UH209 Series Filters - Industrial Manufacturing · UH209 Series Filters Ordering Information Table...
-
Upload
nguyenkien -
Category
Documents
-
view
217 -
download
0
Transcript of UH209 Series Filters - Industrial Manufacturing · UH209 Series Filters Ordering Information Table...
IMUH209ENe
UH209 Series Filters
UH209
ULTIPLEAT® SRT HIGH PRESSURE FILTERS
Port Size ¾" and 1"
UH209HIGH PRESSURE FILTERS
UH209 Series Filters
Technical Information
Features• Patented Ultipleat (laid-over pleat)
filter medium pack• Coreless, cageless element
configuration• Pall Stress-Resistant Technology
(SRT) Media• In-to-out filter element flow path• Flows to 110 L/min (30 US gpm)• Pressures to 350 bar (5075 psi)• Port size ¾" and 1"
Notes and SpecificationsFilter Housing• Maximum Working Pressure:
350 bar (5075 psi)• Rated Fatigue Pressure:
0-300 bar (4350 psi) per NFPAT2.06.01R2-2001 CAT C/90/*(1 million cycles), verified bytesting at 0-353 bar (5120 psi) for 1 million cycles. Contact Pall for applications with higher pressures at lower cycles
• Typical Burst Pressure:1050 bar (15,225 psi)
• Fluid Compatibility:Compatible with all petroleum oils, waterglycols, water-oil emulsions and mostsynthetic hydraulic and lubrication fluids
• Temperature Range:Fluorocarbon Seals: -29 ˚C to 120 ˚C (-20 ˚F to 250 ˚F) 60 ˚C (140 ˚F) maximum in HWCF or water glycol fluids
• Bypass Valve Setting:4.5 bard (65 psid)
• Indicator Pressure Setting:3.5 bard (50 psid)
• Materials of Construction:Head: Ductile Cast IronTube: Carbon steel
Filter Element• Filter Element Burst Pressure:
10 bard (150 psid)• Ultipleat SRT Element Construction:
Inorganic fibers impregnated andbonded with epoxy resins. Polymerendcaps. Anti-static media design
The equipment has been assessed in accordance with the guidelines laid down in The EuropeanPressure Directive 97/23/EC and has been classifiedwithin Sound Engineering Practice S.E.P. Suitable foruse with Group 2 fluids only. Consult Sales for otherfluid gas group suitability.
0
5
10
15
Flow (US gpm)
0 5 10 20 25
ΔP
(psi
d)
20
3015
0 20 40 80 100 11060
0
0.5
1.0
1.5
ΔP
(bar
d)
Flow (L/min)
-12 Ports
-16 Ports
Element Pressure Drop Multiply actual flow rate times factor in table below to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for otherfluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9.Note: factors are per 1000 L/min and per 1 US gpm.
209 Series Filter Elements — bard/1000 L/min (psid/US gpm)
Length Code AZ AP AN AS AT
03 34.75 (1.904) 13.92 (0.763) 10.62 (0.582) 9.00 (0.493) 7.67 (0.420)07 15.69 (0.860) 6.29 (0.345) 4.79 (0.262) 4.06 (0.222) 3.46 (0.190)
Pressure Drop Information
Housing pressure drop using fluid with 0.9 S.G. Housing pressure drop is directly proportional to specific gravity.
Sample ΔP calculation
UH20 9 Series 7" length housing with C16 (1" BSP) threaded ports using AN grade media. Operating conditions 50 L/min flow rate using a hydraulic fluid of 50 cSt and specific gravity (s.g.) 1.2.
Total Filter ΔP= ΔP housing + ΔP element
= (0.2 x 1.2/0.9) bard (housing)
+ ((50 x 4.79/1000) x 50/32 x 1.2/0.9) bard element)
= 0.24 bard (housing) + 0.50 bard (element)
= 0.74 bard (11.2 psid)
UH209 Series Filters
Ordering Information
Table 1: Housing Port OptionsCode PortA12 ¾" SAE J514 straight threadA16 1" SAE J514 straight threadC12 ¾" BSP ISO 228 threadsC16 1" BSP ISO 228 threads
Element P/N: UE 209 Z
Housing P/N: UH 209 H ++ Z G 1Table 1 Table 2
Table 1 Table 2
Seal Kit P/N: UH 209 SKZ
Table 2: Housing Length OptionsCode Length (in)*03 307 7
* Nominal length
Table 1: Filter Element OptionsCode ßx(c) ≥1000 CST Rating*
based on ISO 16889
AZ 3 08/04/01AP 5 12/07/02AN 7 15/11/04AS 12 16/13/04AT 22 17/15/08
*Other seal material options are available; Contact Pall.
