Turbo Catalogo inglese - North Filtration...TURBO HEADER TANK TECHNICAL CHARACTERISTICS COIL Coil...
Transcript of Turbo Catalogo inglese - North Filtration...TURBO HEADER TANK TECHNICAL CHARACTERISTICS COIL Coil...
DUST FILTER COMPONENTS
™
Certified Header Tank
Electronic controlSystems
Pulse Valvesfor Dust Collector Filters
2 0 0 8
TURBO
TEAM
Technical Development
1
Certified
Header Tank
ACCORDING TO 2009/105/EC AND PED 97/23/EC
TURBO HEADER TANKS
2
Dust Filters Components
HEADER TANKS
TYPES
TURBO HEADER TANKS
RANGE
TURBO TANKS
Turbo can provide a complete range of header tanks for dust collector
filters, according to 2009/105/EC and 97/23/EC PED Directives.
Our tanks feature high performance coupled with long operational
lifetime and can be tailored upon customer’s requirements.
1. Steel tanks (Integral, TF, TL, TD, Pack Series)
2. Aluminium tanks (Alutank Series)
3. AISI 304&316 stainless steel tanks (Integral, TF, TL, TD Series)
A wide choice of accessories is also available including:
Blow tube, Bulkhead connector, Electrical cable assembly with Matrix system, Electropneumatic cable assem-
bly based on Turbo-Net system.
Turbo can also supply ATEX94/9 /EC certi-
fied tanks that meet the following markings:
ATEX II 2GD (zone 1 and 21)
ATEX II 3GD(zone 2 and 22).
All Turbo tanks are available in
ATEX version.
(You can find details of ATEX directive at the end of
catalogue).
ALUMINIUM (Alutank Series)
3
TANKS (Integral, TF, TL, TD, Pack Series)
STAINLESS STEEL
CARBON STEEL
TURBO HEADER TANK
TECHNICAL CHARACTERISTICS
COIL
Coil insulation Class H
DIN connector PG 9 EN 175301-803
Protection DIN connector+Coil IP 65 EN 60529
Option ATEX 94/9/CE Group II Cat. 2GD + Group II Cat. 3GD
Voltages
24V / 50-60 hz (±10%) 19VA
115V / 50-60 hz (± 10%) 19VA
230V / 50-60 hz (±-10%) 19VA
24 DC (+/- 10%) 18 Watt
VALVE CONSTRUCTION
Cover Die cast aluminium
Body Die cast aluminium
Pilot group Stainless steel
Screws Stainless steel
Diaphragm std Neoprene
Viton Diaphragm Viton
Plate Diaphragm Stainless steel
TANK
Fluids Compressed air - Nitrogen
Pressure 0,5 to 8 bar
Temperature range of carbon steel -20°C ; + 80°C
Temperature range of stainless steel -50°C ; + 200°C
Option ATEX 94/9/CE Group II Cat. 2 GD
Group II Cat. 3 GD
TANK CAPACITY
Dn 4” (114 mm) 9,5 liters/meter
Dn 5” (139 mm) 13,70 liters/meter
Dn 6” (168 mm) 20,10 liters/meter
Dn 8” (219 mm) 34,90 liters/meter
Dn 10” (273 mm) 53,50 liters/meter
Dn 12” (324 mm) 76 liters/meter
4
3
TURBO HEADER TANKS
RANGE
5
ATEX II 2GDC ATEX II 3D CE STANDARD PED STANDARD STAINLESS STEEL PED
ALUMINIUMPED
TURBO PRODUCT RANGE
- Global immersion
Global immersion tanks offer superior performance thanks to the fully immersed diaphragm.
- With threaded stub pipes
Provide a solid coupling and high alignment assembly of valves. They make use of threaded pulse valves.
- With plain tube
This version makes it possible to achieve a quick and highly efficient valve assembly.
- Aluminium tanks, Alutank Series
Fully customised upon customer’s requirements, they feature light weight and easy handing. Thanks to the anodization
process, they offer considerable protection against atmospheric agents and prevent oxidation.
Besides, they ensure the availability of totally clean compressed air supply.
TURBO HEADER TANK
GALLERY
6
A1 GLOBAL IMMERSION INTEGRAL Series 2009/105/EC - 97/23/EC PED
A2 THREADED STUB PIPE TF Series 2009/105/EC - 97/23/EC PED
A3 THREADED STUB PIPE TL Series 2009/105/EC - 97/23/EC PED
FOR STRAIGHT TROUGHT VALVE
A4 PLAIN STUB PIPE TD Series 2009/105/EC - 97/23/EC PED
A5 STAINLESS STEEL XTF Series 97/23/EC PED
A6 GLOBAL IMMERSION ALUTANK Series 97/23/EC PED
A7 AIR CANNON PACK Series 2009/105/EC - 97/23/EC PED
A8 BLOW TUBES TS Series
7
CERTIFIED HEADER TANKSAccording to 2009/105/EC and 97/23/EC PED
8
02450
TANK MODEL:
GLOBAL IMMERSION = INTEGRAL
THREADED STUB PIPE = TF - TL
PLAIN STUB PIPE = TD
ALUMINIUM = ALUTANK
N: NUMBER OF VALVES
P : PITCH
ROUND ENDS = B
FLAT ENDS = F
TANK DIAMETER
4” = 4
5” = 5
6” = 6
8” = 8
10” = 10
12” = 12
VALVE DIAMETER1/2” = 10
3/4” = 20
1” = 25
1”1/2 = 30
1”1/2 = 35
1”1/2 = 40
1”1/2 = 45
2” = 50
2”1/2 = 65
3” = 75
POWER SUPPLY
24V/50-60Hz =02450
115V/50-60Hz =11050
230V/50-60Hz =22050
24VDC =024DC
INTEGRAL PILOT = P
REMOTE PILOT = M
INTEGRAL 6 P 25 P150N10 B G1example
HEADER TANKSAccording to 2009/105/EC and PED 97/23/EC
HOW TO ORDER
BLOW TUBE
SHORT PLAIN = G1
LONG PLAIN = G2
LONG THREADED = G3
SHORT THREADED = G4
Integral 6 P 25 02450 N10 P 150 B G1 identifies a global
immersion tank (Integral) having 6” (6) diameter, integral elec-
trical pilot (P), 1” (25) valves with 24V 50Hz (02450) coil volt-
age, equipped with no. 10 valves (N10) whose pitch is 150
mm (P150).
Tank ends are round (B) and outlet stub pipes are plain (G1).
GLOBAL IMMERSION HEADER TANK A1According to 2009/105/EC and PED 97/23/EC
INTEGRAL Series dn 4” with 1/2” valves 4”
DESCRIPTION VALVE SM10/SP10
1 Coil + Din connector BH10...V/50-60Hz
2 Screws + Washers VTE6x18+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP10
5 Remote operated cover TCOP10FM
6 Spring TMOL10G
7 Diaphragm M10
9
1/2”
A1 GLOBAL IMMERSION HEADER TANKAccording to 2009/105/EC and PED 97/23/EC
5” INTEGRAL Series dn 5” with 3/4 ” valves
BRACKET
COLLAR
BRACKETS
CS = COLLAR
SA = HIGH BRACKET
SM = MEDIUM BRACKET
SB = SMALL BRACKET
G1 G2 G3 G4
SHORT PLAIN TUBE = G1
LONG PLAIN TUBE = G2
THREADED LONG TUBE = G3
THREADED SHORT TUBE = G4
DESCRIPTION VALVE SM20/SP20
1 Coil + Din connector BH10...V/50-60Hz
2 Screws + Washers TE6x18+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP25
5 Cover remote operated TCOP25FM
6 Diaphragm M25
6a Spring TMOL10G
3/4”
10
GLOBAL IMMERSION HEADER TANK A1According to 2009/105/EC and PED 97/23/EC
INTEGRAL Series dn 6” with 3/4 ” valves 6”
BRACKETS
CS = COLLAR
SA = HIGH BRACKET
SM = MEDIUM BRACKET
SB = SMALL BRACKET
BRACKET
COLLAR
G1 G3G2 G4
SHORT PLAIN TUBE = G1
LONG PLAIN TUBE = G2
THREADED LONG TUBE = G3
THREADED SHORT TUBE = G4
DESCRIPTION VALVE SM20/SP20
1 Coil + Din connector BH10...V/50-60Hz
2 Screws + Washers TE6x18+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP25
5 Remote operated cover TCOP25FM
6 Diaphragm M25
6a Spring TMOL10G
3/4”
11
A1 GLOBAL IMMERSION HEADER TANKAccording to 2009/105/EC and PED 97/23/EC
6” INTEGRAL Series dn 6” with 1” valves
BRACKETS
CS = COLLAR
SA = HIGH BRACKET
SM = MEDIUM BRACKET
SB = SMALL BRACKET
BRACKET
COLLAR
G4G2 G3G1
SHORT PLAIN TUBE = G1
LONG PLAIN TUBE = G2
THREADED LONG TUBE = G3
THREADED SHORT TUBE = G4
DESCRIPTION VALVE SM25/SP25
1 Coil + Din connector BH10...V/50-60Hz
2 Screws + Washers VTE6x18+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP25
5 Remote operated cover TCOP25FM
6 Diaphragm M25
6a Spring TMOL10G
1 ”
12
GLOBAL IMMERSION HEADER TANK A1According to 2009/105/EC and PED 97/23/EC
INTEGRAL Series dn 6” with 1”1/2 valves
BRACKETS
CS = COLLAR
SA = HIGH BRACKET
SM = MEDIUM BRACKET
SB = SMALL BRACKET
BRACKET
COLLAR
G1 G3G2 G4
SHORT PLAIN TUBE = G1
LONG PLAIN TUBE = G2
THREADED LONG TUBE = G3
THREADED SHORT TUBE = G4
DESCRIPTION VALVE SM30/SP30
1 Coil + Din connector BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP30
5 Remote operated cover TCOP30FM
6 Spring TMOL25GHS
7 Diaphragm M30
1”1/2
13
A1 GLOBAL IMMERSION HEADER TANKAccording to 2009/105/EC and PED 97/23/EC
6” INTEGRAL Series dn 6” with 1”1/2 valves
DESCRIPTION VALVE SM35/SP35
1 Coil + Din connector BH10...V/50-60Hz
2 Screws + Washers VTE6x18+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP10
5 Remote operated cover TCOP10FM
6 Spring TMOL10G
7 Diaphragm M10
8 Screws + Washers VTE6x20+TROND6GROWER
9 Cover TCOP35N
10 Spring TMOL25GHS
11 Diaphragm M35
14
BRACKETS
CS = COLLAR
SA = HIGH BRACKET
SM = MEDIUM BRACKET
SB = SMALL BRACKET
BRACKET
COLLAR
G1 G3G2 G4
SHORT PLAIN TUBE = G1
LONG PLAIN TUBE = G2
THREADED LONG TUBE = G3
THREADED SHORT TUBE = G4
1”1/2
GLOBAL IMMERSION HEADER TANK A1According to 2009/105/EC and PED 97/23/EC
INTEGRAL Series dn 8” with 1”valves 8”
BRACKETS
CS = COLLAR
SA = HIGH BRACKET
SM = MEDIUM BRACKET
SB = SMALL BRACKET
BRACKET
COLLAR
G1 G3G2 G4
SHORT PLAIN TUBE = G1
LONG PLAIN TUBE = G2
THREADED LONG TUBE = G3
THREADED SHORT TUBE = G4
DESCRIPTION VALVE SM25/SP25
