PRODUCT GUIDE LFII Residential Sprinklers Sprinkler System Components CPVC Pipe & Fittings

description

Guia para aplicação de chuveiros automáticos de resposta e supressão rápidas

Transcript of Tyco Fire Rapid Response Product Guide_5 2015

Page 1: Tyco Fire Rapid Response Product Guide_5 2015

PRODUCT GUIDE

LFII Residential Sprinklers

Sprinkler System Components

CPVC Pipe & Fittings

Page 2: Tyco Fire Rapid Response Product Guide_5 2015

Rapid Response™ Residential Fire Sprinkler Systems

•   Developed specifically for residential occupancies

•   The most complete system on the market today from a single manufacturer

•   Features BlazeMaster® CPVC pipe and fittings, making installation quick, easy, flexible, and affordable

•   Exclusive ten-year limited warranty lets you install with confidence

•  Product line meets all NFPA standards

•   Components are all UL listed for residential installations

Table of Contents

Series LFII Sprinklers ..............................................................................4-8

Series LFII Dry Sprinklers...........................................................................9

Series LFII NFPA 13 Optimized Sprinklers ......................................................................... 10-13

System Components .........................................................................14-15

CPVC Pipe and Fittings .....................................................................16-17

Page 3: Tyco Fire Rapid Response Product Guide_5 2015

Rapid Response™ Residential Fire Sprinkler Systems

•   Developed specifically for residential occupancies

•   The most complete system on the market today from a single manufacturer

•   Features BlazeMaster® CPVC pipe and fittings, making installation quick, easy, flexible, and affordable

•   Exclusive ten-year limited warranty lets you install with confidence

•  Product line meets all NFPA standards

•   Components are all UL listed for residential installations

Table of Contents

Series LFII Sprinklers ..............................................................................4-8

Series LFII Dry Sprinklers...........................................................................9

Series LFII NFPA 13 Optimized Sprinklers ......................................................................... 10-13

System Components .........................................................................14-15

CPVC Pipe and Fittings .....................................................................16-17

Page 4: Tyco Fire Rapid Response Product Guide_5 2015

• Fast response

• Used in wet pipe residential sprinkler systems for one-and two-family dwellings and mobile homes per NFPA 13D

• Used in wet pipe sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R

K Factor K=3.0 (43,2)

Thread Size 1/2” (15 mm)

Bulb Type 3 mm

Finish White, Chrome, Brass

Tech Data TFP402

MAXIMUM COVERAGE AREA

ft x ft (m x m)

MAXIMUM SPACING

ft (m)

MINIMUM FLOW & RESIDUAL PRESSURE For Horizontal Ceiling (Max. 2” rise for 12” run)

155°F/68°C or 175°F/79°C

12 x 12 (3,7 x 3,7)

12 (3,7)

13 GPM (49,2 LPM) 7.0 psi (0,48 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

13 GPM (49,2 LPM) 7.0 psi (0,48 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

13 GPM (49,2 LPM)7.0 psi (0,48 bar)

18 x 18 (5,5 x 5,5)

18 (5,5)

17 GPM (64,3 LPM) 12.0 psi (0,83 bar)

20 x 20 (6,1 x 6,1)

20 (6,1)

20 GPM (75,7 LPM) 16.7 psi (1,15 bar)

MAXIMUM COVERAGE AREA

ft x ft (m x m)

MAXIMUM SPACING

ft (m)

MINIMUM FLOW & RESIDUAL PRESSURE For Horizontal Ceiling (Max. 2” rise for 12” run)

155°F/68°C or 175°F/79°C

12 x 12 (3,7 x 3,7)

12 (3,7)

8 GPM (30,3 LPM) 7.1 psi (0,49 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

11 GPM (41,6 LPM) 13.4 psi (0,92 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

13 GPM (49,2 LPM)18.8 psi (1,29 bar)

MAXIMUM COVERAGE AREA

MAXIMUM SPACING MINIMUM FLOW & RESIDUAL PRESSURE

ft x ft (m x m) ft (m) 4” – 6” (100 mm – 150 mm) below ceiling 6” – 12” (150 mm – 300 mm) below ceiling

155°F/68°C 175°F/79°C 155°F/68°C 175°F/79°C

12 x 12 (3,7 x 3,7)

12 (3,7)

12 GPM (45,4 LPM) 8.2 psi (0,57 bar)

12 GPM (45,4 LPM) 8.2 psi (0,57 bar)

13 GPM (49,2 LPM) 9.6 psi (0,48 bar)

13 GPM (49,2 LPM) 9.6 psi (0,48 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

14 GPM (53,0 LPM) 11.1 psi (0,77 bar)

16 GPM (60,6 LPM)14.5 psi (1,00 bar)

17 GPM (64, 3 LPM) 16.4 psi (1,13 bar)

18 GPM (68,1 LPM) 18.4 psi (1,27 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

16 GPM (60,6 LPM)14.5 psi (1,00 bar)

16 GPM (60,6 LPM)14.5 psi (1,00 bar)

18 GPM (68,1 LPM) 18.4 psi (1,27 bar)

18 GPM (68,1 LPM) 18.4 psi (1,27 bar)

16 x 18 (4,9 x 5,5)

16 (4,9)

19 GPM (71,9 LPM) 20.5 psi (1,41 bar)

19 GPM (71,9 LPM) 20.5 psi (1,41 bar)

21 GPM (79,5 LPM) 25.0 psi (1,72 bar)

21 GPM (79,5 LPM) 25.0 psi (1,72 bar)

16 x 20 (4,9 x 6,1)

16 (4,9)

23 GPM (87,1 LPM) 30.0 psi (2,07 bar)

19 GPM (71,9 LPM) 20.5 psi (1,41 bar)

26 GPM (98,4 LPM) 38.3 psi (2,64 bar)

26 GPM (98,4 LPM) 38.3 psi (2,64 bar)

MAXIMUM COVERAGE AREA

MAXIMUM SPACING MINIMUM FLOW & RESIDUAL PRESSURE

ft x ft (m x m) ft (m) 4” – 6” (100 mm – 150 mm) below ceiling 6” – 12” (150 mm – 300 mm) top of deflector to ceiling

155°F/68°C 175°F/79°C 155°F/68°C 175°F/79°C

12 x 12 (3,7 x 3,7)

12 (3,7)

13 GPM (49,2 LPM) 8.7 psi (0,60 bar)

13 GPM (49,2 LPM) 8.7 psi (0,60 bar)

13 GPM (49,2 LPM) 8.7 psi (0,60 bar)

13 GPM (49,2 LPM) 8.7 psi (0,60 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

14 GPM (53,0 LPM) 10.1 psi (0,70 bar)

14 GPM (53,0 LPM) 10.1 psi (0,70 bar)

14 GPM (53,0 LPM) 10.1 psi (0,70 bar)

14 GPM (53,0 LPM) 10.1 psi (0,70 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

16 GPM (60,6 LPM)13.2 psi (0,91 bar)

16 GPM (60,6 LPM)13.2 psi (0,91 bar)

17 GPM (64,3 LPM) 14.9 psi (1,03 bar)

17 GPM (64,3 LPM) 14.9 psi (1,03 bar)

16 x 18 (4,9 x 5,5)

16 (4,9)

19 GPM (71,9 LPM) 18.6 psi (1,28 bar)

19 GPM (71,9 LPM) 18.6 psi (1,28 bar)

20 GPM (75.7 LPM) 20.7 psi (1,43 bar)

20 GPM (75.7 LPM) 20.7 psi (1,43 bar)

16 x 20 (4,9 x 6,1)

16 (4,9)

23 GPM (87,1 LPM) 27.3 psi (1,88 bar)

23 GPM (87,1 LPM) 27.3 psi (1,88 bar)

23 GPM (87,1 LPM) 27.3 psi (1,88 bar)

23 GPM (87,1 LPM) 27.3 psi (1,88 bar)

18 x 18 (5,5 x 5,5)

18 (5,5)

23 GPM (87,1 LPM) 27.3 psi (1,88 bar)

23 GPM (87,1 LPM) 27.3 psi (1,88 bar)

23 GPM (87,1 LPM) 27.3 psi (1,88 bar)

23 GPM (87,1 LPM) 27.3 psi (1,88 bar)

18 x 20 (5,5 x 6,1)

18 (5,5)

26 GPM (98,4 LPM) 34.9 psi (2,41 bar)

26 GPM (98,4 LPM) 34.9 psi (2,41 bar)

26 GPM (98,4 LPM) 34.9 psi (2,41 bar)

26 GPM (98,4 LPM) 34.9 psi (2,41 bar)

• Fast response

• Used in wet pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D

• Used in wet pipe residential occupancies up to and including four stories in height per NFPA 13R

• Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

• Fast response

• Used in wet pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D

• Used in wet pipe residential occupancies up to and including four stories in height per NFPA 13R

• Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

K Factor K=4.2 (60,5)

Thread Size 1/2” (15 mm)

Escutcheon Style 20

Bulb Type 3 mm

Finish White, Chrome, Brass

Tech Data TFP410

K Factor K=4.4 (63,4)

Thread Size 1/2” (15 mm)

Escutcheon Style 20

Bulb Type 3 mm

Finish White, Chrome, Brass

Tech Data TFP412

LFII (TY2234) Pendent, Recessed Pendent and Domed Concealed

LFII (TY1234) Pendent and Recessed Pendent LFII (TY2334) Horizontal and Recessed Horizontal Sidewall

LFII (TY1334) Horizontal and Recessed Horizontal Sidewall

Always refer to the technical data sheet for complete description and all listing criteria, design parameters, installation instructions, care and maintenance guidelines and our limited warranty.

