Typical Characteristics For P8T-100M40G-95-T-512-292FF-IND€¦ · P8T-100M40G-95-T-512-292FF-IND...

12
Typical Characteristics For P8T-100M40G-95-T-512-292FF-IND S# PL16286 PMI MODEL P8T-100M40G-95-T-512-292FF-IND IS A HIGH SPEED, SINGLE POLE, EIGHT THROW, ABSORPTIVE SWITCH THAT OPERATES OVER THE 0.1 TO 40 GHz FREQUENCY RANGE. THIS MODEL IS DESIGNED TO ACHIEVE OVER 80 dB OF ISOLATION AND SWITCHES IN LESS THAN 100ns ALL IN A SLIMLINE PACKAGE MEASURING ONLY 4.0” X 1.5” X 0.4”. November 6, 2015 Report By: Paul Kuhn, Michael Benjamins 7311F Grove Road Frederick, MD 21704 USA Phone: (301)6625019 Fax: (301)6621731 Website: www.pmirf.com Email: sales@pmirf.com 1 of 12 Pages

Transcript of Typical Characteristics For P8T-100M40G-95-T-512-292FF-IND€¦ · P8T-100M40G-95-T-512-292FF-IND...

Page 1: Typical Characteristics For P8T-100M40G-95-T-512-292FF-IND€¦ · P8T-100M40G-95-T-512-292FF-IND S# PL16286 ‐6 ‐5 ‐4 ‐3 ‐2 ‐1 02468 10 12 14 16 18 Insertion Loss (-dB)

Typical CharacteristicsFor

P8T-100M40G-95-T-512-292FF-IND

S# PL16286

PMI MODEL P8T-100M40G-95-T-512-292FF-IND IS A HIGH SPEED, SINGLE POLE, EIGHT THROW, ABSORPTIVE SWITCH THAT OPERATES OVER THE 0.1 TO 40 GHz FREQUENCY

RANGE. THIS MODEL IS DESIGNED TO ACHIEVE OVER 80 dB OF ISOLATION AND SWITCHES IN LESS THAN 100ns ALL IN A SLIMLINE PACKAGE MEASURING ONLY

4.0” X 1.5” X 0.4”.

November 6, 2015Report By: Paul Kuhn, Michael Benjamins

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 1 of 12 Pages

Page 2: Typical Characteristics For P8T-100M40G-95-T-512-292FF-IND€¦ · P8T-100M40G-95-T-512-292FF-IND S# PL16286 ‐6 ‐5 ‐4 ‐3 ‐2 ‐1 02468 10 12 14 16 18 Insertion Loss (-dB)

Typical CharacteristicsFor

P8T-100M40G-95-T-512-292FF-IND

S# PL16286

7. Switching Speed: ········································································································ Page 10

6. Isolation Vs. Frequency: ····························································································· Page 9

4. Input/Output Return Loss Vs. Frequency: ·································································· Page 6

5. Termination Return Loss Vs. Frequency: ··································································· Page 8

2. Summary Data: ··········································································································· Page 4

3. Inserstion Loss Vs. Frequency: ··················································································· Page 5

Table of Contents

1. Product Feature: ·········································································································· Page 3

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 2 of 12 Pages

Page 3: Typical Characteristics For P8T-100M40G-95-T-512-292FF-IND€¦ · P8T-100M40G-95-T-512-292FF-IND S# PL16286 ‐6 ‐5 ‐4 ‐3 ‐2 ‐1 02468 10 12 14 16 18 Insertion Loss (-dB)

Typical CharacteristicsFor

P8T-100M40G-95-T-512-292FF-IND

S# PL16286

Product Feature

PLANAR MONOLITHICS INDUSTRIES, INC.7311-F GROVE ROAD

FREDERICK, MARYLAND 21704 USA

WEBSITE: [email protected]

ISO 9001 CERTIFIED

TEL: 301-662-5019 FAX: 301-662-1731FREDERICK, MARYLAND 21704 USA

E-MAIL: WEBSITE:

” ” ”

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 3 of 12 Pages

Page 4: Typical Characteristics For P8T-100M40G-95-T-512-292FF-IND€¦ · P8T-100M40G-95-T-512-292FF-IND S# PL16286 ‐6 ‐5 ‐4 ‐3 ‐2 ‐1 02468 10 12 14 16 18 Insertion Loss (-dB)

Typical CharacteristicsFor

P8T-100M40G-95-T-512-292FF-IND

S# PL16286

5 Operating Input Power +20 dBm CW +20 dBm CW

6 Switching Speed 100 ns MAX. 60 ns

7 Power Supply+5V @ 500 mA

-12V @ 200 mA+5 @ 202 mA-12 @71 mA

-8.5 dB (J1-J6)

-4.5 dB -5.5 dB -7.8 dB (J1-J7)