1 Coil + Din connector BH10...V/50-60Hz
2 Screws + Washers VTE6x18+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP25
5 Remote operated cover TCOP25FM
6 Diaphragm M25
6a Spring TMOL10G
1”
15
A1 GLOBAL IMMERSION HEADER TANKAccording to 2009/105/EC and PED 97/23/EC
INTEGRAL Series dn 8” with 1”1/2valves
G4G2 G3G1
DESCRIPTION VALVE SM35/SP35
1 Coil + Din connector BH10...V/50-60Hz
2 Screws + Washers VTE6x18+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP10
5 Cover remote operated TCOP10FM
6 Spring TMOL10G
7 Diaphragm M10
8 Screws + Washers VTE6x20+TROND6GROWER
9 Cover TCOP35N
10 Spring TMOL25GHS
11 Diaphragm M35
8”
1”1/2
16
BRACKETS
CS = COLLAR
SA = HIGH BRACKET
SM = MEDIUM BRACKET
SB = SMALL BRACKET
BRACKET
COLLAR
GLOBAL IMMERSION HEADER TANK A1According to 2009/105/EC and PED 97/23/EC
INTEGRAL Series dn 8” with 1”1/2valves 8”
17
BRACKETS
CS = COLLAR
SA = HIGH BRACKET
SM = MEDIUM BRACKET
SB = SMALL BRACKET
BRACKET
COLLAR
G1 G3G2 G4
SHORT PLAIN TUBE = G1
LONG PLAIN TUBE = G2
THREADED LONG TUBE = G3
THREADED SHORT TUBE = G4
DESCRIPTION VALVE SM40/SP40
1 Coil + Din connector BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP25
5 Remote operated cover TCOP25FM
6 Diaphragm M25
6a Spring TMOL10G
7 Screws + Washers VTE8x20+TROND8GROWER
8 Cover TCOP40N
9 Spring TMOL40
10 Diaphragm M40
1”1/2
A1 GLOBAL IMMERSION HEADER TANKAccording to 2009/105/EC and PED 97/23/EC
INTEGRAL Series dn 8” with 1”1/2valves
DESCRIPTION VALVE SM45/SP45
1 Coil + Din connector BH10...V/50-60Hz
2 Screws + Washers VTE6x18+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP10
5 Cover remote operated TCOP10FM
6 Spring TMOL10G
7 Diaphragm M10
8 Screws + Washers VTE8x20+TROND8GROWER
9 Cover TCOP45N
10 Spring TMOL40
11 Diaphragm M45
8”
18
BRACKETS
CS = COLLAR
SA = HIGH BRACKET
SM = MEDIUM BRACKET
SB = SMALL BRACKET
BRACKET
COLLAR
G1 G3G2 G4
SHORT PLAIN TUBE = G1
LONG PLAIN TUBE = G2
THREADED LONG TUBE = G3
THREADED SHORT TUBE = G4
1”1/2
GLOBAL IMMERSION HEADER TANK A1According to 2009/105/EC and PED 97/23/EC
INTEGRAL Series dn 10” with 1”1/2 valves 10”
19
DESCRIPTION VALVE SM40/SP40
1 Coil + Din connector BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP25
5 Remote operated cover TCOP25FM
6 Diaphragm M25
6a Spring TMOL10G
7 Screws + Washers VTE8x20+TROND8GROWER
8 Cover TCOP40N
9 Spring TMOL40
10 Diaphragm M40
BRACKETS
CS = COLLAR
SA = HIGH BRACKET
SB = SMALL BRACKET
BRACKET
COLLAR
G1 G3G2 G4
SHORT PLAIN TUBE = G1
LONG PLAIN TUBE = G2
THREADED LONG TUBE = G3
THREADED SHORT TUBE = G4
1”1/2
A1 GLOBAL IMMERSION HEADER TANKAccording to 2009/105/EC and PED 97/23/EC
INTEGRAL Series dn 10” with 2” valves
DESCRIPTION VALVE SM50/SP50
1 Coil + Din connector BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP25
5 Remote operated cover TCOP25FM
6 Diaphragm M25
6a Spring TMOL10G
7 Screws + Washers VTE10x25+TROND10GROWER
8 Cover TCOP50G
9 Spring TMOL40
10 Diaphragm M50
10”
20
BRACKETS
CS = COLLAR
SA = HIGH BRACKET
SB = SMALL BRACKET
BRACKET
COLLAR
G1 G2 G3 G4
SHORT PLAIN TUBE = G1
LONG PLAIN TUBE = G2
THREADED LONG TUBE = G3
THREADED SHORT TUBE = G4
2”
GLOBAL IMMERSION HEADER TANK A1According to 2009/105/EC and PED 97/23/EC
INTEGRAL Series dn 12” with 2”1/2 valves 12”
DESCRIPTION VALVE SM65/SP65
1 Coil + Din connector BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP25
5 Cover remote operated TCOP25FM
6 Diaphragm M25
6a Spring TMOL10G
7 Screws + Washers VTE10x25+TROND10GROWER
8 Cover TCOP65G
9 Spring TMOL40
10 Diaphragm M76/SERB
2” 1/2
21
A1 GLOBAL IMMERSION HEADER TANKAccording to 2009/105/EC and PED 97/23/EC
INTEGRAL Series dn 12” with 3” valves
DESCRIPTION VALVE SM75/SP75
1 Coil + Din connector BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP25
5 Remote operated cover TCOP25FM
6 Diaphragm M25
6a Spring TMOL10G
7 Screws + Washers VTE10x25+TROND10GROWER
8 Cover TCOP65G
9 Spring TMOL40
10 Diaphragm M76/SERB
12”
3”
22
23
Technical Development
A2 HEADER TANK WITH THREADED STUB PIPES According to 2009/105/EC and PED 97/23/EC
TF SERIES dn 5” - 6” - 8” - 10” - 12”TF
24
Ø (Nom.) Ø (est)mm ØE A B(min) ØF H M R Z(±) S(±) P(min)
5” 140 3/4” 50 45 1” 10 85 40 120 190 85
5” 140 1” 50 45 1” 10 85 40 120 190 85
6” 168,3 3/4” 50 45 1” 10 85 40 120 204 85
6” 168,3 1” 50 45 1” 10 85 40 120 204 85
6” 168,3 1”1/2 50 55 1” 10 85 40 136 220 150
8” 219,1 1” 70 45 1”1/2 10 85 40 120 229 85
8” 219,1 1”1/2 70 55 1”1/2 10 85 40 136 245 150
8” 219,1 2” 70 60 1”1/2 10 85 40 164 273 210
10” 273 1”1/2 90 55 1”1/2 12 85 40 136 272 150
10” 273 2” 90 60 1”1/2 12 75 40 164 300 210
10” 273 21/2 90 70 1”1/2 12 75 40 164 300 210
12” 324 2” - 60 1”1/2 20 75 40 164 325 210
12” 324 2”1/2 - 65 1”1/2 20 75 40 164 325 210
DESCRIPTION VALVE FM20/FP20 VALVE FM25/FM25
1 Coil + Din connector BH10...V/50-60Hz BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER VTE6x20+TROND6GROWER
3 Pole assembly GPC10 GPC10
4 Cover direct drive TCOP25 TCOP25
5 Remote operated cover TCOP25FM TCOP25FM
6 Diaphragm M25 M25
6a Spring TMOL10G TMOL10G
7 Body TCOR20FFG TCOR25FFG
DESCRIPTION VALVE FP/FM40 VALVE FM55/FP55 VALVE FM65/FP65
1 Coil + Din connector BH10...V/50-60Hz BH10...V/50-60Hz BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER VTE6x20+TROND6GROWER VTE6x20+TROND6GROWER
3 Pole assembly GPC10 GPC10 GPC10
4 Cover direct drive TCOP25 TCOP25 TCOP25
5 Remote operated cover TCOP25FM TCOP25FM TCOP25FM
6 Diaphragm M25 M25 M25
6a Spring TMOL10G TMOL10G TMOL10G
7 Screws + Washers VTE8x20+TROND8GROWER VTE10x25+TROND10GROWER VTE10x25+TROND10GROWER
8 Cover TCOP40N TCOP65G TCOP65G
9 Spring TMOL40 TMOL40 TMOL40
10 Main diaphragm M40 M55/LP M76
11 Body TCOR40FFG TCOR55FFG TCOR65FFGP 25
THREADED STUB PIPE HEADER TANK A2According to 2009/105/EC and PED 97/23/EC
TF Series dn 5” - 6” - 8” - 10” - 12” TF
26
From R.&D. a new pulse valve
THE DESIGN OFFERS EASE
OF MAINTENANCE THANKS
TO HORIZONTAL POSITION
INTEGRATED COMPRESSION FITTING
CONNECTOR ELIMINATES THE NEED FOR SEPARATE
BULKHEAD CONNECTOR
SAVING & FLEXIBILITYThe double advantage solution!
SAVING & FLEXIBILITYThe double advantage solution!
27
DIRECT INSTALLATION THROUGH
THE BAG HOUSE WALL
SAME COMPONENTS THROUGH ALL
TURBO PULSE VALVES RANGE
A3 HEADER TANK WITH THREADED STUB PIPES According to 2009/105/EC and PED 97/23/EC
TL Series dn 6”- 8” straight through dn1” -11/2“TL
Ø Ø (est) mm øE A B(min) ØF H M R Z(± S(±) P(min) Mounting bracket
6” 168,3 1”1/4 50 50 1” 10 45 30 139 223 85 S6-223
6” 168,3 2” 50 60 1” 10 45 30 180 265 120 S6-265
8” 219,1 2” 70 60 1”1/2 10 45 30 180 290 120 S8-290
28
DESCRIPTION VALVE FDM25/FDP25
1 Coil + Din connector BH10...V/50-60Hz
2 Screws + Washers VTE6x20 + TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP25
5 Cover remote operated TCOP25FM
6 Diaphragm M25
6a Spring TMOL10G
7 Body TCOR25FLG
8 Gasket TRON80x53x5
9 Lock nut TGBA25
10 Conical seal GCON25
11 Retainer ring OG25
12 Compression nut TDAL25
DESCRIPTION VALVE FDM35/FDP35
1 Coil + Din connector BH10...V/50-60Hz
2 Screws + Washers VTE6x18 + TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP10
5 Cover remote operated TCOP10FM
6 Spring TMOL10G
7 Diaphragm M10
8 Screws + Washers VTE6x20 + TROND6GROWER
9 Cover TCOP35N
10 Spring TMOL25GHS
11 Diaphragm M35
12 Body TCOR35FLG
13 Gasket TRON100x70x5
14 Lock nut TGBA40
15 Conical seal GCON40
11 Retainer ring OG40
12 Compression nut TDAL40
29
THREADED STUB PIPE HEADER TANK A3According to 2009/105/EC and PED 97/23/EC
TL Series /Part List TL
A4 HEADER TANK WITH PLAIN STUB PIPESAccording to 2009/105/EC and PED 97/23/EC
TD Series dn 5” - 6” - 8” - 10”TD
Ø (NOM) Ø(est)mm ØE A B(min) ØF H M Z(±) S(±) P(min)
5” 140 3/4” 50 45 1” 10 85 130 200 85
5” 140 1” 50 45 1” 10 85 130 200 85
6” 168,3 3/4” 50 45 1” 10 85 130 215 85
6” 168,3 1” 50 45 1” 10 85 130 215 85
6” 168,3 1”1/2 50 55 1” 10 85 138 223 150
8” 219,1 1” 70 45 1”1/2 10 85 130 240 85
8” 219,1 1”1/2 70 55 1”1/2 10 85 138 248 150
10” 273 1”1/2 90 55 1”1/2 12 85 138 275 150
30
HEADER TANK WITH PLAIN STUB PIPE A4According to 2009/105/EC and PED 97/23/EC
TD Series dn 5” - 6” - 8” - 10” TD
DESCRIPTION VALVE DM20/DP20 VALVE DM25/DP25
1 Coil + Din connector BH10...V/50-60Hz BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER VTE6x20+TROND6GROWER
3 Pole assembly GPC10 GPC10