Series LFII Sprinklers

• Fast response

• Approved for special applications with beamed ceilings

• Used in wet pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D

• Used in wet pipe residential occupancies up to and including four stories in height per NFPA 13R

• Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

K Factor K=4.9 (70,6)

Thread Size 1/2” (15 mm)

Escutcheon Style 20

Bulb Type 3 mm

Finish White, Chrome, Brass, Custom

Tech Data TFP400 (TFP450 Domed Concealed)

We can match any Sherwin Williams color for Flat Plate and Domed Concealed sprinklers you install. See the cover plate chart on page 7 for standard colors and finishes.

Page 5: Tyco Fire Rapid Response Product Guide_5 2015

• Fast response

• Used in wet pipe residential sprinkler systems for one-and two-family dwellings and mobile homes per NFPA 13D

• Used in wet pipe sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R

K Factor K=3.0 (43,2)

Thread Size 1/2” (15 mm)

Bulb Type 3 mm

Finish White, Chrome, Brass

Tech Data TFP402

MAXIMUM COVERAGE AREA

ft x ft (m x m)

MAXIMUM SPACING

ft (m)

MINIMUM FLOW & RESIDUAL PRESSURE For Horizontal Ceiling (Max. 2” rise for 12” run)

155°F/68°C or 175°F/79°C

12 x 12 (3,7 x 3,7)

12 (3,7)

13 GPM (49,2 LPM) 7.0 psi (0,48 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

13 GPM (49,2 LPM) 7.0 psi (0,48 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

13 GPM (49,2 LPM)7.0 psi (0,48 bar)

18 x 18 (5,5 x 5,5)

18 (5,5)

17 GPM (64,3 LPM) 12.0 psi (0,83 bar)

20 x 20 (6,1 x 6,1)

20 (6,1)

20 GPM (75,7 LPM) 16.7 psi (1,15 bar)

MAXIMUM COVERAGE AREA

ft x ft (m x m)

MAXIMUM SPACING

ft (m)

MINIMUM FLOW & RESIDUAL PRESSURE For Horizontal Ceiling (Max. 2” rise for 12” run)

155°F/68°C or 175°F/79°C

12 x 12 (3,7 x 3,7)

12 (3,7)

8 GPM (30,3 LPM) 7.1 psi (0,49 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

11 GPM (41,6 LPM) 13.4 psi (0,92 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

13 GPM (49,2 LPM)18.8 psi (1,29 bar)

MAXIMUM COVERAGE AREA

MAXIMUM SPACING MINIMUM FLOW & RESIDUAL PRESSURE

ft x ft (m x m) ft (m) 4” – 6” (100 mm – 150 mm) below ceiling 6” – 12” (150 mm – 300 mm) below ceiling

155°F/68°C 175°F/79°C 155°F/68°C 175°F/79°C

12 x 12 (3,7 x 3,7)

12 (3,7)

12 GPM (45,4 LPM) 8.2 psi (0,57 bar)

12 GPM (45,4 LPM) 8.2 psi (0,57 bar)

13 GPM (49,2 LPM) 9.6 psi (0,48 bar)

13 GPM (49,2 LPM) 9.6 psi (0,48 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

14 GPM (53,0 LPM) 11.1 psi (0,77 bar)

16 GPM (60,6 LPM)14.5 psi (1,00 bar)

17 GPM (64, 3 LPM) 16.4 psi (1,13 bar)

18 GPM (68,1 LPM) 18.4 psi (1,27 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

16 GPM (60,6 LPM)14.5 psi (1,00 bar)

16 GPM (60,6 LPM)14.5 psi (1,00 bar)

18 GPM (68,1 LPM) 18.4 psi (1,27 bar)

18 GPM (68,1 LPM) 18.4 psi (1,27 bar)

16 x 18 (4,9 x 5,5)

16 (4,9)

19 GPM (71,9 LPM) 20.5 psi (1,41 bar)

19 GPM (71,9 LPM) 20.5 psi (1,41 bar)

21 GPM (79,5 LPM) 25.0 psi (1,72 bar)

21 GPM (79,5 LPM) 25.0 psi (1,72 bar)

16 x 20 (4,9 x 6,1)

16 (4,9)

23 GPM (87,1 LPM) 30.0 psi (2,07 bar)

19 GPM (71,9 LPM) 20.5 psi (1,41 bar)

26 GPM (98,4 LPM) 38.3 psi (2,64 bar)

26 GPM (98,4 LPM) 38.3 psi (2,64 bar)

MAXIMUM COVERAGE AREA

MAXIMUM SPACING MINIMUM FLOW & RESIDUAL PRESSURE

ft x ft (m x m) ft (m) 4” – 6” (100 mm – 150 mm) below ceiling 6” – 12” (150 mm – 300 mm) top of deflector to ceiling

155°F/68°C 175°F/79°C 155°F/68°C 175°F/79°C

12 x 12 (3,7 x 3,7)

12 (3,7)

13 GPM (49,2 LPM) 8.7 psi (0,60 bar)

13 GPM (49,2 LPM) 8.7 psi (0,60 bar)

13 GPM (49,2 LPM) 8.7 psi (0,60 bar)

13 GPM (49,2 LPM) 8.7 psi (0,60 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

14 GPM (53,0 LPM) 10.1 psi (0,70 bar)

14 GPM (53,0 LPM) 10.1 psi (0,70 bar)

14 GPM (53,0 LPM) 10.1 psi (0,70 bar)

14 GPM (53,0 LPM) 10.1 psi (0,70 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

16 GPM (60,6 LPM)13.2 psi (0,91 bar)

16 GPM (60,6 LPM)13.2 psi (0,91 bar)

17 GPM (64,3 LPM) 14.9 psi (1,03 bar)

17 GPM (64,3 LPM) 14.9 psi (1,03 bar)

16 x 18 (4,9 x 5,5)

16 (4,9)

19 GPM (71,9 LPM) 18.6 psi (1,28 bar)

19 GPM (71,9 LPM) 18.6 psi (1,28 bar)

20 GPM (75.7 LPM) 20.7 psi (1,43 bar)

20 GPM (75.7 LPM) 20.7 psi (1,43 bar)

16 x 20 (4,9 x 6,1)

16 (4,9)

23 GPM (87,1 LPM) 27.3 psi (1,88 bar)

23 GPM (87,1 LPM) 27.3 psi (1,88 bar)

23 GPM (87,1 LPM) 27.3 psi (1,88 bar)

23 GPM (87,1 LPM) 27.3 psi (1,88 bar)

18 x 18 (5,5 x 5,5)

18 (5,5)

23 GPM (87,1 LPM) 27.3 psi (1,88 bar)

23 GPM (87,1 LPM) 27.3 psi (1,88 bar)

23 GPM (87,1 LPM) 27.3 psi (1,88 bar)

23 GPM (87,1 LPM) 27.3 psi (1,88 bar)

18 x 20 (5,5 x 6,1)

18 (5,5)

26 GPM (98,4 LPM) 34.9 psi (2,41 bar)

26 GPM (98,4 LPM) 34.9 psi (2,41 bar)

26 GPM (98,4 LPM) 34.9 psi (2,41 bar)

26 GPM (98,4 LPM) 34.9 psi (2,41 bar)

• Fast response

• Used in wet pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D

• Used in wet pipe residential occupancies up to and including four stories in height per NFPA 13R

• Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

• Fast response

• Used in wet pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D

• Used in wet pipe residential occupancies up to and including four stories in height per NFPA 13R

• Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

K Factor K=4.2 (60,5)

Thread Size 1/2” (15 mm)

Escutcheon Style 20

Bulb Type 3 mm

Finish White, Chrome, Brass

Tech Data TFP410

K Factor K=4.4 (63,4)

Thread Size 1/2” (15 mm)

Escutcheon Style 20

Bulb Type 3 mm

Finish White, Chrome, Brass

Tech Data TFP412

LFII (TY2234) Pendent, Recessed Pendent and Domed Concealed

LFII (TY1234) Pendent and Recessed Pendent LFII (TY2334) Horizontal and Recessed Horizontal Sidewall

LFII (TY1334) Horizontal and Recessed Horizontal Sidewall

Always refer to the technical data sheet for complete description and all listing criteria, design parameters, installation instructions, care and maintenance guidelines and our limited warranty.