4 VSWR 2.5:1 TYP

2.41:1 (J1-J2); 2.40:1 (J1-J3)2.32:1 (J1-J4); 2.45:1 (J1-J5)2.31:1 (J1-J6); 2.24:1 (J1-J7)2.34:1 (J1-J8); 2.44:1 (J1-J9)

3 Insertion Loss

11 dB MAX6 dB TYP (0.1 TO 18 GHz)

7 dB TYP (18 TO 26.5 GHz)10 dB TYP (26.5 TO 40 GHz)

0.1-18 18-26.5 26.5-40

-5.4 dB -8.7 dB

-4.5 dB -5.7 dB

-6.0 dB -8.1 dB

PORTGHz GHz GHz

-4.7 dB -6.1 dB -8.5 dB (J1-J2)

-4.1 dB (J1-J3)

-4.3 dB -5.1 dB -7.9 dB (J1-J4)

-4.3 dB -5.6 dB -7.7 dB (J1-J5)

-4.5 dB -5.0 dB -8.1 dB (J1-J8)

-4.7 dB (J1-J9)

-90.9 dB (J1-J3)

-111.5 dB -91.4 dB (J1-J8)

-111.8 dB -91.4 dB (J1-J9)

-113.3 dB -91.0 dB (J1-J6)

-113.3 dB -91.3 dB (J1-J7)

1 Frequency Range 0.1 GHz to 40.0 GHz 0.1 GHz to 40.0 GHz

2 Isolation90 dB MIN (0.1 TO 18 GHz)80 dB MIN (18 TO 40 GHz)

0.1 to 18 18 to 40

-108.4 dB -91.7 dB (J1-J4)

-111.9 dB -93.3 dB (J1-J5)

PORTGHz GHz

-108.4 dB -94.6 dB (J1-J2)

-110.2 dB

Summary Data

TEST ITEM NO

PARAMETERS SPECIFIED VALUE TEST RESULTS QA QC

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 4 of 12 Pages

Page 5: Typical Characteristics For P8T-100M40G-95-T-512-292FF-IND€¦ · P8T-100M40G-95-T-512-292FF-IND S# PL16286 ‐6 ‐5 ‐4 ‐3 ‐2 ‐1 02468 10 12 14 16 18 Insertion Loss (-dB)

Typical CharacteristicsFor

P8T-100M40G-95-T-512-292FF-IND

S# PL16286

‐6

‐5

‐4

‐3

‐2

‐1

0 2 4 6 8 10 12 14 16 18

Inse

rtio

n Lo

ss (

-dB

)

Frequency (GHz)

Inserstion Loss Vs. Frequency (0.1 to 18 GHz) J2

J3

J4

J5

J6

J7

J8

J9

‐7

‐6

‐5

‐4

‐3

18 20 22 24 26

Inse

rtio

n Lo

ss (

-dB

)

Frequency (GHz)

Inserstion Loss Vs. Frequency (18 to 26.5 GHz) J2

J3

J4

J5

J6

J7

J8

J9

‐11

‐10

‐9

‐8

‐7

‐6

‐5

‐4

26.5 28.5 30.5 32.5 34.5 36.5 38.5

Inse

rtio

n Lo

ss (

-dB

)

Frequency (GHz)

Inserstion Loss Vs. Frequency (26.5 to 40 GHz) J2

J3

J4

J5

J6

J7

J8

J9

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 5 of 12 Pages

Page 6: Typical Characteristics For P8T-100M40G-95-T-512-292FF-IND€¦ · P8T-100M40G-95-T-512-292FF-IND S# PL16286 ‐6 ‐5 ‐4 ‐3 ‐2 ‐1 02468 10 12 14 16 18 Insertion Loss (-dB)

Typical CharacteristicsFor

P8T-100M40G-95-T-512-292FF-IND

S# PL16286

‐40

‐35

‐30

‐25

‐20

‐15

‐10

‐5

0

0 2 4 6 8 10 12 14 16 18

Ret

urn

Loss

(-d

B)

Frequency (GHz)

Input Return Loss Vs. Frequency (0.1 to 18 GHz)

J2

J3

J4

J5

J7

J8

J9

‐40

‐35

‐30

‐25

‐20

‐15

‐10

‐5

0

0 2 4 6 8 10 12 14 16 18

Ret

urn

Loss

(-d

B)

Frequency (GHz)

Output Return Loss Vs. Frequency (0.1 to 18 GHz)

J2

J3

J4

J5

J7

J8

J9

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 6 of 12 Pages

Page 7: Typical Characteristics For P8T-100M40G-95-T-512-292FF-IND€¦ · P8T-100M40G-95-T-512-292FF-IND S# PL16286 ‐6 ‐5 ‐4 ‐3 ‐2 ‐1 02468 10 12 14 16 18 Insertion Loss (-dB)

