4
Type VIY-60 Indoor voltage transformer Instrument transformers Product features 5 kV indoor 60 kV BIL, 60 Hertz Primary volts: 2400 - 4800 UL Recognized Component, File No. E148620 Application The VIY-60 indoor voltage transformer is designed for service in metalclad switchgear and is used for relaying, metering, and control power applications. Construction features The primary and secondary coils are wound using special winding and shielding techniques for improved voltage stress distribution. The coils are designed to withstand continuous operation at 1.1 times the line-to-line voltage level and the line-to-ground voltage level for Y burden units. For some line-to-ground voltage units, a short-time withstand voltage of 1.9 is available upon request. Each coil is insulated with mylar film to provide a high dielectric strength between layers. The coils and core are combined to create a complete winding structure that is assembled to a support frame. The entire assembly is vacuum cast in polyurethane for added insulation and protection. Fuse classifications This unit is provided with three fuse classifications: mounted fuse with hardware, unfused with hardware, or unfused without hardware. Optional fuse kits are offered to convert some unfused styles to fused styles. Consult your ABB sales representative concerning overvoltage conditions for designs above the standard rated voltage factor of 1.1. Terminals Compression-type primary terminals accommodate #8 through #2 wire. Secondary brass terminal inserts are 3/8" deep with a .190-32 tapped hole. Secondary terminals are .190-32 compression screws. A compression type terminal that accommodates #14 through #4 wire is provided on fused units on the line end of each fuse. Baseplate The baseplate is constructed of corrosion-resistant aluminum and is secured to the encapsulated base support. Mounting The VIY-60 can be mounted in upright, cantilever, or upside-down positions. Curves Type curves are available upon request. Test reports IEEE test reports are stored electronically and can be e-mailed in various formats at the time of shipment. Standards This unit meets all applicable IEEE and NEMA standards and is a UL Recognized Component. Provided by Northeast Power Systems, Inc. www.nepsi.com

Transcript of Type VIY-60 indoor voltage transformer - Northeast … · 2014-04-16 · ABB product bulletin |...

Page 1: Type VIY-60 indoor voltage transformer - Northeast … · 2014-04-16 · ABB product bulletin | Type VIY-60 indoor voltage transformer 3. Additional styles available upon request.

Type VIY-60Indoor voltage transformer

Instrument transformers

Product features − 5 kV indoor − 60 kV BIL, 60 Hertz − Primary volts: 2400 - 4800 − UL Recognized Component, File No. E148620

ApplicationThe VIY-60 indoor voltage transformer is designed for service in metalclad switchgear and is used for relaying, metering, and control power applications.

Construction featuresThe primary and secondary coils are wound using special winding and shielding techniques for improved voltage stress distribution. The coils are designed to withstand continuous operation at 1.1 times the line-to-line voltage level and the line-to-ground voltage level for Y burden units. For some line-to-ground voltage units, a short-time withstand voltage of 1.9 is available upon request.

Each coil is insulated with mylar film to provide a high dielectric strength between layers. The coils and core are combined to create a complete winding structure that is assembled to a support frame. The entire assembly is vacuum cast in polyurethane for added insulation and protection.

Fuse classificationsThis unit is provided with three fuse classifications: mounted fuse with hardware, unfused with hardware, or unfused without hardware. Optional fuse kits are offered to convert some unfused styles to fused styles. Consult your ABB sales representative concerning overvoltage conditions for designs above the standard rated voltage factor of 1.1.

TerminalsCompression-type primary terminals accommodate #8 through #2 wire. Secondary brass terminal inserts are 3/8" deep with a .190-32 tapped hole. Secondary terminals are .190-32 compression screws. A compression type terminal that accommodates #14 through #4 wire is provided on fused units on the line end of each fuse.

BaseplateThe baseplate is constructed of corrosion-resistant aluminum and is secured to the encapsulated base support.

MountingThe VIY-60 can be mounted in upright, cantilever, or upside-down positions.

CurvesType curves are available upon request.