Series LFII Sprinklers

• Fast response

• Approved for special applications with beamed ceilings

• Used in wet pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D

• Used in wet pipe residential occupancies up to and including four stories in height per NFPA 13R

• Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

K Factor K=4.9 (70,6)

Thread Size 1/2” (15 mm)

Escutcheon Style 20

Bulb Type 3 mm

Finish White, Chrome, Brass, Custom

Tech Data TFP400 (TFP450 Domed Concealed)

We can match any Sherwin Williams color for Flat Plate and Domed Concealed sprinklers you install. See the cover plate chart on page 7 for standard colors and finishes.

Page 6: Tyco Fire Rapid Response Product Guide_5 2015

K Factor K= 4.9 (70,6)

Thread Size 1/2” (15 mm)

Finish White, Chrome, Brass, Custom

Tech Data TFP442

• Fast response

• Solder type

• Can be used for horizontal and sloped ceilings

• Used in wet pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D

• Used in wet pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R

• Cover plate conceals sprinkler components above ceiling

• Specially designed for installing and removing TYCO LFII and RFII Flat plate concealed cover plates

• Contains foam insert to prevent scratching of cover plate finish

• Attaches to painter’s pole, or a length of 1” CPVC pipe

• No need for ladder or scaffold to install cover plates

MAXIMUM COVERAGE AREA

ft x ft (m x m)

MAXIMUM SPACING

ft (m)

MINIMUM FLOW & RESIDUAL PRESSURE For Horizontal Ceiling (Max. 2” rise for 12” run)

160°F/71°C

12 x 12 (3,7 x 3,7)

12 (3,7)

13 GPM (49,2 LPM) 7.0 psi (0,48 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

13 GPM (49,2 LPM) 7.0 psi (0,48 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

13 GPM (49,2 LPM)7.0 psi (0,48 bar)

18 x 18 (5,5 x 5,5)

18 (5,5)

17 GPM (64,3 LPM) 12.0 psi (0,83 bar)

20 x 20 (6,1 x 6,1)

20 (6,1)

20 GPM (75,7 LPM) 16.7 psi (1,15 bar)

Before Making A Final Color SelectionThe purpose of this color chart is to provide a basic representation of Rapid Response Flat Plate Concealed Cover Plate finish colors. This color chart shall not be used for final color selection, as color differences may occur in print and on monitors when compared to the actual product. Actual color selection should be made from a sample supplied by Tyco Fire Protection Products. Samples shall be prepared using same color applications, tools and techniques to assure consistency and accuracy. Please contact your Tyco Fire Protection Products representative for more information.

Custom Colors Available

Beige (RAL 1001)

Brushed Brass

Light Ivory (RAL 1015)

Brushed Chrome

Jet Black (RAL 9005)

Grey White (RAL 9002)

Terra Brown (RAL 8028)

Signal White (RAL 9003)

Always refer to the technical data sheet for complete description and all listing criteria, design parameters, installation instructions, care and maintenance guidelines and our limited warranty.

LFII (TY3596) Flat Plate Concealed Pendent Flat Plate Concealed Cover Plate Colors & Finishes

Series LFII Sprinklers

Flat Plate Concealed Cover Plate Tool

Page 7: Tyco Fire Rapid Response Product Guide_5 2015

K Factor K= 4.9 (70,6)

Thread Size 1/2” (15 mm)

Finish White, Chrome, Brass, Custom

Tech Data TFP442

• Fast response

• Solder type

• Can be used for horizontal and sloped ceilings

• Used in wet pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D

• Used in wet pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R

• Cover plate conceals sprinkler components above ceiling

• Specially designed for installing and removing TYCO LFII and RFII Flat plate concealed cover plates

• Contains foam insert to prevent scratching of cover plate finish

• Attaches to painter’s pole, or a length of 1” CPVC pipe

• No need for ladder or scaffold to install cover plates

MAXIMUM COVERAGE AREA

ft x ft (m x m)

MAXIMUM SPACING

ft (m)

MINIMUM FLOW & RESIDUAL PRESSURE For Horizontal Ceiling (Max. 2” rise for 12” run)

160°F/71°C

12 x 12 (3,7 x 3,7)

12 (3,7)

13 GPM (49,2 LPM) 7.0 psi (0,48 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

13 GPM (49,2 LPM) 7.0 psi (0,48 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

13 GPM (49,2 LPM)7.0 psi (0,48 bar)

18 x 18 (5,5 x 5,5)

18 (5,5)

17 GPM (64,3 LPM) 12.0 psi (0,83 bar)

20 x 20 (6,1 x 6,1)

20 (6,1)

20 GPM (75,7 LPM) 16.7 psi (1,15 bar)

Before Making A Final Color SelectionThe purpose of this color chart is to provide a basic representation of Rapid Response Flat Plate Concealed Cover Plate finish colors. This color chart shall not be used for final color selection, as color differences may occur in print and on monitors when compared to the actual product. Actual color selection should be made from a sample supplied by Tyco Fire Protection Products. Samples shall be prepared using same color applications, tools and techniques to assure consistency and accuracy. Please contact your Tyco Fire Protection Products representative for more information.

Custom Colors Available

Beige (RAL 1001)

Brushed Brass

Light Ivory (RAL 1015)

Brushed Chrome

Jet Black (RAL 9005)

Grey White (RAL 9002)

Terra Brown (RAL 8028)

Signal White (RAL 9003)

Always refer to the technical data sheet for complete description and all listing criteria, design parameters, installation instructions, care and maintenance guidelines and our limited warranty.

LFII (TY3596) Flat Plate Concealed Pendent Flat Plate Concealed Cover Plate Colors & Finishes

Series LFII Sprinklers

Flat Plate Concealed Cover Plate Tool

Page 8: Tyco Fire Rapid Response Product Guide_5 2015

Always refer to the technical data sheet for complete description and all listing criteria, design parameters, installation instructions, care and maintenance guidelines and our limited warranty.

Series LFII Sprinklers Series LFII Dry Sprinklers

K Factor K= 4.2 (60,5)

Thread Size 1/2” (15 mm)

Finish White, Chrome, Brass, Custom

Tech Data TFP425

MAXIMUM COVERAGE AREA

ft x ft (m x m)

MAXIMUM SPACING

ft (m)

MINIMUM FLOW & RESIDUAL PRESSURE For Horizontal Ceiling (Max. 2” rise for 12” run)

162°F/72°C

12 x 12 (3,7 x 3,7)

12 (3,7)

13 GPM (49,2 LPM) 9.6 psi (0,66 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

13 GPM (49,2 LPM) 9.6 psi (0,66 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

14 GPM (53,0 LPM) 11.1 psi (0,77 bar)

18 x 18 (5,5 x 5,5)

18 (5,5)

18 GPM (68,1 LPM) 18.4 psi (1,27 bar)

20 x 20 (6,1 x 6,1)

20 (6,1)

22 GPM (83.3 LPM) 27.4 psi (1,89 bar)

MAXIMUM COVERAGE AREA

ft x ft (m x m)

MAXIMUM SPACING

ft (m)

MINIMUM FLOW & RESIDUAL PRESSURE Top of Deflector to Ceiling 4” to 6” (100 mm – 150 mm)

162°F/72°C

12 x 12 (3,7 x 3,7)

12 (3,7)

13 GPM (49,2 LPM) 9.6 psi (0,66 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

16 GPM (60,6 LPM) 14.5 psi (1,00 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

20 GPM (75,7 LPM) 22.7 psi (1,57 bar)

• Fast response

• Solder type

• Approved for special applications with beamed ceilings

• Used in wet pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D

• Used in wet pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R

• Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

• Fast response

• Solder type

• Approved for special applications with beamed ceilings

• Used in wet pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D

• Used in wet pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R

• Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

K Factor K=4.2 (60,5)

