Visit product website DATA SHEET Type 8619 multiCELL - Multi-chan- nel and multi-function transmitter/controller Type 8611 eCONTROL - Universal controller Type 8692 Digital electropneu- matic Positioner for the integrated mounting on process control valves Type 8644 Remote Process Actu- ation Control System AirLINE 1000385105 | Standard | EU | en | 201904 | 00 Radar level meter for liquids suitable for use in applications with aggressive fluids as well as with hygienic requirements • Continuous level measurement up to 30 m, 4…20 mA, 2-wire • Available process connections: Plastic horn antenna, thread (G, NPT ¾ and 1 ½ ), flange (DN50, DN100), clamp (2") Excellent radar signal focusing and high measurement dynamics • Adjustable using the display/configuration module and keys, alter- natively via PC-Tool with DTM The Type 8139 is a non-contact radar level measuring device for continuous level measurement. It is available with: - integrated antenna (G- or NPT connection), especially suitable for level measurement of aggressive liquids, with special advantages for small ves- sels. - plastic horn antenna (with mounting bracket), especially suitable for meas- urements in open flumes or gauge measurement in water. - flange connection (DIN 2501) with encapsulated antenna system, - clamp connection (DIN 32676, ISO 2852) with encapsulated antenna system for hygienic requirements. The high focus of the radar signal and the high measurement dynamics allow excellent measurement results even in small, narrow and high containers, as the risk of signal interference by installations, constructions and vessel walls is much lowered. Signal damping, e.g. due to signal running length, foam build-up, low DK values of the liquids, has a much smaller effect. Product variants described in the data sheet may differ from the product presentation and description. Type description Can be combined with Type 8139 © Christian Bürkert GmbH & Co. KG, Subject to alteration

Transcript of Type 8139 data sheet | Radar level meter for liquids ... · The Type 8139 is a non-contact radar...

Page 1: Type 8139 data sheet | Radar level meter for liquids ... · The Type 8139 is a non-contact radar level measuring device for continuous level measurement. It is available with: - integrated

Visit product website

DATA SHEET

Type 8619

multiCELL - Multi-chan-nel and multi-function transmitter/controller

Type 8611

eCONTROL - Universal controller

Type 8692

Digital electropneu-matic Positioner for the integrated mounting on process control valvesType 8644

Remote Process Actu-ation Control System AirLINE

1000385105 | Standard | EU | en | 201904 | 00

Radar level meter for liquids suitable for use in applications with aggressive fluids as well as with hygienic requirements

• Continuouslevelmeasurementupto30 m,4…20 mA,2-wire

• Availableprocessconnections:Plastichornantenna,thread(G,NPT¾and1½),flange(DN50,DN100),clamp(2")

• Excellent radar signal focusing and high measurement dynamics

• Adjustableusingthedisplay/configurationmoduleandkeys,alter-nativelyviaPC-ToolwithDTM

The Type 8139 is a non-contact radar level measuring device for continuous level measurement.

Itisavailablewith:-integratedantenna(G-orNPTconnection),especiallysuitableforlevelmeasurementofaggressiveliquids,withspecialadvantagesforsmallves-sels.

-plastichornantenna(withmountingbracket),especiallysuitableformeas-urementsinopenflumesorgaugemeasurementinwater.

-flangeconnection(DIN 2501)withencapsulatedantennasystem,-clampconnection(DIN 32676,ISO 2852)withencapsulatedantennasystem

for hygienic requirements.

Thehighfocusoftheradarsignalandthehighmeasurementdynamicsallowexcellentmeasurementresultseveninsmall,narrowandhighcontainers,astheriskofsignalinterferencebyinstallations,constructionsandvesselwallsismuchlowered.Signaldamping,e.g.duetosignalrunninglength,foambuild-up,lowDKvaluesoftheliquids,hasamuchsmallereffect.

Productvariantsdescribedinthedatasheetmaydifferfromtheproductpresentationanddescription.

