can be detrimental when trying to implement polarisation
gating with long (> 6 fs) pulses. The problem with using longer pulses for
the production of isolated attosecond pulses is that, not only the emission has
to be frustrated for longer, but in this interval of time the population of the
ground state of the target atom must not be depleted.
In DOG a 2ω0 component is added to the driving field, breaking the sym-
metry of the driving field so that the harmonic emission occurs every cycle
rather than every half cycle. In this way pulses up to 9 fs can be used to
obtain isolated attosecond pulses [100].
In order to use directly the longer output of standard CPA laser systems
CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT 83
(≈20-30 fs) one can implement generalised double optical gating [30] (GDOG),
where DOG is optimised by using elliptically polarised pulses rather than the
circular ones. With GDOG the intensity of the leading edge of the pulse is
lowered significantly with respect to DOG, allowing the generation of isolated
attosecond pulses with driving fields as long as 28 fs [30].
The ionisation technique exploits the effects of depletion of the ground state
during HHG [101]. By applying a few cycle pulse with an intensity greater than
the ionisation saturation intensity it is possible, for certain CEP values, to con-
fine the attosecond pulse emission to a single burst. The CEP in a few cycle
pulse in fact allows a smooth and precise way to modify the instantaneous
intensity delivered on target. Experimentally this implementation is rather el-
egant since the optimum CEP value can be chosen by looking at the generated
harmonics, where a clear transition between separated harmonics and a con-
tinuum spectrum can be seen, both in the cut-off and in the plateau region of
the generating harmonics, confirming the transition from multiple to isolated
attosecond pulse generation [101].
The latest addition to the gating techniques for isolated attosecond pulses is
the so-called lighthouse effect [102, 103]. Here, rather than spectrally selecting
the cut-off part of the HHG spectrum as in amplitude gating, or in frustrating
the harmonics emission either via polarisation (DOG-GODG) or depletion of
the ground state(ionisation gating), the gating exploits the spatial properties
of the pulse. If an appropriate wavefront rotation is imprinted on the driving
field, different half cycles will be instantaneously propagating in different di-
rections. Wavefront rotation can be achieved by misaligning a pair of wedges,
and therefore imprinting an angular chirp on the pulse (angular dispersion).
When such a pulse is focused, mapping angles to positions, the pulse will be
spatially chirped, i.e. with a rotating wavefront. In this way, the harmonics
emission will be into slightly different directions at each half cycle and can be
spatially isolated after some propagation [104].
In our laboratory, amplitude gating is implemented with the few cycle pulse
84 CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT
described in 3.2 for the production of isolated attosecond pulses [79].
In the following sections I will present the experimental apparatus for the
HHG process and the spectral characterisation of HHG radiation, and the
results obtained in the process of optimising the XUV and VUV pulse produc-
tion.
3.3.2 Experimental setup
The Attosecond beamline at Imperial College consists of a series of vacuum
chambers accommodating different experimental set-ups as seen in figure 3.15.
1 m
focusing mirror
gas jets Al filterflat fieldgrating
imaging MCP CCDcamera
two partmirror
gas targetfilters
irisirisCCD
camera
Figure 3.15: Beamline layout. The first chamber accommodates the gas jets forHHG. The second chamber contains an Al filter for the calibration of the flat fieldspectrometer in the third chamber. In the last chamber is positioned the electrontime-of-flight spectrometer, the metallic filters for spectral selection of the harmonicsradiation and the two part mirror assembly.
The first chamber is dedicated to the HHG process. The NIR pulse enters
the chamber through a 1-mm thick fused silica window and is then focused
with an f = 75 cm mirror. Within the Rayleigh range (15 mm) are positioned
the gas targets. For the production of synchronous VUV and XUV pulses
I used an in-line solution [105], positioning first the gas target for the VUV
production (Kr), and then the gas target for the XUV production (Ne). These
targets, operating at 1 kHz, are piezo actuated for the release in the vacuum
CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT 85
system of gas plumes (≈ 1017cm−3), as shown in figure 3.16. The focal spot
position was determined from the onset of plasma formation in air (chamber
partially evacuated at ≈ 10−1 mbar). This allowed positioning of the gas jets in
approximately the correct position in the propagation direction (z), as shown
in figure 3.16 where the plasma formation can be seen between the two gas
jets.
gas inlet
piezo disk
1.5 mm
HV
laserbeam
Figure 3.16: Gas jet schematics (left) and experimental implementation of a in-linepair (right) where the plasma formation is visible as a bright spot between the twojets.
The gas jet valve opening is triggered with the laser pulses. The two gas
targets were mounted on fully motorised x-y-z stages for alignment and opti-
misation purposes.
The second chamber serves as a differential pumping stage, and contains
an Al filter for the spectral calibration of the UV radiation. This chamber
houses the double slit used for the ablation plume harmonics spatial coherence
experiment [33] (see section 3.4).
The flat field spectrometer consists of a variable groove density, “flat field”,
gold coated grating (1200 l/mm, 001-0437, Hitachi) [106]. This grating is de-
signed to disperse the harmonics on a flat plane, where a micro channel plate
(MCP) is positioned to record the spectral intensity. The imaging MCP is
mounted on a moving flange so that different photon energies (16-200) eV can
be measured. The imaging MCP has two stacked plates with an active area
of 40 mm diameter. A phosphor screen (P46) allows detecting the UV photo-
electrons with a CCD camera (14 bit Coolview FDI, Photonic Science) in the
86 CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT
visible spectral range (530 nm).
The spectral calibration of the flat field spectrometer was performed with
an Al filter. The Ne harmonics in fact go beyond the Al absorption L-edge at 72
eV. Therefore the measurement of Al filtered harmonics allows the calibration
(pixel/wavelength) of the spectrometer by using the known grating dispersion
equation and the Al absorption edge position, as shown in figure 3.17
Photon energy (eV)40 45 50 55 60 65 70 75 80 85
Inte
nsity
(arb
. u.)
0
0.2
0.4
0.6
0.8
1Input spectrumfiltered spectrumAl transmission
Figure 3.17: Full spectrum (solid blue) and Al-filtered spectrum (dashed-red) of Neharmonics. The position of the Al L-absorption edge (dotted black line in overlay)allows the calibration of the flat-field spectrometer.
3.3.3 Spectral results
In figure 3.18, two typical VUV and XUV spectra can be seen. These spectra
were measured as a function of several parameters to find the best compromise
for the production of the two pulses simultaneously. For future reference, when
only the spectral information is reported, a spatial integration was performed
over a small window around the harmonics signal.
The choice of Ne gas for the production of the XUV pulse is a standard
one. It provides a high ionisation potential (IpNe = 21.6 eV) that allows a
higher harmonics cut-off with respect to noble gases with a lower Ip such as Ar
or Kr. On the other hand I did not use He, with an even higher Ip, because I
wanted to implement a loose focusing geometry to optimise the phase-matching
CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT 87
Kr
Energy (eV)16 18 20 22 24 26 28
Div
erge
nce
(mra
d)
-10
-5
0
5
10
Ne
Energy (eV)40 60 80 100
Div
erge
nce
(mra
d)
-10
-5
0
5
10
Figure 3.18: XUV (right) and VUV (left) spatially resolved spectra.
conditions and conversion efficiency of the HHG process. The use of a mirror
with focal length f = 75 cm allows us to reach an intensity at focus of 3 ·1014
W cm−2 (100μm waist), that is suitable for Ne, but too low for He that has
a ionisation saturation intensity almost twice as high compared to the one of
Ne ( 1.4 ·1015 W cm−2 for He compared to 8 ·1014 W cm−2 for Ne).
The choice of HHG gas target for the VUV pulse generation was restricted
to Kr and Xe, due to their low Ip that allowed the production of low harmonics
at 15-20 eV. Figure 3.19 shows that Kr was more efficient in the low harmonics
range in our experimental conditions.
Energy (eV)16 18 20 22 24 26 28
Inte
nsity
(arb
. u.
0
0.2
0.4
0.6
0.8
1KrXe
Figure 3.19: Kr (black) and Xe (dotted red) low harmonics comparison.
88 CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT
I performed measurement of the XUV and VUV HHG spectra as function
of each gas target position along the propagation axis, in order to optimise the
phase-matching conditions for the XUV and VUV pulses. Figure 3.20, shows
the results obtained.
Target position (mm)0 2 4 6 8 10 12 14 16
Ene
rgy
(eV
)
1618202224
Target position (mm)0 2 4 6 8 10 12 14 16
Ene
rgy
(eV
)
40
60
80
100
120
Figure 3.20: XUV (top) and VUV (bottom) spectra as a function of gas jet positionwith respect the focal plane (z = 0).
It can be seen that the XUV emission is optimised, (as described in section
2.3), after the focus (z = 0). On the other hand the VUV emission shows a
much weaker z-dependence, allowing the positioning of the two gas targets in
series, with the Kr gas jet first, 3 mm downstream from the focal plane, for
the production of the VUV pulse, and the Ne gas jet 7 mm downstream from
the focal plane for the production of the XUV pulse.
The NIR pulse compression and CEP optimisation was performed with a
pair of motorised wedges in the NIR beam (see figure 3.8) to fine tune the
material dispersion, while observing the XUV harmonics. In fact the cut-off
region is the most sensitive to the NIR pulse duration and CEP, and the NIR
intensity could be adjusted with an iris to set the cut-off to the desired spectral
region (90 eV).
Figure 3.21, shows the results obtained by measuring the XUV and VUV
CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT 89
spectra as a function of wedges position (i.e. glass insertion).
Glass insertion ( m)-100 -50 0 50 100
Ene
rgy
(eV
)
70
80
90
100
110
Glass insertion ( m)-100 -50 0 50 100
Ene
rgy
(eV
)
1618202224
Figure 3.21: XUV (top) and VUV (bottom) spectra as a function of glass insertionin the NIR beam.
It can be seen that for the XUV harmonics the choice of wedge position is
crucial in order to obtain an isolated XUV pulse. For the VUV spectra, no
CEP dependence is visible in this dataset. For this reason the NIR pulse CEP
was always optimised looking only at the XUV harmonics.
I then measured a series of spectra with the two pulsed valves either on or
off, so that the effect of each gas medium on the pulse generated in the other
gas jet could be verified.
The spectra in figure 3.22 show both the VUV range (left side) and the
XUV range (right). The color scale is the same for all spectra (note the x2
factor applied to some panels). For the XUV spectral region the cut-off of the
Kr harmonics (panel (d)) does not reach 90 eV, and therefore no interaction
is expected between the Ne and the Kr spectra at these energies. The signal
obtained with both gas targets on (panel (f)) is lower than when only the Ne
gas target is on (panel (b)), with an attenuation factor of about 2. However,
the signal for the VUV spectral range is much brighter and therefore the gas
pressure in the Kr gas target can be set to a lower value, depending on the
90 CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT
experimental conditions required.
(b)
x2
-5
0
5(d)
Div
erge
nce
(mra
d)-5
0
5(f)
x2
Energy (eV)50 100
-5
0
5
(a)
x2
-5
0
5(c)
Div
erge
nce
(mra
d) -5
0
5(e)
Energy (eV)15 20 25
-5
0
5
Figure 3.22: Interaction effects between the two gas targets. XUV HHG spectra onthe right, VUV on the left. In the top row (a)-(b), shows the spectra obtained withonly the Ne gas jet activated. Similarly the middle row (c)-(d) shows the spectraobtained with only the Kr gas jet on. the bottom row (e)-(f) shows the spectrameasured with the two gas jets operated simultaneously.
CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT 91
In the VUV range the production of sub threshold (below Ip) harmonics in
Ne is not efficient at all (panel (a)) and no significant interaction between the
Ne and Kr spectra is expected in this range. Running both gas targets at the
same time has a similar effect in the VUV range as it had in the XUV one, with
an attenuation of the Kr signal when the Ne gas jet is on. Comparing the Kr
only condition (panel (c)) and the condition with both gas targets activated
(panel (e)) shows an attenuation factor of about 2.
These results allowed me to develop a procedure for the optimisation of the
XUV and VUV pulse production. Since the XUV pulse production sets much
stricter generation conditions, both in terms of CEP and phase-matching, I
always optimised the XUV harmonics first (position and dispersion/CEP) and
then set the position of the Kr target to be few mm before the Ne target.
The effect of the Kr gas jet was tested also by comparing a CEP scan on
the XUV harmonics, with the Kr jet on and off. In figure 3.23 we can see the
results of a CEP scan similar to the one presented in figure 3.21, performed
with the Kr jet on (top) and off (mid). This time the CEP was modulated by
acting on the slow loop feedback signal, rather than moving the wedges. In
this way the dispersion experienced by the beam was not altered in any way
and the CEP effect be more easily analysed. Note how the cut-off maximum
position is not altered in the full 4π scan, in contrast with the data shown in
figure 3.21. By plotting the integrated signal around 90 eV (within the black
dashed lines) an average shift of 0.23±0.06π between the two measurements
(3 central maxima considered) can be extracted, that corresponds to the CEP
shift of the NIR pulse in the Ne target due to the presence of the Kr gas.
92 CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT
VUV on
0 0.5 1 1.5 2 2.5 3 3.5 4
Ene
rgy
(eV
)
80
100
VUV off
0 0.5 1 1.5 2 2.5 3 3.5 4
Ene
rgy
(eV
)
80
100
CEP ( )0 0.5 1 1.5 2 2.5 3 3.5 4
Cou
nts
(nor
mal
ised
)
0.5
1
CEP offset = 0.23 0.06
VUV onVUV off
Figure 3.23: HHG spectra as a function of CEP set on the slow loop feedbacksignal. The top panel corresponds to the case with both gas targets operating (VUVon). The middle panel corresponds to the case with only the Ne target operating(VUV off). The bottom panel shows the integrated signal around 90 eV, comparingthe VUV on case (solid blue) with the VUV off case (dashed red).
CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT 93
3.4 Plasma HHG
In this section I will present some results obtained in the experimental cam-
paign lead by PhD student Z. Abdelrahman (Imperial College) and in col-
laboration with Dr. R. Ganeev (Voronezh State University). The aim of the
campaign was to develop a high harmonics source based on ablation plumes
target rather than the more standard noble gas media.
3.4.1 Introduction
High Harmonics generation is a very promising method to extend the exper-
imental capabilities involving short wavelength coherent light. However the
low efficiency of the process can still be a limiting factor and the presence of
multiple harmonics is not ideal for some experiments where a specific spectral
region is of interest. For this reason, efforts are being made to optimise the
high harmonics photon yield and shape its spectral features. In this context,
high harmonics generation in ablation plumes has been developed as an alter-
native to the more standard noble gas media, extending the choice of targets
and showing some interesting spectral properties such as resonance-induced
enhancement of spectral portions of the HHG spectrum [107]. These charac-
teristics are of interest when looking for methods to develop ultrafast XUV
pulses, as they may provide naturally isolated spectral features, removing the
necessity of spectrally selecting a portions of the HHG emission either with
metallic filters or monochromators. Isolated spectral emission from ablation
plumes have been shown to occur not only at high energies (50 eV for Mn)
[108], but also at lower energies (20 eV for In) [33] and in some cases should
be able to support sub-fs pulse durations [24].
While the standard HHG spectrum is described by the 3-step model intro-
duced in 2.3, the resonance-induced enhancement in ablation plumes harmonics
can be described by the 4-step model [109]. While the first two steps (tunnel
ionisation and propagation in the continuum) remain the same, recombination
94 CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT
now happens in two steps. The electron interacts first with an autoionising
state (step 3) and then recombines with the parent atom (step 4) as shown in
figure 3.24
Figure 3.24: Four step model to explain the resonance-induced enhancement inablation plumes high harmonic generation. Reprinted figure with permission from[109]. Copyright 2010 by the American Physical Society.
It can be seen how, instead of directly recombining with the parent atom
(3* path) the electron wave-packet first recombines with the parent ion set-
tling in an auto-ionising state and from here relaxing to the ground state via
photoemission. As explained in [109], the 4-step model has comparable, or
even higher, probability with respect to the 3-step dynamics, due to the high
transition cross sections , which can be viewed as a resonant enhancement of
the process.
3.4.2 Experimental results
The experiments were performed at Imperial College in the beamline showed in
figure 3.15. In the HHG chamber a solid rotating target was positioned instead
of the gas target. Target rotation is necessary to have a new surface at each
laser shot, resulting in a more stable and stronger harmonics signal [110]. A
portion of the uncompressed beam from the CPA system is used as the ablation
CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT 95
pulse, with an energy of 120 μJ and duration of 23 ps. It is then focused with
a f = 40 cm lens to achieve an intensity of Iablation ≈ 8 · 109 Wcm−2. The
ablation pulse arrives first on the surface to produce the ablation plume that
is the target for HHG of the driving 3.5 fs NIR pulse 35 ns later.
In order to examine for the first time the spatial coherence of the high
harmonic emission from ablation plume targets, we inserted a double slit (50
μm spacing, 6 μm width) in the beam path (second chamber of figure 3.15),
and recorded the fringe pattern with the flat field spectrometer.
The degree of spatial coherence of the harmonic emission has been evalu-
ated with the visibility parameter:
V =Imax − Imin
Imax + Imin
(3.16)
With perfect coherence V = 1, while lower values of this parameter indicates
a lower level of coherence. In figure 3.25 typical results are shown.
For Zn and In (panels (a) and (c) of figure 3.25) the harmonics emission
shows the resonance feature introduced in the previous paragraph, with an
isolated bright emission at 18 eV in zinc and at 20 eV in indium. The en-
hancement at 18 eV is due to the overlap of the laser 11th harmonic (≈ 18
eV) with the 18.3 eV Zn III transition (3d10 → 3d9(2D)4p) [33, 111, 112].
The enhancement at 20 eV is due to the overlap of the 13th harmonic of the
laser (≈ 20 eV) with the 19.9 eV In+ ground to autoionising state transition
(4d105s2 1S0 → 4d95s2(2D)1P1) [33, 113]. Table 3.1 summarises the visibility
values obtained with the different targets.
Target VisibilityZn 0.74± 0.04In 0.66± 0.06
C (H13) 0.63± 0.03Ar (H15) 0.47± 0.08
Table 3.1: Visibility of harmonics generated in ablation plumes.
The reason for the presented values to be significantly lower than unity can
96 CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT
(a)Zn In
(c)
C(b) (d)
Ar
V=0.47V=0.63
V=0.66V=0.74
Figure 3.25: HHG spectra generated in ablation plumes of zinc (a), carbon (b)andindium (c). For comparison the harmonics produced in argon are shown in (d).The interference pattern is obtained with a pair of slits inserted in the beam path.Each panel shows the integrated spectrum (below), and a line-out of the interferencepattern on the right. Adapted from [33].
be attributed to the input coherence of the laser beam. The visibility of the
interference pattern of the q-th harmonic can in fact be computed to be [114]:
Vq = 1− q(1− V1), (3.17)
where V1 is the fringe visibility of the fundamental beam. A driving beam
with V1 = 0.98 is enough to lower the visibility of the harmonics to the levels
measured. The mechanism lowering the driving beam visibility can be due to
non-linear propagation effects in the path to the interaction region (i.e. in the
air path or at chamber entrance window).
The target with the highest visibility is Zn. The degradation of visibility for
CHAPTER 3. ULTRAFAST LIGHT SOURCES DEVELOPMENT 97
the other targets can be attributed to an increase in the free electron density
in the interaction region. The presence of free electrons can lower the spatial
coherence of the beam due to a rapidly varying refractive index across the beam
profile [115]. ADK simulations confirmed that the free electron population in
Ar can be up to three times higher than in Zn [33].
In conclusion we showed that the spatial coherence of harmonics generated
in plasma plumes of C, Zn, and In, is comparable to that of standard har-
monics generated in Ar. This conclusion implies that harmonics generated in
plasma plumes are suitable for experiments requiring high spatial coherence,
for example diffraction imaging [116]. This result confirm the interesting fea-
tures of harmonics radiation produced in plasma plumes, and the possiblity of
using this type of source as a valid alternative to more standard HHG sources.
99
Chapter 4
New methods for attosecond
pump-probe experiments
The first two experiments presented in this chapter are focused on the charac-
terisation of short pulses in the few femtosecond range. As already introduced
in section 2.2, the characterisation of ultrafast pulses is a challenging task [15].
More and more sophisticated pulses can nowadays be produced [16] and they
are implemented in experiments heavily dependent on the precise waveform of
the electric field [3, 117]. For this reason, the development of new characterisa-
tion techniques is driven mostly by two factors. On one hand, the simplicity of
the implementation is essential to have easy access to the most important char-
acteristics of an ultrafast pulse. On the other hand, some experiments require
high accuracy in the pulse characterisation, due to the fact that the precise
waveform of the pulse applied to the experiment is critical for the dynamics
under investigation.
I will present some new developments of the dispersion scan “d-scan” tech-
nique [17, 118], an example of a simple experimental setup able to characterise
few cycle pulses.
Then I will present the Attosecond Resolved Interferometric Electric field
Sampling (ARIES) technique, an example of a powerful new technique for the
precise characterisation of the full carrier waveform of a pulse.
100 CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS
I will then describe the design of an electron velocity map imaging spec-
trometer and ion time-of-flight side-by side diagnostic. This device has re-
placed the electron time-of-flight spectrometer used to perform the streaking
experiments of the VUV and XUV pulses.
4.1 Dispersion-Scan
4.1.1 Standard d-scan
The basic idea behind the d-scan technique is to use the dependence of a
non-linear process, for example SHG, on both the spectral amplitude and
spectral phase of the pulse under investigation [17]. As the name indicates,
it is necessary to scan different amount of dispersion (i.e. input phase) for a
given pulse. The simplest way to implement this scan is with glass wedges and
a motorised translation stage. Depending on the wedges position the pulse
travels through a different amount of material, and therefore experiences a
different amount of dispersion as shown in equation (2.10). In this case the
only adjustable parameter available is L, the length of dispersive medium the
pulse has to travel through, and the dispersion applied is determined by the
type of material chosen. A more sophisticated way to introduce an arbitrary
amount of dispersion on a pulse is via an acusto-optic modulator [119], where
the spectral phase shape can be defined in a more general way (for example a
purely quadratic phase can be imposed to the pulse).