Thread Size 1/2” (15 mm)

Finish White, Chrome, Brass, Black

Tech Data TFP420

LFII (TY2284) Flush Pendent LFII (TY2235)  Residential Dry Sprinkler, Recessed Pendent

LFII (TY2335) Residential Dry Sprinkler, Horizontal SidewallLFII (TY2284) Flush Horizontal Sidewall

MAXIMUM COVERAGE AREA

MAXIMUM SPACING

MINIMUM FLOW & RESIDUAL PRESSURE For Horizontal Ceilings (Max. 2” rise for 12” run)

ft x ft (m x m) ft (m) 4” – 6” (100 mm – 150 mm) Top of Deflector to Ceiling 6” – 12” (150 mm – 300 mm) Top of Deflector to Ceiling

DRY PIPE WET PIPE DRY PIPE WET PIPE

12 x 12 (3,7 x 3,7)

12 (3,7)

13 GPM (49,2 LPM) 8.7 psi (0,60 bar)

13 GPM (49,2 LPM) 8.7 psi (0,60 bar)

15 GPM (56,8 LPM) 11.6 psi (0,80 bar)

15 GPM (56,8 LPM) 11.6 psi (0,80 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

16 GPM (60,6 LPM) 13.2 psi (0,91 bar)

14 GPM (53,0 LPM) 10.1 psi (0,70 bar)

16 GPM (60,6 LPM) 13.2 psi (0,91 bar)

15 GPM (56,8 LPM) 11.6 psi (0,80 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

17 GPM (64,3 LPM)14.9 psi (1,03 bar)

17 GPM (64,3 LPM)14.9 psi (1,03 bar)

19 GPM (71,9 LPM) 18.6 psi (1,28 bar)

19 GPM (71,9 LPM) 18.6 psi (1,28 bar)

16 x 18 (4,9 x 5,5)

16 (4,9) N/A 19 GPM (71,9 LPM)

18.6 psi (1,28 bar) N/A 20 GPM (75,7 LPM) 20.7 psi (1,43 bar)

16 x 20 (4,9 x 6,1)

16 (4,9) N/A 25 GPM (94,6 LPM)

32.3 psi (2,23 bar) N/A 25 GPM (94,6 LPM) 32.3 psi (2,23 bar)

MAXIMUM COVERAGE AREA

MAXIMUM SPACING

MINIMUM FLOW & RESIDUAL PRESSURE For Horizontal Ceilings (Max. 2” rise for 12” run)

ft x ft (m x m) ft (m)

DRY PIPE WET PIPE

12 x 12 (3,7 x 3,7)

12 (3,7)

13 GPM (49,2 LPM) 7.0 psi (0,48 bar)

13 GPM (49,2 LPM) 7.0 psi (0,48 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

14 GPM (52,9 LPM) 8.2 psi (0,57 bar)

14 GPM (52,9 LPM) 8.2 psi (0,57 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

15 GPM (56,8 LPM) 9.4 psi (0,65 bar)

15 GPM (56,8 LPM) 9.4 psi (0,65 bar)

16 x 18 (4,9 x 5,5)

16 (4,9)

18 GPM (68,1 LPM) 13.5 psi (0,93 bar)

18 GPM (68,1 LPM) 13.5 psi (0,93 bar)

16 x 20 (4,9 x 6,1)

16 (4,9)

21 GPM (79,5 LPM) 18.3 psi (1,30 bar)

21 GPM (79,5 LPM) 18.4 psi (1,30 bar)

K Factor K=4.9 (70,6)

Thread Size 1” NPT (25 mm)

Bulb Type 3 mm

Finish White, Chrome, Brass

Tech Data TFP460

K Factor K=4.4 (63,4)

Thread Size 1” NPT (25 mm)

Bulb Type 3 mm

Finish White, Chrome, Brass

Tech Data TFP461

• Fast response

• For residential occupancies per NFPA 13D, 13R and residential portions of any occupancy per NFPA 13

• UL listed for use in wet pipe, dry pipe and pre action systems

• Fast response

• For residential occupancies per NFPA 13D, 13R and residential portions of any occupancy per NFPA 13

• UL listed for use in wet pipe, dry pipe and pre action systems

Page 9: Tyco Fire Rapid Response Product Guide_5 2015

Always refer to the technical data sheet for complete description and all listing criteria, design parameters, installation instructions, care and maintenance guidelines and our limited warranty.

Series LFII Sprinklers Series LFII Dry Sprinklers

K Factor K= 4.2 (60,5)

Thread Size 1/2” (15 mm)

Finish White, Chrome, Brass, Custom

Tech Data TFP425

MAXIMUM COVERAGE AREA

ft x ft (m x m)

MAXIMUM SPACING

ft (m)

MINIMUM FLOW & RESIDUAL PRESSURE For Horizontal Ceiling (Max. 2” rise for 12” run)

162°F/72°C

12 x 12 (3,7 x 3,7)

12 (3,7)

13 GPM (49,2 LPM) 9.6 psi (0,66 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

13 GPM (49,2 LPM) 9.6 psi (0,66 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

14 GPM (53,0 LPM) 11.1 psi (0,77 bar)

18 x 18 (5,5 x 5,5)

18 (5,5)

18 GPM (68,1 LPM) 18.4 psi (1,27 bar)

20 x 20 (6,1 x 6,1)

20 (6,1)

22 GPM (83.3 LPM) 27.4 psi (1,89 bar)

MAXIMUM COVERAGE AREA

ft x ft (m x m)

MAXIMUM SPACING

ft (m)

MINIMUM FLOW & RESIDUAL PRESSURE Top of Deflector to Ceiling 4” to 6” (100 mm – 150 mm)

162°F/72°C

12 x 12 (3,7 x 3,7)

12 (3,7)

13 GPM (49,2 LPM) 9.6 psi (0,66 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

16 GPM (60,6 LPM) 14.5 psi (1,00 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

20 GPM (75,7 LPM) 22.7 psi (1,57 bar)

• Fast response

• Solder type

• Approved for special applications with beamed ceilings

• Used in wet pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D

• Used in wet pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R

• Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

• Fast response

• Solder type

• Approved for special applications with beamed ceilings

• Used in wet pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D

• Used in wet pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R

• Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

K Factor K=4.2 (60,5)

Thread Size 1/2” (15 mm)

Finish White, Chrome, Brass, Black

Tech Data TFP420

LFII (TY2284) Flush Pendent LFII (TY2235)  Residential Dry Sprinkler, Recessed Pendent

LFII (TY2335) Residential Dry Sprinkler, Horizontal SidewallLFII (TY2284) Flush Horizontal Sidewall

MAXIMUM COVERAGE AREA

MAXIMUM SPACING

MINIMUM FLOW & RESIDUAL PRESSURE For Horizontal Ceilings (Max. 2” rise for 12” run)

ft x ft (m x m) ft (m) 4” – 6” (100 mm – 150 mm) Top of Deflector to Ceiling 6” – 12” (150 mm – 300 mm) Top of Deflector to Ceiling

DRY PIPE WET PIPE DRY PIPE WET PIPE

12 x 12 (3,7 x 3,7)

12 (3,7)

13 GPM (49,2 LPM) 8.7 psi (0,60 bar)

13 GPM (49,2 LPM) 8.7 psi (0,60 bar)

15 GPM (56,8 LPM) 11.6 psi (0,80 bar)

15 GPM (56,8 LPM) 11.6 psi (0,80 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

16 GPM (60,6 LPM) 13.2 psi (0,91 bar)

14 GPM (53,0 LPM) 10.1 psi (0,70 bar)

16 GPM (60,6 LPM) 13.2 psi (0,91 bar)

15 GPM (56,8 LPM) 11.6 psi (0,80 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

17 GPM (64,3 LPM)14.9 psi (1,03 bar)

17 GPM (64,3 LPM)14.9 psi (1,03 bar)

19 GPM (71,9 LPM) 18.6 psi (1,28 bar)

19 GPM (71,9 LPM) 18.6 psi (1,28 bar)

16 x 18 (4,9 x 5,5)

16 (4,9) N/A 19 GPM (71,9 LPM)

18.6 psi (1,28 bar) N/A 20 GPM (75,7 LPM) 20.7 psi (1,43 bar)

16 x 20 (4,9 x 6,1)

16 (4,9) N/A 25 GPM (94,6 LPM)

32.3 psi (2,23 bar) N/A 25 GPM (94,6 LPM) 32.3 psi (2,23 bar)

