GENERAL SANS NOTES: 1. THE DIMENSIONS OF ANY ROOM OR SPACE ARE IN ACCORDANCE WITH THE DETAILED REQUIREMENTS OF SANS 10400-C 2. PUBLIC SAFETY. A CHANGE IN LEVEL, THE DESIGN OF RAMPS AND DRIVEWAYS, OR ACCESS TO SWIMMING POOLS AND SWIMMING BATHS IS IN ACCORDANCE WITH THE DETAILED REQUIREMENTS OF SANS 10400-D 3. SITE OPERATIONS. THE PROVISION OF SANITARY FACILITIES IS IN ACCORDANCE WITH THE DETAILED REQUIREMENTS OF SANS 10400-F 4. THE EXCAVATION RELATING TO A BUILDING IS LESS THAN 3,0M DEEP AND IS IN ACCORDANCE WITH THE DETAILED REQUIREMENTS OF SANS 10400-G 5. THE FOUNDATIONS FOR THE BUILDING TO BE ACCORDING TO SANS 10400-B THE DETAILED REQUIREMENTS OF 6. SANS 10400-H 7. FLOORS IN ANY LAUNDRY, KITCHEN, SHOWER ROOM, BATHROOM OR ROOMS CONTAINING A TOILET PAN OR URINAL TO BE ACCORDING WITH THE DETAILED REQUIREMENTS OF SANS 10400-J 8. THE STRUCTURAL STRENGTH AND STABILITY OF A WALL TO BE ACCORDING WITH SANS 10400-B AND SANS 10400-T. THE DETAILED REQUIREMENTS OF SANS 10400-K. THE ROOF FIXING TO BE ACCORDING WITH SANS 10400-B THE DETAILED REQUIREMENTS OF SANS 10400-K. THE WATER PENETRATION THROUGH A WALL TO BE ACCORDING WITH THE DETAILED REQUIREMENTS OF SANS 10400-K 9. ROOF COVERINGS AND WATERPROOFING SYSTEMS ARE TO BE ACCORDING TO THE DETAILED REQUIREMENTS OF SANS 10400-L THE ROOF ASSEMBLY AND ANY CEILING ASSEMBLY, IN ADDITION TO COMPLY WITH THE REQUIREMENTS OF SANS 10400-C, 10. THE DESIGN OF THE DRAINAGE SYSTEM TO BE ACCORDING WITH THE DETAILED REQUIREMENTS OF SANS 10400-P THE SUBJECT OF A RATIONAL DESIGN OR RATIONAL ASSESSMENT (OR BOTH) THE SUBJECT OF AN AGRÉMENT CERTIFICATE. 11. THE MEANS OF SEWAGE DISPOSAL WHERE WATER-BORNE SEWERAGE DISPOSAL IS NOT AVAILABLE TO BE ACCORDING WITH THE DETAILED 12. REQUIREMENTS OF SANS 10400-Q IS THE SUBJECT OF A RATIONAL DESIGN OR RATIONAL ASSESSMENT (OR BOTH) IS THE SUBJECT OF AN 13. AGRÉMENT CERTIFICATE COMPRISES PAIL CLOSETS WHICH ARE EMPTIED BY OR ON BEHALF OF A LOCAL AUTHORITY. 14. THE MEANS FOR THE CONTROL AND DISPOSAL OF STORM WATER TO BE ACCORDING TO THE DETAILED REQUIREMENTS OF SANS 10400-R THE SUBJECT OF A RATIONAL DESIGN THE MEANS FOR THE CONTROL AND DISPOSAL OF STORM WATER IN INTERCONNECTED 15. COMPLEXES IS THE SUBJECT OF A RATIONAL DESIGN. 16. THE MEANS FOR PROVIDING FACILITIES FOR PERSONS WITH DISABILITIES TO BE ACCORDING TO THE DETAILED REQUIREMENTS OF SANS 10400-S THE SUBJECT OF A RATIONAL DESIGN. 17. THE FIRE PROTECTION MEASURES PROVIDED TO BE ACCORDING TO THE DETAILED REQUIREMENTS OF SANS 10400-T THE SUBJECT OF A RATIONAL DESIGN OR RATIONAL ASSESSMENT. FIRE: ALL THERMAL INSULATION WILL BE IN ACCORDANCE WITH SANS 428. 