UCS 500N5T SERIES - GOmeasuregomeasure.dk/wp-content/uploads/2017/02/UCS500N5T.pdf · range the...

9
DATA SHEET > UCS 500N5T > 20151007 UCS 500N5T SERIES MULTIFUNCTIONAL TESTGENERATOR FOR CONDUCTED TRANSIENTS (EFT/BURST, SURGE, TELECOM-SURGE & POWER FAIL) UP TO 5.5KV FOR TESTS ACCORDING TO ... > EN 300329 > EN 300340 > EN 300342-1 > EN 300386 V1.3.2 > EN 301489-1 > EN 301489-17 > EN 301489-24 > EN 301489-7 > EN 50121 > EN 55024 > EN 61000-4-11 > EN 61000-4-29 > EN 61000-4-4 > EN 61000-4-5 > EN 61000-4-8 > EN 61000-4-9 > EN 61000-6-1 > EN 61000-6-2 > FCC 97-270 (part 68) > IEC 60255-22-5 > IEC 61000-4-11 > ... UCS 500N5T SERIES - COMPACT TESTER FOR EFT/BURST, SURGE, TELECOM-SURGE AND POWER FAIL The UCS 500N5T Series ultra-compact simulator is the most versatile tester to cover transient and power fail requirements according to international standards (basic and generic standards) and product/product family standards. The UCS 500N5T Series is the most economic solution for tests during development as well as for full-compliant immunity tests and CE Marking for single phase DUT with the ability to be extended for testing three-phase DUTs by means of an automatically controlled external coupling network up to 200 A. EM TEST supplies a large range of accessories for the various applications such as magnetic field tests. HIGHLIGHTS > Burst module IEC/EN 61000-4-4 (up to 5.5 kV) > Surge module IEC/EN 61000-4-5/-9 (up to 5 kV) > TSurge module IEC/EN 61000-4-5 up (to 5 kV) > PowerFail module IEC/EN 61000-4-8/-11/-29 (DC) > Built-in single phase coupler 300 V/16 A > Manual operation from front panel > USB and GPIB-Bus for remote control APPLICATION AREAS INDUSTRY MEDICAL RESIDENTIAL TELECOM COMPONENTS BROADCAST RENEWABLE ENERGY www.emtest.com © EM TEST > PAGE 1/9

Transcript of UCS 500N5T SERIES - GOmeasuregomeasure.dk/wp-content/uploads/2017/02/UCS500N5T.pdf · range the...

Page 1: UCS 500N5T SERIES - GOmeasuregomeasure.dk/wp-content/uploads/2017/02/UCS500N5T.pdf · range the current transformer MC 2630 is used while high-field strength above 100 A/m requires

DATA SHEET > UCS 500N5T > 20151007

UCS 500N5T SERIESMULTIFUNCTIONAL TESTGENERATOR FOR CONDUCTEDTRANSIENTS (EFT/BURST, SURGE, TELECOM-SURGE & POWERFAIL) UP TO 5.5KV FOR TESTS ACCORDING TO ...

> EN 300329> EN 300340> EN 300342-1> EN 300386 V1.3.2> EN 301489-1> EN 301489-17> EN 301489-24> EN 301489-7> EN 50121> EN 55024> EN 61000-4-11> EN 61000-4-29> EN 61000-4-4> EN 61000-4-5> EN 61000-4-8> EN 61000-4-9> EN 61000-6-1> EN 61000-6-2> FCC 97-270 (part 68)> IEC 60255-22-5> IEC 61000-4-11> ...

UCS 500N5T SERIES - COMPACT TESTER FOR EFT/BURST, SURGE, TELECOM-SURGE AND POWER FAIL

The UCS 500N5T Series ultra-compact simulator is the most versatile tester to cover transient and power fail requirementsaccording to international standards (basic and generic standards) and product/product family standards. The UCS 500N5TSeries is the most economic solution for tests during development as well as for full-compliant immunity tests and CEMarking for single phase DUT with the ability to be extended for testing three-phase DUTs by means of an automaticallycontrolled external coupling network up to 200 A.EM TEST supplies a large range of accessories for the various applications such as magnetic field tests.