MAXIMUM COVERAGE AREA

MAXIMUM SPACING

MINIMUM FLOW & RESIDUAL PRESSURE For Horizontal Ceilings (Max. 2” rise for 12” run)

ft x ft (m x m) ft (m)

DRY PIPE WET PIPE

12 x 12 (3,7 x 3,7)

12 (3,7)

13 GPM (49,2 LPM) 7.0 psi (0,48 bar)

13 GPM (49,2 LPM) 7.0 psi (0,48 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

14 GPM (52,9 LPM) 8.2 psi (0,57 bar)

14 GPM (52,9 LPM) 8.2 psi (0,57 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

15 GPM (56,8 LPM) 9.4 psi (0,65 bar)

15 GPM (56,8 LPM) 9.4 psi (0,65 bar)

16 x 18 (4,9 x 5,5)

16 (4,9)

18 GPM (68,1 LPM) 13.5 psi (0,93 bar)

18 GPM (68,1 LPM) 13.5 psi (0,93 bar)

16 x 20 (4,9 x 6,1)

16 (4,9)

21 GPM (79,5 LPM) 18.3 psi (1,30 bar)

21 GPM (79,5 LPM) 18.4 psi (1,30 bar)

K Factor K=4.9 (70,6)

Thread Size 1” NPT (25 mm)

Bulb Type 3 mm

Finish White, Chrome, Brass

Tech Data TFP460

K Factor K=4.4 (63,4)

Thread Size 1” NPT (25 mm)

Bulb Type 3 mm

Finish White, Chrome, Brass

Tech Data TFP461

• Fast response

• For residential occupancies per NFPA 13D, 13R and residential portions of any occupancy per NFPA 13

• UL listed for use in wet pipe, dry pipe and pre action systems

• Fast response

• For residential occupancies per NFPA 13D, 13R and residential portions of any occupancy per NFPA 13

• UL listed for use in wet pipe, dry pipe and pre action systems

Page 10: Tyco Fire Rapid Response Product Guide_5 2015

NFPA 13 Optimized SprinklersThe large orifice 6.9 K, 5.6 K and 5.8 K sprinklers are primarily intended for residential use where there is a 0.1 gpm/sq. ft. density NFPA 13 design requirement, and are generally used for installations in excess  of four stories. They are optimized for residential applications where this higher water-flow demand is  required, and can meet those requirements with less pressure and smaller pipe sizes.

Always refer to the technical data sheet for complete description and all listing criteria, design parameters, installation instructions, care and maintenance guidelines and our limited warranty.

LFII (TY4234)  Pendent, Recessed Pendent and Domed Concealed LFII (TY3934)  5.8K Pendent, Recessed Pendent

• Fast response

• Used in wet pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D

• Used in wet pipe residential occupancies up to and including four stories in height per NFPA 13R

• Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

K Factor K=6.9 (99,4)

Thread Size 3/4” (19.05 mm)

Escutcheon Style 30

Bulb Type 3 mm

Finish White, Chrome, Brass, Custom

Tech Data TFP408

MAXIMUM COVERAGE AREA

MAXIMUM SPACING

MINIMUM FLOW & RESIDUAL PRESSURE For Horizontal Ceilings (Max. 2” rise for 12” run)

ft x ft (m x m) ft (m) Pendent and Recessed Pendent Concealed Pendent

155°F/68°C or 175°F/79°C 155°F/68°C or 175°F/79°C

12 x 12 (3,7 x 3,7)

12 (3,7)

19 GPM (71,9 LPM) 7.6 psi (0,52 bar)

19 GPM (71,9 LPM) 7.6 psi (0,52 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

19 GPM (71,9 LPM) 7.6 psi (0,52 bar)

19 GPM (71,9 LPM) 7.6 psi (0,52 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

19 GPM (71,9 LPM) 7.6 psi (0,52 bar)

19 GPM (71,9 LPM) 7.6 psi (0,52 bar)

18 x 18 (5,5 x 5,5)

18 (5,5)

19 GPM (71,9 LPM) 7.6 psi (0,52 bar)

21 GPM (79,5 LPM) 9.3 psi (0,64 bar)

20 x 20 (6,1 x 6,1)

20 (6,1)

22 GPM (87,1 LPM) 10.2 psi (2,07 bar)

24 GPM (90,8 LPM) 12.1 psi (1,15 bar)

K Factor K=5.8 (83,5)

Thread Size 1/2” (19.05 mm)

Escutcheon Style 20

Bulb Type 3 mm

Finish Natural Brass, Pure or Signal White, Jet Black, Chrome Plated

Tech Data TFP401

MAXIMUM COVERAGE AREA

MINIMUM SPACING

MINIMUM FLOW & RESIDUAL PRESSURE Pendent and Recessed Pendent

ft x ft (m x m) ft (m) 155°F/68°C / 175°F (79°C)

12 x 12 (3,7 x 3,7)

12 (3,7)

16 GPM (60,6 LPM) 7.6 psi (0,52 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

16 GPM (60,6 LPM) 7.6 psi (0,52 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

16 GPM (60,6 LPM) 7.6 psi (0,52 bar)

18 x 18 (5,5 x 5,5)

18 (5,5)

18 GPM (68,1 LPM) 9.6 psi (0,66 bar)

20 x 20 (6,1 x 6,1)

20 (6,1)

20 GPM (75,7 LPM) 11.9 psi (0,82 bar)

• UL and C-UL Listed

• Fast response

• Used in wet pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D

• Used in wet pipe residential occupancies up to and including four stories in height per NFPA 13R

• Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

Page 11: Tyco Fire Rapid Response Product Guide_5 2015

NFPA 13 Optimized SprinklersThe large orifice 6.9 K, 5.6 K and 5.8 K sprinklers are primarily intended for residential use where there is a 0.1 gpm/sq. ft. density NFPA 13 design requirement, and are generally used for installations in excess  of four stories. They are optimized for residential applications where this higher water-flow demand is  required, and can meet those requirements with less pressure and smaller pipe sizes.

Always refer to the technical data sheet for complete description and all listing criteria, design parameters, installation instructions, care and maintenance guidelines and our limited warranty.

LFII (TY4234)  Pendent, Recessed Pendent and Domed Concealed LFII (TY3934)  5.8K Pendent, Recessed Pendent

• Fast response

• Used in wet pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D

• Used in wet pipe residential occupancies up to and including four stories in height per NFPA 13R

• Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

K Factor K=6.9 (99,4)

Thread Size 3/4” (19.05 mm)

Escutcheon Style 30

Bulb Type 3 mm

Finish White, Chrome, Brass, Custom

Tech Data TFP408

MAXIMUM COVERAGE AREA

MAXIMUM SPACING

MINIMUM FLOW & RESIDUAL PRESSURE For Horizontal Ceilings (Max. 2” rise for 12” run)

ft x ft (m x m) ft (m) Pendent and Recessed Pendent Concealed Pendent

155°F/68°C or 175°F/79°C 155°F/68°C or 175°F/79°C

12 x 12 (3,7 x 3,7)

12 (3,7)

19 GPM (71,9 LPM) 7.6 psi (0,52 bar)

19 GPM (71,9 LPM) 7.6 psi (0,52 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

19 GPM (71,9 LPM) 7.6 psi (0,52 bar)

19 GPM (71,9 LPM) 7.6 psi (0,52 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

19 GPM (71,9 LPM) 7.6 psi (0,52 bar)

19 GPM (71,9 LPM) 7.6 psi (0,52 bar)

18 x 18 (5,5 x 5,5)

18 (5,5)

19 GPM (71,9 LPM) 7.6 psi (0,52 bar)

21 GPM (79,5 LPM) 9.3 psi (0,64 bar)

20 x 20 (6,1 x 6,1)

20 (6,1)

22 GPM (87,1 LPM) 10.2 psi (2,07 bar)

24 GPM (90,8 LPM) 12.1 psi (1,15 bar)

K Factor K=5.8 (83,5)

Thread Size 1/2” (19.05 mm)

Escutcheon Style 20

Bulb Type 3 mm

Finish Natural Brass, Pure or Signal White, Jet Black, Chrome Plated

Tech Data TFP401

MAXIMUM COVERAGE AREA

MINIMUM SPACING

MINIMUM FLOW & RESIDUAL PRESSURE Pendent and Recessed Pendent

ft x ft (m x m) ft (m) 155°F/68°C / 175°F (79°C)

12 x 12 (3,7 x 3,7)

12 (3,7)

16 GPM (60,6 LPM) 7.6 psi (0,52 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

16 GPM (60,6 LPM) 7.6 psi (0,52 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

16 GPM (60,6 LPM) 7.6 psi (0,52 bar)

18 x 18 (5,5 x 5,5)

18 (5,5)

18 GPM (68,1 LPM) 9.6 psi (0,66 bar)

20 x 20 (6,1 x 6,1)

20 (6,1)

20 GPM (75,7 LPM) 11.9 psi (0,82 bar)

• UL and C-UL Listed

• Fast response

• Used in wet pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D

• Used in wet pipe residential occupancies up to and including four stories in height per NFPA 13R

• Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

Page 12: Tyco Fire Rapid Response Product Guide_5 2015

NFPA 13 Optimized SprinklersThe large orifice 6.9 K, 5.6 K and 5.8 K sprinklers are primarily intended for residential use where there is a 0.1 gpm/sq. ft. density NFPA 13 design requirement, and are generally used for installations in excess  of four stories. They are optimized for residential applications where this higher water-flow demand is  required, and can meet those requirements with less pressure and smaller pipe sizes.