18. THE PROVISION OF SPACE HEATING TO BE ACCORDING TO THE DETAILED REQUIREMENTS OF SANS 10400-V 19. THE FIRE INSTALLATIONS TO COMPLY WITH THE DETAILED REQUIREMENTS OF SANS 10400-W. THE SUPPLY OF W 20. TO BE ACCORDING TO THE DETAILED REQUIREMENTS OF SANS 10400-L AND THE ROOF ASSEMBLY IS SUPPORTED ON WALLS THAT COMPLY WITH THE REQUIREMENTS OF SANS 10400-K IN ACCORDANCE WITH SANS 10400-B AND SANS 10400-L GUTTERS AND DOWN PIPES, IF ANY, ARE SIZED TO BE ACCORDING TO THE REQUIREMENTS OF SANS 10400-R. THE FIRE RESISTANCE AND COMBUSTIBILITY OF THE ROOF ASSEMBLY OR ANY CEILING ASSEMBLY ARE IN ACCORDANCE WITH THE DETAILED REQUIREMENTS OF SANS 10400-L & SANS 10400-T 21. THE TYPE AND FIXING OF GLAZING TO BE ACCORDING TO SANS 10400-B THE DETAILED REQUIREMENTS OF SANS 10400-N THE SELECTION OF THE GLAZING TO BE ACCORDING TO THE DETAILED REQUIREMENTS OF SANS 10400-N. OBSCURE GLASS TO BATH AND SERVANTS ROOM WINDOW GLASS TO COMPLY WITH NATIONAL BUILDING REG.WS. (PART N) 22. SABS -0137 AND -1263 23. THE LIGHTING IN A HABITABLE ROOM, BATHROOM, SHOWER ROOM AND ROOM CONTAINING A TOILET PAN COMPLIES WITH THE REQUIREMENTS OF SANS 10400-T AND THE DETAILED REQUIREMENTS OF SANS 10400-O THE VENTILATION TO BE ACCORDING TO THE REQUIREMENTS OF SANS 10400-T AND TO BE ACCORDING TO THE DETAILED REQUIREMENTS OF SANS 10400-O IS THE SUBJECT OF A RATIONAL DESIGN. LIGHT AND VENTILATION ACCORDING TO NEW NATIONAL BUILDING REG. (PART O) . INTERNAL LIGHTING: ALL LIGHTING IN A DWELLING WILL COMPLY WITH SANS 10114-1 AND SANS 204 24. MAXIMUM USAGE OF 5W/S. INTERNAL LIGHTING: ALL LIGHTING IN A DWELLING WILL COMPLY WITH SANS 10114-1 AND SANS 204 MAXIMUM USAGE OF 5W/SQM 25. THE DESIGN OF THE DRAINAGE SYSTEM TO BE ACCORDING WITH THE DETAILED REQUIREMENTS OF SANS 10400-P THE SUBJECT OF A RATIONAL DESIGN OR RATIONAL ASSESSMENT (OR BOTH) THE SUBJECT OF AN AGRÉMENT CERTIFICATE. 26. THE MEANS OF SEWAGE DISPOSAL WHERE WATER-BORNE SEWERAGE DISPOSAL IS NOT AVAILABLE TO BE ACCORDING WITH THE DETAILED REQUIREMENTS OF SANS 10400-Q IS THE SUBJECT OF A RATIONAL DESIGN OR RATIONAL ASSESSMENT (OR BOTH) IS THE SUBJECT OF AN AGRÉMENT CERTIFICATE COMPRISES PAIL CLOSETS WHICH ARE EMPTIED BY OR ON BEHALF OF A LOCAL AUTHORITY. 27. THE MEANS FOR THE CONTROL AND DISPOSAL OF STORM WATER TO BE ACCORDING TO THE DETAILED REQUIREMENTS OF SANS 10400-R THE SUBJECT OF A RATIONAL DESIGN THE MEANS FOR THE CONTROL AND DISPOSAL OF STORM WATER IN INTERCONNECTED 28. COMPLEXES IS THE SUBJECT OF A RATIONAL DESIGN. 29. THE MEANS FOR PROVIDING FACILITIES FOR PERSONS WITH DISABILITIES TO BE ACCORDING TO THE DETAILED REQUIREMENTS OF SANS 10400-S THE SUBJECT OF A RATIONAL DESIGN. 