Regardless of the method chosen to perform a d-scan, it is necessary to
measure the non-linear signal spectrum multiple times, once for each change
in dispersion, and then feed the spectra obtained to an iterative algorithm for
the extrapolation of the spectral phase and amplitude corresponding to the
measured data. Performing this measurement can be straightforward. It is
possible to use SHG and a simple 1-D spectrometer to obtain the non-linear
signal spectra as a function of insertion of a pair of motorised wedges. All
CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS 101
these elements are usually already present in an ultrafast laser beamline, so
no particular beam manipulation is required for the pulse measurement. The
non-trivial part of the pulse characterisation is the iterative algorithm required
to find the spectral amplitude and phase that correspond to the measured
trace. In figure 4.1 it can be seen how the matching between measured (a)
and retrieved (b) traces is the first indication of the robustness of the retrieval
process, as in the FROG technique already introduced. Moreover the algorithm
is being further developed and studied to determine its capabilities and limits.
One useful feature of the algorithm developed so far is that it is capable of
dealing with partial traces [118] and an unknown spectral response curve in
the measured signal, due either to phase-matching conditions or experimental
constraints (i.e. spectral response of the spectrometer).
Figure 4.1: Example of pulse characterisation with the d-scan technique. Measuredtrace (a), retrieved trace (b), spectral (c) and temporal (d) properties of the pulse.Adapted from [17].
4.1.2 Single shot implementation
In the process of developing the d-scan technique, I designed an experimental
setup capable of measuring the required spectra for the d-scan technique in
102 CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS
a single shot basis in collaboration with Helder Crespo, Fransico Silva and
Warein Holgado from the Department of Physics & Astronomy and IFIMUP-
IN (University of Porto). The experimental results were obtained in a joint
experimental campaign in Porto. The laser system is similar to the one avail-
able at Imperial College and delivers a few cycle pulse after hollow core fibre
spectral broadening and chirped mirror compression of a Ti:Sapphire CPA sys-
tem [120]. The single shot d-scan implementation is of particular interest to
make the technique more general, e.g. for use with low repetition rate laser
systems, where a shot-to-shot analysis of the experimental data is sometimes
necessary.
As in most single shot measurements, we increased the dimensionality of
the measured data to map the repeated measurement onto an axis experimen-
tally measurable in single shot mode. For example in the single shot FROG
implementation, the delay axis is mapped onto the spatial axis of an imaging
spectrometer [121]. To implement this idea in the d-scan technique we decided
to apply different amount of dispersion to different spatial portions of the beam
and use an imaging spectrometer to measure the dispersion dependent spec-
tra as a function of spatial position. We used a BK7 Littrow prism to insert
different amount of glass at different spatial positions. Figure 4.2 shows the
optical characteristics of this element on the beam.
The first plot 4.2(a) shows the ray-tracing calculations I performed to ob-
tain the data presented in the following plots In 4.2(b) it can be seen how the
introduced dispersion is linear with respect the spatial position on the prism
entrance face. The angular dispersion due to refraction is not detrimental,
as a spectrum in the 400-1100 nm range has a total divergence of only 1.1◦
(19 mrad) as shown in 4.2(c). Since the d-scan is mapped on the spatial pro-
file of the beam it is now necessary to use an optical system to image the
beam onto the SHG crystal and then onto the imaging spectrometer. The
experimental setup, shown in figure 4.3, needs to be able to handle the spa-
tial properties of the beam very precisely in order to preserve the spatially
CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS 103
posi
tioin
(mm
)
0
20
40
60
80(a)
(nm
)
400
500
600
700
800
900
1000
1100
position (mm)10 20 30 40 50
GD
D (f
s2 )
500
1000
1500 (b)
(nm)400 600 800 1000
OU
T (deg
)
0
0.2
0.4
0.6
0.8
1(c)
Figure 4.2: BK7 Littrow prism used for the single shot d-scan. In (a) it is possibleto see how ray at different positions travel through different amount of glass. At theoutput surface there is no spatial dispersion as the beam enters the prism first faceperpendicularly. The range of GDD introduced as a function of position shown in(b) is enough to record a full d-scan trace. The angular dispersion is shown in (c)where θOUT is referenced to the angle of diffraction of λ = 400 nm.
varying dispersion from the prism to the imaging spectrometer. For this rea-
son the first manipulation to the beam is an astigmatism-free [122] reflective
beam expander (Telescope M1/M2 in figure). In this way I ensured spatial ho-
mogeneity of the beam, thus preventing spatio-temporal coupling that would
result in ambiguous traces (different pulses at different spatial positions). An
iris was used to select an 8 mm diameter section of the central part of the
expanded beam. The output surface of the Littrow prism was then imaged
onto the SHG generation crystal (10 μm thick BBO crystal) with a f=45cm
focusing mirror (imaging M1). This first imaging system, with a magnifica-
104 CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS
tion factor M=-0.33, not only mapped the dispersion information correctly to
the SHG crystal, but also allowed us to reach enough intensity in the image
plane to obtain a detectable second harmonic signal. A second imaging system
(Imaging M2, f=50cm M=-0.64) delivered the second harmonic signal to the
astigmatism-free [123] imaging spectrometer. From figure 4.3 it can be seen
how, with a flip mirror, it was possible to have a parallel measurement of the
pulse duration with a standard d-scan setup.
1D spectrometer
Imaging spectrometer
Standard D-scan
Flip M
Telescope M1
Telescope M2
Littrow Prism
Imaging M1
Imaging M2
BBO
BBO
1mJ 30fs 1kHzFemtolaser
Laser set-up
Figure 4.3: Experimental setup for the single shot implementation of the d-scantechnique. See text for details. Note the flip mirror (Flip M) allowing an easycomparison between the single shot implementation, and the standard d-scan.
The calibration for the dispersion axis of the standard d-scan setup consists
simply in mapping the phase introduced by the material used, to the wedges
position, and can be therefore considered completed once the geometry of the
wedges is known together with the material properties. For the calibration of
the single shot implementation, we measured a number of traces at different
wedges position, thus shifting the overall trace in the dispersion direction and
obtaining a pixel-to-dispersion calibration as shown in figure 4.4.
CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS 105
(a)
Lambda (nm)350 400 450
Pix
#100
200
300
(b)
Lambda (nm)350 400 450
Pix
#
100
200
300
Glass insertion (stage steps)80 90 100 110 120 130 140 150 160
Pix
#
100
150
200
250(c)
Peak positionLinear fit
Figure 4.4: Calibration of the dispersion axis for the single shot implementation ofd-scan. Traces are recorded as a function of glass insertion. (a) and (b) are the twoextrema of the calibration scan, showing how the trace is moving downwards. (c)shows the linear fit between pixel and glass insertion that calibrates the dispersionaxis. the error bars correspond to ±3σ to make them more visible.
4.1.3 Results
The measured traces are presented in figure 4.5. In the left column is plot-
ted the measured data with the scanning technique (top) and the single shot
implementation (bottom). On the right hand side the corresponding retrieved
traces are presented.
Comparing the top two traces of figure 4.5 it can be seen how the algorithm
reproduces accurately the measured scanning trace. In the single shot case
(bottom row), the camera sensitivity below 320 nm was very poor, resulting in
lack of signal with respect to the scanning technique, where the spectrometer
was able to measure signal down to 300 nm. In any case, the retrieval algorithm
can cope with partial traces, and managed to retrieve a trace similar to the
scanning measurement.
In figure 4.6 I show the results of the retrieval algorithm analysis performed
by F. Silva comparing the temporal profile and spectral phase obtained from
the single shot and the scanning data.
106 CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS
Scanning M.
BK
7 in
serti
on (m
m)
-2
-1.5
-1
-0.5
0
0.5
1
1.5
2Scanning R.
BK
7 in
serti
on (m
m)
-2
-1.5
-1
-0.5
0
0.5
1
1.5
2
Single Shot M.
Wavelength (nm)300 350 400 450
BK
7 In
serti
on (m
m)
-2
-1.5
-1
-0.5
0
0.5
1
1.5
2Single Shot R.
Wavelength (nm)300 350 400 450
BK
7 In
serti
on (m
m)
-2
-1.5
-1
-0.5
0
0.5
1
1.5
2
Figure 4.5: Comparison between the scanning (top) and single shot(bottom) mea-sured (left) and retrieved (right) traces. Analysis by F. Silva
The main result from the comparison between the two temporal profiles
obtained is that they are compatible, within the retrieval error, with a pulse
duration of 3.2±0.1 fs for the scanning technique, and 3.3±0.3 fs for the single
shot measurement. The shaded area around the single shot data represents
the standard deviation between multiple retrievals run with different initial
parameters (64 retrievals in total, with different optimisation variables). The
main discrepancy between the two techniques is the modulation of the spectral
phase. The retrieved phase obtained from the single shot dataset (solid blue
line) is the average of the 64 retrievals performed. Some single shot retrievals
reproduce such oscillations, but the average over all of them washes out such
oscillations. Note the shaded area has an amplitude comparable to the am-
plitude of the oscillations measured with the standard scanning method. A
CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS 107
Pha
se (r
ad)
-3
-2
-1
0
1
2
3(a)
Single ShotScanning
Wavelength (nm)500 600 700 800 900 1000
Inte
nsity
(arb
. u.)
0
0.5
1(b)
Time (fs)-20 -10 0 10 20
Inte
nsity
(arb
. u.)
0
0.2
0.4
0.6
0.8
1
3.3 0.3 fs(Single Shot)
3.2 0.1 fs (Scanning)
(c)
Figure 4.6: Spectral phase (a) and corresponding temporal profile (c), obtainedfrom the single shot d-scan (solid blue lines) and the standard scanning d-scantechnique (dashed-red lines). the input spectrum is shown in (b). the shaded areais the standard deviation of the single shot measurement, obtained from differentretrievals settings.
rigorous method to choose one particular set of retrieval parameters, rather
than average over them, is yet to be determined and is currently under inves-
tigation by F. Silva and co-workers.
In conclusion, the experimental results confirmed the validity of the single
shot implementation. The quantitative agreement between the single shot im-
plementation and the standard technique is satisfactory with a pulse duration
of 3.3±0.3 fs retrieved in the single shot measurement, and 3.2±0.1 fs in the
scanning measurement. More work in the retrieval procedure is necessary to
define a robust way to select a set of optimisation variables representing the
phase information without ambiguities.
While the results presented can be considered a proof-of-principle of the
108 CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS
single shot implementation of the d-scan technique, they also pointed to the
aspects that should be improved in the future. To begin with, a more compact
design of the experiment would be desirable, as with the current focusing optics
the beam path in the single shot implementation, from the Littrow prism to the
imaging spectrometer was ≈ 4m. On one had this made the alignment easier,
as the image plane could be found manually without the need of translation
stages. On the other hand the use of shorter focal length optics would allow
the design of a more compact setup with an easier handling of the dispersed
beam after the prism (in our setup the beam filled almost fully the imaging
mirror M1). Moreover an imaging system with a shorter focal length would
relax the intensity constraint at the BBO crystal, since a smaller spot-size
could be achieved.
Another aspect to consider for the further development of the single shot
implementation of the d-scan technique is related to the dispersion range re-
quired to characterise a pulse. In fact, characterising a few-cycle pulse requires
a smaller dispersion range compared to a longer pulse. To make the single shot
implementation possible for longer pulses it may be necessary to adopt a more
dispersive material for the Littrow prism.
In general, the single shot implementation of d-scan maintains all the ad-
vantages of the scanning technique, since no splitting of the pulse and no
temporal overlap is required for the measurement to be taken. The alignment
of the imaging optics can be performed in a straightforward manner since it
only requires finding the image plane of the dispersive element (in our case the
Littrow prism) and of the BBO crystal. The iterative algorithm necessary to
retrieve the pulse duration is becoming more and more robust, with the pos-
sibility of coping with partial traces [118], making the d-scan technique and
its single shot implementation a viable alternative characterisation technique
with respect the more standard ones based on FROG or SPIDER.
CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS 109
4.2 Attosecond Resolved Interferometric
Electric-field Sampling
With the development of more and more complex pulses [16], one of the main
challenges in ultrafast pulse characterisation is the retrieval of the complete
field waveform. The characterisation techniques presented so far can only
characterise the spectral phase from the second order onwards (see equation
(2.9)). For this reason, different methods have been developed to characterise
ultrafast pulses more precisely, for example retrieving the CEP of a pulse or
even the full carrier waveform information [18, 60, 124]. Apart from a few
recent developments [125], such measurements usually rely on HHG [18] or
photoelectron spectroscopy [124]. In the case of HHG, it is possible to modify
the CEP value looking at the continuum cut-off and attribute CEP=0 to the
position corresponding to the smoothest and highest cut-off [126], as shown in
figure 4.7.
Glass insertion ( m)-50 0 50
Ene
rgy
(eV
)
70
75
80
85
90
95
100
105
110
0 0.5 1
CEP=0CEP= /2
Figure 4.7: CEP scan showing how it is possible to distinguish pulses with CEP=0with highest and smoothest cut-off (dashed black line) from pulses with CEP=π/2with lower and modulated cut-off (red dotted line).
While this is a reliable method for optimising the generation of isolated
110 CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS
attosecond pulses, it does not provide a full pulse characterisation and, until
recent developments [18], the only way to obtain the full waveform of an elec-
tric field was with a photoelectron spectroscopy technique known as attosecond
streaking [127]. This technique is a powerful method for ultrafast pulse charac-
terisation and will be presented in detail in chapter 5. However, the detection
of photoelectrons is technically demanding as it usually requires a dedicated
experimental vacuum chamber and appropriate electron detectors. For this
reason the development of other techniques for the full characterisation of the
electric field waveform not relying on photoelectron spectroscopy are of par-
ticular interest, especially if it can be based on equipment already necessary
for the characterisation of the HHG radiation, such as an XUV spectrometer.
I will present some results obtained in our laboratory at Imperial Col-
lege obtained in collaboration with Adam Wyatt, Andrea Schiavi and Ian
Walmsley from the Clarendon Laboratory (University of Oxford). We de-
veloped the Attosecond Resolved Interferometric Electric-field Sampling tech-
nique (ARIES), an all optical ultrafast pulse characterisation technique.
4.2.1 Concept
ARIES uses the modulation of the HHG cut-off to track the instantaneous
waveform amplitude of the field. As shown in figure 4.7, the HHG cut-off
is strongly dependent on the exact shape of the generating waveform. It is
possible to exploit this dependence to extrapolate the full electric field. Let
us consider two pulses, linearly polarised along the same axis, one driving
the HHG process, that I will call the probe-pulse, and one playing the role
of the pulse to characterise, defined as the test-pulse. These two pulses are
combined coherently in the interaction region of the HHG process. A time
delay can be introduced between the two, and HHG spectra can be recorded
as a function of this delay. If the probe-pulse driving the HHG process is
a few-cycle pulse, the resulting HHG cut-off is determined in the sub-cycle
time interval occurring in the more intense half-cycle of the laser pulse. The
CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS 111
interference between the test and probe pulse occurring at the most intense
half-cycle of the probe-pulse will therefore modulate the cut-off position with
femtosecond to attosecond time resolution, corresponding to the time window
over which the cut-off is generated and emitted.
From a semi-classical point of view, ARIES exploits the fact that the cut-
off emission happens for a very precise electron trajectory. The interference
between the test and probe pulses modifies the instantaneous intensity of the
waveform, leading to a shift of the cut-off position. When the interference is
constructive (destructive), the cut-off is shifted to higher (lower) energies as
shown in figure 4.8.
Times (fs)-8 -6 -4 -2 0 2 4 6 8
Am
plitu
de (a
rb. u
.)
-1
-0.5
0
0.5
1 (a) Probe pulseTest pulse 1Test pulse 2
Harmonic Order45 50 55 60 65 70 75 80 85 90
Am
plitu
de (a
rb. u
.)
0.4
0.5
0.6
0.7
0.8(b)
Figure 4.8: Aries concept. The probe pulse, solid black line in (a), driving the HHGprocess, interferes with the test pulse. For constructive interference (test pulse 1,blue-dashed line) in the high amplitude region of the probe-pulse (grey shaded area),the HHG cut-off is shifted to higher energies as shown in the corresponding spectrum(blue-dashed line and shaded area) presented in (b). For destructive interference(red-dotted line) the opposite happens with a shift of the cut-off to lower energies.Data courtesy of A. Wyatt.
This is, of course, a simple model for the treatment of HHG, but both
112 CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS
SFA (strong filed approximation) simulations (performed by A. Wyatt) and
semi-classical simulations (performed using a code I developed), show similar
results, proving that the main dynamics involved in the HHG cut-off shifting
are mainly driven by the interference process as described above. Moreover,
the correct retrieval of the test-pulse obtained from the cut-off position proves
that the mapping between these two quantities (cut-off shift and waveform
amplitude) can be considered linear. Some simulations results are shown in
figure 4.9, where two test pulses (white overlay) are correctly mapped by the
cut-off position both by an SFA code in (a), and by a classical trajectory code
in (b).
(a)
Delay (fs)-5 0 5
Ene
rgy
(eV
)
100
110
120
130
140
150
160(b)
Delay (fs)-5 0 5
Ene
rgy
(eV
)
140
145
150
155
Figure 4.9: Aries traces obtained with an SFA code (a), and a classical trajectorycode (b). SFA data courtesy of A. Wyatt. The white line in overlay is the inputtest-pulse, correctly mapped in both cases by the cut-off position.
4.2.2 Experimental setup
The experimental implementation of the ARIES technique requires combining
the test-pulse and the probe-pulse in the interaction region (gas target) for
HHG with attosecond resolution. This was achieved with a Mach–Zehnder
interferometer positioned after the hollow fibre setup of our laboratory (see fig
CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS 113
3.8). The few cycle pulse after hollow fibre pulse compression was used as the
probe-pulse. As shown in figure 4.10, a beam-splitter was used to split 10%
of the beam for the test-pulse which passed through a pair of wedges before
being recombined with the probe-pulse with another 10% beam-splitter (i.e.
the test pulse was 1% of the probe-pulse).
HHGFlat field
spectrometer
test-pulse
probe-pulse
delay
BS BSW1
W2
3.5 fs 0.5 mJ
Figure 4.10: Aries setup. The fibre output was delivered to a Mach-Zehnderinterferometer. The test-pulse is obtained from the reflection of two 10% beam-splitters. The probe pulse is delivered to a double stage (mechanical plus piezo)to obtain the necessary high precision, long delay line. The two pulses were thenrecombined in the second beam splitter and focused in the HHG chamber.
The probe-pulse compression and CEP control was performed with a pair
of fused silica wedges before the interferometer and after the chirped mirrors
by looking at the HHG emission produced with the probe-pulse only. The
test-pulse dispersion and CEP was controlled with the second pair of wedges
(W2) positioned in the test-pulse arm of the interferometer. This allowed us to
tailor different test-pulses to be retrieved with the ARIES technique. Precise
temporal delay between the two pulses was achieved with a piezo stage (Physik
Instrumente P-753 Lisa 50 pm resolution over 28 μm travel range) positioned
in the probe-pulse arm of the interferometer. This piezo stage was mounted on
top of a coarser stage (Thorlabs PT1-Z8, 200nm resolution over 25 mm travel
range) to obtain at the same time high stability and long delay range.
To test the ARIES technique capabilities we measured different test-pulses
114 CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS
obtained with different amount of dispersion. The wedge dispersion in the
test-pulse arm was calibrated via spectral interferometry and therefore we
can compare the expected effects of dispersion (CEP shift and chirp on the
waveform) with the measured one.
The first results I present are the measurement of test-pulses tailored so
that they had the same duration but different CEP. These test-pulses were
obtained with very small wedge displacement. In fact to achieve a CEP shift
of 2π it is necessary to insert ≈ 56 μm of fused silica, changing the pulse
duration of a pulse at 790 nm from 3.5 fs to 3.9 fs. The results obtained are
shown in figure 4.11.
On the left-hand side the raw, spatially integrated, spectra are shown,
showing modulations both in amplitude and in the cut-off position. The am-
plitude modulations are attenuated on the right column by normalising the
spectrum at each delay to unity. This allows an easier determination of the
cut-off position that is marked by the black line. It can be seen how the CEP
of the pulse changes from top to bottom performing a full 2π cycle. Each step
correspond to π/2 and it is possible to recognise the different sin-like and cos-
like shapes of the waveform. The sensitivity of the technique to the electric
field waveform is clearly evident.
CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS 115
Delay (fs)-8 -6 -4 -2 0 2 4 6 8
110115120125
110115120125P
hoto
n en
ergy
(eV
)
110115120125
110115120125
Delay (fs)-8 -6 -4 -2 0 2 4 6 8
110115120125
Delay (fs)-8 -6 -4 -2 0 2 4 6 8
110115120125
110115120125 P
hoto
n en
ergy
(eV
)
110115120125
110115120125
Delay (fs)-8 -6 -4 -2 0 2 4 6 8
110115120125
Figure 4.11: Aries CEP measurement. Test pulses with different CEP are suc-cessfully characterised. Each row corresponds to a π/2 shift in CEP. On the leftis the raw, spatially integrated, spectrum, showing the cut-off energy and intensityfluctuations. On the right the same data is scaled to unity per each delay, enhancingthe energy shift visibility of the cut-off. Analysis of A. Wyatt
116 CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS
We then proceeded to introduce an even higher amount of dispersion in
order to significantly modify the test-pulse duration. In figure 4.12 the results
of such measurements are shown.
Time (fs)-50 0 50
Am
plitu
de (A
rb. u
.)
(a)
Wavelength (nm)500 600 700 800 900 1000
Pha
se (r
ad)
-30
-25
-20
-15
-10
-5
0
5
10
15(b)
Figure 4.12: Aries dispersion measurement. Test pulses with different dispersionhave been characterised. (a) is the collection of different test pulses retrieved. (b) isplotted the corresponding phase measured (solid line) and the expected one (dashed)according to the amount of glass inserted. The confidence interval plotted correspondto ±σ. In overlay (solid blue line) is the retrieved spectrum. The order of the pulsesin (a) is the same as the phases shown in (b). The third pulse from the top has beenpicked as reference for the phase calculations. Analysis of A. Wyatt
CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS 117
In figure 4.12(a) are plotted the retrieved waveforms of a series of test
pulses. The analysis of the waveforms allowed us to extract the spectral phase
of each of them and compare it with the expected phases provided by the glass
inserted with the wedges pair. This comparison is shown in 4.12(b), where the
retrieved spectral phase is plotted in solid lines, and the calculated phase from
the glass insertion is plotted in dashed lines. The confidence interval plotted for
each phase in red lines corresponds to the RMS around the expected dispersion
(solid black line), weighted on the retrieved spectrum (shown in overlay solid
blue line).