Always refer to the technical data sheet for complete description and all listing criteria, design parameters, installation instructions, care and maintenance guidelines and our limited warranty.

MAXIMUM COVERAGE AREA

MAXIMUM SPACING MINIMUM FLOW & RESIDUAL PRESSURE

ft x ft (m x m) ft (m) 4” – 6” (100 mm – 150 mm) Top of Deflector to Ceiling 6” – 12” (152 mm – 305 mm) Top of Deflector to Ceiling

155°F/68°C 175°F/79°C 155°F/68°C 175°F/79°C

Recessed of Non-Recessed

12 x 12 (3,7 x 3,7)

12 (3,7)

19 GPM (71,9 LPM) 10.7 psi (0,74 bar)

19 GPM (71,9 LPM) 10.7 psi (0,74 bar)

19 GPM (71,9 LPM) 10.7 psi (0,74 bar)

19 GPM (71,9 LPM) 10.7 psi (0,74 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

21 GPM (79,5 LPM) 13.1 psi (0,90 bar)

21 GPM (79,5 LPM) 13.1 psi (0,90 bar)

23 GPM (79,5 LPM) 15.7 psi (1,08 bar)

23 GPM (79,5 LPM) 15.7 psi (1,08 bar)

16 x 14 (4,9 x 4,9)

16 (4,9)

21 GPM (79,5 LPM) 13.1 psi (0,90 bar)

21 GPM (79,5 LPM) 13.1 psi (0,90 bar)

23 GPM (79,5 LPM) 15.7 psi (1,08 bar)

23 GPM (79,5 LPM) 15.7 psi (1,08 bar)

16 x 16 (4,9 x 4,9 )

16 (4,9)

21 GPM (79,5 LPM) 13.1 psi (0,90 bar)

21 GPM (79,5 LPM) 13.1 psi (0,90 bar)

23 GPM (79,5 LPM) 15.7 psi (1,08 bar)

23 GPM (79,5 LPM) 15.7 psi (1,08 bar)

16 x 18 (4,9 x 5,5)

16 (4,9)

23 GPM (79,5 LPM) 15.7 psi (1,08 bar)

23 GPM (79,5 LPM) 15.7 psi (1,08 bar)

24 GPM (90,8 LPM) 17.1 psi (1,18 bar)

24 GPM (90,8 LPM) 17.1 psi (1,18 bar)

16 x 20 (4,9 x 6,7)

16 (4,9)

29 GPM (109,8 LPM) 25.0 psi (1,72 bar)

29 GPM (109,8 LPM) 25.0 psi (1,72 bar)

30 GPM (113,6 LPM) 26.8 psi (1,85 bar)

30 GPM (113,6 LPM) 26.8 psi (1,85 bar)

18 x 18 (5,5 x 5,5)

18 (5,5)

29 GPM (109,8 LPM) 25.0 psi (1,72 bar)

29 GPM (109,8 LPM) 25.0 psi (1,72 bar)

30 GPM (113,6 LPM) 26.8 psi (1,85 bar)

30 GPM (113,6 LPM) 26.8 psi (1,85 bar)

Non-Recessed

16 x 22 (4,9 x 6,7)

16 (4,9)

38 GPM (143,8 LPM) 42.9 psi (2,96 bar)

38 GPM (143,8 LPM) 42.9 psi (2,96 bar)

40 GPM (151,4 LPM) 47.6 psi (2,96 bar)

40 GPM (151,4 LPM) 47.6 psi (2,96 bar)

K Factor K=5.8 (80,6)

Thread Size 1/2” (15 mm)

Bulb Type 3 mm

Finish White, Chrome, Brass

Tech Data TFP417

LFII (TY4334) Horizontal and Recessed Horizontal Sidewall

• Fast response

• Used in wet pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D

• Used in wet pipe residential occupancies up to and including four stories in height per NFPA 13R

• Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

LFII (TY3334) Horizontal and Recessed Horizontal Sidewall

• Fast response

• Used in wet pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D

• Used in wet pipe residential occupancies up to and including four stories in height per NFPA 13R

• Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

K Factor K=5.6 (80,6)

Thread Size 1/2” (15 mm)

Escutcheon Style 20

Bulb Type 3 mm

Finish White, Chrome, Brass, Custom

Tech Data TFP415

MAXIMUM COVERAGE AREA

MAXIMUM SPACING

MINIMUM FLOW & RESIDUAL PRESSURE For Horizontal Ceilings (Max. 2” rise for 12” run)

ft x ft (m x m) ft (m) 4” to 6” (102 mm—152 mm) 6” to 12” (152 mm—305 mm)

155°F/68°C or 175°F/79°C 155°F/68°C or 175°F/79°C

12 x 12 (3,7 x 3,7)

12 (3,7)

17 GPM (64,3 LPM) 9.2 psi (0,63 bar)

20 GPM (75,7 LPM) 12.8 psi (0,88 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

19 GPM (71,9 LPM) 11.5 psi (0,79 bar)

22 GPM (83,3 LPM) 15.4 psi (1,06 bar)

16 x 14 (4,9 x 4,3)

16 (4,9)

20 GPM (75,7 LPM) 12.8 psi (0,88 bar)

24 GPM (90,8 LPM) 18.4 psi (1,27 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

24 GPM (90,8 LPM) 18.4 psi (1,27 bar)

28 GPM (106,0 LPM) 25.0 psi (1,72 bar)

16 x 18 (4,9 x 5,5)

16 (4,9)

26 GPM (98,4 LPM) 21.6 psi (1,49 bar)

31 GPM (117,3 LPM) 30.6 psi (2,11 bar)

16 x 20 (4,9 x 6,1)

16 (4,9)

29 GPM (109,8 LPM) 26.8 psi (1,85 bar)

37 GPM (140,0 LPM) 43.7 psi (3,01 bar)

Page 13: Tyco Fire Rapid Response Product Guide_5 2015

NFPA 13 Optimized SprinklersThe large orifice 6.9 K, 5.6 K and 5.8 K sprinklers are primarily intended for residential use where there is a 0.1 gpm/sq. ft. density NFPA 13 design requirement, and are generally used for installations in excess  of four stories. They are optimized for residential applications where this higher water-flow demand is  required, and can meet those requirements with less pressure and smaller pipe sizes.

Always refer to the technical data sheet for complete description and all listing criteria, design parameters, installation instructions, care and maintenance guidelines and our limited warranty.