30. THE FIRE PROTECTION MEASURES PROVIDED TO BE ACCORDING TO THE DETAILED REQUIREMENTS OF SANS 10400-T THE SUBJECT OF A RATIONAL DESIGN OR RATIONAL ASSESSMENT. FIRE: ALL THERMAL INSULATION WILL BE IN ACCORDANCE WITH SANS 428. 31. THE PROVISION OF SPACE HEATING TO BE ACCORDING TO THE DETAILED REQUIREMENTS OF SANS 10400-V 32. THE FIRE INSTALLATIONS TO COMPLY WITH THE DETAILED REQUIREMENTS OF SANS 10400-W. THE SUPPLY OF WATER TO BE ACCORDING TO THE DETAILED REQUIREMENTS OF SANS 10400-W THE SUBJECT OF A RATIONAL DESIGN. TYPE 1 Electrical Layout Ground Floor Plan Scale 1:100 A/C A/C TYPE 1 Electrical Layout First Floor Plan Scale 1:100 PROJECT: DRAWING DESCRIPTION: SCALE: REVISION: DRAWING NO.: PROJECT NO.: DATE: DRAWN: CC 24/07/2017 216-99 See plan 00 102 ARCHITECTS NOTES ALL MATERIALS AND CONSTRUCTION MUST COMPLY WITH NATIONAL BUILDING REGULATIONS ACT NO. 103 OF 1997. INCLUDING ALL AMENDMENTS AS WELL AS THE BY-LAWS OF THE LOCAL AUTHORITIES. ALL DIMENSIONS AND LEVELS TO BE CHECKED ON SITE AND NO DRAWINGS MUST BE SCALED. ANY INDISTINCTNESS OR DISCREPANCIES MUST BE IMMEDIATELY POINTED OUT TO THE ARCHITECT FOR RECTIFICATION OR EXPLANATION BEFORE ANY CONSTRUCTION CAN COMMENCE. ALL PLANS ARE PROTECTED BY THE COPYRIGHT ACT NO. 98 OF 1978. ENERGY EFFICIENT MEASURES TO BE TAKEN BY CLIENT. ALL LIGHTS TO BE FITTED WITH ENERGY EFFICIENT FITTINGS. ALL WESTERN WINDOWS TO BE SHADED WITH TREES. WATER SAVING SHOWER HEADS TO BE FITTED. TOILETS TO BE WITH WATER SAVING FLUSH CONTROL. ENERGY EFFICIENCY TO BE TAKEN IN BUILDING TO COMPLY WITH PART XA. MIN 50% OF HOT WATER REQUIRED TO BE SUPPLIED BY HEAT PUMP OR SOLAR. ALL EXPOSED HOT WATER TO INSULATED WITH A "R' VALUE OF 1 ROOF OVERHANG 400mm. ROOF ASSEMBLIES TO ACHIEVE A "R" OF 32 WALLS TO BE 230 BRICK PLASTERED BOTH SIDES, WATER TO BE SLOPED AWAY FROM BUILDING. ALL STRUCTURAL WORK TO COMPLY WITH KK5 OF SANS 10400 AND 0401 THE CONTRACTOR ON SITE MUST MAKE SURE THAT THE LEVEL BETWEEN THE HOUSE AND GARAGE IS SO THAT A CAR CAN ENTER THE GARAGE WITH EASE. ALL TIMBER TO BE TREATED ACCORDING TO SABS 1288 STANDARD. ALL FINISHED FLOOR LEVELS ARE TO BE DETERMINED ON SITE AFTER SETTING OUT THE COMPLETED PROJECT. IT IS THE RESPONSIBILITY OF THE OWNER AND OR SUBCONTRACTOR OR CONTRACTOR TO CHECK ALL DIMENSIONS, AREAS, LEVELS AND SITE BOUNDARIES BEFORE COMMENCEMENT OF THE WORK ON SITE, ANY DISCREPANCY SHOULD BE REPORTED TO THIS OFFICE AT ONCE. ANY DISCREPANCY BETWEEN PLANS, SPECIFICATION AND QUOTATION SHOULD BE REPORTED TO THIS OFFICE AT ONCE. ANY REVISIONS AND OR CHANGES DONE ON SITE MUST BE REPORTED TO THIS OFFICE AT ONCE. NO