Test reportsIEEE test reports are stored electronically and can be e-mailed in various formats at the time of shipment.

StandardsThis unit meets all applicable IEEE and NEMA standards and is a UL Recognized Component.

Provided by N

ortheast Pow

er System

s, Inc. w

ww

.nepsi.com

Page 2: Type VIY-60 indoor voltage transformer - Northeast … · 2014-04-16 · ABB product bulletin | Type VIY-60 indoor voltage transformer 3. Additional styles available upon request.

2 Type VIY-60 indoor voltage transformer | ABB product bulletin

Unit dimensions

VIY-60, fused, indicating, one fuse (36 lbs) VIY-60, fused, indicating, two fuses (36 lbs)

1.13[29]

H1

X1

1.06[27]

5.50[140]

8.44[214]

9.32[237]

1.69 [43]

6.94[176]

8.51[216]

9.63[245]

1.31[33]

.44 X 1.50 [11 X 38] SLOT 2-TOTAL

.25-20 TERMSCREW (H2)

Ø.44 [11]2-TOTAL

RATING DECAL2-TOTAL

COMPRESSION TYPE TERMFOR #2 TO #8 WIRE

6.38[162]

.19 SECONDARYTERM SCREWS2-TOTAL

NAMEPLATE

VIY-60, fused, non-indicating, one fuse (39 lbs)

6.95[176]1.13

[29]

8.45[215]

9.32[237]

5.51[140]

8.20[208]

X1

H1

1.06[27]

9.62[244]

.44 X 1.50[11 X 38]SLOT2-TOTAL

Ø.44 [11]2-TOTAL

.19 SECONDARYTERM SCREWS2-TOTAL

RATING DECAL2-TOTALCOMPRESSION TYPE TERM

FOR #2 TO #8 WIRE2-TOTAL

6.38[162]

NAMEPLATE

VIY-60, fused, non-indicating, two fuses (39 lbs)

X1

H1

4.56 [116]9.32 [237]

1.13 [29]

8.68 [221]

4.88 [124]5.13 [130]

1.31 [33]

6.32 [161]

6.94 [176]

4.63 [118] 3.81 [97]5.07 [129] 4.25 [108]

2.75 [70]

2.75 [70]

3.19 [81]

3.19 [81]

1.06 [27]

1.69[43]

1.5 x .44[38 x 11]

SLOT2-TOTAL

Ø .44 [11] HOLE2-TOTAL

.25-20TERM SCREW

COMPRESSION TYPE TERMINAL

FOR #14 TO #4 WIRE

DECAL2-TOTAL

NAMEPLATE

.19 SECONDARYTERMINAL SCREWS2-TOTAL

X1

H1

4.25 [108]

1.13 [29]

8.68[221]

4.88 [124]5.13 [130]

.13 [3]

6.32[161]

6.94[176]

3.81 [97]4.25 [108]

4.63 [118]5.07 [129]

9.32 [237]

2.75[70] 3.19

[81]

2.75[70]

3.19[81]

.19 SECONDARYTERMINAL SCREWS2-TOTAL

NAMEPLATEDECAL

2-TOTAL

COMPRESSION TYPE TERMINAL

FOR #14 TO #4 WIRE2-TOTAL

Ø.44 [11] HOLE2-TOTAL

1.5 x .44[38 x 11] SLOT2-TOTAL

Provided by N

ortheast Pow

er System

s, Inc. w

ww

.nepsi.com

Page 3: Type VIY-60 indoor voltage transformer - Northeast … · 2014-04-16 · ABB product bulletin | Type VIY-60 indoor voltage transformer 3. Additional styles available upon request.

ABB product bulletin | Type VIY-60 indoor voltage transformer 3

Additional styles available upon request. Contact your ABB sales representative or call +1-252-827-3212 for more information.