The agreement between the two data series is good showing the accuracy
of the ARIES technique.
In conclusion ARIES successfully characterised the complete electric field
of pulses with different CEP and different chirps and is a promising method
for the characterisation of ultrafast pulses waveforms without the need of an
attosecond streaking setup.
A valuable aspect of the ARIES technique is the fact that it characterises
the pulse in the interaction region dedicated to the HHG process. For other
techniques the difference in dispersion between the beam path to the charac-
terisation set-up, and to the experimental setup has to be taken into account,
and therefore the pulse used in the actual experiment must be calculated from
the pulse characterised by applying the expected amount of dispersion expe-
rienced on the way to the experimental chamber. With the ARIES technique,
on the other hand, the pulse is already characterised at the interaction region,
giving direct access to the waveform that will be used for HHG.
The data acquisition speed is another interesting aspect of the ARIES
technique. In principle it is possible to record HHG spectra on a single shot
basis. To improve the signal to noise level the HHG signal can be integrated
for longer. To perform a delay scan of 30 fs, with 0.1 fs step size, integrating
for 1 second the image at each delay step (1000 laser shots at 1 kHz repetition
rate), the total integration time required would be of just 5 minutes.
118 CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS
Some aspects of the technique are to be further investigated. For example
it would be interesting to verify the range of test-pulse intensities for which
ARIES is still applicable. In the experiment presented, a test-pulse of 5 μJ
has been characterised with a probe-pulse of 500 μJ. In principle the ARIES
technique can be scaled to lower energies using a tighter focus for the HHG.
Regarding the limitations on the test-pulse bandwidth and duration, the results
presented have shown that the ARIES technique can characterise long pulses,
as the most chirped pulse presented in figure 4.12 has a duration of ≈ 18 fs and
the carrier modulation were measured in a 40 fs range. Therefore, from this
point of view, it seems that the maximum duration measurable is limited to
the precision of the delay line, since attosecond resolution is required at each
time step.
Regarding the measurable bandwidth with the ARIES techniques, the re-
sults presented indicate that it is possible to measure a bandwidth comparable
to the one of the probe-pulse. However the technique seems sensitive to higher
frequencies. Classical simulations, shown in figure 4.13, predicts the possibility
of extracting a field with spectrum centred at ω0test = 2ω0probe .
In the simulation a 3.5 fs pulse centred at 800 nm was used as probe-pulse.
A pulse centred at 400 nm and with 30fs3 chirp was used as test-pulse. The
computed trace shown in figure 4.13(a) shows the expected oscillations at 2ω0.
However a delay can be noticed between the carrier of the test-pulse (plotted
in overlay) and the edge of the signal. This difference is more evident in figure
4.13(b) where the temporal profiles of the probe-pulse (dashed blue), of the
test-pulse (solid red) and of the retrieved pulse (dotted black) are shown. This
delay may be due to the fact that the timing of the trajectory responsible for
the highest photon energy does not correspond to the peak of the envelope
of the probe-pulse. Nevertheless the spectral properties of the test-pulse are
retrieved. This is of particular interest as it would open the possibility of a
direct characterisation of the pulses used in two color (ω + 2ω) schemes [128,
129], or with extreme bandwidths [16].
CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS 119
test-p
(a)
Ene
rgy
(eV
)
140
142
144
146
148
150
152
Delay (fs)-10 -5 0 5 10
Am
plitu
de (b) probe-ptest-pretrieved
0 0.5 1 1.5 2 2.5 3
Inte
nsity
00.5
11.5
(c) probe-ptest-pretrieved
Figure 4.13: Semi-classical simulation of an ARIES measurement with a test-pulsewith a central frequency corresponding to the second harmonic of the probe-pulse.(a) Shows the computed trace, with in overlay the test-pulse. In (b) the temporalprofiles of the pulses are shown. A delay between the input test-pulse and theretrieved pulse can be noticed. In (c) are plotted the spectral properties of thepulses.
120 CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS
4.3 Electron Velocity Map Imaging and ion
time-of-flight
In this section I describe the development and design of a dual [130] electron
velocity map imaging (VMI) spectrometer and ion time-of-flight spectrometer
(see figure 4.14) that was installed in our beamline, replacing the electron time-
of-flight spectrometer used to record the streaking traces presented in chapter
5.
e-
i+
ion TOF MCP
electron VMI imaging MCP
repellerextractorcorrector
a) b)
Figure 4.14: Schematics (a), and a picture (b), of the installed dual electron VMIand ion TOF spectrometers. The top part is the VMI side, with the imaging MCPphosphor screen read by a camera mounted on the lid of the chamber. At the bottom(not visible) is the MCP dedicated to the detection of the ions hits.
This device allows simultaneous VMI and TOF measurements, thus allow-
ing, for example, covariance analysis of the recorded signals. The covariance
mapping technique [131] has been demonstrated useful in deconvolving com-
plex dynamics, by decoupling signals originating from different channels of the
dynamics under investigation [132].
4.3.1 VMI background theory
With the existing electron time-of-flight spectrometer, only the photoelectrons
with momentum pointing towards the TOF aperture are recorded. This allows
CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS 121
for a high angular resolution at the price of a low collection efficiency (accep-
tance angle 7.85 · 10−3 sterad, 0.25% of the full 4π angle). To overcome this
limitation an electron VMI was implemented. It also allows the measurement
of the full 3-D momentum distribution from a 2-D projection [133]. This pro-
jection is performed with a set of electrodes, and the electrons are detected on
an imaging MCP. The projection process is described in figure 4.15. Assum-
ing an initial electron distribution �p(px, py, pz), the transformation providing
the 2-D distribution on the detector P (xd, zd) is known as an Abel transform
[134]. While the projection action does not require particular assumptions,
the inverse procedure requires a degree of symmetry to recover the full 3-D
information. Assuming cylindrical symmetry around an axis in the xz plane
allows an Abel inversion to be performed, the transformation providing �p from
P (xd, zd).
x
y
z
Abel transform
Abel inversion
3D 2D
3D 2D (plus symmetry)
L
Figure 4.15: Concept of Abel transform and inversion, applied to retrieve the3-D momentum distribution p from the measured 2-D projection P (xd, yd) on thedetector plane.
In the case of a constant �E field applied to the electrons, the position on
the detector plane is related to the initial kinetic energy by
KE =p2x2me
+p2z2me
=eE
4L(x2d + y2d) (4.1)
This relation allows the distribution, measured in pixels, to be converted
122 CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS
into the momentum distribution using an Abel inversion algorithm. I used a
PBASEX [135, 136] algorithm implementation, developed by former Imperial
College PhD student M. Siano. It is an efficient method as it describes the 3-D
momenta angular distribution in the natural Legendre polynomial basis (and
spherical coordinates). The projected image is fitted with a set of functions
defined as [135]:
f(k,l)(R, θ) = e(R−Rk)2
2σ Pl(cos θ). (4.2)
This basis is convenient since common processes such as single photon ionisa-
tion of a randomly aligned target (atom or molecule) have an angular distri-
bution given by [137, 138]:
P (θ) ∝ 1 + β2P2(cos θ) (4.3)
where θ is the angle between the polarisation vector and the direction of the
ionised electron. For this reason a limited number of Legendre orders (0 and
2) need to be included in expansion (4.2). Note that to ensure a non-negative
cross-section at every θ, the value β2 is limited in the range [−1, 2], where
β2 = −1 means electron ejection peaked along the plane orthogonal to the
laser polarisation, β2 = 0 means uniform emission, and β2 > 0 corresponds
to emission peaked along the polarisation axis. Figure 4.16 shows simulated
images for different β2 values.
4.3.2 Design
The design of the VMI spectrometer was based on an existing VMI instrument
at Artemis, Central Laser Facility, Rutherford Appleton Laboratory, UK, and
was optimised for resolving electrons in the 5-90 eV kinetic energy range. This
range is chosen based on the photon energies provided by the available VUV
and XUV pulses (see 5), and assuming the ionisation of small molecules with
an Ip of few eV (see chapter 6).
CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS 123
0 5 10 15 20 25 30 35
Figure 4.16: Simulated VMI images for different β values. Each simulation con-sists of 1E6 particles with angular distribution set by the β parameter and spatialdistribution given by a 3D Gaussian with (σx, σy, σz) = (1000, 5, 5)μm
The design was optimised by simulating different photoelectron distribu-
tions with Simion R©, a program dedicated to the simulation of electric and
magnetic fields once the geometry and voltage of the electrodes is given. The
expected projections of the electrons distribution were therefore obtained tak-
ing into account the geometry of the electrodes and the consequent electric
field modulations. The position, size and voltages of the electrodes can be
then optimised to achieve a resolution limited to the pixel size of the camera
used to record the spatial distribution of the electrons. In fact the simple model
presented in the previous paragraph does not take into account that the parti-
cles do not originate from a point-like source. This means that particles with
different initial kinetic energies may arrive in the same detector positions and
equation (4.1) would not hold. For this reason a focusing electrode is added
in order to minimise the spreading due to the initial spatial distribution.
Once the VMI geometry was chosen, minimal modifications were required
124 CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS
to include the ion time-of-flight spectrometer. I will only present the final
design, where we reached a reasonable trade-off between VMI performance,
ion TOF resolution and the voltages required. The resolution of the VMI
spectrometer is in fact lowered by the presence of the aperture for the ion TOF
spectrometer. The presence of this aperture does not completely screen the
electrons from the voltages applied on the ion TOF side. Applying a mesh to
lower the penetration of the field between the two spectrometers would result
in a lower collection efficiency for the ion TOF. Applying the technique of
covariance mapping to measurements biased by different collection efficiency
is detrimental, and therefore the option of using a mesh was discarded. In
figure 4.17 the set of electrodes simulated in Simion is shown, together with a
summary of the device performance. D. Walke in collaboration with Dr. T.
Barillot found the necessary technical solutions and design for the construction
of this diagnostic.
On the left of figure 4.17 a 3D rendering of the simulated electrodes can be
seen. A section of these electrodes is presented on the top plot 4.17(a). The
voltages have been chosen to obtain a grounded interaction region (at 98.5
mm in the plot). This will simplify the design of any target delivery system
to the interaction region. In fact, to minimise field distortions at the interac-
tion region, any external component should be introduced at the potential for
the spatial region it occupies. Grounding the interaction region means that
components placed in the interaction region (e.g. gas needles) will be close
to ground as well. A consequence of this choice is that the imaging MCP is
floated at 6 kV, while the MCP for the ion TOF is floated at -3kV. The two
electrodes around the interaction region are called the repeller and the extrac-
tor (from an electron point of view) and are held at ±333V. The repeller on
the ion TOF side has a smaller aperture than the other electrodes in order
to better shield the VMI side from the penetrating voltage of the ion TOF
electrodes. A third electrode, named the “corrector”, has been optimised to
further compensate the presence of the ion TOF with a voltage of 4.8 kV.
CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS 125
(a)
(b)(c)
(d)
1 cm
Figure 4.17: A summary of the expected performance of the electron VMI andion TOF diagnostic. On the left is a 3-D rendering of the electrodes simulated inSimion. The top plot provides a section of the electrodes and their voltages. Inthe middle raw is the simulated calibration of the pixel-to-energy curve. Note theerror bars in the simulated points showing the expected resolution. The plot at thebottom shows the resolution of the ion TOF for fragments with different masses.
In figure 4.17(c) I present the simulated calibration curve corresponding
to equation (4.1) together with the image 4.17(b) used to obtain the peaks
positions. The blue dots represent the peak position obtained from the inverted
images. Each distribution consists of 5·105 mono-energetic particles with a
3-D Gaussian spatial distribution ([σx, σy, σz] = [1000, 5, 5]μm to simulate an
elongated interaction region. The angular distribution in these simulations was
uniform (β2 = 0). The error bars in the plot represent the expected resolution
at the given voltages, optimised for high energy photoelectrons. At 85 eV the
resolution is 0.5% (Δpix/pix) and the pixel size limit is almost reached with a
126 CHAPTER 4. NEW METHODS FOR ATTOSECOND PUMP-PROBE EXPERIMENTS
FWHM of the radial distribution of just 2.2 pixels. This means that a mono-
energetic distributions of electrons will be mapped to a radial distribution with
a peak width comparable to the pixel size of the camera recording the image,
and therefore no further optimisation of the VMI electrodes can improve the
energy resolution of the device. At low energies the resolution is lower, but
still satisfactory with a resolution at 5 eV of 6.2% and a FWHM of the radial
distribution of 6.2 pixels. These are promising simulations as the voltages can
be rescaled to optimise the resolution in the energy range required for the
specific experiment.
In figure 4.17(d) I present the performance of the ion time-of-flight. It can
be seen that the simulated fragments peaks start to merge when considering a
difference of 1 atomic mass out of 80. This is again satisfactory as it allows us
to discriminate heavy fragments of molecular targets with different hydrogen
amounts.
The electron VMI and ion TOF setup has been successfully installed in our
beamline and figure 4.18 shows some benchmark results. In figure 4.18(a) the
ATI rings generated in Xe can be seen in the recorded VMI picture, while in
4.18(b) the different isotopes of Xe have been distinguished in the recorded ion
TOF spectra. Data courtesy of D. Walke and Dr. T. Barillot.
(a)
0
5
10
15
20
Mass (a.u.)128 130 132 134 136
coun
ts
101
102
103
104
129Xe 131Xe132Xe 134Xe 136Xe(b)
Figure 4.18: Benchmark measurements for the electron VMI (a) and for the ionTOF (b). In (a) the ATI rings generated in Xe are visible. In (b) the differentisotopes of Xe have been distinguished.
127
Chapter 5
Attosecond streaking of XUV
and VUV pulses
This chapter is dedicated to the main result of my PhD, the streaking experi-
ments performed to characterise the pulses corresponding to the spectra shown
in figure 3.22 generated with the in-series gas target setup. In the case of the
XUV pulse, the main result is that the effect of the second gas jet on the XUV
pulse is negligible and we confirmed a pulse duration similar to the one already
measured in previous experimental campaigns [84].
Streaking experiments in the VUV range have been rare [21], and never with
pulses obtained with the amplitude gating technique. The results I am going
to present show that attosecond streaking can be successfully implemented in
this spectral range and, similarly to the XUV case, the second gas target does
not affect the pulse duration of the VUV pulse significantly.
The characterisation experiments were performed in the three configura-
tions already presented in 3.22: XUV only, VUV only and XUV and VUV
generated at the same time. In this way we characterised the effect of each
gas target on the temporal profile of each pulse. First I will provide the the-
oretical background of attosecond streaking and then I will present a series of
measurements obtained with an electron time-of-flight spectrometer, together
with their analysis with the least squares generic projection algorithm (LS-
128 CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES
GPA) [139] applied the FROG-CRAB measurements performed [124].
5.1 Theoretical background
Attosecond streaking is, so far, the only technique that allows the full char-
acterisation of an attosecond pulse. The first step of this technique is pho-
toionisation, where a photoelectron wavepacket is produced by the attosecond
pulse. Assuming only one electron participates to the ionisation event, the
transition amplitude a(v) between the initial ground state to the final state
with momentum |v〉, can be written as [140]:
a(v) = −i∫ ∞
−∞dvEUV (t)e
i(W+Ip)tdt, (5.1)
where W is the energy of the final state, EUV (t) is the attosecond electric
field, Ip is the ionisation potential of the target atom, and dv is the dipole
transition matrix element between the ground state and the final state. It can
be seen that, if dv does not include energy dependent factors, either in phase
or amplitude, then a(v) corresponds to the Fourier transform of the incident
pulse EUV (t).
If now an intense NIR field is added to the ionisation process, the transition
amplitude can be rewritten as a function of the delay τ between the two pulses
[124]:
a(v, τ) = −i∫ ∞
−∞eiφ(t)dp(t)EUV (t− τ)ei(W+Ip)tdt (5.2)
The new term with respect to equation (5.1) is the phase term eiφ(t) with:
φ(t) = −∫ +∞
t
v ·A(t′) +A2(t′)
2dt′, (5.3)
where A(t) is the vector potential of the applied NIR field. Note that the
presence of the scalar product v · A(t) implies that the streaking effects are
different for different angles between the momentum of the emitted photoelec-
CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES 129
tron and the streaking electric field. Moreover, the momentum p(t) takes into
account the streaking action with p(t) = A(t) + v.
In figure 5.1 I show the two most relevant streaking regimes for the exper-
iments that will be presented in the next sections. In 5.1(a) I show the case
where the attosecond pulse is much shorter than the gate modulation. This is
the case when streaking the photoelectron spectrum from our XUV attosecond
pulse with a NIR pulse. The gate can be approximated by the portion of the
NIR vector potential overlapping with the short XUV pulse, and therefore can
be considered at any time either as linear or as quadratic with respect time.
The effect of a linear phase is a shift in the Fourier conjugate domain (the
same as GD and the corresponding delay shift in the time domain). Similarly,
the effect of a quadratic phase is broadening or compression of the signal dis-
tribution in the Fourier conjugate domain. These are the main features of an
XUV-NIR streaking trace.
In the case of a phase gate with modulations across the duration of the
UV pulse, sidebands arise, as can be seen in 5.1(b). This is the regime of our
VUV-NIR streaking measurements. Note that measuring the photoelectron
spectrum corresponds to measuring the intensity spectrogram of the photo-
electron wavepacket since I(�ω, τ) = |a(v, τ)|2.
Recalling what was introduced in section 2.2, it can be seen that equa-
tion (5.2), describing a streaking measurement, has the same form as equation
(2.30), describing a FROG measurement, interpreting the effect of the added
NIR field a phase gate on the photoelectron temporal profile. From this obser-
vation a streaking trace can be interpreted as a FROG trace and the pulse and
gate information can be retrieved [124]. In the next section I will discuss the
two main retrieval algorithms that can be used to extract from the measured
I(�ω, τ) the corresponding phase and amplitude of the attosecond pulse and
of the gate.
130 CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES
(a)
-5 0 5
Ene
rgy
(eV
)
85
90
95
Delay (fs)-5 0 5
Am
plitu
de (a
rb. u
.)
-1
-0.5
0
0.5
1(c)
(b)
-5 0 5
Ene
rgy
(eV
)
85
90
95
Delay (fs)-5 0 5
Am
plitu
de (a
rb. u
.)
-1
-0.5
0
0.5
1(d)
Figure 5.1: Theoretical streaking traces (a) and (b) with their respective pulses(c) and (d) showing the case where the UV pulse (dashed blue line) is much shorterthan the wavelength of the streaking pulse (red solid line) in the left column. In theright column the case where the two durations are comparable.
5.1.1 Retrieval algorithms for streaking experiments
The concept behind using an iterative algorithm to retrieve the pulses produc-
ing a given streaking trace is illustrated in figure 2.18. The idea is to apply two
independent constraints, in our case the measured I(�ω, τ) in the frequency
domain and equation (5.2) in the time domain, to predict a pulse (P) and
gate (G) pair that minimises, iteration after iteration, the estimated error of
the retrieval. Applying these two constraints in different domains is defined
as generalised projection and will be the approach shared between the two
presented algorithms. One is the Principal Component Generalised Projection
Algorithm (PCGPA) [139] the second one is the Least-Squares Generalised
Projection Algorithm (LSGPA) [55]. The algorithms are described schemati-
cally in figure 5.2, adapted from [139].
The two algorithms differ in the way they predict the next iteration P and
G. Despite this difference the flow of actions is the same in both cases. First,
CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES 131
Pj, GiOj,i=Pj Gi
O=>S
S'=>O'
Sj,i=PjGj+L(i-1)
S=FFT(S)S'=IFFT(S')
S'= exp[i arg(S)]
time domain constraint
frequency domain constraint
powe
r met
hod
least-squaresm
ethod
LSGPAPCGPA
Figure 5.2: Retrieval algorithms, in blue are the LSGPA steps, in green the PCGPAones. Adapted from [139], with kind permission of Springer Science+Buisness Media.
from the current best guess of P and G the signal matrix S(t, τ) in the time
domain is produced according to (5.2). The trace obtained is then converted
via Fourier transform to the signal trace in the frequency domain S(ω, τ). This
allows the phase information of S(ω, τ), that is not present in the measurement
of I(ω, τ), to be obtained. At this point it is possible to apply the intensity
constraint. The phase obtained from the calculation in the time domain is used
together with the amplitude information measured in the frequency domain
resulting in a signal matrix S ′(ω, τ) =√I(ω, τ) exp
{i · arg
[S(ω, τ)
]}. From
this matrix it is possible then to extract a better estimate of P and G for
the next iteration. For more details about the implementation of the two
algorithms see appendix A.
I will now present an example of performance of the two algorithms. The
numerical implementation of the PCGPA was carried out by Dr. T. Witting,
while I implemented the LSGPA. To test the algorithms I opted for a chal-
132 CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES
lenging streaking trace, of two pulses, at slightly different photon energy (81
eV and 90 eV), and delayed by 3 fs. The results of the comparison for the two
algorithms is shown in figure 5.3.
It can be seen how, in presence of double pulses and isolated spectral fea-
tures the PCGPA fails while the LSGPA is still able to retrieve the correct
pulse structure as expected [139]. This is a simple example to show why the
LSGPA has been chosen over the PCGPA for the retrieval of the VUV pulses.
CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES 133
input(a)
Delay (fs)-10 0 10
Ene
rgy
(eV
)
70
80
90
100
110
LSGPA(c)
Delay (fs)-10 0 10
Ene
rgy
(eV
)
70
80
90
100
110
PCGPA(e)
Delay (fs)-10 0 10
Ene
rgy
(eV
)
70
80
90
100
110
iteration200 400
FRO
G e
rror
0.05
0.1
0.15
0.2(b) LSGPA
PCGPA
Time (fs)-2 0 2
Inte
nsity
(arb
. u.)