Type descriptionCan be combined with

Type 8139

©ChristianBürkertGmbH&Co.KG,Subjecttoalteration

Page 2: Type 8139 data sheet | Radar level meter for liquids ... · The Type 8139 is a non-contact radar level measuring device for continuous level measurement. It is available with: - integrated

Type 8139

2 | 18Visit product website

Table of contents

1. General technical data 3

2. Product versions 5

2.1. Plastichornantenna80 mm ..................................................................................................................................................52.2. Threadwithintegratedantenna40 mm .................................................................................................................................52.3. Flangewithencapsulatedantennasystem............................................................................................................................62.4. Hygieneconnectionwithencapsulatedantennasystem ......................................................................................................6

3. Materials 6

3.1. ChemicalResistanceChart–BürkertresistApp....................................................................................................................6

4. Dimensions 7

4.1. Plastichornantenna80 mm ..................................................................................................................................................74.2. Threadwithintegratedantenna40 mm .................................................................................................................................84.3. Flangewithencapsulatedantennasystem............................................................................................................................94.4. Hygieneconnectionwithencapsulatedantennasystem ....................................................................................................10

5. Performancespecifications 10

5.1. Measurement deviation diagram .........................................................................................................................................105.2. Temperature derating diagram .............................................................................................................................................11

Plastichornantenna80 mm ................................................................................................................................................11Threadwithintegratedantenna40 mm ...............................................................................................................................11Flangewithencapsulatedantennasystem..........................................................................................................................11

6. Product installation 12

6.1. Mountingoptions .................................................................................................................................................................12Plastichornantenna80 mmwithmountingbracket ...........................................................................................................12Plastichornantenna80 mmwithflange..............................................................................................................................12

7. Product operation 13

7.1. Measuringprinciple .............................................................................................................................................................137.2. Productoperationnotes ......................................................................................................................................................14

Setupwithdisplay/configurationmodule ...........................................................................................................................14SetupwithPACTware™/DTMandHARTcommunication ..................................................................................................14

8. Product accessories 15

9. Ordering information 16

9.1. BürkerteShop–Easyorderingandquickdelivery ..............................................................................................................169.2. Bürkertproductfilter ............................................................................................................................................................169.3. Ordering chart ......................................................................................................................................................................169.4. Ordering chart accessories ..................................................................................................................................................17

Page 3: Type 8139 data sheet | Radar level meter for liquids ... · The Type 8139 is a non-contact radar level measuring device for continuous level measurement. It is available with: - integrated

Type 8139

3 | 18Visit product website

1. General technical data

Product propertiesMaterialsPleasemakesurethedevicematerialsarecompatiblewiththefluidyouareusing.Detailedinformationcanbefoundinchapter „3.1. Chemical Resistance Chart – Bürkert resistApp“ on page 6.

Non wetted partsDepending on antenna system. Detailed information can be found in chapter „2. Product versions“ on page 5.Housing PlasticPBT(Polyester),PPSandstainlesssteel316L(1.4404)Cover PC transparentSealbetweenhousingandhousingcover EPDMCable gland PABlind plug PAGroundterminal Stainlesssteel316L

Wetted partsDepending on antenna system. Detailed information can be found in chapter „2. Product versions“ on page 5.Powersupplycable • Cablediameter:5…9 mm

• Wirecross-section(spring-loadedterminals):

– Massivewire,strandedwire:0.2…2.5 mm2(AWG24…14)

– Strandedwirewithendsleeve:0.2…1.5 mm2(AWG24…16)Weights Approx.2…17.2 kg(dependingonprocessconnectionandantenna)Beam angle1.) Depending on antenna system. Detailed information can be found in chapter „2. Prod-

uct versions“ on page 5.Blockingdistance NullTemperature drift <0.03%/10Krelatingtothe16 mAspanormax.0.3%Damping(63%oftheinputvariable) 0…999 s,adjustableElectrical dataOperatingvoltage(Un) 12…35 V DCStarting current ≤3.6 mA;≤10 mAfor5 msafterswitchingonOutput signal 4…20 mA/HARTSignal resolution 0.3 µARange of the output signal 3.8…20.5 mA/HART(defaultsetting)Load resistor (Un - Umin)/0.022 AFault signal Currentoutput:mAvalueunchanged,20.5 mA,22 mAor<3.6 mA(adjustable)Outputcurrent(max.) 22 mAResidualripple(permissibleforDC) For12 V<Un<18 V:≤0.7Veff(16…400 Hz)

For18 V<Un<35 V:≤1.0Veff(16…400 Hz)Performance dataMeasuring range Distancebetweentheendofthesensorantennaandtheproductsurface.