HIGHLIGHTS

> Burst module IEC/EN 61000-4-4 (up to 5.5 kV)

> Surge module IEC/EN 61000-4-5/-9 (up to 5 kV)

> TSurge module IEC/EN 61000-4-5 up (to 5 kV)

> PowerFail module IEC/EN 61000-4-8/-11/-29 (DC)

> Built-in single phase coupler 300 V/16 A

> Manual operation from front panel

> USB and GPIB-Bus for remote control

APPLICATION AREAS

INDUSTRY

MEDICAL

RESIDENTIAL

TELECOM

COMPONENTS

BROADCAST

RENEWABLE ENERGY

www.emtest.com © EM TEST > PAGE 1/9

Page 2: UCS 500N5T SERIES - GOmeasuregomeasure.dk/wp-content/uploads/2017/02/UCS500N5T.pdf · range the current transformer MC 2630 is used while high-field strength above 100 A/m requires

DATA SHEET > UCS 500N5T > 20151007

TECHNICAL DETAILS

BENEFITS

ALL IN ONE - ALL WHAT YOU NEED FOR YOUR TESTS

The UCS 500N5T Series includes everything necessary toconduct fully compliant tests. The power mains supply forthe controls and for the DUT is separate to render it moreflexible to use with different DUT supply voltages.The UCS 500N5T Series can be operated manually fromthe front panel or by remote via the built-in USB or GPIBinterface. Fail inputs allow to control an ongoing testsequence based on the status of the DUT. Monitoringoutputs (BNC) are offered for easy signal measurementand verification. Safety features such as interlock andwarning lamp control are available.Pre-programmed Standard Test routines allow highestuser convenience. Still the UCS 500N5T Series offers theQuick Start test routine where parameters can be changedon-line during the test to evaluate the susceptibility levelof an individual DUT.

OPERATION

EASY TO OPERATE

Front panel menu and function keys enable the user toprogram his test routines quickly and accurately. Thecursor allows fast control of all test parameters of theprogrammed routine, thus test procedures are simplifiedand confidence is generated that every step is carried outcorrectly.

SOFTWARE

IEC.CONTROL SOFTWARE FOR CONTROL ANDDOCUMENTATION

User convenience, clearly structured windows andoperation features and the unique EM TEST standardslibrary along with the flexibility to generate user specifictest sequences very easily are the main features ofiec.control software. The software is automaticallyconfigured according to the connected EM TESTgenerators. Extensive reporting capabilities help the userto create test reports that meet internationalrequirements.iec.control is supported by Windows XP, Windows Vista,Windows 7 and Windows 8. Remote control is achievedeither via USB or GPIB. iec.control supports a wide rangeof GPIB cards of National Instruments.

OTHER MODELS

UCS 500N SERIES - COMPACT TESTERS UP TO 7KV

The ultra-compact testers UCS 500NT for EFT/Burst, Surgeand Power Fail are available in different models; withvoltage capability up to 5.5 kV or up to 7 kV.

www.emtest.com © EM TEST > PAGE 2/9

Page 3: UCS 500N5T SERIES - GOmeasuregomeasure.dk/wp-content/uploads/2017/02/UCS500N5T.pdf · range the current transformer MC 2630 is used while high-field strength above 100 A/m requires

DATA SHEET > UCS 500N5T > 20151007

TECHNICAL DETAILS

AUXILIARY DEVICES

CNI 503 - 3PHASE COUPLING/DECOUPLING NETWORKSFOR BURST AND SURGE

EM TEST offers a range of fully automatic 3-phasecoupling/decoupling networks for burst and surge toextend the test capability for three-phase DUTs. Thenetworks have a rated current of up to 200 A.

MV 2616 / MV 2632 - MOTORISED VARIAC FOR VOLTAGEVARIATION

A motorised variac is offered as an alternative to thetapped autotransformers for voltage dips/interruptionsand voltage variation tests as per IEC/EN 61000-4-11. Themotorised variac can also be used for automatedmagnetic field tests.

V 4780 - TAPPED VOLTAGE TRANSFORMER FOR VOLTAGEDIPS

The V 4780 tapped autotransformer is designed to supplythe required voltages as per IEC 61000-4-11 Ed.2:2004 toperform voltage dips.

V 4780S2 - TAPPED VOLTAGE TRANSFORMER FORVOLTAGE DIPS

The V 4780S2 tapped autotransformer is designed tosupply the required voltages as per IEC 61000-4-11Ed.2:2004 to perform voltage dips. Compared to themanually operated V 4780 the V 4780S2 model offersautomatic change of taps according to the selectedvoltage level.