0
0.2
0.4
0.6
0.8
1(d) LSGPA
input
Time (fs)-2 0 2
Inte
nsity
(arb
. u.)
0
0.5
1(f) PCGPA
input
Figure 5.3: Retrieval algorithms comparison, in blue are the LSGPA results, inred dashed the PCGPA ones. In (a) the input trace is represented. The reitrevedones are shown in (c) for the LSGPA, and in (e) for the PCGPA. The FROG errorof the two algorithms is shown in (b). The retrieved Temporal profiles are shown in(d) and (f).
134 CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES
5.2 XUV and VUV streaking experiment
5.2.1 Experimental setup
Figure 5.4 shows the TOF chamber, dedicated to the streaking experiments.
TOF
2-part mirror
filters
TOF
2-part mirror
filters
Figure 5.4: TOF chamber, picture on the left, schematics on the right. Theelectron time-of-flight spectrometer is visible on the right portion of the chamber,with the nozzle encasing the electrostatic lens. The 2-part mirror assembly focusesthe incoming beam in front of the nozzle aperture. A set of filters (green box)spectrally select a portion of the harmonic emission. The NIR beam is directedoutside the chamber through a lens for the re-imaging the focus on a CCD cameraoutside the chamber.
Not visible in figure 5.4 is the effusive needle used to deliver the gas target
in the interaction region in front of the TOF nozzle. It was mounted on a x-y-z
manipulator on the lid of the chamber so that the optimum alignment could
be chosen looking at the signal count rate. The filters (shown in the green
box in figure 5.4)are used to spectrally filter the HHG emission to obtain an
isolated attosecond pulse.
The 2-part mirror assembly consists of a multilayer focusing mirror (f =
10.5 cm) with the inner part (4 mm diameter) cut out and mounted on a
piezo-stage allowing a spatial offset between the two parts of the mirror to be
introduced that corresponds to a delay between pulses reflected off the two
different portions of the multilayer mirror. The tip-tilt screws of the mirror
CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES 135
mount were equipped with motorised actuators for spatial alignment of the
outer part of the mirror with respect to the inner, as shown in figure 5.5.
inner part
outer part
tip-tilt adjustment5mm
Figure 5.5: Two part mirror assembly, with the detail for the inner part cut outfrom the outer one. The inner part is mounted on a piezo stage providing a delayrange of 80 fs with a resolution of 0.3 as.
The electron time-of-flight spectrometer consists of a nozzle, that houses
an electrostatic lens, and a field-free drift-tube at the end of which the photo-
electrons are detected with an MCP.
In the following paragraphs I will describe more thoroughly the steps per-
formed to record and calibrate the streaking traces for the characterisation of
the XUV and VUV pulses.
Spectral filtering
The beam (harmonics +NIR) goes through an iris that allowed us to aperture
the NIR to reach the desired intensity (in the range of 1012 Wcm−2) at the in-
teraction region in front of the TOF aperture. So far the harmonic emission has
not undergone any manipulation, therefore, to obtain an isolated attosecond
136 CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES
pulse, as explained in 3.3, a portion of the HHG spectrum has to be selected.
The beam can go through a set of filters (green box in figure 5.4, shown out
of the beam path). The filters were mounted side by side on holes with 3 mm
aperture and 1 mm separation, as shown in figure 5.7. The foils used were
Kapton (7.5 μm thick) for the selection of the NIR pulse only, zirconium (200
nm thick) for the selection of the cut-off region of the harmonics, and indium
or tin (200 nm thick) for the selection of the VUV harmonics. The selected
pulses were then directed to the 2-part mirror assembly, where the inner part
of a focusing multilayer mirror (Mo:Si, selecting ≈8 eV bandwidth at 90 eV)
was translated on a piezo stage (P-753, PI GmbH, 80 fs delay range, 0.3 as
resolution) in order to provide a delay manipulation between the beam on the
inner part of the mirror, with respect the beam on the outer part.
Energy (eV)10 20 30 40 50 60 70 80 90 100
Tran
smis
sion
(%)
0
10
20
30
40
50
60
H9
H11
H13
H15
MoSiZrSnIn
Figure 5.6: Filters for the spectral selection of different portions of the HHGspectrum. The laser central wavelength is λ0 = 765 nm.
CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES 137
The spectral properties of the metallic filters and of the multilayer mirror
are shown in figure 5.6. It can be that the Mo:Si and Zr filter combined provide
a spectral bandpass of 8 eV centred at 90 eV. The Sn filter bandpass contains
2 harmonics (11th and 13th) while the In filter bandpass contains only one
harmonic (9th). While it is difficult to precisely define the central wavelength
of a few cycle pulse, we use λ0 = 765 nm, according to the position of the
main peak of the fibre spectrum shown in figure 3.10. Assuming a central
wavelength closer to 800 nm would imply the presence of three harmonics
under the transmission window of Sn. The photoelectron spectra measured
detected only two of peaks, confirming a central wavelength between 760-780
nm.
Spatial and temporal overlap
Figure 5.7 shows how different pulse combinations can be delivered to the inter-
action region. The first two combinations (XUV-NIR, VUV-NIR) were used to
perform the characterisation of the attosecond pulses. The last combination
(XUV-VUV) will enable us to perform future attosecond-pump attosecond-
probe experiments.
XUV-NIR VUV-NIR XUV-VUV
Figure 5.7: Schemes to combine different pulse pairs in the TOF chamber. On theleft a picture of an actual filter assembly.
Once the main geometrical alignment is obtained according to figure 5.7,
it is necessary to verify the spatial and temporal overlap of the two pulses at
the interaction region. To do so, an imaging system was designed to re-image
138 CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES
the focus inside the chamber onto a CCD camera (see the mirror and the
lens after the focus in figure 5.4). Spatial overlap was achieved with motorised
actuators on a tip-tilt mount holding the outer part of the 2-part mirror. Once
the spatial overlap is satisfactory, the focal image is recorded as a function of
delay between the inner and outer part of the multilayer mirror. In this way
it is possible to record the spatial interference pattern occurring between two
delayed replicas of the NIR pulse (no filters used in this case). Figure 5.8 ,
shows the results of such a measurement.
Delay (fs)45 50 55 60 65 70 75 80
Inte
nsity
(arb
. u.)
104
1
2
3
4
5(a)
(b) (c)
Figure 5.8: Measurement to temporally overlap the inner and outer components ofthe 2-part mirror. The interference pattern is measured to find the temporal overlapand the spatial overlap is optimise to maximise the fringes contrast.
Note that the zero delay t0, found with this method is not the t0 for the
pulses going through the filter assembly, since in that case there will be delays
due to propagation in the filters relative to vacuum (1-2 fs through the metallic
filters, 50 fs through Kapton). However the piezo stage has enough delay range
(80 fs) to compensate for these.
CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES 139
Electron time-of-flight spectrometer calibration
The design of the electron time-of-flight spectrometer (now replaced by the
electron VMI and ion TOF) used to record the streaking traces, is similar
to the one presented in [141]. The photoelectrons are detected by an MCP
producing a hit signal with an amplitude of ≈10 mV and a time duration of ≈3
ns. The signal from the MCP is amplified with a x10 fast amplifier (TA1800B,
Fast Comtec GmbH, 1.8 GHz bandwidth) and acquired on a computer by
a time to digital converter (P7889, FAST Comtec GmbH, 0.1 ns time bin).
The TOF nozzle, equipped with an electrostatic lens (set of 4 electrodes), is
positioned 2 cm from the interaction region and has an aperture of 4 mm. This
allows for a high angular resolution at the expense of the collection efficiency
(0.05 % assuming uniform 4π emission and including inner TOF geometry).
The low collection efficiency was not a problem for the XUV measurements,
but the electrostatic lens was required for the VUV measurements to boost
the collection efficiency and therefore reduce the data acquisition time. The
lower count rate in the VUV case is due mainly to the poor reflectivity of
the Mo:Si mirror in this spectral region, estimated to be as low as 0.2% (see
paragraph describing the VUV photon flux measurement). Figure 5.9 shows
the schematics of the electrodes.
For the lens-free case, the calibration is straightforward, as the TOF length
was already carefully measured [79]. The measurement of t0 for the time-of-
flight axis was performed by looking at the photon peak obtained with the
NIR pulse (scattered photoelectron directly hitting the MCP), and the time
to energy conversion followed the simple formula:
E =1
2me
(L
TOF
)2
, (5.4)
where me is the electron mass, L is the spectrometer length, and TOF is the
time-of-flight measured. The presence of an electrostatic lens makes equation
(5.4) not valid, since the path from the interaction region to the detector is
140 CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES
V2=0.90 VsetV3=0.96 Vset
V1=0.8 Vset
V4=Vset
V5=Ground
20 mm
Figure 5.9: TOF lens electrodes schematics. A potential divider applied differentvoltages to different electrodes.
not field free. For the calibration of the electrostatic lens I used three ap-
proaches. First the calibration was performed experimentally, looking at the
shift of ATI peaks in Ar and of the main peak of the selected VUV harmonics.
Then I solved the equation of motions of electrons with different initial veloc-
ities, assuming the lens behaves as a capacitor, with an effective voltage Veff
applied, accelerating the electrons. And finally I performed simulations with
Simion, including the full geometry of the nozzle. The results of the calibration
experiments and simulations are shown in figure 5.10.
The experimental points were taken looking at the shift of ATI peaks op-
erating the TOF with the lens on and off. I also included the shift of the
strongest harmonic from the VUV spectra, recorded in the same way. The
collection enhancement factor is obtained with Simion simulations, from a
uniform 4π emission distribution. The effective voltage Veff to use in the sim-
ple model to fit the experimental and simulated points is Veff = 10.46 V. The
analytical function, not requiring any interpolation, was used to calibrate the
recorded streaking traces.
CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES 141
distance (mm)320 340 360 380 400 420di
stan
ce (m
m)
20
40Simion Simulation
(a)
Veff
Simple Model(b)
energy measured WITH lens (eV)0 10 20 30 40 50ac
tual
ene
rgy
(no
lens
) (eV
)
0
10
20
30
40(c)
Energy (eV)0 5 10 15 20 25 30 35C
olle
tion
enha
ncm
ent f
acto
r
1
2
3
4
5(d)Simulated
Smoothed
Figure 5.10: TOF calibration. The electrodes geometry is showed as a section in(a). The schematics of the simple model for the analytical effect of the electrostaticlens is shown in (b), with the electrostatic lens simplified to an ideal capacitor.The experimental and simulated results are presented in (c) with the relationshipbetween the energy measured with the lens on, and off. Finally the ratio betweenthe number of electrons collected with the lens on and with the lens off is shown in(d). An enhancement factor up to 3 is expected.
142 CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES
5.3 Results
5.3.1 XUV Results
With a few cycle pulse, a main attosecond pulse is produced, corresponding
to the main peak of the carrier. The lower following peaks of the carrier
generate satellite pulses. When the XUV wavepackets are streaked by the
same generating NIR pulse, they are shifted in opposite directions, as they are
produced half a cycle apart. The main and the secondary attosecond pulses
are therefore streaked to the highest energy values, in turn, every π shift of
the CEP. To optimise the XUV pulse contrast, I recorded some photoelectron
spectra without any filter and with the iris almost closed, to allow only the
inner part of the mirror to be illuminated. In this way the XUV pulse and the
generating NIR pulse reach the interaction region with the best spatial and
temporal overlap possible. It is then possible to record photoelectron spectra
as a function of the CEP. From the recorded spectra, the best CEP value for
the generation of a isolated attosecond pulse can be selected [79, 142]. The
results of these measurements, obtained in Ne, are shown in 5.11.
The first peak at high energies (105 eV) corresponds to the streaked wavepacket
of the main attosecond pulse. The same peak is then streaked to low energies
(75 eV) for a CEP shift of π. Following the analysis suggested in [79] a max-
imum contrast of Coff = 6.0 ± 0.9 has been measured in the VUV off case,
and a maximum contrast of Con = 6.9 ± 0.7 in the case of the VUV on case,
as shown in figure 5.11(d).
From this dataset it is also possible to measure the CEP offset between the
case with the VUV on and off, as shown in figure 5.11(c). The measured offset
is 0.15±0.07π corresponding to the average of the two shifts obtained from the
two measured peaks. This value is consistent, within the experimental errors,
with the 0.23±0.06π value extracted from the data obtained from the flat field
spectrometer in figure 3.23 confirming that the second gas jet has little effect
on the XUV pulse generation.
CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES 143
VUV on
(a)0 0.5 1 1.5 2 2.5 3 3.5 4E
nerg
y (e
V)
80
100
120
VUV off
(b)0 0.5 1 1.5 2 2.5 3 3.5 4E
nerg
y (e
V)
80
100
120
CEP ( )0 0.5 1 1.5 2 2.5 3 3.5 4C
ount
s (n
orm
.)
00.5
1
CEP offset=0.15 0.07(c)
VUV onVUV off
CEP ( )0 0.5 1 1.5 2 2.5 3 3.5 4
Con
trast
0
5(d)
VUV onVUV off
Figure 5.11: XUV photoelectron spectra recorded as a function of CEP to optimisethe NIR pulse CEP to obtain an isolated XUV pulse with the best contrast possible.(a) corresponds to the case where both the Kr and Ne jet were on. (b) correspondsto the XUV only case. In (c) the integrated signal (within the black dashed lines)in the two above cases is shown for direct comparison. In (d) the contrast of theattosecond pulse is shown as a function of CEP.
To fully quantify this effect, complete XUV-NIR streaking traces were
recorded with the VUV on and off. Photoelectrons ionised from the 2p level
of the Ne gas target provide the photoelectron wavepacket replica of the XUV
pulse that is then streaked by the few cycle NIR pulse. The NIR intensity is
adjusted with the iris in the TOF chamber to obtain a streaking amplitude of
a few eV, corresponding to an intensity of INIR ≈ 1012 Wcm−2. An integration
time at each delay step of 10 s was used (150 delay steps, 0.1 fs step size) with
an integrated peak height of 80 counts at 90 eV. The recorded raw traces, and
the smoothed ones are shown in figure 5.12.
144 CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES
(a)
Delay (fs)-5 0 5P
hoto
n en
ergy
(eV
)
70
80
90
100
110(b)
Delay (fs)-5 0 5 P
hoto
n en
ergy
(eV
)
70
80
90
100
110
(c)
Delay (fs)-5 0 5P
hoto
n en
ergy
(eV
)
70
80
90
100
110(d)
Delay (fs)-5 0 5 P
hoto
n en
ergy
(eV
)
70
80
90
100
110
Figure 5.12: XUV-NIR raw (left) and smoothed (right) streaking traces. (a)-(b)correspond to the case of the Kr jet off, while (c)-(d) correspond to the case of theKr jet on.
The smoothing procedure consists in isolating the signal coming from the
Ne 2p level. First, the signal below 70 eV, corresponding to ATI photoelectrons
and photoelectrons ionised from other levels is removed. After applying a
threshold corresponding to 2% of the maximum signal, the center of mass
and the second moment of the spectrum at each delay is computed and used
to select the streaking trace with a spectral Gaussian window with position
set by the first moment and a width proportional to the second moment of
the spectrum recorded at each delay (minimum filter width of 12.4 eV in the
non-streaked region of the trace is larger than the wavepacket bandwidth to
ensure no clipping). The first moment E(τ), or Center Of Mass (COM), of the
recorded spectrum as a function of delay provides a measurement of the vector
potential A(τ) [127] through the relationship:
A(τ) =
√me
2E0ΔE(τ)e cos θ
. (5.5)
Here E0 is the COM of the recorded spectrum in absence of the NIR vector
potential (i.e. at early/late delays) that is taken as a reference to compute
the shift ΔE(τ) as a function of delay. The photoelectron collection angle θ
is small in this setup (≈ 5◦) and therefore cos θ ≈ 1. The CEP shift of the
CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES 145
NIR pulse between the two experimental configuration can be measured from
A(τ). In figure 5.13 are shown the two NIR pulses retrieved from the smoothed
traces.
(a)
VUV OFFPho
ton
ener
gy (e
V)
70
80
90
100
110RawFiltered
(b)
VUV ONPho
ton
ener
gy (e
V)
70
80
90
100
110
Time (fs)-4 -2 0 2 4 6 8
Am
plitu
de (a
rb. u
.)
-1
-0.5
0
0.5
1
CEP shift =0.28 0.07
(c) VUV OFFVUV ON
Figure 5.13: NIR pulse extraction from streaking traces. (a) and (b) are again thestreaking traces in the two cases of the Kr jet off and on. In (c) are plotted the twovector potentials extracted from the COM of the streaking traces.
A Fourier filter has been applied to the raw COM obtained. Only the
portion within the 450-1100 nm spectral range has been selected. The pulse
durations obtained are 3.5±0.1 fs in both cases. The uncertainty is due to the
small temporal widow over which the NIR pulses are sampled. The raw data
provides only ten points in the spectral window of interest, making it difficult
to select an appropriate central wavelength for the expression of the CEP
shift. For this reason, smoothing and oversampling are required. Moreover
the CEP fluctuations of the system impacts directly on the sharpness of the
trace. While fluctuations should not change the overall NIR pulse duration,
they blur the trace. For example, a 200 mrad RMS fluctuation on the CEP
146 CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES
corresponds to a jitter of 0.08 fs of the carrier. Selecting the maximum of the
oversampled spectrum as the central wavelength, the measured CEP shift is
0.28±0.07π. Given that there is no statistical option to compute the error from
multiple measurements, I attributed to this measurement the error obtained
from CEP scan recorded in the TOF chamber shown in figure 5.11. In fact
both measurements rely on the same parts of the experimental apparatus,
and on the same physical process. However, I expect the error to be bigger
in the streaking trace method due to the smoothing procedures, and related
uncertainties, required to evaluate the CEP. For this reason, even if the CEP
shift obtained in this case is bigger than the two previous estimates, I consider
it still in reasonable agreement with the previous values and once again small
enough not to disrupt the production of the XUV pulse.
To mitigate the short delay range of the experimental data, a few fem-
toseconds of unstreaked spectra have been added to the trace at early and late
delays, in order to provide the algorithm with more points to converge to a
stable spectral solution and the spectrum integral at each delay has been nor-
malised to unity. In figure 5.14 the results of the LSGPA algorithm analysis
on both traces, with the VUV on and off, are shown.
The input matrix for the algorithm has 512×401 elements (energy × de-
lays). The algorithm converged to a stable solution in 500 iterations, reaching
a FROG error of 5% in the case with the VUV off, and a FROG error of 6%
with the VUV on. The two retrieved pulse durations are of 271±25 as and
257±21 as. The error has been computed as the standard deviation of the
distribution of the XUV pulses obtained from the final iteration signal matrix
according to equation (A.12). The pulse durations in the two experimental
configurations are therefore comparable, confirming that the presence of the
Kr gas jet for the production of the VUV pulse does not perturb the generation
of the XUV attosecond pulse.
CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES 147
VUV OFF(a)
Ene
rgy
(eV
)
80
90
100
110VUV ON
(b) Energy (eV
)
80
90
100
110
(c)
Ene
rgy
(eV
)
80
90
100
110 (d) Energy (eV
)
80
90
100
110
Time (fs)-5 0 5
Inte
nsity
(arb
. u.)
0
0.5
1
271 25as
(e)
Time (fs)-5 0 5
Intensity (arb. u.)
0
0.5
1
257 21 as
(f)
Energy (eV)80 90 100 110
Inte
nsity
(arb
. u.)
0
0.5
1
Pha
se (
)
-1
0
1(g)
Energy (eV)80 90 100 110
Intensity (arb. u.)
0
0.5
1(h)
-1
0
1
Figure 5.14: XUV pulse retrievals in the case of having the VUV pulse off (leftcolumn) and on (right column). The top row shows the input traces for the LSGPAanalysis, the second row shows the retrieved trace. The third row shows the retrievedpulses in the time domain, and the last row in the spectral domain.
148 CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES
5.3.2 VUV Results
For attosecond streaking in the VUV energy range, the target gas choice is
limited by the low photon energy. For example, when filtering the VUV pulse
with indium the available photon energy is peaked at 15 eV, close to the Ip
of Xe (12.1 eV from level 5p3/2, 13.4 eV from level 5p1/2) [143] and Kr (14.1
eV from level 4p). The proximity to the Ip of these atoms, and the presence
of features in the electronic structure (such as the spin orbit splitting of Xe)
may also affect the streaking measurement, since the dipole transition matrix
elements dv at these energies are not well known, and they may introduce
some dispersion effects. This calls into question the assumption that the pho-
toelectron wavepacket perfectly replicates the incoming photon wavepacket.
The role of the ionisation step has been of interest in attosecond physics, for
example in relation to the time delay between the ionisation of different en-
ergy levels [7, 144]. Such distortion effects, if limited to a time delay, do not
prevent the temporal characterisation of a pulse via attosecond streaking. The
open question is whether there is a further effect, introducing a significant
reshaping of the photoelectron wavepacket with respect to the incident pulse.
From an experimental point of view, it is difficult to address this question, as
it would require the measurement of the same pulse with different gas targets.
This task is particularly challenging in the low energy range where no mea-
surements have been performed. Palatchi et al. [145] presented experimental
measurements of these delays as a function of harmonic order for He Ne Ar
and Kr. The low energy range 1-3 eV (above Ip), which would be of specific
interest for this work, is not covered experimentally nor theoretically.
While all these aspects should be taken into account, it is important to
remember that the spectral range of interest for the VUV pulses measured
in this work is limited to one harmonic (when filtering the harmonics with
indium) or two (when using a tin filter). This implies that the dispersion
effects should be characterised in a relatively narrow range. More comments
on these aspects will be given when discussing each dataset.
CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES 149
Photon Flux Measurement
In collaboration with PhD student Paloma Matia-Hernando we calibrated the
photon flux of the VUV pulses. We used a scintillator based on sodium salicy-
late (common aspirin) that has the property of absorbing light in the UV-VUV
(30-300 nm) and converting the absorbed photons to the 400 nm range with
a nearly constant quantum efficiency [146–149]. The calibration procedure in-
volves producing a 266 nm signal with a 3ω setup (Eksma optics kit) from
the output of the CPA laser system. At this wavelength we used a NIST
calibrated and PTB traceable photodiode powermeter (Thorlabs S120VC) to
determine the pulse energy. With this known source we could then calibrate
a sodium salicylate coated window. The coating was produced by applying
few drops of a 10:1 mass solution of methanol and aspirin on a fused silica
window. To obtain a coating as uniform as possible the fused silica window
was on an even surface and each drop was deposited after the previous one
had dried almost completely. No additional heating was applied to speed up
the drying process. The 400 nm fluorescence signal from the coating was de-
tected with a photon multiplier tube (PMT). Illuminating the window with a
variable amount of 266 nm radiation, that could be measured independently
with the power meter head, allowed us to obtain a voltage to photon-number
calibration. The constant quantum efficiency allows this same calibration to
be used in the VUV range, and thereby convert the PMT voltage measured
when illuminating the coated window with the VUV pulses to a photon flux.
In figure 5.15 the calibration and measurement steps are shown (left) together
with the relevant spectral signals (right)
Particular care was taken in the calibration procedure in order to remove
any stray light. The 266 nm signal was selected with a prism, and the remain-
ing 400nm and 800nm components were rejected with beam blocks well before
the position of the powermeter head. A blue filter selected only the 400nm
component generated by the coating. The sodium salicylate coated window
150 CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES
lambda (nm)200 300 400 500 600 700 800 900
Inte
nsity
(arb
. uni
ts)
0
5
10
15coating signalTHGCPA spectrumPMT response
coating filter
PMT266 nm V
PMTVUV V
mea
sure
men
tca
libra
tion
Figure 5.15: With a known source at 266 nm it is possible to calibrate the sodiumsalicylate coating and then perform the photon flux measurement on the actualVUV signal. On the right the signals obtained from the coating and the 3ω setupare shown.
was mounted on the TOF chamber, and the VUV radiation delivered to it
with an UV enhanced mirror (Thorlabs PF10-03-F01). The reflectivity of the
2-part mirror was estimated by performing two measurements, one with the
2-part mirror in the beam line, and one with only the UV-enhanced mirror.
An estimate of the photon flux was also derived from the count rate mea-
sured in the TOF chamber. Table 5.1, shows the relevant quantities for this
estimate.
Quantity value
Count Rate 5 counts/shot
TOF coll. eff. 0.05%
Events=count rate/TOF coll. eff. 104events/shot
Gas density 5 · 1023 m−3
Volume 315 μm3
Cross section 38 Mb [150]
VUV photons at interaction 1.4 · 104 photons/pulsePulse energy at interaction 0.045 pJ
Table 5.1: Photon flux estimate from count rate
Table 5.2 summarises the results obtained with this method, together with
the photon flux estimated with the sodium salicylate method. The VUV radi-
ation was filtered with tin. No measurement is available in the case of indium
due to the lower signal level.
CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES 151
Quantity PMT estimate Count rate estimate
Phot. flux delivered (photons/pulse) 2 · 104 1.4 · 104Energy delivered (pJ) 0.064 0.045Phot. flux generated (photons/pulse) 1.3 · 108 6.5 · 107Energy generated (pJ) 427 299
Table 5.2: Results of the photon flux measurement comparing the sodiumsalicylate and PMT method with the estimate from the count-rate from theTOF spectrometer.
The reflectivity of the 2-part mirror in the VUV was found to be 0.2% and
together with the small aperture of the TOF spectrometer are the main reasons
for the low level signal obtained in the streaking traces that will be presented.
This is understandable as our Mo:Si multilayer mirror is optimised for the
XUV range (≈ 90 eV). Changing the 2-part mirror coating is a straightforward
way to improve the number of photons delivered to the interaction region, for
example a gold coated mirror has a reflectivity up to 15% in the VUV range
[151].
Indium filtered pulse
Selecting the 9th harmonic with a photon energy of ≈ 15 eV, the only options
for rare gas targets for streaking are Xe (12.1 eV from level 5p3/2, 13.4 eV
from level 5p1/2)[143] and Kr (14.1 eV). I opted to use Xe to make sure all the
available bandwidth of the generated pulse was able to ionise the target atom.
From a theoretical point of view, the generation of a short pulse using In as
a spectral filter had already been confirmed by the theoretical work of our
collaborator J. Henkel et al. [31]. The two most interesting results obtained
from the TDSE simulations performed can be summarised as follow. First,
the pulse duration can be sub-femtosecond, but the temporal structure can be
quite modulated, depending on the CEP of the generating field. For this reason
we will refer to the pulse duration both using the standard FWHM definition,
and also with the second moment of the temporal intensity distribution that
152 CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES
takes into account the contributions present in the low pedestal of the pulse.
The second interesting point of this theoretical work was the study of the
polarisation state of the pulse. While a pulse in the cut-off region of the
generated high harmonics is inherently limited to a single emission, a pulse
selected in the low energy range can have contributions from the different
half-cycles of the generating pulse. As already introduced in section 3.3, it
is possible to implement polarisation gating to isolate the harmonic emission
even for a many cycle pulse. With this idea in mind, the simulations performed
considered the effect of polarisation gating in the generation of the VUV pulse.
The main advantage of this scheme is the production of a more stable and
less structured VUV pulse, in the sense that sub-femtosecond durations is
achieved for a wider CEP range and with a less modulated structure. However,
the results showed that the NIR pulse time-dependent polarisation state is
partially imprinted in the generated VUV pulse, while the pulse duration is
not significantly shortened.
For these reasons, polarisation gating has not been adopted to shorten the
pulse, as it would have a minimal effect on the overall pulse duration, at the
price of complicating the experimental setup. Our beamline, in fact, is opti-
mised for the collinear propagation of the streaking field and of the attosecond
pulse. Implementing the polarisation technique would require the delivery of a
linearly polarised pulse to the experimental chamber from a different path with
respect the generating NIR field. Moreover, a VUV pulse with a polarisation
state not well defined is not the ideal candidate for pump-probe experiments
due to the difficulties in modelling such pulse while interacting with the system
under investigation.
In figure 5.16 are presented the raw and smoothed traces obtained by ion-
ising a Xe gas target with the In filtered harmonics generated in Kr. The
spectrum at each delay (86 delay steps, 0.2 fs step size) was integrated for 45
seconds to reach a peak height of 15 counts for the unstreaked portion of the
spectrum.
CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES 153
(a)
Delay (fs)-5 0 5
Pho
ton
ener
gy (e
V)
11
12
13
14
15
16
17
18
19(b)
Delay (fs)-5 0 5
Pho
ton
ener
gy (e
V)
11
12
13
14
15
16
17
18
19
Figure 5.16: Raw(left) and smoothed (right) streaking traces obtained in Xe fil-tering the VUV radiation with indium.
The smoothing procedure was similar to the one introduced for the XUV
traces. In this case the threshold level was increased to 12% of the maximum
signal, given the lower statistics. One technical difficulty was the application
of the Jacobian in the conversion from the TOF axis to energy axis due to
the proximity of the signal to zero (see the Ip level of Xe in figure 5.16 that
corresponds to the zero energy of the measured photoelectrons). The Jacobian
can be computed from equation (5.4) to be:
d(TOF )
dE=
√meL2
8E3, (5.6)
which goes to infinity when the energy goes to zero. This means that this factor
would amplify all signal around zero (saturated region in the raw data of figure
5.16), where most of the noise is condensed. All electrons with a time-of-flight
longer than 2 μs correspond to an energy below 0.1 eV. Considering that there
is a start signal (laser shot) every 1 ms, it is clear that slow electrons are
heavily affected by any random noise collected for high time-of-flight. For this
reason, the collection of signal was interrupted after 2 μs (notice how the raw
signal does not reach the Ip level in figure 5.16), and a super Gaussian filter of
154 CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES
order 16 was used to cancel the signal in the very close proximity to the origin
(< 0.5 eV), without altering the structure of the streaking trace. Applying
the 12% threshold cancels the small signal of a secondary sideband appearing
at 17.5 eV. This modification was found not to disrupt the LSGPA analysis.
In fact, the presence of secondary sidebands is related to the higher intensity
of the streaking NIR field and they mostly provide an information about the
intensity of the NIR field rather than about the VUV pulse structure. The
results of the LSGPA analysis are shown in figure 5.17
12 14 16 18
Pha
se (r
ad)
0
0.5
1
1.5
Delay (fs)-5 0 5P
hoto
n en
ergy
(eV
)
12
14
16
18
Delay (fs)-5 0 5 P
hoto
n en
ergy
(eV
)
12
14
16
18
Time (fs)-5 0 5
Inte
nsity
(arb
. u.)
0
0.5
11.7 0.1 fs
Photon energy (eV)12 14 16 18
Inte
nsity
(arb
. u.)
0
0.5
1
1.5
Figure 5.17: LSGPA analysis of the streaking traces obtained in Xe filtering theVUV radiation with indium. Plots as in 5.14
The input matrix for the algorithm had 1024×160 elements (energy × de-
lays). The algorithm converged to a stable solution in 1000 iterations, reaching
a FROG error of 2%. The pulse duration is 1.7±0.1 fs, and despite being longer
than expected, it is close to the FTL which is 1.66 fs. The discrepancy with
the expected attosecond duration obtained by the TDSE calculations [31] can
be attributed to a number of factors. First of all, the TDSE simulations were
performed in a Ne gas target. In the experiment, I opted for Kr as the gen-
erating medium due to the higher signal levels. However, the lower Ip of Kr
allows the less intense half-cycles of the generating NIR to give more contri-
CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES 155
bution to the HHG yield. For this reason, the pulse temporal profile may be
more modulated than estimated for a Ne target. Moreover, it is possible that
the CEP value was not fully optimised for the shortest pulse VUV duration.
In fact the CEP was always optimised according to the signal generated in
the Ne target in the XUV region, to make sure I could preserve the XUV
attosecond pulse. Finally, the proximity of the photon energy to the Xe Ip and
the presence of the spin-orbit split might introduce some distortion effects in
the photoionisation step of the streaking measurement.
Tin filtered pulse
With a tin filter the 11th and 13th harmonics of the driving laser are selected.
With this photon energy it is possible to ionise Ar and therefore I decided
to use Ar as the streaking gas target to avoid the spin orbit splitting of Xe.
In this case however, to boost the signal, I used the electrostatic lens in the
TOF nozzle. As shown in figure 5.10, I performed both experimental and
simulated calibrations for the performance of the TOF with the electrostatic
lens, from which I could use a simple analytical formula to estimate the shift in
the measured time-of-flight with respect to the field free case. The parameter
found to fit the experimental calibration is Veff = 10.46 V. However, once I
tried to apply this parameter to the actual measured trace, the two harmonics
peaks were not shifted to the “expected” positions, as shown in figure 5.18.
The “expected” positions are given by the presence of only two harmonics
under the transmission window of the tin filter. Applying Veff = 10.46 V
moves the measured harmonics to a spacing corresponding to a laser central
of λ0 = 820 nm. If this was the case, some signal should be present for the
15th harmonic (top solid thin black line), as it would fall within the spectral
transmission window (dashed red line red). Moreover it can be seen that the
signal of the secondary sideband, that should correspond to the 15th harmonic,
does not match the expected position very well. In the left plot of figure 5.18 I
show the same trace calibrated with Veff = 9 V. The agreement is better in this
156 CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES
Delay (fs)-5 0 5
Pho
ton
ener
gy (e
V)
14
16
18
20
22
24
26
28
30
Delay (fs)-5 0 5
Pho
ton
ener
gy (e
V)
14
16
18
20
22
24
26
28
30
Figure 5.18: Calibration of the nozzle effect while recording streaking traces ob-tained in Ar filtering the VUV radiation with tin. On the left the trace is calibratedwith Veff = 9 V, on the right with Veff = 10.46 V. The thin black lines are the har-monics positions according to λ0. The red-dashed line in overlay is the transmissionof tin.
case, with λ0 = 780 nm and the 15th harmonic positioned just at the edge of the
spectral window. The reason for the discrepancy between the calibrated Veff
and the value used to position the trace correctly has not been determined. It
is possible that the grounding conditions of the electrodes between experiment
and calibration (performed a few days apart) may have changed, for example
due to a loose cable. It is important to note, however, that this disagreement
is not detrimental for the LSGPA analysis. In fact the uncertainty on the Veff
parameter corresponds simply to an uncertainty on the central wavelength of
the VUV pulse.
Note how the signal is close to the Ar Ip level. Using the electrostatic
lens improved the signal to noise ratio in the low energy range of the signal.
The corresponding time of flight for a photoelectron with an energy of 0.1
eV is 0.35 μs with the electrostatic lens on, and 2 μs with the lens off. This
means that more random noise can be rejected as the maximum time of flight
can be reduced significantly when the electrostatic lens is on. In fact, the
data presented in figure 5.19 did not require any smoothing procedure at low
CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES 157
energies, as was the case in 5.16.
Two streaking traces for the Sn-filtered VUV pulses are presented, one with
the XUV on (Ne jet on) and one with the XUV off (Ne jet off), to quantify
the effect of the generation of the XUV pulse on the VUV one. In figure 5.19 I
show the measured raw traces and the smoothed traces corresponding to these
two experimental configurations.
(a)
Delay (fs)-5 0 5
Pho
ton
ener
gy (e
V)
15
20
25
30(b)
Delay (fs)-5 0 5
Pho
ton
ener
gy (e
V)
15
20
25
30
(c)
Delay (fs)-5 0 5
Pho
ton
ener
gy (e
V)
15
20
25
30(d)
Delay (fs)-5 0 5
Pho
ton
ener
gy (e
V)
15
20
25
30
Figure 5.19: Raw (left) and smoothed (right) streaking traces obtained in Arfiltering the VUV radiation with tin. (a) and (b) correspond to the case of XUV off,(c) and (d) to the case of XUV on.
Despite using the electrostatic lens the signal level was low. The spectrum
at each delay was integrated for 3 minutes obtaining a signal with a peak
height of 30 counts when the Ne jet was on, and 60 when the Ne jet was off,
confirming the factor 2 drop in signal when operating the two gas targets at the
same time as already seen in figure 3.22. The drop in signal can be explained
as absorption of VUV photons in the Ne target.
The smoothing procedure is similar to the one performed for the previous
traces. A threshold level of 4% (8%) was applied in the case of the XUV off
(on), together with a 2D Fourier filtering, to preserve as much as possible all
the interference structures present between the two harmonics. Non-streaked
spectra were added at the trace edges and the integral of each spectrum was
normalised to unity. In figure 5.20 I present the results of the LSGPA analysis
158 CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES
on the smoothed streaking traces.
XUV OFF(a)
Ene
rgy
(eV
)
15
20
25XUV ON
(b) Energy (eV
)
15
20
25
(c)
Ene
rgy
(eV
)
15
20
25(d) E
nergy (eV)
15
20
25
Time (fs)-10 -5 0 5 10
Inte
nsity
(arb
. u.)
0
0.5
1
585 31as
(e)
Time (fs)-10 -5 0 5 10
Intensity (arb. u.)
0
0.5
1
576 16 as
(f)
Energy (eV)15 20 25
Inte
nsity
(arb
. u.)
0
0.5
1
Pha
se (
)
-1
0
1(g)
Energy (eV)15 20 25
Intensity (arb. u.)
0
0.5
1(h)
-1
0
1
Figure 5.20: LSGPA analysis of the streaking traces obtained in Ar filtering theVUV radiation with tin. The left column corresponds to the case of the XUV off(Ne jet off), while the right, column corresponds to the case of the XUV on (Nejet on). The top row shows the measured traces while the second row shows theretrieved traces. In (e) and (f) the temporal profile of the retrieved pulses is shown(solid blue) together with the theoretical results from TDSE simulations (dashedblack). In (g) and (h) the retrieved spectral amplitude (solid blue) and the spectralphase (solid red) are plotted.
CHAPTER 5. ATTOSECOND STREAKING OF XUV AND VUV PULSES 159
The input matrix for the algorithm has 1024×370 elements (energy × de-
lays). The algorithm converged to a stable solution in 500 iterations, reaching
a FROG error of 2% in the case with the Ne jet off, and a FROG error of
5% with the Ne jet on. The two retrieved pulse durations are of 585±31 as
FWHM (second moment 950±30 as) and 576±16 as FWHM (second moment
860 ± 45 as). From this analysis it is verified that the pulses with the XUV
jet on and off, preserve a comparable pulse duration within the experimental
error. The contrast with respect to the two satellites pulses has been measured
to be 41± 14% with the Ne jet off, and 38± 13% with the Ne jet on.
Note the slight asymmetry of the pulse that goes through the Ne jet, most
probably due to the dispersion experienced in the Ne gas target. The temporal
profile is in close agreement with the theoretical one computed by Jost Henkel
solving the TDSE for a NIR pulse with λ0 = 760 nm and Kr generating
medium. A precise theoretical estimate of the contrast of the satellites pulses
is particularly difficult, as it relies on the precise measurement not only of the
spectral amplitude, but also of the absolute phase difference between the two
harmonics. It is well known that the relative phase between isolated spectral
features is one of the most challenging tasks in ultrafast pulse characterisation
[57].
In conclusion, in this section I presented the characterisation of three
attosecond pulses generated by selecting different portions of the HHG spec-
trum obtained with a 3.5 fs pulse centred at 790 nm. The characteristics of
these pulses, together with the generating NIR pulse, are summarised in table
5.3.
Spectral range Wavelength Photon energy Duration
NIR 790 nm 1.57 eV 3.5± 0.1 fsXUV 14 nm 90 eV 270± 25 asVUV 62 nm 20 eV 585± 31 asVUV 83 nm 15 eV 1.7± 0.1 fs
Table 5.3: Summary of the pulses presented in this work.
161
Chapter 6
Conclusions and future work
In this thesis I have presented new methods for the characterisation of ultrafast
pulses and the development of new attosecond sources and their characterisa-
tion.
In chapter 3 I presented the CEP performance of our hollow core fibre pulse
compression setup. These results showed that when scaling the energy input
to higher levels, ionisation-induced instabilities degrade the CEP stability, and
that ionisation defocusing couples energy to higher order modes, degrading the
transmission performance of the fibre setup. To overcome these limitations,
fibres with a bigger inner diameter are being tested (400 μm compared to the
260 μm used for the measurements presented). Moreover, a better vacuum
system is under development to lower the pressure at the fibre entrance and to
house the focusing optic coupling the NIR pulse into the fibre. This will allow
us to remove any non-linear effect due to the focused NIR pulse going through
the entrance window of the vacuum system. With these improvements we aim
to couple the full 2.5 mJ available from our CPA laser system into our hollow
fibre, giving a 3.5 fs laser pulse with up to 1.2-1.3 mJ of pulse energy.
I described in chapter 3 high harmonics generated in ablation plumes. This
type of source is an interesting alternative for the generation of XUV radiation
via HHG in gas targets. In particular we showed that the spatial coherence
properties of the radiation generated in ablation plumes are comparable to
162 CHAPTER 6. CONCLUSIONS AND FUTURE WORK
the more standard high harmonics generated in rare gases. The next step
is their temporal characterisation. Preliminary measurements preformed by
Z. Abdelrahman show that the photon yield of the harmonics generated in
ablation plumes is comparable to rare gases. For this reason an attosecond
streaking experiment for the temporal characterisation of the isolated spectral
features seen in Zn (see figure 3.25) seems now possible.
I presented two characterisation techniques for few-cycle pulses in chapter
4. The first technique presented was a single-shot implementation of the d-
scan technique. The dispersion scan is mapped on the spatial profile of the
pulse by using a Littrow prism. An imaging spectrometer was used to record
the second harmonic signal as a function of position/dispersion, thus allowing
us to record a d-scan trace on a single shot basis. The retrieved pulse duration
of 3.3 ± 0.3 fs is compatible with the 3.2 ± 0.1 fs duration obtained by an
independent d-scan measurement of the same pulse (see figure 4.6). Further
developments of this single-shot implementation require the design of a more
compact setup, and a study of the maximum dispersion range achievable.
The second characterisation technique presented was the ARIES technique.
Exploiting the dependence of the HHG cut-off position on the precise wave-
form of the generating few-cycle pulse, this technique was able to successfully
characterise test-pulses of few-cycle duration and different CEP values, and
also test-pulses significantly different from their respective FTL with pulse du-
rations as long as 18 fs (see figures 4.11 and 4.12). A very interesting aspect
of this technique is the possibility of measuring pulses with components at
twice the frequency of the pulse used for HHG. This means that, in principle,
the full waveform of a ω + 2ω pulse, for example, can be retrieved with this
method. The measurement of such a waveform has been performed only with
attosecond streaking so far [16]. Future work is planned to synthesise a ω+2ω
field that may improve the contrast of our attosecond VUV pulses. The ARIES
technique could be used to characterise the ω + 2ω field.
I presented in chapter 4 the design of a dual electron VMI and ion TOF
CHAPTER 6. CONCLUSIONS AND FUTURE WORK 163
spectrometer designed to resolve photoelectrons up to 90 eV and with a ion
mass resolution of ions up to 1% at 80 a.u. This device is now installed and
in operation. Future work using this apparatus will proceed in a number
of directions. We will perform streaking measurements of the XUV pulse
to compare the performance of the VMI to the electron TOF for attosecond
streaking. Moreover the higher collection efficiency and the flexibility on the
optimisation of the energy resolution may allow a easier/quicker measurement
of the XUV and VUV pulses. Once the setup is optimised the first experiments
using covariance mapping between the electron VMI and ion TOF signal can
be performed.
The main result of this thesis has been the production and characterisation
of two pulses in the VUV range synchronised with an isolated XUV pulse
generated at the same time in a double gas jet setup. A pulse duration of
1.7±0.1 fs has been achieved at a photon energy of 15 eV (83 nm) and a pulse
duration of 585 ± 31 as has been measured at 20 eV (62 nm). These pulses
have been obtained by filtering the spectrum of high harmonics generated in
Kr with a few cycle NIR pulse (3.5 fs) using In and Sn foils respectively. I
verified experimentally that these pulses could be generated simultaneously
with an XUV pulse (270± 25 as at 90 eV), opening up new opportunities for
attosecond-pump attosecond-probe experiments.