4 Cover direct drive TCOP25 TCOP25
5 Remote operated cover TCOP25FM TCOP25FM
6 Diaphragm M25 M25
6a Spring TMOL10G TMOL10G
7 Body TCOR20/25MMG TCOR25MMG
8 Conical seal GCON20 GCON25
9 Retainer ring OG20 OG25
10 Compression nut TDAL20/25 TDAL25
DESCRIPTION VALVE DM40/DP40
1 Coil + Din connector BH10...V/50-60Hz
2 Screws + Washers VTE6x20 + TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP25
5 Remote operated cover TCOP25FM
6 Diaphragm M25
6a Spring TMOL10G
7 Screws + Washers VTE8x20 + TROND8GROWER
8 Cover TCOP40N
9 Spring TMOL40
10 Main diaphargm M40
11 Body TCOR40MMG
12 Conical seal GCON40
12 Retainer ring OG40
13 Compression Nut TDAL40
31
A5 STAINLESS STEEL HEADER TANKS WITH THREADED STUB PIPESAccording to PED 97/23/EC
XTF XTF Series dn 5” - 6” - 8”
32
Ø (nom) Ø (est) mm ØE A B (min) ØF H M R Z (±) S (±) P (min)
5” 140 3/4” 50 40 1” 15 85 40 120 190 85
5” 140 1” 50 45 1” 15 85 40 120 190 85
5” 140 11/2” 50 50 1” 15 85 40 120 190 150
6” 168,3 3/4” 50 40 1” 15 85 40 120 204 85
6” 168,3 1” 50 45 1” 15 85 40 120 204 85
6” 168,3 11/2” 50 50 1” 15 85 40 136 220 150
6” 168,3 2” 50 60 1” 15 85 40 164 248 210
8” 219,1 1” 70 45 11/2” 18 85 40 120 229 85
8” 219,1 11/2” 70 55 11/2” 18 85 40 136 245 150
8” 219,1 2” 70 60 11/2” 18 85 40 164 273 210
8” 219,1 21/2” 70 65 11/2” 18 85 40 164 273 210
Temp. Range: -50°C +200°C
A5 STAINLESS STEEL GLOBAL IMMERSION HEADER TANKAccording to PED 97/23/EC
XTF INTEGRAL Series dn 5” - 6” - 8”
Temp. Range: -50°C +200°C
MOUNTING BRACKETS A5
RANGE
33
DN Tank Type of bracket Code of the bracket A (mm) B (mm) H (mm) S (mm)
Small bracket SB5 264 150 95 50
5” (Ø 139,7) Medium bracket SM5 264 150 160 50
High bracket SA5 264 150 180 50
Small bracket SB6 292 150 109 50
Medium bracket SM6 292 150 170 50
6” (Ø 168,3) High bracket SA6 292 150 200 50
Series TL bracket S6-223 292 150 223 50
Series TL bracket S6-265 292 150 265 50
Small bracket SB8 348 200 134 50
8” (Ø 219,1) Medium bracket SM8 348 200 210 50
High bracket SA8 348 200 270 50
Series TL bracket S8-290 348 200 290 50
10” (Ø 273) Small bracket SB10 424 250 161 50
High bracket SA10 424 250 273 50
A6 ALUMINIUM GLOBAL IMMERSION HEADER TANKAccording to PED 97/23/EC
ALUTANK Series with dn 1” valves
AIR PRESSURE B
BAIR PRESSURE
UV CP
G1 G4G3G2
SHORT PLAIN TUBE = G1
LONG PLAIN TUBE = G2
THREADED LONG TUBE = G3
THREADED SHORT TUBE = G4
TECHNICAL CARECTERISTICS
•TankExtruded anodized aluminium
•EndsDie cast aluminium
•Blow tubeSteel zinc plated
•O-RingsNBR
•Temperature range-20°C +80°C
•Operating pressure0,5 ÷ 6 BAR - 0,5÷ 8 BAR
•Low temperature- 40°C +80°C
Blow tubes in Aluminium
DESCRIPTION VALVE SQM25/SQP25
1 Coil + Din connector BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP25
5 Remote operated cover TCOP25FM
6 Diaphragm M25
6a Spring TMOL10G
7 Screws VTCEI6x16
8 Body TCOR25IMO
9 O-ring GOR65x4
6”
1”
34
AIR PRESSURE B
BAIR PRESSURE
UV CP
G1 G3G2 G4
SHORT PLAIN TUBE = G1
LONG PLAIN TUBE = G2
THREADED LONG TUBE = G3
THREADED SHORT TUBE = G4
DESCRIPTION VALVE SQM35/SQP35
1 Coil + Din connector BH10...V/50-60Hz
2 Screws + Washers VTE6x18+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP10
5 Remote operated cover TCOP10FM
6 Spring TMOL10G
7 Diaphragm M10
8 Screws + Washers VTE6x20+TROND6GROWER
9 Cover TCOP35N
10 Spring TMOL25GHS
11 Diaphragm M35
12 Screws VTCEI8x20
13 Body TCOR35FMGS
14 O-ring GOR6337
1”1/2
TECHNICAL CARECTERISTICS
•TankExtruded anodized aluminium
•EndsDie cast aluminium
•Blow tubeSteel zinc plated
•O-RingsNBR
•Temperature range-20°C +80°C
•Operating pressure0,5 ÷ 6 BAR - 0,5 ÷ 8 BAR
•Low temperature- 40°C +80°C
Blow tubes in Aluminium
35
ALUMINIUM GLOBAL IMMERSION HEADER TANK A6
According to PED 97/23/EC
Series ALUTANK with 1”1/2 valve 6”
A7 AIR CANNONAccording to 2009/105/EC and PED 97/23/EC
PACK PACK Series
36
Type A B C E Ø F G Ø H I L M N Ø O Ø P Q
PACK 5 512 140 (ø5”) 100 100 3/4” 90 73 38 232 150 120 13 1/2” 250
PACK 15 868 168,3 (ø6”) 124 100 1” 90 73 38 368 280 160 13 1/2” 250
PACK 25 895 219,1 (ø8”) 160 150 1”1/2 133,5 135 62 375 320 260 13 1/2” 350
PACK 50 1174 273 ( ø10”) 214 185 2” 198 190 83 539 320 260 13 1/2” 350
37
BLOW TUBE A8
TS SERIES TS
D10 L150 F200 H15 A2 T2
TS: BLOW TUBE
P: INJECTOR PITCH
N: Q.TY OF INJECTOR
D: INJECTOR DIAMETER
H: INJECTOR HEIGHT
L: DISTANCE BETWEEN FILTER WALL
AND INJECTOR
A1: PLAIN
A2: THREADED
T1: PLUG
T2: BRACKET
F: DISTANCE BETWEEN INJECTOR
TO END OF B.T.
HOW TO ORDERTS 25 P100 N10
A1
A2
T1
T2
DESCRIPTION
1 Tube
2 Injector
3 O-Ring
4 Plug
5 Bracket
6 Screws
Ø D: BLOW TUBE DIAMETER
20 3/4”
25 1”
40 1”1/2
50 2”
38
PULSE VALVES
Pulse
Valvesfor Dust Collector Filters
39
TURBO PULSE VALVES
40
R&D
TURBO VALVES
Turbo has a complete range of pulse valves for dust collector filters able to meet all customers technical requirement.
Turbo valves are designed to have a long life and excellent performance in terms of opening and closing with low air
consumption.
Turbo products range includes:
1 - Threaded pulse valves (F Series)
2 - Compression fittings pulse valves (D Series)
3 - Flanged pulse valves (E Series)
4 - Pulse valves for square tank (SQ Series)
5 - Straight through pulse valves (FD Series)
Same valves are available in compliance with ATEX 94/9/EC:
ATEX II 2 GD (zone 1 and 21)
ATEX II 3 GD (zone 2 and 22).
(You can find details of ATEX directive at the end of catalogue).
TURBO PULSE VALVES
RANGE
41
02450
F : THREADED VALVE
D : COMPRESSION FITTINGS VALVE
E : FLANGED VALVE
SQ : GLOBAL VALVE FOR SQUARE TANK
FD : STRAIGHT THROUGH VALVE
STANDARD VOLTAGES
24V/50-60Hz =02450
115V/50-60Hz =11050230V/50-60Hz =2205024VDC =024DC
P = INTEGRAL PILOT
M = REMOTE PILOT
F P 25example
PULSE VALVES
HOW TO ORDER
CONNECTION DIAMETERS
3/4” = 201” = 251”1/2 = 401”1/2 = 452” = 552”1/2 = 653” = 754” = 100
42
Dust Filters Components
PULSE VALVES
B1 Pulse valve with threaded connection F Series
B2 Pulse valves with compression fitting D Series
B3 Pulse valves with flange inlet E Series
B4 Pulse valves for square tank SQ Series
B5 Pulse valves straight through FD Series
43
B1 THREADED PULSE VALVE
F F Series
44
CHARACTERISTICS
Fluid Filtered and oilfree compressed air
Temperature STD diaphragm -20°C; +80°Crange Viton diaphragm -20°C; +200°C
Operating pressure min 0,5 bar - max 7,5 bar
Body and cover Die cast aluminium
Core tube Stainless steel
Plunger Stainless steel
Screws Stainless steel
Coil insulation Class H
Din’s connector PG 9 EN175301-803
Protection Din’s connector + Coil IP65 EN60529
Standard voltage 24V/50-60Hz (±10%) 19VA
115V/50-60Hz (±10%) 19VA
230V/50-60Hz (±10%) 19VA
24VDC (± 10%) 18 Watt
DESCRIPTION VALVE FM20/FP20 VALVE FM25/FP25
1 Coil +Din Connector BH10...V/50-60Hz BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER VTE6x20+TROND6GROWER
3 Pole assembly GPC10 GPC10
4 Cover direct drive TCOP25 TCOP25
5 Remote operated cover TCOP25FM TCOP25FM
6 Diaphragm M25 M25
6a Spring TMOL10G TMOL10G
7 Body TCOR20FFG TCOR25FFG
FP Integral solenoid pilot version / FM Remote pilot version
DESCRIPTION VALVE FM40/FP40 VALVE FM55/FP55 VALVE FM65/FP65
1 Coil + Din Connector BH10...V/50-60Hz BH10...V/50-60Hz BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER VTE6x20+TROND6GROWER VTE6x20+TROND6GROWER
3 Pole assembly GPC10 GPC10 GPC10
4 Cover direct drive TCOP25 TCOP25 TCOP25
5 Remote operated cover TCOP25FM TCOP25FM TCOP25FM
6 Diaphragm M25 M25 M25
6a Spring TMOL10G TMOL10G TMOL10G
7 Screws + Washers VTE8x20+TROND8GROWER VTE10x25+TROND10GROWER VTE10x25+TROND10GROWER
8 Cover TCOP40N TCOP65G TCOP65G
9 Spring TMOL40 TMOL40 TMOL40
10Main diaphragm M40 M55/LP M76
11 Body TCOR40FFG TCOR55FFG TCOR65FFGP
FP Integral solenoid pilot version / FM Remote pilot version
THREADED PULSE VALVE B1
Overall dimensions / F Series F
45
Model Ø L (nom) A B C D E Weight (Kg)
FP 20 3/4“ 52 90 20,5 74 ~125 0,6
FP 25 1“ 52 90 20,5 74 ~125 0,5
FP 40 1”1/2 71,3 135 31 140 ~188 1,6
FP 55 2“ 114 203 40 194 ~225 3,7
FP 65 2”1/2 114 203 48 194 ~225 3,6
FM 20 3/4“ 52 90 20,5 74 ~67 0,4
FM 25 1“ 52 90 20,5 74 ~67 0,3
FM 40 1”1/2 71,3 135 31 140 ~130 1,4
FM 55 2“ 114 203 40 194 ~167 3,5
FM 65 2”1/2 114 203 48 194 ~167 3,4
Note: Threads can also be implemented in NPT. For information, please contact our technical Department.