MAXIMUM COVERAGE AREA

MAXIMUM SPACING MINIMUM FLOW & RESIDUAL PRESSURE

ft x ft (m x m) ft (m) 4” – 6” (100 mm – 150 mm) Top of Deflector to Ceiling 6” – 12” (152 mm – 305 mm) Top of Deflector to Ceiling

155°F/68°C 175°F/79°C 155°F/68°C 175°F/79°C

Recessed of Non-Recessed

12 x 12 (3,7 x 3,7)

12 (3,7)

19 GPM (71,9 LPM) 10.7 psi (0,74 bar)

19 GPM (71,9 LPM) 10.7 psi (0,74 bar)

19 GPM (71,9 LPM) 10.7 psi (0,74 bar)

19 GPM (71,9 LPM) 10.7 psi (0,74 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

21 GPM (79,5 LPM) 13.1 psi (0,90 bar)

21 GPM (79,5 LPM) 13.1 psi (0,90 bar)

23 GPM (79,5 LPM) 15.7 psi (1,08 bar)

23 GPM (79,5 LPM) 15.7 psi (1,08 bar)

16 x 14 (4,9 x 4,9)

16 (4,9)

21 GPM (79,5 LPM) 13.1 psi (0,90 bar)

21 GPM (79,5 LPM) 13.1 psi (0,90 bar)

23 GPM (79,5 LPM) 15.7 psi (1,08 bar)

23 GPM (79,5 LPM) 15.7 psi (1,08 bar)

16 x 16 (4,9 x 4,9 )

16 (4,9)

21 GPM (79,5 LPM) 13.1 psi (0,90 bar)

21 GPM (79,5 LPM) 13.1 psi (0,90 bar)

23 GPM (79,5 LPM) 15.7 psi (1,08 bar)

23 GPM (79,5 LPM) 15.7 psi (1,08 bar)

16 x 18 (4,9 x 5,5)

16 (4,9)

23 GPM (79,5 LPM) 15.7 psi (1,08 bar)

23 GPM (79,5 LPM) 15.7 psi (1,08 bar)

24 GPM (90,8 LPM) 17.1 psi (1,18 bar)

24 GPM (90,8 LPM) 17.1 psi (1,18 bar)

16 x 20 (4,9 x 6,7)

16 (4,9)

29 GPM (109,8 LPM) 25.0 psi (1,72 bar)

29 GPM (109,8 LPM) 25.0 psi (1,72 bar)

30 GPM (113,6 LPM) 26.8 psi (1,85 bar)

30 GPM (113,6 LPM) 26.8 psi (1,85 bar)

18 x 18 (5,5 x 5,5)

18 (5,5)

29 GPM (109,8 LPM) 25.0 psi (1,72 bar)

29 GPM (109,8 LPM) 25.0 psi (1,72 bar)

30 GPM (113,6 LPM) 26.8 psi (1,85 bar)

30 GPM (113,6 LPM) 26.8 psi (1,85 bar)

Non-Recessed

16 x 22 (4,9 x 6,7)

16 (4,9)

38 GPM (143,8 LPM) 42.9 psi (2,96 bar)

38 GPM (143,8 LPM) 42.9 psi (2,96 bar)

40 GPM (151,4 LPM) 47.6 psi (2,96 bar)

40 GPM (151,4 LPM) 47.6 psi (2,96 bar)

K Factor K=5.8 (80,6)

Thread Size 1/2” (15 mm)

Bulb Type 3 mm

Finish White, Chrome, Brass

Tech Data TFP417

LFII (TY4334) Horizontal and Recessed Horizontal Sidewall

• Fast response

• Used in wet pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D

• Used in wet pipe residential occupancies up to and including four stories in height per NFPA 13R

• Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

LFII (TY3334) Horizontal and Recessed Horizontal Sidewall

• Fast response

• Used in wet pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D

• Used in wet pipe residential occupancies up to and including four stories in height per NFPA 13R

• Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

K Factor K=5.6 (80,6)

Thread Size 1/2” (15 mm)

Escutcheon Style 20

Bulb Type 3 mm

Finish White, Chrome, Brass, Custom

Tech Data TFP415

MAXIMUM COVERAGE AREA

MAXIMUM SPACING

MINIMUM FLOW & RESIDUAL PRESSURE For Horizontal Ceilings (Max. 2” rise for 12” run)

ft x ft (m x m) ft (m) 4” to 6” (102 mm—152 mm) 6” to 12” (152 mm—305 mm)

155°F/68°C or 175°F/79°C 155°F/68°C or 175°F/79°C

12 x 12 (3,7 x 3,7)

12 (3,7)

17 GPM (64,3 LPM) 9.2 psi (0,63 bar)

20 GPM (75,7 LPM) 12.8 psi (0,88 bar)

14 x 14 (4,3 x 4,3)

14 (4,3)

19 GPM (71,9 LPM) 11.5 psi (0,79 bar)

22 GPM (83,3 LPM) 15.4 psi (1,06 bar)

16 x 14 (4,9 x 4,3)

16 (4,9)

20 GPM (75,7 LPM) 12.8 psi (0,88 bar)

24 GPM (90,8 LPM) 18.4 psi (1,27 bar)

16 x 16 (4,9 x 4,9)

16 (4,9)

24 GPM (90,8 LPM) 18.4 psi (1,27 bar)

28 GPM (106,0 LPM) 25.0 psi (1,72 bar)

16 x 18 (4,9 x 5,5)

16 (4,9)

26 GPM (98,4 LPM) 21.6 psi (1,49 bar)

31 GPM (117,3 LPM) 30.6 psi (2,11 bar)

16 x 20 (4,9 x 6,1)

16 (4,9)

29 GPM (109,8 LPM) 26.8 psi (1,85 bar)

37 GPM (140,0 LPM) 43.7 psi (3,01 bar)

Page 14: Tyco Fire Rapid Response Product Guide_5 2015

Residential Domestic  Shut-off Valve 1” and 2”• Used in piping systems that supply water to

both domestic service and the fire sprinkler system designed per NFPA 13D or 13R in one/two- family dwellings and mobile homes

• In the set position, water is available on demand to the domestic system, and the valve acts as a check valve for the fire protection system

• When a sprinkler operates, the supply to the domestic system is automatically shut off, maximizing the available water supply for fire protection

• Eliminates the need for expensive pumps, pressurized tanks, or electrically operated domestic shutoff valves

“Powerball” Butterfly Valves• Ideal for use in residential sprinkler systems

as main control valves

• An alternative to bulky OS&Y valves

• Mandated visual indicator showing that the valve is open or closed

• Available from 1” through 2-1/2”

Resi-Riser• Compact, pre-assembled, ready to install sprinkler riser

• Brass construction for use in potable water supply

• Available in 1” - 2” (25 mm - 50 mm) sizes

• Integral test and drain assembly, flow switch with retard mechanism, 300 psi gauge, and check valve

• Compact size allows for easy installation between 2” x 4” studs in wall

• Molded mounting points allow for fast and easy left or right-hand installation

• Available with or without pressure relief valve feature and flow switch retard mechanism

Riser Manifold• Available in 1” - 2”

• Available in either threaded or grooved configurations

• Meets NFPA 13, 13R and 13D requirements

System Components

Model VS-SP  WaterFlow Detector • Used with wet pipe sprinkler systems in

residential dwellings and mobile homes

• Actuation of the switch can initiate an alarm indicating that the sprinkler system is operating

• Sustained flow of 8 gallons per minute will deflect the vane and actuate a single-pole, double-throw snap action switch

• Can be wired to a local bell and/or protection panel for outside notification to an alarm company or fire department

Hangers for BlazeMaster® CPVC ProductsTyco offers a full line of pipe hangers designed especially for use with BlazeMaster® CPVC Products.

• Designed for ease of installation

• Hangers have rounded edges to prevent damage to pipe and fittings

• Meets the requirements specified in NFPA 13, NFPA 13R and NFPA 13D

Sprinkler Head Cabinet• Spare sprinkler head cabinets are available.

All cabinets have ample room for sprinkler wrench storage.

Electric Alarm Bell• Ideally suited for residential applications

• Unobtrusive to the homeowner, yet absolutely dependable in a fire event

• When used with a flow switch, if water flow occurs in a sprinkler system protecting residential occupancies, an audible alarm sounds to alert the occupants and neighbors of trouble

CPVC Installation Equipment• Retrofit Tools

• Cutting and Deburring Tools

• BlazeMaster Caulk & Walk® Firestop

• One-step CPVC Cement and Daubers

• Hangers & Fasteners

Always refer to the technical data sheet for complete description and all listing criteria, design parameters, installation instructions, care and maintenance guidelines and our limited warranty.

Page 15: Tyco Fire Rapid Response Product Guide_5 2015

Residential Domestic  Shut-off Valve 1” and 2”• Used in piping systems that supply water to

both domestic service and the fire sprinkler system designed per NFPA 13D or 13R in one/two- family dwellings and mobile homes

• In the set position, water is available on demand to the domestic system, and the valve acts as a check valve for the fire protection system

• When a sprinkler operates, the supply to the domestic system is automatically shut off, maximizing the available water supply for fire protection

• Eliminates the need for expensive pumps, pressurized tanks, or electrically operated domestic shutoff valves

“Powerball” Butterfly Valves• Ideal for use in residential sprinkler systems

as main control valves

• An alternative to bulky OS&Y valves

• Mandated visual indicator showing that the valve is open or closed

• Available from 1” through 2-1/2”

Resi-Riser• Compact, pre-assembled, ready to install sprinkler riser

• Brass construction for use in potable water supply

• Available in 1” - 2” (25 mm - 50 mm) sizes

• Integral test and drain assembly, flow switch with retard mechanism, 300 psi gauge, and check valve

• Compact size allows for easy installation between 2” x 4” studs in wall

• Molded mounting points allow for fast and easy left or right-hand installation

• Available with or without pressure relief valve feature and flow switch retard mechanism

Riser Manifold• Available in 1” - 2”

• Available in either threaded or grooved configurations

• Meets NFPA 13, 13R and 13D requirements

System Components

Model VS-SP  WaterFlow Detector • Used with wet pipe sprinkler systems in

residential dwellings and mobile homes

• Actuation of the switch can initiate an alarm indicating that the sprinkler system is operating

• Sustained flow of 8 gallons per minute will deflect the vane and actuate a single-pole, double-throw snap action switch

• Can be wired to a local bell and/or protection panel for outside notification to an alarm company or fire department

Hangers for BlazeMaster® CPVC ProductsTyco offers a full line of pipe hangers designed especially for use with BlazeMaster® CPVC Products.

