![Page 1: UCSF Osher Mini-Medical School for the PublicMatthew Garibaldi, MS, CPO Director Assistant Clinical Professor Richard Nguyen, CPO Clinical Chief Advances in Prosthetic Technology UCSF](https://reader033.fdocuments.us/reader033/viewer/2022041507/5e25f860887a3d0e1c5d694c/html5/thumbnails/1.jpg)
1 | [footer text here]
2/22/2018
Matthew Garibaldi, MS, CPODirector
Assistant Clinical ProfessorRichard Nguyen, CPO
Clinical Chief
Advances in Prosthetic TechnologyUCSF Osher Mini-Medical School for the Public
“
Presentation Title2
Any sufficiently advanced technology is indistinguishable from magic.
Arthur C. Clarke
Advances in Prosthetic Technology3
What is a Prosthesis?
Definition: an artificial device to replace or augment a missing or impaired part of the body
![Page 2: UCSF Osher Mini-Medical School for the PublicMatthew Garibaldi, MS, CPO Director Assistant Clinical Professor Richard Nguyen, CPO Clinical Chief Advances in Prosthetic Technology UCSF](https://reader033.fdocuments.us/reader033/viewer/2022041507/5e25f860887a3d0e1c5d694c/html5/thumbnails/2.jpg)
2 | [footer text here]
Presentation Title4
What is a Prosthesis?Internal vs. External Prosthesis
Presentation Title5
What is a Prosthesis?Restoration vs. Functional
Presentation Title6
What is a Prosthesis?External Functional Device
Prosthesis Orthosis
![Page 3: UCSF Osher Mini-Medical School for the PublicMatthew Garibaldi, MS, CPO Director Assistant Clinical Professor Richard Nguyen, CPO Clinical Chief Advances in Prosthetic Technology UCSF](https://reader033.fdocuments.us/reader033/viewer/2022041507/5e25f860887a3d0e1c5d694c/html5/thumbnails/3.jpg)
3 | [footer text here]
Advances in Prosthetic Technology7
Anatomy of a Prosthesis
-Socket: human interface
What makes up a prosthetic device
Advances in Prosthetic Technology8
Anatomy of a Prosthesis
-Socket: human interface
-Joint Replacement: elbow or knee
What makes up a prosthetic device
Advances in Prosthetic Technology9
Anatomy of a Prosthesis
-Socket: human interface
-Joint Replacement: elbow or knee
-Terminal Device: hand or foot
What makes up a prosthetic device
![Page 4: UCSF Osher Mini-Medical School for the PublicMatthew Garibaldi, MS, CPO Director Assistant Clinical Professor Richard Nguyen, CPO Clinical Chief Advances in Prosthetic Technology UCSF](https://reader033.fdocuments.us/reader033/viewer/2022041507/5e25f860887a3d0e1c5d694c/html5/thumbnails/4.jpg)
4 | [footer text here]
Advances in Prosthetic Technology10
Prosthetic Sockets
Advances in Prosthetic Technology11
Historical Perspective on SocketsCarved Wooden sockets
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology12
Modern Prosthetics
Hand Cast
- Plaster
- Positive model
- Vacuum form
- Test socket
- Final socket
Taking a manual mold of the residual limb
Socket
Joint
Terminal Device
Upper Extremity
![Page 5: UCSF Osher Mini-Medical School for the PublicMatthew Garibaldi, MS, CPO Director Assistant Clinical Professor Richard Nguyen, CPO Clinical Chief Advances in Prosthetic Technology UCSF](https://reader033.fdocuments.us/reader033/viewer/2022041507/5e25f860887a3d0e1c5d694c/html5/thumbnails/5.jpg)
5 | [footer text here]
Advances in Prosthetic Technology13
Modern Prosthetics
Hand Cast
- Plaster
- Positive model
- Vacuum form
- Test socket
- Final socket
Taking a manual mold of the residual limb
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology14
Modern Prosthetics
Hand Cast
- Plaster
- Positive model
- Vacuum form
- Test socket
- Final socket
Taking a manual mold of the residual limb
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology15
Modern Prosthetics
Hand Cast
- Plaster
- Positive model
- Vacuum form
- Test socket
- Final socket
Taking a manual mold of the residual limb