In order to understand better the generation dynamics of these pulses,
especially the VUV pulses, their characterisation could be performed under
different experimental conditions. In particular the installation of the electron
VMI spectrometer should allow a faster measurement of the streaking traces.
For this reason one could explore the dependence of the temporal profile of
the generated pulses for different CEP values and intensity of the generating
NIR pulse, in order to verify if the experimental parameters used in this thesis
are indeed optimal. Moreover the in-line geometry of the gas targets we used
has been shown to produce an enhancement of the XUV yield [152]. This
enhancement has been seen in [152] for high gas pressures in the first gas jet,
164 CHAPTER 6. CONCLUSIONS AND FUTURE WORK
when the low low harmonics (3-7 eV), generated in the first jet, were efficiently
produced, while the efficiency for the higher order harmonics (> 20 eV) was
reduced. In the results I presented for the VUV pulses, the experimental
conditions were rather different. The pressure of the first jet was kept low
in order to minimise the effect on the XUV pulse generation in the second
jet. However it may be possible for us to reproduce the enhancement feature
presented by Brizuela et al. by increasing to higher levels the pressure in the
first jet.
The unique feature of the attosecond source I have developed is the capa-
bility of delivering any pair of the pulses to an experiment, with attosecond
resolution. The in-line geometry of the gas targets does not require any auxil-
iary stabilisation procedure to recombine the two pulses with attosecond preci-
sion. This capability opens up the possibility of performing attosecond-pump
attosecond-probe experiments with different photon energies for the pump and
for the probe step. The VUV pulses are well suited to many molecular tar-
gets which typically have high photoionisation cross sections in this spectral
region. In the work of B. Cooper and V. Averbukh [153] they suggest that a
VUV pulse, similar to the one I characterised, could probe the hole migration in
ionised glycine. The technique proposed is called single-photon laser-enabled
Auger decay (spLEAD). In this case the initial ionisation step does not di-
rectly allow a two-electron Auger-like transition [154] since the ionised state
does not have enough energy. The missing energy can be provided by the
probe-pulse in the so called Laser Enabled Auger Decay (LEAD) [155, 156]. In
sp-LEAD, the energy is provided by a single VUV photon and the simulations
performed showed that the timing of the VUV photon is sensitive to the hole
dynamics and therefore the hole migration can be extracted from the sp-LEAD
photoelectron yield.
This is an example of how the new tools developed in this thesis are a valu-
able resource for the development of new attosecond pump-probe experiments.
165
Bibliography
[1] P. M. Paul et al. “Observation of a Train of Attosecond Pulses from High
Harmonic Generation”. en. In: Science 292.5522 (June 2001), pp. 1689–
1692. doi: 10.1126/science.1059413 (cit. on p. 15).
[2] M. Hentschel et al. “Attosecond metrology”. en. In: Nature 414.6863
(Nov. 2001), pp. 509–513. doi: 10.1038/35107000 (cit. on p. 15).
[3] Ferenc Krausz and Misha Ivanov. “Attosecond physics”. In: Reviews of
Modern Physics 81.1 (Feb. 2009), pp. 163–234. doi: 10.1103/RevMod
Phys.81.163 (cit. on pp. 15, 16, 68, 99).
[4] M. Uiberacker et al. “Attosecond real-time observation of electron tun-
nelling in atoms”. en. In: Nature 446.7136 (Apr. 2007), pp. 627–632.
doi: 10.1038/nature05648 (cit. on p. 15).
[5] M. Drescher et al. “Time-resolved atomic inner-shell spectroscopy”. en.
In: Nature 419.6909 (Oct. 2002), pp. 803–807. doi: 10.1038/nature0
1143 (cit. on p. 15).
[6] A. L. Cavalieri et al. “Attosecond spectroscopy in condensed matter”.
en. In: Nature 449.7165 (Oct. 2007), pp. 1029–1032. doi: 10.1038/na
ture06229 (cit. on p. 15).
[7] M. Schultze et al. “Delay in Photoemission”. en. In: Science 328.5986
(June 2010), pp. 1658–1662. doi: 10.1126/science.1189401 (cit. on
pp. 15, 148).
166 BIBLIOGRAPHY
[8] S. Baker et al. “Probing Proton Dynamics in Molecules on an Attosecond
Time Scale”. en. In: Science 312.5772 (Apr. 2006), pp. 424–427. doi:
10.1126/science.1123904 (cit. on pp. 15, 58).
[9] Siegfried Lunnemann, Alexander I. Kuleff, and Lorenz S. Cederbaum.
“Ultrafast charge migration in 2-phenylethyl-N,N-dimethylamine”. In:
Chemical Physics Letters 450.4–6 (Jan. 2008), pp. 232–235. doi: 10.1
016/j.cplett.2007.11.031 (cit. on p. 15).
[10] Louise Belshaw et al. “Observation of Ultrafast Charge Migration in an
Amino Acid”. In: The Journal of Physical Chemistry Letters 3.24 (Dec.
2012), pp. 3751–3754. doi: 10.1021/jz3016028 (cit. on pp. 15, 16).
[11] Michael Kruger, Markus Schenk, and Peter Hommelhoff. “Attosecond
control of electrons emitted from a nanoscale metal tip”. en. In: Nature
475.7354 (July 2011), pp. 78–81. doi: 10.1038/nature10196 (cit. on
p. 15).
[12] S. Neppl et al. “Attosecond Time-Resolved Photoemission from Core
and Valence States of Magnesium”. In: Physical Review Letters 109.8
(Aug. 2012), p. 087401. doi: 10.1103/PhysRevLett.109.087401 (cit.
on p. 15).
[13] M. Lewenstein et al. “Theory of high-harmonic generation by low-
frequency laser fields”. In: Physical Review A 49.3 (Mar. 1994), pp. 2117–
2132. doi: 10.1103/PhysRevA.49.2117 (cit. on pp. 15, 54).
[14] Morgane Vacher, Michael J. Bearpark, and Michael A. Robb. “Com-
munication: Oscillating charge migration between lone pairs persists
without significant interaction with nuclear motion in the glycine and
Gly-Gly-NH-CH3 radical cations”. In: The Journal of Chemical Physics
140.20 (May 2014), p. 201102. doi: 10.1063/1.4879516 (cit. on p. 16).
[15] Ian A. Walmsley and Christophe Dorrer. “Characterization of ultra-
short electromagnetic pulses”. In: Advances in Optics and Photonics
BIBLIOGRAPHY 167
1.2 (Apr. 2009), pp. 308–437. doi: 10.1364/AOP.1.000308 (cit. on
pp. 16, 42, 45, 99).
[16] A. Wirth et al. “Synthesized Light Transients”. en. In: Science 334.6053
(Oct. 2011), pp. 195–200. doi: 10.1126/science.1210268 (cit. on
pp. 16, 68, 99, 109, 118, 162).
[17] Miguel Miranda et al. “Characterization of broadband few-cycle laser
pulses with the d-scan technique”. In: Optics Express 20.17 (Aug. 2012),
pp. 18732–18743. doi: 10.1364/OE.20.018732 (cit. on pp. 16, 99–101,
193).
[18] Kyung Taec Kim et al. “Petahertz optical oscilloscope”. en. In: Nature
Photonics advance online publication (Nov. 2013). doi: 10.1038/npho
ton.2013.286 (cit. on pp. 16, 109, 110).
[19] Tenio Popmintchev et al. “Bright Coherent Ultrahigh Harmonics in
the keV X-ray Regime from Mid-Infrared Femtosecond Lasers”. en. In:
Science 336.6086 (June 2012), pp. 1287–1291. doi: 10.1126/science.
1218497 (cit. on pp. 16, 17).
[20] Kun Zhao et al. “Tailoring a 67 attosecond pulse through advantageous
phase-mismatch”. In: Optics Letters 37.18 (Sept. 2012), pp. 3891–3893.
doi: 10.1364/OL.37.003891 (cit. on pp. 16, 58).
[21] Hiroki Mashiko et al. “Tunable frequency-controlled isolated attosecond
pulses characterized by either 750 nm or 400 nm wavelength streak
fields”. In: Optics Express 18.25 (Nov. 2010), p. 25887. doi: 10.136
4/OE.18.025887 (cit. on pp. 17, 127).
[22] P. Tzallas et al. “Extreme-ultraviolet pump-probe studies of one-femtosecond-
scale electron dynamics”. en. In: Nature Physics 7.10 (2011), pp. 781–
784. doi: 10.1038/nphys2033 (cit. on p. 17).
168 BIBLIOGRAPHY
[23] Fabio Frassetto et al. “Single-grating monochromator for extreme-ultraviolet
ultrashort pulses”. In: Optics Express 19.20 (Sept. 2011), pp. 19169–
19181. doi: 10.1364/OE.19.019169 (cit. on p. 17).
[24] Rashid A. Ganeev et al. “Strong resonance enhancement of a single
harmonic generated in the extreme ultraviolet range”. In: Optics Letters
31.11 (June 2006), pp. 1699–1701. doi: 10.1364/OL.31.001699 (cit. on
pp. 17, 93).
[25] Kosei Kameta et al. “Photoabsorption, photoionization, and neutral-
dissociation cross sections of simple hydrocarbons in the vacuum ul-
traviolet range”. In: Journal of Electron Spectroscopy and Related Phe-
nomena 123.2–3 (May 2002), pp. 225–238. doi: 10.1016/S0368-204
8(02)00022-1 (cit. on p. 17).
[26] U. Graf et al. “Intense few-cycle light pulses in the deep ultraviolet”.
In: Optics Express 16.23 (Nov. 2008), pp. 18956–18963. doi: 10.136
4/OE.16.018956 (cit. on p. 17).
[27] Florentin Reiter et al. “Generation of sub-3 fs pulses in the deep ul-
traviolet”. In: Optics Letters 35.13 (July 2010), pp. 2248–2250. doi:
10.1364/OL.35.002248 (cit. on p. 17).
[28] Marcus Beutler, Masood Ghotbi, and Frank Noack. “Generation of in-
tense sub-20-fs vacuum ultraviolet pulses compressed by material dis-
persion”. In: Optics Letters 36.19 (Oct. 2011), pp. 3726–3728. doi:
10.1364/OL.36.003726 (cit. on p. 17).
[29] P. St J. Russell et al. “Hollow-core photonic crystal fibres for gas-based
nonlinear optics”. en. In: Nature Photonics 8.4 (Apr. 2014), pp. 278–
286. doi: 10.1038/nphoton.2013.312 (cit. on p. 17).
[30] Ximao Feng et al. “Generation of Isolated Attosecond Pulses with 20
to 28 Femtosecond Lasers”. In: Physical Review Letters 103.18 (Oct.
2009), p. 183901. doi: 10.1103/PhysRevLett.103.183901 (cit. on
pp. 17, 83).
BIBLIOGRAPHY 169
[31] Jost Henkel et al. “Prediction of attosecond light pulses in the VUV
range in a high-order-harmonic-generation regime”. In: Physical Review
A 87.4 (Apr. 2013), p. 043818. doi: 10.1103/PhysRevA.87.043818 (cit.
on pp. 19, 151, 154).
[32] William A. Okell et al. “Carrier-envelope phase stability of hollow fibers
used for high-energy few-cycle pulse generation”. In: Optics Letters
38.19 (Oct. 2013), pp. 3918–3921. doi: 10.1364/OL.38.003918 (cit. on
pp. 19, 68, 71, 72, 75, 78–80, 193).
[33] R. A. Ganeev et al. “Spatial coherence measurements of non-resonant
and resonant high harmonics generated in laser ablation plumes”. In:
Applied Physics Letters 104.2 (Jan. 2014), p. 021122. doi: 10.1063/1.
4861161 (cit. on pp. 19, 85, 93, 95–97, 193).
[34] A. E. Siegman. Lasers. en. University Science Books, Jan. 1986 (cit. on
p. 23).
[35] R. L. Fork, O. E. Martinez, and J. P. Gordon. “Negative dispersion
using pairs of prisms”. In: Optics Letters 9.5 (May 1984), pp. 150–152.
doi: 10.1364/OL.9.000150 (cit. on pp. 28, 29).
[36] E. Treacy. “Optical pulse compression with diffraction gratings”. In:
IEEE Journal of Quantum Electronics 5.9 (Sept. 1969), pp. 454–458.
doi: 10.1109/JQE.1969.1076303 (cit. on pp. 28, 29).
[37] Robert Szipocs et al. “Chirped multilayer coatings for broadband dis-
persion control in femtosecond lasers”. In: Optics Letters 19.3 (Feb.
1994), pp. 201–203. doi: 10.1364/OL.19.000201 (cit. on p. 29).
[38] Volodymyr Pervak. “Recent development and new ideas in the field
of dispersive multilayer optics”. In: Applied Optics 50.9 (Mar. 2011),
pp. C55–C61. doi: 10.1364/AO.50.000C55 (cit. on p. 29).
170 BIBLIOGRAPHY
[39] Pierre Tournois. “Acousto-optic programmable dispersive filter for adap-
tive compensation of group delay time dispersion in laser systems”.
In: Optics Communications 140.4–6 (Aug. 1997), pp. 245–249. doi:
10.1016/S0030-4018(97)00153-3 (cit. on pp. 30, 66).
[40] G. New. Introduction to Nonlinear Optics. en. Cambridge University
Press, May 2011 (cit. on p. 34).
[41] P. F. Moulton. “Spectroscopic and laser characteristics of Ti:Al2O3”.
In: Journal of the Optical Society of America B 3.1 (Jan. 1986), pp. 125–
133. doi: 10.1364/JOSAB.3.000125 (cit. on pp. 36, 38).
[42] L. E. Hargrove, R. L. Fork, and M. A. Pollack. “Locking of He–Ne laser
modes induced by synchronous intracavity modulation”. In: Applied
Physics Letters 5.1 (July 1964), pp. 4–5. doi: 10.1063/1.1754025
(cit. on p. 36).
[43] Willis E. Lamb. “Theory of an Optical Maser”. In: Physical Review
134.6A (June 1964), A1429–A1450. doi: 10.1103/PhysRev.134.A1429
(cit. on p. 36).
[44] U. Morgner et al. “Sub-two-cycle pulses from a Kerr-lens mode-locked
Ti:sapphire laser”. In: Optics Letters 24.6 (Mar. 1999), pp. 411–413.
doi: 10.1364/OL.24.000411 (cit. on p. 36).
[45] D. E. Spence, P. N. Kean, and W. Sibbett. “60-fsec pulse generation
from a self-mode-locked Ti:sapphire laser”. In: Optics Letters 16.1 (Jan.
1991), pp. 42–44. doi: 10.1364/OL.16.000042 (cit. on p. 36).
[46] Joachim Herrmann. “Theory of Kerr-lens mode locking: role of self-
focusing and radially varying gain”. In: Journal of the Optical Society
of America B 11.3 (Mar. 1994), pp. 498–512. doi: 10.1364/JOSAB.1
1.000498 (cit. on p. 36).
BIBLIOGRAPHY 171
[47] Stefan Rausch et al. “Controlled waveforms on the single-cycle scale
from a femtosecond oscillator”. In: Optics Express 16.13 (June 2008),
pp. 9739–9745. doi: 10.1364/OE.16.009739 (cit. on p. 37).
[48] Donna Strickland and Gerard Mourou. “Compression of amplified chirped
optical pulses”. In: Optics Communications 55.6 (Oct. 1985), pp. 447–
449. doi: 10.1016/0030-4018(85)90151-8 (cit. on p. 37).
[49] Jung-Ho Chung and AM.Weiner. “Ambiguity of ultrashort pulse shapes
retrieved from the intensity autocorrelation and the power spectrum”.
In: IEEE Journal of Selected Topics in Quantum Electronics 7.4 (July
2001), pp. 656–666. doi: 10.1109/2944.974237 (cit. on p. 42).
[50] Jean-Claude M. Diels et al. “Control and measurement of ultrashort
pulse shapes (in amplitude and phase) with femtosecond accuracy”. In:
Applied Optics 24.9 (May 1985), pp. 1270–1282. doi: 10.1364/AO.24.
001270 (cit. on p. 42).
[51] Toshiyuki Hirayama and Mansoor Sheik-Bahae. “Real-time chirp diag-
nostic for ultrashort laser pulses”. In: Optics Letters 27.10 (May 2002),
pp. 860–862. doi: 10.1364/OL.27.000860 (cit. on p. 42).
[52] Daniel A. Bender, Jeffrey W. Nicholson, and Mansoor Sheik-Bahae.
“Ultrashort laser pulse characterization using modified spectrum auto-
interferometric correlation (MOSAIC)”. In: Optics Express 16.16 (Aug.
2008), pp. 11782–11794. doi: 10.1364/OE.16.011782 (cit. on p. 42).
[53] Rick Trebino et al. “Measuring ultrashort laser pulses in the time-
frequency domain using frequency-resolved optical gating”. In: Review
of Scientific Instruments 68.9 (Sept. 1997), pp. 3277–3295. doi: 10.10
63/1.1148286 (cit. on pp. 42, 44, 190).
[54] D.J. Kane and R. Trebino. “Characterization of arbitrary femtosecond
pulses using frequency-resolved optical gating”. In: IEEE Journal of
Quantum Electronics 29.2 (Feb. 1993), pp. 571–579. doi: 10.1109/3.
199311 (cit. on p. 42).
172 BIBLIOGRAPHY
[55] Daniel J. Kane. “Principal components generalized projections: a review
[Invited]”. In: Journal of the Optical Society of America B 25.6 (June
2008), A120–A132. doi: 10.1364/JOSAB.25.00A120 (cit. on pp. 44,
130, 187, 188).
[56] C. Iaconis and I.A. Walmsley. “Spectral phase interferometry for direct
electric-field reconstruction of ultrashort optical pulses”. In: Optics Let-
ters 23.10 (May 1998), pp. 792–794. doi: 10.1364/OL.23.000792 (cit.
on p. 45).
[57] Dane R. Austin, Tobias Witting, and Ian A. Walmsley. “High precision
self-referenced phase retrieval of complex pulses with multiple-shearing
spectral interferometry”. In: Journal of the Optical Society of America
B 26.9 (Sept. 2009), pp. 1818–1830. doi: 10.1364/JOSAB.26.001818
(cit. on pp. 47, 159).
[58] T. Witting et al. “Sub-4-fs laser pulse characterization by spatially re-
solved spectral shearing interferometry and attosecond streaking”. en.
In: Journal of Physics B: Atomic, Molecular and Optical Physics 45.7
(Apr. 2012), p. 074014. doi: 10.1088/0953-4075/45/7/074014 (cit.
on pp. 47, 68, 82, 193).
[59] T. Wittmann et al. “Single-shot carrier–envelope phase measurement of
few-cycle laser pulses”. en. In: Nature Physics 5.5 (May 2009), pp. 357–
362. doi: 10.1038/nphys1250 (cit. on p. 48).
[60] Tim Paasch-Colberg et al. “Solid-state light-phase detector”. en. In:
Nature Photonics 8.3 (Mar. 2014), pp. 214–218. doi: 10.1038/nphoto
n.2013.348 (cit. on pp. 48, 109).
[61] R. Holzwarth et al. “Optical Frequency Synthesizer for Precision Spec-
troscopy”. In: Physical Review Letters 85.11 (Sept. 2000), pp. 2264–
2267. doi: 10.1103/PhysRevLett.85.2264 (cit. on p. 48).
BIBLIOGRAPHY 173
[62] David J. Jones et al. “Carrier-Envelope Phase Control of Femtosecond
Mode-Locked Lasers and Direct Optical Frequency Synthesis”. en. In:
Science 288.5466 (Apr. 2000), pp. 635–639. doi: 10.1126/science.28
8.5466.635 (cit. on p. 49).
[63] Steven T. Cundiff. “Femtosecond combs: Simplified stabilization”. en.
In: Nature Photonics 4.7 (July 2010), pp. 410–411. doi: 10.1038/nph
oton.2010.141 (cit. on p. 49).
[64] Sebastian Koke et al. “Direct frequency comb synthesis with arbitrary
offset and shot-noise-limited phase noise”. en. In: Nature Photonics 4.7
(July 2010), pp. 462–465. doi: 10.1038/nphoton.2010.91 (cit. on
p. 49).
[65] A. Einstein. “Uber einen die Erzeugung und Verwandlung des Lichtes
betreffenden heuristischen Gesichtspunkt”. en. In: Annalen der Physik
322.6 (Jan. 1905), pp. 132–148. doi: 10.1002/andp.19053220607 (cit.
on p. 50).
[66] E. A. Martin and L. Mandel. “Electron energy spectrum in laser-induced
multiphoton ionization of atoms”. In: Applied Optics 15.10 (Oct. 1976),
pp. 2378–2380. doi: 10.1364/AO.15.002378 (cit. on p. 50).
[67] Z. Deng and J. H. Eberly. “Multiphoton absorption above ionization
threshold by atoms in strong laser fields”. In: Journal of the Optical
Society of America B 2.3 (Mar. 1985), pp. 486–493. doi: 10.1364/JOS
AB.2.000486 (cit. on p. 50).
[68] F. Fabre et al. “Multiphoton above-threshold ionisation of xenon at
0.53 and 1.06μm”. en. In: Journal of Physics B: Atomic and Molecular
Physics 15.9 (May 1982), p. 1353. doi: 10.1088/0022-3700/15/9/012
(cit. on p. 50).
[69] S. Augst et al. “Tunneling ionization of noble gases in a high-intensity
laser field”. In: Physical Review Letters 63.20 (Nov. 1989), pp. 2212–
2215. doi: 10.1103/PhysRevLett.63.2212 (cit. on pp. 50, 51).
174 BIBLIOGRAPHY
[70] L. V. Keldysh. “Ionization in the field of a strong electromagnetic
wave”. In: Soviet Physics JETP 20.5 (May 1965), pp. 1307–1314 (cit.
on p. 51).
[71] M. V. Ammosov, N. B. Delone, and V. P. Krainov. “Tunnell ionization
of complex atoms and of atomic ions in alternating electromagnetic
field”. In: Soviet Physics JETP 64.6 (Dec. 1986), pp. 1191–1194 (cit.
on p. 52).
