Typical Characteristics For P8T-100M40G-95-T-512-292FF-IND€¦ · P8T-100M40G-95-T-512-292FF-IND...
Transcript of Typical Characteristics For P8T-100M40G-95-T-512-292FF-IND€¦ · P8T-100M40G-95-T-512-292FF-IND...
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
S# PL16286
PMI MODEL P8T-100M40G-95-T-512-292FF-IND IS A HIGH SPEED, SINGLE POLE, EIGHT THROW, ABSORPTIVE SWITCH THAT OPERATES OVER THE 0.1 TO 40 GHz FREQUENCY
RANGE. THIS MODEL IS DESIGNED TO ACHIEVE OVER 80 dB OF ISOLATION AND SWITCHES IN LESS THAN 100ns ALL IN A SLIMLINE PACKAGE MEASURING ONLY
4.0” X 1.5” X 0.4”.
November 6, 2015Report By: Paul Kuhn, Michael Benjamins
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 1 of 12 Pages
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
S# PL16286
7. Switching Speed: ········································································································ Page 10
6. Isolation Vs. Frequency: ····························································································· Page 9
4. Input/Output Return Loss Vs. Frequency: ·································································· Page 6
5. Termination Return Loss Vs. Frequency: ··································································· Page 8
2. Summary Data: ··········································································································· Page 4
3. Inserstion Loss Vs. Frequency: ··················································································· Page 5
Table of Contents
1. Product Feature: ·········································································································· Page 3
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 2 of 12 Pages
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
S# PL16286
Product Feature
PLANAR MONOLITHICS INDUSTRIES, INC.7311-F GROVE ROAD
FREDERICK, MARYLAND 21704 USA
WEBSITE: [email protected]
ISO 9001 CERTIFIED
TEL: 301-662-5019 FAX: 301-662-1731FREDERICK, MARYLAND 21704 USA
E-MAIL: WEBSITE:
” ” ”
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 3 of 12 Pages
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
S# PL16286
5 Operating Input Power +20 dBm CW +20 dBm CW
6 Switching Speed 100 ns MAX. 60 ns
7 Power Supply+5V @ 500 mA
-12V @ 200 mA+5 @ 202 mA-12 @71 mA
-8.5 dB (J1-J6)
-4.5 dB -5.5 dB -7.8 dB (J1-J7)
4 VSWR 2.5:1 TYP
2.41:1 (J1-J2); 2.40:1 (J1-J3)2.32:1 (J1-J4); 2.45:1 (J1-J5)2.31:1 (J1-J6); 2.24:1 (J1-J7)2.34:1 (J1-J8); 2.44:1 (J1-J9)
3 Insertion Loss
11 dB MAX6 dB TYP (0.1 TO 18 GHz)
7 dB TYP (18 TO 26.5 GHz)10 dB TYP (26.5 TO 40 GHz)
0.1-18 18-26.5 26.5-40
-5.4 dB -8.7 dB
-4.5 dB -5.7 dB
-6.0 dB -8.1 dB
PORTGHz GHz GHz
-4.7 dB -6.1 dB -8.5 dB (J1-J2)
-4.1 dB (J1-J3)
-4.3 dB -5.1 dB -7.9 dB (J1-J4)
-4.3 dB -5.6 dB -7.7 dB (J1-J5)
-4.5 dB -5.0 dB -8.1 dB (J1-J8)
-4.7 dB (J1-J9)
-90.9 dB (J1-J3)
-111.5 dB -91.4 dB (J1-J8)
-111.8 dB -91.4 dB (J1-J9)
-113.3 dB -91.0 dB (J1-J6)
-113.3 dB -91.3 dB (J1-J7)
1 Frequency Range 0.1 GHz to 40.0 GHz 0.1 GHz to 40.0 GHz
2 Isolation90 dB MIN (0.1 TO 18 GHz)80 dB MIN (18 TO 40 GHz)
0.1 to 18 18 to 40
-108.4 dB -91.7 dB (J1-J4)
-111.9 dB -93.3 dB (J1-J5)
PORTGHz GHz
-108.4 dB -94.6 dB (J1-J2)
-110.2 dB
Summary Data
TEST ITEM NO