WORK ON SITE SHALL COMMENCE BEFORE PLANS ARE APPROVED BY THE LOCAL AUTHORITY AND SUCH APPROVAL IS IN THE POSSESSION OF THE CONTRACTOR. IT SHALL BE DETERMINED ON SITE BY THE CONTRACTOR IF THE GROUND SHALL NEED TO BE INSPECTED BY A ENG TO DETERMINE IF REINFORCING ARE NEEDED IN THE FOUNDATIONS. ANY CONTRACTOR AND OR SUB-CONTRACTOR SHALL AT ALL TIMES MAKE SURE THAT ANY MATERIAL USED ON SITE SHALL BE SUITABLE FOR THE USE THEREOF AND INSTALLED STRICTLY IN ACCORDANCE WITH THE MANUFACTURERS SPECIFICATION. Proposed Townhouses Periculum Property Invest Pty Ltd Erf 538 49 Lynnwood Road Lynnwood Manor _________________________ Client Signature _________________________ Draughtsperson Signature Corlea Cloete SACAP : 21044 A R C H I T E C T S 67 BRINK STREET TEL.014 5921960 FAX.086 617 7275 P.O. BOX 1360, RUSTENBURG GAIL ARCHITECTS @ OFFICE OFFICE 25 COUNCIL 350 maks. max. 150 gulley cleaning eye concrete casing inspection eye this detail applicable where drain depth exceeds 600. GULLEY DETAIL TYPE 1: Energy Efficiency Electrical Layout ELECTRICAL NOTES: ALL PLUG POINTS UNLESS SPECIFIED BE 300mm OFF GROUND LEVEL. ALL PLUG POINTS IN KITCHENS TO BE 1100mm OFF GROUND LEVEL. ALL PLUG POINTS IN BATHROOMS TO BE 1300mm OFF GROUND LEVEL. ALL OUT-SIDE LIGHTS TO WORK OFF A DAY-NIGHT SWITCH. ALL AIR CONDITIONING POINTS AND SUPPLY TO BE CHECKED BE FOR POINTS ARE INSTALLED WITH AIR CONDITIONING CONTRACTOR. ELECTRICAL SUPPLY WILL BE 3ph.FROM MUNICIPAL. Energy sawing spot light - 9watt LED fluorescent light fitting - 15watt Estimate Maximum Demand 1060 Watt Maximum Demand AS / SANS 10142 1820HRS / a Estimate Annual Energy Consumption 440.44 KW / a Energy Consumption 2.08 KW Conclusion: The Design Complies With The Requirement Of SANS 10400-XA:2011 For Energy Consumption Total For New Building 176 watt 16 16 x 4 Watt 64 Watt Globe / Type Symb. Q Total watt Calculations 4 4 x 9 Watt 36 Watt 2 2 x 15 Watt 60 Watt LED energy saving ceiling light fitting- 9watt LED downlighter - 4 watt 8 8 x 2 Watt 16 Watt Two-way light switch Light switch 1 500 LED double fluorescent tube light Outside LED Waterproof wall light. Day/Night switch Television point 150liter 4Kw geyser Connection Distribution board LED ceiling light fitting- 9 watt Double 16 amp power outlet Electrical Legend Air Conditoning A/C Extractor Fan Small LED downlighter 2 watt Extractor Fan SANS 10400 - Ceiling extractor fan to be installed in all bathrooms / toilets / storage areas / garages with no window to regulate of ventilation 300x300mm extractor fan to be used that covers up to 329m² installation to be done by certified electrician.