B1 THREADED PULSE VALVE
F F Series
46
CHARACTERISTICS
Fluid Filtered and oilfree compressed air
Temperature STD diaphragm -20°C; +80°Crange Viton diaphragm -20°C; +200°C
Operating pressure min 0,5 bar - max 7,5 bar
Body and cover Die cast aluminium
Core tube Stainless steel
Plunger Stainless steel
Screws Stainless steel
Coil insulation Class H
Din’s connector PG 9 EN175301-803
Protection Din’s connector + Coil IP65 EN60529
Standard voltage 24V/50-60Hz (±10%) 19VA
115V/50-60Hz (±10%) 19VA
230V/50-60Hz (±10%) 19VA
24VDC (± 10%) 18 Watt
DESCRIPTION VALVE FM45/FP45
1 Coil + Din Connector BH10...V/50-60Hz
2 Screws + Washers VTE6x18+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP10
5 Remote operated cover TCOP10FM
6 Spring TMOL10G
7 Diaphragm M10
8 Screws + Washers VTE8x20+TROND8GROWER
9 Cover TCOP45N
10 Spring TMOL40
11 Diaphragm M45
12 Body TCOR40FFG
FP Integral solenoid pilot version / FM Remote pilot version
THREADED PULSE VALVE B1
Overall dimensions / F Series F
47
Model Ø L (nom) A B C D E Weight (Kg)
FP 45 1”1/2 71,3 135 31 140 ~180 1,6
FM 45 1”1/2 71,3 135 31 140 ~122 1,4
B2 COMPRESSION FITTING PULSE VALVE
D D Series
48
CHARACTERISTICS
Fluid Filtered and oilfree compressed air
Temperature STD diaphragm -20°C; +80°Crange Viton diaphragm -20°C; +200°C
Operating pressure min 0,5 bar - max 7,5 bar
Body and cover Die cast aluminium
Core tube Stainless steel
Plunger Stainless steel
Screws Stainless steel
Coil insulation Class H
Din’s connector PG 9 EN175301-803
Protection Din’s connector + Coil IP65 EN60529
Standard voltage 24V/50-60Hz (±10%) 19VA
115V/50-60Hz (±10%) 19VA
230V/50-60Hz (±10%) 19VA
24VDC (± 10%) 18 Watt
DESCRIPTION VALVE DM20/DP20 VALVE DM25/DP25
1 Coil +Din Connector BH10...V/50-60Hz BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER VTE6x20+TROND6GROWER
3 Pole assembly GPC10 GPC10
4 Cover direct drive TCOP25 TCOP25
5 Remote operated cover TCOP25FM TCOP25FM
6 Diaphragm M25 M25
6a Spring TMOL10G TMOL10G
7 Body TCOR20/25MMG TCOR25MMG
8 Conical seal GCON20 GCON 25
9 Retainer ring OG20 OG25
10Compression nut TDAL20/25 TDAL25
DP Integral solenoid pilot version / DM Remote pilot version
DESCRIPTION VALVE DM40/DP40
1 Coil + Din Connector BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP25
5 Remote operated cover TCOP25FM
6 Diaphragm M25
6a Spring TMOL10G
7 Screws + Washers VTE8x20+TROND8GROWER
8 Cover TCOP40N
9 Spring TMOL40
10 Main Diaphragm M40
11 Body TCOR40MMG
12 Conical seal GCON40
13 Retainer ring OG40
14 Compression nut TDAL40
FP Integral solenoid pilot version / FM Remote pilot version
COMPRESSION FITTING PULSE VALVE B2
Overall dimensions / D Series D
49
Model Ø L (nom) A B C E ØF G H I Weight (Kg)
DP 20 3/4“ 48 90 128 ~189 28,5 48 74 80 1,1
DP 25 1“ 48 90 128 ~189 35 48 74 80 1
DP 40 1”1/2 66 114 180 ~264 50 66 140 101 2,5
DM 20 3/4“ 48 90 128 ~131 28,5 48 74 80 1,1
DM 25 1“ 48 90 128 ~131 35 48 74 80 0,9
DM 40 1”1/2 66 114 180 ~206 50 66 140 101 2,3
B3 FLANGED PULSE VALVES
E E Series
50
CHARACTERISTICS
Fluid Filtered and oilfree compressed air
Temperature STD diaphragm -20°C; +80°Crange Viton diaphragm -20°C; +200°C
Operating pressure min 0,5 bar - max 7,5 bar
Body and cover Die cast aluminium
Core tube Stainless steel
Plunger Stainless steel
Screws Stainless steel
Coil insulation Class H
Din’s connector PG 9 EN175301-803
Protection Din’s connector + Coil IP65 EN60529
Standard voltage 24V/50-60Hz (±10%) 19VA
115V/50-60Hz (±10%) 19VA
230V/50-60Hz (±10%) 19VA
24VDC (± 10%) 18 Watt
DESCRIPTION VALVE EM25/EP25
1 Coil + Din Connector BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP25/EM
5 Remote operated cover TCOP25FM/EM
6 Diaphragm M25/EM/EP
6a Spring TMOL10G
7 Body TCOR25FMG
8 Conical seal G CON25
9 Retainer ring OG25
10 Compression nut TDAL25
11 O-ring G OR55x6
EP Integral solenoid pilot versionEM Remote pilot version
DESCRIPTION VALVE EM40/EP40
1 Coil + Din Connector BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP25
5 Remote operated cover TCOP25FM
6 Diaphragm M25
6a Spring TMOL10G
7 Screws + Washers VTE8x20+TROND8GROWER
8 Cover TCOP40N
9 Spring TMOL40
10 Main diaphragm M40
11 Body TCOR40FMG
12 Conical seal GCON40
13 Retainer ring OG40
14 Compression nut TDAL40
15 O-ring G OR64,3x5,7
EP Integral solenoid pilot versionEM Remote pilot version
Model Ø C A B Ø D F G I L M N Ø E Weight (Kg)
EP 25 1“ 60 82 9 82 74 119 106 217 81 1“1/2 1
EP 40 1“1/2 72 99 11 96 140 160 115 278 96 2” 2,3
EM 25 1“ 60 82 9 82 74 119 106 159 81 1“1/2 0,9
EM40 1“1/2 72 99 11 96 140 160 115 220 96 2” 2,1
51
FLANGED PULSE VALVES B3
Overall dimensions / D Series E
B4 GLOBAL PULSE VALVES FOR SQUARE TANK
SQ SQ Series - Ø 1”
52
CHARACTERISTICS
Fluid Filtered and oilfree compressed air
Temperature STD diaphragm -20°C; +80°Crange Viton diaphragm -20°C; +200°C
Operating pressure min 0,5 bar - max 7,5 bar
Body and cover Die cast aluminium
Core tube Stainless steel
Plunger Stainless steel
Screws Stainless steel
Coil insulation Class H
Din’s connector PG 9 EN175301-803
Protection Din’s connector + Coil IP65 EN60529
Standard voltage 24V/50-60Hz (±10%) 19VA
115V/50-60Hz (±10%) 19VA
230V/50-60Hz (±10%) 19VA
24VDC (± 10%) 18 Watt
DESCRIPTION VALVE SQM25/SQP25
1 Coil + Din Connector BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP25
5 Remote operated cover TCOP25FM
6 Diaphragm M25
6a Spring TMOL10G
7 Body TCOR25IM
8 O-ring G OR65x4
SQP Integral solenoid pilot version / SQM Remote pilot version
DESCRIPTION VALVE SQMO25/SQPO25
1 Coil + Din Connector BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP25
5 Remote operated cover TCOP25FM
6 Diaphragm M25
6a Spring TMOL10G
7 Screws VTCEI6x16
8 Body TCOR25IMO
9 O-ring G OR65x4
SQPO Integral solenoid pilot version / SQMO Remote pilot version
53
GLOBAL PULSE VALVES FOR SQUARE TANK B4
Overall dimensions / SQ Series SQ
Model Ø A Ø B Ø C Ø D Ø E Ø M F G H I L Weight (Kg)
SQPO 25 1“ 41,4 62,2 104 116 92 25 31,5 20,2 136 6,2 0,7
SQP 25 1“ 41,4 62,2 104 116 92 25 31,5 20,2 136 6,2 0,7
SQMO 25 1“ 41,4 62,2 104 116 92 25 31,5 20,2 78 6,2 0,5
SQM 25 1“ 41,4 62,2 104 116 92 25 31,5 20,2 78 6,2 0,5
B4 GLOBAL PULSE VALVES FOR SQUARE TANK
SQ SQ Series - Ø 1”1/2
54
CHARACTERISTICS
Fluid Filtered and oilfree compressed air
Temperature STD diaphragm -20°C; +80°Crange Viton diaphragm -20°C; +200°C
Operating pressure min 0,5 bar - max 7,5 bar
Body and cover Die cast aluminium
Core tube Stainless steel
Plunger Stainless steel
Screws Stainless steel
Coil insulation Class H
Din’s connector PG 9 EN175301-803
Protection Din’s connector + Coil IP65 EN60529
Standard voltage 24V/50-60Hz (±10%) 19VA
115V/50-60Hz (±10%) 19VA
230V/50-60Hz (±10%) 19VA
24VDC (± 10%) 18 Watt
DESCRIPTION VALVE SQM35/SQP35
1 Coil + Din Connector BH10...V/50-60Hz
2 Screws + Washers VTE6x18+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP10
5 Remote operated cover TCOP10FM
6 Spring TMOL10G
7 Diaphragm M10
8 Screws + Washers VTE6x20+TROND6GROWER
9 Cover TCOP35N
10 Spring TMOL25GHS
11 Diaphragm M35
12 Body TCOR35FMG
13 O-ring G OR6337
SQP Integral solenoid pilot versionSQM Remote pilot version
DESCRIPTION VALVE SQO35/SQPO35
1 Coil + Din Connector BH10...V/50-60Hz
2 Screws + Washers VTE6x18+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP10
5 Remote operated cover TCOP10FM
6 Spring TMOL10G
7 Diaphragm M10
8 Screws + Washers VTE6x20+TROND6GROWER
9 Cover TCOP35N
10 Spring TMOL25GHS
11 Diaphragm M35
12 Screws VTCEI8x20
13 Body TCOR35FMGS
14 O-ring G OR6337
SQPO Integral solenoid pilot versionSQMO Remote pilot version
55
GLOBAL PULSE VALVES FOR SQUARE TANK B4
Overall dimensions / SQ Series - Ø1”1/2 SQ
Model Ø A Ø B Ø C Ø D Ø E F G H M Weight (Kg)
SQP 35 1”1/2 57 80,5 114 9 42 26 162 130 1,6
SQPO 25 1”1/2 57 80,5 114 9 42 26 162 130 1,6
SQM 35 1”1/2 57 80,5 114 9 42 26 104 130 1,4
SQMO 35 1”1/2 57 80,5 114 9 42 26 104 130 1,4
B4 GLOBAL PULSE VALVES FOR SQUARE TANK
SQ SQ Series - Ø 2” - 2”1/2 - 3”- 4”
56
CHARACTERISTICS
Fluid Filtered and oilfree compressed air
Temperature STD diaphragm -20°C; +80°Crange Viton diaphragm -20°C; +200°C
Operating pressure min 0,5 bar - max 7,5 bar
Body and cover Die cast aluminium
Core tube Stainless steel
Plunger Stainless steel
Screws Stainless steel
Coil insulation Class H
Din’s connector PG 9 EN175301-803
Protection Din’s connector + Coil IP65 EN60529
Standard voltage 24V/50-60Hz (±10%) 19VA
115V/50-60Hz (±10%) 19VA
230V/50-60Hz (±10%) 19VA
24VDC (± 10%) 18 Watt
DESCRIPTION VALVE SQM50/SQP50
1 Coil + Din Connector BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP25
5 Remote operated cover TCOP25FM
6 Diaphragm M25
6a Spring TMOL10G
7 Screws + Washers VTE10x25+TROND10GROWER
8 Cover TCOP50G
9 Spring TMOL40
10 Diaphragm M50
11 Body TCOR50FG
12 O-ring G OR133,35x5,3
SQP Integral solenoid pilot versionSQM Remote pilot version
DESCRIPTION VALVE SQM75IN/SQP75IN
1 Coil + Din Connector BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP25
5 Remote operated cover TCOP25FM
6 Diaphragm M25
6a Spring TMOL10G
7 Screws + Washers VTE10x25+TROND10GROWER
8 Cover TCOP65G
9 Spring TMOL40
10 Diaphragm M76
11 Body TCOR75FLQ
12 O-ring G OR177,17x6,99
SQP Integral solenoid pilot versionSQM Remote pilot version
DESCRIPTION VALVE SQM100IN/SQP100IN
1 Coil + Din Connector BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP25