CNV 504/508 N- AND T SERIES - SURGECOUPLING/DECOUPLING NETWORKS FOR SIGNAL/DATALINES

CNV 504/508N- and T-series coupling/decouplingnetworks are available to perform surge tests on I/O lines,signal/data lines and telecom lines as per IEC/EN61000-4-5 Ed 3.0.

ACCESSORIES

MS 100N - MAGNETIC FIELD COIL FOR POWER-FREQUENCYAND PULSED MAGNETIC FIELDS

The MS 100N is a 1sqm magnetic field coil as specified inIEC/EN 61000-4-8 and IEC/EN 61000-4-9. Its designallows easy moving of the coil. The field coil is adjustablein height and allows for 360degr rotation.To generate power-frequency magnetic fields in the lowerrange the current transformer MC 2630 is used whilehigh-field strength above 100 A/m requires the MC 26100current transformer.

HFK - CAPACITIVE COUPLING CLAMP

Capacitive coupling clamp as per specification IEC/EN61000-4-4.

ITP - IMMUNITY TEST PROBES

ITP is a tool being used for development test. It consistsof a variety of electrical field probes. The probes allow tolocate weak points within a system or on a PCB. The burstpulse is used to generate the disturbance signal.

CA EFT KIT - VERIFICATION KIT FOR EFT/BURST PULSES

The pulse shape of EFT/burst generators designed as perIEC/EN 61000-4-4 have to be verified both into a 50ohmand a1,000ohm load at the 50ohm coaxial HV output as wellinto 50ohm load at the output of the coupling networkwhere the DUT is connected when testing mains supplylines.The CA EFT kit includes the load resistors and a set ofadapter to connect the coaxial matching resistorsappropriately to theDUT output port.

CA HFK KIT - VERIFICATION FOR CAPACITIVE COUPLINGCLAMP

The IEC/EN 61000-4-4 Ed 3.0 published 2012 recomendsthe calibration of the capacitive coupling clamp into a50ohm coaxial load.The capacitive coupling clamp (HFK) is connected to the50 ohm output of the EFT generator. A flexible insulatedplate inside the HFK is connected to a coaxial 50 ohmload resistor for verificate the EFT / Burst wave of thecapacitive coupling clamp.

www.emtest.com © EM TEST > PAGE 3/9

Page 4: UCS 500N5T SERIES - GOmeasuregomeasure.dk/wp-content/uploads/2017/02/UCS500N5T.pdf · range the current transformer MC 2630 is used while high-field strength above 100 A/m requires

DATA SHEET > UCS 500N5T > 20151007

TECHNICAL DETAILS

MODEL OVERVIEW

UCS 500N5T SERIES

UCS 500N5T AC: 300 V / 16 A; 50/60 HzDC: 300 V / 16 A

UCS 500N5.1T AC: 300 V / 32 A; 50/60 HzDC: 300 V / 32 A

ELECTRICAL FAST TRANSIENTS

BURST MODULE, EFT/N5

As per IEC/EN 61000-4-4 and EN 61000-6-1, -6-2

Test voltage 200 V - 5,500 V ± 10%;100 V - 2,750 V ± 10% into 50 ohm

Pulse shape 5/50 ns into 50ohm and 1,000 ohm

Rise time tr 5 ns ± 30% into 50 ohm;5 ns ± 30% into 1,000 ohm

Pulse width td 50 ns ± 30% into 50 ohm;50 ns -15/+100 ns into 1,000 ohm

Source impedance 50 ohm

Polarity Positive/negative

TRIGGER CIRCUIT

Trigger of bursts Automatic, manual, external

Synchronization 0° - 360°, resolution 1° (16 - 500 Hz)

Burst duration td = 0.10 ms - 999 ms

Repetition rate tr = 10 ms - 9,999 ms

Spike frequency f = 0.1 kHz - 1,000 kHz

Test duration T = 0:01 min - 99:59 minT > 99:59 min --> endless

OUTPUTS

Direct Via 50 ohm coaxial connector

Coupling mode L, N, PE; all combinations

CRO trigger 5 V trigger signal for oscilloscope

ELECTRICAL FAST TRANSIENTS

TEST ROUTINES

Quick Start On-line adjustable parameters,easy-to-use

Standard Testroutines

As per IEC/EN 61000-4-4, Levels 1 -4As per IEC/EN 61000-6-1, -6-2Manual Standard Test routine