Socket
Joint
Terminal Device
Upper Extremity
![Page 6: UCSF Osher Mini-Medical School for the PublicMatthew Garibaldi, MS, CPO Director Assistant Clinical Professor Richard Nguyen, CPO Clinical Chief Advances in Prosthetic Technology UCSF](https://reader033.fdocuments.us/reader033/viewer/2022041507/5e25f860887a3d0e1c5d694c/html5/thumbnails/6.jpg)
6 | [footer text here]
Advances in Prosthetic Technology16
Modern Prosthetics
Hand Cast
- Plaster
- Positive model
- Vacuum form
- Test socket
- Final socket
Taking a manual mold of the residual limb
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology17
Modern Prosthetics
Digital Scan
- 3D Digital Scan
- 3D CAD model
- Foam carving
- 3D print
Digital mold of the residual limb
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology18
Modern Prosthetics
Digital Scan
- 3D Digital Scan
- 3D CAD model
- Foam carving
- 3D print
Digital mold of the residual limb
Socket
Joint
Terminal Device
Upper Extremity
![Page 7: UCSF Osher Mini-Medical School for the PublicMatthew Garibaldi, MS, CPO Director Assistant Clinical Professor Richard Nguyen, CPO Clinical Chief Advances in Prosthetic Technology UCSF](https://reader033.fdocuments.us/reader033/viewer/2022041507/5e25f860887a3d0e1c5d694c/html5/thumbnails/7.jpg)
7 | [footer text here]
Advances in Prosthetic Technology19
Modern Prosthetics
Digital Scan
- 3D Digital Scan
- 3D CAD model
- Foam carving
- 3D print
Digital mold of the residual limb
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology20
Modern Prosthetics
Digital Scan
- 3D Digital Scan
- 3D CAD model
- Foam carving
- 3D print
Digital mold of the residual limb
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology21
Modern Prosthetics
Transtibial Socket Design
- Paltellar Tendon Bearing
- Total Surface Bearing
- Elevated Vacuum
- Adjustable
Socket Technology
Socket
Joint
Terminal Device
Upper Extremity
![Page 8: UCSF Osher Mini-Medical School for the PublicMatthew Garibaldi, MS, CPO Director Assistant Clinical Professor Richard Nguyen, CPO Clinical Chief Advances in Prosthetic Technology UCSF](https://reader033.fdocuments.us/reader033/viewer/2022041507/5e25f860887a3d0e1c5d694c/html5/thumbnails/8.jpg)
8 | [footer text here]
Advances in Prosthetic Technology22
Modern Prosthetics
Transtibial Socket Design
- PTB
- Total Surface Bearing
- Elevated Vacuum
- Adjustable
Socket Technology
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology23
Modern Prosthetics
Transtibial Socket Design
- PTB
- Total Surface Bearing
- Elevated Vacuum
- Adjustable
Socket Technology
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology24
Modern Prosthetics
Transtibial Socket Design
- PTB
- Total Surface Bearing
- Elevated Vacuum
- Adjustable
Socket Technology
Socket
Joint
Terminal Device
Upper Extremity
![Page 9: UCSF Osher Mini-Medical School for the PublicMatthew Garibaldi, MS, CPO Director Assistant Clinical Professor Richard Nguyen, CPO Clinical Chief Advances in Prosthetic Technology UCSF](https://reader033.fdocuments.us/reader033/viewer/2022041507/5e25f860887a3d0e1c5d694c/html5/thumbnails/9.jpg)
9 | [footer text here]
Advances in Prosthetic Technology25
Modern Prosthetics
Transfemoral Socket Design
- Quad
- Ischial Containment
- VECTR
Socket Technology
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology26
Modern Prosthetics
Transfemoral Socket Design
- Quad
- Ischial Containment
- VECTR
Socket Technology
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology27
Modern Prosthetics
Transfemoral Socket Design
- Quad
- Ischial Containment
- VECTR
Socket Technology
Socket
Joint
Terminal Device
Upper Extremity