Transcript of TYPE 1 Electrical Layout Ground Floor...

GENERAL SANS NOTES:

1. THE DIMENSIONS OF ANY ROOM OR SPACE ARE IN ACCORDANCE WITH THEDETAILED REQUIREMENTS OF SANS 10400-C

2. PUBLIC SAFETY. A CHANGE IN LEVEL, THE DESIGN OF RAMPS ANDDRIVEWAYS, OR ACCESS TO SWIMMING POOLS AND SWIMMING BATHS IS INACCORDANCE WITH THE DETAILED REQUIREMENTS OF SANS 10400-D

3. SITE OPERATIONS. THE PROVISION OF SANITARY FACILITIES IS INACCORDANCE WITH THE DETAILED REQUIREMENTS OF SANS 10400-F

4. THE EXCAVATION RELATING TO A BUILDING IS LESS THAN 3,0M DEEP AND IS INACCORDANCE WITH THE DETAILED REQUIREMENTS OF SANS 10400-G

5. THE FOUNDATIONS FOR THE BUILDING TO BE ACCORDING TO SANS 10400-BTHE DETAILED REQUIREMENTS OF

6. SANS 10400-H7. FLOORS IN ANY LAUNDRY, KITCHEN, SHOWER ROOM, BATHROOM OR ROOMS

CONTAINING A TOILET PAN OR URINAL TO BE ACCORDING WITH THE DETAILEDREQUIREMENTS OF SANS 10400-J

8. THE STRUCTURAL STRENGTH AND STABILITY OF A WALL TO BE ACCORDINGWITH SANS 10400-B AND SANS 10400-T. THE DETAILED REQUIREMENTS OFSANS 10400-K. THE ROOF FIXING TO BE ACCORDING WITH SANS 10400-B THEDETAILED REQUIREMENTS OF SANS 10400-K. THE WATER PENETRATIONTHROUGH A WALL TO BE ACCORDING WITH THE DETAILED REQUIREMENTS OFSANS 10400-K

9. ROOF COVERINGS AND WATERPROOFING SYSTEMS ARE TO BE ACCORDINGTO THE DETAILED REQUIREMENTS OF SANS 10400-L THE ROOF ASSEMBLYAND ANY CEILING ASSEMBLY, IN ADDITION TO COMPLY WITH THEREQUIREMENTS OF SANS 10400-C,

10. THE DESIGN OF THE DRAINAGE SYSTEM TO BE ACCORDING WITH THEDETAILED REQUIREMENTS OF SANS 10400-P THE SUBJECT OF A RATIONALDESIGN OR RATIONAL ASSESSMENT (OR BOTH) THE SUBJECT OF ANAGRÉMENT CERTIFICATE.

11. THE MEANS OF SEWAGE DISPOSAL WHERE WATER-BORNE SEWERAGEDISPOSAL IS NOT AVAILABLE TO BE ACCORDING WITH THE DETAILED

12. REQUIREMENTS OF SANS 10400-Q IS THE SUBJECT OF A RATIONAL DESIGN ORRATIONAL ASSESSMENT (OR BOTH) IS THE SUBJECT OF AN

13. AGRÉMENT CERTIFICATE COMPRISES PAIL CLOSETS WHICH ARE EMPTIED BYOR ON BEHALF OF A LOCAL AUTHORITY.

14. THE MEANS FOR THE CONTROL AND DISPOSAL OF STORM WATER TO BEACCORDING TO THE DETAILED REQUIREMENTS OF SANS 10400-R THESUBJECT OF A RATIONAL DESIGN THE MEANS FOR THE CONTROL ANDDISPOSAL OF STORM WATER IN INTERCONNECTED

15. COMPLEXES IS THE SUBJECT OF A RATIONAL DESIGN.16. THE MEANS FOR PROVIDING FACILITIES FOR PERSONS WITH DISABILITIES TO

BE ACCORDING TO THE DETAILED REQUIREMENTS OF SANS 10400-S THESUBJECT OF A RATIONAL DESIGN.

17. THE FIRE PROTECTION MEASURES PROVIDED TO BE ACCORDING TO THEDETAILED REQUIREMENTS OF SANS 10400-T THE SUBJECT OF A RATIONALDESIGN OR RATIONAL ASSESSMENT. FIRE: ALL THERMAL INSULATION WILLBE IN ACCORDANCE WITH SANS 428.