Max.30 m(dependingonantennasystem).Detailedinformationcanbefoundinchap-ter „2. Product versions“ on page 5.

Measurement deviation AccordingtoEN 60770-1:≤1 mmforliquids(measuringdistance>0.25 m).Detailedinformation can be found in chapter „5.1. Measurement deviation diagram“ on page 10.

Measuring range resolution 1 mmMeasuring frequency W-Band(80GHztechnology)Measuring cycle time2.) Approx.700 msStep response time2.)3.) ≤3 sVibrationresistance Depending on antenna system. Detailed information can be found in chapter „2. Prod-

uct versions“ on page 5.Shockresistance 100 g,6 msaccordingtoEN60068-2-27(mechanicalshock)Repeatability4.) ≤1 mmMedium dataProcess temperature Depending on antenna system. Detailed information can be found in chapter „2. Prod-

uct versions“ on page 5.Process pressure Depending on antenna system. Detailed information can be found in chapter „2. Prod-

uct versions“ on page 5.

Page 4: Type 8139 data sheet | Radar level meter for liquids ... · The Type 8139 is a non-contact radar level measuring device for continuous level measurement. It is available with: - integrated

Type 8139

4 | 18Visit product website

ApprovalsandCertificates

StandardsProtection class according to IEC/EN 60529

IP66/IP67withcableplugmountedandtightenedM20x1.5

Overvoltage category according to IEC 61010-1

Category III

ProtectionratingaccordingtoIEC 61010-1 Class III

DirectivesCE directives Theappliedstandards,whichverifyconformitywiththeEUDirectives,canbefound

ontheEUTypeExaminationCertificateand/ortheEUDeclarationofconformity(ifapplicable)

NAMUR recommendations NE21- Electromagnetic compatibility of equipmentNE43 - Signal level for fault information from measuring transducersNE53-Compatibilityoffielddevicesanddisplay/adjustmentcomponentsNE107-Self-monitoringanddiagnosisoffielddevices

Product connectionsProcess connection • Mountingbracket170 mm(suppliedasstandard)or300 mm(accessory)(version

withplastichornantenna)

• ThreadGorNPT-¾"or1½"(versionwithintegratedhornantenna)

• FlangeDN50,DN100DIN 2501(versionwithencapsulatedantennasystem)

• Clamp2"DIN 32676,ISO 2852(hygieneconnectionversionwithencapsulatedantenna system)

Electrical connections Cable gland M20 x 1.5Environment and installationAmbient temperature Operationandstorage:-40…+80°C(-40…+176°F)Temperature derating Depending on antenna system. Detailed information can be found in chapter „5.2.

Temperature derating diagram“ on page 11.Relative air humidity 20…85%,withoutcondensationHeightabovesealevel Bydefault:max.2000 m

Withconnectedovervoltageprotection:max.5000 mDegree of pollution Grade4(whenusedwithfulfilledhousingprotection)AccessoriesDisplay LCDinfulldotmatrix(optional,mustbeorderedseparately)

1.)Outsidethespecifiedbeamangle,theenergyleveloftheradarsignalis50%(-3 dB)less

2.) With operating voltage Un≥24 V DC

3.)Timespanafterasuddendistancechangefrom1…5 muntiltheoutputsignalreaches90%ofthefinalvalueforthefirsttime(IEC61298-2).