[72] P. B. Corkum. “Plasma perspective on strong field multiphoton ioniza-
tion”. In: Physical Review Letters 71.13 (Sept. 1993), pp. 1994–1997.
doi: 10.1103/PhysRevLett.71.1994 (cit. on p. 54).
[73] K. J. Schafer et al. “Above threshold ionization beyond the high har-
monic cutoff”. In: Physical Review Letters 70.11 (Mar. 1993), pp. 1599–
1602. doi: 10.1103/PhysRevLett.70.1599 (cit. on p. 54).
[74] A. D. Shiner et al. “Wavelength Scaling of High Harmonic Generation
Efficiency”. In: Physical Review Letters 103.7 (Aug. 2009), p. 073902.
doi: 10.1103/PhysRevLett.103.073902 (cit. on p. 57).
[75] Mette B. Gaarde, Jennifer L. Tate, and Kenneth J. Schafer. “Macro-
scopic aspects of attosecond pulse generation”. en. In: Journal of Physics
B: Atomic, Molecular and Optical Physics 41.13 (July 2008), p. 132001.
doi: 10.1088/0953-4075/41/13/132001 (cit. on pp. 59, 61, 81).
[76] Philippe Balcou et al. “Generalized phase-matching conditions for high
harmonics: The role of field-gradient forces”. In: Physical Review A 55.4
(Apr. 1997), pp. 3204–3210. doi: 10.1103/PhysRevA.55.3204 (cit. on
p. 60).
[77] L. E. Chipperfield et al. “Tracking individual electron trajectories in a
high harmonic spectrum”. In: Optics Communications. Quantum Con-
trol of Light and Matter In honor of the 70th birthday of Bruce Shore
264.2 (Aug. 2006), pp. 494–501. doi: 10.1016/j.optcom.2006.03.078
(cit. on pp. 62, 193).
BIBLIOGRAPHY 175
[78] C. Vozzi et al. “Generalized molecular orbital tomography”. en. In:
Nature Physics 7.10 (Oct. 2011), pp. 822–826. doi: 10.1038/nphys2029
(cit. on p. 61).
[79] F. Frank et al. “Invited Review Article: Technology for Attosecond
Science”. In: Review of Scientific Instruments 83.7 (2012), p. 071101.
doi: 10.1063/1.4731658 (cit. on pp. 63, 84, 139, 142).
[80] M. Nisoli, S. De Silvestri, and O. Svelto. “Generation of high energy 10
fs pulses by a new pulse compression technique”. In: Applied Physics
Letters 68.20 (May 1996), pp. 2793–2795. doi: 10.1063/1.116609 (cit.
on p. 68).
[81] Samuel Bohman et al. “Generation of 5.0 fs, 5.0 mJ pulses at 1 kHz
using hollow-fiber pulse compression”. In: Optics Letters 35.11 (June
2010), pp. 1887–1889. doi: 10.1364/OL.35.001887 (cit. on pp. 68,
71).
[82] E. Goulielmakis et al. “Single-Cycle Nonlinear Optics”. en. In: Science
320.5883 (June 2008), pp. 1614–1617. doi: 10.1126/science.1157846
(cit. on pp. 68, 191).
[83] Juyun Park, Jae-hwan Lee, and Chang Hee Nam. “Generation of 1.5
cycle 0.3 TW laser pulses using a hollow-fiber pulse compressor”. In:
Optics Letters 34.15 (Aug. 2009), pp. 2342–2344. doi: 10.1364/OL.3
4.002342 (cit. on pp. 68, 71).
[84] Tobias Witting et al. “Characterization of high-intensity sub-4-fs laser
pulses using spatially encoded spectral shearing interferometry”. In:
Optics Letters 36.9 (May 2011), pp. 1680–1682. doi: 10.1364/OL.36.
001680 (cit. on pp. 68, 127).
[85] Claude Rolland and P. B. Corkum. “Compression of high-power optical
pulses”. In: Journal of the Optical Society of America B 5.3 (Mar. 1988),
pp. 641–647. doi: 10.1364/JOSAB.5.000641 (cit. on p. 68).
176 BIBLIOGRAPHY
[86] E. A. J. Marcatili and R. A. Schmeltzer. “Hollow metallic and dielectric
waveguides for long distance optical transmission and lasers”. In: The
bell system technical journal (July 1964) (cit. on p. 68).
[87] M. Nisoli et al. “Toward a terawatt-scale sub-10-fs laser technology”.
In: IEEE Journal of Selected Topics in Quantum Electronics 4.2 (Mar.
1998), pp. 414–420. doi: 10.1109/2944.686749 (cit. on pp. 69, 71).
[88] Nenad Milosevic, Gabriel Tempea, and Thomas Brabec. “Optical pulse
compression: bulk media versus hollow waveguides”. In: Optics Letters
25.9 (May 2000), pp. 672–674. doi: 10.1364/OL.25.000672 (cit. on
p. 71).
[89] Akira Suda et al. “Generation of sub-10-fs, 5-mJ-optical pulses using a
hollow fiber with a pressure gradient”. In: Applied Physics Letters 86.11
(Mar. 2005), p. 111116. doi: 10.1063/1.1883706 (cit. on pp. 71, 72).
[90] J. S. Robinson et al. “The generation of intense, transform-limited laser
pulses with tunable duration from 6 to 30 fs in a differentially pumped
hollow fibre”. en. In: Applied Physics B 85.4 (Dec. 2006), pp. 525–529.
doi: 10.1007/s00340-006-2390-z (cit. on p. 71).
[91] S Petit et al. “Polarization dependence of the propagation of intense
laser pulses in air”. In: Optics Communications 175.4–6 (Mar. 2000).
doi: 10.1016/S0030-4018(00)00494-6 (cit. on p. 71).
[92] S. Ghimire et al. “High-Energy 6.2-fs Pulses for Attosecond Pulse Gen-
eration”. In: Laser Physics 15.6 (2005), pp. 838–842 (cit. on p. 71).
[93] Xiaowei Chen et al. “Generation of 4.3 fs, 1 mJ laser pulses via com-
pression of circularly polarized pulses in a gas-filled hollow-core fiber”.
In: Optics Letters 34.10 (May 2009), pp. 1588–1590. doi: 10.1364/OL.
34.001588 (cit. on p. 71).
BIBLIOGRAPHY 177
[94] C. Vozzi et al. “Optimal spectral broadening in hollow-fiber compressor
systems”. en. In: Applied Physics B 80.3 (Mar. 2005), pp. 285–289. doi:
10.1007/s00340-004-1721-1 (cit. on pp. 71–73).
[95] S. V. Chernikov and J. R. Taylor. “Measurement of normalization factor
of n2 for random polarization in optical fibers”. In: Optics Letters 21.19
(Oct. 1996), pp. 1559–1561. doi: 10.1364/OL.21.001559 (cit. on p. 72).
[96] He Wang et al. “Coupling between energy and phase in hollow-core fiber
based f-to-2f interferometers”. In: Optics Express 17.14 (July 2009),
pp. 12082–12089. doi: 10.1364/OE.17.012082 (cit. on p. 80).
[97] I. J. Sola et al. “Controlling attosecond electron dynamics by phase-
stabilized polarization gating”. en. In: Nature Physics 2.5 (May 2006),
pp. 319–322. doi: 10.1038/nphys281 (cit. on p. 82).
[98] G. Sansone et al. “Isolated Single-Cycle Attosecond Pulses”. en. In:
Science 314.5798 (Oct. 2006), pp. 443–446. doi: 10.1126/science.11
32838 (cit. on p. 82).
[99] P. Dietrich et al. “High-harmonic generation and correlated two-electron
multiphoton ionization with elliptically polarized light”. In: Physical
Review A 50.5 (Nov. 1994), R3585–R3588. doi: 10.1103/PhysRevA.5
0.R3585 (cit. on p. 82).
[100] Hiroki Mashiko et al. “Double Optical Gating of High-Order Harmonic
Generation with Carrier-Envelope Phase Stabilized Lasers”. In: Physi-
cal Review Letters 100.10 (Mar. 2008), p. 103906. doi: 10.1103/Phys
RevLett.100.103906 (cit. on p. 82).
[101] F. Ferrari et al. “High-energy isolated attosecond pulses generated by
above-saturation few-cycle fields”. en. In: Nature Photonics 4.12 (Dec.
2010), pp. 875–879. doi: 10.1038/nphoton.2010.250 (cit. on p. 83).
178 BIBLIOGRAPHY
[102] H. Vincenti and F. Quere. “Attosecond Lighthouses: How To Use Spa-
tiotemporally Coupled Light Fields To Generate Isolated Attosecond
Pulses”. In: Physical Review Letters 108.11 (Mar. 2012), p. 113904.
doi: 10.1103/PhysRevLett.108.113904 (cit. on p. 83).
[103] Kyung Taec Kim et al. “Photonic streaking of attosecond pulse trains”.
en. In: Nature Photonics advance online publication (July 2013). doi:
10.1038/nphoton.2013.170 (cit. on p. 83).
[104] Jonathan A. Wheeler et al. “Attosecond lighthouses from plasma mir-
rors”. en. In: Nature Photonics 6.12 (Dec. 2012), pp. 829–833. doi:
10.1038/nphoton.2012.284 (cit. on p. 83).
[105] E. M. Bothschafter et al. “Collinear generation of ultrashort UV and
XUV pulses”. In: Optics Express 18.9 (Apr. 2010), pp. 9173–9180. doi:
10.1364/OE.18.009173 (cit. on p. 84).
[106] Toshiaki Kita et al. “Mechanically ruled aberration-corrected concave
gratings for a flat-field grazing-incidence spectrograph”. In: Applied Op-
tics 22.4 (Feb. 1983), pp. 512–513. doi: 10.1364/AO.22.000512 (cit.
on p. 85).
[107] R. A. Ganeev. “High-order harmonic generation in a laser plasma: a
review of recent achievements”. en. In: Journal of Physics B: Atomic,
Molecular and Optical Physics 40.22 (Nov. 2007), R213. doi: 10.108
8/0953-4075/40/22/R01 (cit. on p. 93).
[108] R. A. Ganeev et al. “Isolated sub-fs XUV pulse generation in Mn plasma
ablation”. In: Optics Express 20.23 (Nov. 2012), pp. 25239–25248. doi:
10.1364/OE.20.025239 (cit. on p. 93).
[109] V. Strelkov. “Role of Autoionizing State in Resonant High-Order Har-
monic Generation and Attosecond Pulse Production”. In: Physical Re-
view Letters 104.12 (Mar. 2010), p. 123901. doi: 10.1103/PhysRev
Lett.104.123901 (cit. on pp. 93, 94, 193).
BIBLIOGRAPHY 179
[110] Christopher Hutchison et al. “Stable generation of high-order harmon-
ics of femtosecond laser radiation from laser produced plasma plumes
at 1 kHz pulse repetition rate”. In: Optics Letters 37.11 (June 2012),
pp. 2064–2066. doi: 10.1364/OL.37.002064 (cit. on p. 94).
[111] A. Kramida et al. NIST Atomic Spectra Database (ver. 5.2), [Online].
Available: http://physics.nist.gov/asd [2015, March 12]. National
Institute of Standards and Technology, Gaithersburg, MD. 2014 (cit. on
p. 95).
[112] K. A. Dick. “The spark spectra of zinc. II. Zinc III”. In: Canadian
Journal of Physics 46.11 (June 1968), pp. 1291–1302. doi: 10.1139/p
68-449 (cit. on p. 95).
[113] Grainne Duffy and Padraig Dunne. “The photoabsorption spectrum
of an indium laser produced plasma”. en. In: Journal of Physics B:
Atomic, Molecular and Optical Physics 34.6 (Mar. 2001), p. L173. doi:
10.1088/0953-4075/34/6/104 (cit. on p. 95).
[114] T. Ditmire et al. “Spatial coherence of short wavelength high-order
harmonics”. en. In: Applied Physics B 65.3 (Sept. 1997), pp. 313–328.
doi: 10.1007/s003400050278 (cit. on p. 96).
[115] T. Ditmire et al. “Spatial Coherence Measurement of Soft X-Ray Ra-
diation Produced by High Order Harmonic Generation”. In: Physi-
cal Review Letters 77.23 (Dec. 1996), pp. 4756–4759. doi: 10 . 110
3/PhysRevLett.77.4756 (cit. on p. 97).
[116] Richard L. Sandberg et al. “Lensless Diffractive Imaging Using Table-
top Coherent High-Harmonic Soft-X-Ray Beams”. In: Physical Review
Letters 99.9 (Aug. 2007), p. 098103. doi: 10.1103/PhysRevLett.99.0
98103 (cit. on p. 97).
[117] E. Esarey, C. B. Schroeder, and W. P. Leemans. “Physics of laser-driven
plasma-based electron accelerators”. In: Reviews of Modern Physics
180 BIBLIOGRAPHY
81.3 (Aug. 2009), pp. 1229–1285. doi: 10.1103/RevModPhys.81.1229
(cit. on p. 99).
[118] Francisco Silva et al. “Simultaneous compression, characterization and
phase stabilization of GW-level 14 cycle VIS-NIR femtosecond pulses
using a single dispersion-scan setup”. en. In: Optics Express 22.9 (May
2014), p. 10181. doi: 10.1364/OE.22.010181 (cit. on pp. 99, 101, 108).
[119] Vincent Loriot, Gregory Gitzinger, and Nicolas Forget. “Self-referenced
characterization of femtosecond laser pulses by chirp scan”. In: Optics
Express 21.21 (Oct. 2013), pp. 24879–24893. doi: 10.1364/OE.21.024
879 (cit. on p. 100).
[120] Miguel Miranda et al. “Simultaneous compression and characterization
of ultrashort laser pulses using chirped mirrors and glass wedges”. In:
Optics Express 20.1 (Jan. 2012), pp. 688–697. doi: 10.1364/OE.20.00
0688 (cit. on p. 102).
[121] Selcuk Akturk et al. “Measuring spatial chirp in ultrashort pulses us-
ing single-shot Frequency-Resolved Optical Gating”. In: Optics Express
11.1 (Jan. 2003), pp. 68–78. doi: 10.1364/OE.11.000068 (cit. on
p. 102).
[122] Patrice Hello and Catherine Nary Man. “Design of a low-loss off-axis
beam expander”. en. In: Applied Optics 35.15 (May 1996), p. 2534. doi:
10.1364/AO.35.002534 (cit. on p. 103).
[123] Dane R. Austin, Tobias Witting, and Ian A. Walmsley. “Broadband
astigmatism-free Czerny-Turner imaging spectrometer using spherical
mirrors”. In: Applied Optics 48.19 (July 2009), pp. 3846–3853. doi:
10.1364/AO.48.003846 (cit. on p. 104).
[124] Y. Mairesse and F. Quere. “Frequency-resolved optical gating for com-
plete reconstruction of attosecond bursts”. In: Physical Review A 71.1
(Jan. 2005), p. 011401. doi: 10.1103/PhysRevA.71.011401 (cit. on
pp. 109, 128, 129).
BIBLIOGRAPHY 181
[125] Yutaka Nomura, Hideto Shirai, and Takao Fuji. “Frequency-resolved
optical gating capable of carrier-envelope phase determination”. en. In:
Nature Communications 4 (Nov. 2013). doi: 10.1038/ncomms3820 (cit.
on p. 109).
[126] C. A. Haworth et al. “Half-cycle cutoffs in harmonic spectra and robust
carrier-envelope phase retrieval”. en. In: Nature Physics 3.1 (Jan. 2007),
pp. 52–57. doi: 10.1038/nphys463 (cit. on p. 109).
[127] J. Itatani et al. “Attosecond Streak Camera”. In: Physical Review Let-
ters 88.17 (Apr. 2002), p. 173903. doi: 10.1103/PhysRevLett.88.17
3903 (cit. on pp. 110, 144).
[128] H. C. Bandulet et al. “Gating attosecond pulse train generation us-
ing multicolor laser fields”. In: Physical Review A 81.1 (Jan. 2010),
p. 013803. doi: 10.1103/PhysRevA.81.013803 (cit. on p. 118).
[129] C. Hutchison et al. “Electron trajectory control of odd and even order
harmonics in high harmonic generation using an orthogonally polarised
second harmonic field”. In: Journal of Modern Optics 61.7 (Apr. 2014),
pp. 608–614. doi: 10.1080/09500340.2014.901431 (cit. on p. 118).
[130] Erik P. Mansson et al. “Multi-purpose two- and three-dimensional mo-
mentum imaging of charged particles for attosecond experiments at 1
kHz repetition rate”. In: Review of Scientific Instruments 85.12 (Dec.
2014), p. 123304. doi: 10.1063/1.4904372 (cit. on p. 120).
[131] L. J. Frasinski, K. Codling, and P. A. Hatherly. “Covariance Mapping:
A Correlation Method Applied to Multiphoton Multiple Ionization”.
en. In: Science 246.4933 (Nov. 1989), pp. 1029–1031. doi: 10.1126/sc
ience.246.4933.1029 (cit. on p. 120).
[132] L. J. Frasinski et al. “Dynamics of Hollow Atom Formation in Intense
X-Ray Pulses Probed by Partial Covariance Mapping”. In: Physical
Review Letters 111.7 (Aug. 2013), p. 073002. doi: 10.1103/PhysRev
Lett.111.073002 (cit. on p. 120).
182 BIBLIOGRAPHY
[133] C. Bordas et al. “Photoelectron imaging spectrometry: Principle and in-
version method”. In: Review of Scientific Instruments 67.6 (June 1996),
pp. 2257–2268. doi: 10.1063/1.1147044 (cit. on p. 121).
[134] Cameron J. Dasch. “One-dimensional tomography: a comparison of
Abel, onion-peeling, and filtered backprojection methods”. In: Applied
Optics 31.8 (Mar. 1992), pp. 1146–1152. doi: 10.1364/AO.31.001146
(cit. on p. 121).
[135] Gustavo A. Garcia, Laurent Nahon, and Ivan Powis. “Two-dimensional
charged particle image inversion using a polar basis function expan-
sion”. In: Review of Scientific Instruments 75.11 (Nov. 2004), pp. 4989–
4996. doi: 10.1063/1.1807578 (cit. on p. 122).
[136] Vladimir Dribinski et al. “Reconstruction of Abel-transformable im-
ages: The Gaussian basis-set expansion Abel transform method”. In:
Review of Scientific Instruments 73.7 (July 2002), pp. 2634–2642. doi:
10.1063/1.1482156 (cit. on p. 122).
[137] T.A. Carlson. Photoelectron and auger spectroscopy. Plenum Press, 1975
(cit. on p. 122).
[138] J. Cooper and R. N. Zare. “Angular Distribution of Photoelectrons”.
In: The Journal of Chemical Physics 48.2 (Jan. 1968), pp. 942–943.
doi: 10.1063/1.1668742 (cit. on p. 122).
[139] J. Gagnon, E. Goulielmakis, and V. S. Yakovlev. “The accurate FROG
characterization of attosecond pulses from streaking measurements”.
en. In: Applied Physics B 92.1 (July 2008), pp. 25–32. doi: 10.1007/s
00340-008-3063-x (cit. on pp. 128, 130–132, 189, 193).
[140] F. Quere, Y. Mairesse, and J. Itatani. “Temporal characterization of
attosecond XUV fields”. In: Journal of Modern Optics 52.2-3 (Jan.
2005), pp. 339–360. doi: 10 . 1080 / 09500340412331307942 (cit. on
p. 128).
BIBLIOGRAPHY 183
[141] O. Hemmers et al. “High-resolution electron time-of-flight apparatus
for the soft x-ray region”. In: Review of Scientific Instruments 69.11
(Nov. 1, 1998), pp. 3809–3817. doi: 10 . 1063 / 1 . 1149183 (cit. on
p. 139).
[142] Thomas Pfeifer et al. “Measurement and optimization of isolated attosecond
pulse contrast”. In: Optics Letters 34.12 (June 15, 2009), pp. 1819–1821.
doi: 10.1364/OL.34.001819 (cit. on p. 142).
[143] S. Mondal et al. “Photoelectron angular distributions for the two-photon
sequential double ionization of xenon by ultrashort extreme ultraviolet
free electron laser pulses”. en. In: Journal of Physics B: Atomic, Molec-
ular and Optical Physics 46.16 (Aug. 2013), p. 164022. doi: 10.1088/
0953-4075/46/16/164022 (cit. on pp. 148, 151).
[144] D. Guenot et al. “Photoemission-time-delay measurements and calcu-
lations close to the 3$s$-ionization-cross-section minimum in Ar”. In:
Physical Review A 85.5 (May 2012), p. 053424. doi: 10.1103/PhysRev
A.85.053424 (cit. on p. 148).
[145] Caryn Palatchi et al. “Atomic delay in helium, neon, argon and kryp-
ton”. en. In: Journal of Physics B: Atomic, Molecular and Optical
Physics 47.24 (Dec. 2014), p. 245003. doi: 10.1088/0953- 4075/4
7/24/245003 (cit. on p. 148).
[146] Edward C. Y. Inn. “Vacuum ultraviolet spectroscopy: A review”. In:
Spectrochimica Acta 7 (1955), pp. 65–87. doi: 10.1016/0371-1951(5
5)80009-4 (cit. on p. 149).
[147] F. S. Johnson, K. Watanabe, and R. Tousey. “Fluorescent Sensitized
Photomultipliers for Heterochromatic Photometry in the Ultraviolet”.
In: Journal of the Optical Society of America 41.10 (Oct. 1951), pp. 702–
705. doi: 10.1364/JOSA.41.000702 (cit. on p. 149).
184 BIBLIOGRAPHY
[148] Vijay Kumar and A. K. Datta. “Vacuum ultraviolet scintillators: sodium
salicylate and p-terphenyl”. In: Applied Optics 18.9 (May 1979), pp. 1414–
1417. doi: 10.1364/AO.18.001414 (cit. on p. 149).
[149] K. J. Nygaard. “The variation of the quantum efficiency of sodium
salicylate with thickness of material”. en. In: British Journal of Applied
Physics 15.5 (May 1964), p. 597. doi: 10.1088/0508-3443/15/5/419
(cit. on p. 149).