18. THE PROVISION OF SPACE HEATING TO BE ACCORDING TO THE DETAILEDREQUIREMENTS OF SANS 10400-V

19. THE FIRE INSTALLATIONS TO COMPLY WITH THE DETAILED REQUIREMENTSOF SANS 10400-W. THE SUPPLY OF W

20. TO BE ACCORDING TO THE DETAILED REQUIREMENTS OF SANS 10400-L ANDTHE ROOF ASSEMBLY IS SUPPORTED ON WALLS THAT COMPLY WITH THEREQUIREMENTS OF SANS 10400-K IN ACCORDANCE WITH SANS 10400-B ANDSANS 10400-L GUTTERS AND DOWN PIPES, IF ANY, ARE SIZED TO BEACCORDING TO THE REQUIREMENTS OF SANS 10400-R. THE FIRE RESISTANCEAND COMBUSTIBILITY OF THE ROOF ASSEMBLY OR ANY CEILING ASSEMBLYARE IN ACCORDANCE WITH THE DETAILED REQUIREMENTS OF SANS 10400-L &SANS 10400-T

21. THE TYPE AND FIXING OF GLAZING TO BE ACCORDING TO SANS 10400-B THEDETAILED REQUIREMENTS OF SANS 10400-N THE SELECTION OF THE GLAZINGTO BE ACCORDING TO THE DETAILED REQUIREMENTS OF SANS 10400-N.OBSCURE GLASS TO BATH AND SERVANTS ROOM WINDOW GLASS TO COMPLYWITH NATIONAL BUILDING REG.WS. (PART N)

22. SABS -0137 AND -126323. THE LIGHTING IN A HABITABLE ROOM, BATHROOM, SHOWER ROOM AND ROOM

CONTAINING A TOILET PAN COMPLIES WITH THE REQUIREMENTS OFSANS 10400-T AND THE DETAILED REQUIREMENTS OF SANS 10400-O THEVENTILATION TO BE ACCORDING TO THE REQUIREMENTS OF SANS 10400-TAND TO BE ACCORDING TO THE DETAILED REQUIREMENTS OF SANS 10400-OIS THE SUBJECT OF A RATIONAL DESIGN. LIGHT AND VENTILATION ACCORDINGTO NEW NATIONAL BUILDING REG. (PART O) . INTERNAL LIGHTING: ALLLIGHTING IN A DWELLING WILL COMPLY WITH SANS 10114-1 AND SANS 204

24. MAXIMUM USAGE OF 5W/S. INTERNAL LIGHTING: ALL LIGHTING IN A DWELLINGWILL COMPLY WITH SANS 10114-1 AND SANS 204 MAXIMUM USAGE OF 5W/SQM

25. THE DESIGN OF THE DRAINAGE SYSTEM TO BE ACCORDING WITH THEDETAILED REQUIREMENTS OF SANS 10400-P THE SUBJECT OF A RATIONALDESIGN OR RATIONAL ASSESSMENT (OR BOTH) THE SUBJECT OF ANAGRÉMENT CERTIFICATE.

26. THE MEANS OF SEWAGE DISPOSAL WHERE WATER-BORNE SEWERAGEDISPOSAL IS NOT AVAILABLE TO BE ACCORDING WITH THE DETAILEDREQUIREMENTS OF SANS 10400-Q IS THE SUBJECT OF A RATIONAL DESIGN ORRATIONAL ASSESSMENT (OR BOTH) IS THE SUBJECT OF AN AGRÉMENTCERTIFICATE COMPRISES PAIL CLOSETS WHICH ARE EMPTIED BY OR ONBEHALF OF A LOCAL AUTHORITY.

27. THE MEANS FOR THE CONTROL AND DISPOSAL OF STORM WATER TO BEACCORDING TO THE DETAILED REQUIREMENTS OF SANS 10400-R THESUBJECT OF A RATIONAL DESIGN THE MEANS FOR THE CONTROL ANDDISPOSAL OF STORM WATER IN INTERCONNECTED

28. COMPLEXES IS THE SUBJECT OF A RATIONAL DESIGN.29. THE MEANS FOR PROVIDING FACILITIES FOR PERSONS WITH DISABILITIES TO

BE ACCORDING TO THE DETAILED REQUIREMENTS OF SANS 10400-S THESUBJECT OF A RATIONAL DESIGN.