4.) Already included in the measurement deviation

Page 5: Type 8139 data sheet | Radar level meter for liquids ... · The Type 8139 is a non-contact radar level measuring device for continuous level measurement. It is available with: - integrated

Type 8139

5 | 18Visit product website

2. Product versions2.1. Plastichornantenna80 mm

Product detailsMaterials Nonwettedparts:

• AntennaconeinPBT-GF30

• Mountingbracketandfixingscrews,instainlesssteel316L Wetted parts:• Focus lens in PP

Beam angle 3°Measuring range 0…30 mVibrationresistance • Withmountingbracket:1 gwith5…200 HzaccordingtoEN60068-2-6

(vibrationatresonance)

• Withadapterflange(asanoption):2 gwith5…200 HzaccordingtoEN60068-2-6(vibrationatresonance)

Process temperature -40…+80°C(-40…+176°F)Process pressure Withadapterflange:-1…1 bar(-100…100kPa/-14.5…14.5psig)AccessoriesMaterials Nonwettedparts:

• Fixingscrewsforadapterflangeinstainlesssteel304 Wetted parts:• AdapterflangeforPP-GF30black

• SealforadapterflangeinFKM(COGVI500)

2.2. Threadwithintegratedantenna40 mm

Product detailsMaterials Wetted parts:

• Processconnectioninstainlesssteel316L

• AntennainPEEK

• SealAntennasysteminFKM

• ProcesssealinKlingersilC-4400Beam angle • 14°forversionG¾orNPT¾

• 7°forversionG 1½orNPT 1½Measuring range • 0…10 mforversionG¾orNPT¾

• 0…20 mforversionG 1½orNPT 1½Vibrationresistance 4 gwith5…200 HzaccordingtoEN60068-2-6(vibrationatresonance)Process temperature1.) -40…+130°C(-40…+266°F)Process pressure -1…20 bar(-100…2000kPa/-14.5…290.1psig)

1.)Takeintoaccountreducedambienttemperature.Detailedinformationcanbefoundinchapter„5.2. Temperature derating diagram“ on

page 11

Page 6: Type 8139 data sheet | Radar level meter for liquids ... · The Type 8139 is a non-contact radar level measuring device for continuous level measurement. It is available with: - integrated

Type 8139

6|18Visit product website

2.3. Flange with encapsulated antenna system

Product detailsMaterials Wetted parts:

• Flangeplating,antennaencapsulationinPTFE

• Seal in PTFEBeam angle • 6°forversionDN50

• 3°forversionDN100Measuring range • 0…25 mforversionDN50

• 0…30 mforversionDN100Vibrationresistance 4 gwith5…200 HzaccordingtoEN60068-2-6(vibrationatresonance)Process temperature1.) -40…+130°C(-40…+266°F)SIP process temperature +150°C(+302°F),vapourstratificationupto2 hProcess pressure -1…16 bar(-100…1600kPa/-14.5…232psig)

1.)Takeintoaccountreducedambienttemperature.Detailedinformationcanbefoundinchapter„5.2. Temperature derating diagram“ on

page 11

2.4. Hygiene connection with encapsulated antenna system

Product detailsMaterials Wetted parts:

• HygienicantennaencapsulationinPTFE

• Seal in PTFESurface roughness of the antenna encapsulation

Ra<0.8 µm

Beam angle 6°Measuring range 0…25 mProcess temperature -40…+130°C(-40…+266°F)SIP Process temperature +150°C(+302°F),vapourstratificationupto2 hProcess pressure -1…16 bar(-100…1600kPa/-14.5…232psig)

3. Materials3.1. Chemical Resistance Chart – Bürkert resistApp

Bürkert resistApp – Chemical Resistance Chart

Youwanttoensurethereliabilityanddurabilityofthematerialsinyourindividualapplicationcase?Verifyyourcombinationofmediaandmaterialsonourwebsiteorinour resistApp.

Start Chemical Resistance Check

Page 7: Type 8139 data sheet | Radar level meter for liquids ... · The Type 8139 is a non-contact radar level measuring device for continuous level measurement. It is available with: - integrated

Type 8139

7|18Visit product website

4. Dimensions4.1. Plastichornantenna80 mm

Note:Specificationsinmm

8.5 19

986

9

85

129

12

170

ø 80.5

approx. 76

28

123

127

ø 75

ø 107

ø 115

125

2.5

Page 8: Type 8139 data sheet | Radar level meter for liquids ... · The Type 8139 is a non-contact radar level measuring device for continuous level measurement. It is available with: - integrated

Type 8139

8 | 18Visit product website

4.2. Threadwithintegratedantenna40 mm

Note:Specificationsinmm

AF 36

NPT ¾

25

61

ø 24

Version NPT ¾ (ASME B1.20.1)Version G ¾ (DIN 3852-E)