Baseplate dimensions

Note: 50 Hz styles available

Selection guide

Primary voltageSecondary

voltageWinding

ratioRated voltage

factorNumber of bushings

Number of fuses Style number

Unfused (with no provision for fuse mounting)

2400/4160Y 120 20:1 1.1 2 - 7525A50G01

4200/4200Y 120 35:1 1.1 2 - 7525A50G02

4800/4800Y 120 40:1 1.1 2 - 7525A50G03

Unfused (with provision for fuse mounting)

2400/4160Y 120 20:1 1.1 4 - 7525A54G01

4200/4200Y 120 35:1 1.1 4 - 7525A54G02

4800/4800Y 120 40:1 1.1 4 - 7525A54G03

2400/4160GY 120 20:1 1.1 2 - 7525A55G01

4200/4200GY 120 35:1 1.1 2 - 7525A55G02

4800/4800GY 120 40:1 1.1 2 - 7525A55G03

Fused (indicating)

2400/4160Y 120 20:1 1.1 4 2 7525A51G01

4200/4200Y 120 35:1 1.1 4 2 7525A51G02

4800/4800Y 120 40:1 1.1 4 2 7525A51G03

3300/3300Y 120 27.5:1 1.1 4 2 7525A51G12

3600/3600Y 120 30:1 1.1 4 2 7525A51G08

4160/4160Y 120 34.67:1 1.1 4 2 7525A51G32

2400/4160GY 120 20:1 1.1 2 1 7525A52G01

3300/3300GY 120 27.5:1 1.1 2 1 7525A52G15

4200/4200GY 120 35:1 1.1 2 1 7525A52G02

4800/4800GY 120 40:1 1.1 2 1 7525A52G03

Fused (non-indicating)

2400/4160Y 120 20:1 1.1 4 2 9628A12G01

4200/4200Y 120 35:1 1.1 4 2 9628A12G02

4800/4800Y 120 40:1 1.1 4 2 9628A12G03

2400/4160GY 120 20:1 1.1 2 1 9628A11G01

4200/4200GY 120 35:1 1.1 2 1 9628A11G02

4800/4800GY 120 40:1 1.1 2 1 9628A11G03

Unit dimensions (cont‘d)

X1

H1

3.75 [95]

9.32 [237]

1.13[29]

6.94[176]5.72

[145]

3.00 [76]4.63 [118]

5.07 [129]

3.81 [97]

1.06 [27]

4.25 [108]

2.75[70]

2.75[70]

3.19[81]

3.19[81]

2.10[53]

2.10[53]

DECAL2-TOTAL

1.5 X .44[38 X 11]

SLOT2-TOTAL

Ø.44 HOLE2-TOTAL

.25-20 x .50 DP.TAPPED HOLE

4-TOTAL.25-20 TERM

SCREWSWHEN SUPPLIED

NAMEPLATE

9.31[237]

5.50[140]

7.38[187]

8.44[214]

6.38[162]

Optional accessoriesFuse kits to convert unfused VIY-60 to fused style:

− Two fuses and hardware 7527A97G01 − One fuse and hardware 7527A97G02

Replacement fuses: − Type CLE-PT, 1.0, 5.5 kV (indicating) 50C5225G06 − Type CLE-PT, 1.0, 5.5 kV (non-indicating) 626A33H03

VIY-60, unfused (32 lbs)

Provided by N

ortheast Pow

er System

s, Inc. w

ww

.nepsi.com

Page 4: Type VIY-60 indoor voltage transformer - Northeast … · 2014-04-16 · ABB product bulletin | Type VIY-60 indoor voltage transformer 3. Additional styles available upon request.

1VA

P42

9511

-DB

Feb

ruar

y 20

12 R

ev.

C

For more information please contact: ABB Inc.Medium Voltage Distribution Components3022 NC 43 NorthPinetops, NC 27864 USA Phone: +1 252 827 3212Fax: +1 252 827 4286

www.abb.com/mediumvoltage

Note:

We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction–in whole or in parts– is forbidden without ABB’s prior written consent.

Copyright 2005 ABB. All rights reserved.

UL Recognized Component, File No. E148620

Provided by N

ortheast Pow

er System

s, Inc. w

ww

.nepsi.com