    GENERAL SPECIFICATIONS

    PROJECT TITLEPROPOSED TWO-STOREY RESIDENTIALCLIENTLOCATION

    A. GENERAL CONDITIONS

    1. Under this section this paper shall be known as the standard specifications for

    and shall be the basis of interpretation of the plan for the proposed TWO-STOREY

    RESIDENCE.

    2. These specifications shall be part and parcel of the attached plans hereto and

    shall govern over the said plans in case of conflict.

    B. CLEARING, GRADING AND FILLING

    1. General Conditions

    The contractor shall make all necessary excavation for the foundation to grade

    indicated in the drawings with put extra compensation. The ground floor shall be 0.20

    meters above the grade line.

    Excavation for footings shall be done strictly in accordance with the given sizes

    and depths as shown in the drawings.

    C. PLANS AND SPECIFICATIONS

    1. The plans and specifications shall be considered as binding in all items of work

    mentioned in one but mentioned or indicated in the other or vice-versa, shall Be

    considered as there are duly mentioned in both.

  • 8/10/2019 Two storey General Specifications

    2/7

    2. Where no numerical indications appear on the plans, all drawings shall be

    carefully followed according to the plans and specifications indicated, but where

    numerical notations are indicated, such numerical notations shall be followed.

    3. The contractor or workmen without prior approval of the architect concerned and

    owner or his representative shall make no change in the drawings or specifications.

    D. CONCRETE AND MASONRY

    1. CONCRETE WORKS

    All concrete works shall be done in accordance with Government Specifications

    for Concrete and or the latest edition of the ACI requirements for Reinforced Concrete.

    The following proportions shall be used unless otherwise noted in the plan:

    Class A (1:2:4) for suspended slab, column, beams, carport slab and driveway

    Class B(1:2:5) for footings and foundations.

    Class C (1:3:6) for all slab on fill.

    All slab not less than 0.10 m in thickness. All slab reinforcement shall be 0.10 m

    in thickness. All slab reinforcement shall be 0.02 m. clear from the bottom and 0.015 m.

    clear from the top of the slab.

    2. MASONRY WORKS:

    For all exterior walls use 6concrete hollow blocks locally manufactured All 6

    hollow blocks shall be reinforced with 10 mm diameter vertical bars at every 0.60 mmand 10mm diameter horizontal bars 0.60 m and 10mm diameter horizontal bars at every

    0.60m. All 4 hollow blocks shall be reinforced with 10 mm diameter vertical bars at

    every 0.60 m and 10 mm. diameter horizontal bars at every 0.60 m.

    All cells and joints for reinforcements shall be filled with mortar. All cells and

    joints under the ground shall be filled

    Tie beam shall be provided all around exterior walls.

    For mortar and plastering, the proportion 1:3 shall be used for cement and sand

    mixture.

    3. MATERIALS

    Island cement shall conform to ASTM standards. Use only one brand for

    the whole structural and masonry works.

    Fine aggregates for concrete, mortar, grout, or plaster: stone screenings

    or other materials with similar characteristics: clean, hard, strong, durable,

    free from dusts, lumps soft or flaky particles, shale, alkali, loam or clay.

  • 8/10/2019 Two storey General Specifications

    3/7

    Coarse Aggregates: Gravel; Well- drained, clean, hard particles of gravel

    or crushed rocks, 25mm (1) dia. Maximum for slab. Clean, washed sand

    from Porac Plaridel or approved equal.

    Steel reinforcements: As manufactured by National Steel Corporation or

    approved equal. Structural Grade Steel: with minimum Fy= 227.37 MPa.

    (3300 Psi), Intermediate Grade Steel: with minimum Fy= 275.8 MPa

    (4000 psi)

    Tie wires: Ga. 16 galvanized iron (G.I.) at joints or laps of placed

    reinforcements as indicated in the plans. Refer to structural plans and

    general construction notes to conform the above values. Use steel

    conforming to ASTM standards, deformed, for concrete and masonry

    requirements.

    Water: Fit for drinking, free from injurious amount of oil, acids, alkali,

    organic materials and other deleterious substances.

    4. FORMWORKS

    Construct all formwork complete with centering coarse molds conform to

    shape, form line grade, maintain rigid to prevent deformation under I load.

    Provide necessary camber.

    Remove forms according to the following schedule:

    Footings - 2 days

    Column - 4 daysBeams & Girders --allow one day per ft. with minimum of 7 days.

    5. PROPORTIONING, MIXING AND CURVING

    The design was based on a 3,000 lbs. concrete. Design mix proportion to

    produce 3,000 lbs. strength after 28 days. Proportion volume of 2 cu. Ft. boxes.

    Immediately after placing, protect concrete surface not covered by form from lots

    of surface moisture for at least 5 clays. Protect from loss of water by covering

    with paper.

  • 8/10/2019 Two storey General Specifications

    4/7

    6. CONCRETE WALLS

    a. All walls to be reinforced according to the schedule of wall reinforcement

    unless otherwise indicated.

    b. Reinforced bars to be 0.03 meters clear from the face of the wall except

    in 0.10 meters wall where it will be at the center.

    c. Carry the vertical bars 0.60 meters above the floor level to provide the

    splicing within the necessary; elsewhere stop at 0.05 mete below the top of the

    slab or solid band.

    d. Horizontal and vertical bars, if necessary, shall be applied by lapping a

    distance equal to 40 diameters. Wire securely with #16 F.1 wire provided the

    splicing in the adjacent bars are staggered at least 1.50 meters on center.

    e. All walls spanning, openings and wall acting as beams to have vertical

    reinforcement bent U-form like stirrings and spaced according to the schedule of

    wall reinforcement, unless otherwise stated.

    f. In wall reinforcement, alternate intersection of vertical and horizontal bare

    shall be connected with #16 C.I. wire to the opposite intersection to give the

    required distance in accordance with the notes on concrete walls.