User Test routines Synchronous burst releaseRandom burst releaseChange voltage after TFrequency sweep within one burstFrequency sweep with constantnumber of pulsesFrequency sweep with constant burst durationChange polarity after T

OPTIONS

HFK Capacitive coupling clamp as per IEC/EN 61000-4-4

KW50 100:1 divider, 50ohm

KW1000 500:1 divider, 1,000 ohm

CA EFT kit Kit for burst pulse verificationconsisting of KW 50, KW 1000 andadapter for DUT port in a plastic casefor storage

CA HFK kit Adapter set for capacitive couplingclamp calibration included:- Transducer plate as per IEC/EN61000-4-4 Ed 3.0- Support for positioning the KW 50adapter on 100mm height as thecapacitive coupling clamp

CA MC F Adapter to match KW 50 loadresistor to the EUT supply of3-phaseN-series coupling network

A6dB 6 dB attenuator, 50 ohm

ITP Immunity test probes (electrical fieldgeneration)

ITP/H Immunity test probe (magnetic fieldgeneration)

www.emtest.com © EM TEST > PAGE 4/9

Page 5: UCS 500N5T SERIES - GOmeasuregomeasure.dk/wp-content/uploads/2017/02/UCS500N5T.pdf · range the current transformer MC 2630 is used while high-field strength above 100 A/m requires

DATA SHEET > UCS 500N5T > 20151007

TECHNICAL DETAILS

COMBINATION WAVE / SURGE

SURGE MODULE, VCS/N5

As per IEC/EN 61000-4-5 and IEC/EN 61000-6-1, -6-2

Voltage (o.c.) 160 V - 5,000 V ± 10%

Pulse front time 1.2 us ± 30%

Pulse time to halfvalue

50 us ± 20%

Current (s.c.) Max. 2,500 A ± 10%

Pulse front time 8 us ± 20%

Pulse time to halfvalue

20 us ± 20%

Polarity Positive/negative/alternating

Event counter 1 - 30,000 or endless, selectable

TRIGGER CIRCUIT

Release of pulses Automatic, manual, external

Synchronization 0° - 360°, resolution 1°

Repetition rate max. 1 Hz (1 s - 999 s)

OUTPUTS

Direct Via HV connectors for externalcoupling networks (Zi = 2 ohm with optional adapterIMN 2)

Coupling mode Line to lineLine(s) to ground

CRO trigger 5 V trigger signal for oscilloscope

MEASUREMENTS

CRO Û-monitor 10 Vp at 5,00 0V

CRO Î-monitor 10 Vp at 2,500 A

Peak voltage 5,000 V in the LCD display

Peak current 2,500 A in the LCD display

COMBINATION WAVE / SURGE

TEST ROUTINES

Quick Start One-line adjustable parameters,easy-to-use

Standard Testroutines

As per IEC/EN 61000-4-5, Levels 1 -4As per IEC/EN 61000-6-1, -6-2Manual Standard Test routine

User Test routines Change polarity after n pulsesChange coupling after n pulsesChange voltage after n pulsesChange phase angle after n pulses

Pulsed MagneticField

as per IEC/EN 61000-4-9Test levels 100, 300 and 1,000A/mTest level steplessly adjustableunder Quick Start

OPTIONS

CNV504Nx Coupling network for 4 signal/datalines as per IEC/EN 61000-4-5 Ed 3.0

CNV508Nx Coupling network for 8 signal/datalines as per IEC/EN 61000-4-5 Ed 3.0

CNI 508N2Assembly

Set of coupling/decoupling andprotection networks for testingunshielded and shielded high-speedcommunication lines (Ethernet lines)

IMN 2 Impedance matching adapter tomatch direct output to 2 ohm sourceimpedance

www.emtest.com © EM TEST > PAGE 5/9

Page 6: UCS 500N5T SERIES - GOmeasuregomeasure.dk/wp-content/uploads/2017/02/UCS500N5T.pdf · range the current transformer MC 2630 is used while high-field strength above 100 A/m requires

DATA SHEET > UCS 500N5T > 20151007

TECHNICAL DETAILS

POWER FAIL, DIPS & INTER-RUPTIONS, VOLTAGE VARIATIONS

POWER FAIL MODULE, PFS/N5

As per EN/IEC 61000-4-11, IEC/EN 61000-4-29 and IEC/EN 61000-6-1, -6-2

UCS 500N5TChannel PF1/PF2

AC voltage: max. 30 0VAC current: max. 16 ADC voltage: max. 30 0VDC current: max. 16 A

UCS 500N5.1TChannel PF1/PF2

AC voltage: max. 300 VAC current: max. 32 ADC voltage: max. 300 VDC current: max. 32 A

Frequency 16 Hz - 500 Hz and DC

Switching time < 5 us into a 100 ohm resistive load

Inrush current > 500 A

Protection Both channels are protected againstshort-circuit conditions.

