TUBULAR & ÜBER FONTS WITH ECOBOILER UNDERCOUNTER WATER … · • Ensure water valve is on. •...

3
REQUIRED ECOBOILER UC4 1000740 ECOBOILER UC10 1000741 ECOBOILER UC45 1000744 • 4, 10, or 45 litre options • Portion dispense option NAME 0RDER CODE POWER @ 230V IMMEDIATE DRAW OFF CUPS (180ml) PER HOUR DIMENSIONS (D x W x H mm) PLUMBING REQS Ecoboiler UC4 1000740 2.4kW 4 L 133 395 x 135 x 585 3/4” BSP Ecoboiler UC10 1000741 2.8kW 10 L 156 395 x 228 x 585 3/4” BSP Ecoboiler UC45 1000744 5.6kW 45 L 311 495 x 420 x 667 3/4” BSP BOILERS FONTS NAME ORDER CODE DIMENSIONS (D x W x H mm) TAP TO COUNTER (T mm) Tubular Font 1000584 114 x 50 x 303 156 Tubular Font with Drip Tray 1000585 175 x 125 x 303 140 NAME ORDER CODE DIMENSIONS (D x W x H mm) TAP TO COUNTER (T mm) Über Font 1000811 470 x 250 x 400 295 Low Profile Über Font 1000811L 470 x 250 x 272 172 TUBULAR FONT 1000584 TUBULAR FONT WITH DRIP TRAY 1000585 DIMENSIONS Up to 3 fonts can be used on a single boiler (UC45 only) Quick and easy service for high volume environments ÜBER FONT 2 BUTTON 1000811 DIMENSIONS DIMENSIONS (LOW PROFILE) • Available in two heights • Can be used with 1 or 2 undercounter boilers H D W T H D W T H D W T SEE TABLE FOR PRODUCT DIMENSIONS PACKAGING NAME ORDER CODE PACKED WEIGHT PACKAGING DIMENSIONS (L x W x H mm) QUANTITY PER PALLET Ecoboiler UC4 1000740 11kg 500 x 240 x 690 10 Ecoboiler UC10 1000741 12.5kg 500 x 240 x 690 10 Ecoboiler UC45 1000744 22kg 500 x 420 x 690 4 Tubular Font 1000584 2.4kg 240 x 140 x 340 32 Tubular Font with Drip Tray 1000585 2.4kg 240 x 140 x 340 24 Über Font 1000811 7kg 490 x 280 x 670 16 Low Profile Über Font 1000811L 7kg 490 x 280 x 670 16 ASSOCIATED PRODUCTS ( SOLD SEPARATELY ) OR OR TUBULAR & ÜBER FONTS WITH ECOBOILER UNDERCOUNTER WATER BOILERS

Transcript of TUBULAR & ÜBER FONTS WITH ECOBOILER UNDERCOUNTER WATER … · • Ensure water valve is on. •...

Page 1: TUBULAR & ÜBER FONTS WITH ECOBOILER UNDERCOUNTER WATER … · • Ensure water valve is on. • Plug boiler appropriate electrical supply and press power button on the front of the

REQUIRED

ECOBOILER UC41000740

ECOBOILER UC101000741

ECOBOILER UC451000744

• 4,10,or45litreoptions• Portion dispense option

NAME0RDER CODE

POWER @ 230V

IMMEDIATE DRAW OFF

CUPS (180ml) PER HOUR

DIMENSIONS (D x W x H mm)

PLUMBING REQS

Ecoboiler UC41000740 2.4kW 4 L 133 395 x 135 x 585 3/4” BSP

Ecoboiler UC101000741 2.8kW 10 L 156 395 x 228 x 585 3/4” BSP

Ecoboiler UC451000744 5.6kW 45 L 311 495 x 420 x 667 3/4” BSP

BO

ILER

SFO

NTS NAME

ORDER CODEDIMENSIONS

(D x W x H mm)TAP TO COUNTER

(T mm)

Tubular Font1000584 114 x 50 x 303 156

Tubular Font with Drip Tray 1000585 175 x 125 x 303 140

NAMEORDER CODE

DIMENSIONS (D x W x H mm)

TAP TO COUNTER (T mm)