[150] G. V. Marr and J. B. West. “Absolute photoionization cross-section ta-
bles for helium, neon, argon, and krypton in the VUV spectral regions”.
In: Atomic Data and Nuclear Data Tables 18.5 (Nov. 1976), pp. 497–
508. doi: 10.1016/0092-640X(76)90015-2 (cit. on p. 150).
[151] David L. Windt et al. “Optical constants for thin films of Ti, Zr, Nb,
Mo, Ru, Rh, Pd, Ag, Hf, Ta, W, Re, Ir, Os, Pt, and Au from 24 A
to 1216 A”. In: Applied Optics 27.2 (Jan. 1988), pp. 246–278. doi:
10.1364/AO.27.000246 (cit. on p. 151).
[152] F. Brizuela et al. “Efficient high-order harmonic generation boosted by
below-threshold harmonics”. en. In: Scientific Reports 3 (Mar. 2013).
doi: 10.1038/srep01410 (cit. on p. 163).
[153] Bridgette Cooper and Vitali Averbukh. “Single-Photon Laser-Enabled
Auger Spectroscopy for Measuring Attosecond Electron-Hole Dynam-
ics”. In: Physical Review Letters 111.8 (Aug. 2013), p. 083004. doi:
10.1103/PhysRevLett.111.083004 (cit. on p. 164).
[154] J. Breidbach and L. S. Cederbaum. “Migration of holes: Formalism,
mechanisms, and illustrative applications”. In: The Journal of Chemical
Physics 118.9 (Mar. 2003), pp. 3983–3996. doi: 10.1063/1.1540618
(cit. on p. 164).
[155] J. M. Schins et al. “Observation of Laser-Assisted Auger Decay in Ar-
gon”. In: Physical Review Letters 73.16 (Oct. 1994), pp. 2180–2183.
doi: 10.1103/PhysRevLett.73.2180 (cit. on p. 164).
BIBLIOGRAPHY 185
[156] P. Ranitovic et al. “Laser-Enabled Auger Decay in Rare-Gas Atoms”.
In: Physical Review Letters 106.5 (Jan. 2011), p. 053002. doi: 10.110
3/PhysRevLett.106.053002 (cit. on p. 164).
[157] Frederik Bohle et al. “Compression of CEP-stable multi-mJ laser pulses
down to 4 fs in long hollow fibers”. en. In: Laser Physics Letters 11.9
(Sept. 2014), p. 095401. doi: 10.1088/1612-2011/11/9/095401.
[158] P. Eckle et al. “Attosecond Ionization and Tunneling Delay Time Mea-
surements in Helium”. en. In: Science 322.5907 (Dec. 2008), pp. 1525–
1529. doi: 10.1126/science.1163439.
[159] J. A. R. Samson and W. C. Stolte. “Precision measurements of the total
photoionization cross-sections of He, Ne, Ar, Kr, and Xe”. In: Journal
of Electron Spectroscopy and Related Phenomena 123.2–3 (May 2002),
pp. 265–276. doi: 10.1016/S0368-2048(02)00026-9.
[160] J. B. West and J. Morton. “Absolute photoionization cross-section ta-
bles for xenon in the VUV and the soft x-ray regions”. In: Atomic
Data and Nuclear Data Tables 22.2 (Aug. 1978), pp. 103–107. doi:
10.1016/0092-640X(78)90010-4.
[161] I. Pupeza et al. “Compact high-repetition-rate source of coherent 100
eV radiation”. en. In: Nature Photonics 7.8 (Aug. 2013), pp. 608–612.
doi: 10.1038/nphoton.2013.156.
[162] Felix Frank. “Generation and Application of Ultrashort Laser Pulses in
Attosecond Science”. PhD thesis. Imperial College London, 2011.
187
Appendix A
Retrieval algorithms
A.1 PCGPA
The PCGPA [55] is based on the mathematical properties of the outer product
of two vectors. Let us define the pulse and gate as
P =Pi = P (ti)
G =Gi = G(ti)
i =1 · · ·N
(A.1)
In other words the pulse and gate are represented by an array of N sample
points. The outer product is defined as
O = P⊗G =
⎛⎜⎜⎜⎜⎜⎜⎜⎜⎜⎝
P1G1 P1G2 · · · P1GN−1 P1GN
P2G1 P2G2 · · · P2GN−1 P2GN
......
. . ....
...
PN−1G1 PN−1G2 · · · PN−1GN−1 PN−1GN
PNG1 PNG2 · · · PNGN−1 PNGN
⎞⎟⎟⎟⎟⎟⎟⎟⎟⎟⎠(A.2)
The signal matrix from equation (5.2), representation of P · G(t + τ) can
be written as:
188 APPENDIX A. RETRIEVAL ALGORITHMS
S =
⎛⎜⎜⎜⎜⎜⎜⎜⎜⎜⎝
P1G1 P1G2 · · · P1GN−1 P1GN
P2G2 P2G3 · · · P2GN P2G1
......
. . ....
...
PN−1GN−1 PN−1GN · · · PN−1GN−3 PN−1GN−2
PNGN PNG1 · · · PNGN−2 PNGN−1
⎞⎟⎟⎟⎟⎟⎟⎟⎟⎟⎠(A.3)
Note how it is possible to obtain O from S and vice versa. S is the direct
matrix representation of the streaking process in the time domain, and has
therefore a straightforward interpretation. O has the key property of having
only one eigenvalue different from zero with only one left and one right eigen-
vector corresponding to P and G. After applying the intensity constraint in
the frequency domain the new matrix O′ is not an outer product matrix, but
the left and right eigenvectors with the highest eigenvalue provide a good ap-
proximation for P and G. A good guess of P and G for the next iteration is
given simply by one iteration of the power method [55]:
P next = (O′O′T )P
Gnext = (O′TO′)G(A.4)
There are two main assumptions or constraints when using the PCGPA
algorithm. First the relation between O and S has physical meaning only if
the gate has periodic boundary conditions. In other words one has to be sure
that shifting the entries of G to obtain a delayed replica of the gate is actually
a good representation of the physical system. This is verified in the case of
streaking with a few cycle pulse that goes to zero at early and late delays.
The second and more stringent assumption for PCGPA is that the axes of
the signal matrix are Fourier conjugate and therefore one has to manipulate
the measured trace so that the maximum energy range measured ΔΩ and the
APPENDIX A. RETRIEVAL ALGORITHMS 189
delay step size δτ are related as
ΔΩ · δτ = 2π (A.5)
This is not usually the case and in most cases interpolation of the mea-
sured trace is necessary before the analysis with PCGPA is possible. Such
manipulation can lead to ambiguities in the retrieved pulses [139].
A.2 LSGPA
The LSGPA [139] differs from the PCGPA in the approach for the prediction
of the next iteration P and G. As the name explains the LSGPA is based on
a least-squares minimisation of a figure of merit in order to find the best P
and G pair. Moreover it decouples the fourier requrements for the two axis of
the signal matrix in the following way:
ΔΩ · δτ = 2π · L (A.6)
This allows the delay step to be L times larger than the one required by
PCGPA. With this new parameter the signal matrix can be written as Sj,i =
PjGj+L(i−1) with j = 1 · · ·N the energy points and i = 1 · · ·Nτ the delay
points. In matrix form S is given by:
S =
⎛⎜⎜⎜⎜⎜⎜⎜⎜⎜⎝
P1G1 P1G1+L · · · P1G1+(Nτ−2)L P1G1+(Nτ−1)L
P2G2 P2G2+L · · · P2G2+(Nτ−2)L P2G2+(Nτ−1)L
......
. . ....
...
PN−1GN−1 PN−1GN−1+L · · · PN−1GN−1+(Nτ−2)L PN−1GN−1+(Nτ−2)L
PNGN PNGN+L · · · PNGN+(Nτ−2)L PNGN+(Nτ−2)L
⎞⎟⎟⎟⎟⎟⎟⎟⎟⎟⎠(A.7)
The figure of merit M used to describe the accuracy of the retrieval is
defined as follow:
190 APPENDIX A. RETRIEVAL ALGORITHMS
M =Nτ∑i=1
N∑j=1
∣∣PjGj+L(i−1) − S ′(j, i)∣∣2 (A.8)
This parameter can be described as the error, in the (t, τ) domain, between
the signal matrix obtained with the measured intensity, and the signal matrix
arising from the pure application of (5.2). When this comparison is performed
in the (ω, τ) domain it is expressed in the form of the FROG error [53]:
εFROG =
√1
Nmatrix
∑∣∣∣∣[S ′(ω, τ)]2
−[S(ω, τ)
]2∣∣∣∣2 (A.9)
This expression corresponds to the rms of the difference between the mea-
sured and retrieved trace intensity. Nmatrix corresponds to N2 in the PCGPA
case where the matrix is square, while it corresponds to NτN in the LSGPA
one.
The least-squares method yields an expression for the pulse and gate of the
next iteration:
Pj =
∑m Sj,mG
∗j+L(m−1)∑
m
∣∣Gj+L(m−1)
∣∣2Gk =
∑n Sk−L(n−1),nP
∗k−L(n−1)∑
n
∣∣Pk−L(n−1)
∣∣2(A.10)
with indexes running according to:
j = 1 · · ·Nk = 1 · · ·N + L(Nτ − 1)
m = max
{1,
⌈R− j + 1
L
⌉+ 1
}· · ·min
{Nτ ,
⌈R− j
L
⌉+Nτ
}n = max
{1,
⌈k −N
L
⌉+ 1
}· · ·min
{Nτ ,
⌈k
L
⌉}(A.11)
The parameter R is required to avoid points at the extrema of the gate axis
to be taken into account and is set to N/2.
APPENDIX A. RETRIEVAL ALGORITHMS 191
It is also possible to estimate the robustness of the retrieval from S ′. Having
the combined information of the temporal and frequency constraints, we can
extrapolate how well they match (or differ) with each other. As proposed in
[82], it is possible to remove the gate action from the pulse information in S ′.
In the case of LSGPA such action is performed by just inverting the definition
of S to obtain P :
Pj,i =Sj,i
Gj+L(i−1)
(A.12)
The result is then a matrix with a collection of pulses, calculated at each
delay. If the temporal and frequency constraints were perfectly matched this
action would be a mathematical inversion, yielding a series of identical pulses.
The discrepancies between the pulses obtained can there fore be considered as
an indication of the error that can be attributed to the retrieved pulse.
193
Appendix B
Copyright permissions
A list of the third party copyrighted works republished in this thesis is provided
in the table below.
Item PageType of
workSource
Copyright holder
and yearPermission
1 47 Figure [58]c©2012 IOP
Publishing Ltd�
2 62 Figure [77] c©2006 Elsevier B. V. �
375 78
79 80Figure [32]
c©2013 Optical Society
of America�
4 94 Figure [109]c©2010 The American
Physical Society�
5 96 Figure [33]c©2014 AIP
Publishing LLC�
6 101 Figure [17] c©2012 OSA �
7 131 Figure [139]c©The Author(s) 2008,
Springer�
194 APPENDIX B. COPYRIGHT PERMISSIONS
B.1 Item 1
Re: Copyright permission Journal of Physics BZora Catterick [[email protected]] on behalf of Permissions [[email protected]]Sent: 20 March 2015 12:04To: Fabris, DavideAttachments:Copyright_IOP.pdf (206 KB )
Dear Davide Fabris,Thank you for your request to reproduce IOP Publishing material.
Figure 1 J. Phys. B: At. Mol. Opt. Phys. 45 (2012) 074014 to be reused in your thesis.
We are happy to grant permission for the use you request on the terms set out below. ConditionsNon exclusive, non transferrable, revocable, worldwide, permission to use the material in print and electronic formwill be granted subject to the fol lowing conditions:
Permission will be cancelled without notice if you fail to fulfil any of the conditions of this letter. You will make reasonable efforts to contact the author(s) to seek consent for your intended use.
Contacting one author acting expressly as authorised agent for their co authors is acceptable. You will reproduce the following prominently alongside the material:
o the source of the material, including author, article title, title of journal, volume number, issue number(if relevant), page range (or first page if this is the only information available) and date of first publication. Thisinformation can be contained in a footnote or reference note; oro a link back to the article (via DOI); ando if practical and IN ALL CASES for works published under any of the Creative Commons licences thewords “© IOP Publishing. Reproduced by permission of IOP Publishing. All rights reserved”
The material will not, without the express permission of the author(s), be used in any way which, in theopinion of IOP Publishing, could distort or alter the author(s)’ original intention(s) and meaning, be prejudicial tothe honour or reputation of the author(s) and/or imply endorsement by the author(s) and/or IOP Publishing.
Payment of £0 is received in full by IOP Publishing prior to use.If you have any questions, please feel free to contact our Permissions team at [email protected] should be grateful if you would acknowledge receipt of this email.Kind regards,Zora CatterickPublishing AssistantIOP PublishingPlease note: We do not usually provide signed permission forms as a separate attachment. Please print thisemail and provide it to your publisher as proof of permission.
APPENDIX B. COPYRIGHT PERMISSIONS 195
B.2 Item 2
Title: Tracking individual electrontrajectories in a high harmonicspectrum
Author: L.E. Chipperfield,P.L.Knight,J.W.G. Tisch,J.P. Marangos
Publication: Optics CommunicationsPublisher: ElsevierDate: Aug 15, 2006Copyright © 2006, Elsevier
Logged in as: Davide Fabris Account #: 3000900892
Order Completed
Thank you for your order.
This Agreement between ("You") and Elsevier ("Elsevier") consists of your order details and the termsand conditions provided by Elsevier and Copyright Clearance Center.
License number Reference confirmation email for license number License date Mar 20, 2015 Licensed contentpublisher
Elsevier
Licensed contentpublication
Optics Communications
Licensed content title Tracking individual electron trajectories in a high harmonic spectrum Licensed content author L.E. Chipperfield,P.L. Knight,J.W.G. Tisch,J.P. Marangos Licensed content date 15 August 2006 Licensed content volumenumber
264
Licensed content issuenumber
2
Number of pages 8 Type of Use reuse in a thesis/dissertation Portion figures/tables/illustrations Number offigures/tables/illustrations
1
Format both print and electronic Are you the author of thisElsevier article?
No
Will you be translating? No Original figure numbers figure 5 Title of yourthesis/dissertation
Sources and methods for attosecond pump-probe experiments
Expected completion date Mar 2015 Elsevier VAT number GB 494 6272 12 Billing Type Invoice Billing address Davide Fabris
Prince Consort RdBlackett LaboratoryImperial College LondonLondon, United Kingdom SW7 2BWAttn: Davide Fabris
Permissions price 0.00 GBP VAT/Local Sales Tax 0.00 GBP / 0.00 GBP Total 0.00 GBP
Copyright © 2015 Copyright Clearance Center, Inc. All Rights Reserved. Privacy statement. Terms and Conditions. Comments? We would like to hear from you. E-mail us at [email protected]
196 APPENDIX B. COPYRIGHT PERMISSIONS
B.3 Item 3
RE: Copyright permission Optics Letterspubscopyright [[email protected]]Sent: 30 March 2015 15:43To: Fabris, DavideAttachments:OSA Copyright Transfer For~1.pdf (49 KB)
Dear Mr. Fabris, You have permission to include your paper in your thesis. Attached is information which should answer yourother questions. Please contact me with any additional inquiries. Sincerely, Susannah LehmanOSA From: Davide Fabris [mailto:[email protected]] Sent: Friday, March 20, 2015 4:35 AMTo: pubscopyrightSubject: Copyright permission Optics Letters To whom it may concern, attached you find the request of permission to reproduce some material on my PhD thesis. Please let me know if you need any further information. Best regards, Davide Fabris
APPENDIX B. COPYRIGHT PERMISSIONS 197
B.4 Item 4
American Physical Society License Details
Mar 20, 2015
This is an Agreement between Davide Fabris ("You") and American Physical Society ("Publisher"). Itconsists of your order details, the terms and conditions provided by American Physical Society, andthe payment instructions.License Number 3592971493691
License date Mar 20, 2015
Licensed content publisher American Physical Society
Licensed content publication Physical Review Letters
Licensed content title Role of Autoionizing State in Resonant High Order HarmonicGeneration and Attosecond Pulse Production
Licensed copyright line Copyright © 2010, American Physical Society
Licensed content author V. Strelkov
Licensed content date Mar 22, 2010
Volume number 104
Type of Use Thesis/Dissertation
Requestor type Student
Format Print, Electronic
Portion chart/graph/table/figure
Number ofcharts/graphs/tables/figures
1
Portion description Figure 1
Rights for Main product
Duration of use Life of current edition
Creation of copies for thedisabled
no
With minor editing privileges no
For distribution to Worldwide
In the following language(s) Original language of publication
With incidental promotionaluse
no
The lifetime unit quantity ofnew product
0 to 499
The requestingperson/organization is:
Davide Fabris / Imperial College London
Order reference number None
Title of your thesis /dissertation
Sources and methods for attosecond pump probe experiments
Expected completion date Mar 2015
Expected size (number ofpages)
200
Total 0.00 GBP
Terms and Conditions
198 APPENDIX B. COPYRIGHT PERMISSIONS
B.5 Item 5
AIP PUBLISHING LLC LICENSETERMS AND CONDITIONS
Mar 23, 2015All payments must be made in full to CCC. For payment instructions, please seeinformation listed at the bottom of this form.
License Number 3594700086166
Order Date Mar 23, 2015
Publisher AIP Publishing LLC
Publication Applied Physics Letters
Article Title Spatial coherence measurements of non resonant and resonant highharmonics generated in laser ablation plumes
Author R. A. Ganeev,Z. Abdelrahman,F. Frank, et al.
Online Publication Date Jan 17, 2014
Volume number 104
Issue number 2
Type of Use Thesis/Dissertation
Requestor type Author (original article)
Format Print and electronic
Portion Figure/Table
Number of figures/tables 4
Title of your thesis /dissertation
Sources and methods for attosecond pump probe experiments
Expected completion date Mar 2015
Estimated size (number ofpages)
200
Total 0.00 GBP
Terms and Conditions
APPENDIX B. COPYRIGHT PERMISSIONS 199
B.6 Item 6
RE: Copyright permission Optics Expresspubscopyright [[email protected]]Sent:31 March 2015 17:50To: Fabris, Davide
Sorry, yes you have permission to reproduce Fig 6. From: Davide Fabris [mailto:[email protected]] Sent: Monday, March 30, 2015 10:59 AMTo: pubscopyrightSubject: Re: Copyright permission Optics Express Dear Susannah Lehman, thanks for your reply, however while for the Optics Letters paper (Okell et al) I am a co-author, I amnot an author for the Optics Express paper (Miranda et al.) Of the Optics Express paper I wish toreproduce portion of figure 6 in my PhD thesis. Do I have permission to do so? Best regards, Davide Fabris On 30 March 2015 at 16:42, pubscopyright <[email protected]> wrote:Dear Mr. Fabris, You have permission to include your paper in your thesis. Attached is information which should answer yourother questions. Please contact me with any additional inquiries. Sincerely, Susannah LehmanOSA From: Davide Fabris [mailto:[email protected]] Sent: Friday, March 20, 2015 4:35 AMTo: pubscopyrightSubject: Copyright permission Optics Express To whom it may concern, attached you find the request of permission to reproduce some material on my PhD thesis. Please let me know if you need any further information. Best regards, Davide Fabris
200 APPENDIX B. COPYRIGHT PERMISSIONS
B.7 Item 7
I would like to include the extract in the printed examination copy of my thesis andalso the electronic version which will be added to Spiral, Imperial’s online repositoryhttp://spiral.imperial.ac.uk/ and made available to the public under a CreativeCommons Attribution-NonCommercial-NoDerivs licence
19/03/2015
Dear Dr. Justin Gagnon
I am completing my PhD thesis at Imperial College London entitled ‘methods for attosecond pump-probe experiments’.
I seek your permission to reprint, in my thesis an extract from:
J. Gagnon, E. Goulielmakis, and V. S. Yakovlev. “The accurate FROG characterization ofattosecond pulses from streaking measurements”. In: Applied Physics B 92.1 (July 2008), pp.25–32.
The extract to be reproduced is: adaptation of Figure 1
Ultrafast lightsources and
APPENDIX B. COPYRIGHT PERMISSIONS 201
01_02 PERMISSION LETTER
March 20, 2015 Springer reference Applied Physics B July 2008, Volume 92, Issue 1, pp 25-32, Open Access Date: 10 Jun 2008 The accurate FROG characterization of attosecond pulses from streaking measurements © The Author(s) 2008 J. Gagnon, E. Goulielmakis, V.S. Yakovlev DOI 10.1007/s00340-008-3063-x Print ISSN 0946-2171 Online ISSN 1432-0649 Journal number: 00340 Material to be used: Figure 1 Your project Requestor: Davide Fabris
[email protected] University: Imperial College London Purpose: Dissertation/Thesis With reference to your request to reuse material in which Springer Science+Business Media controls the copyright, our permission is granted free of charge under the following conditions: Springer material
represents original material which does not carry references to other sources (if material in question refers with a credit to another source, authorization from that source is required as well);
requires full credit (Springer and the original publisher, book/journal title, chapter/article title, volume, year of publication, page, name(s) of author(s), original copyright notice) to the publication in which the material was originally published by adding: "With kind permission of Springer Science+Business Media";
figures, illustrations, and tables may be altered minimally to serve your work. Any other abbreviations, additions, deletions and/or any other alterations shall be made only with prior written authorization of the author and/or Springer Science+Business Media;
Springer does not supply original artwork or content.
This permission is non-exclusive; is valid for one-time use only for the purpose of defending your thesis limited to university-use only and with a maximum of 100 extra copies in paper. If the thesis is going to be published, permission needs to be reobtained.
includes use in an electronic form, provided it is an author-created version of the thesis on his/her own website and his/her university’s repository, including UMI (according to the definition on the Sherpa website: http://www.sherpa.ac.uk/romeo/);
is subject to courtesy information to the author (address is given in the publication); is personal to you and may not be sublicensed, assigned, or transferred by you to any other person without Springer's written permission;
is only valid if no personal rights, trademarks, or competitive products are infringed.