![Page 10: UCSF Osher Mini-Medical School for the PublicMatthew Garibaldi, MS, CPO Director Assistant Clinical Professor Richard Nguyen, CPO Clinical Chief Advances in Prosthetic Technology UCSF](https://reader033.fdocuments.us/reader033/viewer/2022041507/5e25f860887a3d0e1c5d694c/html5/thumbnails/10.jpg)
10 | [footer text here]
Advances in Prosthetic Technology28
Modern Prosthetics
Transfemoral Socket Design
- Quad
- Ischial Containment
- VECTR
Socket Technology
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology29
Future Prosthetics Eliminating the socket
Socket
Joint
Terminal Device
Upper Extremity
Osseo Integration - OPRA
- Fixture
- Abutment
- Axor II
Advances in Prosthetic Technology30
Future Prosthetics Eliminating the socket
Socket
Joint
Terminal Device
Upper Extremity
Osseo Integration - OPRA
- Fixture
- Abutment
- Axor II
![Page 11: UCSF Osher Mini-Medical School for the PublicMatthew Garibaldi, MS, CPO Director Assistant Clinical Professor Richard Nguyen, CPO Clinical Chief Advances in Prosthetic Technology UCSF](https://reader033.fdocuments.us/reader033/viewer/2022041507/5e25f860887a3d0e1c5d694c/html5/thumbnails/11.jpg)
11 | [footer text here]
Advances in Prosthetic Technology31
Future Prosthetics Eliminating the socket
Osseo Integration - OPRA
- Fixture
- Abutment
- Axor II
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology32
Future ProstheticsEliminating the socket
Socket
Joint
Terminal Device
Upper Extremity
Osseo Integration - OPRA
- Fixture
- Abutment
- Axor II
Advances in Prosthetic Technology33
Future ProstheticsEliminating the socket
Socket
Joint
Terminal Device
Upper Extremity
![Page 12: UCSF Osher Mini-Medical School for the PublicMatthew Garibaldi, MS, CPO Director Assistant Clinical Professor Richard Nguyen, CPO Clinical Chief Advances in Prosthetic Technology UCSF](https://reader033.fdocuments.us/reader033/viewer/2022041507/5e25f860887a3d0e1c5d694c/html5/thumbnails/12.jpg)
12 | [footer text here]
Advances in Prosthetic Technology34
Prosthetic Knees
Advances in Prosthetic Technology35
Historical Perspective
Mid – late 1500s
- Ambroise Pare
-French army barber/surgeon
-Father of modern amputation surgery
-Introduced modern amputation procedures
-Created ground breaking above-knee devices such as a locking knee joints for stability during stance.
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology36
Modern Prosthetics
Knees
- Mechanical
- Hydraulic
- Microprocessor Controlled
- Powered
Knee Joint Technology
Socket
Joint
Terminal Device
Upper Extremity
![Page 13: UCSF Osher Mini-Medical School for the PublicMatthew Garibaldi, MS, CPO Director Assistant Clinical Professor Richard Nguyen, CPO Clinical Chief Advances in Prosthetic Technology UCSF](https://reader033.fdocuments.us/reader033/viewer/2022041507/5e25f860887a3d0e1c5d694c/html5/thumbnails/13.jpg)
13 | [footer text here]
Advances in Prosthetic Technology37
Modern Prosthetics
Knees
- Mechanical
- Hydraulic
- Microprocessor Controlled
- Powered
Knee Joint Technology
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology38
Modern Prosthetics
Knees
- Mechanical
- Hydraulic
- Microprocessor Controlled
- Powered
Knee Joint Technology
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology39
Modern Prosthetics
Knees
- Mechanical
- Hydraulic
- Microprocessor Controlled
- Powered
Knee Joint Technology
Socket
Joint
Terminal Device
Upper Extremity
![Page 14: UCSF Osher Mini-Medical School for the PublicMatthew Garibaldi, MS, CPO Director Assistant Clinical Professor Richard Nguyen, CPO Clinical Chief Advances in Prosthetic Technology UCSF](https://reader033.fdocuments.us/reader033/viewer/2022041507/5e25f860887a3d0e1c5d694c/html5/thumbnails/14.jpg)
14 | [footer text here]
Advances in Prosthetic Technology40
Modern Prosthetics
Knees
- Mechanical
- Hydraulic