25

61

ø 24

AF 36

G ¾

ø 80.5

approx. 76

123

127

G 1½101

33

ø 42.5

AF 55

Version G 1½ (DIN 3852-E) Version NPT 1½ (ASME B1.20.1)

NPT 1½

AF 55

101

33

ø 42.5

Page 9: Type 8139 data sheet | Radar level meter for liquids ... · The Type 8139 is a non-contact radar level measuring device for continuous level measurement. It is available with: - integrated

Type 8139

9 | 18Visit product website

4.3. Flange with encapsulated antenna system

Note:Specificationsinmm

Version DN50 PN40, up to 130 °C

89

19

4 /

8

20

3

ø45

ø102

24

ø 165

Flange DIN 2501, DN50 PN40 form CBolt circle ø125; 4 x ø18

129

32

3

20

ø 75

ø 158

4 /

8

24

Version DN100 PN16, up to 130 °C

ø 220

Flange DIN 2501, DN50 PN40 form CBolt circle ø180; 8 x ø18

ø 80.5

approx. 76

123

127

Page 10: Type 8139 data sheet | Radar level meter for liquids ... · The Type 8139 is a non-contact radar level measuring device for continuous level measurement. It is available with: - integrated

Type 8139

10 | 18Visit product website

4.4. Hygiene connection with encapsulated antenna system

Note:Specificationsinmm

68.5

16.5

ø 40

ø 51.6

ø 43.8

ø 64

Version clamp 2" PN16, DIN 32676, ISO 2852

5. Performancespecifications5.1. Measurement deviation diagram

Note:ThedrawingshowsthemeasurementdeviationunderreferenceconditionsofType8139withthreadandintegratedhornantenna.This applies accordingly to all versions.

0.25

10

- 10

1- 1 0

[mm]

[m]

Max.

Recommended (depending on version)

Antenna edgeReference plane

Measuring range

Mea

sure

men

t d

evia

tion

Page 11: Type 8139 data sheet | Radar level meter for liquids ... · The Type 8139 is a non-contact radar level measuring device for continuous level measurement. It is available with: - integrated

Type 8139

11 | 18Visit product website

5.2. Temperature derating diagram

Plastichornantenna80 mm

10 20

2030

506070

90

30 40 50 60

Process temperature [°C]

Am

bie

nt t

emp

erat

ure

[°C

]

70

10

-30-20-10

0

40

0-30 -20 -10

80

-40

-40

80

Threadwithintegratedantenna40 mm

10 20

2030

506070

90

30 40 50 60

Process temperature [°C]

Am

bie

nt t

emp

erat

ure

[°C

]

70 80 90 100 110 120

10

-30-20-10

0

40

0

80

130

-40

-40 -30 -20 -10

Flange with encapsulated antenna system

10 20

2030

506070

90

30 40 50 60

Process temperature [°C]

Am

bie

nt t

emp

erat

ure

[°C

]

70 80 90 100 110 120

10

-30-20-10

0

40

0-30 -20 -10

80

-40

-40

130

Page 12: Type 8139 data sheet | Radar level meter for liquids ... · The Type 8139 is a non-contact radar level measuring device for continuous level measurement. It is available with: - integrated

Type 8139

12 | 18Visit product website

6. Product installation6.1. Mounting options

Plastichornantenna80 mmwithmountingbracket

Themountingbracketallowssimplemountingoftheinstrumentonawall,ceilingorboom.Especiallyinthecaseofopenflumes,thisisasimpleandeffectivewaytoalignthesensortothesurfaceoftheliquids.

Mounting bracket - Ceiling mounting Mounting bracket - Wall mountingThe instrument is normally mounted vertically withabracketontheceiling.Thisallowsthesensortoswivelupto180°foroptimalalignmentand rotate for optimal connection.

Alternatively,thebracketcanbemountedhorizontallyordiagonally.

> 200 mm

Plastichornantenna80 mmwithflange

Anadapterflangeisavailableformountingthedeviceonasocket.

AdapterflangeTheadapterflangeisavailablefromDN100.Itispermanentlyconnectedwiththeradarsensorandsealed.