Über Font1000811 470 x 250 x 400 295

Low Profile Über Font1000811L 470 x 250 x 272 172

TUBULAR FONT1000584

TUBULAR FONT WITH DRIP TRAY1000585

DIMENSIONS

• Up to 3 fonts can be used on a single boiler (UC45 only)

• Quick and easy service for high volume environments

ÜBER FONT 2 BUTTON 1000811

DIMENSIONSDIMENSIONS (LOW PROFILE)

• Available in two heights

• Canbeusedwith1or2undercounterboilers

H

D

W

T

H

DW

TH

D

W

T

SEE TA

BLE FO

R

PR

OD

UC

T DIM

ENS

ION

S

PAC

KAG

ING

NAMEORDER CODE

PACKED WEIGHT

PACKAGING DIMENSIONS

(L x W x H mm)

QUANTITY PER

PALLET

Ecoboiler UC41000740 11kg

500x240x690

10

Ecoboiler UC101000741 12.5kg

500x240x690

10

Ecoboiler UC451000744 22kg

500x420x690

4

Tubular Font1000584 2.4kg

240x140x340

32

Tubular Font with Drip Tray 1000585 2.4kg

240x140x340

24

Über Font1000811 7kg

490x280x670

16

Low Profile Über Font 1000811L 7kg

490x280x670

16

ASS

OC

IATE

D P

ROD

UC

TS ( S

OLD

SEP

ARA

TELY

)

OR OR

TUBULAR & ÜBER FONTS WITH ECOBOILER UNDERCOUNTER WATER BOILERS

Page 2: TUBULAR & ÜBER FONTS WITH ECOBOILER UNDERCOUNTER WATER … · • Ensure water valve is on. • Plug boiler appropriate electrical supply and press power button on the front of the

TUBULAR FONT WITH ECOBOILER UC4, UC10 & UC45

COUNTER CUT-OUT

TUBULAR FONT 1000584TUBULAR FONT WITH DRIP TRAY 1000585

ECOBOILER UC4 1000740

ECOBOILER UC10 1000741

ECOBOILER UC45 1000741

VENTILATION REQUIREMENTS 50mm/1.9”clearancerequiredateachsideandbackofmachineifinstalledinanenclosedcabinet.

ELECTRICAL INSTALLATION PROCEDUREWheninstallingthemachine,alwaysobservethelocalregulationsandstandards.ThestandardmachineissuppliedwithaUK3-pinplug.ForEUmodelsa2-pinCEE-7plugwillbesupplied.USmodelswillbesuppliedwiththesuitableplug.Asuitablemainspowersupplysocketshouldbeavailablewithineasyaccessoftheappliancesothatitcanbedisconnectedeasilyafterinstall.ThewiresfromthefontareterminatedinaMiniFitconnectorwhichwillplugintoasimilarMiniFitconnectormountedonthetoplidoftheundercounterboiler.

PLUMBING INSTALLATION PROCEDURE• Ensurethattheequipmentisinstalledaccordingtolocal

plumbing&waterregulations.

• Mainswaterpressurerequired(limits):14.5-145psi(100-1000kPa,0.1-1MPa).

• Requiresinlinewaterfilterwithinyourwaterspecifications.

• Themachineissuppliedwitha3/4“BSPconnection.

• Turnonthewatertoflushanyimpurities,dustetcfromtheinlethoseandwaterpipe.Allowseverallitresthrough.Especiallyfornewinstallations.Connectthehosetotheinletvalveoftheboiler.Makesureasealingwasherisfitted.

• Turnonwaterandcheckforleaks.

• Iffontdoesnotofferaventconnection(TubularFontonly)thenonnoaccountmustVent/Overflowbe

connecteddirecttoadrain,ifconnectedtoadrainyouMUSTuseaTundishorEnsureanairbreakfailuretodothiswillresultinboilercontamination.

• Thisequipmentmustbeinstalledwithadequatebackflowprotectiontocomplywithallapplicablefederal,stateandlocalcodes.

OPERATING BOILER FOR THE FIRST TIME• Checkthatallinstallationprocedureshavebeen

carriedout.

• Ensurewatervalveison.

• Plugboilerappropriateelectricalsupplyandpresspowerbuttononthefrontofthemachinemarked‘Power’.