TRIGGER CIRCUIT

Trigger of events Automatic, manual, external

Synchronization 0° - 360°, resolution 1° (16 - 500 Hz)

Repetition rate 10 ms - 9,999 s

Event duration 20 us - 9,999 s

OUTPUTS

DUT terminals L, N and PE

CRO trigger 5 V trigger signal for oscilloscope

MEASUREMENTS

DUT voltage In the LCD display

DUT current In the LCD display

MON V Measurement of the DUT voltage;built-in 100:1 divider

MON I Measurement of the DUT current; 10mV/A; max. 1,000 A

POWER FAIL, DIPS & INTER-RUPTIONS, VOLTAGE VARIATIONS

TEST ROUTINES

Quick Start On-line adjustable parameters,easy-to-use

Standard Testroutines

As per IEC/EN 61000-4-11 for AC suppliesAs per IEC/EN 61000-4-29 for DCsuppliesAs per EN 61000-6-1, -6-2Manual Standard Test routine

User Test routines Voltage variation, control of anexternal variacChange phase angle after n eventsChange event duration after neventsInverse mode

50/60Hz magneticfield

As per IEC/EN 61000-4-8Test levels 1, 3, 10 and 30A/m withexternal current transformer MC2630Test levels 100, 300 and 1,000 A/mwith external current transformer MC26100

OPTIONS

V 4780 Tapped autotransformer as perIEC/EN 61000-4-11 Ed.2

V 4780 S2 Tapped autotransformer as perIEC/EN 61000-4-11 Ed.2 withautomatic change of tap

MV 2616 Motorised variac (0 - 260 V, 16 A)

MV 2632 Motorised variac (0 - 260 V, 32 A)

MS 100N Magnetic field coil, 1 m x 1 m

MC 2630 Current transformer for magneticfields up to 30 A/m

MC 26100 Current transformer for magneticfields up to 1,000 A/m

CA PFS Calibration box for inrush currentverification as per IEC/EN61000-4-11

www.emtest.com © EM TEST > PAGE 6/9

Page 7: UCS 500N5T SERIES - GOmeasuregomeasure.dk/wp-content/uploads/2017/02/UCS500N5T.pdf · range the current transformer MC 2630 is used while high-field strength above 100 A/m requires

DATA SHEET > UCS 500N5T > 20151007

TECHNICAL DETAILS

TELECOM SURGE

TSURGE MODULE, TSURGE5

Test voltage 160 V - 5,000 V ± 10%

Energy storagecapacitor

20 uF

Polarity Positive, negative, alternating

Counter 1 - 30,000 or endless, selctable

As per ITU and ETSIrecommendations

Front time 10 us ± 30%

Pulse duration 700 us ± 20%

As per FCC part 68, Pulse B

Front time 9 us ± 30%

Pulse duration 720 us ± 20%

Output current@25 ohm output

4 - 125 A (short-circuit)

Rise time 5 us ± 30%

Pulse duration 320 us ± 20%

As per IEC/EN 61000-4-5

Rise time 10 us ± 30%

Pulse duration 700 us ± 20%

Output current@25 ohm output

4 A - 125 A (short-circuit)

Rise time 5 us ± 20%

Pulse duration 320 us ± 20%

TELECOM SURGE

TRIGGER CIRCUIT

Trigger of events Automatic, manual, external

Repetition rate max. 0.5 Hz (2 s - 999 s)

OUTPUTS

As per ITU For 2-wire T1/T2 with 25 ohm each

As per FCC part 68 For 2-wire T1/T2 with 25 ohm each

As per IEC61000-4-5 Ed 3.0

For 4-wire T1,T2,T3,T4 with 25 ohmeach

For other requirements specialoutput configurations are available

OPTIONS

CNV 504T5 Coupling/decoupling network forunshielded symmetrical lines(communication lines) as per IEC/EN61000-4-5 Ed.3 (fig. 10) for 4 lines.