Process seal

Adapter flangeConnection screw

Page 13: Type 8139 data sheet | Radar level meter for liquids ... · The Type 8139 is a non-contact radar level measuring device for continuous level measurement. It is available with: - integrated

Type 8139

13 | 18Visit product website

7. Product operation7.1. Measuring principle

Theradarmeasuringdeviceforthemeasurementofliquidlevelsconsistsofahousingwithelectronicsandaprocessconnectionwithantenna.Theantennaoftheradarsensoremitsacontinuousradarsignal.Thisisreflectedbytheliquidsurfaceandreceivedbytheantennaasanecho.Radarwavespropagateatthespeedoflight.Thefrequencydifferencebetweenthetransmittedandreceivedsignalisproportionaltothedistancetotheliquidsurface.Thefillingleveliscalculatedandconvertedintoacorrespondingoutput signal and transmitted as a measured value.

Themeasuringrangeoftheradarlevelmeasuringdevicebeginsphysicallyattheendoftheantenna.However,themin./max.adjust-mentbeginsatthereferenceplane.Thereferenceplaneisdifferentdependingonthesensorversion.• Plastichornantenna:thereferenceplaneisthesealingsurfaceontheloweredge

• Threadwithintegratedhornantenna:thereferenceplaneisthesealingsurfaceatthebottomofthehexagon

• Flangewithencapsulatedantennasystem:thereferenceplaneistheloweredgeoftheflangeplating

• Hygieneconnectionwithencapsulatedantenna:thereferenceplaneisthehighestcontactpointbetweensensorprocessfittingandweldedsocket

Reference plane

Thread with integrated horn antenna

Flange with encapsulated antenna system

Hygiene connection with encapsulated antenna

Plastic horn antenna 80 mm

Page 14: Type 8139 data sheet | Radar level meter for liquids ... · The Type 8139 is a non-contact radar level measuring device for continuous level measurement. It is available with: - integrated

Type 8139

14 | 18Visit product website

7.2. Product operation notes

Note:Themeasuringdevicecanbeadjustedwith:• thedisplay/configurationmodule

• thesuitableBürkertDTMinconjunctionwithasoftwareaccordingtotheFDT/DTMstandard,e.g.PACTware™andPC

TheenteredparametersaregenerallysavedinthemeasuringdeviceType8139.Optionally,parametersmayalsobeuploadedanddownloadedwiththedisplay/configurationmoduleorsavedinafilebyusingPACTware™/8139-DTM.

Setupwithdisplay/configurationmodule

Display/configurationmodule DescriptionThedisplay/configurationmodulecanbeinsertedintothemeasuringdeviceandremovedagainatanytime.Itisnotnecessarytointerruptthepowersupply.Themeasuringdeviceisadjustedviathefourkeysofthedisplay/configurationmodule.

Set up with PACTware™/DTM and HART communication

Assembly Description

~

=

PACTwareTM

Bürkert DTM

Power supply unit1

2

3

ThemeasuringdevicecanbeoperatedthankstoPACTware™,viaHARTcommunication.AninterfaceadapterisnecessaryfortheadjustmentwithPACTware™.ForthesetupoftheType8139,theDTM in the actual version must be used. The basic version of DTM incl.PACTware™isavailableasafree-of-chargedownloadfromthe internet at www.burkert.com .

Connecting the PC via HARTNo. Description

1 Measuring device Type 81392 HART-USBModem3 Resistance250 Ω

Necessary components:• Measuring device Type 8139

• PCwithPACTware™andsuitableBürkertDTM

• HART-USBModem

• Resistanceapprox.250 Ω

• Powersupplyunit

Page 15: Type 8139 data sheet | Radar level meter for liquids ... · The Type 8139 is a non-contact radar level measuring device for continuous level measurement. It is available with: - integrated