- Microprocessor Controlled
- Powered
Knee Joint Technology
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology41
Future Prosthetics
Future Technology
- Bionic Powered Knee/Foot
Knee Joint Technology
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology42
Prosthetic Feet
![Page 15: UCSF Osher Mini-Medical School for the PublicMatthew Garibaldi, MS, CPO Director Assistant Clinical Professor Richard Nguyen, CPO Clinical Chief Advances in Prosthetic Technology UCSF](https://reader033.fdocuments.us/reader033/viewer/2022041507/5e25f860887a3d0e1c5d694c/html5/thumbnails/15.jpg)
15 | [footer text here]
Advances in Prosthetic Technology43
Historical Perspective
17th – 19th Century
- 1858, Douglas Bly
- “Dr. Bly’s Anatomical Leg”
- Ankle joint formed by ivory ball
- Vulcanized rubber foot
- Revered as most complete and success invention ever attained in artificial limbs
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology44
Modern Prosthetics
Feet
- Conventional feet (CF)
- Energy-Storage-and-Return (ESR)
- Articulated Feet
- Dynamic Response
- Microprocessor Controlled Feet
- Bionic feet
Prosthetic Foot Technology
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology45
Modern ProstheticsProsthetic Foot Technology
Socket
Joint
Terminal Device
Upper Extremity
Feet
- Conventional feet (CF)
- Energy-Storage-and-Return (ESR)
- Articulated Feet
- Dynamic Response
- Microprocessor Controlled Feet
- Bionic feet
![Page 16: UCSF Osher Mini-Medical School for the PublicMatthew Garibaldi, MS, CPO Director Assistant Clinical Professor Richard Nguyen, CPO Clinical Chief Advances in Prosthetic Technology UCSF](https://reader033.fdocuments.us/reader033/viewer/2022041507/5e25f860887a3d0e1c5d694c/html5/thumbnails/16.jpg)
16 | [footer text here]
Advances in Prosthetic Technology46
Modern ProstheticsProsthetic Foot Technology
Socket
Joint
Terminal Device
Upper Extremity
Feet
- Conventional feet (CF)
- Energy-Storage-and-Return (ESR)
- Articulated Feet
- Dynamic Response
- Microprocessor Controlled Feet
- Bionic feet
Advances in Prosthetic Technology47
Modern ProstheticsProsthetic Foot Technology
Socket
Joint
Terminal Device
Upper Extremity
Feet
- Conventional feet (CF)
- Energy-Storage-and-Return (ESR)
- Articulated Feet
- Dynamic Response
- Microprocessor Controlled Feet
- Bionic feet
Advances in Prosthetic Technology48
Modern ProstheticsProsthetic Foot Technology
Socket
Joint
Terminal Device
Upper Extremity
Feet
- Conventional feet (CF)
- Energy-Storage-and-Return (ESR)
- Articulated Feet
- Dynamic Response
- Microprocessor Controlled Feet
- Bionic feet
![Page 17: UCSF Osher Mini-Medical School for the PublicMatthew Garibaldi, MS, CPO Director Assistant Clinical Professor Richard Nguyen, CPO Clinical Chief Advances in Prosthetic Technology UCSF](https://reader033.fdocuments.us/reader033/viewer/2022041507/5e25f860887a3d0e1c5d694c/html5/thumbnails/17.jpg)
17 | [footer text here]
Advances in Prosthetic Technology49
Modern ProstheticsProsthetic Foot Technology
Socket
Joint
Terminal Device
Upper Extremity
Feet
- Conventional feet (CF)
- Energy-Storage-and-Return (ESR)
- Articulated Feet
- Dynamic Response
- Microprocessor Controlled Feet
- Bionic feet
Advances in Prosthetic Technology50
Upper Extremity Prosthetics
Advances in Prosthetic Technology51
Historical Perspective
Early 1500s
- Gotz Von Berlichingen
- German engineering
- Articulated hands
- Mechanical masterpieces
Socket
Joint
Terminal Device
Upper Extremity
![Page 18: UCSF Osher Mini-Medical School for the PublicMatthew Garibaldi, MS, CPO Director Assistant Clinical Professor Richard Nguyen, CPO Clinical Chief Advances in Prosthetic Technology UCSF](https://reader033.fdocuments.us/reader033/viewer/2022041507/5e25f860887a3d0e1c5d694c/html5/thumbnails/18.jpg)