• Designed for ease of installation

• Hangers have rounded edges to prevent damage to pipe and fittings

• Meets the requirements specified in NFPA 13, NFPA 13R and NFPA 13D

Sprinkler Head Cabinet• Spare sprinkler head cabinets are available.

All cabinets have ample room for sprinkler wrench storage.

Electric Alarm Bell• Ideally suited for residential applications

• Unobtrusive to the homeowner, yet absolutely dependable in a fire event

• When used with a flow switch, if water flow occurs in a sprinkler system protecting residential occupancies, an audible alarm sounds to alert the occupants and neighbors of trouble

CPVC Installation Equipment• Retrofit Tools

• Cutting and Deburring Tools

• BlazeMaster Caulk & Walk® Firestop

• One-step CPVC Cement and Daubers

• Hangers & Fasteners

Always refer to the technical data sheet for complete description and all listing criteria, design parameters, installation instructions, care and maintenance guidelines and our limited warranty.

Page 16: Tyco Fire Rapid Response Product Guide_5 2015

The Rapid Response Residential Fire Sprinkler System features CPVC Pipe and Fittings manufactured with Lubrizol’s BlazeMaster® compound – listed by Underwriters Laboratories, Inc. for use in:

• Light hazard occupancies as defined in the Standard for Installation of Fire Sprinkler Systems, NFPA 13

• Residential occupancies as defined in the Standard for Installation of Fire Sprinkler Systems in Residential Occupancies up to Four Stories in Height, NFPA 13R

• Residential occupancies as defined in the Standard for Fire Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes, NFPA 13D

• Air plenums, as defined by the Installation of Air Conditioning and Ventilating Systems, NFPA 90A and model mechanical codes

• Underground water pressure service, NFPA 24

• Unfinished basements

(Note: for complete listing and approval information, please refer to the installation instructions and technical manual No. 19-1.0.)

CPVC Pipe & FittingsAlways refer to the technical data sheet for complete description and all listing criteria, design parameters, installation instructions, care and maintenance guidelines and our limited warranty.

Install With ConfidenceTyco BlazeMaster® CPVC Piping Systems are UL and cUL listed, FM approved, and exceed ASTM standards. Benefits over traditional piping systems include:

• Resistant to rust, scale and foreign contaminant buildup

• Superior flow characteristics for increased hydraulic capabilities (C-Factor=150)

• Easily transported, handled and modified on site

• Can be easily connected to copper and steel piping

• Resist sweating and condensation

• Immune to Microbiologically Influenced Corrosion (MIC)

Fire Performance• CPVC has an LOI (Limited Oxygen Index) that is

better than wood, PVC, PB or other common building materials. It will not support combustion; therefore, it cannot be the source of a fire or cause a fire to spread.

• Does not contribute to flashover

• Low smoke generation

• Toxicity is extremely low when compared with common building and finishing materials; equal to wood and less than wool or cotton (University of Pittsburgh protocol)

CPVC PIPE (3/4” — 3”)

CPVC CROSS

CPVC ELBOW 90°

CPVC ELBOW 45° CPVC REDUCING TEE

CPVC COUPLING

CPVC REDUCING COUPLING

CPVC BUSHING

CPVC CAP

CPVC TEE

BACK-TO-BACK CROSS SPRINKLER

HEAD ADAPTER

CPVC TO COPPER-FEMALE ADAPTER (SLIP X FEMALE)

CPVC MALE ADAPTER

CPVC GROOVED COUPLING ADAPTER

(GROOVE X SLIP)

CPVC BACK-TO-BACK SPRINKLER

HEAD ADAPTER

SPIGOT SPRINKLER HEAD ADAPTER

(SLIP X FIPT)

FEMALE SPRINKLER HEAD ADAPTER

(EAST)

FEMALE SPRINKLER HEAD ADAPTER

(WEST)

CPVC SPRINKLER HEAD 90° ELBOW

1716

Page 17: Tyco Fire Rapid Response Product Guide_5 2015

The Rapid Response Residential Fire Sprinkler System features CPVC Pipe and Fittings manufactured with Lubrizol’s BlazeMaster® compound – listed by Underwriters Laboratories, Inc. for use in:

• Light hazard occupancies as defined in the Standard for Installation of Fire Sprinkler Systems, NFPA 13

• Residential occupancies as defined in the Standard for Installation of Fire Sprinkler Systems in Residential Occupancies up to Four Stories in Height, NFPA 13R

• Residential occupancies as defined in the Standard for Fire Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes, NFPA 13D

• Air plenums, as defined by the Installation of Air Conditioning and Ventilating Systems, NFPA 90A and model mechanical codes

• Underground water pressure service, NFPA 24

• Unfinished basements

(Note: for complete listing and approval information, please refer to the installation instructions and technical manual No. 19-1.0.)

CPVC Pipe & FittingsAlways refer to the technical data sheet for complete description and all listing criteria, design parameters, installation instructions, care and maintenance guidelines and our limited warranty.

Install With ConfidenceTyco BlazeMaster® CPVC Piping Systems are UL and cUL listed, FM approved, and exceed ASTM standards. Benefits over traditional piping systems include:

• Resistant to rust, scale and foreign contaminant buildup

• Superior flow characteristics for increased hydraulic capabilities (C-Factor=150)

• Easily transported, handled and modified on site

• Can be easily connected to copper and steel piping

• Resist sweating and condensation

• Immune to Microbiologically Influenced Corrosion (MIC)

Fire Performance• CPVC has an LOI (Limited Oxygen Index) that is

better than wood, PVC, PB or other common building materials. It will not support combustion; therefore, it cannot be the source of a fire or cause a fire to spread.

• Does not contribute to flashover

• Low smoke generation

• Toxicity is extremely low when compared with common building and finishing materials; equal to wood and less than wool or cotton (University of Pittsburgh protocol)

CPVC PIPE (3/4” — 3”)

CPVC CROSS

CPVC ELBOW 90°

CPVC ELBOW 45° CPVC REDUCING TEE

CPVC COUPLING

CPVC REDUCING COUPLING

CPVC BUSHING

CPVC CAP

CPVC TEE

BACK-TO-BACK CROSS SPRINKLER

HEAD ADAPTER

CPVC TO COPPER-FEMALE ADAPTER (SLIP X FEMALE)

CPVC MALE ADAPTER

CPVC GROOVED COUPLING ADAPTER

(GROOVE X SLIP)

CPVC BACK-TO-BACK SPRINKLER

HEAD ADAPTER

SPIGOT SPRINKLER HEAD ADAPTER

(SLIP X FIPT)

FEMALE SPRINKLER HEAD ADAPTER

(EAST)

FEMALE SPRINKLER HEAD ADAPTER

(WEST)

CPVC SPRINKLER HEAD 90° ELBOW

1716

Page 18: Tyco Fire Rapid Response Product Guide_5 2015

TFP2015010Copyright © 2014-2015  Tyco Fire Products LP. All Rights Reserved.

WORLDWIDE HEADQUARTERS Tyco Fire Protection Products

1400 Pennbrook Parkway Lansdale, PA 19446

215-362-0700, 800-523-6512 Fax 215-362-5385

www.tyco-fire.com

UNITED STATES DISTRIBUTION CENTERS Norcross, GA Norristown, PA

Jessup, MD Carol Stream, IL

Coppell, TX Kent, WA Avon, MA

Pompano Beach, FL Murray, UT Parma, OH

Kansas City, MO

CANADA REGIONAL HEADQUARTERS 871 Equestrian Court, Unit 1A 2nd Fl.

Oakville, ON L6L 6L7

UNITED KINGDOM Regional Headquarters

Grimshaw Lane, Newton Heath Manchester M40 2WL

www.tyco-rapidresponse.com 1-877-GET-TYCO (1-877-438-8926)