Type 8139

15 | 18Visit product website

8. Product accessoriesNote:Theaccessoriesfortheplastichornantenna80 mmmustbeorderedseparately.

Accessory Description

1252.5

300

9

85

129

12

Mountingbracket300 mm

36.5

20

17.5ø 98

ø 180

ø 220

ø 18 (8 x 45°) AdapterflangeDN100PN16FKM/PPH

36.5

20

17.5ø 98

ø 190.5

ø 228.6

ø 19.1 (8 x 45°) AdapterflangeASME(ANSIB16.5)4"150PSIFKM/PPH

Page 16: Type 8139 data sheet | Radar level meter for liquids ... · The Type 8139 is a non-contact radar level measuring device for continuous level measurement. It is available with: - integrated

Type 8139

16|18Visit product website

9. Ordering information9.1. Bürkert eShop – Easy ordering and quick delivery

Bürkert eShop – Easy ordering and fast delivery

YouwanttofindyourdesiredBürkertproductorsparepartquicklyandorderdirectly?Ouronlineshopisavailableforyou24/7.Signupandenjoyallthebenefits.

Order online now

9.2. Bürkertproductfilter

Bürkertproductfilter–Getquicklytotherightproduct

Youwanttoselectproductscomfortablybasedonyourtechnicalrequirements?UsetheBürkertproductfilterandfindsuitablearticlesforyourapplicationquicklyandeasily.

Tryoutourproductfilter

9.3. Ordering chart

Note:Allfollowingversionsaresuppliedwithoutdisplay/configurationmodule.

Description Operating voltage

Output Process connection

Electrical connection Article no.

Plastichornantenna80 mm 12…35 V DC 4…20 mA/HART (2wires)

Mountingbracket170 mm

Cable gland M20 × 1.5 570592

Threadwithintegratedanten-na40 mm,PN20

12…35 V DC 4…20 mA/HART (2wires)

G ¾ Cable gland M20 × 1.5 570620 NPT ¾ Cable gland M20 × 1.5 570621 G 1½ Cable gland M20 × 1.5 570590 NPT 1½ Cable gland M20 × 1.5 570591

Flangewithencapsulatedantenna system

12…35 V DC 4…20 mA/HART (2wires)

DN50DIN2501,40 bar

Cable gland M20 × 1.5 570606

DN100DIN2501,16 bar

Cable gland M20 × 1.5 570607

Hygieneconnectionwithen-capsulated antenna system

12…35 V DC 4…20 mA/HART (2wires)

Clamp2" Cable gland M20 × 1.5 570605

Further versions on request

Materiale.g.FFKM,PFA

5

bar0

Pressuree.g.1…6 bar,1…10 bar

Process connectione.g.compressionflange,adapterflangeDN150,ANSI,JIS,clamp3"

AdditionalWit display

Temperaturee.g.-40…+200°C

Page 17: Type 8139 data sheet | Radar level meter for liquids ... · The Type 8139 is a non-contact radar level measuring device for continuous level measurement. It is available with: - integrated

Type 8139

17|18Visit product website

9.4. Ordering chart accessories

Description Article no.Setwith2reductionsM20 x 1.5/NPT½+2neopreneflatsealsforcablegland+2screw-plugsM20 x 1.5 551782 Hart-USBModem 560177 Setwithadisplay/configurationmodule,atransparentcoverandasealring 559279 Setwithatransparentcoverandasealring 561006 Mountingbracket300 mm 559839 AdapterflangeDN100PN16FKM/PPH 560437 AdapterflangeASME(ANSIB16.5)4"150PSIFKM/PPH 560436

Page 18: Type 8139 data sheet | Radar level meter for liquids ... · The Type 8139 is a non-contact radar level measuring device for continuous level measurement. It is available with: - integrated

Bürkert – Close to You

AustriaBelgiumCzech Republic DenmarkFinlandFranceGermanyItalyNetherlands

NorwayPoland PortugalSpainSwedenSwitzerlandTurkeyUnited Kingdom

ChinaHong KongIndiaJapan KoreaMalaysiaPhilippinesSingaporeTaiwan

South Africa

Russia

United ArabEmiratesArgentina

BrazilUruguay

CanadaUSA

AustraliaNew Zealand

Credits, © and concept: Christian Bürkert GmbH & Co. KG | Photographs: Marc Eggimann Fotografie - 4051 Basel | Scanner GmbH - Werbeagentur Künzelsau -

74653 Künzelsau

For up-to-date addresses please visit us atwww.burkert.com