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall. The suffix ‘1’ at the end of the Housing P/N designates an indicator port,fitted with a plastic shipping plug.
Table 3: ‘M’ & ‘R’-Type Indicator Codes*
Code OptionYM ‘M’ optionYR ‘R’ option
* Use only if ‘R’ or ‘M’ Indicator is selected from Table 1
* CST: Cyclic Stabilization Test to determine filter rating under stress conditions, based on SAE ARP4205
Note: Pall Ultipleat SRT filter housings are supplied without filter elements or warning devices fitted. Never operate the filter unless a filter element is fitted and all warning device ports are sealed.
Differential Pressure Indicator P/N: RC 091 Z Table 1 Table 2 Table 3
Table 1: Differential Pressure Indicator Options*Code Indicator ‘H’ Dim.778NZ ‘P’ type Visual indicator with thermal lockout 21mm (0.83in)860MZ ‘D’ type Visual indicator with no thermal lockout 21mm (0.83in)861CZ ‘L’ type Electrical switch (SPDT) with 6" leads 38mm (1.50in)861CZ ‘M’ type Electrical switch (SPDT) with 78mm (3.07in)
DIN43650 connector and matching cap861CZ ‘R’ type Electrical switch (SPDT) and neon light 89mm (3.50in)
indicator with DIN43650 connector and cap771BZ ‘S’ type Electrical switch (SPDT) with 3-pin 57mm (2.24in)
MS connector
* Other options available on application.
Table 2: Differential Pressure Indicator MaterialCode Pressure SettingOmit Aluminium Alloy Indicator: use at operating pressures < 200 bard (3000 psid)SS Stainless Steel Indicator: use at operating pressures > 200 bard (3000 psid)
* Other setting options are available; contact Pall.
For new installations, select one complete part number from each section below
Section 1
Section 2
Section 3
Table 4
Table 4: ‘R’ Indicator OptionsCode Option110AC 110V AC220AC 220V AC24DC 24V DC
* Use only if ‘R’Indicator is selected from Table 1
Table 2: Filter Element Length OptionsCode Length (in)*03 307 7
* Nominal length
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.
UH209HIGH PRESSURE FILTERS
UH209 Series Filters
Technical Information
DIM
'H'
23.2
mm
0.91
3 in
46.5
5 m
m1.
833
in
48.5
mm
1.90
9 in
44.5
mm
1.75
in
29.4 mm1.157 in
58.8 mm2.315 in
to BS3643 for 'C' PortsM8-1.25-6H
See
Tab
le 1
Torque setting 54Nm
5/16" UNC 2B to BS1580 For 'A' Ports
Ø 65 mm PCDØ 2.56 in
12 Min full threadMounting Holes 3 Positions
60 m
m2.
4 in
52.5 mm2.07 in
52.5 mm2.07 in
110
mm
4.3
3 in
Ove
rall
Leng
th
78.5
mm
3.0
9 in
89 mm3.50 in
70 mm2.756 in
Section View B-B
Bypass Valve
Inlet Outlet
Torqueto 100 Nm
Min
req
uire
d
dis
tanc
e to
rem
ove
bow
lan
d e
lem
ent
Element Overall Removal Empty
Length Length Clearance WeightCode mm (in) mm (in) kg (lb)
03 225 (8.9) 60 (2.4) 5.3 (11.7)
07 316 (12.4) 60 (2.4) 6.3 (13.9)
Pall Industrial Manufacturing
25 Harbor Park DrivePort Washington, NY 11050 +1 516 484 3600 telephone+1 800 289 7255 toll free US
Portsmouth-UK+44 (0)23 9230 3303 telephone+44 (0)23 9230 2507 fax
Visit us on the Web at www.pall.com
Pall Corporation has offices and plants throughout the world. For Pall representativesin your area, please go to www.pall.com/contact
Because of technological developments related to the products, systems, and/orservices described herein, the data and procedures are subject to change withoutnotice. Please consult your Pall representative or visit www.pall.com to verify thatthis information remains valid. Products in this document may be covered by oneor more of the following patent numbers: EP 667,800; EP 982,061; EP 1,380,331;EP 1 656 193; US 5,543,047; US 5,690,765; US 5,725,784; US 6,113,784; US 7,083,564; US 7,318,800.
© Copyright 2009, Pall Corporation. Pall, , and Ultipleat are trademarks of Pall Corporation. ® Indicates a trademark registered in the USA. Filtration. Separation. Solution.SM is a service markof Pall Corporation.
IMUH209ENe Printed in the UK. July 2009