• The“poweron”lightwillglowgreenandthemachinewillfilltoasafelevel,abovetheelements,beforeheating.

• The“Ready/Status”lightwillcycletworedflasheswhilethemachineisfillingtothesafelevel.

• Whilstthemachineisabovethesafelevelandfilling,the“Ready/Status”lightwillremainblank.

• The“Ready/Status”lightwillglowgreenwhenthemachineisbothfullanduptonormaloperatingtemperature.

• Theboilerisnowreadyforuse.

• Thefontissimplyactivatedbypressingthebuttononthetopofthefont.

NOTE:Becausetheboileriselectronicallycontrollednoprimingisnecessary.Theelementcannotswitchonuntilasafelevelofwaterisreached.

2”/50mm*

2”/50mm

* Required for ventilation if the machine is installed

in an enclosed cabinet.

* Hosing should be trimmed to ensure continuous drop from font to boiler

23”/

585m

m

>27.

6”/7

00m

m

15.5”/395mm2”/50mm

11.9

”/30

3mm

4.5”/114mm Ø 1.3”/32mm

Water Power

Vent

Boiler Connections to Font

6.3”/161mm

min 5.1”/130mm

6.1”/156mm

23”/

585m

m

15.5”/395mm2”/50mm

11.9

”/30

3mm

* Hosing should be trimmed to ensure continuous drop from font to boiler

4.5”/114mm Ø 1.3”/32mm

Boiler Connections to Font

Water Power Vent

2”/50mm*

2”/50mm

* Required for ventilation if the machine is installed

in an enclosed cabinet.

>27

.6”/

700m

m

min 5.1”/130mm*

6.1”

/15

6mm

TUBULAR FONT WITH ECOBOILER UNDERCOUNTER WATER BOILERS

2”/50mm*

2”/50mm

* Required for ventilation if the machine is installed

in an enclosed cabinet.

* Hosing should be trimmed to ensure continuous drop from font to boiler

23”/

585m

m

>27.

6”/7

00m

m

15.5”/395mm2”/50mm

11.9

”/30

3mm

4.5”/114mm Ø 1.3”/32mm

Water Power

Vent

Boiler Connections to Font

6.3”/161mm

min 5.1”/130mm

6.1”/156mm 5.

5”/1

40m

m

* Required for ventilation if the machine is installed

in an enclosed cabinet.

26.2

”/66

7mm

19.4”/495mm2”/50mm

11.9

”/303

mm

* Hosing should be trimmed to ensure continuous drop from font to boiler

4.5”/114mm

6.3”/161mm

Ø 1.3”/32mm

Boiler Connections to Font

Dispense 1

Font #1 Connection

Vent

Dispense 22”/50mm*

2”/50mm

min

5.1

”/13

0mm

6.1”/156mm 5.

5”/1

40m

m

2”/50mm*

2”/50mm

* Required for ventilation if the machine is installed

in an enclosed cabinet.

* Hosing should be trimmed to ensure continuous drop from font to boiler

23”/

585m

m

>27.

6”/7

00m

m

15.5”/395mm2”/50mm

11.9

”/30

3mm

4.5”/114mm Ø 1.3”/32mm

Water Power

Vent

Boiler Connections to Font

6.3”/161mm

min 5.1”/130mm

6.1”/156mm 5.

5”/1

40m

m

Page 3: TUBULAR & ÜBER FONTS WITH ECOBOILER UNDERCOUNTER WATER … · • Ensure water valve is on. • Plug boiler appropriate electrical supply and press power button on the front of the

ÜBER FONT WITH ECOBOILER UC4, UC10 & UC45

COUNTER CUT-OUT

ÜBER FONT 1000811

ECOBOILER UC4 1000740

ECOBOILER UC10 1000741

ECOBOILER UC45 1000741

VENTILATION REQUIREMENTS 50mm/1.9” clearance required at each side and back of machine if installed in an enclosed cabinet.

ELECTRICAL INSTALLATION PROCEDUREWhen installing the machine, always observe the local regulations and standards. The standard machine is supplied with a UK 3-pin plug. For EU models a 2-pin CEE-7 plug will be supplied. US models will be supplied with the suitable plug. A suitable mains power supply socket should be available within easy access of the appliance so that it can be disconnected easily after install. The wires from the font are terminated in a Mini Fit connector which will plug into a similar Mini Fit connector mounted on the top lid of the undercounter boiler.

