Fold here Fold here Fold here - d3hgrlq6yacptf.cloudfront.net
Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment...
Transcript of Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment...
![Page 1: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan](https://reader033.fdocuments.us/reader033/viewer/2022051918/600a552752dad1684461af47/html5/thumbnails/1.jpg)
3036
Two-fold Quality Assessment of Global SLR Data
Toshimichi Otsubo Mihoko Kobayashi
Hitotsubashi University, Japan
19th International Workshop on Laser Ranging, Annapolis, 31 Oct 2014
Shinichirou Takakura
NTT Communications Corporation, Japan
![Page 2: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan](https://reader033.fdocuments.us/reader033/viewer/2022051918/600a552752dad1684461af47/html5/thumbnails/2.jpg)
Two-fold?
Freshness
Quality
(a) so-called “QC” Daily à Subdaily
> 10 cm
(b) long-term QC ~ 1 year
a few mm
![Page 3: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan](https://reader033.fdocuments.us/reader033/viewer/2022051918/600a552752dad1684461af47/html5/thumbnails/3.jpg)
Two-fold QC
(a) Fresh (but less precise) So-‐called “QC”. 1 to 2 weeks span. Pass-‐by-‐pass biases derived from POD residuals. HIT-‐U: 6-‐hourly report being issued. Auto-‐detecNon &
noNficaNon implemented. SARAL added. EffecNve way to quickly find large-‐scale (> 10 cm) errors.
(b) Precise (but less fresh) Long-‐term analysis (~ 1 year). Already demonstrated with intensity and calibraNon
(2005-‐06). Wrt new components. EffecNve way to find systemaNc errors at a mm level.
![Page 4: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan](https://reader033.fdocuments.us/reader033/viewer/2022051918/600a552752dad1684461af47/html5/thumbnails/4.jpg)
http://geo.science.hit-u.ac.jp/slr/bias/
![Page 5: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan](https://reader033.fdocuments.us/reader033/viewer/2022051918/600a552752dad1684461af47/html5/thumbnails/5.jpg)
![Page 6: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan](https://reader033.fdocuments.us/reader033/viewer/2022051918/600a552752dad1684461af47/html5/thumbnails/6.jpg)
Two-fold QC
(a) Fresh (but less precise) So-‐called “QC”. 1 to 2 weeks span. Pass-‐by-‐pass biases derived from POD residuals. HIT-‐U: 6-‐hourly report being issued. Auto-‐detecNon &
noNficaNon implemented. SARAL added. EffecNve way to quickly find large-‐scale (> 10 cm) errors.
(b) Precise (but less fresh) Long-‐term analysis (~ 1 year). Already demonstrated with intensity and calibraNon
(2005-‐06). Wrt new components. EffecNve way to find systemaNc errors at a mm level.
ILRS Global Performance Card falls into this category. See Torrence’s poster.
![Page 7: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan](https://reader033.fdocuments.us/reader033/viewer/2022051918/600a552752dad1684461af47/html5/thumbnails/7.jpg)
QC (b): Sorting parameters Test #1: Single-‐shot returns per NP bin
Test #2: Single-‐shot RMS in a NP bin
Test #3: System delay (calibraNon)
Test #4: Time to the nearest calibraNon
Test #5: Range rate
Test #6: Time of day
![Page 8: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan](https://reader033.fdocuments.us/reader033/viewer/2022051918/600a552752dad1684461af47/html5/thumbnails/8.jpg)
Calibration not working properly
Test #3: System delay (calibraNon)
![Page 9: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan](https://reader033.fdocuments.us/reader033/viewer/2022051918/600a552752dad1684461af47/html5/thumbnails/9.jpg)
Test #5: Range rate
Time bias (> a few µs) suspected.
![Page 10: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan](https://reader033.fdocuments.us/reader033/viewer/2022051918/600a552752dad1684461af47/html5/thumbnails/10.jpg)
Day/Night range difference?
Test #6: Time of day
![Page 11: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan](https://reader033.fdocuments.us/reader033/viewer/2022051918/600a552752dad1684461af47/html5/thumbnails/11.jpg)
Visit our poster & Attend the clinic session
StaNon-‐by-‐staNon assessment available > 1000 charts in total! (To be placed on the web later) Various systemaNc trends (possible errors) detected. There is a risk of false alarm. ß POD is not perfect.
StaNon-‐Analyst interacNon Enjoy the acernoon session!
![Page 12: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan](https://reader033.fdocuments.us/reader033/viewer/2022051918/600a552752dad1684461af47/html5/thumbnails/12.jpg)