Typical CharacteristicsFor

P8T-100M40G-95-T-512-292FF-IND

S# PL16286

‐40

‐35

‐30

‐25

‐20

‐15

‐10

‐5

0

18 20 22 24 26 28 30 32 34 36 38 40

Ret

urn

Loss

(-d

B)

Frequency (GHz)

Input Return Loss Vs. Frequency (18 to 40 GHz)

J2

J3

J4

J5

J7

J8

J9

‐40

‐35

‐30

‐25

‐20

‐15

‐10

‐5

0

18 20 22 24 26 28 30 32 34 36 38 40

Ret

urn

Loss

(-d

B)

Frequency (GHz)

Output Return Loss Vs. Frequency (18 to 40 GHz)

J2

J3

J4

J5

J7

J8

J9

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 7 of 12 Pages

Page 8: Typical Characteristics For P8T-100M40G-95-T-512-292FF-IND€¦ · P8T-100M40G-95-T-512-292FF-IND S# PL16286 ‐6 ‐5 ‐4 ‐3 ‐2 ‐1 02468 10 12 14 16 18 Insertion Loss (-dB)

Typical CharacteristicsFor

P8T-100M40G-95-T-512-292FF-IND

S# PL16286

‐40

‐35

‐30

‐25

‐20

‐15

‐10

‐5

0

0 2 4 6 8 10 12 14 16 18

Ret

urn

Loss

(-d

B)

Frequency (GHz)

Termination Return Loss Vs. Frequency (0.1 to 18 GHz)

J2

J3

J4

J5

J6

J7

J8

J9

‐40

‐35

‐30

‐25

‐20

‐15

‐10

‐5

0

18 20 22 24 26 28 30 32 34 36 38 40

Ret

urn

Loss

(-d

B)

Frequency (GHz)

Termination Return Loss Vs. Frequency (18 to 40 GHz)

J2

J3

J4

J5

J6

J7

J8

J9

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 8 of 12 Pages

Page 9: Typical Characteristics For P8T-100M40G-95-T-512-292FF-IND€¦ · P8T-100M40G-95-T-512-292FF-IND S# PL16286 ‐6 ‐5 ‐4 ‐3 ‐2 ‐1 02468 10 12 14 16 18 Insertion Loss (-dB)

Typical CharacteristicsFor

P8T-100M40G-95-T-512-292FF-IND

S# PL16286

‐140

‐130

‐120

‐110

‐100

‐90

0 2 4 6 8 10 12 14 16 18

Isol

atio

n (-

dB)

Frequency (GHz)

Isolation Vs. Frequency (0.1 to 18 GHz)

J2

J3

J4

J5

J6

J7

J8

J9

‐130

‐120

‐110

‐100

‐90

‐80

18 20 22 24 26 28 30 32 34 36 38 40

Isol

atio

n (-

dB)

Frequency (GHz)

Isolation Vs. Frequency (18 to 40 GHz)

J2

J3

J4

J5

J6

J7

J8

J9

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 9 of 12 Pages

Page 10: Typical Characteristics For P8T-100M40G-95-T-512-292FF-IND€¦ · P8T-100M40G-95-T-512-292FF-IND S# PL16286 ‐6 ‐5 ‐4 ‐3 ‐2 ‐1 02468 10 12 14 16 18 Insertion Loss (-dB)

Typical CharacteristicsFor

P8T-100M40G-95-T-512-292FF-IND

S# PL16286

Yellow Trace:  Logic Input Pulse

Green Trace: RF Measured with a Crystal Detector

Switching Speed

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 10 of 12 Pages

Page 11: Typical Characteristics For P8T-100M40G-95-T-512-292FF-IND€¦ · P8T-100M40G-95-T-512-292FF-IND S# PL16286 ‐6 ‐5 ‐4 ‐3 ‐2 ‐1 02468 10 12 14 16 18 Insertion Loss (-dB)

Typical CharacteristicsFor

P8T-100M40G-95-T-512-292FF-IND

S# PL16286

Yellow Trace:  Logic Input Pulse

Green Trace: RF Measured with a Crystal Detector

Switching Speed

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 11 of 12 Pages

Page 12: Typical Characteristics For P8T-100M40G-95-T-512-292FF-IND€¦ · P8T-100M40G-95-T-512-292FF-IND S# PL16286 ‐6 ‐5 ‐4 ‐3 ‐2 ‐1 02468 10 12 14 16 18 Insertion Loss (-dB)

Typical CharacteristicsFor

P8T-100M40G-95-T-512-292FF-IND

S# PL16286

Yellow Trace:  Logic Input Pulse

Green Trace: RF Measured with a Crystal Detector

Switching Speed

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 12 of 12 Pages