PLUMBING INSTALLATION PROCEDURE• Ensure that the equipment is installed according to local

plumbing & water regulations.

• Mains water pressure required (limits): 14.5 - 145psi (100 - 1000kPa, 0.1 - 1MPa).

• Requires inline water filter within your water specifications.

• The machine is supplied with a 3/4“ BSP connection.

• Turn on the water to flush any impurities, dust etc from the inlet hose and water pipe. Allow several litres through. Especially for new installations. Connect the hose to the inlet valve of the boiler. Make sure a sealing washer is fitted.

• Turn on water and check for leaks.

• If font does not offer a vent connection (Tubular Font only) then on no account must Vent/Overflow be

connected direct to a drain, if connected to a drain you MUST use a Tundish or Ensure an air break failure to do this will result in boiler contamination.

• This equipment must be installed with adequate backflow protection to comply with all applicable federal, state and local codes.

OPERATING BOILER FOR THE FIRST TIME• Check that all installation procedures have been

carried out.

• Ensure water valve is on.

• Plug boiler appropriate electrical supply and press power button on the front of the machine marked ‘Power’.

• The “power on” light will glow green and the machine will fill to a safe level, above the elements, before heating.

• The “Ready/Status” light will cycle two red flashes while the machine is filling to the safe level.

• Whilst the machine is above the safe level and filling, the “Ready/Status” light will remain blank.

• The “Ready/Status” light will glow green when the machine is both full and up to normal operating temperature.

• The boiler is now ready for use.

• The font is simply activated by pressing the button on the top of the font.

NOTE: Because the boiler is electronically controlled no priming is necessary. The element cannot switch on until a safe level of water is reached.

23”/

585m

m

15.5”/395mm2”/50mm

11.9

”/30

3mm

* Hosing should be trimmed to ensure continuous drop from font to boiler

4.5”/114mm Ø 1.3”/32mm

Boiler Connections to Font

Water Power Vent

2”/50mm*

2”/50mm

* Required for ventilation if the machine is installed

in an enclosed cabinet.

>27

.6”/

700m

m

min 5.1”/130mm*

6.1”

/15

6mm

23”/

585m

m

>27.

6”/7

00m

m

15.5”/395mm2”/50mm

15.7

”/40

0mm

11.6”/295mm

18.5”/470mm

Front of Font

14.6”/370mm

6.5”/165mm

Water Power

Vent

Boiler Connections to Font

min 5.1”/130mm*

* Hosing should be trimmed to ensure continuous drop from font to boiler

2”/50mm*

2”/50mm

* Required for ventilation if the machine is installed

in an enclosed cabinet.

23”/

585m

m

>27

.6”/

700m

m

15.5”/395mm2”/50mm

15.7

”/40

0mm

11.6

”/29

5mm

18.5”/470mm

Front of Font

14.6”/370mm

6.5”

/165

mm

Boiler Connections to Font

Water Power Vent

min 5.1”/130mm*

* Hosing should be trimmed to ensure continuous drop from font to boiler

2”/50mm*

2”/50mm

* Required for ventilation if the machine is installed

in an enclosed cabinet.

Front of Font

14.6”/370mm

6.5”/165mm

Boiler Connections to Font

Dispense 1

Font #1 Connection

Vent

Dispense 2

Font #2 Connection

19.4”/495mm2”/50mm

26.2

”/66

7mm

min

5.1

”/13

0mm

15.7

”/40

0mm

11.6”/295mm

* Hosing should be trimmed to ensure continuous drop from font to boiler

18.5”/470mm

23”/

585m

m

>27.

6”/7

00m

m

15.5”/395mm2”/50mm

15.7

”/40

0mm

11.6”/295mm

18.5”/470mm

Front of Font

14.6”/370mm

6.5”/165mm

Water Power

Vent

Boiler Connections to Font

min 5.1”/130mm*

* Hosing should be trimmed to ensure continuous drop from font to boiler

ÜBER FONT WITH ECOBOILER UNDERCOUNTER WATER BOILERS