5 Remote operated cover TCOP25FM
6 Diaphragm M25/BW
6a Spring TMOL10G
7 Screws + Washers VTE10x25+TROND10GROWER
8 Cover TCOP65G
9 Spring TMOL40
10 Diaphragm M76
11 Body TCOR100FLQ
12 O-ring G OR177,17x6,99
SQP Integral solenoid pilot versionSQM Remote pilot version
DESCRIPTION VALVE SQM65IN/SQP65IN
1 Coil + Din Connector BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP25
5 Remote operated cover TCOP25FM
6 Diaphragm M25
6a Spring TMOL10G
7 Screws + Washers VTE10x25+TROND10GROWER
8 Cover TCOP65G
9 Spring TMOL40
10 Diaphragm M55/LP
11 Body TCOR65FLQ
12 O-ring G OR177,17x6,99
SQP Integral solenoid pilot versionSQM Remote pilot version
57
GLOBAL PULSE VALVES FOR SQUARE TANK B4
Overall dimensions / SQ Series - Ø2” -2”1/2 - 3”- 4” SQ
Model Ø A Ø B Ø C Ø D Ø E F G H I L Weight (Kg)
SQP 50 2“ 83 126 175 195 39 60 20 211 11 2,4
SQP 65IN 2”1/2 107,5 161 225 247 44 35,5 27 205 11 3,9
SQP 75IN 3“ 107,5 161 225 247 50 35,5 27 205 11 3,7
SQP 100IN 4“ 119,5 161 225 247 44 35,5 27 205 11 3,8
SQM 50 2“ 83 126 175 195 39 60 20 153 11 2,2
SQM 65IN 2”1/2 107,5 161 225 247 44 35,5 27 147 11 3,7
SQM 75IN 3“ 107,5 161 225 247 50 35,5 27 147 11 3,5
SQM 100IN 4“ 119,5 161 225 247 44 35,5 27 148 11 3,6
B5 STRAIGHT THROUGH PULSE VALVE
FD FD Series Ø1”
58
CHARACTERISTICS
Fluid Filtered and oilfree compressed air
Temperature STD diaphragm -20°C; +80°Crange Viton diaphragm -20°C; +200°C
Operating pressure min 0,5 bar - max 7,5 bar
Body and cover Die cast aluminium
Core tube Stainless steel
Plunger Stainless steel
Screws Stainless steel
Coil insulation Class H
Din’s connector PG 9 EN175301-803
Protection Din’s connector + Coil IP65 EN60529
Standard voltage 24V/50-60Hz (±10%) 19VA
115V/50-60Hz (±10%) 19VA
230V/50-60Hz (±10%) 19VA
24VDC (± 10%) 18 Watt
DESCRIPTION VALVE FDM25/FDP25
1 Coil + Din Connector BH10...V/50-60Hz
2 Screws + Washers VTE6x20+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP25
5 Remote operated cover TCOP25FM
6 Diaphragm M25
6a Spring TMOL10G
7 Body TCOR25FLG
8 Gasket TRON80x53x5
9 Lock nut TGBA25
10 Conical seal G CON25
11 Retainer ring OG25
12 Compression Nut TDAL25
FDP Integral solenoid pilot versionFDM Remote pilot version
59
GLOBAL PULSE VALVES FOR SQUARE TANK B5
Overall dimensions / FD Series - Ø1” FD
Model Ø A Ø B Ø C Ø D Ø E F G H Weight (Kg)
FDP25 1”1/4 1” 114 172 27 74 132 49,5 1,2
FDM25 1”1/4 1” 114 172 27 74 74 49,5 1
B5 STRAIGHT THROUGH PULSE VALVE
FD FD Series Ø1”1/2
60
CHARACTERISTICS
Fluid Filtered and oilfree compressed air
Temperature STD diaphragm -20°C; +80°Crange Viton diaphragm -20°C; +200°C
Operating pressure min 0,5 bar - max 7,5 bar
Body and cover Die cast aluminium
Core tube Stainless steel
Plunger Stainless steel
Screws Stainless steel
Coil insulation Class H
Din’s connector PG 9 EN175301-803
Protection Din’s connector + Coil IP65 EN60529
Standard voltage 24V/50-60Hz (±10%) 19VA
115V/50-60Hz (±10%) 19VA
230V/50-60Hz (±10%) 19VA
24VDC (± 10%) 18 Watt
DESCRIPTION VALVE FDM35/FDP35
1 Coil + Din Connector BH10...V/50-60Hz
2 Screws + Washers VTE6x18+TROND6GROWER
3 Pole assembly GPC10
4 Cover direct drive TCOP10
5 Remote operated cover TCOP10FM
6 Spring TMOL10G
7 Diaphragm M10
8 Screws + Washers VTE6x20+TROND6GROWER
9 Cover TCOP35N
10 Spring TMOL25GHS
11 Diaphragm M35
12 Body TCOR35FLG
13 Gasket TRON100x70x5
14 Lock nut TGBA40
15 Conical seal G CON40
16 Retainer ring OG40
17 Compression Nut TDAL40
FDP Integral solenoid pilot versionFDM Remote pilot version
61
GLOBAL PULSE VALVES FOR SQUARE TANK B5
Overall dimensions / FD Series - Ø1” 1/2 FD
Model Ø A Ø B C D E F G H Weight (Kg)
FDP35 2” 1”1/2 155 228 32 115 186 67,5 2,3
FDM35 2” 1”1/2 155 228 32 115 131 67,5 2,1
62
BULKHEAD CONNECTORS
C1 Bulkhead connector PS/PD Series
C2 Wrench SG/SD Series
63
C1 BULKHEAD CONNECTORS
PS/PD Series
DESCRIPTION PS20 PS25 PS40 PS50
1 Compression nut TDAL20/25 TDAL25 TDAL40 TDAL50
2 Retainer ring OG20 OG25 OG40 OG50
3 Conical seal G CON20 G CON25 G CON40 G CON50
4 Lock nut TGBA25 TGBA25 TGBA40 TGBA50
5 Gasket TFIBRA70x54x1,5 TFIBRA70x54x1,5 TFIBRA90x70x1,5 TRON115x88x5
6 Body TPAS20/LAV TPAS25/LAV TPAS40/LAV TPASS50/LAV
DESCRIPTION PD20 PD25 PD40 PD50
1 Compression nut TDAL20/25 TDAL25 TDAL40 TDAL50
2 Retainer ring OG20 OG25 OG40 OG50
3 Conical seal G CON20 G CON25 G CON40 G CON50
4 Lock nut TGBA25 TGBA25 TGBA40 TGBA50
5 Gasket TFIBRA70x54x1,5 TFIBRA70x54x1,5 TFIBRA90x70x1,5 TRON11x88x5
6 Body TPAS20 TPAS25 TPAS40 TPASS50
64
P Series Bulkhead connectors provide a simple and economic
solution to installation by eliminating the need for welding or
threaded pipe connections.
∑ • PD Seriesis a double ended connector for two-piece blow tube
• PS Series
is a single ended connector for one-piece blow tube
∑
PS/PD
BULKHEAD CONNECTORS C1
Overall dimensions / PS/PD Series PS/PD
TECHNICAL CHARACTERISTICS
Body, lock nut, compression nut Die cast aluminium
Seal NBR -30°C / +100°CSilicon -60°C / +200°C
ASSEMBLY HOLE 3/4” Wall hole ø min. 56
1” Wall hole ø min. 56
1”1/2 Wall hole ø min. 72
2” Wall hole ø min. 93
65
Model Ø A B C1 D E F Weight (Kg)
PS 20 3/4” 10,5 12,5 67 35 56 0,5
PS 25 1” 10,5 12,5 67 35 56 0,4
PS 40 1”1/2 15 16,5 92 40 79 0,8
PS 50 2” 15,5 29 98 42 83 1,6
Model Ø A B B1 C D E F Weight (Kg)
PD 20 3/4” 10,5 12,5 35 105 50 39 0,7
PD 25 1” 10,5 12,5 35 105 50 39 0,6
PD 40 1”1/2 15 16,5 40 140 67 55 1,2
PD 50 2” 15,5 29 42 150 - - 2,2
C2 WRENCH
SG/SD Series
WRENCH SD FOR COMPRESSION NUT
Model Ø A H L
SD20 3/4” 61 70 350
SD25 1” 61 70 350
SD40 1”1/2 82 85 430
SD50 2” 110 100 430
WRENCH SG FOR LOCK NUT
Model Ø A H L
SG20 3/4” 70 65 350
SG25 1” 70 65 350
SG40 1”1/2 90 85 430
SG50 2” 120 100 430
66
SG/SD
Remote Solenoid EnclosuresD1 RCP Series
D2 RLD Series
D3 TRCP Series
67
REMOTE SOLENOID ENCLOSURES
RCP : PILOT VALVE BOX IP 66
RLD : PILOT VALVE BOX IP 66
TRCP : PILOT VALVE BOX IP 66
Heating thermostat (option)
Power 70W for RCP5
Power 120W for RCP8 and RCP12
NUMBER OF PILOT VALVES
RCP 1-2-3-4-5 (Enclosure small)
RCP 6-7-8 (Enclosure medium)
RCP 9-10-11-12 (Enclosure large)
TRCP 1-2-3-4-5-6-7-8 (Enclosure medium)
RCP 5 V/... Rexample
D REMOTE SOLENOID ENCLOSURES
D HOW THE ORDER
Code RCP5V/...R is for a remote solenoidenclosures IP 66 (RCP) with five pilotsmounted electrical (5), power supply 24V50Hz (V/...), with heating thermostat (R).
Turbo offer a range of pilot valve boxes for outdoor applications and hazardous locations.
Model available:
∑ • RCP maximum lenght of pilot tubes 3m
∑ • RLD maximum lenght of pilot tubes 10m
Tubes 6 or 8 mm should be used for pneumatic connections to the pulse valves.
Remote solenoid enclosures RCP and RLD are supplied with pre-wired electric common terminals.
TRCP remote solenoid enclosures have all coils electrical complete cabled on the printed circuit inside the enclosure.
Thermostat with heater is reccomemded to prevent moisture or freezing inside of remote solenoid enclosures.
This system ensures a minimum temperature of 5°C inside the enclosure.
REMOTE SOLENOID ENCLOSURES ACCORDING TO ATEX II 3D T100°C
IP66 NEMA 4 UL50
68
RCP
SAMPLE INSTALLATION
VOLTAGE
24V/50-60Hz =02450
115V/50-60Hz =11050
230V/50-60Hz =22050
24VDC =024DC
(TRCP = 024DC - 5W)
REMOTE SOLENOID ENCLOSURES D1
RCP Series RCP
69
CHARACTERISTICS
Fluid Filtered and oilfree compressed air
Operating pressure min 0,5 bar - max 7,5 bar
Temperature range -20°C +80°C
W/Heating -40°C +80°C
Base and cover Die cast aluminium
Core tube Stainless steel
Plunger Stainless steel
Screws Stainless steel
Coil insulation Class H
Protection IP66
Standard voltages 230 -110 - 24V
50-60VHz 19 VA24VDC 15W
Model A B C D E Ø M Ø N Weight (Kg)
RCP5 210 98 10 156 100 1/8“ 11 1,7
RCP8 333 98 10 267 100 1/8“ 11 3,2
RCP12 306 97 10 237 152 1/8“ 11 4,4
RCP5
RCP8
RCP12
(*) Minimum distance to allow the opening of the cover
D2 REMOTE SOLENOID ENCLOSURES
RLD RLD Series
RLD5
RLD8
RLD12
Model A B C D E Ø M Ø N Weight (Kg)
RLD5 210 98 10 156 100 1/8“ 11 1,7
RLD8 333 98 10 267 100 1/8“ 11 3,2
RLD12 306 97 10 237 152 1/8“ 11 4,4
CHARACTERISTICS
Fluid Filtered and oilfree compressed air
Operating pressure min 0,5 bar - max 7,5 bar
Temperature range -20°C +80°C
W/Heating -40°C +80°C
Base and cover Die cast aluminium
Core tube Stainless steel
Plunger Stainless steel
Screws Stainless steel
Coil insulation Class H
Protection IP66
Standard voltages 230 -110 - 24V
50-60VHz 19 VA24VDC 15W
70
(*) Minimum distance to allow the opening of the cover
REMOTE SOLENOID ENCLOSURES D3
TRCP Series TRCP
CHARACTERISTICS
Fluid Filtered and oilfree compressed air
Operating pressure min 0,5 bar - max 7,5 bar
Temperature range -20°C +80°C
Base and cover Die cast aluminium
Core tube Stainless steel
Plunger Stainless steel
Screws Stainless steel
Coil insulation Class H
Protection IP66
Standard voltages 24VDC (5W)
Model A B C D E Ø M Ø N Weight (Kg)
TRCP8 333 136,5 10 267 100 1/8“ 11 3,3
71
(*) Minimum distance to allow the opening of the cover
72
Remote PilotsE1 SR Series
TSRM Series
E2 LD Series
REMOTE PILOTS
73
SRC : PILOT VALVE WITH CONNECTOR
SRM : PILOT VALVE SCREWS TERMINAL
TSRM: PILOT VALVE WITH FASTON CONNECTION
LDC : PILOT VALVE WITH CONNECTOR
LDM : PILOT VALVE SCREWS TERMINAL
SRM 02450example
Code SRM02450 is for pilot valve with screws terminal (SRM) power supply 24V 50Hz (02450).