30. THE FIRE PROTECTION MEASURES PROVIDED TO BE ACCORDING TO THEDETAILED REQUIREMENTS OF SANS 10400-T THE SUBJECT OF A RATIONALDESIGN OR RATIONAL ASSESSMENT. FIRE: ALL THERMAL INSULATION WILLBE IN ACCORDANCE WITH SANS 428.

31. THE PROVISION OF SPACE HEATING TO BE ACCORDING TO THE DETAILEDREQUIREMENTS OF SANS 10400-V

32. THE FIRE INSTALLATIONS TO COMPLY WITH THE DETAILED REQUIREMENTSOF SANS 10400-W. THE SUPPLY OF WATER TO BE ACCORDING TO THEDETAILED REQUIREMENTS OF SANS 10400-W THE SUBJECT OF A RATIONALDESIGN.

TYPE 1Electrical LayoutGround Floor PlanScale 1:100

A/CA/C

TYPE 1Electrical LayoutFirst Floor PlanScale 1:100

PROJECT:

DRAWING DESCRIPTION:

SCALE:

REVISION:

DRAWING NO.:PROJECT NO.:

DATE:

DRAWN:CC

24/07/2017

216-99

See plan

00

102

ARCHITECTS NOTES

ALL MATERIALS AND CONSTRUCTION MUST COMPLYWITH NATIONAL BUILDING REGULATIONS ACT NO. 103 OF1997. INCLUDING ALL AMENDMENTS AS WELL AS THEBY-LAWS OF THE LOCAL AUTHORITIES. ALL DIMENSIONSAND LEVELS TO BE CHECKED ON SITE AND NODRAWINGS MUST BE SCALED. ANY INDISTINCTNESS ORDISCREPANCIES MUST BE IMMEDIATELY POINTED OUT TOTHE ARCHITECT FOR RECTIFICATION OR EXPLANATIONBEFORE ANY CONSTRUCTION CAN COMMENCE. ALLPLANS ARE PROTECTED BY THE COPYRIGHT ACT NO. 98OF 1978.

ENERGY EFFICIENT MEASURES TO BE TAKEN BY CLIENT.ALL LIGHTS TO BE FITTED WITH ENERGY EFFICIENTFITTINGS. ALL WESTERN WINDOWS TO BE SHADED WITHTREES. WATER SAVING SHOWER HEADS TO BE FITTED.TOILETS TO BE WITH WATER SAVING FLUSH CONTROL.ENERGY EFFICIENCY TO BE TAKEN IN BUILDING TOCOMPLY WITH PART XA. MIN 50% OF HOT WATERREQUIRED TO BE SUPPLIED BY HEAT PUMP OR SOLAR.ALL EXPOSED HOT WATER TO INSULATED WITH A "R'VALUE OF 1 ROOF OVERHANG 400mm. ROOF ASSEMBLIESTO ACHIEVE A "R" OF 32 WALLS TO BE 230 BRICKPLASTERED BOTH SIDES, WATER TO BE SLOPED AWAYFROM BUILDING. ALL STRUCTURAL WORK TO COMPLYWITH KK5 OF SANS 10400 AND 0401 THE CONTRACTOR ONSITE MUST MAKE SURE THAT THE LEVEL BETWEEN THEHOUSE AND GARAGE IS SO THAT A CAR CAN ENTER THEGARAGE WITH EASE. ALL TIMBER TO BE TREATEDACCORDING TO SABS 1288 STANDARD. ALL FINISHEDFLOOR LEVELS ARE TO BE DETERMINED ON SITE AFTERSETTING OUT THE COMPLETED PROJECT. IT IS THERESPONSIBILITY OF THE OWNER AND ORSUBCONTRACTOR OR CONTRACTOR TO CHECK ALLDIMENSIONS, AREAS, LEVELS AND SITE BOUNDARIESBEFORE COMMENCEMENT OF THE WORK ON SITE, ANYDISCREPANCY SHOULD BE REPORTED TO THIS OFFICEAT ONCE. ANY DISCREPANCY BETWEEN PLANS,SPECIFICATION AND QUOTATION SHOULD BE REPORTEDTO THIS OFFICE AT ONCE. ANY REVISIONS AND ORCHANGES DONE ON SITE MUST BE REPORTED TO THISOFFICE AT ONCE. NO WORK ON SITE SHALL COMMENCEBEFORE PLANS ARE APPROVED BY THE LOCALAUTHORITY AND SUCH APPROVAL IS IN THE POSSESSIONOF THE CONTRACTOR. IT SHALL BE DETERMINED ON SITEBY THE CONTRACTOR IF THE GROUND SHALL NEEDTO BE INSPECTED BY A ENG TO DETERMINE IFREINFORCING ARE NEEDED IN THE FOUNDATIONS. ANYCONTRACTOR AND OR SUB-CONTRACTOR SHALL AT ALLTIMES MAKE SURE THAT ANY MATERIAL USED ON SITESHALL BE SUITABLE FOR THE USE THEREOF ANDINSTALLED STRICTLY IN ACCORDANCE WITH THEMANUFACTURERS SPECIFICATION.