18 | [footer text here]
Advances in Prosthetic Technology52
Historical Perspective
World War II
- 1929 – 1945
- U.S. Gov. brokered deal with military companies to improve prosthetic function
- Marked the beginning of the era of modern prosthetics
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology53
Modern Prosthetics
Upper Extremity
- Passive
- Body power
- Electric vs DME (proportional)
- Sequential vs simultaneous
- Multi-articulating digits
- TMR
- DARPA
Upper Extremity Devices
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology54
Modern Prosthetics
Upper Extremity
- Passive
- Body power
- Electric vs DME (proportional)
- Sequential vs simultaneous
- Multi-articulating digits
- TMR
- DARPA
Upper Extremity Devices
Socket
Joint
Terminal Device
Upper Extremity
![Page 19: UCSF Osher Mini-Medical School for the PublicMatthew Garibaldi, MS, CPO Director Assistant Clinical Professor Richard Nguyen, CPO Clinical Chief Advances in Prosthetic Technology UCSF](https://reader033.fdocuments.us/reader033/viewer/2022041507/5e25f860887a3d0e1c5d694c/html5/thumbnails/19.jpg)
19 | [footer text here]
Advances in Prosthetic Technology55
Modern Prosthetics
Upper Extremity
- Passive
- Body power
- Electric & DME (proportional)
- Sequential vs simultaneous
- Multi-articulating digits
- TMR
- DARPA
Upper Extremity Devices
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology56
Modern Prosthetics
Upper Extremity
- Passive
- Body power
- Electric & DME (proportional)
- Sequential vs simultaneous
- Multi-articulating digits
- TMR
- DARPA
Upper Extremity Devices
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology57
Modern Prosthetics
Upper Extremity
- Body power vs external
- Electric vs DME (proportional)
- Sequential vs simultaneous
- Multi-articulating digits
- TMR
- DARPA
Upper Extremity Devices
Socket
Joint
Terminal Device
Upper Extremity
![Page 20: UCSF Osher Mini-Medical School for the PublicMatthew Garibaldi, MS, CPO Director Assistant Clinical Professor Richard Nguyen, CPO Clinical Chief Advances in Prosthetic Technology UCSF](https://reader033.fdocuments.us/reader033/viewer/2022041507/5e25f860887a3d0e1c5d694c/html5/thumbnails/20.jpg)
20 | [footer text here]
Advances in Prosthetic Technology58
Modern Prosthetics
Upper Extremity
- Body power vs external
- Electric vs DME (proportional)
- Sequential vs simultaneous
- Multi-articulating digits
- TMR
- DARPA
Upper Extremity Devices
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology59
Modern Prosthetics
Upper Extremity
- Body power vs external
- Electric vs DME (proportional)
- Sequential vs simultaneous
- Multi-articulating digits
- TMR
- DARPA
Upper Extremity Devices
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology60
Modern Prosthetics
Upper Extremity
- Body power vs external
- Electric vs DME (proportional)
- Sequential vs simultaneous
- Multi-articulating digits
- TMR
- DARPA
Upper Extremity Devices
Socket
Joint
Terminal Device
Upper Extremity
![Page 21: UCSF Osher Mini-Medical School for the PublicMatthew Garibaldi, MS, CPO Director Assistant Clinical Professor Richard Nguyen, CPO Clinical Chief Advances in Prosthetic Technology UCSF](https://reader033.fdocuments.us/reader033/viewer/2022041507/5e25f860887a3d0e1c5d694c/html5/thumbnails/21.jpg)
21 | [footer text here]
Advances in Prosthetic Technology61
Future Prosthetics
Upper Extremity
- Neural Integration
- Sensing Prosthetic Hand
Upper Extremity Devices
Socket
Joint
Terminal Device
Upper Extremity
Advances in Prosthetic Technology62
Future Prosthetics
Upper Extremity
- Neural Integration
- Sensing Prosthetic Hand
Upper Extremity Devices
Socket
Joint
Terminal Device
Upper Extremity