    5. SLABS

    a. All slabs reinforcement to be 0.02 meters clear from the bottom and 0.15

    meters clear from the top of the slab.

    b. Bend bars at 30 degrees angle.

    c. Use #3 dia. temperature bar.

    d. Spaced 12" o.c. both ways.

    6. CEMENT FINISHES

    a. All concrete surfaces including those indicated as cement finish, other

    than floors and steps and surfaces where other applied finish is required shall be

    given a finish done and applied in the following manner:

    1. Immediately after removal of forms, all projecting wire and bolts

    and other devices used for tying forms shall be cut-off at least one-half

    cm. beneath the finish surface. All holes, voids, depressions, and other

    defects shall be thoroughly wetted and then painted up solid with cement

    mortar putty of the same proportion as the mortar in the bodywork.

    2. Where tiles bricks are specified in drawings, tiles shall be firmly

    laid on 1:2 cement mortar.

  • 8/10/2019 Two storey General Specifications

    5/7

    7. CONCRETE HOLLOW BLOCKS

    Concrete hollow blocks are indicated in the drawings shall be jackbilt or

    equivalent. The normal thickness of the blocks shall be 6" and 4" required.

    Concrete blocks shall be wetted thoroughly with water prior to laying.

    Blocks shall be laid in running hand with vertical faces truly vertical with clean out

    joints.

    Partitions shall be reinforced with 3/8" dia. horizontal @ 24 o.c. and 1/2"

    dia. vertical @ 12 o.c. The cell containing the vertical reinforcement shall be filled

    with cement mortar of 1:3 mixture.

    8. CARPENTRY AND JOINERY WORKS

    a. Lumber shall be of approved quality of their respective kinds required forthe various parts of the work; they shall well-seasoned thoroughly dry and free

    from all imperfections impairing their strength, durability or appearance. Form

    lumber shall be rough smoothly dressed and well sandpapered.

    Lumber to be used for their respective parts of the work shall be as

    follows:

    1. Yakal - door jambs, door heads, window jambs, sills and heads

    concrete or masonry works.

    2. Tanguile - 1/4" plywood (Class C).

    b. All frames shall be done as far as possible with carefully fitted mortise

    and tendon joints. All doors, windows and other openings were so indicated on

    plane, shall have frame and still of the dimensions shown and all frames coming

    in contract with concrete shall be anchored with 20 D nails, space not more than

    3 apart, all around and the contract surface.

    All frames shall be riveted and molded were so required.

    c. Doors

    Door panels shall be as indicated in the schedule nailed and glued in

    place.

    Deutsche Fenster PVC door shall have door jamb and lockset. Schedule

    of door is provided on the plan and bill of materials. All materials shall be of good

    quality, and any objects noticed shall be out rightly rejected upon delivery.

    Glass door shall be provided with handle and hinges as specified by the

    Architect.

  • 8/10/2019 Two storey General Specifications

    6/7

    d. Windows

    All aluminum, sliding windows, jalousies shall be in accordance with the

    detailed drawing.

    Windows schedule is provided on the bill of materials.

    All window frames are aluminum powder coated with thick glass, color

    of frame as per architects or owners choice.

    e. Partitions

    Partitions shall be accordance with the detailed drawings.

    f. Ground Floor

    1. Living area - (vinyl wood plank 4 x 36 x 3mm)

    2. Dining area - (vinyl wood plank 4 x 36 x 3mm)

    3. Kitchen - (ceramic floor tiles 400mm x 400mm)

    4. Dirty Kitchen(stone tiles 600mm x 1200mm)

    5. Toilet & Bath(ceramic tile 200mm x 200mm\)

    6. Carport(stone tiles 600mm x 1200mm)

    7. Entry porch(vinyl wood plank 4 x 36 x 3mm)

    8. Maids room plain finished cement

    g. Second Floor

    1. Hallway - (vinyl wood plank 4 x 36 x 3mm)

    2. Bedroomscarpet

    3. Master bedroomcarpet

    4. Walk-in Closet - carpet

    5. Toilet & Bath(ceramic tile 200mm x 200mm)

    6. Balcony(stone tiles 600mm x 600mm)

    II. Painting

    GENERAL

    Surface Examination No painting shall be done under conditions, which will

    jeopardize the quality or appearance of painting or finishing.

    Preparation All surfaces shall be in proper condition to receive the finish. All

    woodwork shall be sandpapered to smooth and finished dusted clean; all

    knotholes, pitch pockets, or sappy portions shall be shellacked or sealed with

  • 8/10/2019 Two storey General Specifications

    7/7

    wood filler. Nail holes cracks or defects shall be carefully puttied after the first

    coat. Matching the color paint or stain, all imperfection in plaster shall be filled

    with patching. Compound and smoothened off to match adjoining surfaces.

    NOTES:

    All painting and finishes shall have at least two (2) coats of Boysen paints or stain.

    No work shall be left without approval of the supervising Architect.

    CHOICE OF COLOR

    The owner must first be consulted after he has given the color scheme. No painting job

    shall be done unless it has met the approval of the owner regarding the color.

    VARNISHING

    1. All woodwork to be varnished must first be thoroughly sandpapered and all cracks

    hole, and other defects must be thoroughly and carefully filled with the first quality

    colored or white putty tinted to match the desired finish.

    2. No man-on-the-job wood filler will he allowed. It should be a first quality wood filler.

    3. Before varnishing a sample must be applied for approval of the owner.

    MISCELLANEOUSAll licenses and permits necessary for the proper construction including light connection and

    other miscellaneous fees incidental to complete the construction of the building shall be done by

    the owner. The building permit shall be at the expense of the owner.