Proposed TownhousesPericulum Property Invest Pty Ltd

Erf 53849 Lynnwood RoadLynnwood Manor

_________________________Client Signature

_________________________Draughtsperson SignatureCorlea Cloete

SACAP : 21044

A R C H I T E C T S

67 BRINK STREET

TEL.014 5921960 FAX.086 617 7275

P.O. BOX 1360, RUSTENBURG

GAIL ARCHITECTS

@ OFFICE

OFFICE 25

COUNCIL

350 m

aks.

m

ax.

150

gulley

cleaning eye

concrete casing

inspection eye

this detail applicable where

drain depth exceeds 600.

GULLEY DETAIL

TYPE 1:Energy EfficiencyElectrical LayoutELECTRICAL NOTES:

ALL PLUG POINTS UNLESS SPECIFIED BE300mm OFF GROUND LEVEL. ALL PLUGPOINTS IN KITCHENS TO BE 1100mm OFFGROUND LEVEL. ALL PLUG POINTS INBATHROOMS TO BE 1300mm OFF GROUNDLEVEL. ALL OUT-SIDE LIGHTS TO WORKOFF A DAY-NIGHT SWITCH.ALL AIR CONDITIONING POINTS ANDSUPPLY TO BE CHECKED BE FOR POINTSARE INSTALLED WITH AIR CONDITIONINGCONTRACTOR. ELECTRICAL SUPPLY WILLBE 3ph.FROM MUNICIPAL.

Energy sawing spot light - 9watt

LED fluorescent light fitting - 15watt

Estimate Maximum Demand 1060 Watt

Maximum Demand AS / SANS 10142 1820HRS / a

Estimate Annual Energy Consumption 440.44 KW / a

Energy Consumption 2.08 KW

Conclusion:

The Design Complies With The Requirement Of

SANS 10400-XA:2011 For Energy Consumption

Total For New Building

176 watt

16 16 x 4 Watt 64 Watt

Globe / TypeSymb. Q

Total wattCalculations

4 4 x 9 Watt 36 Watt

2 2 x 15 Watt 60 Watt

LED energy saving ceiling light fitting- 9watt

LED downlighter - 4 watt8 8 x 2 Watt 16 Watt

Two-way light switch

Light switch

1 500 LED double fluorescent tube light

Outside LED Waterproof wall light. Day/Night switch

Television point

150liter 4Kw geyser Connection

Distribution board

LED ceiling light fitting- 9 watt

Double 16 amp power outlet

Electrical Legend

Air ConditoningA/C

Extractor Fan

Small LED downlighter 2 watt

Extractor FanSANS 10400 - Ceiling extractor fan to beinstalled in all bathrooms / toilets / storageareas / garages with no window to regulateof ventilation 300x300mm extractor fan to beused that covers up to 329m² installation tobe done by certified electrician.