REMOTE PILOT VALVE
Designed for panel mounting or Turbo boxes. Two models are available:
∑ • Series SR/TSRM, max. lenght of pilot tubes 3m
∑ • Series LD, max. lenght of pilot tubes 10m
Two ways normally closed. Tubes 6 or 8 mm. diameter should be used for pneumatic connections to the pulse valves.
74
E REMOTE PILOTS
HOW TO ORDER
VOLTAGE
24V/50-60Hz =02450115V/50-60Hz =11050230V/50-60Hz =2205024VDC =024DC
(TSRM = 024DC - 5W9)
75
CHARACTERISTICS
Fluid Filtered and oilfree compressed air
Operating pressure min 0,5 bar - max 7,5 bar
Temperature range -20°C +80°C
Body Brass
Core tube Stainless steel
Plunger Stainless steel
Coil insulation Class H
Connector PG9 / IP 65
Standard voltages 230 -110 - 24V/50-60VHz (19 VA)
24VDC (15W) - 24VDC (5W)
15WATT
24V DC
15WATT
24V DC
3 mt max
SRC - IP65
SAMPLE INSTALLATION
REMOTE PILOTS E1
SR/TSRM Series SR/TSRM
Available with ATEX coil zone 21 and zone 22
SRM - IP00
E1 REMOTE PILOTS
SR/TSRM Series
76
SR/TSRM
Description SRC
1 Body PCRP
2 Lock nut +O-ring TGHIERA 18x1 + G OR3081
3 Pole assembly GPC10
4 Coil + Din Connector BH10
Description SRM
1 Body PCRP
2 Lock nut +O-ring TGHIERA 18x1 + G OR3081
3 Pole assembly GPC10/R
4 Coil BH10.../.. - A9
Description TSRM
1 Body PCRP
2 Lock nut +O-ring TGHIERA 18x1 + G OR3081
3 Pole assembly GPC10/R
4 Coil BH10 024/DC/5W - A9
5 Quick fitting forrilsan tube 6x4 TGOMINNRAP
SRC SRM
TSRM
77
REMOTE PILOTS E2
Remote pilots for long distance/LD Series LD
15WATT
24V DC
C
15WATT
C24V DC
10 mt max
LDC
LDM
SAMPLE INSTALLATION
CHARACTERISTICS
Fluid Filtered and oilfree compressed air
Operating pressure min 0,5 bar - max 7,5 bar
Temperature range -20°C +80°C
Body Brass
Core tube Stainless steel
Plunger Stainless steel
Coil insulation Class H
Connector PG9 / IP 65
Standard voltages 230 -110 - 24V/50-60VHz (19 VA)
24VDC (15W)
Available with ATEX coil zone 21 and zone 22
LDC
E2 REMOTE PILOTS
LD Remote pilots for long distance/LD Series
DESCRIPTION LDC
1 Body PCRPLD
2 Lock nut + O-ring TGHIERA18x1+G OR3081
3 Pole assembly GPC10
4 Coil + Din connector BH10.../..
DESCRIPTION LDM
1 Body PCRPLD
2 Lock nut + O-ring TGHIERA18x1+G OR3081
3 Pole assembly GPC10/R
4 Coil BH10.../.. - A9
LDM
78
79
ATEX II3GD (zone 2 and 22)
ATEX II2GD (zone 1 and 21)
Turbo pulse valves for potentially explosive
atmospheres according to ATEX 94/9/EC
valve is provided with molded coil and con-
nector IP 65.
Valve dimensions are same of standard
model.
Turbo pulse valves for potentially explosive atmospheres
according to ATEX 94/9/EC.
Valve use encapsulated molded coil with leads wire of dif-
ferent lenght.
Pilot valve has brass body that change valve dimensions
from standard model.
ATEX PULSE VALVES
ATEX
94-9-CE ATEX DIRECTIVE
ATEX
80
The European Community 94/9/EC Directive establishes the constructional and functional requirements(mandatory since 01/07/2003) for equipment and protection systems intended for use in potentially explo-sive atmosphere.
The Directive considers explosion hazard due to each source of ignition (electrical and not electrical), and themain important aspects introduced are:- Essential Health and Safety Requirements (Annex II-ESR)- Applicability both to materials used for underground mining (group I) and for those used in surface (Group II)- Classification of equipment in “categories” according to required protection level- Production surveillance based on Quality Management Systems
Directive 94/9/EC considers for the first time the explosion hazard due to a non-electrical source of ignition,such as mechanical sparks caused by vibrations or impact, high surface temperature of mechanical and electri-cal components caused by non-electrical sources such as vibrations, high rotating speed, etc.Furthermore the Directive establishes to carefully evaluate the environment of installation of the equipment, itsstorage and functioning, in order to classify it according to a possible presence of explosive atmosphere.The Directive, in fact, through the Essential Health and Safety Requirements considers that equipment them-selves can be a source of explosive atmosphere and provides for requirements in order to prevent such risks (AnnexII point 1.0.1.)
Aim of the European Directive. Directive 94/9/EC (ATEX) was adopted by the European Community to ensurefree movement of products intended for use in potentially explosive atmospheres. It provides for harmonized tech-nical requirements and applicable standards.This Directive aims to preserve people’s health and goods from risks coming from the use of equipment and pro-tection systems in a "potentially explosive atmosphere.
Explosive atmosphere is a mixture with air, under specific atmospheric conditions (temperature from -20°C to+40°C and pressure from 0,8 bar to 1,1 bar according to EN60079 and EN13463-1), of flammable substancesin the form of gases, vapors, mists or dusts in which, after ignition has occurred, combustion spreads to the entireunburned mixture (see also Directive 94/9/EC Cap. I art. 1)
Potentially explosive atmosphere is an atmosphere that could become explosive due to local operating con-ditions
Hazardous explosive areas according to Directive 1992/92/CE. Areas where hazardous explosive atmos-pheres may occur are classified into zones based on their likelihood and persistence.
Zone 0
Area in which an hazardous explosive atmosphere consisting of a mixture with air of dangerous substances inthe form of gas, vapor or mist is present continuously or for long periods or frequently.Zone 1
Area in which an hazardous explosive atmosphere consisting of a mixture with air of dangerous substances inthe form of gas, vapor or mist is likely to occur in normal operation occasionallyZone 2Area in which an hazardous explosive atmosphere consisting of a mixture with air of dangerous substances inthe form of gas, vapor or mist is not likely to occur in normal operation but, if it does occur, will persist for ashort period only.
NOTE
82
SEQUENCERSECONOMISERS
CONTROL UNITS WITHREMOTE PILOTS
MATRIXWIRING SYSTEM
TURBONETBUS SYSTEM
EMISSION MONITORING SYSTEMS AND TRIBO-CHECK PROBES
ATEX CERTIFIED
(zone 1,2,21 & 22)
LA
ELECTRONIC SYSTEMS
PRODUCT OVERVIEW
83
Electronic controlSystems
DUST FILTER COMPONETS
ELECTRONIC SYSTEMS
B
E 4 - 8 - 12 -16
NUMBER OF OUTPUTS
U=24Vcc B=24V 50-60Hz L=115V 50-60Hz
M=230V 50-60Hz
MULTIPLE OUTPUT VOLTAGE
U=24Vcc B=24V 50-60Hz L=115V 50-60HzM=230V 50-60Hz
STANDARD MULTIPLE SUPPLY VOLTAGE
E 16example ECONOMISER E SERIES
ECONOMISERS AND SEQUENCERS
HOW TO ORDER
E16 MB is a 16-way E economiser
with 230VAC supply voltage and 24VAC output voltage
M
BM
BA 4 - 8 - 12 -16
NUMBER OF OUTPUTS
U=24Vcc B=24V 50-60HZ L=115V 50-60HZM=230V 50-60Hz
MULTIPLE OUTPUT VOLTAGE
M=230V 50-60Hz L=115V 50-60 Hz
STANDARD SUPPLY VOLTAGE
U=24Vcc B=24V 50-60Hz
OPTIONAL SUPPLY VOLTAGE
M=230V 50-60Hz L=115V 50-60Hz
STANDARD SUPPLY VOLTAGE
U=24Vcc B=24V 50-60Hz
OPTIONAL SUPPLY VOLTAGE
BA 16example ECONOMISER BA SERIES
BA16 MB is a 16-way BA economiser
with 230VAC supply voltage and 24VAC output voltage
S16 MB is a 16-way S sequencer
with 230VAC supply voltage and 24VAC output voltage
BM
S 4 - 8 - 12 -16
NUMBER OF OUTPUTS
U=24Vcc B=24V 50-60HZ L=115V 50-60HZM=230V 50-60Hz
MULTIPLE OUTPUT VOLTAGE
U=24Vcc B=24V 50-60Hz L=115V 50-60HzM=230V 50-60Hz
STANDARD MULTIPLE SUPPLY VOLTAGE
U=24Vcc B=24V 50-60HZ L=115V 50-60HZM=230V 50-60HZ
MULTIPLE OUTPUT VOLTAGE
S 16example SEQUENCER S SERIES
PA 4 - 8 - 12 -16
NUMBER OF OUTPUTS
PA 16example SEQUENCER PA SERIES
PA16MB is a16-way sequencer
with 230VAC supply voltage and 24VAC output voltage
BM
Dust Filters Components
Economiser with digital E Series
∆P control
Economiser with digital BA Series
∆P control
Cyclic sequencer S Series
Cyclic sequencer PA Series
Digital ∆P controller BPB Series
Electronic single timer TCONTEMP
TURBONET TURBO-NET 144
Bus system
MATRIX MTX
Wiring system
Dust emission probe TC Series
Dust emission probe controller DTC Series
PRODUCT INDEX
DEVICE PERFORMANCES
LCD Display with backlight and friendly menus in six languages
Three modes of operation: manual, auto and full-auto mode to smart filter mana-
gement
Operating time in seconds and minutes with selectable range for any applications
Four units selectable for differential pressure measures
No selection jumpers required for the output voltages of the valves that is done
automatically according to the positioning of the common of pulse valves in the
terminal
Multi-selectable power supply thought just one jumper located in the terminals
compartment
Post-cleaning function with selectable number of cycles up to 255 cycles
Hours counter and pulses counter
Up two programmable alarm relays
Minimum differential pressure
Maximum differential pressure
Maximum current pulse valves dissipation
Pulse Valves not working alarm
Power down
External input to start/stop cleaning from remote
External input to start/stop cleaning from air tank sensor
Automatic precoating functions
4-20mA output to remote dP pressure
Zero crossing switching pulse valve
Pulse valves manual activation
Selection of pulse-jet cleaning systems or rotating nozzle with self-selection of opti-
mal parameters
Protection from current overload for device and pulse valves
Description
The control instruments “E” series eco-
nomizer are among the most modern
and complete available today on the
market.
They have been built to command
membrane solenoids on dust removal
filters. A large back lighted liquid
crystal display clearly shows the filter
and the cleaning system status. It has
a fast-flow setting menu with intuiti-
ve operation that allows the operator
to choose one of five different lan-
guages offered, and to select from
four different pressure-reading scales
(mbar, kpa “H2O and mmH2O). The clog-
ging level can be seen on a numerical
and/or graphic scale. The pre-coating
deactivation function, the recognition
of the valves connected and the post-
washing function are all completely auto-
matic.