CNV 508T5 Coupling/decoupling network forunshielded symmetrical lines(communication lines) as per IEC/EN61000-4-5 Ed.3 (fig. 10) for 8 lines.

www.emtest.com © EM TEST > PAGE 7/9

Page 8: UCS 500N5T SERIES - GOmeasuregomeasure.dk/wp-content/uploads/2017/02/UCS500N5T.pdf · range the current transformer MC 2630 is used while high-field strength above 100 A/m requires

DATA SHEET > UCS 500N5T > 20151007

TECHNICAL DETAILS

GENERAL DATA

INTERFACES

Serial interface USB

Parallel interface IEEE 488, addresses 1 - 30

Analog output 0 - 10 VDC to control an externaltransformer

CN interface 15pin SubD connector to control anexternal coupling network

Fail inputs DUT monitoring via Fail1 and Fail2input (one each)

DIMENSIONS

Dimensions 19", 6HU, (with TSurge5 module)

Weight approx. 35 kg

MAINS

Supply voltage 115V/230 VAC +10%/-15%

Power approx. 75 W

Frequency 50/60 Hz

Fuses 2 x 2 AT (230 V) or 2 x 4 AT (115 V)

SAFETY

Safety standard IEC/EN 61010

Security circuit Control input (24 VDC)

Warning lamp Floating contact (max. 230 V/6 A)

GENERAL DATA

ACCESSORIES INCLUDED

Mains supply Plug depends on the country of use

DUT supply Plug depends on the country of use

DUT adapter Socket depends on the country ofuse

Operation manual, Calibration certificate, iec.control remote control software

OPTIONS

CNI 503Ax 3-phase coupling/decouplingnetworks as per IEC/EN 61000-4-4and -4-5 up to 200 A per phase

iec.control 1 Remote control and documentationsoftware, including standard testroutines and reporting capabilities.

www.emtest.com © EM TEST > PAGE 8/9

Page 9: UCS 500N5T SERIES - GOmeasuregomeasure.dk/wp-content/uploads/2017/02/UCS500N5T.pdf · range the current transformer MC 2630 is used while high-field strength above 100 A/m requires

DATA SHEET > UCS 500N5T > 20151007

COMPETENCE WHEREVERYOU ARE

CONTACT EM TEST DIRECTLY

SwitzerlandEM TEST (Switzerland) GmbH > Sternenhofstraße 15 > 4153 Reinach >SwitzerlandPhone +41 (0)61/7179191 > Fax +41 (0)61/7179199Internet: www.emtest.ch > E-mail: [email protected]

GermanyAMETEK CTS Germany GmbH > Lünener Straße 211 > 59174 Kamen >DeutschlandPhone +49 (0)2307/26070-0 > Fax +49 (0)2307/17050Internet: www.emtest.com > E-mail: [email protected]

FranceEM TEST FRANCE > Le Trident - Parc des Collines > Immeuble B1 - Etage 3 > 36, rue Paul Cézanne > 68200 Mulhouse > FrancePhone +33 (0)389 31 23 50 > Fax +33 (0)389 31 23 55Internet: www.emtest.fr > E-mail: [email protected]

PolandEM TEST Polska > ul. Ogrodowa 31/35, 00-893 Warszawa > Polska Phone +48 (0)518 64 35 12Internet: www.emtest.com/pl > E-mail: [email protected]

USA / CanadaAMETEK Compliance Test Solutions > 52 Mayfield Ave. > Edison > NJ 08837Phone +1 (732) 417-0501Internet: www.emtest.com > E-mail: [email protected]

P.R. ChinaE & S Test Technology Limited > Rm 913, Leftbank > No. 68 Bei Si Huan Xi Lu > Haidian District > Beijing 100080 > P.R. ChinaPhone +86 (0)10 82 67 60 27 > Fax +86 (0)10 82 67 62 38Internet: www.emtest.com > E-mail: [email protected]

Republic of KoreaEM TEST Korea Limited > #405 > WooYeon Plaza > #986-8 > YoungDeok-dong >Giheung-gu > Yongin-si > Gyeonggi-do > KoreaPhone +82 (31) 216 8616 > Fax +82 (31) 216 8616Internet: www.emtest.co.kr > E-mail: [email protected]

Information about scope of delivery, visual design and technical data correspond with the state of development at time of release. Subject tochange without further notice.

www.emtest.com © EM TEST > PAGE 9/9