PARAMETERS SPECIFIED VALUE TEST RESULTS QA QC
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 4 of 12 Pages
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
S# PL16286
‐6
‐5
‐4
‐3
‐2
‐1
0 2 4 6 8 10 12 14 16 18
Inse
rtio
n Lo
ss (
-dB
)
Frequency (GHz)
Inserstion Loss Vs. Frequency (0.1 to 18 GHz) J2
J3
J4
J5
J6
J7
J8
J9
‐7
‐6
‐5
‐4
‐3
18 20 22 24 26
Inse
rtio
n Lo
ss (
-dB
)
Frequency (GHz)
Inserstion Loss Vs. Frequency (18 to 26.5 GHz) J2
J3
J4
J5
J6
J7
J8
J9
‐11
‐10
‐9
‐8
‐7
‐6
‐5
‐4
26.5 28.5 30.5 32.5 34.5 36.5 38.5
Inse
rtio
n Lo
ss (
-dB
)
Frequency (GHz)
Inserstion Loss Vs. Frequency (26.5 to 40 GHz) J2
J3
J4
J5
J6
J7
J8
J9
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 5 of 12 Pages
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
S# PL16286
‐40
‐35
‐30
‐25
‐20
‐15
‐10
‐5
0
0 2 4 6 8 10 12 14 16 18
Ret
urn
Loss
(-d
B)
Frequency (GHz)
Input Return Loss Vs. Frequency (0.1 to 18 GHz)
J2
J3
J4
J5
J7
J8
J9
‐40
‐35
‐30
‐25
‐20
‐15
‐10
‐5
0
0 2 4 6 8 10 12 14 16 18
Ret
urn
Loss
(-d
B)
Frequency (GHz)
Output Return Loss Vs. Frequency (0.1 to 18 GHz)
J2
J3
J4
J5
J7
J8
J9
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 6 of 12 Pages
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
S# PL16286
‐40
‐35
‐30
‐25
‐20
‐15
‐10
‐5
0
18 20 22 24 26 28 30 32 34 36 38 40
Ret
urn
Loss
(-d
B)
Frequency (GHz)
Input Return Loss Vs. Frequency (18 to 40 GHz)
J2
J3
J4
J5
J7
J8
J9
‐40
‐35
‐30
‐25
‐20
‐15
‐10
‐5
0
18 20 22 24 26 28 30 32 34 36 38 40
Ret
urn
Loss
(-d
B)
Frequency (GHz)
Output Return Loss Vs. Frequency (18 to 40 GHz)
J2
J3
J4
J5
J7
J8
J9
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 7 of 12 Pages
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
S# PL16286
‐40
‐35
‐30
‐25
‐20
‐15
‐10
‐5
0
0 2 4 6 8 10 12 14 16 18
Ret
urn
Loss
(-d
B)
Frequency (GHz)
Termination Return Loss Vs. Frequency (0.1 to 18 GHz)
J2
J3
J4
J5
J6
J7
J8
J9
‐40
‐35
‐30
‐25
‐20
‐15
‐10
‐5
0
18 20 22 24 26 28 30 32 34 36 38 40
Ret
urn
Loss
(-d
B)
Frequency (GHz)
Termination Return Loss Vs. Frequency (18 to 40 GHz)
J2
J3
J4
J5
J6
J7
J8
J9
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 8 of 12 Pages
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
S# PL16286
‐140
‐130
‐120
‐110
‐100
‐90
0 2 4 6 8 10 12 14 16 18
Isol
atio
n (-
dB)
Frequency (GHz)
Isolation Vs. Frequency (0.1 to 18 GHz)
J2
J3
J4
J5
J6
J7
J8
J9
‐130
‐120
‐110
‐100
‐90
‐80
18 20 22 24 26 28 30 32 34 36 38 40
Isol
atio
n (-
dB)
Frequency (GHz)
Isolation Vs. Frequency (18 to 40 GHz)
J2
J3
J4
J5
J6
J7
J8
J9
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 9 of 12 Pages
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
S# PL16286
Yellow Trace: Logic Input Pulse
Green Trace: RF Measured with a Crystal Detector
Switching Speed
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 10 of 12 Pages
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
S# PL16286
Yellow Trace: Logic Input Pulse
Green Trace: RF Measured with a Crystal Detector
Switching Speed
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 11 of 12 Pages
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
S# PL16286
Yellow Trace: Logic Input Pulse
Green Trace: RF Measured with a Crystal Detector
Switching Speed
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com 12 of 12 Pages