What makes this “E” Series totally inno-
vative is the software installed in the
powerful microprocessor, which directs
the full-automatic operation. This mode
makes the instrument completely auto-
nomous and independent in the mana-
gement of the filter washing, modula-
ting the pause and shooting time
depending on the clogging level. The
”cleaning”, then, is increased or redu-
ced automatically depending on the real
needs; this optimizes the economy of
the entire system.
ECONOMISER FOR DEDUSTING PLANTS
WITH DIGITAL ∆P CONTROL BY INTERNAL TRANSDUCER
E SeriesE
VALVES
Terminal signal Terminal signal
1 EV1 Solenoid valve 1 9 EV9 Solenoid valve 9
2 EV2 Solenoid valve 2 10 EV10 Solenoid valve 10
3 EV3 Solenoid valve 3 11 EV11 Solenoid valve 11
4 EV4 Solenoid valve 4 12 EV12 Solenoid valve 12
5 EV5 Solenoid valve 5 13 EV13 Solenoid valve 13
6 EV6 Solenoid valve 6 14 EV14 Solenoid valve 14
7 EV7 Solenoid valve 7 15 EV15 Solenoid valve 15
8 EV8 Solenoid valve 8 16 EV16 Solenoid valve 16
The common of solenoid valves must be connected to the type of pilot according
to the following table:
Terminal LEGEND Voltages
17 230V 230VAC 50Hz
18 115V 115VAC 50Hz
19 24DC 24VDC
20 24AC 24VAC 50Hz
NOTE: THE TERMINAL 31 IS THE GROUND OF DEVICE AND PULSE VALVES
POWER
Power Supply 230-115-24/50hz
Terminal 30 L phase
Terminal 33 N Neutral
Terminal 31 PE Ground
Power Supply 24 VDC
Terminal 32 DC +
Terminal 25 GND Negative
Terminal 31 PE ground
(internally connect to 25)
ECONOMISER FOR DEDUSTING PLANTS
WITH DIGITAL ∆P CONTROL BY INTERNAL TRANSDUCER
E Series
CONNECTION LAYOUT
CE DIRECTIVES
This product is compliant with the follo-wing directives:
Machine Direct ive 2006/42/EC‘Electromagnetic compatibility’ related tothe European Standard EN61000-6-2:2005class B of the rule EN61000-6-4:2001. LowVoltage Directive 2006/95/CE related tothe European Standard EN60947-1:2004
E
ELECTRICAL CHARACTERISTICS
Power
230VAC ±10% 50 Hz
115VAC ±10% 50 Hz
24VAC ±10% 50 Hz
24VDC ±10%
Output
24VAC (MAX 20VA @ Ton Max 5s)
24VDC (MAX 20W@ Ton Max 5s)
230VAC (MAX 20VA@ Ton=10s)
115VAC (MAX 20VA@ Ton=10s)
Fuses
1 x 2 Ampere
Working temperature
-15°C÷50°C
Storage temperature
-20°C÷60°C
Timing
Pause time
5 s ÷ 50 min
Working time (air pulse)
50 ms ÷ 10 s (step 10 ms)
Differential pressure Meter
Range: 0 ÷ 10 KPa
Maximum differential pressure:
50 kPa – 0.5 bar
TECHNICAL CHARACTERISTICS
Standard supply voltage 230 VAC / 115 VAC
Supply voltage available upon request 24 VAC / 24 VDC
Output voltage 230/115 / 24VAC - 24VDC
Working temperature range -10°C ÷ +50°C
Absorbed power 10 VA (Stand by)
Protection level IP65
Max no. of outputs 16
Dimensions 140x230x95 (BA4 - BA16)
Material ABS / RAL 7035
STANDARD FEATURES
Manual selection of output number / solenoid valve
Adjustable activation time per each output from 0.05 to 5 sec.
Adjustable interval time between two activations from 1 to 999 sec.
Short circuit output protection
Manual activation of each single output
Digital differential pressure control
Differential pressure reading by internal transducer (max 10kPa)
Maximum dP alarm with alarmed contact open and automatic reset
Zero dP reading adjustment
10kPa dP reading full range
Additional post-cleaning cycle after fan stop
Cleaning cycle ON/OFF by volt free external contact
Max 25W load power per each output
Input and output selection by JP1, JP2 and JP3 jumpers on the board
DESCRIPTION
Economiser for dedusting plant cleaning cycle with digital ∆P
control.
Microprocessor-operated device with electrical zero connected to
ground which ensures high immunity to external interfe-
rence and low field emissions.
Max 1 output relay. Max 2 volt free digital inputs.
BA4 to control 4 solenoid valves
BA8 to control 8 solenoid valves
BA12 to control 12 solenoid valves
BA16 to control 16 solenoid valves
ECONOMISER FOR DEDUSTING PLANTS
WITH DIGITAL ∆P CONTROL BY INTERNAL TRANSDUCER
BA4 /BA8 / BA12 /BA16 Series - Multiple output voltageUp to 144 outputs available upon request with different enclosures BA
Connect by rylsan tube 4/6
PARAMETER SETTING IN SET MODE
In Run Mode press key C to enter the function menu
F01 Digital input use 0 = included 1 = excluded
F02 Pulse time 0,05 ÷ 5,00 sec
F03 Time interval between events 1 ÷ 999 sec (see B3x)
F04 Number of outputs 0 ÷ 16
F05 Cycles after fan stop 0 ÷ 99
F06 Manual activation C = Selection A = Output activation
F07 ∆P control 0 = excluded 1 = includedo
F08 Output voltage 24V, 115V, 230V (see HV)
F09 Zero ∆P adjustment 0,00 (see C8)
F10 ∆P threshold for cycle STOP 0,01 ÷ 9,99 kPa
F11 ∆P threshold for cycle START 0,01 ÷ 9,99 kPa
F12 Max ∆P alarm threshold 0,01 ÷ 9,99 kPa
F13 Fan mode selection 0 = by contact 1= by ∆P reading
Key A = Access to the selected function Key A = Parameter decrement in
Key B = Exit from Set Up Key B = Return to function menu
Key C = Function selection Key C = Parameter increase in Set
OPERATION
When power is supplied, the cleaning cycle starts if all the conditions requiredfor operation are present
OFF Cycle stopped due to cleaning consent missing (D6 open)
- 0 - Cycle stopped due to fan OFF
‘P’ Cycle stopped due to low dP (Blinking display)
A01 No. of activated EV
... Cycles active after fan stop (Blinking points)
--- Bar indicating pause time flow between events
E ∆P reading over 9.99kPa
Key B Alarm Reset
Key C Access to Set Up
ALARM DESCRIPTION
3,00/H = Maximum ∆P alarm
(Blinking display)
example: E1/05 = 05 output overload
(Blinking display)
NOTE
The device will automatically switch from
Set Mode to Run Mode if no key is pres-
sed for 5 minutes
ECONOMISER FOR DEDUSTING PLANTS
WITH DIGITAL ∆P CONTROL BY INTERNAL TRANSDUCER
BA4 /BA8 / BA12 /BA16 Series - Multiple output voltageUp to 144 outputs available upon request with different enclosures
2 31
SUPPLY VOLTAGE
FUSE
(See Table 1)
NOTE DC: With 24VDC supply voltage, the available output voltage decreases by 2V for internal timer voltage drop. Check the compatibility with the solenoid valves used.
Do no connect any supply voltage pole to ground with 24VDC supply voltage.
4 5CUMULATIVE FAULT/ ALARM RELAY
Contact close with supply voltage ON and no alarm
BA
K15A/250V
14
15
D6
+P1 dP filter dirty side
-P2 dP filter clean side
dP10kPamax.
CLEANING CYCLE ON/OFF BY D6 EXTERNAL CONTACT
(Contact close = cycle active)
NOTE D6: put a wire at the clamps if not used with digital input enabled
D1a
12
13
FAN FAN SWITCH
(Contact close = fan ON)
NOTE D1a: put a wire at the clamps if not used with digital input enabled
COMMONOUTPUT No.
GROUND
EV1
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
3 30
EV3 EV5 EV7 EV9 EV11 EV13 EV15
EV2 EV4 EV6 EV7 EV10 EV12 EV14 EV16
SOLENOID VALVE VOLTAGE (see the label on the device)
Absorbed power 10 VA (Stand-by) + power EV.
Terminal 2,5 mm 250 VAC/12A
-10°C ÷ +50°CWorking
temperature
range
WIRING DIAGRAM
CE DIRECTIVES
This product is compliant with the follo-wing directives:
Machine Direct ive 2006/42/EC‘Electromagnetic compatibility’ related tothe European Standard EN61000-6-2:2005class B of the rule EN61000-6-4:2001. LowVoltage Directive 2006/95/CE related to theEuropean Standard EN60947-1:2004.
BA
DEVICE PERFORMANCES
LCD Display with backlight and friendly menu in six languages
Operating time in seconds and minutes with selectable range for any application
No selection jumpers required for the voltages of the valve
Multi-selectable power supply without removing the panel or the card from
enclosures
Post-cleaning function with selectable number of cycles up to 255 cycles
Hours counter and pulses counter
Up two programmable alarm relays
Pilot not working alarm
Power down
External input to start/stop cleaning from remote
External input to start/stop cleaning from air tank sensor
Zero crossing switching pilot valves
Pilot manual activation
Selection of pulse-jet cleaning systems or rotating nozzle with self-selection of
optimal parameters
Protection from current overload for device and pilot valves
Description
These control instruments series “S”
are among the most modern and com-
plete available today on the market.
They have been built to command
membrane solenoids on dust removal
filters. A large back lighted liquid
crystal display clearly shows cleaning
system status. It has a fast-flow setting
menu with intuitive operation that
allows the operator to choose one of
six different languages offered. The
recognition of the valves connected
and the post-washing function are all
automatic.
What makes this “S” Series totally inno-
vative is the software installed in the
powerful microprocessor, which directs
the full-automatic operation.
SEQUENCER FOR DEDUSTING PLANTS
S SeriesS
VALVES
Terminal signal Terminal signal
1 EV1 Solenoid valve 1 9 EV9 Solenoid valve 9
2 EV2 Solenoid valve 2 10 EV10 Solenoid valve 10
3 EV3 Solenoid valve 3 11 EV11 Solenoid valve 11
4 EV4 Solenoid valve 4 12 EV12 Solenoid valve 12
5 EV5 Solenoid valve 5 13 EV13 Solenoid valve 13
6 EV6 Solenoid valve 6 14 EV14 Solenoid valve 14
7 EV7 Solenoid valve 7 15 EV15 Solenoid valve 15
8 EV8 Solenoid valve 8 16 EV16 Solenoid valve 16
The common of solenoid valves must be connected to the type of pilot according
to the following table:
Terminal LEGEND Voltages
17 230V 230VAC 50Hz
18 115V 115VAC 50Hz
19 24DC 24VDC
20 24AC 24VAC 50Hz
NOTE: THE TERMINAL 31 IS THE GROUND OF DEVICE AND PULSE VALVES
POWER
Power Supply 230-115-24/50hz
Terminal 30 L phase
Terminal 33 N Neutral
Terminal 31 PE Ground
Power Supply 24 VDC
Terminal 32 DC +
Terminal 25 GND Negative
Terminal 31 PE ground
(internally connect to 25)
SEQUENCER FOR DEDUSTING PLANTS
S Series
CONNECTION LAYOUT
CE DIRECTIVES
This product is compliant with the follo-wing directives:
Machine Direct ive 2006/42/EC‘Electromagnetic compatibility’ related tothe European Standard EN61000-6-2:2005class B of the rule EN61000-6-4:2001. LowVoltage Directive 2006/95/CE related tothe European Standard EN60947-1:2004
S
ELECTRICAL CHARACTERISTICS
Power
230VAC ±10% 50 Hz
115VAC ±10% 50 Hz
24VAC ±10% 50 Hz
24VDC ±10%
Output
24VAC (MAX 20VA @ Ton Max 5s)
24VDC (MAX 20W@ Ton Max 5s)
230VAC (MAX 20VA@ Ton=10s)
115VAC (MAX 20VA@ Ton=10s)
Fuses
1 x 2 Ampere
Working temperature
-15°C÷50°C
Storage temperature
-20°C÷60°C
Timing
Pause time
5 s ÷ 50 min
Working time (air pulse)
50 ms ÷ 10 s (step 10 ms)
TECHNICAL CHARACTERISTICS
Standard supply voltage 230 VAC / 115 VAC
Supply voltage available upon request 24 VAC / 24 VDC
Output voltage 230/115 / 24VAC - 24VDC
Working temperature range -10°C ÷ +50°C
Absorbed power 10 VA (Stand by)
Protection level IP65
Max no. of outputs 16
Dimensions 140x170x95 (PA4 - PA8)
Dimensions 140x230x95 (PA12 - PA16)
Material ABS / RAL 7035
STANDARD FEATURES
Manual selection of output number / Autoselection
Adjustable activation time per each output from 0.05 to 5 sec.
Adjustable interval time between two activations from 1 to 999 sec.
Short circuit output protection
Manual activation of each single output
Cleaning cycle ON/OFF with external pressure controller by volt free contact
Additional post-cleaning cycle after fan stop
Cleaning cycle ON/OFF by volt free external contact
Max 25W load power per each output
Input and output selection by JP1, JP2 and JP3 jumpers on the board
DESCRIPTION
Sequencer for dedusting plant cleaning cycle. Microprocessor-ope-
rated device with electrical zero connected to ground which ensu-
res high immunity to external interference and low field
emissions.
Max 1 output relay. Max 2 volt free digital inputs.
PA4 to control 4 solenoid valves
PA8 to control 8 solenoid valves
PA12 to control 12 solenoid valves
PA16 to control 16 solenoid valves
SEQUENCER FOR DEDUSTING PLANTS
PA4 /PA8 / PA12 /PA16 Series - Multiple output voltageUp to 144 outputs available upon request with different enclosuresPA
PARAMETER SETTING IN SET MODE
In Run Mode press key C to enter the function menu
F01 Digital input use 0 = included 1 = excluded
F02 Pulse time 0,05 ÷ 5,00 sec
F03 Interval time between events 1 ÷ 999 sec (see B3x)
F04 Number of outputs 0 ÷ 16 (seeB1b)
F05 Cycles after fan stop 0 ÷ 99
F06 Manual activation C = Selection/ A = output activation
F07 Digital input 0 = C6, 1=D6 (see C6, D6)
F08 Output voltage 24V, 115V, 230V (see HV)
Key A = Access to the selected function Key A = Parameter decrement in Set
Key B = Exit from Set Up Key B = Return to function menu
Key C = Function selection Key C = Parameter increase in Set
OPERATION
When power is supplied, the cleaning cycle starts if all the conditions requiredfor operation are present
OFF Cycle stopped due to cleaning consent missing (D6 open)
- 0 - Cycle stopped due to fan OFF
1,00/P Cycle stopped due to low dP (Blinking display)
A01 No. of activated EV
... Cycles active after fan stop (Blinking points)
1,23 ∆P reading (kPa)
E ∆P reading over 9.99kPa
Key B Alarm Rest
Key C Access to Set Up
ALARM DESCRIPTION
3,00/H= Maximum ∆P alarm
(Blinking display)
example: E1/05 = : E1/05=05 output
overload
(Blinking display)
NOTE
The device will automatically switch from
Set Mode to Run Mode if no key is pressed
for 5 minutes
SEQUENCER FOR DEDUSTING PLANTS
PA4 /PA8 / PA12 /PA16 Series - Multiple output voltageUp to 144 outputs available upon request with different enclosures
2 31 4 5PA
K15A/250V
FUSE
(See Table 1)
COMMONOUTPUT No.
GROUND
14
15
(see set F07)C6/D6
SUPPLY VOLTAGE
CUMULATIVE FAULT/ ALARM RELAY
Contact close with supply voltage ON and no alarm
CLEANING CYCLE ON/OFF BY D6 EXTERNAL CONTACT
(Contact close = cycle active)
NOTE C6/D6: put a wire at the clamps if not used with digital input enabled
FAN FAN SWITCH
(Contact close = fan ON)
NOTE D1a: put a wire at the clamps if not used with digital input enabled
NOTE DC: With 24VDC supply voltage, the available output voltage decreases by 2V for internal timer voltage drop. Check the compatibility with the solenoid valves used.
Do no connect any supply voltage pole to ground with 24VDC supply voltage.
SOLENOID VALVE VOLTAGE (see the label on the device)
D1a
12
13
EV1
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
3 30
EV3 EV5 EV7 EV9 EV11 EV13 EV15
EV2 EV4 EV6 EV7 EV10 EV12 EV14 EV16
10 VA (Stand-by) + power EV.
2,5 mm 250 VAC/12A2
-10°C ÷ +50°C
Absorbed power
Terminal
Working
temperature
range
WIRING DIAGRAM
CE DIRECTIVES
This product is compliant with the follo-wing directives:
Machine Direct ive 2006/42/EC‘Electromagnetic compatibility’ related tothe European Standard EN61000-6-2:2005class B of the rule EN61000-6-4:2001. LowVoltage Directive 2006/95/CE related to theEuropean Standard EN60947-1:2004.
PA
TECHNICAL CHARACTERISTICS
Standard supply voltage 230 VAC / 115 VAC
Supply voltage available upon request 24 VAC / 24 VDC
Operating temperature range -10°C ÷ +50°C
Absorbed power 5 VA
Protection level IP65
Dimensions (mm) 180x130x75
PARAMETER SETTING IN SET MODE
In Run Mode press key C to enter the function menu
F01 Zero ∆P adjustment 0,00 (see C8)
F02 Min. ∆P alarm threshold 0,01 ÷ 9,99 kPa (E=disabled)
F03 Max ∆P alarm threshold 0,01 ÷ 9,99 kPa
Key A = Access to the selected function Key A = Parameter decrement in Set
Key B = Exit from Set Up Key B = Return to function menu
Key C = Function selection Key C = Parameter increase in Set
OPERATION
When power is supplied, dP control starts immediately
1,23 ∆P reading (kPa)
E ∆P reading over 9.99kPa
Key B Alarm reset
Key C Access to Set Up
ALARM DESCRIPTION
3,00/H Max dP alarm
(Blinking display)
0,50/L Min ∆P alarm
(Blinking display)
NOTE: The device will automatically switch from Set Mode to Run Mode if no key is
pressed for 5 minutes
STANDARD FEATURES
Minimum (K2) and maximum (K1) ∆P alarms on separate relays
Differential pressure reading by internal transducer (max 10kPa)
Minimum ∆P alarm with alarmed contact open and automatic reset
Maximum ∆P alarm with alarmed contact open and automatic reset
Zero ∆P reading adjustment
DESCRIPTION
Digital differential pressure controller between two points with
microprocessor.
Maximum 2 output relays.
DIGITAL DIFFERENTIAL PRESSURE CONTROLLER BY INTERNAL TRANSDUCER
BPB Series
BPB
2
10 VA (Stand-by) + power EV
2,5 mm 250 VAC/12A
-10°C ÷ +50°C
Absorbed power
Terminal
Working
temperature
range
FUSE250V / 500 mA (5x20)
+P1 9P filter dirty side
+P2 9P filter clean side
SUPPLY VOLTAGE
(see the label on the device)
MAX 9 P ALARM RELAY(Contact close with supply voltage ON and no alarm)
MIN 9 P ALARM RELAY(Contact close with supply voltage ON and no alarm)
4-20 mA 9 P reading(0.00 kPa+C13 x = 4+20 mA)
Supply by ECO12VDC max 450 Ohm(Connect to other devices by passive input and preferably insulated)
K15A/250V
K25A/250V
9 P10kPamax
C11a
WIRING DIAGRAM
BPB
TECHNICAL CHARACTERISTICS
Interval time 0,5 to 45 minutes, adjustable
Activation time 20 to 300 ms, adjustable
Manual adjustment by micro-switch
Supply voltage range 24 to 240 VAC/DC 50/60Hz
Current consumption 4 mA max
Working temperature -40°C ÷ +60°C
Protection level IP65
Enclosure material ABS plastic FR grade
Connection type EN175301-803 (ex DIN 43650A)
Indicators ON/OFF indication by LEDs
Standard design VDE 01 10C
ELECTRONIC SINGLE TIMER
TCONTEMP
TURBONET BUS SYSTEM CONTROLS - Up to 144 Valves
Connection to master controller by a single 3-core cable
TECHNICAL CHARACTERISTICS
T-RCP Series
Fluid Filtered and oilfree compressed air
Operating pressure Min 0,5 bar - max 7,5 bar
Temperature range -20°C +80°C
Base and cover Die cast aluminium
Core tube Stainless steel
Plunger Stainless steel
Screws Stainless steel
Coil insulation Class H
Protection IP66
Standar voltage 24V DC
MASTER WITH ∆P CONTROLLER
Enclosure IP65
Dimensions (mm) 160x137x103
Temperature -10°C +70°C
Power inlet 110/220 AC
Power outlet 24DC
One time 0,05 ÷5 sec
Off time 1 ÷ 999 sec
∆P 10kPa
End cycle cleaning
Hour counter
Display multilanguage
Set start / Stop cleaning cycle
Alarm max ∆P
Master generator
3 Wires cables
T- RCPPilot box
TurboNet master controller has been designed tocontrol cleaning cycle in dust collector filter appli-cations. It features digital differential pressure con-trol by internal transducer and provides effectivecost reduction in electrical wiring procedures. It isa microprocessor operated system with electricalzero connected to ground which ensures highimmunity to external interference and low fieldemissions. Max 2 output relays and 2 volt free digital inputs.
TURBONET BUS SYSTEM CONTROLS - Up to 144 Valves
Connection to master controller by a single 3-core cable
T-RCP Series
MASTER WITH ∆P CONTROLLER
TECHNICAL CHARACTERISTICS
Connectors Up to 12 per single belt
Cable diameter 8 mm
Protection IP65
Temperature range -20°C / +80°C
Matrix System is designed to reduce time and cost of wiring instal-lation.Matrix require a simple connection to the sequencer and to pulsevalve.
FEATURES
Matrix consist in moulded prewired connectors for pulse valve
Turbo provide Matrix connectors with desired pitch between valves.
Is compatible with any sequence controller available from the mar-
ket.
Matrix can be supplied factory plugged to pulse valves on the
header tank
MATRIX WIRING SYSTEM
HOW TO ORDER
M3
No.° of Connectors
Pitch (mm)
Conduit lenght tosequencer
Terminal:
•plugged
•free wires
MATRIX 4 P200 Plugged
MATRIX WIRING SYSTEM
97
TECHNICAL FEATURES
Power supply supply voltage 16 ÷ 24 VDC 100mA
Output signal 4 ÷ 20mA activ
Maximum load 350 Ohm
Gas temperature 120°C (standard)
Operating temperature -10° ÷ +50°C
Relative humidity 80%
Housing degree protections IP65
DESCRIPTION
The TC probe surveys the passage of par-
ticles present in the gas, converting this
physical phenomenon in an electric signal
proportional to the dustiness degree. By
comparing the signal generated by TC with
preset thresholds in proper devices, it is
possible to activate an alarm at the desi-
red value. If the cause of the alarm is due
to a broken bag, this can be identified
if it is connected to proper devices belon-
ging to ECO series which are envisaged
for this kind of control.
DUST EMISSION PROBE
TC SeriesTC
TECHNICAL FEATURES
Emission control by connecting a Tribo-Check Probe
High emission pre-alarm with relay contact open in alarm and automatic reset
High emission alarm with relay contact open in alarm and automatic reset
TC Probe signal zero adjust
Emission value set in mg/m3
TC Probe reading meaning time
TC Probe signal reading in mA
Double terminal on the board 2,5 mm2 250V 12A
Multi language display
OPTIONS ON REQUEST
Cable glands type & Q.ty on request
Other enclosures available on request
DESCRIPTION
Device designed to show and check the
signal from Tribo-Electric probe to mea-
sure the quantity of dust in a duct with
gas flow.
DUST EMISSION PROBE CONTROLLER
DTC Series DTC
ISO 9001:2008 certificated
NOTE
TURBO srlvia Po, 33
20811 CESANO MADERNOMB (ITALY)
phone ++39 0362 574024fax ++39 0362 [email protected]
©- All rights reserved. Design and specifications are subject to change without noticeCAT.HT_VALV 10/011 engl
™
® ®